CHROMA METER CR 400/410 400 Cr400 Catalog Eng

User Manual: 400

Open the PDF directly: View PDF PDF.
Page Count: 5

CHROMA METER
SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument.
Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock.
BHBPK
Printed in Japan9242-4889-11
©2002-2017 KONICA MINOLTA, INC.
25
CR
-400/410
CR-400
CR-410
217
40.2
32
100
255
73
Data Processor DP-400
Measuring Head CR-400 Measuring Head CR-410
Dimensions (Units: mm)Specifications
Color Data Software CM-S100w
SpectraMagicTM NX
CR-400 Utility Software
CR-S4w
White Calibration Plate
CR-A43
White Calibration Plate
CR-A44
Protective Cap
CR-A72
Protective Cap
CR-A104
RS-232C Cable
CR-A101(Head-DP)
RS-232C Cable
CR-A102(for PC)
AC Adapter
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Hard Case
CR-A103
Roll Paper (one roll)
Roll Paper
DP-A22(five rolls)
4 AA Size Batteries
4 AAA Size Batteries
Glass Light-Projection Tube
CR-A33a/f
Light-Projection Tube
CR-A33c/d
Glass Light-Projection Tube
CR-A33e
Granular-Materials Attachment
CR-A50
Pivoting Base
CR-A12
Color Tiles
Standard accessory
Optional accessory
Measuring Head
CR-400
Measuring Head
CR-410
Data Processor
DP-400
Standard/Optional
accessories
CR-400 Utility Software CR-S4w
To take measurements or change the
measurement parameters of the CR-
400/410 Series, you can control the
unit with a PC.
Measurement data can be transferred
directly to a Microsoft Excel®file by
means of the OLE function.
(Excel®97/2000/2002/2007 is required to use the Excel®transfer function.)
Calibration data and color-difference
reference color data can be uploaded
or modified.
System requirements
OS: Windows®7 Professional 32-bit, 64-bit
Windows®8.1 Pro 32-bit, 64-bit
Windows®10 Pro 32-bit, 64-bit
The hardware of the computer system to be
used must meet or exceed the greater of the
recommended system requirements for the
compatible OS being used or the following
specifications.
CPU: Pentium®166MHz or higher
Memory: 32MB or higher
Hard disk: 100MB or more free space
Display resolution:
VGA (640×480) or higher
Granular-Materials Attachment
CR-A50
With the Granular-Materials Attachment
CR-A50, the color of powders, pastes,
grains, and other granular substances can
be easily and accurately measured.
Glass Light-Projection Tube
CR-A33f (For CR-400) and CR-A33e (For CR-410)
Glass Light-Projection Tube CR-A33f and CR-A33e
have a glass plate at the tip and can be used for
measuring wet surfaces or for ensuring that
materials such as textiles are flat during measurements.
Pivoting Base CR-A12 (For CR-400)
Attaching the Pivoting Base CR-A12 to the
Measuring head of the CR-400 ensures greater
stability and accuracy in measurements Light-
Projection Tube CR-A33c is also included.
63 102 63 102
67.5
244
32
Name Data Processor
Model DP-400
Display range Y : 0.01 to 160.00% (reflectance)
Measurement time
21 Seconds.
Minimum measurement interval
23 Seconds.
Battery performance Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
Illuminant C, D65
Display Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
Tolerance judgment 2Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Colorimetric data/ XYZ, Y x y, Lab, Hunter Lab, LCh, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
indexes LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six registered in the Measuring Head can be used)
Languages Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
Data memory Max. 2,000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Color difference target colors
2Only for the operating function (100 pieces of data when the measuring head is connected; input of
measurement values or numeric) (independent of page function)
Calibration channels
2Only for the operating function (20 channels when the measuring head is connected)
(ch00: white calibration; ch01 to ch19: user calibration)
Page function 100 pages
Display Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384 dot line thermal printer (
can also print graphs
) Automatically prints out all measurement results (
can be set not to print
)
Statistical function Maximum, minimum, average, and standard deviation
Automatic measurement
2Date and time display: year, month, day, hour, minute
Timer: 3seconds. to 99 minutes.
(Some measurement modes require more than 3 seconds.)
Interface RS-232C compliant Baud rate (bps) : 19,200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the measurement head
Power 4 AA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D) 100 x 73 x 255 mm
Weight Approx. 600g (not including batteries and paper)
Operation temperature/ 0 to 40
C
, relative humidity 85% or less (at 35
C)
with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40C, relative humidity 80% or less (at 31C) with no condensation
Storage temperature/humidity range
-20 to 40
C
, relative humidity 85% or less (at 35
C)
with no condensation
Other User calibration function (multi-calibration/manual calibration) 2, Measurements for automatic average
function, Print ON/OFF function. CR-400 measurement data import function 2, All color space print ON/OFF
function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display
color limit function, Remote mode (stored data output), Character input function (alphanumeric)
2indicates that part of or all functions are not available when the measurement head is not connected.
Name Chroma Meter Measuring Head
Model CR-400 Head CR-410Head
Illumination/viewing system
Diffuse illumination/0
viewing angle
Wide-area illumination/0viewing angle
(
Specular component included/Conforms
(Specular component included)
to JIS Z 8722 condition c standard.)
Detector Silicone photo cells (6)
Display range Y: 0.01 to 160.00% (reflectance)
Light source Pulsed xenon lamp
Measurement time 1 seconds.
Minimum measurement interval
3 seconds.
Battery performance Approx. 800 measurements
(when using batteries under company testing Konica Minolta's conditions)
Measurement/illumination area
φ8/φ11 φ50/φ53
Repeatability Within ΔE*ab0.07 standard deviation (when the white calibration plate
is measured 30 times at intervals of 10 seconds)
Inter-instrument ΔE*ab: within 0.6 ΔE*ab: within 0.8
agreement Average of 12 BCRA series II colors
Observer 2 degrees Closely matches CIE 1931 Standard Observers: ( x2λ, yλ, zλ)
Illuminant 1C, D65
Display 1Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgment
1Color difference tolerance (box tolerance and elliptical tolerance)
Colorimetric data/
XYZ, Y x y, L
a
b
, Hunter Lab, L
C
h, Munsell (only illuminant C), CMC(l:c), CIE1994, Lab99,
indexes
LCh99, CIE2000, CIE WI•Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages Operating keys : English
LCD : English (default)
(LCD : German, French, Italian, Spanish, Japanese) *1
Data memory 1,000 (measuring head and data processor save different data)
Color difference target colors
100
Calibration channels
*1 20 channels (ch00 : white calibration, ch01 to ch19 : user calibration)
Display
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface RS-232C compliant (for data processor/PC)
* Baud rate : 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
Power 4 AAA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D)
102 x 217 x 63 mm 102 x 244 x 63 mm
Weight Approx. 550g Approx. 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operation temperature/
0 to 40C, relative humidity 85% or less (at 35C) with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40C, relative humidity 80% or less (at 31C) with no condensation
Storage temperature/humidity range
-20 to 40C, relative humidity 85% or less (at 35C) with no condensation
Other LCD back light ON/OFF function (when ON, back light stays ON for 30
seconds after last key or measurement operation)
1indicates when connected to the Data Processor or when not set using the Data Processor or the optional software,
that some of the function are not available when the measuring head is not connected.
Optional Accessories
System Diagram
Standard accessories
Optional accessories
CR-410
CR-400
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Protective Cap
CR-A72
Protective Cap
CR-A104
AAA Size
Battery (x4)
Roll Paper
DP-A22
(five rolls)
RS232C Cable(for PC)
CR-A102
AA Size
Battery (x4)
RS232C Cable
(Head-DP)
CR-A101
White Calibration
Plate
CR-A43
Glass Light
Projection Tube
CR-A33a
(with convex glass) Glass Light-Projection
Tube
CR-A33e
Glass Light
Projection Tube
CR-A33f
(with concave glass)
Light
Projection Tube
CR-A33c
(no disc) Pivoting Base
CR-A12
(includes CR-A33c)
Light
Projection Tube
CR-A33d
(with φ22mm disc)
Granular-Materials
Attachment
CR-A50
Color Tiles
White Calibration
Plate
CR-A44
AC Adapter
DP-400
Measuring Head
Data Processor
CR-400 Utility
Software
CR-S4w
Hard Case
CR-A103
(includes one Roll Paper)
The specifications and appearance shown herein are subject to change without notice.
SpectraMagicTM NX
CM-S100w
SpectraMagicTMNX Supports Windows®Vista/7/8.1/10
Specifications
SpectraMagicTM NX enables you to perform comprehensive color inspection and analysis of
incoming raw materials, in process production, and outbound color critical goods and
materials in virtually any industry. With SpectraMagicTM NX you can insert digital images with
measured data. Measure samples in any of 8 universally accepted color spaces. Select from 16
illuminants, and up to 40 indices to determine specific color and appearance properties, such
as brightness, haze, yellowness, opacity and strength. You can even configure up to 8
customized color equations. Reports range from simple Pass/Fail to trend charts, histograms,
color plots, and spectral graphs. SpectraMagicTM NX comes with predefined templates, or you
can create your own templates. For illustrations and explanations to understanding color and
color measurement technology, there is a link to Konica Minolta's well known and respected
“Precise Color Communication”.
Color space
Index
Color
difference
equation
Observer
Illuminant
Graph
display
L*a*b*, L*C*h, Lab99, LCh99, XYZ, Hunter Lab,
Yxy, L*u'v', L*u*v*, Munsell, and their color
differences (excluding Munsell)
WI (CIE 1982, ASTM E313-73, Hunter, Berger,
Taube, Stensby, Ganz), Tint(Ganz), YI (ASTM
D1925-70, ASTM E313-73, ASTM E313-96,
DIN6167), WB (B ASTM E313-73), Standard
Depth (ISO 105.A06), RXRYRZ,
Gray scale(ISO 105.A05)
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00
(CIE 2000), ΔE99 (DIN99), ΔE (Hunter), CMC
(I:c), FMC-2, NBS 100, NBS 200
2Standard Observer
C, D65
L*a*b* absolute value, ΔL*a*b*
(color difference
distribution)
, Hunter Lab absolute value, Hunter
ΔLab
(color difference distribution)
, Trend chart and
histogram of each color space and color
difference equation, Pseudo Color display
PC
(commercially available)
System requirements
OS: Windows
®
Vista Business 32-bit, 64-bit
Windows
®
7 Professional 32-bit, 64-bit
Windows
®
8.1 Pro 32-bit, 64-bit
Windows
®
10 Pro 32-bit, 64-bit
The hardware of the computer system to be used must meet or
exceed the greater of the recommended system requirements
for the compatible OS being used or the following specifications.
CPU: Pentium
®
III 600 MHz equivalent or faster
Memory: 128 MB or more (256 MB or more recommended)
Hard disk: 450 MB or more of free space for installation
Display resolution: 1,024 x 768 dots or more/ 16-bit colors or more
Other: DVD-ROM drive (required for installation); one free
USB port for protection key; one free port (serial port
or additional USB port) for connection to instrument
when connecting via cable (or USB port for USB
Bluetooth
®
adapter when using a USB Bluetooth
®
adapter for performing communication with CM-700d
or CM-600d via Bluetooth
®
); Internet Explorer Version.
5.01 or later.
Windows®is a trademark or registered trademark of Microsoft
Corporation in the USA and other countries.
Pentium®is a trademark of Intel Corporation in the USA and
other countries.
Bluetooth®is a registered trademark of Bluetooth SIG, Inc. and
is used under license agreement.
When measuring
powders or pastes
When color control
is performed with
a customized
evaluation formula,
instead of the versatile
color system
When a compact
colorimeter
is needed in the field
When measurements
need to be printed
on-site for labeling
of samples
U
-E
E
N
W
d
U
T
p
li
CR-400
Measurement area Ø8mm
CR-410
Measurement area Ø50mm
Denotes a new feature not available with the previous CR-300/310 Series.
CR-400
Data Processor DP-400
CR-410
Introducing the successor to the Konica Minolta
C
R-300
/
310,
our best-sellin
g
colorimeter
g
lobally accepted as the standar
d
in a wide range of industries.
The measuring head can perform
measurement alone.
The measuring head is detachable from the data processor.
Now, you can take measurements directly with the head
alone. What's more, you can connect the measuring head
directly to a PC. Simply install our optional software, and
your PC can function as the data processor.
User-defined evaluation formulas
freely set up.
The CR-400 Series features a User Index function that
allows you to configure the evaluation formula and color-
calculation formula as desired. This feature is intended to
meet the needs of color-control applications in which
industry-specific or customized evaluation formulas are
used instead of the versatile color system and standard
evaluation formula such as L*a*b*.
(Settings can be configured via a PC with optional software installed.)
Abundant accessories applicable to
various materials.
A varied selection of accessories is available to
accommodate various types of targets including powder,
paste and opaque liquids.
Compact data processor incorpor-
ates a high-speed printer.
The compact, lightweight data processor is battery-
operated* and features a built-in high-speed printer. Its size
and weight are approximately one-half those of the
conventional DP-300 Series. In addition, the CR-400 Series
is designed with a detachable shoulder strap for easier
portability. *An AC adapter is included as a standard accessory.
Full data compatibility with the
CR-300/310 series
To ensure data compatibility, the CR-400 Series utilizes the
same illumination-viewing optical system as the
conventional CR-300/310 Series. As a result, those
upgrading from the preceding model can make full use of
their existing data.
Easy-to-understand the name on the buttons, ensure
smooth measurement and setting operations.
Achieves exceptional accuracy
Inter-instrument agreement : CR-400: 6E*ab within 0.6
CR-410: 6E*ab within 0.8
Repeatability : within 6E*ab 0.07
User calibration function ensures higher accuracy.
(Settings can be configured with the data processor or via a PC with optional software
installed.)
Color difference tolerance can be set to perform
PASS/WARN/FAIL
(Settings can be configured with the data processor or via a PC with optional software
installed.)
Offers a wider range of color systems than the CR-
300/310 Series.
The measuring head alone can store up to 1,000
measurements. When the data processor is connected,
up to 2,000 measurements can be stored.(The measuring
head can store up to 100 color-difference target colors with
or without the data processor connected.)
Capable of displaying color-difference graphs that
provide a visual representation of the color difference.
(When connected to data processor)
A simple, cellular-phone-type text entry system is
provided for entering the names of color-difference
target colors and calibration channels.
(When connected to data processor)
Features a large, easy-to-see LCD with a built-in
backlight.
The LCD offers six user-selectable languages for the
display mode, including English and Japanese.
(When connected to data processor)
Can be powered with rechargeable batteries for reduced
operating costs.
The CR-400/410 Series really shows its abilities in these applications.
When measuring
powders or pastes
When color control
is performed with
a customized
evaluation formula,
instead of the versatile
color system
When a compact
colorimeter
is needed in the field
When measurements
need to be printed
on-site for labeling
of samples
U
-E
E
N
W
d
U
y
T
p
li
CR-400
Measurement area Ø8mm
CR-410
Measurement area Ø50mm
Denotes a new feature not available with the previous CR-300/310 Series.
CR-400
Data Processor DP-400
CR-410
Introducing the successor to the Konica Minolta
C
R-300
/
310,
our best-sellin
g
colorimeter
g
lobally accepted as the standar
d
in a wide range of industries.
The measuring head can perform
measurement alone.
The measuring head is detachable from the data processor.
Now, you can take measurements directly with the head
alone. What's more, you can connect the measuring head
directly to a PC. Simply install our optional software, and
your PC can function as the data processor.
User-defined evaluation formulas
freely set up.
The CR-400 Series features a User Index function that
allows you to configure the evaluation formula and color-
calculation formula as desired. This feature is intended to
meet the needs of color-control applications in which
industry-specific or customized evaluation formulas are
used instead of the versatile color system and standard
evaluation formula such as L*a*b*.
(Settings can be configured via a PC with optional software installed.)
Abundant accessories applicable to
various materials.
A varied selection of accessories is available to
accommodate various types of targets including powder,
paste and opaque liquids.
Compact data processor incorpor-
ates a high-speed printer.
The compact, lightweight data processor is battery-
operated* and features a built-in high-speed printer. Its size
and weight are approximately one-half those of the
conventional DP-300 Series. In addition, the CR-400 Series
is designed with a detachable shoulder strap for easier
portability. *An AC adapter is included as a standard accessory.
Full data compatibility with the
CR-300/310 series
To ensure data compatibility, the CR-400 Series utilizes the
same illumination-viewing optical system as the
conventional CR-300/310 Series. As a result, those
upgrading from the preceding model can make full use of
their existing data.
Easy-to-understand the name on the buttons, ensure
smooth measurement and setting operations.
Achieves exceptional accuracy
Inter-instrument agreement : CR-400: 6E*ab within 0.6
CR-410: 6E*ab within 0.8
Repeatability : within 6E*ab 0.07
User calibration function ensures higher accuracy.
(Settings can be configured with the data processor or via a PC with optional software
installed.)
Color difference tolerance can be set to perform
PASS/WARN/FAIL
(Settings can be configured with the data processor or via a PC with optional software
installed.)
Offers a wider range of color systems than the CR-
300/310 Series.
The measuring head alone can store up to 1,000
measurements. When the data processor is connected,
up to 2,000 measurements can be stored.(The measuring
head can store up to 100 color-difference target colors with
or without the data processor connected.)
Capable of displaying color-difference graphs that
provide a visual representation of the color difference.
(When connected to data processor)
A simple, cellular-phone-type text entry system is
provided for entering the names of color-difference
target colors and calibration channels.
(When connected to data processor)
Features a large, easy-to-see LCD with a built-in
backlight.
The LCD offers six user-selectable languages for the
display mode, including English and Japanese.
(When connected to data processor)
Can be powered with rechargeable batteries for reduced
operating costs.
The CR-400/410 Series really shows its abilities in these applications.
SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument.
Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock.
BHBPK
Printed in Japan9242-4889-11
©2002-2017 KONICA MINOLTA, INC.
25
CHROMA METER
CR
-400/410
CR-400
CR-410
217
40.2
32
100
255
73
Data Processor DP-400
Measuring Head CR-400 Measuring Head CR-410
Dimensions (Units: mm)Specifications
Color Data Software CM-S100w
SpectraMagicTM NX
CR-400 Utility Software
CR-S4w
White Calibration Plate
CR-A43
White Calibration Plate
CR-A44
Protective Cap
CR-A72
Protective Cap
CR-A104
RS-232C Cable
CR-A101(Head-DP)
RS-232C Cable
CR-A102(for PC)
AC Adapter
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Hard Case
CR-A103
Roll Paper (one roll)
Roll Paper
DP-A22(five rolls)
4 AA Size Batteries
4 AAA Size Batteries
Glass Light-Projection Tube
CR-A33a/f
Light-Projection Tube
CR-A33c/d
Glass Light-Projection Tube
CR-A33e
Granular-Materials Attachment
CR-A50
Pivoting Base
CR-A12
Color Tiles
Standard accessory
Optional accessory
Measuring Head
CR-400
Measuring Head
CR-410
Data Processor
DP-400
Standard/Optional
accessories
CR-400 Utility Software CR-S4w
To take measurements or change the
measurement parameters of the CR-
400/410 Series, you can control the
unit with a PC.
Measurement data can be transferred
directly to a Microsoft Excel®file by
means of the OLE function.
(Excel®97/2000/2002/2007 is required to use the Excel®transfer function.)
Calibration data and color-difference
reference color data can be uploaded
or modified.
System requirements
OS: Windows®7 Professional 32-bit, 64-bit
Windows®8.1 Pro 32-bit, 64-bit
Windows®10 Pro 32-bit, 64-bit
The hardware of the computer system to be
used must meet or exceed the greater of the
recommended system requirements for the
compatible OS being used or the following
specifications.
CPU: Pentium®166MHz or higher
Memory: 32MB or higher
Hard disk: 100MB or more free space
Display resolution:
VGA (640×480) or higher
Granular-Materials Attachment
CR-A50
With the Granular-Materials Attachment
CR-A50, the color of powders, pastes,
grains, and other granular substances can
be easily and accurately measured.
Glass Light-Projection Tube
CR-A33f (For CR-400) and CR-A33e (For CR-410)
Glass Light-Projection Tube CR-A33f and CR-A33e
have a glass plate at the tip and can be used for
measuring wet surfaces or for ensuring that
materials such as textiles are flat during measurements.
Pivoting Base CR-A12 (For CR-400)
Attaching the Pivoting Base CR-A12 to the
Measuring head of the CR-400 ensures greater
stability and accuracy in measurements Light-
Projection Tube CR-A33c is also included.
63 102 63 102
67.5
244
32
Name Data Processor
Model DP-400
Display range Y : 0.01 to 160.00% (reflectance)
Measurement time
21 Seconds.
Minimum measurement interval
23 Seconds.
Battery performance Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
Illuminant C, D65
Display Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
Tolerance judgment 2Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Colorimetric data/ XYZ, Y x y, Lab, Hunter Lab, LCh, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
indexes LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six registered in the Measuring Head can be used)
Languages Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
Data memory Max. 2,000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Color difference target colors
2Only for the operating function (100 pieces of data when the measuring head is connected; input of
measurement values or numeric) (independent of page function)
Calibration channels
2Only for the operating function (20 channels when the measuring head is connected)
(ch00: white calibration; ch01 to ch19: user calibration)
Page function 100 pages
Display Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384 dot line thermal printer (
can also print graphs
) Automatically prints out all measurement results (
can be set not to print
)
Statistical function Maximum, minimum, average, and standard deviation
Automatic measurement
2Date and time display: year, month, day, hour, minute
Timer: 3seconds. to 99 minutes.
(Some measurement modes require more than 3 seconds.)
Interface RS-232C compliant Baud rate (bps) : 19,200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the measurement head
Power 4 AA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D) 100 x 73 x 255 mm
Weight Approx. 600g (not including batteries and paper)
Operation temperature/ 0 to 40
C
, relative humidity 85% or less (at 35
C)
with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40C, relative humidity 80% or less (at 31C) with no condensation
Storage temperature/humidity range
-20 to 40
C
, relative humidity 85% or less (at 35
C)
with no condensation
Other User calibration function (multi-calibration/manual calibration) 2, Measurements for automatic average
function, Print ON/OFF function. CR-400 measurement data import function 2, All color space print ON/OFF
function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display
color limit function, Remote mode (stored data output), Character input function (alphanumeric)
2indicates that part of or all functions are not available when the measurement head is not connected.
Name Chroma Meter Measuring Head
Model CR-400 Head CR-410Head
Illumination/viewing system
Diffuse illumination/0
viewing angle
Wide-area illumination/0viewing angle
(
Specular component included/Conforms
(Specular component included)
to JIS Z 8722 condition c standard.)
Detector Silicone photo cells (6)
Display range Y: 0.01 to 160.00% (reflectance)
Light source Pulsed xenon lamp
Measurement time 1 seconds.
Minimum measurement interval
3 seconds.
Battery performance Approx. 800 measurements
(when using batteries under company testing Konica Minolta's conditions)
Measurement/illumination area
φ8/φ11 φ50/φ53
Repeatability Within ΔE*ab0.07 standard deviation (when the white calibration plate
is measured 30 times at intervals of 10 seconds)
Inter-instrument ΔE*ab: within 0.6 ΔE*ab: within 0.8
agreement Average of 12 BCRA series II colors
Observer 2 degrees Closely matches CIE 1931 Standard Observers: ( x2λ, yλ, zλ)
Illuminant 1C, D65
Display 1Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgment
1Color difference tolerance (box tolerance and elliptical tolerance)
Colorimetric data/
XYZ, Y x y, L
a
b
, Hunter Lab, L
C
h, Munsell (only illuminant C), CMC(l:c), CIE1994, Lab99,
indexes
LCh99, CIE2000, CIE WI•Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages Operating keys : English
LCD : English (default)
(LCD : German, French, Italian, Spanish, Japanese) *1
Data memory 1,000 (measuring head and data processor save different data)
Color difference target colors
100
Calibration channels
*1 20 channels (ch00 : white calibration, ch01 to ch19 : user calibration)
Display
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface RS-232C compliant (for data processor/PC)
* Baud rate : 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
Power 4 AAA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D)
102 x 217 x 63 mm 102 x 244 x 63 mm
Weight Approx. 550g Approx. 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operation temperature/
0 to 40C, relative humidity 85% or less (at 35C) with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40C, relative humidity 80% or less (at 31C) with no condensation
Storage temperature/humidity range
-20 to 40C, relative humidity 85% or less (at 35C) with no condensation
Other LCD back light ON/OFF function (when ON, back light stays ON for 30
seconds after last key or measurement operation)
1indicates when connected to the Data Processor or when not set using the Data Processor or the optional software,
that some of the function are not available when the measuring head is not connected.
Optional Accessories
System Diagram
Standard accessories
Optional accessories
CR-410
CR-400
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Protective Cap
CR-A72
Protective Cap
CR-A104
AAA Size
Battery (x4)
Roll Paper
DP-A22
(five rolls)
RS232C Cable(for PC)
CR-A102
AA Size
Battery (x4)
RS232C Cable
(Head-DP)
CR-A101
White Calibration
Plate
CR-A43
Glass Light
Projection Tube
CR-A33a
(with convex glass) Glass Light-Projection
Tube
CR-A33e
Glass Light
Projection Tube
CR-A33f
(with concave glass)
Light
Projection Tube
CR-A33c
(no disc) Pivoting Base
CR-A12
(includes CR-A33c)
Light
Projection Tube
CR-A33d
(with φ22mm disc)
Granular-Materials
Attachment
CR-A50
Color Tiles
White Calibration
Plate
CR-A44
AC Adapter
DP-400
Measuring Head
Data Processor
CR-400 Utility
Software
CR-S4w
Hard Case
CR-A103
(includes one Roll Paper)
The specifications and appearance shown herein are subject to change without notice.
SpectraMagicTM NX
CM-S100w
SpectraMagicTMNX Supports Windows®Vista/7/8.1/10
Specifications
SpectraMagicTM NX enables you to perform comprehensive color inspection and analysis of
incoming raw materials, in process production, and outbound color critical goods and
materials in virtually any industry. With SpectraMagicTM NX you can insert digital images with
measured data. Measure samples in any of 8 universally accepted color spaces. Select from 16
illuminants, and up to 40 indices to determine specific color and appearance properties, such
as brightness, haze, yellowness, opacity and strength. You can even configure up to 8
customized color equations. Reports range from simple Pass/Fail to trend charts, histograms,
color plots, and spectral graphs. SpectraMagicTM NX comes with predefined templates, or you
can create your own templates. For illustrations and explanations to understanding color and
color measurement technology, there is a link to Konica Minolta's well known and respected
“Precise Color Communication”.
Color space
Index
Color
difference
equation
Observer
Illuminant
Graph
display
L*a*b*, L*C*h, Lab99, LCh99, XYZ, Hunter Lab,
Yxy, L*u'v', L*u*v*, Munsell, and their color
differences (excluding Munsell)
WI (CIE 1982, ASTM E313-73, Hunter, Berger,
Taube, Stensby, Ganz), Tint(Ganz), YI (ASTM
D1925-70, ASTM E313-73, ASTM E313-96,
DIN6167), WB (B ASTM E313-73), Standard
Depth (ISO 105.A06), RXRYRZ,
Gray scale(ISO 105.A05)
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00
(CIE 2000), ΔE99 (DIN99), ΔE (Hunter), CMC
(I:c), FMC-2, NBS 100, NBS 200
2Standard Observer
C, D65
L*a*b* absolute value, ΔL*a*b*
(color difference
distribution)
, Hunter Lab absolute value, Hunter
ΔLab
(color difference distribution)
, Trend chart and
histogram of each color space and color
difference equation, Pseudo Color display
PC
(commercially available)
System requirements
OS: Windows
®
Vista Business 32-bit, 64-bit
Windows
®
7 Professional 32-bit, 64-bit
Windows
®
8.1 Pro 32-bit, 64-bit
Windows
®
10 Pro 32-bit, 64-bit
The hardware of the computer system to be used must meet or
exceed the greater of the recommended system requirements
for the compatible OS being used or the following specifications.
CPU: Pentium
®
III 600 MHz equivalent or faster
Memory: 128 MB or more (256 MB or more recommended)
Hard disk: 450 MB or more of free space for installation
Display resolution: 1,024 x 768 dots or more/ 16-bit colors or more
Other: DVD-ROM drive (required for installation); one free
USB port for protection key; one free port (serial port
or additional USB port) for connection to instrument
when connecting via cable (or USB port for USB
Bluetooth
®
adapter when using a USB Bluetooth
®
adapter for performing communication with CM-700d
or CM-600d via Bluetooth
®
); Internet Explorer Version.
5.01 or later.
Windows®is a trademark or registered trademark of Microsoft
Corporation in the USA and other countries.
Pentium®is a trademark of Intel Corporation in the USA and
other countries.
Bluetooth®is a registered trademark of Bluetooth SIG, Inc. and
is used under license agreement.
SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument.
Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
Be sure to use the specified batteries. Using improper batteries may cause a fire or electric shock.
BHBPK
Printed in Japan9242-4889-11
©2002-2017 KONICA MINOLTA, INC.
25
CHROMA METER
CR
-400/410
CR-400
CR-410
217
40.2
32
100
255
73
Data Processor DP-400
Measuring Head CR-400 Measuring Head CR-410
Dimensions (Units: mm)Specifications
Color Data Software CM-S100w
SpectraMagicTM NX
CR-400 Utility Software
CR-S4w
White Calibration Plate
CR-A43
White Calibration Plate
CR-A44
Protective Cap
CR-A72
Protective Cap
CR-A104
RS-232C Cable
CR-A101(Head-DP)
RS-232C Cable
CR-A102(for PC)
AC Adapter
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Hard Case
CR-A103
Roll Paper (one roll)
Roll Paper
DP-A22(five rolls)
4 AA Size Batteries
4 AAA Size Batteries
Glass Light-Projection Tube
CR-A33a/f
Light-Projection Tube
CR-A33c/d
Glass Light-Projection Tube
CR-A33e
Granular-Materials Attachment
CR-A50
Pivoting Base
CR-A12
Color Tiles
Standard accessory
Optional accessory
Measuring Head
CR-400
Measuring Head
CR-410
Data Processor
DP-400
Standard/Optional
accessories
CR-400 Utility Software CR-S4w
To take measurements or change the
measurement parameters of the CR-
400/410 Series, you can control the
unit with a PC.
Measurement data can be transferred
directly to a Microsoft Excel®file by
means of the OLE function.
(Excel®97/2000/2002/2007 is required to use the Excel®transfer function.)
Calibration data and color-difference
reference color data can be uploaded
or modified.
System requirements
OS: Windows®7 Professional 32-bit, 64-bit
Windows®8.1 Pro 32-bit, 64-bit
Windows®10 Pro 32-bit, 64-bit
The hardware of the computer system to be
used must meet or exceed the greater of the
recommended system requirements for the
compatible OS being used or the following
specifications.
CPU: Pentium®166MHz or higher
Memory: 32MB or higher
Hard disk: 100MB or more free space
Display resolution:
VGA (640×480) or higher
Granular-Materials Attachment
CR-A50
With the Granular-Materials Attachment
CR-A50, the color of powders, pastes,
grains, and other granular substances can
be easily and accurately measured.
Glass Light-Projection Tube
CR-A33f (For CR-400) and CR-A33e (For CR-410)
Glass Light-Projection Tube CR-A33f and CR-A33e
have a glass plate at the tip and can be used for
measuring wet surfaces or for ensuring that
materials such as textiles are flat during measurements.
Pivoting Base CR-A12 (For CR-400)
Attaching the Pivoting Base CR-A12 to the
Measuring head of the CR-400 ensures greater
stability and accuracy in measurements Light-
Projection Tube CR-A33c is also included.
63 102 63 102
67.5
244
32
Name Data Processor
Model DP-400
Display range Y : 0.01 to 160.00% (reflectance)
Measurement time
21 Seconds.
Minimum measurement interval
23 Seconds.
Battery performance Approx. 800 measurements (when using batteries under company testing Konica Minolta's conditions)
Illuminant C, D65
Display Chroma values, color difference values, color difference graphs, PASS/WARN/FAIL display
Tolerance judgment 2Color difference tolerance (box tolerance and elliptical tolerance) Only for the display function
Colorimetric data/ XYZ, Y x y, Lab, Hunter Lab, LCh, Munsell (only illuminant C), CMC (l:c), CIE1994, Lab99,
indexes LCh99, CIE2000, CIE WI-Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six registered in the Measuring Head can be used)
Languages Operating keys : English, LCD : English (default), German, French, Italian, Spanish, Japanese
Data memory Max. 2,000 pieces of data (divisible into 100 pages)
Deletion and Undoing selected stored data (one piece of data or all data) are possible
Color difference target colors
2Only for the operating function (100 pieces of data when the measuring head is connected; input of
measurement values or numeric) (independent of page function)
Calibration channels
2Only for the operating function (20 channels when the measuring head is connected)
(ch00: white calibration; ch01 to ch19: user calibration)
Page function 100 pages
Display Dot-matrix LCD with back light (16 chars x 9 lines + 1 line for icon display) Contrast adjustment
Printer 384 dot line thermal printer (
can also print graphs
) Automatically prints out all measurement results (
can be set not to print
)
Statistical function Maximum, minimum, average, and standard deviation
Automatic measurement
2Date and time display: year, month, day, hour, minute
Timer: 3seconds. to 99 minutes.
(Some measurement modes require more than 3 seconds.)
Interface RS-232C compliant Baud rate (bps) : 19,200 fixed (when connected to PC)
When measuring head is connected baud rate is automatically set to that of the measurement head
Power 4 AA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D) 100 x 73 x 255 mm
Weight Approx. 600g (not including batteries and paper)
Operation temperature/ 0 to 40
C
, relative humidity 85% or less (at 35
C)
with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40C, relative humidity 80% or less (at 31C) with no condensation
Storage temperature/humidity range
-20 to 40
C
, relative humidity 85% or less (at 35
C)
with no condensation
Other User calibration function (multi-calibration/manual calibration) 2, Measurements for automatic average
function, Print ON/OFF function. CR-400 measurement data import function 2, All color space print ON/OFF
function, Data protection ON/OFF function. Back light ON/OFF function. Buzzer ON/OFF function. Display
color limit function, Remote mode (stored data output), Character input function (alphanumeric)
2indicates that part of or all functions are not available when the measurement head is not connected.
Name Chroma Meter Measuring Head
Model CR-400 Head CR-410Head
Illumination/viewing system
Diffuse illumination/0
viewing angle
Wide-area illumination/0viewing angle
(
Specular component included/Conforms
(Specular component included)
to JIS Z 8722 condition c standard.)
Detector Silicone photo cells (6)
Display range Y: 0.01 to 160.00% (reflectance)
Light source Pulsed xenon lamp
Measurement time 1 seconds.
Minimum measurement interval
3 seconds.
Battery performance Approx. 800 measurements
(when using batteries under company testing Konica Minolta's conditions)
Measurement/illumination area
φ8/φ11 φ50/φ53
Repeatability Within ΔE*ab0.07 standard deviation (when the white calibration plate
is measured 30 times at intervals of 10 seconds)
Inter-instrument ΔE*ab: within 0.6 ΔE*ab: within 0.8
agreement Average of 12 BCRA series II colors
Observer 2 degrees Closely matches CIE 1931 Standard Observers: ( x2λ, yλ, zλ)
Illuminant 1C, D65
Display 1Chroma values, color difference values, PASS/WARN/FAIL display
Tolerance judgment
1Color difference tolerance (box tolerance and elliptical tolerance)
Colorimetric data/
XYZ, Y x y, L
a
b
, Hunter Lab, L
C
h, Munsell (only illuminant C), CMC(l:c), CIE1994, Lab99,
indexes
LCh99, CIE2000, CIE WI•Tw (only illuminant D65), WI ASTM E313 (only illuminant C),
YI ASTM D1925 (only illuminant C), YI ASTM E313 (only illuminant C),
User index (up to six can be registered from computer)
Languages Operating keys : English
LCD : English (default)
(LCD : German, French, Italian, Spanish, Japanese) *1
Data memory 1,000 (measuring head and data processor save different data)
Color difference target colors
100
Calibration channels
*1 20 channels (ch00 : white calibration, ch01 to ch19 : user calibration)
Display
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
Interface RS-232C compliant (for data processor/PC)
* Baud rate : 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
Power 4 AAA size alkaline or Ni-MH batteries,
AC Adapter AC120V 50-60Hz (for N.America and Japan)
AC230V 50-60Hz (for worldwide except N.America)
Size (W x H x D)
102 x 217 x 63 mm 102 x 244 x 63 mm
Weight Approx. 550g Approx. 570g
(including 4 AAA size batteries and not including RS-232C cable)
Operation temperature/
0 to 40C, relative humidity 85% or less (at 35C) with no condensation
humidity range
Operating temperature/humidity range of products for North America : 5 to 40C, relative humidity 80% or less (at 31C) with no condensation
Storage temperature/humidity range
-20 to 40C, relative humidity 85% or less (at 35C) with no condensation
Other LCD back light ON/OFF function (when ON, back light stays ON for 30
seconds after last key or measurement operation)
1indicates when connected to the Data Processor or when not set using the Data Processor or the optional software,
that some of the function are not available when the measuring head is not connected.
Optional Accessories
System Diagram
Standard accessories
Optional accessories
CR-410
CR-400
Wrist Strap
CR-A73
Shoulder Strap
SS-01
Protective Cap
CR-A72
Protective Cap
CR-A104
AAA Size
Battery (x4)
Roll Paper
DP-A22
(five rolls)
RS232C Cable(for PC)
CR-A102
AA Size
Battery (x4)
RS232C Cable
(Head-DP)
CR-A101
White Calibration
Plate
CR-A43
Glass Light
Projection Tube
CR-A33a
(with convex glass) Glass Light-Projection
Tube
CR-A33e
Glass Light
Projection Tube
CR-A33f
(with concave glass)
Light
Projection Tube
CR-A33c
(no disc) Pivoting Base
CR-A12
(includes CR-A33c)
Light
Projection Tube
CR-A33d
(with φ22mm disc)
Granular-Materials
Attachment
CR-A50
Color Tiles
White Calibration
Plate
CR-A44
AC Adapter
DP-400
Measuring Head
Data Processor
CR-400 Utility
Software
CR-S4w
Hard Case
CR-A103
(includes one Roll Paper)
The specifications and appearance shown herein are subject to change without notice.
SpectraMagicTM NX
CM-S100w
SpectraMagicTMNX Supports Windows®Vista/7/8.1/10
Specifications
SpectraMagicTM NX enables you to perform comprehensive color inspection and analysis of
incoming raw materials, in process production, and outbound color critical goods and
materials in virtually any industry. With SpectraMagicTM NX you can insert digital images with
measured data. Measure samples in any of 8 universally accepted color spaces. Select from 16
illuminants, and up to 40 indices to determine specific color and appearance properties, such
as brightness, haze, yellowness, opacity and strength. You can even configure up to 8
customized color equations. Reports range from simple Pass/Fail to trend charts, histograms,
color plots, and spectral graphs. SpectraMagicTM NX comes with predefined templates, or you
can create your own templates. For illustrations and explanations to understanding color and
color measurement technology, there is a link to Konica Minolta's well known and respected
“Precise Color Communication”.
Color space
Index
Color
difference
equation
Observer
Illuminant
Graph
display
L*a*b*, L*C*h, Lab99, LCh99, XYZ, Hunter Lab,
Yxy, L*u'v', L*u*v*, Munsell, and their color
differences (excluding Munsell)
WI (CIE 1982, ASTM E313-73, Hunter, Berger,
Taube, Stensby, Ganz), Tint(Ganz), YI (ASTM
D1925-70, ASTM E313-73, ASTM E313-96,
DIN6167), WB (B ASTM E313-73), Standard
Depth (ISO 105.A06), RXRYRZ,
Gray scale(ISO 105.A05)
ΔE*ab (CIE 1976), ΔE*94 (CIE 1994), ΔE00
(CIE 2000), ΔE99 (DIN99), ΔE (Hunter), CMC
(I:c), FMC-2, NBS 100, NBS 200
2Standard Observer
C, D65
L*a*b* absolute value, ΔL*a*b*
(color difference
distribution)
, Hunter Lab absolute value, Hunter
ΔLab
(color difference distribution)
, Trend chart and
histogram of each color space and color
difference equation, Pseudo Color display
PC
(commercially available)
System requirements
OS: Windows
®
Vista Business 32-bit, 64-bit
Windows
®
7 Professional 32-bit, 64-bit
Windows
®
8.1 Pro 32-bit, 64-bit
Windows
®
10 Pro 32-bit, 64-bit
The hardware of the computer system to be used must meet or
exceed the greater of the recommended system requirements
for the compatible OS being used or the following specifications.
CPU: Pentium
®
III 600 MHz equivalent or faster
Memory: 128 MB or more (256 MB or more recommended)
Hard disk: 450 MB or more of free space for installation
Display resolution: 1,024 x 768 dots or more/ 16-bit colors or more
Other: DVD-ROM drive (required for installation); one free
USB port for protection key; one free port (serial port
or additional USB port) for connection to instrument
when connecting via cable (or USB port for USB
Bluetooth
®
adapter when using a USB Bluetooth
®
adapter for performing communication with CM-700d
or CM-600d via Bluetooth
®
); Internet Explorer Version.
5.01 or later.
Windows®is a trademark or registered trademark of Microsoft
Corporation in the USA and other countries.
Pentium®is a trademark of Intel Corporation in the USA and
other countries.
Bluetooth®is a registered trademark of Bluetooth SIG, Inc. and
is used under license agreement.

Navigation menu