INSTALLATION INSTRUCTIONS
P24957

Effective November 2010
Supersedes August 1999

E26 Stacklight
The E26 Stacklight provides a visual and/or audible status
indication. Plug-in light modules consist of a lens with a diffuser
for steady of flashing incandescent lamps or LEDs. Up to six color
modules provide signals with 360 degree visibility. Flashing xenon
tube lights and audible alarms are available.

WARNING

Mounting and NEMA - IEC Enclosure Type Ratings
Base Mounting - For use on a flat surface of Type 1, 4, 4X, and
13 enclosures (IP65).
Threaded 3/4” Conduit Mounting - Use with a Myers ST-2 or
ST-2CP hub, or suitable enclosure with threaded 3/4” NPT conduit entrance for Type 1, 4, 4X, and 13 enclosure ratings (IP65).
Alarm Unit - Enclosure Type 1 (IP20).

REMOVE POWER BEFORE DISASSEMBLING THE STACKLIGHT
OR CHANGING LAMPS. THESE INSTRUCTIONS MUST BE
READ AND CLEARLY UNDERSTOOD BEFORE INSTALLING OR
OPERATING THIS EQUIPMENT. THIS EQUIPMENT IS TO BE INSTALLED AND SERVICED BY A TRAINED ELECTRICIAN.

Mount the stacklight in the vertical position on a flat horizontal
surface.
Specifications
Lamp Type BA15d. 6 watts maximum
(See page 5 for C-H lamp replacement catalog numbers)
Operating Temperature Range -20oC to 60oC (-4oF to 140oF)
Operating Humidity 95% @ 40oC (104oF)
Storage Temperature -40oC to 80oC (-40oF to 176oF)
IEC Ratings
Compliance IEC60947-5-1, EN60947-5-1
Degree of Protection against Electrical Contact for
Stacklight IP2X
Degree of Protection against Electrical Contact for
Alarm Unit IP0X
Rated Insulation Voltage (Ui) 690V
Rated Operational Votlage (Ie) 250 max
Rated impulse withstand voltage (Uimp) 1.5Kv
Shock Resistance (IEC 68-2-27) Without vibration damper fitted 11ms, 15g
With vibration damper fitted 18ms, 30g
Vibration (IEC 68-2-6) Without vibration damper fitted 10 sweeps, 10-50Hxz, 2g
With vibration damper fitted 10 sweeps, 10-150Hz, 10g
Bump (IEC 68-2-29) Without vibration damper fitted 6ms duration, 1000 bumps, 15g
With vibration damper fitted 6ms duration, 1000 bumps, 25g
Fig. 1 Typical Stacklight Assembly (Exploded View)

INSTALLATION INSTRUCTIONS P24957

E26 Stacklight

Effective November 2010

Field Wiring
Remove the Terminal Board for Wiring
Squeeze the locking clips one side at a time and pull up on the
terminal board to disengage the locking tabs from the cutouts in
the stacklight base. Repeat this procedure for the other locking
clip. Lift the terminal board out of the stacklight base.
Connect Field Wiring to Terminal Blocks
Connect field wiring per diagrams below. Terminals accept wire
sizes 14AWG - 30AWG (2.5 sq mm - 0.05 sq mm) for single conductors and 18AWG to 26AWG (0.75 sq mm - 0.14 sq mm) for
two conductors. Do not mix solid and stranded wire in the same
terminal. Recommended tightening torque is 4.4 lb/in to 5.3 lb/
in (0.5Nm to 0.6 Nm). After wiring is complete, proceed to “Assembly” on Page 3.

Fig. 2

Use with incandescent lamps, convvtinuous LEDs,
flashing LEDs, alarm units, and xenon flashing units.

Fig. 3

Standard Boase (Continuous Lights)

???

Use with incandescent lamps only, up to maximum number per table

Fig. 4 Flashing Base

Continuous lights may be combined with flashing lights according to the wiring diagrams above.
2

EATON CORPORATION www.eaton.com

E26 Stacklight

INSTALLATION INSTRUCTIONS P24957
Effective November 2010

Assembly

MAXIMUM COMBINATIONS OF
STACKLIGHT MODULES

After wiring is complete, assemble light diffusers. While observing the orientation of the two guides, plug the light diffuser into
the terminal connections in the stacklight base or previous diffuser. See Fig. 4.

Incandescent
or LED
Modules

Xenon
Modules

Alarm
Modules*

Maximum
Numbr of
Modules

6

--

--

6

5

--

1

6

4

1

--

5

3

1

1

5

2

2

--

4

1

2

1

4

Assemble lenses and cover by turning clockwise to engage the
bayonets in the stacklight base or previous lens. See Fig. 5.

* Alarm must be the Top Module.

Guide

Fig. 5

Fig. 4

WARNING
TURN OFF POWER BEFORE INSTALLING ALARM

Drill 2 holes in stacklight base to 0.165” (4.2mm). Mount stacklight
with #8-32 (M4) screws. Tighten to torque of 7 lb/in (0.79 Nm).

Fig. 7

Mounting Dimensions for Stacklight Base

If an audible alarm is to be installed, connect the two leads from
the alarm to the terminal connections at the innermost points on
the connectors as shown in Fig. 6.

Without Vibration Damper: Mount stacklight with #8-32 (M4) screws.
Tighten to torque of 7 lb/in (0.79 Nm).
With Vibration Damper: Discard sealing washer. Mount stacklight with
#8-32 (M4 screws). Tighten to torque of 6 lb/in (0.68 Nm).

Fig. 6

Installing Alarm Unit

Fig. 7

Mounting Dimensions for Mounting Base
EATON CORPORATION www.eaton.com

3

INSTALLATION INSTRUCTIONS P24957

E26 Stacklight

Effective November 2010

Disasssembly and Lamp Replacement

WARNING
TURN OFF POWER BEFORE DISASSEMBLY!
Remove lens by turning counterlockwise to disengage the
bayonets.
Remove the light diffuser by pulling upwards to disengage the
clips.
Replace lamp and reassemble in reverse order.
E22BA3 lamp removal tool is available to aid in lamp removal and
installation.

Fig. 9 Threaded 3/4” NPT Conduit Mounting

Fig. 11 ???
INCANDESCENT LAMP
REPLACEMENT

Fig. 10 Assembled Stacklight Dimensions

Description

Catalog No.

12V (BA15d) 6 watts

E26S8

24V (BA15d) 6 watts

E26S9

48V (BA15d) 6 watts

E26S10

110/130V (BA15d) 6 watts

E26S11

220/240V (BA15d) 6 watts

E26S12

Eaton Corporation
Electrical Group
1000 Cherrington Parkway
Moon Township, PA 15108
United States
877-ETN-CARE (877-386-2273)
Eaton.com
© 2008 Eaton Corporation
All Rights Reserved
Printed in USA
Publication No. P24957 / 001
November 2010

PowerChain Management is a registered
trademark of Eaton Corporation.
All other trademarks are property of their
respective owners.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : E4088551
Create Date                     : 2010:12:01 15:28:26-04:00
Modify Date                     : 2010:12:01 15:28:26-04:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : E4088551
Title                           : P24957.indd
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.3.0 (Windows)
Document ID                     : uuid:ce6998ea-19fe-4cfc-8b44-cab8d6dead1a
Instance ID                     : uuid:245b4611-5137-4527-8a50-3c75210530a0
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu