595665J00_EN 400062 Electrolux Service Manual Dishwashing 11 20111
User Manual: 400062
Open the PDF directly: View PDF .
Page Count: 122
Download | ![]() |
Open PDF In Browser | View PDF |
Electrolux EFS - Dishwashing Systems Platform Electrolux Professional SERVICE MANUAL 3..__ TANK BOILER 3.__ CONTENTS: TANK BOILER This document contains the instructions to set electronic board parameters via user interface for following dishwashers: CODE MODEL CODE MODEL CODE MODEL CODE MODEL 400041 NUC3DD 502033 EUCAIG 504235 EHTAIAU 506052 ZPPWEHG 400055 EUC1 502034 EUCAIWSG 504236 EHTAIMLAU 506053 ZPPWSSG 400056 EUC1DP 502035 EUCAIML 504237 ZHTAWS 506054 EPPWELG 400057 EUC1WS 502036 EUCAIMLWS 504238 ZHTAID 506055 EPPWELG60 400058 EUC1DPWS 502037 EUCAIMLG 504239 ZHTAIWS 506056 ZPPWELG 400059 EUC3 502038 EUCAICL 504240 ZHTAIAU 506057 ZPPWSLG 400060 EUC3WS 502039 EUCAICLG 504241 ZHTA 690028 NUC1G 400061 EUC3DP 502040 EUCAIWL 504242 ZHTA60 698005 NUCA1DDG 400062 EUC3DPWS 502042 EUCAICLW 504243 ZHTAI 698047 OHTAROW 400063 EUC1G 502043 EUCI 504244 EHTAIUSPH5 698048 OHTAROW60 400064 EUC1DP60 502044 EUCIM 504245 EHTAIUSPH6 698083 APPWELG 400065 EUC3DD 502045 EUCIM60 505036 EHTAO 698085 APPWESG 400066 ZUCADDROW 502046 EUCAIDPNW 505046 EHT 698086 APPWEHG 400067 ZUCADDROW6 502047 ZUCI 505047 EHT60 698087 ET5AIIT 400116 FUCA3DD 502048 ZUCID 505048 EHTAG 698088 ET5AIDP 400127 KUC3 502049 ZUCAI 505049 EHTM 698089 ET5AIDPWS 400128 KUC3DP 502050 ZUCAIDP 505050 EHTM60 698091 AUCI 400140 NUC1 502051 ZUCAIDPWS 505051 NHT 698092 AUCAI 400141 NUC1DP 502052 ZUCAIG 505052 NHTD 698093 AUCAIDP 400142 NUC1WS 502053 ZUCAIDDWS 505053 NHT60 698094 AUCAIDPWS 400143 NUC1WSDP 502054 ZUCAID 505054 EHTAROW 698095 AUCAIG 400144 NUC3 502055 ZUCAI60 505055 EHTAROW60 698096 AUCAIWSG 400145 NUC3WS 502056 EUCAIUSPH6 505056 ZHTAROW 698097 ET12AI 400146 NUC3DP 502057 ZUCAIDD 505057 ZHTAROW60 698098 ET12AIT 400147 NUC3DPWS 502058 EUCAIDD 505058 EHTAJ 698110 NHTAG 400148 NUC3DDWS 502059 EUCAIDPJ 505059 EHTAJ60 698115 AHTAWS 400149 NUC1DP60 502060 EUCAIDPJ60 505060 EHTAO60 698116 AHTAIWS 400150 NUC1DPA 504226 EHTA 505061 ZHTAO 698117 AHTAIG 400151 ZUCA1 504227 EHTA60 505062 ZHTAO60 698118 AHTAIWSG 400152 ZUCA3 504228 EHTAWS 505063 KHT 698119 AHTA 400153 EUCADDROW 504229 EHTAI 505064 NHTM 698120 AHTAI 400154 EUCADDROW6 504230 EHTAID 505065 NHTM60 S49JGF 502025 EUCAI 504231 EHTAIWS 506048 EPPWESG S49LBN S49QL1 502026 EUCAIDP 504232 EHTAIDWS 506049 EPPWESG60 502027 EUCAI60 504233 EHTAIG 506050 EPPWEHG 502028 EUCAIWS 504234 EHTAIWSG 506051 ZPPWESG EDITION: DOC. NO. 5956.65J.00 11.2011 P. 1 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional INDEX 1 KEYBOARDS Pag. 3 1.1 HOOD TYPE Style Pag. 3 1.2 UNDERCOUNTER Style Pag. 4 MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS Pag. 5 2.1 Detergent Dispenser Activation Pag. 5 2.2 Rinse Aid Dispenser Activation Pag. 5 3 RINSE PUMP MANUAL ACTIVATION Pag. 5 4 DETERGENT AND RINSE AID DOSAGE Pag. 6 4.1 2 5 6 7 8 9 10 Pag. 6 COUNTERS GEn General Parameters Pag. 8 5.1 Pag. 8 Cnt Counters TEMPERATURE SETTING Pag. 10 6.1 Pag. 10 CYCLE SETTING Pag. 12 7.1 CYCLE DIAGRAM Pag. 13 7.2 CY1 Cycle 1 Parameters Pag. 14 7.3 CY2 Cycle 2 Parameters Pag. 14 7.4 CY3 Cycle 3 Parameters Pag. 14 7.5 drn Drain/Cleaning Cycle Parameters Pag. 15 OTHER PARAMETERS Pag. 15 8.1 dPA Dishwashing Parameters Pag. 15 8.2 ron Read Only Parameters Pag. 16 8.3 HCP Communication and HACCP Parameters Pag. 16 8.4 CFG Configuration Parameters Pag. 17 8.5 dbG Parameters for automatic hood type dishwashers FAC Factory Parameters Pag. 18 SPECIAL FEATURES Pag. 19 9.1 RESIN REGENERATION CYCLE Pag. 19 9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE Pag. 19 9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION Pag. 19 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER Pag. 20 9.5 HOOD-TYPE DISHWASHER WITH CYCLE THERMAL LABEL Pag. 21 9.6 DISHWASHERS WITH WASH CONTROL TANK WATER CHANGE FREQUENCY Pag. 21 MAIN BOARD CONFIGURATION Pag. 23 10.1 CODE -> Prog. TABLE Pag. 23 10.2 PROGRAMMING SHEETS Pag. 25 11 DEFAULT VALUES Pag. 105 12 USER INTERFACE AND MAIN BOARD CONNECTORS Pag. 108 12.1 Main malfunctions not due to the main board Pag. 108 12.2 CONNECTORS LAYOUT Pag. 108 13 ALARM MESSAGES AND TROUBLESHOOTING Pag. 115 13.1 ALARMS THAT STOP THE DISHWASHER Pag. 115 13.2 13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS ALARMS THAT DON'T STOP THE DISHWASHER Pag. Pag. 115 119 13.3 14 ALARMS THAT DON’T STOP THE DISHWASHER FOR MODELS WITH INCORPORATED CONTINUOUS WATER SOFTENER LIST OF PARAMETERS FOR SUBSEQUENT VERSIONS DOC. NO. 5956.65J.00 Pag. 121 Pag. 122 P. 2 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 1 KEYBOARDS 1.1 HOOD TYPE Style dEt Fig. 1 Detergent dispenser Manual Activation. rAi Fig. 2 Rinse Aid Dispenser Manual Activation --- Fig. 3 Rinse Pump Manual Activation (used to EMPTY BOILER) SETTING MODES: To enter into one setting mode (Figure 4),(Figure 5) the appliance should be in stand-by: switch on the appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure of the two keys. GEn Fig. 4 Enter into General Parameters (Hold down buttons for at least five seconds). 888 Fig. 6 Next Parameter Family OR Increase Parameter Value(In setting mode only) DOC. NO. 5956.65J.00 FAC Fig. 5 Enter into Factory Parameters (Hold down buttons for at least five seconds).. 888 Fig. 7 Decrease Parameter Value(In setting mode only) 888 Fig. 8 Confirm Value and go to next Parameter (In setting mode only). P. 3 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 1.2 UNDERCOUNTER Style dEt TANK BOILER Fig. 9 Detergent dispenser Manual Activation rAi TANK BOILER Fig. 10 Rinse Aid Dispenser Manual Activation --- TANK BOILER Fig. 11 Rinse Pump Manual Activation (used to EMPTY BOILER) SETTING MODES: To enter into one setting mode (Figure 12), (Figure 13) the appliance should be in stand-by: switch on the appliance, no cycles selected. Is useful keep door open to avoid start cycle in case of not simultaneously pressure of the two keys. DOC. NO. 5956.65J.00 GEn TANK BOILER Fig. 12 Enter into General Parameters (Hold down buttons for at least five seconds). FAC TANK BOILER Fig. 13 Enter into Factory Parameters (Hold down buttons for at least five seconds). 888 TANK BOILER Fig. 14 Next Parameter Family OR Increase Parameter Value (in setting mode only) 888 TANK BOILER Fig. 15 Decrease Parameter Value (In setting mode only) 888 TANK BOILER Fig. 16 Confirm Value and go to next Parameter (in setting mode only). P. 4 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 2 MANUAL ACTIVATION OF DETERGENT AND RINSE AID DISPENSERS When replacing detergents may be necessary activate the dispensers to fill hoses. 2.1 Detergent Dispenser Activation Switch on the dishwasher. Press and hold down CYCLE_2 and CYCLE INFINITE keys, after two 'beep' the detergent dispenser starts work for 20 sec. dEt 2.2 Rinse Aid Dispenser Activation Switch on the dishwasher. Press and hold down CYCLE_1 and CYCLE INFINITE keys, after two 'beep' the rinse aid dispenser starts work for 40 sec. rAi 3 RINSE PUMP MANUAL ACTIVATION Use this function to empty the boiler (if the dishwasher is not to be used for a long time, for maintenance operation: ex. before replacing main board). --- DOC. NO. 5956.65J.00 Switch on the dishwasher. Close the door and press and hold down DRAIN and CYCLE INFINITE keys. A buzzer signal indicates the rinse pump activation and the display shows three blinking lines. Three beeps indicate the cycle end. P. 5 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 4 DETERGENT AND RINSE AID DOSAGE In this paragraph is explained how to set the working time for the detergent and rinse aid dispensers. For each dispenser there are two parameters: the initial time and the time during cycle execution. 4.1 General Parameters Sym. Parameter Description Initial Detergent Dosage (during filling tank) [s] 0 240 90 Initial Rinse Aid Dosage (starts when tank filled) [s] 0 180 10 Detergent Dosage During Cycle Execution (during wash phase) Rinse Aid Dosage During Cycle Execution (when refilling boiler) [s] 0 182 (*) 8 [s] 0 62 (*) 4 Unit Min Max Factory Default How change the duration: • Switch OFF and switch ON the dishwasher; • Enter into the USER SETTING mode by pressing and hold down ON/OFF and CYCLE_1 keys for at least five seconds the display shows (Figure 17); • Press CYCLE_INFINITE. The display shows alternatively the symbol dIn and the duration in seconds (Figure 18) and (Figure 19) ; • NOTE: If User Interface v.3.00 tank led is on if value correspond to factory default ( Default 1 - HOOD TYPE). • Use CYCLE_1 key to decrease the duration and CYCLE_2 key to increase (Figure 19); • After settled the duration press CYCLE_INFINITE key to store value. The display shows the next parameter (Figure 20) and the corresponding value (Figure 21); • In the same way is possible to change the other duration; when finished switch OFF and switch ON. GEn Fig. 17 Enter into User Mode (press for 5 sec).. dIn Fig. 18 Initial detergent dosage. dEt Fig. 22 Cycle detergent dosage. DOC. NO. 5956.65J.00 90 Val.Fabbr. Fig. 19 Change duration. (Tank LED indicates default). 8 Val.Fabbr. Fig. 23 Change time activation (Tank LED indicates default) rIn Fig. 20 Initial rinse aid dosage rAi Fig. 24 Cycle rinse aid dosage. 24 Fig. 21 Change duration 7 Fig. 25 Change time activation. P. 6 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional (*) Note for external dispensers: • if the detergent dispenser works when WASHING PUMP is being activated; at the same time voltage is supplied between connectors L17–L19 (main terminal box); • if • if • if the detergent dispenser works when LOADING EV is being activated to re-fill boiler level; at the same time voltage is supplied between connectors L17–L19 (main terminal box); the rinse aid dispenser works when LOADING EV is being activated to re-fill boiler level; at the same time voltage is supplied between connectors L18–L19 (main terminal box); the rinse aid dispenser works when WASHING PUMP is being activated; at the same time voltage is supplied between connectors L18–L19 (main terminal box); - For electrical connections refer to electric diagram - Example Suppose there is connected an external detergent dispenser with a probe into the tank. A typical setting could be: the dispenser is not activated during filling tank; the dispenser is supplied during washing phase and the probe automatically dose the right detergent amount. DOC. NO. 5956.65J.00 P. 7 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 5 COUNTERS This Parameter Family collects cycle counters and water consumption counters. For water consumption counters a flow meter must be installed. See (calibration parameter) into section (8 OTHER PARAMETERS). 5.1 Counters Sym. Parameter Description Unit Min Max Factory Default Cycles performed counter. symbol and two numbers blink consecutively. The cycle number is obtained by joining the two numbers. Ex. - means 10042 cycles executed. Cycle counter (resettable). This counter is similar to parameter below). but is resettable by user (see Water Consumption (only for dishwashers with incorporated continuous water softener). Counts m3 of water consumption. Water Consumption (only for dishwashers with incorporated continuous water softener). Counts litres of water consumption. The total consumption is given by adding [m3] - [m3] [l] and [l] values. Water Consumption: resettable counter. [present up to software version 3.12] Counts the litres of water and is resettable by user (see parameter below). [l] Reset resettable counters: and and will show zero. Note that is used to count cycles for message (see next parameter, ). Store thousand of cycles after that message appears on dis- To reset put 1 this parameter, switch off and then on again: play. Ex. If this parameter is settled to 20, message appears when - - reach 20.000 cycles. Drain/Cleaning cycles performed. Similar to but counts Cleaning Cycles. - Numbers of cycles that can be made after a regeneration cycle (only for dishwashers with non-continuous water softener) [See paragraph 9.1 RESIN REGENERATION CYCLE.]. - Regeneration cycle counter (only for water softener dishwasher) [See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER]. only counts efficient regeneration cycles, i.e. those carried out with salt in the special container (only for dishwashers with incorporated continuous water softener) - Counter of regeneration cycles done without salt in the special container. (only for dishwashers with incorporated continuous water softener) [See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER]. - DOC. NO. 5956.65J.00 20 P. 8 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional GEn Fig. 26 USER setting mode (press for 5s). CYC Fig. 29 CYCLES DOC. NO. 5956.65J.00 GEn Fig. 27 Next Family 010 Fig. 30 Thousand. Cnt Fig. 28 Counters Fam.: ENTER 042 Fig. 31 Units. cYc Fig. 32 Next counter. P. 9 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 6 TEMPERATURE SETTING In this paragraph is explained how to change temperature thresholds and all parameters related to boiler and tank. 6.1 Factory Parameters Sym. Parameter Description Boiler Temperature: THRESHOLD. When boiler temperature reaches this value, heaters switch off. Boiler Temperature HISTERESIS, (represent dead band). Boiler Temperature: HIGH LIMIT. Heater switch on if boiler temperature is below: - When boiler temperature reaches this value alarm appears. Unit Min Max Factory Default [°C] 45 95 78 [°C] 2 10 2 [°C] 0 98 96 [°C] 0 10 1 [min] 0 42 5 [°C] 0 7 4 - 0 1 1 [°C] 0 15 2 [°C] 0 20 0 [°C] 40 85 63 [°C] 2 30 5 [°C] 0 95 75 [°C] 0 10 1 [min] 0 42 20 Put 0 to disable alarm. Boiler Temperature: LOW LIMIT. During boiler warm-up, temperature must increase at least °C otherwise warning appears. Put 0 to disable warning. Boiler Filling Timeout. If filling time is longer than , alarm appears. Put 0 to disable alarm. Boiler Temperature Adjust. Boiler Priority (enable boiler wait function) 0=disabled 1=enabled Booster Function Overheat gap over Boiler Temperature Threshold Boiler temperature negative differential: when the dishwasher is in standby, boiler threshold becomes: - (Used to save energy during machine inactivity by keeping boiler water at a lower temperature). Tub Temperature: THRESHOLD When tank temperature reaches this value, heater switch off. Tub Temperature: HISTERESIS, (represent dead band). Tank Temperature: HIGH LIMIT. Heater switch on if tank temperature is below: - When tank temperature reaches this value alarm appears. Put 0 to disable alarm. Tank Temperature: LOW LIMIT. During tank warm-up, temperature must increase at least otherwise warning appears. °C Put 0 to disable warning. Tank Filling Timeout. If filling time is longer than , alarm appears. Put 0 to disable alarm. DOC. NO. 5956.65J.00 P. 10 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional To modify thresholds do the following: • Switch OFF and switch ON the dishwasher; • Enter into the FACTORY SETTING mode by pressing and hold down ON/OFF and CYCLE_2 keys for at least five seconds (Figure 33); • Press CYCLE INFINITE. The display shows alternatively the symbol (Figure 34) and the corresponding value (Figure 35); • Use CYCLE_1 key to decrease the value and CYCLE_2 key to increase (Figure 35); • Press CYCLE INFITE key to confirm. The display shows the next parameter (Figure 36) and the corresponding value (Figure 37); • In the same way is possible to change the other parameters; when finished switch OFF and switch ON. FAC Fig. 33 Factory setting mode. 2 Fig. 37 Change value & Store bt° C Fig. 34 Boiler temp. threshold bHi Fig. 38 Tank temp. High limit. 76 Fig. 35 Change value & Store 96 btH Fig. 36 Boiler Temp Hysteresis bLo Fig. 39 Change value & Store. At the end the display will show again and by pressing CYCLE_2 key (Fig. 41) is possible to change cycle duration (see paragraph 7 CYCLE SETTING). ). FAC Fig. 40 Factory setting mode DOC. NO. 5956.65J.00 FAC Fig. 41 Next Family Cy1 Fig. 42 Cycle 1 Family: ENTER. P. 11 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 7 CYCLE SETTING IIn this paragraph is explained how to change cycle phases duration (see paragraph 7.1 CYCLE DIAGRAM). • Switch on the dishwasher; • Enter into the FACTORY SETTING mode: press and hold down ON/OFF and CYCLE_2 keys for at least 5 seconds (Figure 43); • Press CYCLE_2 key to select CYCLE_1 parameters. • Press CYCLE_INFINITE. The display shows alternatively the symbol (Figure 46) and the corresponding value (Figure 47); • Use CYCLE_1 key to increase the value and CYCLE_2 key to decrease (Figure 47); • Press CYCLE_INFINITE key to confirm. The display shows the next parameter (Figure 48) and the corresponding value (Figure 49); • In the same way is possible to change the other parameters;. FAC Fig. 43 Factory setting mode. 0 Fig. 47 Change value & Store FAC Fig. 44 Select next class. 5h1 Fig. 48 Wash duration [sec]. Cy1 Fig. 45 Cycle 1 Family: ENTER. Ln1 Fig. 46 Wash duration [min]. 35 Fig. 49 Wash duration [min].. After settled all parameters referring Cycle 1, by pressing CYCLE_2 key is possible to change the Cycle 2 parameters (Figure 50), (Figure 51) and so on. Cy1 Fig. 50 Cycle 1 Parameters. Cy2 Fig. 51 Cycle 2 Parameters: ENTER. Cy2 Fig. 53 Cycle 2 Parameters: next Family DOC. NO. 5956.65J.00 Ln2 … Fig. 52 Wash duration [min]. Cy3 Fig. 54 Cycle 3 Parameters: ENTER Ln3 … Fig. 55 Wash duration [min]. P. 12 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 7.1 CYCLE DIAGRAM CYCLE TYME IPA Ln Sh PA Pr ri cr dr rPA FP dEt rAi LEGENDA: = wash = pre rinse = rrinse = cold rinse DOC. NO. 5956.65J.00 = drain = rinse pause = final pause = detergent = rinse aid P. 13 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 7.2 Cycle 1 Parameters Sym. Parameter Description Unit Min Max Factory Default Wash Phase Long [min] 0 20 0 Wash Phase Short [s] 1 60 35 Pause [s] 0 20 4 Pre-rinse Duration [s] 0 30 0 Rinse Phase Duration [s] 10 45 16 Cold Rinse Phase Duration [s] 0 50 0 Drain [s] 0 40 16 Final Pause at End of Cycle [s] 0 60 0 Long wash time in mode Thermal Label [min] 0 60 0 Short wash time in mode Thermal Label [s] 0 60 59 Parameter Description Unit Min Max Factory Default Wash Phase Long [min] 0 20 0 Wash Phase Short [s] 1 60 45 Pause [s] 0 20 4 Pre-rinse Duration [s] 0 30 0 Rinse Phase Duration [s] 10 45 16 Cold Rinse Phase Duration [s] 0 50 0 Drain [s] 0 40 16 Final Pause at End of Cycle [s] 0 60 0 Long wash time in mode Thermal Label [min] 0 60 1 Short wash time in mode Thermal Label [s] 0 60 12 Parameter Description Unit Min Max Factory Default Wash Phase Long [min] 0 20 1 Wash Phase Short [s] 1 60 40 Pause [s] 0 20 4 Pre-rinse Duration [s] 0 30 0 Rinse Phase Duration [s] 10 45 16 Cold Rinse Phase Duration [s] 0 50 0 Drain [s] 0 40 16 Final Pause at End of Cycle [s] 0 60 0 Long wash time in mode Thermal Label [min] 0 60 2 Short wash time in mode Thermal Label [s] 0 60 12 [°C] 0 95 0 7.3 Cycle 2 Parameters Sym. 7.4 Cycle 3 Parameters Sym. Boiler Temperature Threshold: only for Cycle 3. This parameter allows having a different rinsing temperature for the third cycle. Only values above 45°C are allowed. DOC. NO. 5956.65J.00 P. 14 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 7.5 Drain/Cleaning Cycle Parameters Sym. Unit Min Max Factory Default Initial Drain Phase Duration [s] 0 240 40 Final Drain Phase Duration [s] 0 240 60 Drain without cleaning cycle - 0 1 0 [wash cycles] 0 200 0 Parameter Description Number of wash cycles possible between one drain cycle and the next 8 OTHER PARAMETERS 8.1 Dishwashing Parameters Sym. Parameter Description Min Initial Pause before start washing (for ALL cycles) [s] 0 10 0 Delay for the 2nd wash pump (PW only) [s] 0 10 3 Active a drain phase at the end of washing phase. [s] 0 40 0 Duration of pause after rinse cycle (valid for dishwashers with door/hood lock device) [See par. 9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE]. [s] 0 60 0 Celsius/Fahrenheit selection 0 = Celsius 1 = Fahrenheit - 0 1 0 Rinse Temperature Display. Enable rinse temperature probe (if installed). 0 = during rinse phase the display shows boiler temperature; 1 = during rinse phase the display shows rinse temperature; - 0 1 0 [p/l] 0 255 0 - 0 5 5 - 0 1 0 Pulse Per Litre. This parameter must be settled in according to flow meter installed [present up to software version 3.12]. Number of wash cycles performable without detergent (only for dishwashers with external detergent level sensor – par. 9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION) [] Max Factory Default Unit Enable mode Thermal Label: if set to 1 it enables the mode and disables the "endless cycle" button Boiler temperature in mode Thermal Label. [°C] 45 97 86 Tank temperature in mode Thermal Label. [°C] 40 90 75 Tank temperature hysteresis in mode Thermal Label. [°C] 0 30 2 Pressure sensor threshold 1 [present up to software version 2.11]. - 0 255 140 Pressure sensor histeresis 1 [present up to software version 2.11]. - 0 255 50 Pressure sensor threshold 2 [present up to software version 2.11]. - 0 255 140 Pressure sensor histeresis 2 [present up to software version 2.11]. - 0 255 50 Note: ,, , parameters emulates a two levels pressure switch, keep in mind that value doesn’t correspond to a physical quantity. DOC. NO. 5956.65J.00 P. 15 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 8.2 Read Only Parameters Parameter Description Main Board Firmware Release - - - - Water softener board software version. (only for dishwashers with incorporated continuous water softener). - - - - Active column: indicates through which of the two continuous water softener columns boiler filling is being carried out: 0 = column A and 1 = column B (only for dishwashers with incorporated continuous water softener). - - - - After maintenance, to clear message, insert 0. - - - - When alarm appears, the machine is frozen and this parameter is 3. After maintenance (see alarm codes document), insert 0 to enable the machine. - - - - This alarm appears in case of malfunctioning in the continuous water softener. To facilitate fault-finding, see par. 13.3 ALARMS THAT DON’T STOP THE DISHWASHER FOR MODELS WITH INCORPORATED CONTINUOUS WATER SOFTENER. - - - - When message appears, the parameter value becomes 3. Unit Min Max Factory Default Sym. 8.3 Communication and HACCP Parameters Parameter Description Serial Device 0 = 8N1 1 = PC connection (DAAS 8E1) 7 = HACCP network (ECAP 8E1+LK485) (LK485 board is necessary) 9 = Dishwashers with incorporated continuous water softener 11 = Machines with incorporated continuous water softener that communicate with LK485 board 16 = HACCP printer (8N1) 32 = MODEM GSM (DAAS 8N1) 33 = MODEM GSM (DAAS 8E1) 48 = Hyper Terminal (8N1) - 0 63 1 Address. This parameter specifies the address of the appliance into the ‘HACCP_network’. Works only if ‘HACCP network’ is selected (see above parameter). - 0 255 1 Print parameter table. - 0 1 1 [°C] 45 95 90 [°C] 0 20 10 [°C] 35 75 68 [°C] 0 20 10 HACCP ‘Basic’ (printer) Boiler temperature: high limit. HACCP ‘Basic’ (printer) Boiler temperature: gap below high limit. HACCP ‘Basic’ (printer) Tank temperature: high limit. HACCP ‘Basic’ (printer) Tank temperature: gap below high limit. DOC. NO. 5956.65J.00 Unit Min Max Factory Default Sym. P. 16 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 8.4 Configuration Parameters Sym. Parameter Description Dishwasher Model: 0 = HOOD TYPE & UNDERCOUNTER 1 = POT WASHER 2 = AUTOMATIC POT WASHER 3 = MEDICAL LINE DISHWASHER WITH LOCK DOOR/HOOD DEVICE Boiler type: 0 = ATMOSPHERIC BOILER 1 = PRESSURE BOILER Unit Min Max Factory Default - 0 3 0 - 0 2 0 0 3 1 - 0 3 - - 0 3 0 - 0 1 1 [°C] 0 85 75 - 0 1 0 - 0 27 9 2 = EXTERNAL BOILER Door type: 0 = AUTOMATIC HOOD 1 = MANUAL HOOD 2 = FRONT LOADING 3 = POT WASHER Default model (see Default tables): 1 = HOOD TYPE 2 = POT WASHER 3 = UNDERCOUNTER Solid State Relay (TRIAC). 0 = not enabled; 1 = SOFT START enabled; 3 = SLOW SOFT START enabled (works only on boards with Solid State Relay). Boiler/Tank heating swap: 0 = boiler heaters and tank heater can work simultaneously; 1 = swap enabled: tank heating starts only boiler temperature is reached; (Note: disabling this function changes the global electrical power of appliance; before enabling this function check available power, supply cable section, fuses in according to User Manual). Tank Filling Mode Enable filling tank by means of rinsing cycles. Ex: = 75 means that boiler water is heated at 75°C, then follows a rinse phase and so on until tank is full. If = 0 the tank is filled by solenoid valve in the traditional way (On machines with incorporated continuous water softener, even if is set to 0, filling occurs through subsequent rinses). Detergent Level Switches 0 = level switches not enabled; 1 = enable detergent level switches; USER INTERFACE MODEL 8 = ACTIVE function disabled (up to version 3.11 [up to serial nr. 42100099] set to 0) 9 = hood type, under counter (up to version 3.11 [up to serial nr. 42100099] set to 1) 13 = LS5 with atmospheric boiler(up to version 3.11 [up to serial nr. 42100099] set to 5) 15 = LS5 with pressure boiler (user interface without display); (up to version 3.11 [up to serial nr. 42100099] set to 7) 24 = LS5 with atmospheric boiler (From Ser. Nr.: 821). See parameter (family installed in the board. DOC. NO. 5956.65J.00 ) to check the software version P. 17 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Sym. Parameter Description Unit Enable “regeneration cycle” key (only for dishwashers with noncontinuous water softener) [See paragraph 9.1 RESIN REGENERATION CYCLE]. Min Max Factory Default - 0 1 0 - 0 1 1 ALARMS ENABLE 0 = alarms disabled (to disable also warnings see and ); 1 = alarms enabled; If this function is disabled, faults can be detected so display do not shows any alarm code. Air gap with float level sensor normally closed (the level sensor is closed when the boiler is empty). E.g. the boiler level sensor for machines with incorporated continuous water softener. - 0 1 0 Forced start of a resin regeneration cycle (only for dishwashers with incorporated continuous water softener). [See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER]. - 0 2 0 Max. rinse water hardness (only for dishwashers with incorporated continuous water softener). After modifying, disconnect and reconnect the machine's main power supply by means of the main switch. [See paragraph 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER]. °fH 4 14 10 Boiler heating control. Defines the max. permissible temperature difference during boiler heating in a time interval of 2 minutes and 30 seconds. °C 25 80 50 Min Max 0.1 s 0.0 s. 20.0 s 15 0.1 s 0.0 s 20.0 s 200 0.1 s 0.0 s. 20.0 s 15 8.5 Parameters for automatic hood type dishwashers Sym. Parameter Description DELAY_K1 Time (during hood lifting) within which S3” must return to the rest position. Unit Factory Default HOOD_TOUT TIMEOUT – max. time allowed for complete hood opening/closing. DELAY_K1_S3 During hood lowering, firstly S3” must cut in and then after a time DELAY_K Time within which K and K’ must be both closed or both open. 0.1 s 0.0 s. 20.0 s 10 DELAY_S3 Time during hood lifting within which the bottom limit switch must return to the rest position.. 0.1 s 0.0 s. 20.0 s 20 DELAY_S5 Time during hood lowering within which the top limit switch must return to the rest position. 0.1 s 0.0 s. 20.0 s 20 Displays the last alarm code relative to automatic hood type dishwashers. - - - 0 Parameter only valid for hood type models. Hood lifting motor absorption threshold. (50 units correspond to a current of approx. 1 ampere). - 0 250 100 .the bottom limit switch S3. DOC. NO. 5956.65J.00 P. 18 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 9 SPECIAL FEATURES 9.1 RESIN REGENERATION CYCLE TANK BOILER The regeneration cycle is activated by pressing the button shown in the figure, for at least 5 seconds. For this key to be enabled parameter (in family ) must be set to 1. At this point you can enter the number of wash cycles that can be performed after each regeneration: parameter in the counters family . If is set to zero the counter is disabled, otherwise after the preset number of cycles the message is displayed to confirm that regeneration is possible (this is an information-only message with no effect on operation of the appliance, so you can continue to use the dishwasher). The message is cleared when the regeneration cycle is terminated. The number of regeneration cycles performed can be checked by consulting the parameter in the family of counters. When there are just 15 cycles remaining before the next regeneration cycle, at the end of the wash cycle the display shows the message followed by , at the end of the next wash cycle the display shows and , and so forth, i.e. the display informs the user of the number of wash cycles still available before resin regeneration is required. Before starting the regeneration cycle remove the siphon spillway. WARNING: If the regeneration cycle is accidentally started, it can be switched off by pressing the button shown in the figure, for at least 5 seconds The hardness of the water exiting the softener can vary between 3°fH - 10 °fH / 1.7 °dH - 5.6 °dH / 2.1 °cH - 7 °cH. 9.2 MEDICAL LINE DISHWASHER WITH DOOR/HOOD LOCK DEVICE The medical line dishwasher with door/hood lock device has a device that prevents door/hood opening for the entire duration of the work cycle. For the door/hood lock to be active, the parameter (in the family) must be set to . The dishwasher door/hood is locked at the start of a wash cycle and is released at the end of the final pause after rinse. The wash compartment can be accessed by stopping the work cycle in progress, as the locking device is thus disabled. . A pause at the end of rinse can be set by means of the parameter (in the family). This parameter is common to all 3 wash cycles. The rinse water temperature is displayed during this pause. Another final pause in the cycle can be set by setting the parameters , , . During the final pause the display shows the time remaining for completion of the cycle. The door/hood lock device will be deactivated at the end of the final pause (, , ). For correct performance of the wash cycle the pause at the end of rinse and the final pause must assume the default values (see Prog 032 – 034 - 035). 9.3 DETERGENT AND RINSE AID LEVEL SENSORS ACTIVATION By setting the parameter (in the family) to 1, management of the level sensors located inside the external detergent and rinse aid tanks is enabled. During the rinse phase, when the rinse aid inside the tank has finished, the message appears on the display. DOC. NO. 5956.65J.00 P. 19 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional When the detergent inside the tank is finished, the message is displayed and after a number of wash cycles equal to (in the family) the dishwasher inhibits the activation of other wash cycles. Therefore the detergent level in the tank must be restored. 9.4 DISHWASHER WITH INCORPORATED CONTINUOUS WATER SOFTENER Dishwashers with incorporated continuous water softener have a continuous softener in the water circuit. By means of special resins, this device removes the calcareous substances from the feed water, supplying decalcified water for washing. To activate the continuous water softener, set the parameter (in the family) to the value or the value if the water softener board is connected to the LK485 board. For the continuous softener to work properly the resins must be regenerated periodically with a frequency depending on the hardness of the inlet water, the number of wash cycles carried out and the max. hardness set with the parameter (in the family). Unlike conventional water softeners, this continuous softener does not require machine stops for regenerating the resins. To regenerate the resins it is necessary to put coarse salt in the special container located in the dishwasher. In particular, the salt container must be filled when the dishwasher is started the first time and whenever the message appears on the display during or at the end of a wash cycle and an audible alarm sounds. The salt container holds up to 1.5 kg of salt WARNING: Use only coarse salt with a NaCl purity grade of 99.8 %. The use of salt with a lower purity grade may cause the sale container filter to clog and the water softener to malfunction. WARNING: The message may appear for several wash cycles even after topping-up the salt, as the salt must circulate in the entire system. Correct operation of the dishwasher is not, however, affected. The number of regeneration cycles performed can be checked by consulting the parameter in the family of counters. only counts regeneration cycles carried out with the salt container adequately filled; there is another counter, (in the family) that indicates the number of regeneration cycles done without salt. If the parameter SrU is set to the value10, according to the factory setting, the water softener outlet water hardness can vary between 3°fH - 10 °fH/ 1.7 °dH - 5.6 °dH / 2.1 °cH - 7 ° cH. AUTONOMY OF A COLUMN OF RESINS ACCORDING TO THE CHANGE IN INLET WATER HARDNESS, WITH OUTLET WATER HARDNESS OF 10 °fH / 5.6 °dH /7 °cH ( according to the factory setting). °fH 15 20 25 30 35 40 °dH 8,4 11,2 14 16,8 19,6 22,4 °cH 10,5 14 17,5 21,1 24,6 28,1 Number of cycles 14 10 7 6 5 4 Maximum outlet water hardness can be modified by setting the value. The outlet water hardness can be modified from the value of 4° fH to 14° fH. NB: To save the new water hardness value, in addition to the normal parameter modification and saving operations it is necessary to disconnect and reconnect the machine's main power supply by means of the main switch on the external board. DOC. NO. 5956.65J.00 P. 20 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Water softener operation can be checked by forcing the regeneration of resins, without waiting for the outlet water hardness to reach the set max. value ( ). To do this, wait for the water softener to finish previous resin washing or regeneration operations and set the parameter ( family) to for regenerating column A or to for regenerating column B. Switch the machine off and on again so that it carries out complete regeneration of the set column. If previous resin washing or regeneration operations were not completed, the manual request for regeneration is not carried out. It is possible to check which column is being used for boiler filling by querying the parameter ( family): if = 0 column “A” is used, if =1 column “B” is used. The number of litres used by the machine can be checked by querying the parameters (m3 ) and (litres). To calculate the total number of litres used by the machine, add the and values. NB: In machines with incorporated continuous water softener, tank filling cannot be carried out through overflowing () but only by means of successive rinse cycles (). Therefore the parameter must be set to 9.5 HOOD-TYPE DISHWASHER WITH CYCLE THERMAL LABEL WARNING: Functions present with firmware version 4.04. If the parameter (Thermal Label enabled) of the family is set to , the "Endless cycle" button has the "endless cycle" function and the "high productivity" mode is non-settable. If the parameter (Thermal Label enabled) of the family is set to , the "Endless cycle" button does not have the "endless cycle" function but that of the "high productivity" mode. This means that the machine can work in 2 modes, "high productivity" and "Thermal Label". When the machine is set in "high productivity" mode, the parameters which define the cycle times and temperature set points are the standard parameters, whereas when the machine is set in "Thermal Label" mode, the parameters are dedicated (they are new parameters listed below). The mode Thermal Label provides for cycle times, tank hysteresis and tank and boiler temperatures such as to pass the "Thermal Label" test. Press and hold down the button to switch the machine from "high productivity" mode to "Thermal Label" mode and vice versa. The "high productivity" button LED is off when the machine is set in "Thermal Label" mode (factory default) and lights up when the button is pressed and the machine is configured in "high productivity" mode. Whenever the machine is shut down, it memorises the mode with which is was switched off and reloads it when switched on the next time. New parameters: • (family ): if set to it enables the Thermal Label mode (and disables the “endless cycle” button). • (family ): temperature set point for the boiler during the cycles Thermal Label. • (family ): temperature set point for the tank during the cycles Thermal Label. • (family ): hysteresis temperature for the tank during the cycles Thermal Label. • (family ): long wash time for cycle 1 in Thermal Label mode. • (family ): short wash time for cycle 1 in Thermal Label mode. • (family ): long wash time for cycle 2 in Thermal Label mode. • (family ): short wash time for cycle 2 in Thermal Label mode. • (family ): long wash time for cycle 3 in Thermal Label mode. • (family ): short wash time for cycle 3 in Thermal Label mode. 9.6 DISHWASHERS WITH WASH TANK WATER CHANGE FREQUENCY CONTROL DOC. NO. 5956.65J.00 P. 21 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional WARNING: Function included starting from firmware version 5.00. If the parameter (Cycles before drain) of the family is set to a value higher than , a wash tank water change frequency control is enabled. The purpose of this function is to display a message telling the customer when a tank water drain cycle is required. In this way, if the customer does what the machine suggests, washes will be done with sufficiently clean water. The value set in the parameter (Cycles before drain) indicates the number of wash cycles possible between one tank water drain cycle and the next. When the number of wash cycles done since the last tank water change reaches the value contained in the parameter (Cycles before drain), the display shows the message “” at the start of a wash cycle and the message “” at the end of the same cycle. When these messages appear on the display at the start and end of the wash cycle, a tank water drain cycle must be done to ensure washes with sufficiently clean water. WARNING: If the tank drain cycle is not done, the machine does not shut down, but will continue to do wash cycles, showing the messages and at the start and end of the wash cycle respectively. DOC. NO. 5956.65J.00 P. 22 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 10 MAIN BOARD CONFIGURATION When receiving an electronic board (spare part) may be necessary to configure it in according to the machine where has to be replaced 1. With the machine CODE enter into the following table and read the corresponding Prog. number 2. Follow the instructions reported into the corresponding Prog.XXX sheet (next pages). 3. With the machine CODE find the Layout number in Par. 12.2 CONNECTORS LAYOUT. 10.1 CODE -> Prog. TABLE MODEL NUC3DD CODE 400041 Prog. 103 Layout MODEL CODE Prog. Layout 16 EUCIM 502044 115 19 502045 115 19 EUC1 400055 101 11 EUCIM60 EUC1DP 400056 101 11 EUCAIDPNW 502046 106 8 EUC1WS 400057 102 21 ZUCI 502047 114 16 EUC1DPWS 400058 102 21 ZUCID 502048 114 16 16 ZUCAI 502049 106 8 502050 106 8 EUC3 400059 103 EUC3WS 400060 104 17 ZUCAIDP EUC3DP 400061 103 16 ZUCAIDPWS 502051 107 8 EUC3DPWS 400062 104 17 ZUCAIG 502052 106 8 EUC1G 400063 105 11 ZUCAIDDWS 502053 107 8 11 ZUCAID 502054 106 8 16 ZUCAI60 502055 106 8 EUC1DP60 EUC3DD 400064 400065 101 103 ZUCADDROW 400066 134 16 EUCAIUSPH6 502056 125 9 ZUCADDROW6 400067 134 16 ZUCAIDD 502057 106 8 FUCA3DD 400116 135 16 EUCAIDD 502058 106 8 16 EUCAIDPJ 502059 106 8 16 EUCAIDPJ60 502060 106 8 KUC3 KUC3DP 400127 400128 103 103 NUC1 400140 101 11 EHTA 504226 120 1 NUC1DP 400141 101 11 EHTA60 504227 120 1 NUC1WS 400142 102 21 EHTAWS 504228 121 4 21 EHTAI 504229 120 1 16 EHTAID 504230 120 4 504231 121 4 NUC1WSDP NUC3 400143 400144 102 103 NUC3WS 400145 104 17 EHTAIWS NUC3DP 400146 103 16 EHTAIDWS 504232 121 4 NUC3DPWS 400147 104 17 EHTAIG 504233 120 4 17 EHTAIWSG 504234 121 4 504235 122 15 NUC3DDWS 400148 104 NUC1DP60 400149 101 11 EHTAIAU NUC1DPA 400150 105 11 EHTAIMLAU 504236 123 4 ZUCA1 400151 128 11 ZHTAWS 504237 121 4 ZUCA3 400152 128 16 ZHTAID 504238 120 4 EUCADDROW 400153 134 16 ZHTAIWS 504239 121 4 504240 122 15 EUCADDROW6 400154 134 16 ZHTAIAU EUCAI 502025 106 8 ZHTA 504241 120 4 EUCAIDP 502026 106 8 ZHTA60 504242 120 4 EUCAI60 502027 106 8 ZHTAI 504243 120 4 EUCAIWS 502028 107 8 EHTAIUSPH5 504244 126 2 8 EHTAIUSPH6 504245 126 2 505036 124 23 EUCAIG 502033 106 EUCAIWSG 502034 107 8 EHTAO EUCAIML 502035 108 8 EHT 505046 118 13 EUCAIMLWS 502036 109 8 EHT60 505047 118 13 EUCAIMLG 502037 110 10 EHTAG 505048 119 23 18 EHTM 505049 118 13 18 EHTM60 505050 118 13 505051 118 13 EUCAICL EUCAICLG 502038 502039 111 111 EUCAIWL 502040 112 8 NHT EUCAICLW 502042 113 18 NHTD 505052 118 13 EUCI 502043 114 16 NHT60 505053 118 13 EHTAROW 505054 124 23 DOC. NO. 5956.65J.00 P. 23 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional MODEL CODE Prog. Layout EHTAROW60 505055 124 23 ZHTAROW 505056 124 23 ZHTAROW60 505057 124 23 EHTAJ 505058 120 23 EHTAJ60 505059 120 23 EHTAO60 505060 124 23 ZHTAO 505061 124 23 ZHTAO60 505062 124 23 KHT 505063 118 13 NHTM 505064 118 13 NHTM60 505065 118 13 EPPWESG 506048 139 4 EPPWESG60 506049 139 4 EPPWEHG 506050 139 4 ZPPWESG 506051 139 4 ZPPWEHG 506052 139 4 ZPPWSSG 506053 139 4 EPPWELG 506054 140 4 EPPWELG60 506055 140 4 ZPPWELG 506056 140 4 ZPPWSLG 506057 140 4 NUC1G 690028 105 11 NUCA1DDG 698005 136 16 OHTAROW 698047 127 23 OHTAROW60 698048 127 23 APPWELG 698083 140 4 APPWESG 698085 139 4 APPWEHG 698086 139 4 ET5AIIT 698087 131 8 ET5AIDP 698088 132 8 ET5AIDPWS 698089 133 8 AUCI 698091 114 16 AUCAI 698092 116 8 AUCAIDP 698093 116 8 AUCAIDPWS 698094 117 8 AUCAIG 698095 106 8 AUCAIWSG 698096 107 8 ET12AI 698097 129 4 ET12AIT 698098 130 4 NHTAG 698110 119 23 AHTAWS 698115 121 4 AHTAIWS 698116 121 4 AHTAIG 698117 120 4 AHTAIWSG 698118 121 4 AHTA 698119 120 4 AHTAI 698120 120 4 S49JGF 103 16 S49LBN 103 16 S49QL1 103 16 DOC. NO. 5956.65J.00 P. 24 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 10.2 PROGRAMMING SHEETS NUC1 / EUC1 PROG 101 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 25 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1 / EUC1 PROG 101 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when LOAD SOLENOID VALVE in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 26 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1WS / EUC1WS PROG 102 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle enabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 27 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1WS / EUC1WS PROG 102 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 28 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC3 / KUC3 / EUC3 PROG 103 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 29 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC3 / KUC3 / EUC3 PROG 103 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when LOAD SOLENOID VALVE in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 30 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC3WS / EUC3WS PROG 104 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle enabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 31 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC3WS / EUC3WS PROG 104 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 32 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1G / EUC1G PROG 105 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 33 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1G / EUC1G PROG 105 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when LOAD SOLENOID VALVE in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 34 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCAI / AUCAIG / EUCAI PROG 106 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled. Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 35 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCAI / AUCAIG / EUCAI PROG 106 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode disabled (Functions present with firmware version 4.04). Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 36 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCAI / AUCAI / EUCAI WS PROG 107 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler float level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 37 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCAI / AUCAI / EUCAI WS PROG 107 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Dishwasher with incorporated continuous water softener. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 38 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIML PROG 108 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 39 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIML PROG 108 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 40 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIMLWS PROG 109 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler float level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 41 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIMLWS PROG 109 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Dishwasher with incorporated continuous water softener. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 42 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIMLG PROG 110 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Medical line dishwasher with lock door/hood device. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 43 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIMLG PROG 110 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Delay for the 2nd wash pump [s]. Drain Phase Duration at the end of washing phase [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 44 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAICL PROG 111 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 45 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAICL PROG 111 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 46 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIWL PROG 112 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 47 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIWL PROG 112 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 48 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAICLW PROG 113 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 49 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAICLW PROG 113 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 50 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCI / AUCI / EUCI PROG 114 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 51 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCI / AUCI / EUCI PROG 114 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 52 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCIM PROG 115 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 53 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCIM PROG 115 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 54 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional AUCAI PROG 116 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 55 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional AUCAI PROG 116 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 56 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional AUCAIDPWS PROG 117 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler float level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 57 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional AUCAIDPWS PROG 117 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Dishwasher with incorporated continuous water softener. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 58 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NHT / KHT / EHT PROG 118 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible).. Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 59 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NHT / KHT / EHT PROG 118 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 60 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NHTG / EHTG PROG 119 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 61 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NHTG / EHTG PROG 119 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 62 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTA / AHTA / EHTA PROG 120 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 63 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTA / AHTA / EHTA PROG 120 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode disabled (Functions present with firmware version 4.04). Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 64 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTAWS/ AHTAWS/ EHTAWS PROG 121 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler float level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 65 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTAWS/ AHTAWS/ EHTAWS PROG 121 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Dishwasher with incorporated continuous water softener. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 66 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTAIAU / EHTAIAU PROG 122 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Automatic Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 67 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTAIAU / EHTAIAU PROG 122 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 68 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EHTAIMLAU PROG 123 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Automatic Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 69 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EHTAIMLAU PROG 123 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 70 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTAROW / EHTAROW / ZHTAO / EHTAO PROG 124 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Boiler heaters and tank heater work simultaneously. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tank Temperature: Threshold. Disable tank high Temperature alarm ( ). 5. Modify the cycle parameters: Cycle 1 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase inTermal Label mode [min]. Short Wash Phase inTermal Label mode [s]. Cycle 2 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase inTermal Label mode [min]. Short Wash Phase inTermal Label mode [s]. P. 71 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZHTAROW / EHTAROW / ZHTAO / EHTAO Cycle 3 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase inTermal Label mode [min]. Short Wash Phase inTermal Label mode [s]. Boiler Temperature Threshold for Cycle 3. Drain parameters family. PROG 124 Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Delay for the 2nd wash pump [s]. Drain Phase Duration at the end of washing phase [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode enabled. Boiler Temperature in Termal Label mode. Tank Temperature in Termal Label mode. Tank Temperature histeresis in Termal Label mode. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 72 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIUSPH PROG 125 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 73 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EUCAIUSPH PROG 125 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees display Fahrenheit. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 74 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EHTAIUSPH PROG 126 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 75 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional EHTAIUSPH PROG 126 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees display Fahrenheit. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 76 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional OHTAROW / OHTAROW60 PROG 127 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. Disabled (for this appliance SOFT START is NOT possible). Boiler heaters and tank heater work simultaneously. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Disable boiler high Temperature alarm ( ). Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tank Temperature: Threshold. Disable tank high Temperature alarm ( ). 5. Modify the cycle parameters: Cycle 1 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase inTermal Label mode [min]. Short Wash Phase inTermal Label mode [s]. Cycle 2 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase inTermal Label mode [min]. Short Wash Phase inTermal Label mode [s]. P. 77 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional OHTAROW / OHTAROW60 Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. Long Wash Phase inTermal Label mode [min]. Short Wash Phase inTermal Label mode [s]. Drain parameters family. PROG 127 Cycle 3 parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Delay for the 2nd wash pump [s]. Drain Phase Duration at the end of washing phase [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode enabled. Boiler Temperature in Termal Label mode. Tank Temperature in Termal Label mode. Tank Temperature histeresis in Termal Label mode. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when WASH PUMP in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 78 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCA PROG 128 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 79 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCA PROG 128 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 80 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET12AI PROG 129 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. SOFT START enabled. Boiler heaters and tank heater work simultaneously. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 81 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET12AI PROG 129 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode disabled (Functions present with firmware version 4.04). Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when WASH PUMP in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 82 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET12AIT PROG 130 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Manual Hood. Default values for Hood Type models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 83 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET12AIT PROG 130 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode disabled (Functions present with firmware version 4.04). Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when WASH PUMP in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 84 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET5AIIT PROG 131 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Boiler heaters and tank heater work simultaneously. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled. Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 85 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET5AIIT PROG 131 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when WASH PUMP in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 86 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET5AIDP PROG 132 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Boiler heaters and tank heater work simultaneously. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled. Alarms enabled. Boiler float level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 87 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET5AIDP PROG 132 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Dishwasher with incorporated continuous water softener. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when WASH PUMP in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 88 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET5AIDPWS PROG 133 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. ACTIVE function disabled. Regeneration cycle disabled. Alarms enabled. Boiler float level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 89 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ET5AIDPWS PROG 133 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Dishwasher with incorporated continuous water softener. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when WASH PUMP in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 90 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCADDROW / EUCADDROW PROG 134 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tub Temperature: HISTERESIS. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 91 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZUCADDROW / EUCADDROW PROG 134 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 92 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional FUCA3DD PROG 135 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 93 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional FUCA3DD PROG 135 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 94 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUCA1DDG PROG 136 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Atmospheric boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. Enable filling tank by means of rinsing cycles. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 95 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUCA1DDG PROG 136 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 96 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1GMS PROG 137 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 97 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC1GMS PROG 137 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when LOAD SOLENOID VALVE in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 98 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC3 / KUC3 / EUC3 PROG 138 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Hood Type and undercounter. Pressure boiler. Front loading function. Default values for Undercounter models. SOFT START enabled. Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface for LS5. Regeneration cycle disabled. Alarms not enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 99 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional NUC3 / KUC3 / EUC3 PROG 138 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Number of wash cycles possible between one drain cycle and the next. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispenser works when LOAD SOLENOID VALVE in activated. Rinse Aid dispenser works when LOAD SOLENOID VALVE in activated. 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 100 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZPPW / APPW / EPPW (EX PW1 / PW1H) PROG 139 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Pot Washer. Atmospheric boiler. Front loading function. Default values for Pot Washer models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 101 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZPPW / APPW / EPPW (EX PW1 / PW1H) PROG 139 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode disabled (Functions present with firmware version 4.04). Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 102 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZPPW / APPW / EPPW (EX PW2) PROG 140 1. Switch OFF and then switch ON the machine. 2. Enter into CFG parameter family and set the following parameters: Pot Washer. Atmospheric boiler. Front loading function. Default values for Pot Washer models. Disabled (for this appliance SOFT START is NOT possible). Tank heater works only if boiler temperature reached. The tank is filled into the traditional way. Detergent level switches not enabled. Select user interface hood type/ undercounter model. Regeneration cycle disabled (only for dishwashers with non-continuous water softener). Alarms enabled. Boiler electronic level sensor. Resin regeneration cycle forcing. Rinse water max. hardness. Boiler heating control. 3. Switch OFF and then switch ON the machine. 4. Modify Factory parameters: Enter into FAC parameter family and set the following parameters. Boiler Temperature Threshold. Boiler temperature: alarm threshold. Boiler Temperature Adjust. Boiler standby function enabled. Booster Function. During stand-by boiler is kept at lower temperature than Temperature Threshold. Tub Temperature: Threshold. Tank temperature: alarm threshold. 5. Modify the cycle parameters: Cycle 1 parameters family. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Cycle 3 parameters family. DOC. NO. 5956.65J.00 Long Wash Phase [min]. Cycle 2 parameters family. Long Wash Phase [min]. Short Wash Phase [s]. Pause [s]. Rinse Phase Duration [s]. Drain [s]. Final Pause [s]. Boiler Temperature Threshold for Cycle 3. P. 103 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional ZPPW / APPW / EPPW (EX PW2) PROG 140 Drain parameters family. Initial Drain Phase Duration [s]. Final Drain Phase Duration [s]. Drain and cleaning mode. Wash tank water change frequency control disabled. Set other parameters. Initial Pause [s] (for ALL cycles). Drain Phase Duration at the end of washing phase [s]. Delay for the 2nd wash pump [s]. Duration of pause after the rinse cycle [s] (for ALL cycles). Degrees Celsius display. During the rinse stage, the display shows the boiler temperature. Termal Label mode disabled (Functions present with firmware version 4.04). Enter into HCP parameter family and set the following parameters. Machine arranged for remote connection to PC. 6. Switch OFF and then switch ON the machine. Enter into GEn parameter family. Initial Detergent Dosage. Initial Rinse Aid Dosage. Detergent dispensing during the wash cycle (loading during wash stage). Rinse aid dispensing during the rinse cycle (loading during boiler filling stage). 7. Switch OFF and then switch ON the machine. WARNING: To set the board parameters , carefully follow the order given in this programming file, from point 1 to point 7. WARNING: When modifying parameter , all the parameters (except those belonging to the family) assume the default values according to the tables in section 11 DEFAULT VALUES. The parameters of the family are not modified. DOC. NO. 5956.65J.00 P. 104 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 11 DEFAULT VALUES Default 1 - HOOD TYPE ON/OFF + CYCLE1 keys ON/OFF + CYCLE2 keys DOC. NO. 5956.65J.00 P. 105 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Default 2 - POT WASHER ON/OFF + CYCLE1 keys ON/OFF + CYCLE2 keys DOC. NO. 5956.65J.00 P. 106 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Default 3 - UNDERCOUNTER ON/OFF + CYCLE1 keys ON/OFF + CYCLE2 keys DOC. NO. 5956.65J.00 P. 107 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 12 USER INTERFACE AND MAIN BOARD CONNECTORS 12.1 MAIN MALFUNCTIONS NOT DUE TO THE MAIN BOARD The display shows with door/hood closed No cycle starts A cycle fails to start After replacing the main board only the 3rd cycle starts Cycle time longer than that foreseen Noisy wash pump (only on HT and PP versions) Check door/hood micro/sensor Check the user interface buttons (have they remained pressed? etc.) Is a user interface button extension missing? The main board is still configured for LS5/WT4. Does the boiler work? Is the feed water at 50°C? Check the current for single phase during operation. 12.2 CONNECTORS LAYOUT LAYOUT 1 KEY CN1 CN2 CN3 CN5 CN8 CN12 CN15 CN16 ZHTA / AHTA / EHTA Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection Detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Energy peak controller input User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input DOC. NO. 5956.65J.00 P. 108 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional LAYOUT 4 ZHTA / AHTA / EHTA / ZHTAWS / AHTAWS / EHTAWS ZPPW / APPW / EPPW (NO AUT) ONLY WS LAYOUT 8 NUC / EUC / NUCWS / EUCWS / NUCI / EUCI / NUCIWS / EUCIWS ONLY WS KEY CN1 CN2 CN3 CN5 CN7 CN8 CN10 CN11 CN12 CN15 CN16 Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection ECOTEMP transformer, detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Hand safety system microswitch input Energy peak controller input Safety and upper/lower limit switch input Hand safety system input - Gear motor current control input - Gear motor polarity inversion connection User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input DOC. NO. 5956.65J.00 P. 109 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional KEY CN1 CN2 CN3 CN5 CN8 CN11 CN12 CN15 CN16 CN17 LAYOUT 10 EUCIM / EUCAIMLG LAYOUT 11 NUC1 / EUC1 / ZUCA1 ATM PRES (ZUCA1) (NUC1 / EUC1) Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection Detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Energy peak controller input Door lock electromagnet output User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input Door microswitch connector DOC. NO. 5956.65J.00 P. 110 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional LAYOUT 13 LAYOUT 15 KEY CN1 CN2 CN3 CN5 CN8 CN11 CN12 CN15 CN16 NHT / EHT / KHT ZHTAAU / EHTAAU Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection ECOTEMP transformer, detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Energy peak controller input Hood lock electromagnet output User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input DOC. NO. 5956.65J.00 P. 111 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional LAYOUT 16 NUC / EUC / ZUCI / AUCI /EUCI / ZUCA3 / FUCA3DD / NUCA1DDG / KUC / ZUCADDROW / EUCADDROW ATM PRES (NUC / EUC / (ZUCA3 / ZUCI / AUCI / FUCA3DD / NUCA1DDG / EUCI / KUC) ZUCADDROW / EUCADDROW) LAYOUT 17 KEY CN1 CN2 CN3 CN5 CN8 CN9 CN11 CN12 CN15 CN16 CN17 NUCWS / EUCWS Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection Detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Energy peak controller input Salt receptacle drain pump and low pressure solenoid valve outputs Brine solenoid valve output User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input Door microswitch connection DOC. NO. 5956.65J.00 P. 112 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional LAYOUT 18 LAYOUT 19 KEY CN1 CN2 CN3 CN5 CN7 CN8 CN12 CN15 CN16 CN17 EUCAICL EUCIM / EUCIM60 Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection Detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Detergent/rinse aid level sensors input Energy peak controller input User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input Door microswitch connection DOC. NO. 5956.65J.00 P. 113 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional LAYOUT 21 LAYOUT 23 KEY CN1 CN2 CN3 CN5 CN8 CN9 CN11 CN12 CN15 CN16 CN17 NUC1WS / EUC1WS NHTG / EHTG / ZHTAROW / EHTAROW / ZHTAO / EHTAO Rinse pump/wash pump/solenoid valve outputs Pressure/atmospheric dishwasher solenoid valve connection Detergent/rinse aid dispenser and drain pump outputs Tank/boiler temperature sensor inputs Energy peak controller input Salt receptacle drain pump and low pressure solenoid valve outputs Brine solenoid valve output User interface inputs/outputs Overflow/tank level/board feed input User interface inputs/outputs and hood/door sensor input Door microswitch connection DOC. NO. 5956.65J.00 P. 114 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 13 ALARM MESSAGES AND TROUBLESHOOTING 13.1 ALARMS THAT STOP THE DISHWASHER Want of water Is the water cock open? Does the water load solenoid valve work? Is the water feed flow a min. of 5 l/min? Is the water inlet filter clean? Is the load solenoid valve filter clean? Is the overflow inserted? Is the main board (ATM-PRES) CN2 connector correctly positioned? Do the tank/boiler pressure switches work properly? Rinsing is not done regularly for 2 consecutive cycles Are the rinse arms clogged? Does the rinse pump work correctly? Is there water in the level sensor tube? Is there scale in the boiler? Does the boiler level sensor work properly? ONLY FOR MACHINES WITH CONTINUOUS WATER SOFTENER: Does the boiler level sensor located inside the water softener work properly? Does the float of the boiler level sensor, located inside the water softener, work properly? Is it free to move upwards and downwards and vice versa? Is the connection from the boiler level sensor to the main board efficient? ATTENZIONE: RESETTING THIS ALARM WITHOUT FIRST ELIMINATING THE CAUSE IS DANGEROUS; THE BOILER HEATING ELEMENTS COULD WORK DRY, FURTHER DAMAGING THE INTERNAL PARTS OF THE DISHWASHER. ATTENZIONE: IT MUST BE MANUALLY RESET AFTER ELIMINATING THE CAUSE OF THE MALFUNCTION. Automatic hood out of order See par. 13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS. 13.1.1 ALARM CODES FOR AUTOMATIC HOOD TYPE DISHWASHERS When the alarm appears, to facilitate fault-finding another parameter providing a more detailed indication has been introduced. The parameter is and is found in the family. The possible cause of the anomaly can be found (see table below) ?according to the value of the parameter . With pot washers the cause that generated a type alarm can also be found. E.g.: With an automatic hood type the alarm appears. Access the parameter in the family. the top limit switch could be disconnected or interrupted. DOC. NO. 5956.65J.00 P. 115 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Hood Pot Washer S5' S5 S3: FC_DW (hood CLOSE) S5: FC_UP (hood OPEN) S4'' S4''' S3'' S4' S4 S3 S3' S1: DOOR_CLOSE Appears with hood closed if the top limit switch (FC_UP) cuts in. Appears with hood closed, if: - the bottom limit switch (S3) returns to the rest position; - the top limit switch (S5) cuts in; - S3’’ does not cut in. During lifting, the bottom limit switch (FC_DW) has not returned to the rest position. The limit switch must return to the rest position within a time given by the parameter : a) check that the motor works. otherwise the alarm appears. - S3 could be stuck. - S5’ could be disconnected. On installation this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board Appears if during lifting S3’’ does not return to the rest position within a time . Appears if the bottom limit switch (FC_DW) cuts in during lifting. (Polarity/motor rotation direction inverted?!). During the initial lifting phase the bottom limit switch (S3) must return to the rest position within a time given by the parameter ? Appears if the bottom limit switch (S3) cuts in during lifting. On installation this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. DOC. NO. 5956.65J.00 P. 116 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional TIMEOUT-The time taken for hood lifting was more than the time fixed by parameter : TIMEOUT- IThe time taken for lifting was more than the time fixed by parameter . a) check that the motor works. Check correct operation of the: a) motor (thermal protection N7); b) top limit switch (S5 and S5’). The hood is open but the bottom limit switch (FC_DW) has cut in. Appears with hood fully open, if: - the limit switch (S5) returns to the rest position; - the bottom limit switch (S3) cuts in; - S3’’ cuts in. Appears if with hood fully open the "door closed" microswitch cuts in. Appears if with hood fully open the "door closed" microswitch cuts in. - S5 could be disconnected. During lowering, the top limit switch (FC_UP) has not returned to the rest position. The limit switch must return to the rest position within a time given by parameter : a) check that the motor works; b) (Polarity/motor rotation direction inverted?!).. During the initial lowering phase the top limit switch (S5) must return to the rest position within a time given by the parameter otherwise the alarm appears. - S5 could be stuck. - S3’ could be disconnected. On installation, this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. - Appears if the bottom limit switch S3 cuts in before S3" during lowering. Appears if the top limit switch (FC_UP) cuts in during lowering. (Polarity/motor rotation direction inverted?!). Appears if the top limit switch (S5) cuts in during lowering. On installation, this alarm can occur due to incorrect sequence of the phases: invert the two phases on the power supply terminal board. TIMEOUT- The time taken for hood closing was more than the time fixed by parameter : TIMEOUT- The time taken for lowering was more than the time fixed by parameter . a) check that the motor works. - S3’ could be disconnected. - DOC. NO. 5956.65J.00 Appears during hood lowering if, after S3’’ cuts in, the bottom limit switch S3 does not cut in within the time fixed by parameter . P. 117 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional - The two hand safety contacts K and K' must be both closed or both open. If this does not occur the alarm appears. - One of the two relays (K or K’) could be stuck or disconnected. (See parameter ) Limit switch combination not allowed: top limit switch (FC_UP) and bottom limit switch (FC_DW) activated at the same time! Limit switch combination not allowed. Appears if one of the following combinations occurs: - top limit switch (S5) and bottom limit switch (S3) both activated (S3 and S5 could be disconnected); - top limit switch S5 and S3’’ both cut in; - bottom limit switch (S3) cut in but not S3’’. - During lifting, the current absorbed by the lifting motor has exceeded the threshold (see parameter ): a) excessive mechanical force during lifting.. - During lowering, the current absorbed by the lifting motor has exceeded the threshold (see parameter ): excessive mechanical force during lowering. - DOC. NO. 5956.65J.00 The hood should be stopped but the card detects a high current absorption by the lifting motor: the relay RL18/RL19 could be stuck; feeder connector CN32 could be disconnected. P. 118 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 13.2 ALARMS THAT DON'T STOP THE DISHWASHER (SHOWN ON THE USER INTERFACE AT REGULAR INTERVALS) WARNING: Alarms marked with the Θ symbol from Serial Number 821 have become alarms which do not lock the machine. Drain not efficient Has the overflow been removed? Is the water drain blocked? Is the drain pump blocked? Are the air trap and tank pressure switch clean? Is there a constriction in the drain tube? Is the pump breather pipe returning to the tank clogged or constricted? Does the tank pressure switch work properly? Is there a hole in the drain tube (only for versions with drain pump)? Overflow alarm Is the water drain blocked? Are the air trap and tank pressure switch clean? Does the tank pressure switch work properly? Is the load solenoid valve blocked? (E1 - LOAD_EV) Is the load solenoid valve relay stuck? (RL8 - LOAD_EV) Θ Boiler temperature rise too fast Does the boiler level sensor work properly? The boiler could be empty. Are non-original power resistances installed? Θ Boiler temperature too high Has the boiler temperature been changed ( - increased above 90°C)? Has the software alarm value been modified ()? Does the boiler level sensor work properly? Is the boiler relay stuck (see RL2, RL3, RL4)? Θ Tank temperature too high Is the feed water above 60°C? Has the software alarm value been modified ()? Is the rinse water temperature too high? Is the tank relay stuck (RL5 - TUB_HEAT)? Θ Tank temperature sensor out of order Is the temperature sensor broken or disconnected (NT1)? Is the temperature sensor connector correctly inserted? Θ Tank temperature sensor out of order Is the temperature sensor short-circuited (NT1)? DOC. NO. 5956.65J.00 P. 119 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Θ Boiler temperature sensor out of order Is the temperature sensor broken or disconnected (NT2)? Is the temperature sensor connector correctly inserted? Θ Boiler temperature sensor out of order Is the temperature sensor short-circuited (NT2)? Θ Rinse temperature sensor out of order (only on machines with temperature sensor on the rinse circuit) Is the temperature sensor broken or disconnected? Is the temperature sensor connector correctly inserted? Θ Rinse temperature sensor out of order (only on machines with temperature sensor on the rinse circuit) Is the temperature sensor short-circuited? WARNING: Alarms , and lock the boiler temperature control. Alarms , and lock the tank temperature control. In the case of alarms and , the boiler waiting phase is not executed (the rinse may be performed with cold water) and, during the initial warm-up and subsequent rinses ( > ), the boiler heating phase is not executed. In the case of an open probe error ( , e ), the displayed temperature is 10°C In the case of a shorted probe error ( , e ) , the displayed temperature is 99°C. Communication error Is the connection between main board and control panel correct? Are the connectors correctly connected? Are connector contacts clean? Tank temperature low Does the tank heating element work properly? Are the connectors correctly connected? Are the dishwasher feed voltage and current correct? Is the relay RL5 on the board disconnected or faulty? Boiler temperature low Does/do the boiler heating element/s work properly? Are the connectors correctly connected? Does the possible remote control switch connected to the heating element work correctly? Is there power at the remote control switch input terminals? Does relay RL2 on the board work properly? CAUTION: IF THERE IS A MALFUNCTION ON RELAY RL2 AND THE BOILER HEATING ELEMENTS ARE FED BY MEANS OF A REMOTE CONTROL SWITCH, THE BOARD DOES NOT HAVE TO BE REPLACED; JUST MOVE THE BOILER HEATING ELEMENT CONNECTOR TO ONE OF THE TWO FREE POSITIONS ON THE BOARD. CAUTION: WHEN ONE BRANCH OF THE HEATING ELEMENT DOES NOT WORK AND THE OTHER TWO CONTINUE TO FUNCTION, ON REACHING THE SET TEMPERATURE VALUE, ALARM 3 DISAPPEARS AND REAPPEARS IN THE SUBSEQUENT RINSE PHASE. THIS ALSO OCCURS WHEN A PHASE IS MISSING. DOC. NO. 5956.65J.00 P. 120 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional 13.3 ALARMS THAT DON’T STOP THE DISHWASHER FOR MODELS WITH INCORPORATED CONTINUOUS WATER SOFTENER If alarm or appears, the machine indicates it on the display at regular intervals and auto-configures itself in the same way as a machine without water softener. Resin regeneration cycles are not performed and the column used for filling is always the same (column B). Alarm is reset when the machine is switched off and on from the mains switch (only if the causes that generated it have been eliminated). Alarm is reset when the machine is switched off and on from the user interface or from the main switch (only if the causes that generated it have been eliminated). WARNING: Alarms marked with the Θ symbol from Serial Number 821 have become alarms which do not lock the machine. Θ Water softener operation errors This alarm appears in case of malfunctioning in the continuous water softener. To reset error it is necessary to disconnect and reconnect the main power supply to the machine by means of the main switch on the external power board. Θ Communication errors between the mother board and softener board This alarm appears in case of problems in communication between the mother board and water softener board; check the connection between mother board connector J1 and water softener connector ST8 To facilitate the finding of faults signalled by alarm , another parameter providing a more detailed indication of the family (see table below). possible cause of malfunction has been introduced in the To reset error it is necessary to disconnect and reconnect the main power supply to the machine by means of the main switch on the external power board. Water softener conductivity sensor short-circuit Two or more water softener conductivity sensors are short-circuited. Check the connections between the water softener board and sensors, replacing the connection wiring if necessary. Water softener conductivity sensors open One or more water softener conductivity sensors are disconnected. Check the connections between the water softener board and sensors, replacing the connection wiring if necessary. Resin temperature sensor malfunction Replace the water softener electronic board. DOC. NO. 5956.65J.00 P. 121 / 122 Electrolux EFS - Dishwashing Systems Platform Electrolux Professional Water softener electronic board malfunction Replace the water softener electronic board. Salt water filling malfunction The salt water container in the water softener was not completely filled within the set max. filling time. Make sure: - the water cock is open - the water filling solenoid valve works correctly - the salt container solenoid valve works correctly ( up to - the feed water pressure is at least 50 kPa / 0.5 bar version 4.01) - the water inlet filter is clean - the filling solenoid valve filter is clean - the salt container cap is properly closed - the mother board (ATM-PRES) connector CN2 is correctly positioned - the water softener board connector ST5 is correctly positioned - the grille on the bottom of the salt container is clogged with dirt. Inefficient resin washing After carrying out the maximum permissible number of resin washes, the resins are not sufficiently cleaned by the salt water used to regenerate them. Make sure: - the water filling solenoid valve works correctly - the feed water pressure is at least 50 kPa / 0.5 bar - the water inlet filter is clean - the filling solenoid valve filter is clean - the mother board (ATM-PRES) connector CN2 is correctly positioned. 14 LIST OF PARAMETERS FOR SUBSEQUENT VERSIONS The parameters listed below, even if present inside the software, cannot be used in appliances currently in production. Family : • • parameter value Family Family - alarm • parameter , the maximum value it can be set to is 3, but actually the only significant values are 0 and 1. By setting to 3, alarm F8 may appear, also implemented by the firmware, but not used in any current application. DOC. NO. 5956.65J.00 P. 122 / 122
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Author : ITCTUDAN Create Date : 2011:11:17 09:25:37+01:00 Modify Date : 2011:11:17 09:25:37+01:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Title : 595665J00_EN.fm Creator : ITCTUDAN Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 10.1.1 (Windows) Document ID : uuid:305e9289-efa4-4e88-827b-9dcdcf614ca6 Instance ID : uuid:9d8c64d7-8b5c-431d-98d0-89db7ddbdd39 Page Count : 122EXIF Metadata provided by EXIF.tools