Asphalt Code Approval Guide Firestone Building Products
User Manual:
Open the PDF directly: View PDF .
Page Count: 82
Download | ![]() |
Open PDF In Browser | View PDF |
Asphalt Roofing Systems Code Approval Guide Page 1 June 20, 2018 The assemblies in this document must be verified with the associated Firm’s (UL, FM, etc.). Not all the information included in the RoofNav assemblies will be listed in the charts below. Please verify that all assemblies meet Firestone Building Products warranty requirements with the associated regions technical team. Contents Underwriters Laboratories (UL) External Fire Ratings .................................................................................. 5 Maintenance and Repair Systems................................................................................................................. 5 General Notations ......................................................................................................................................... 6 General System Variations – V‐Force, Alternate Products or Application.................................................... 7 Asphalt Systems with Surfacing – Class A ..................................................................................................... 8 Asphalt Systems with Surfacing – Class B ................................................................................................... 11 Asphalt Systems with Surfacing – Class C ................................................................................................... 12 Combination Hot & Cold Systems – Class A ................................................................................................ 12 Combination Hot & Cold Systems – Class B ................................................................................................ 16 Any UL Classified Modified Bitumen Systems – Class A, B or C .................................................................. 16 Ballasted Systems – Class A ........................................................................................................................ 17 Fully Adhered Systems – Class A ................................................................................................................. 18 Fully Adhered Systems – Class B ................................................................................................................. 31 Fully Adhered Systems – Class C ................................................................................................................. 36 Maintenance and Repair Systems – Class A ............................................................................................... 37 General Notes: ...................................................................................................................................... 37 Maintenance and Repair Systems – Class B................................................................................................ 39 Maintenance and Repair Systems – Class C ................................................................................................ 41 Maintenance and Repair Systems – Class A, B or C .................................................................................... 41 UL Internal Fire Ratings ............................................................................................................................... 42 Roof Deck Constructions ........................................................................................................................ 42 "P" Assemblies...................................................................................................................................... 43 Factory Mutual General Information .......................................................................................................... 43 General Notations ....................................................................................................................................... 43 Page 2 June 20, 2018 Ground Roughness Definitions ................................................................................................................... 44 Exposure Category B .............................................................................................................................. 44 Exposure Category C .............................................................................................................................. 44 Exposure Category D .............................................................................................................................. 44 Field/Corner/Perimeter Definitions .......................................................................................................... 45 Perimeter and Corner Treatment of Adjoining Buildings ........................................................................ 46 Prescriptive Enhancement Options: Perimeter and Corner .................................................................... 46 Base Sheet Attachment .......................................................................................................................... 47 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck ......................................... 48 SBS – 3 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck ......................................... 51 SBS – 2 Ply – Hot Asphalt – Cover Board - Adhered/Insulation - Attached – Steel Deck...................... 53 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Adhered – Thermal Attached – Concrete Deck .. 54 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Adhered – Concrete Deck ................................... 54 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Concrete Deck .................................. 55 SBS/Ply – 3 Ply – Hot Asphalt – Cover Board/Insulation – Concrete Deck ........................................... 56 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation – LWIC Over Concrete Deck............................... 57 SBS – 2 Ply – Nailed Base Sheet – LWIC – Steel Deck ........................................................................ 59 SBS – 2 Ply – Nailed Base Sheet – LWIC – Form Deck ........................................................................ 59 SBS – Cap Torched – Base Sheet – Cover Board/Insulation Attached – Steel Deck ............................ 61 SBS – Cap Torched – Base Attached – Cover Board/Insulation Attached – Concrete Deck ................ 62 SBS – Cap and Base Torched – Cover Board/Insulation – Steel Deck.................................................. 62 SBS – Cap and Base Torched – Cover Board/Insulation Attached – Concrete Deck ............................ 63 SBS – Cap and Base Torched – Cover Board/Insulation Adhered – Concrete Deck ............................ 65 SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck............................ 65 SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Steel Deck .................................. 68 Built-Up Roof – Hot Asphalt – Cover Board/Insulation – Steel Deck ...................................................... 69 Built-Up Roof – Hot Asphalt – Cover Board/Insulation – Concrete Deck ............................................... 69 Built-Up Roof – Hot Asphalt – Cover Board/Insulation – LWIC .............................................................. 72 Built-Up Roof – Hot Asphalt – Base Sheet Attached – No Cover Board/Insulation – LWIC................... 72 APP – 2 Ply – Cap/Base Torched – Cover Board/Insulation Attached – Steel Deck ............................. 73 APP – 2 Ply – Cap Torched w/ MB Base – Cover Board/Insulation Attached – Steel Deck .................. 74 APP – 2 Ply – Cap/Base Torched – Cover Board/Insulation Attached – Concrete Deck ....................... 75 APP – 2 Ply – Cap Torched w/ MB Base – Cover Board/Insulation Attached – Concrete Deck ............ 75 APP – Hybrid – Cover Board/Insulation – Concrete Deck ...................................................................... 75 APP - Hybrid – 3 Ply – Cover Board/Insulation – LWIC Deck ................................................................ 76 Page 3 June 20, 2018 APP – 2 Ply – Cap/Base Cold – Cover Board/Insulation Attached – Steel Deck ................................... 76 SBS – 2 Ply – Cap/Base Cold – Cover Board/Insulation Attached – Steel Deck ................................... 77 SBS – 2 Ply – Cap/Base Cold – Cover Board Adhered/Insulation Attached – Steel Deck .................... 77 SBS – 2 Ply – MB Cold Adhesive – Cover Board/Insulation Attached – Concrete Deck ....................... 78 SBS – 2 Ply – MB Cold Adhesive – Cover Board/Insulation Adhered – Concrete Deck ........................ 78 SBS – 2 Ply – MB Cold Adhesive – No Cover Board/Insulation – Concrete Deck ................................. 79 APP –Torched – BaseGard SA– Cover Board/Insulation Attached – Steel Deck .................................. 80 APP –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck............................ 80 APP –Torched – BaseGard SA– Cover Board/Insulation Adhered – Concrete Deck ............................ 81 APP –Torched – BaseGard SA– No Insulation – Concrete Deck........................................................... 81 PP –Torched – BaseGard SA– Cover Board/Insulation – Concrete Deck – Re-Cover/Re-Roof ........... 82 Page 4 June 20, 2018 Underwriters Laboratories (UL) External Fire Ratings All regional building codes and most local building code officials require that roofing systems meet minimum performance requirements when exposed to external fire sources. The accepted method for measuring external fire Resistance is ASTM E-108. This test standard, and closely related standards such as Underwriters Laboratories UL-790 and Uniform Building Code 15-2, is used to determine the ability of a roof system to hinder the horizontal spread or vertical penetration of an external fire source. In accordance with these standards, all classified roof covering assemblies fall into one of the three following categories. CLASS A: Includes roof coverings which are effective against severe fire exposures CLASS B: Includes roof coverings which are effective against moderate fire exposures CLASS C: Includes roof coverings which are effective against light fire exposures Noncombustible Roof Decks (NC): Steel, Concrete, Poured Gypsum – require testing for horizontal spread of flame. Combustible Roof Decks (C): Wood, Plywood, Tectum – require testing for both horizontal spread and vertical penetration of flame. The following information has been referenced from the UL Online Certification Directory document: TGFU.GuideInfo Certified gypsum wallboard, any thickness, may be included in any roofing system without adversely affecting the certification. Insulations may be attached to the deck with fasteners, hot mopping asphalt or certified adhesive. Certified insulated systems may be installed over existing certified insulated systems when: 1. The new system is certified for use with the existing roof insulation type (glass fiber, perlite, wood fiber, foamed plastic, etc.), and 2. The total thickness of insulation in both systems does not exceed the maximum specified for the new system being applied. Maintenance and Repair Systems These roofing systems are composed of various types of roofing applications which are specifically limited for installation (recover) over existing roofing systems as specified. These systems may not meet certification requirements without being used over existing systems. Recovering may also be accomplished with certified new construction roofing systems where compatibility has been determined by test, by empirical data or by known performance properties of similar materials to the test methods. The following guidelines are provided to assist Authorities Having Jurisdiction in determining the suitability of a new construction roofing system as a recover system. Noncombustible Deck Construction 1. Insulated roof systems may be utilized over any type of existing roof system and maintain its new construction rating when the roof deck is noncombustible. 2. Insulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing roof system and maintain its new construction rating when the roof deck is noncombustible. The insulation may be omitted from the re-cover system. 3. Uninsulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing uninsulated roof system and maintain its new construction rating when the roof deck is noncombustible. Combustible Deck Construction 1. Insulated roof systems certified for use over combustible deck can be used over any type of existing roof system and maintain its new construction rating. 2. Insulated roof systems certified for use over noncombustible deck may be used over any type of Class A, B or C existing roof systems. The resultant Class will be the lesser rating of the existing system or the new construction (recover) system. 3. Uninsulated multiple-layered hot mopped, cold application or modified bitumen membrane new construction systems with a base ply of Type G1 or Type G2 may be used over any existing uninsulated roof system and maintain its new construction rating. Page 5 June 20, 2018 The class of roof covering required by each regional building code depends upon many factors, including the use and location of the building and the type of construction. The local building authority should always be consulted as to what the roofing assembly classification will need to be for each roofing project. It should be noted that these classifications apply to roofing assemblies, and NOT the roofing membrane. A roofing membrane that is classified as part of a Class A assembly when installed over a particular insulation may not qualify as part of a Class A assembly with another insulation. General Notations PLEASE NOTE: Not all UL-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and attachment for the warranty desired must be followed. If a discrepancy occurs between this guide and UL Certifications, the published information located in the UL Certifications Directory at www.ul.com should be adhered to and utilized. Noncombustible roof deck Classifications are applicable for use over combustible (15/32ʺ min. plywood) roof decks when ½ʺ (min.) gypsum board or ¼" (min.) Georgia-Pacific Gypsum LLC DensDeck® Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board are used directly over the deck with all joints staggered 6ʺ (min) from plywood joints. The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for approval of assembly for warranty purposes. References to Type G1 and Type G2 ply and base sheets include: Ply IV, Ply VI (Type G1), MB Base (Type G2) in any of the following Classifications. Firestone Channel Venting Base Sheet (Type G3) may be used in lieu of any Type G2 base in any applicable non-combustible Classification. The Firestone Channel Venting Base (mechanically attached only) may be used in all assemblies where the Firestone MB Base is listed on Non-combustible decks. SBS Poly Base sheet can be used in any non-combustible deck system which utilizes a Firestone SBS Cap. ISOGARD™ HD, ISOGARD HD Composite, and RESISTA™ are acceptable alternates to ISO 95+™ GL in any applicable Classification. I.S.O. FIX™ II Adhesive may be used in any of the following Classifications to adhere insulation to the roof deck. I.S.O. Spray™ R or Firestone I.S.O.Stick™/Twin Jet, and I.S.O. Twin Pack™ may be used in any of the following Classifications to adhere insulation to both non-combustible roof deck substrates and other insulation layers including wood fiberboard and Georgia-Pacific Gypsum LLC Georgia-Pacific Gypsum LLC DensDeck Roof board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board. Tapered ISO 95+ GL may be substituted for ISO 95+ GL in any of the systems listed below. ISO 95+ GL may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. SBS Glass is an acceptable alternate to SBS Cap, SBS Smooth, and SBS Premium in all applicable systems. SBS Smooth membrane may be used in any noncombustible system utilizing the above SBS membranes as an alternate to Type G1 or G2 base/ply sheets, provided the substitution occurs directly over wood fiber, glass fiber or perlite insulation only. The SBS Smooth membranes may be utilized in more than one layer. SBS Premium Base Sheet may be used in lieu of SBS Base or SBS Base-P sheet in any system incorporating the latter. SBS Poly Torch Base Sheet may be added to any applicable classified system without adversely affecting the existing Classification. It may also be used as a substitute for any base sheet in non-combustible deck roofing systems. SBS Base Sheet or SBS Base-P sheet may be used in lieu of MB Base Sheet in all applicable Classifications. AcryliTop™ Base Coat for Asphalt (1.5-gal²) and AcryliTop PC-100 (1-gal²) may be used over any of the following modified bitumen membranes: SBS FR Torch, SBS Premium FR, SBS Premium FR Torch, SBS Glass FR, SBS Glass FR Torch, APP 180 FR or APP Premium FR. Firestone MB Base, APP 80 Glass Base, APP 80 Glass Base-P, SBS Glass Torch Base, SBS Glass Torch Base 1.5 Square, Malarkey Premium I SBS Modified Base Sheet No. 501 and Intec/Permaglas Ultra Base are acceptable substitutes and may be used in any assembly which utilizes Type G1, Type G2, Johns Manville No. 28 Glass Base, Bird CRS base sheet or GAF-Glass Base Sheets. ISOGARD 95+ GL is trademarked. The following membranes are equivalent: a) b) c) d) e) f) SBS Premium FR, SBS Premium FR Torch, SBS FR Cap SBS Cap SBS Premium, SBS Premium Torch SBS Smooth SBS Glass, SBS Glass Torch SBS Glass FR, SBS Glass FR Torch Page 6 June 20, 2018 General System Variations – V-Force, Alternate Products or Application UL Assembly Number Deck Vapor Barrier Maximum Slope Roofing System Class, Type A/B/C, Mechanically 1. Attached or Fully Adhered NOTE 1: Classification (A, B or C) and maximum incline will be the same as that for the currently Classified insulated system, currently limited to a noncombustible deck. Insulation (Optional): Firestone ISO 95+ GL– Any Thickness Barrier Board: (Optional) A/B/C, ½ʺ min. DensDeck, DensDeck Prime C– V-Force, See Mechanically Roofing System: 1A. NOTE 1 Attached or 15/32 SelfAny Insulated UL Classified modified bitumen system, BUR Adhered Fully Adhered system, EPDM, or TPO membrane system. Insulation may be adhered or mechanically attached with Firestone I.S.O. Twin Pack, I.S.O.Stick or I.S.O. Spray R NOTE 1: Classification (A, B or C) and maximum incline will be the same as that for the currently Classified insulated system, currently limited to a combustible deck. Insulation (Optional): Firestone ISO 95+ GL– Any Thickness Insulation: (Optional) A/B/C, 1ʺ min. RESISTA C– V-Force, Mechanically Roofing System: 1B. ¼ʺ 15/32 SelfAttached or Any Insulated UL Classified modified bitumen system, BUR Adhered Fully Adhered system, EPDM, or TPO membrane system. Insulation may be adhered or mechanically attached with Firestone I.S.O. Twin Pack, I.S.O.Stick or I.S.O. Spray R NOTE 1: Classification (A, B or C) and maximum incline will be the same as that for the currently Classified insulated system, currently limited to a combustible deck. Any Insulated UL Classified modified bitumen system, BUR NC (Optional) (See V-Force, system, EPDM or TPO system. Insulation may be adhered NOTE 1) Self-Adhered with Firestone I.S.O. Twin Pack, I.S.O.Stick or I.S.O. Spray R UL Assembly Number Deck Vapor Barrier Roofing System See NOTE 1 Maximum Slope Class, Type Insulation: Any UL Classified, any thickness, adhered with Firestone A/B/C, NC I.S.O. Twin Pack, I.S.O.Stick or I.S.O. Spray R See Mechanically 2. (See None Membrane: NOTE 1 Attached or NOTE 1) Any UL Classified modified bitumen system, BUR system, Fully Adhered EPDM or TPO membrane system suitable for use with any roof insulation. NOTE 1: Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck. Insulation: Any UL Classified, any thickness, adhered with Firestone I.S.O. Twin Pack, I.S.O.Stick or I.S.O. Spray R Barrier Board: Gypsum wallboard, ½" thick min Georgia-Pacific Gypsum A/B/C, LLC DensDeck Roof board or DensDeck Prime Roof C– See Mechanically 2A. board or DensDeck DuraGuard Roof board, ¼ʺ min, joints None 15/32 NOTE 1 Attached or in barrier board offset 6ʺ with joints in deck. Fully Adhered Membrane: Any UL Classified modified bitumen system, BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or TRE membrane system suitable for use with any roof insulation. NOTE 1: Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck. Page 7 June 20, 2018 Asphalt Systems with Surfacing – Class A UL Assembly Deck Number 1. NC 2. NC 3. NC 4. C– 15/32 5. NC 6. NC Roofing System Insulation ISO 95+ GL, any thickness, mechanically fastened or adhered with hot mopping asphalt Ply Sheet Two to four layers, Type G1 or Type G2, any combination Surfacing Gravel Insulation HailGard, mechanically fastened or adhered with hot mopping asphalt, 1½ 3½ʺ thick Insulation (Optional) Perlite, 1ʺ thick Ply Sheet Three to four layers, Type G1 or Type G2, any combination Surfacing Gravel, slag or crushed stone Base Sheet MB Base, mechanically fastened or hot mopped Insulation (Optional) Any UL Classified (EPS must be covered with ½" thick min glass fiber, wood fiber or perlite), any thickness, mechanically fastened or hot mopped Ply Sheet One or more layers of MB Base or Type G1, any combination Surfacing Gravel, crushed stone or crushed slag, in a flood coat of hot roofing asphalt Insulation (Optional) Any UL Classified, any thickness Ply Sheet One or more plies Type G1, Type G2 or SBS Base sheet, mechanically fastened or hot mopped, any combination Membrane SBS Smooth, SBS Premium or SBS Cap (modified bitumen), hot mopped Surfacing Gravel, crushed stone or crushed slag, in a flood coat of asphalt Insulation (Optional) Any UL Classified, any thickness Ply Sheet One or more plies Type G1, Type G2 or SBS Base sheet, mechanically fastened or hot mopped, any combination Membrane SBS Smooth, SBS Premium or SBS Cap, hot mopped Surfacing Gravel, crushed stone or crushed slag, in a flood coat of asphalt Insulation (Optional) ISO 95+ GL or FiberTop B, wood fiberboard, Polyisocyanurate, fiberglass, perlite, any combination, any thickness, mechanically fastened, hot mopped or attached with any UL Classified cold adhesive Base Sheet (Optional) One or more plies MB Base Sheet, mechanically fastened or hot mopped Ply Sheet One or more plies Ply IV or Ply VI, mechanically fastened or hot mopped Surfacing Gravel, crushed stone or crushed slag in a flood coat of asphalt Maximum Slope Class 3ʺ A 3ʺ A 3ʺ A 1ʺ A 1½" A 3" A Page 8 June 20, 2018 Continued Asphalt Systems with Surfacing – Class A UL Assembly Number Deck Roofing System Insulation ISO 95+ GL, min 2ʺ (or 1½" ISO 95+ GL with min ½" FiberTop "B" or any UL Classified perlite min ½"), min 1ʺ wood fiberboard (includes FiberTop “B”) or min 1ʺ perlite, mechanically fastened, hop mopped or attached with any UL Classified cold adhesive C– 7. Base Sheet 15/32 One or more plies MB Base, mechanically fastened or hot mopped Ply Sheet: Two or more plies Firestone Ply IV or Ply VI, mechanically fastened or hot mopped Surfacing Gravel, crushed stone or crushed slag in a flood coat of asphalt Insulation Firestone ISO 95+ GL or any other UL Classified Polyisocyanurate, any thickness, mechanically fastened Insulation Any UL Classified wood fiberboard, ½" thick, mechanically fastened or C– adhered with hot mopping asphalt 8. 15/32 Ply Sheet MB Base, Ply IV, Ply VI or any other UL Classified Type G1 or Type G2, four plies, adhered with hot asphalt Surfacing Gravel, 400 lb² Insulation (Optional) ISO 95+ GL or any other UL Classified Polyisocyanurate, any thickness, mechanically fastened or adhered with hot mopping asphalt Insulation (Optional required if Polyisocyanurate is used) Any UL Classified wood fiberboard, ½" thick, mechanically fastened or 9. NC adhered with hot mopping asphalt Ply Sheet MB Base, Ply IV, Ply VI or any other UL Classified Type G1 or Type G2, max four plies, adhered with hot asphalt Surfacing Gravel, 400 lb² Insulation One or more layers ISO 95+ GL any thickness, nailed or adhered with hot roofing asphalt or hot roofing coal tar 10. NC Surfacing Gravel surfaced Class A, B or C asphalt organic, glass fiber, organic/glass fiber or coal tar felt system Insulation One or more layers ISO 95+ GL any thickness, nailed or adhered with hot roofing asphalt 11. NC Surfacing Any UL Classified A, B or C asphalt organic or glass fiber system surfaced with Owens-Corning Type G2 Perma Ply 28ʺ or Roll Roofing No. 45 or Type G3 Perma Cap NOTE: * Limited to that specified for classified system Insulation ISO 95+ GL, ½" thick min Insulation C– Wood fiberboard, ½" thick min 12. 15/32 Ply Sheet Four or more plies Type G1, hot mopped Surfacing Gravel, 400 lb² Maximum Slope Class 3ʺ A 4ʺ A 4ʺ A 3ʺ A See Note 1 A ¼ʺ A Page 9 June 20, 2018 Continued Asphalt Systems with Surfacing – Class A UL Assembly Number Deck 13. NC 17. C– 15/32 18. NC 19. NC Roofing System Insulation FiberTop B, or Structodek High Density Fiberboard, ½ʺ mechanically fastened with metal insulation anchors or hot mopped Base Sheet Three or more plies Type G1 asphalt glass fiber ply sheet Surfacing Gravel, crushed stone or slag Insulation ISO 95+ GL, RESISTA - any thickness, mechanically fastened or adhered with hot roofing asphalt, any combination Barrier Board Minimum ¼ʺ thick, Georgia-Pacific Gypsum LLC DensDeck Roof board or DensDeck Prime Roof board or DensDeck DuraGuard Roof Board Base Ply BASEGARD SA, self-adhered Intermediate Ply (Optional) SBS Premium Poly Base, MB Base, SBS Base, SBS Poly Base, SBS Premium Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Poly Torch Base, SBS Smooth mopped or torched Cap Ply SBS Premium FR Torch, SBS Premium FR, SBS FR, SBS FR Torch, SBS Glass FR and SBS Glass FR Torch, the membrane is either torched or mopped with hot asphalt to the base sheet or adhered with Firestone MultiPurpose MB Cold Adhesive Insulation ISO 95+ GL, RESISTA, ISOGARD HD Composite or ISOGARD HD, any thickness, - mechanically fastened Base Ply BASEGARD SA, self-adhered Intermediate Ply (Optional) SBS Premium Poly Base, MB Base, SBS Base, SBS Poly Base, SBS Premium Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Poly Torch Base, SBS Smooth - mopped or torched Cap Ply SBS Premium FR Torch, SBS Premium FR, SBS FR, SBS FR Torch, SBS Glass FR and SBS Glass FR Torch, the membrane is either torched or mopped with hot asphalt to the base sheet or adhered with Firestone MultiPurpose MB Cold Adhesive Base Sheet Channel Venting Base, MB Base, Ply IV, or Ply VI, mechanically fastened or hot mopped Insulation (Optional) Perlite or glass fiber, any thickness, mechanically fastened or hot mopped Ply Sheets One or more layers Channel Venting Base, MB Base, Ply IV, or Ply VI Surfacing Gravel, crushed stone or crushed slag, in a flood coat of hot roofing asphalt Maximum Slope Class 3ʺ A ½" A ¼ʺ A 3ʺ A Page 10 June 20, 2018 Continued Asphalt Systems with Surfacing – Class A UL Assembly Number Deck 20. NC 21. NC Roofing System Insulation ISO 95+ GL, RESISTA, ISOGARD HD, ISOGARD HD Composite any thickness, loose-laid or mechanically fastened Base Sheet One ply SBS Premium Poly Base, mechanically fastened Inter Ply Sheet One ply SBS Premium Poly Base, fully adhered with hot mopping asphalt Membrane UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) or UltraPly TPO XR 135 (80 mil), fully adhered with hot mopping asphalt Insulation ISO 95+ GL, RESISTA, any thickness, mechanically fastened Barrier Board Georgia-Pacific Gypsum LLC Dens Deck, ¼ʺ mechanically fastened Base Sheet: One ply SBS Premium Poly Base, mechanically fastened Ply Sheet One ply SBS Premium Poly Base, fully adhered with hot mopping asphalt Membrane UltraPly TPO XR 100 (45 mil), UltraPly TPO XR 115 (60 mil) or UltraPly TPO XR 135 (80 mil), fully adhered with hot mopping asphalt Maximum Slope Class ¼ʺ A ½" A Maximum Slope Class ½" B ½" B ½" B Asphalt Systems with Surfacing – Class B UL Assembly Number Deck 1. C– 15/32 2. C– 15/32 3. C– 15/32 Roofing System Base Sheet One layer MB Base, or SBS Base, mechanically fastened Ply Sheet (Optional) One layer MB Base, adhered with Multi-Purpose MB Cold Adhesive or LiquiGard Membrane Adhesive at 1.5-gal² Membrane One layer SBS Glass FR, adhered with Multi-Purpose MB Cold Adhesive or LiquiGard Membrane Adhesive at 1.5-gal² Base Sheet One layer MB Base, SBS Base or SBS Premium Base, mechanically fastened Ply Sheet One layer MB Base, or SBS Base sheet adhered with Multi-Purpose MB Cold Adhesive or LiquiGard Membrane Adhesive at 1.5-gal² Membrane One layer SBS FR Cap or SBS Premium FR, adhered with "Multi-Purpose MB Cold Adhesive" or LiquiGard Membrane Adhesive at 1.5-gal² Base Sheet 1 ply MB Base mechanically fastened. Membrane 1 ply APP 180 FR Cool fully adhered with Multi‐Purpose MB Cold Adhesive at 1.5‐gal² Page 11 June 20, 2018 Continued Asphalt Systems with Surfacing – Class B UL Assembly Number 4. Deck Roofing System Maximum Slope Class NC Insulation (Optional) ISO 95+ GL, FiberTop B, any thickness, or any UL Classified Polyisocyanurate, perlite, fiberglass or wood fiberboard, any combination, any thickness, mechanically fastened or hot mopped Base Sheet One layer SBS Base, SBS Poly Base, Ply IV, Ply VI, or MB Base sheet fully adhered with LiquiGard Membrane Adhesive at 1.5-gal² Membrane One or more SBS Cap FR or SBS Glass FR fully adhered with LiquiGard Membrane Adhesive at 1.5-gal² 1ʺ B Asphalt Systems with Surfacing – Class C UL Assembly Number 1. Deck Roofing System Maximum Slope Class NC Insulation (Optional) ISO 95+ GL, FiberTop B, any thickness, or any UL Classified Polyisocyanurate, perlite, fiberglass or wood fiberboard, any combination, any thickness, mechanically fastened or hot mopped Base Sheet One layer SBS Base, SBS Poly Base, Ply IV, Ply VI, or MB Base sheet fully adhered with LiquiGard Membrane Adhesive at 1.5-gal² Membrane One or more plies SBS Premium, SBS Smooth, SBS Metal Flash AL or SBS Glass fully adhered with LiquiGard Membrane Adhesive at 1.5-gal² 5ʺ C Combination Hot & Cold Systems – Class A UL Assembly Number 1. Deck Roofing System Maximum Slope Class NC Insulation Isocyanurate, perlite, isocyanurate/composite, wood fiber and glass fiber, any thickness, mechanically fastened or adhered with hot roofing asphalt, any combination Base Sheet One ply Type G1 or Type G2, mechanically fastened or sprinkle mopped. Ply Sheet Two or more plies Type G1 or Type G2, adhered with hot roofing asphalt Base Coat Firestone Fibered Asphalt Emulsion at 1.5-gal² Intermediate Coat AcryliTop Base Coat for Asphalt at 1.5- gal² Top Coat AcryliTop PC-100, 1-gal² 1ʺ A Page 12 June 20, 2018 Continued Combination Hot & Cold Systems – Class A UL Assembly Number 2. 2A. Deck Roofing System Maximum Slope Class NC Insulation Isocyanurate, perlite, isocyanurate/composite, wood fiber and glass fiber, any thickness, mechanically fastened or adhered with hot roofing asphalt, any combination Base Sheet One ply Type G1 (Firestone Ply IV or Ply VI) or G2 (Firestone MB Base), mechanically fastened or mopped with hot asphalt Ply Sheet Three or more plies Type 15, G1 or G2, adhered with hot roofing asphalt Surfacing Firestone Aluminum Fibered Asphalt Emulsion at 1.5-gal² 2ʺ A C– 15/32 Barrier Board Minimum ¼ʺ thick Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board, mechanically fastened Insulation (Optional) Isocyanurate, perlite, isocyanurate/composite, wood fiber and glass fiber, any thickness, mechanically fastened or adhered with hot roofing asphalt, any combination Base Sheet One ply Type G1 (Firestone Ply IV or Ply VI) or G2 (Firestone MB Base), mechanically fastened or sprinkle mopped with hot asphalt Ply Sheet Three or more plies Type 15, G1 or Type G2, or Firestone MB Base or Ply IV or Ply VI felts adhered with hot roofing asphalt Surfacing Firestone Aluminum Fibered Asphalt Emulsion at 1.5-gal² 2ʺ A Page 13 June 20, 2018 Continued Combination Hot & Cold Systems – Class A UL Assembly Number 3. 4. Deck Roofing System Maximum Slope Class C– 15/32 Insulation (Optional) ISO 95+ GL or RESISTA or ISOGARD HD Composite or any UL Classified Polyisocyanurate or perlite or wood fiber, any thickness, fully adhered with hot roofing asphalt, mechanically fastened or adhered with any UL Classified insulation adhesive Barrier Board (Not Required for Noncombustible Roof Decks) Minimum ¼ʺ thick, Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board or minimum ¼ʺ thick Untied States Gypsum Co. Securock® Roof Board (Type FRX-G) or Securock Glass-Mat Roof Board (Type SGMRX) or minimum ½" thick gypsum board with the butt joints in the barrier board staggered a minimum of 6ʺ from plywood deck joints; fully adhered with hot roofing asphalt or mechanically fastened or adhered with any UL Classified insulation adhesive Base Sheet 1 ply Soprema Inc.'s Sopralene 250 Sanded fully adhered with MultiPurpose MB Cold Adhesive applied at a rate of 1.5 to 2-gal/100 ft² Membrane SBS Premium FR or SBS Glass FR or BS Torch FR or SBS Glass FR Torch or SBS Premium FR Torch (modified bitumen) fully adhered with Multi-Purpose MB Cold Adhesive applied at a rate of x-gal/100 ft² or fully adhered with hot roofing asphalt or heat welded 1ʺ A NC Insulation ISO 95+ GL, RESISTA or ISOGARD HD Composite, hot mopped or mechanically fastened Cover Board (Optional) ½" ISOGARD HD, ¼", ½" or ⅝" thick United States Gypsum Co. Securock Glass-Mat Roof Board or Securock Gypsum-Fiber Roof Board or Georgia-Pacific Gypsum LLC DensDeck Prime® or DensDeck, cover board may be hot mopped attached with insulation adhesive or mechanically fastened. Base Sheet SBS Premium Poly Base adhered with Multi-Purpose MB Cold Adhesive Membrane SBS Premium FR, SBS Glass FR, SBS FR Torch, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet or adhered with Multi-Purpose MB Cold Adhesive 1½" A Page 14 June 20, 2018 Continued Combination Hot & Cold Systems – Class A UL Assembly Number 5. 6. Deck Roofing System Maximum Slope Class C– 15/32 Insulation (Optional) Any UL Classified Polyisocyanurate hot mopped or mechanically fastened Barrier Board ¼", ½" or ⅝" thick Untied States Gypsum Co. Securock Glass-Mat Roof Board or Securock Gypsum-Fiber Roof Board or Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board cover board may be hot mopped attached with insulation adhesive or mechanically fastened Base Sheet: SBS Premium Poly Base mopped or torched or adhered with MultiPurpose MB Cold Adhesive Membrane SBS Premium FR, SBS Glass FR, SBS FR Torch, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet or adhered with Multi-Purpose MB Cold Adhesive ½" A NC Insulation ISO 95+ GL any thickness, mechanically fastened or adhered with any UL Certified insulation adhesive Cover Board Minimum ½" thick UL Certified wood fiber board or minimum ¼ʺ thick Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board or United States Gypsum Co. Securock Gypsum-Fiber Roof Board (Type FRXG). The cover board may be mechanically attached or secured with hot roofing asphalt or UL Certified Insulation adhesive Ply Sheets Two or more plies of Ply IV, Ply VI or MB Base fully adhered with hot roofing asphalt Cap Membrane SBS FR, SBS Glass FR or SBS Premium FR, SBS FR Torch, SBS Glass FR Torch, SBS Premium FR Torch either mopped, torched or adhered with Multi-Purpose MB Cold Adhesive applied at a rate of 1.5gal/100 ft² ½" A Page 15 June 20, 2018 Combination Hot & Cold Systems – Class B UL Assembly Number 1. Deck Roofing System Maximum Slope Class NC Insulation ISO 95+ GL, RESISTA or ISOGARD HD Composite, hot mopped or mechanically fastened Barrier Board (Optional) ½" ISOGARD HD, ¼", ½" or ⅝" thick Securock Glass-Mat Roof Board or Securock Gypsum-Fiber Roof Board, Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board, cover board may be hot mopped attached with insulation adhesive or mechanically fastened Base Sheet SBS Premium Poly Base adhered with Multi-Purpose MB Cold Adhesive Membrane SBS Premium FR, SBS Glass FR, SBS FR Torch, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet or adhered with Multi-Purpose MB Cold Adhesive 2ʺ B Any UL Classified Modified Bitumen Systems – Class A, B or C UL Assembly Number Deck 1. NC See NOTE 1 3. NC See NOTE 1 Roofing System Insulation Any UL Classified, any thickness, adhered with Twin Jet or Quick Dual Membrane Any UL Classified modified bitumen system, BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or TRE membrane system suitable for use with any roof insulation NOTE 1 Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck Insulation Any UL Classified, any thickness, adhered with I.S.O. Spray R or I.S.O. Spray R-SAF Membrane Any UL Classified modified bitumen system, BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or TRE membrane system suitable for use with any roof insulation NOTE 1 Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck Maximum Slope Class See NOTE 1 A/B/C See NOTE 1 See NOTE 1 A/B/C See NOTE 1 Page 16 June 20, 2018 Ballasted Systems – Class A UL Assembly Number Deck 5. C– 15/32 6. NC 7. C– 15/32 Maximum Class Slope Roofing System Insulation (Optional) Perlite, glass fiber, isocyanurate, any ISO 95+ GL/ISOGARD Base Sheet GAF Base sheet, Johns Manville GlasBase or Firestone MB Base, mechanically attached or hot mopped Membrane APP 160 or APP 170 (modified bitumen), heat fused Surfacing Gravel or slag loose laid or set in hot roofing asphalt. Insulation (Optional) HailGard Composite Board, Perlite, glass fiber, wood fiber, isocyanurate, any ISO 95+ GL insulation, urethane or composite, any thickness Base Sheet (Optional) Type G1, G2 or G3 Membrane APP 160 or APP 170 (modified bitumen), heat fused Surfacing Gravel or slag, loose laid or set in hot roofing asphalt Insulation (Optional) Perlite, glass fiber, wood fiber, isocyanurate, any ISO 95+ GL insulation or any other UL Classified insulation, any combination Base Sheet (Optional): Type G1, G2 or G3 or Firestone Protection Mat (not UL Classified) Membrane APP 160 or APP 170 (modified bitumen), heat fused or any UL Classified PVC, EPDM, CPE, CSPE, TRE, nitrile alloy or modified bitumen Insulation (Optional): Dow Chemical STYROFOAM RM, PD, SM, TG or STYRORIB, 1ʺ min. When the insulation is applied in more than one layer, successive layers shall be installed without attachment to the preceding layer Slip Sheet (Optional) Fiberglas mat may be laid between the insulation and membrane Scrim (Optional) Fabrene, International Paper D689 or Rufon Polypropylene, 2 oz/yd² (not Classified). Surfacing One of the following: a.) 900 lb² min of crushed stone or river bottom stone which is free from dirt and graded to a typical size of ¾ʺ with a min of ½" for crushed stone and ¾" to 1¾" for river bottom stone. b.) Concrete blocks weighing not less than 10 lb/ft² and spread not more than ⅛" apart 1½" A 1ʺ A 2ʺ A Page 17 June 20, 2018 Continued Ballasted Systems – Class A UL Assembly Number Deck 8. C– 15/32 9. C– 15/32 Maximum Class Slope Roofing System Insulation (Optional) Perlite, glass fiber, wood fiber, polyisocyanurate, urethane or composite, any thickness Base Sheet (Optional) Type G1, Type G2 or Type G3 Membrane APP 160 or Firestone APP 170 (modified bitumen). Insulation Dow Chemical STYROFOAM RM, PD, SM, TG or STYRORIB, 1ʺ min. When the insulation is applied in more than one layer, successive layers shall be installed without attachment to the preceding layer Slip Sheet (Optional) Fiberglas mat may be laid between the insulation and membrane Scrim (Optional) Fabrene, International Paper D689 or Rufon Polypropylene, 2 oz/yd² (not Classified). Surfacing Dow Chemical STYROFOAM panels surfaced with a min of ⅜" thick concrete mortar panels to be abutted together Insulation Any Firestone ISO 95+ GL insulation, any thickness, loose laid or mechanically fastened Membrane Fire Retardant RubberGard (EPDM), 45 or 60-mil, UltraPly TPO, any color, APP 160 or Firestone APP 170, (modified bitumen) or any UL Classified CPE, EPDM, LSPE, PVC, TRE, Nitrile alloy or modified bitumen, loose laid or mechanically fastened Surfacing River bottom stone (¾" to 1½" diameter), 1000 lb² 3" A 2" A Fully Adhered Systems – Class A UL Assembly Number 25. Deck Roofing System Maximum Slope Class NC Insulation (Optional) Perlite, glass fiber, wood fiber, isocyanurate, phenolic, foam glass, urethane or composite, any thickness Base Sheet Type G1, Type G2 or Type G3 Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97 or No. 169, applied at 1 gal² or No. 97 AF 1" A Page 18 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number 27. 30. Maximum Class Slope Deck Roofing System NC Insulation One or more layers UL Classified polystyrene, min 1ʺ thick Insulation One layer min ½" wood fiber board Base Sheet One or more layers OCF No. 28 base sheet, hot mopped, cold application adhesive or mechanically attached Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Coating Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak No. 97 applied at 1-gal² or No. 97 AF, applied at 1.5-gal² ¼" A C– 15/32 Insulation Any UL Classified, any thickness Barrier Board Water Resistant wallboard, ½" nom, joints in wallboard offset 6ʺ with joints in deck (may be placed above or below insulation) Base Sheet Type G1, Type G2 or Type G3 Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Coating Firestone Aluminum Fibered Roof Coating, 1½ gal², Karnak Chemical No. 97 or No. 169, applied at 1 gal² or No. 97 AF, applied at 1.5-gal² 1ʺ A ½" A 1ʺ A 31. C– 15/32 32. NC Insulation Any UL Classified, any thickness. Barrier Board Regular wallboard, ½" nom, joints in wallboard offset 6ʺ with joints in deck (may be placed above or below insulation). Base Sheet Type G1, Type G2 or Type G3. Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Coating Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97 or No. 169, applied at 1-gal² or No. 97 AF, applied at 1.5-gal² Insulation (Optional) Perlite, glass fiber, wood fiber, phenolic, isocyanurate, urethane or composite, any thickness Base Sheet Type G1, Type G2 or Type G3. Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Coating Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97 AF, 1.5-gal² Page 19 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number 40. 42. 43. 55. Maximum Class Slope Deck Roofing System NC Vapor Retarder (Optional): Type G2 base sheet GlasBase or UL Classified vapor retarder Insulation (Optional) One or more layers or combination of the following: polyisocyanurate, perlite, glass fiber or wood fiber insulation, any thickness Base Sheet One layer Type G2 GlasBase base sheet Membrane One layer Firestone APP 180-P, or APP 180 P (¾ sq or 1 sq), (modified bitumen), heat fused or Firestone SBS, (modified bitumen) hot mopped Surfacing Firestone Aluminum Fibered Roof Coating, 1½ gal², APOC No. 212 Fibrated Aluminum at 1.5-gal. 100 ft² or Karnak No. 97 Fibrated Aluminum roof coating at 1.5-gal/ft² 1ʺ A NC Base Sheet Type G1, Type G2, Type G3 or vented base sheet, mechanically fastened or hot mopped Membrane Firestone SBS Glass FR (modified bitumen), hot mopped in place 1ʺ A NC Insulation (Optional) Any UL Classified, any thickness. When polystyrene (EPS) is used, a min ½" thick layer of wood fiber or perlite must cover the EPS Base Sheet Type G1, Type G2 or Type G3, mechanically fastened or hot mopped Membrane Firestone SBS Glass FR” (modified bitumen), hot mopped in place 1ʺ A NC Insulation (Optional) Any UL Classified, any thickness (EPS must be covered with ½" min wood fiber, glass fiber or perlite) Base Sheet One or more plies Type G1, G2 or G3, Firestone MB Base or SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) Firestone SBS Smooth mechanically fastened or hot mopped Membrane One or more plies SBS Glass FR, SBS, SBS Premium or SBS Smooth, (modified bitumen), hot mopped. Surfacing Gravel 1½" A Page 20 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number save56. 57. 58. Deck Roofing System Maximum Slope Class C– 15/32 Insulation (Optional) Any UL Classified, any thickness (EPS must be covered with ½" min wood fiber, glass fiber or perlite) Base Sheet One or more plies Type G1, Type G2 or Type G3, Firestone MB Base or SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) One or more plies Firestone SBS Smooth, mechanically fastened or hot mopped Membrane One or more plies Firestone SBS Glass FR, SBS, SBS Premium or SBS Smooth (modified bitumen), hot mopped Surfacing Gravel 1ʺ A NC Insulation (Optional) Any UL Classified, any thickness (EPS must be covered with ½" min wood fiber, glass fiber, gypsum wallboard or perlite) Base Sheet: One or more plies Type G1, Type G2 or Type G3, or Firestone SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped. Ply Sheet (Optional) One or more plies Firestone SBS Smooth, mechanically fastened or hot mopped. Membrane One or more plies Firestone SBS, SBS Premium or SBS Smooth, hot mopped Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97, 1-gal² or No. 97AF, 1.5-gal² 1ʺ A C– 15/32 Base Sheet Two or more plies Type G2 (25 lb² min.) or Firestone SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) One or more plies Firestone SBS Smooth, mechanically fastened or hot mopped. Membrane One or more plies Firestone SBS, SBS Premium or SBS Smooth, hot mopped Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97, 1 gal² or No. 97AF, 1.5-gal² ½" A Page 21 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 59. C– 15/32 60. NC 61. C– 15/32 Roofing System Maximum Slope Class ½" A ½" A ½" A Insulation Polyisocyanurate, urethane, polyisocyanurate/perlite composite, urethane/perlite composite, 2ʺ thick min, glass fiber, wood fiber or perlite, 1ʺ thick min, joints in insulation offset 6ʺ with joints in deck. Insulations requiring a min thickness of 2ʺ may be used in a 1½ thickness if covered with ½" thick layer of wood fiber, glass fiber, perlite or gypsum wallboard Base Sheet One or more plies Type G2 or Firestone SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) One or more plies Firestone SBS Smooth, mechanically fastened or hot mopped Membrane One or more plies Firestone SBS, SBS Premium or SBS Smooth (modified bitumen), hot mopped Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No 97, 1-gal² or No 97AF, 1½ ga Insulation (Optional) Any UL Classified, any thickness. (EPS must be covered with ½" thick min wood fiber, glass fiber, perlite or gypsum wallboard) Base Sheet One or more plies Type G1, Type G2, Type G3 or Firestone MB Base, mechanically fastened or hot mopped. Membrane Firestone BS Premium FR (modified bitumen), hot mopped Insulation Wood fiber, 1ʺ thick min, glass fiber, 15/16ʺ thick min, perlite, ¾" thick min, polyisocyanurate, phenolic, urethane, polyisocyanurate/perlite composite or urethane/perlite composite, 2" thick min or polyisocyanurate, phenolic, urethane, polyisocyanurate/perlite composite or urethane/perlite composite, min 1½" covered with: 1.) Wood fiber, ½" min; 2.) Perlite, ½" min; 3.) Gypsum, ½" min; 4.) Fiberglass, ½" min. Joints in insulation offset 6" with joints in deck Ply sheet One or more plies Type G2 (26 lb² min), Firestone MB Base Sheet (26lb² min) or SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply sheet (Optional) One or more plies Firestone SBS Smooth, or Type G1, hot mopped or mechanically fastened Membrane Firestone SBS Glass FR (modified bitumen), hot mopped Page 22 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 62. C– 15/32 63. NC 65. NC 67. NC Maximum Class Slope Roofing System Ply Sheet Two or more plies Type G2 (25 lb² min), Firestone MB Base Sheet (26 lb² min) or SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) One or more plies Firestone SBS smooth, hot mopped or mechanically fastened Membrane Firestone SBS Glass FR (modified bitumen), hot mopped Insulation (Optional) Any UL Classified, any thickness (EPS must be covered with ½" min wood fiber, glass fiber or perlite) Base Sheet One or more plies Type G1, Type G2 or Type G3, or Firestone SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) One or more plies Firestone SBS Smooth, mechanically fastened or hot mopped Membrane One or more plies Firestone SBS Glass FR (modified bitumen), hot mopped Insulation Polyisocyanurate, glass fiber, perlite, wood fiber, hot mopped or mechanically fastened, any thickness Base Sheet Type G2, mechanically fastened or hot mopped Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Henry “Henry 520 Aluminum” applied at 1.5- gal² Insulation (Optional) Any thickness, one or more layers UL Classified perlite, wood fiber, glass fiber, polyisocyanurate, polyisocyanurate/composite, EPS/wood fiber, EPS/perlite, EPS/composite or Partek Insulation “PAROC” roof insulation Base Sheet One or more layers Type G1 or Type G2 Membrane One or more layers Firestone APP 160, APP 160-P, or Firestone APP 170 (modified bitumen), heat fused Surfacing Fields F530 Heat Shield Aluminum Coating or F630 Heat Shield Fibered Aluminum Coating, 1.5-gal² ½" A 1ʺ A ½" A 1ʺ A Page 23 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 68. NC 69. NC 77. C– 15/32 78. C– 15/32 83. NC Maximum Class Slope Roofing System Insulation (Optional) Any UL Classified, any thickness. (EPS must be covered with ½" min wood fiber, glass fiber or perlite) Base Sheet One or more plies Type G1, Type G2 or Type G3 Ply Sheet (Optional): One or more plies Firestone APP 160 or APP 170, heat fused Membrane Firestone APP 180 FR, heat fused Insulation (Optional) Any UL Classified, any thickness. (EPS must be covered with ½" min wood fiber, glass fiber, perlite or gypsum wallboard) Base Sheet One or more plies Type G1, Type G2 or Type G3 or Firestone MB Base Sheet, mechanically fastened or hot mopped Membrane Firestone SBS Premium FR (modified bitumen), hot mopped Insulation (Optional) Perlite or glass fiber, 15/16" thick min, or polyisocyanurate, 2" thick min, joints in insulation offset 6ʺ with joints in deck Base Sheet Two or more plies MB Base (Type G2) or any Type G2 weighing a min of 23 lb², mechanically fastened, spot or fully mopped Ply Sheet (Optional) Firestone APP 160 or APP 170 (modified bitumen), heat fused Membrane Firestone APP 180 FR (modified bitumen), heat fused Insulation (Optional) Perlite or glass fiber, 15/16ʺ thick min, or polyisocyanurate, 2ʺ thick min, joints in insulation offset 6ʺ with joints in deck Base Sheet Two or more plies MB Base (Type G2) or any Type G2 weighing a min of 23 lb², mechanically fastened, spot or fully mopped Ply Sheet (Optional): Firestone APP 160 or APP 170 (modified bitumen), heat fused Membrane Firestone APP 180 FR (modified bitumen), heat fused Insulation (Optional) Glass fiber or perlite, 1ʺ max, mechanically fastened Membrane: One layer Firestone SBS Metal Flash-AL (modified bitumen), heat fused or hot mopped. 2ʺ A ½" A ½" A ½" A 1ʺ A Page 24 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 84. NC 85. C– 15/32 86. C– 15/32 NC 97. Maximum Class Slope Roofing System Insulation (Optional) Polyisocyanurate, polyisocyanurate/perlite composite, phenolic, phenolic/perlite composite, glass fiber, wood fiber or perlite, any combination, any thickness and/or EPS covered with min 1ʺ perlite, wood fiber or 15/16ʺ glass fiber Base Sheet Type G2, one or more plies Membrane Firestone SBS Metal Flash-AL (modified bitumen), heat fused Insulation Polyisocyanurate, 1½" thick min, joints in insulation offset 6ʺ with joints in deck Base Sheet One or more plies Type G2, mechanically fastened, spot or fully mopped. Membrane Firestone SBS Metal Flash-AL (modified bitumen), heat fused Insulation Perlite or glass fiber, 1ʺ thick min, joints in insulation offset 6ʺ with joints in deck. Base Sheet One or more plies Type G2, mechanically fastened, spot or fully mopped Base/Ply Sheet One or more plies Type G2, hot mopped in place Membrane Firestone SBS Metal Flash-AL (modified bitumen), heat fused Insulation (Optional) Firestone ISO 95+ GL, Firestone FiberTop™ B, any thickness or any UL Classified polyisocyanurate, perlite, fiberglass or wood fiberboard, any thickness, mechanically fastened, hot mopped or adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² Base Sheet One layer Firestone Ply IV or Ply VI, Firestone MB Base, Firestone SBS Base or SBS Base-P sheet, Firestone SBS Premium Base, Firestone SBS Smooth, or any UL Classified Type G1 or Type G2, mechanically fastened or adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² or LiquiGard™ Membrane Adhesive at 1.5-gal² Membrane Firestone SBS Glass FR, SBS Premium FR adhered with Firestone MultiPurpose MB Cold Adhesive” at 1.5-gal² or LiquiGard Membrane Adhesive at 1.5-gal² Unlimited A Unlimited A Unlimited A ½" A Page 25 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 98. C– 15/32 100. C– 15/32 101. NC 102. C– 15/32 103. NC 104. C– 15/32 Maximum Class Slope Roofing System Base Sheet One layer Firestone MB Base, SBS Base or SBS Base-P sheet or SBS Premium Base, mechanically fastened Ply Sheet One layer MB Base or SBS Base or SBS Base-P sheet, SBS Premium Base, adhered with Firestone Multi-Purpose MB Cold Adhesive or LiquiGard Membrane Adhesive at 1.5-gal² Membrane Firestone SBS Glass FR, adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² or LiquiGard Membrane Adhesive at 1.5-gal² Barrier Board Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board ¼ʺ thick min or gypsum wallboard, ½ʺ thick min. Membrane Firestone APP 180 or APP 180-P (modified bitumen), heat fused Barrier Board (Optional) Minimum ¼ʺ thick Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board or gypsum wallboard, any thickness Membrane Firestone APP 180 (modified bitumen), heat fused Barrier Board Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board ¼" thick min or gypsum wallboard, ½ʺ thick min. Base Sheet Type G2, hot mopped or mechanically attached. Membrane Firestone APP 180 or APP 180-P (modified bitumen), heat fused Barrier Board (Optional) Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board or gypsum wallboard, any thickness Base Sheet Type G2, hot mopped or mechanically attached Membrane Firestone APP 180 or APP-180 P (modified bitumen), heat fused Base Sheet One or more layers Firestone MB Base (Type G2), mechanically fastened or hot mopped Ply Sheet Two or more layers Firestone Ply IV or Ply VI (Type G1) ply sheets, mechanically fastened or hot mopped Membrane One or more layers Firestone SBS Premium FR (modified bitumen), hot mopped or SBS FR Torch, (modified bitumen), heat fused ½" A ½ʺ A ½" A ¼" A ¼" A ½ʺ A Page 26 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 121. C– 15/32 122. NC 126. NC 133. C– 15/32 Maximum Class Slope Roofing System Base Sheet One or more layers Firestone MB Base, (Type G2), mechanically fastened Ply Sheet One or more layers Firestone Ply IV or Ply VI (Type G1), hot mopped Cap Sheet One layer Firestone SBS Premium FR, (modified bitumen), hot mopped Insulation (Optional) Any UL Classified polyisocyanurate, wood fiber, glass fiber or perlite, DensDeck, USG United States Gypsum Co. Securock any thickness, hot mopped or mechanically fastened Base Sheet Firestone SBS Poly Torch Base, heat fused or SBS Poly Base hot mopped Ply Sheet (Optional) One or more layers Firestone Ply IV, Ply VI, MB Base, SBS Base or SBS Base-P sheet, SBS Smooth, SBS Premium Base Sheet, hot mopped or SBS Poly Torch Base Sheet or SBS Poly Base then overlap is heat fused Membrane One or more layers Firestone SBS Premium FR (modified bitumen), hot mopped or SBS FR Torch, (modified bitumen), heat fused Insulation (Optional) Firestone ISO 95+ GL, any thickness, mechanically attached Base Sheet One layer Firestone BaseGard™ SA self-adhered Membrane Firestone SBS Premium FR, SBS Premium FR Torch, SBS FR Torch, SBS Glass FR, SBS Glass FR Torch, APP 180 FR, hot mopped or heat fused Insulation (Optional) Firestone ISO 95+ GL, any thickness, or any other UL Classified polyisocyanurate, any thickness, loose-laid or mechanically fastened Barrier Board Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board, min ¼ʺ thick, mechanically fastened Base Sheet Firestone SBS Glass Torch Base or SBS Glass Torch Base 1.5 Square heat fused or any other UL Classified Type G1 or Type G2, hot mopped or mechanically fastened Membrane Firestone SBS Metal Flash-AL, heat fused ½" A ½ʺ A ½ʺ A Unlimited A Page 27 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 134. NC 189. NC 192. NC 193. C– 15/32 Maximum Class Slope Roofing System Insulation (Optional) Any UL Classified except polystyrene (extruded and expanded), any combination, any thickness Base Sheet One or more plies Firestone MB Base, Ply IV or Ply VI, mechanically fastened or adhered with Firestone Multi-Purpose MB Cold Adhesive, 1.5-gal² Ply Sheet (Optional) Firestone APP 160 Cool or APP 170 Cool, mechanically fastened or adhered with Firestone Multi-Purpose MB Cold Adhesive, 1.5-gal² Membrane Firestone APP 180 FR Cool, heat fused or adhered with Firestone MultiPurpose MB Cold Adhesive, 1.5-gal² Base Coat (Optional) Firestone ACRYLIC Base Coat for Asphalt, 1.5-gal² Surfacing (Optional) Firestone AcryliTop PC-100, 1-gal² Insulation Perlite, glass fiber or wood fiber, any thickness Base Sheet Type G-2, mechanically fastened Membrane Firestone APP 160-P or APP 180-P, heat fused Surfacing Karnak Chemical Corp.'s Karnak No. 97 Fibrated Aluminum Roof Coating, 1.5-gal² Insulation Firestone ISO 95+ GL, RESISTA, ISOGARD HD any thickness Base Sheet Firestone BASEGARD SA, self-adhered Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet Insulation (Optional) Firestone ISO 95+ GL, RESISTA any thickness Barrier ¼ʺ DensDeck Base Sheet Firestone BASEGARD SA, self-adhered Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet 1ʺ A ¼" A ¼" A ¼" A Page 28 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number Deck 194. NC 195. C– 15/32 196. C– 15/32 197. C– 15/32 Maximum Class Slope Roofing System Insulation Firestone ISO 95+ GL, RESISTA, ISOGARD HD any thickness Base Sheet Firestone BASEGARD SA sheet that is self-adhered to the ISO Ply Sheet (Optional) Firestone SBS Base, SBS Premium Base, MB Base, SBS Glass Torch Base or SBS Glass Torch Base 1.5 Square, (Ply sheet is either mopped or torched to self-adhered base sheet) Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet Insulation (Optional) Firestone ISO 95+ GL, RESISTA, ISOGARD HD any thickness Barrier Board ¼ʺ DensDeck Base Sheet Firestone BASEGARD SA, self-adhered Ply Sheet (Optional) Firestone SBS Base, SBS Premium Base, MB Base, SBS Glass Torch Base or SBS Glass Torch Base 1.5 Square, (Ply sheet is either mopped or torched to self-adhered base sheet) Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet Insulation Minimum 1ʺ Firestone RESISTA Base Sheet Firestone BASEGARD SA sheet that is self-adhered to the insulation Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet Insulation Minimum 1ʺ Firestone RESISTA mechanically fastened Base Sheet Firestone SBS Poly Base, mechanically attached Interply Firestone BASEGARD SA - self adhered Cap Firestone SBS Premium FR Torch, SBS Premium FR, SBS FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet ¼" A ¼" A ¼" A ¼" A Page 29 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number 198. 199. 200. 202. Deck Maximum Class Slope Roofing System Base Firestone MB Base C– Interply 15/32 Firestone BASEGARD SA Cap Firestone SBS Premium FR Torch Cap Insulation Firestone ISO 95+ GL or Any UL Classified polyisocyanurate, perlite, fiberglass or wood fiberboard, any combination, any thickness, mechanically fastened. NC Base Firestone BASEGARD SA - Self Adhered Cap Firestone SBS FR Torch Insulation Firestone ISO 95+ GL or Any UL Classified polyisocyanurate, perlite, fiberglass or wood fiberboard, any combination, any thickness, mechanically fastened. NC Base Firestone BASEGARD SA - Self Adhered Cap Firestone SBS Glass FR Torch Insulation (Optional) Firestone ISO 95 + GL or RESISTA or ISOGARD HD Composite or any UL Classified polyisocyanurate or perlite or wood fiber, any thickness, fully adhered with hot roofing asphalt, mechanically fastened or adhered with any UL Classified insulation adhesive. Cover Board (Not Required for Noncombustible Roof Decks) Minimum ¼ʺ thick, Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board or minimum ¼ʺ thick Untied States Gypsum Corp. Securock Roof Board (Type FRX-G) or C– Securock Glass-Mat Roof Board (Type SGMRX) or minimum ½ʺ thick gypsum 15/32 board with the butt joints in the barrier board staggered a minimum of 6ʺ from plywood deck joints; fully adhered with hot roofing asphalt or mechanically fastened or adhered with any UL Classified insulation adhesive. Base Sheet 1 ply Soprema Inc.'s Sopralene 250 Sanded or Sopralene Flam 250 mechanically fastened or fully adhered with hot roofing asphalt or heat welded Membrane Firestone SBS Premium FR or SBS Glass FR or SBS Torch FR or SBS Glass FR Torch or SBS Premium FR Torch (modified bitumen) fully adhered with hot roofing asphalt or heat welded. ½ʺ A 1ʺ A 1ʺ A ½ʺ A Page 30 June 20, 2018 Continued Fully Adhered Systems – Class A UL Assembly Number 214. Maximum Class Slope Deck Roofing System NC Insulation Firestone ISO 95 + GL, RESISTA or ISOGARD HD Composite, hot mopped or mechanically fastened. Barrier Board ¼", ½" or ⅝" thick United States Gypsum Co. Securock Glass-Mat Roof Board or Securock Gypsum-Fiber Roof Board, Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck Prime Roof Board or DensDeck DuraGuard Roof Board, cover board may be hot mopped attached with insulation adhesive or mechanically fastened. Base Sheet Firestone BASEGARD SA self-adhered Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet. 1½ʺ- A Fully Adhered Systems – Class B UL Assembly Number Deck 3. C– 15/32 5. C– 15/32 Roofing System Insulation (Optional) Perlite, glass fiber, isocyanurate, any ISO 95+ GL insulation, urethane or composite, any thickness. Base Sheet or Insulation Two layers Type G2 or Johns Manville No. 28, or any UL Classified insulation (except EPS), 1ʺ min, optionally covered with ½ʺ min wood fiberboard, ½ʺ min gypsum wallboard, ½ʺ min perlite or 11/16ʺ min glass fiber may be substituted for one layer of No. 28 Base Sheet. Membrane Firestone APP 160, Firestone APP 170 or Monoply Plus (modified bitumen), heat fused Surfacing Karnak Chemical No. 97 Fibered Coating applied at 1 gal² or No. 97 or Firestone Aluminum Fibered Roof Coating, applied at 1.5-gal² Insulation (Optional) Perlite, fiber glass, wood fiber, isocyanurate, any ISO 95+ GL insulation, phenolic, foam glass, urethane or composite, any thickness. Base Sheet Johns Manville No. 28, GlasBase Bird CRS base or GAF-Glas, hot mopped, cold application adhesive or mechanically fastened. Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Cap Sheet Bird CRS Cap Sheet, OCF Cap Sheet, GAF GAFGLAS Mineral Surfaced Cap Sheet or Johns Manville GlasKap, hot mopped or adhered with Karnak Chemical cold application adhesive No. 81 Maximum Slope Class ¼ʺ B 2ʺ B Page 31 June 20, 2018 Continued Fully Adhered Systems – Class B UL Assembly Number Deck 6. C– 15/32 8. C– 15/32 9. C– 15/32 10. C–5/8 TG 11. C– 15/32 Roofing System Base Sheet Two layers Johns Manville No. 28, GlasBase or GAF GAFGLAS (Type G2), hot mopped, cold application adhesive or mechanically fastened Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Karnak Chemical No. 97, applied at 1-gal² Insulation Any UL Classified polyisocyanurate, 1ʺ thick min. Base Sheet Two layers Type G2 or one layer UL Classified Type VI ply sheet, mechanically fastened or hot mopped Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Karnak Chemical Karnak No. 97, 1.5-gal² Insulation (Optional) Any UL Classified, polyisocyanurate, perlite/polyisocyanurate composite, phenolic, glass fiber, wood fiber or perlite, or polystyrene (EPS) covered with a min ½ʺ thick layer of glass fiber, wood fiber or perlite. Joints in insulation offset 6ʺ with joints in deck Base Sheet One or more plies Type G2 (26 lb²), Firestone MB Base (26 lb²) or SBS Base or SBS Base-P sheet, mechanically fastened or hot mopped Membrane SBS Glass FR (modified bitumen), hot mopped in place Base Sheet One or more layers Type G2 (23 lb² min), Firestone MB Base Sheet (23 lb² min), hot mopped or mechanically attached Membrane One or more layers Firestone APP 160, Firestone APP 170 or Firestone APP 180 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97AF, 1½ gal² or No. 97, 1.5-gal² Insulation (Optional) Any thickness, one or more layers UL Classified perlite, glass fiber, polyisocyanurate, polyisocyanurate/composite or Partek Insulation PAROC roof insulation Base Sheet One or more layers Type G2 Membrane One or more layers Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Fields F530 Heat Shield Aluminum Coating or F630 Heat Shield Fibered Aluminum Coating, 1.5-gal² Maximum Slope Class ½ʺ B ¼" B ½ʺ B ½ʺ B ½" B Page 32 June 20, 2018 Continued Fully Adhered Systems – Class B UL Assembly Number Deck 12. C– 15/32 13. C– 15/32 15. C– 15/32 16. C– 15/32 17. C– 15/32 Roofing System Base Sheet One or more plies Type G2 (25 lb² min) or Firestone MB Base, mechanically attached or hot mopped. Ply Sheet (Optional) One or more plies Firestone APP 160 or Firestone APP 170, heat fused. Membrane Firestone APP 180 FR, heat fused Insulation Any UL Classified polyisocyanurate, perlite/polyisocyanurate composite, min 1½ʺ; wood fiber, min 1ʺ; perlite, min ¾ʺ; glass fiber, min 15/16ʺ, hot mopped or mechanically attached Insulation (Optional) Any UL Classified wood fiber, perlite, glass fiber, min ½ʺ, hot mopped or mechanically attached Base Sheet One or more plies Type G2 (25 lb² min) or Firestone MB Base Sheet, mechanically attached or hot mopped Ply Sheet (Optional): One or more plies Firestone APP 160 or Firestone APP 170, heat fused Membrane “Firestone APP 180 FR”, heat fused Base Sheet One or more plies Type G2, mechanically fastened, spot or fully mopped Base/Ply Sheet One or more plies Type G2, hot mopped. Membrane Firestone “BS Metal Flash-AL (modified bitumen), torched Insulation Perlite or glass fiber, ¾ʺ thick min, joints in insulation offset 6ʺ with joints in deck Base Sheet One or more plies Type G2, mechanically fastened, spot or fully mopped. Membrane Firestone SBS Metal Flash-AL (modified bitumen), torched Base Sheet One layer Firestone MB Base, SBS Base or SBS Base-P sheet or SBS Premium Base Sheet, mechanically fastened Ply Sheet (Optional) One layer Firestone B Base Sheet adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² Membrane Firestone SBS Glass FR, adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² Maximum Slope Class ½ʺ B ½ʺ B Unlimited B Unlimited B ½ʺ B Page 33 June 20, 2018 Continued Fully Adhered Systems – Class B UL Assembly Number Deck 18. C– 15/32 19. NC 20. C– 15/32 21. C– 15/32 Roofing System Base Sheet One layer Firestone MB Base, SBS Base, SBS Base-P sheet or SBS Premium Base Sheet, mechanically fastened Ply Sheet One layer Firestone MB Base Sheet, “SBS Base Sheet, SBS Base-P sheet or SBS Premium Base Sheet, adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² Membrane Firestone SBS FR Cap GS, SBS Premium FR or SBS Glass FR adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal² Insulation Polyisocyanurate, wood fiber, glass fiber or perlite, any thickness Base Sheet One or more layers Firestone MB Base, mechanically fastened or hot mopped Membrane Firestone SBS FR Cap GS, hot mopped Barrier Board Gypsum wallboard, ½ʺ thick min or Georgia-Pacific Gypsum LLC DensDeck, ¼ʺ thick min Insulation Polyisocyanurate, wood fiber, glass fiber or perlite, any thickness Insulation (Optional) Wood fiberboard, hot mopped Base Sheet One or more layers Firestone MB Base, mechanically fastened or hot mopped Ply Sheet One or more layers Type G1, hot mopped Membrane Firestone BS FR Cap GS, hot mopped Base Sheet One or more layers Firestone MB Base (Type G2), mechanically fastened or hot mopped Ply Sheet One or more layers Firestone Ply IV or Ply VI (Type G1) ply sheet, mechanically fastened or hot mopped Membrane One or more layers Firestone SBS Premium FR (modified bitumen), hot mopped or Firestone SBS FR Torch, heat fused Maximum Slope Class ½ʺ B 1½ʺ B 1½ʺ B ½ʺ B Page 34 June 20, 2018 Continued Fully Adhered Systems – Class B UL Assembly Number Deck 29. C– 15/32 50. C– 15/32 56. NC 58. NC 59. C– 15/32 Roofing System Base Sheet One or more layers Firestone MB Base (Type G2), mechanically fastened Cap Sheet One layer Firestone SBS Premium FR, (modified bitumen), hot mopped Insulation Firestone minimum ½ʺ RESISTA or ½ʺ ISOGARD HD Base Sheet Firestone BASEGARD SA sheet, self-adhered Membrane Firestone SBS Premium FR, SBS Glass FR, SBS Torch FR, SBS Glass FR Torch, SBS Premium FR Torch (modified bitumen), the membrane is either torched or mopped with hot asphalt to the base sheet Insulation ISO 95+ GL, RESISTA, ISOGARD HD, ISOGARD HD Composite, Wood Fiber Board, Dens Deck Prime or Securock Gypsum Fiber Board Base Ply Firestone BASEGARD SA self-adhered Cap Ply Firestone APP Premium FR, APP 180 FR Insulation ISO 95+ GL, RESISTA, ISOGARD HD, ISOGARD HD Composite, Dens Deck Base Ply BASEGARD SA self-Adhered Inter-Ply APP 170, APP 160, or APP 80 Glass Base Cap Ply APP Premium FR, APP 180 FR Insulation (Optional) ISO 95+ GL, RESISTA Barrier Board ¼", ½" or ⅝" thick Securock Glass-Mat Roof Board or Securock GypsumFiber Roof Board, Georgia-Pacific Gypsum LLC DensDeck Prime or DensDeck, cover board may be hot mopped attached with insulation adhesive or mechanically fastened Base Ply BASEGARD SA self-adhered Inter-Ply APP 170, APP 160, or APP 80 Glass Base Cap Ply APP Premium FR or APP 180 FR Maximum Slope Class ½ʺ B ¼" B 1½ʺ B 2ʺ B 2ʺ B Page 35 June 20, 2018 Fully Adhered Systems – Class C UL Assembly Number Deck 3. C– 15/32 7. NC 11. C– 15/32 13. C– 15/32 Roofing System Base Sheet OCF No. 28 Perma ply hot mopped or nailed Membrane Firestone APP 160, or Firestone APP 170 (modified bitumen), heat fused Coating Western Colloid No. 298 Emulsion, applied at 1.5-gal², Fields Products No. F900, applied at 6 gal², Gibsonite Durakote No. 151, applied at 6 gal² or Gibson-Homans No. 6192-900, applied at 5 to 7-gal² Surfacing No. 11 roofing granules applied at 50 lb² Insulation (Optional) Any UL Classified, any thickness (EPS must be covered with ½ʺ min wood fiber, glass fiber or perlite) Base Sheet Type G1, G2 or G3, or Firestone SBS Base Sheet or SBS Base P sheet, mechanically fastened or hot mopped Ply Sheet (Optional) One or more plies Firestone SBS Smooth, mechanically fastened or hot mopped Membrane Firestone SBS Cap, SBS Premium, hot mopped Insulation (Optional) Any UL Classified, any thickness Barrier Board ¼ʺ thick Georgia-Pacific Gypsum LLC DensDeck Roof Board or DensDeck DuraGuard Roof Board or DensDeck Prime Roof Board, mechanically fastened Base Sheet One ply Firestone SBS Premium Base Sheet or MB Base or Ply IV or Ply VI or SBS Base Sheet or SBS Base-P sheet fully adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal/100 ft² Membrane One ply Firestone SBS Premium FR or SBS Premium FR cap sheet fully adhered with Firestone Multi-Purpose MB Cold Adhesive at 1.5-gal/100 ft² Base Sheet One or more plies, Firestone MB Base mechanically fastened or hot mopped Ply Sheet One or more plies Firestone SBS Base or SBS Base-P sheet hot mopped Membrane One or more plies Firestone SBS Cap, hot mopped Maximum Slope Class 1ʺ C Unlimited C Unlimited C 1ʺ C Page 36 June 20, 2018 Maintenance and Repair Systems – Class A General NOTE: Karnak No. 81 modified bitumen adhesive may be used as an alternate method of attachment for the modified bitumen membranes in the following systems. An additional ply Firestone APP 160, APP 160-P, APP 170 may be used in any APP modified bitumen system. Unless otherwise indicated, insulation and base sheets may be mechanically attached, hot mopped or attached with cold application adhesive as Listed under Adhesive, Roof Construction Materials, in any system incorporating modified bitumen. Firestone MB Base or APP 80 Glass Base is an acceptable substitute and may be used in any assembly which utilizes Type G1, G2, OCF No. 28, Johns Manville No. 28 GlasBase, Bird CRS base sheet or GAF GAFGLAS base sheets. APP 180 is an acceptable alternative to APP 160 or APP 170 in all applicable systems. Firestone Ply IV or Ply VI are acceptable alternates in all systems where a Type G1 ply sheet is indicated. UL Assembly Number Deck 1. NC 2. C– 15/32 3. NC Roofing System Existing Roof System Class A, B or C (gravel may be removed) covered with: Base Sheet Type G1, G2 or G3 (granular surfaced, inverted), mechanically attached Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5- gal² or Karnak Chemical No. 97 or 169 Aluminum Coating applied at 1 gal² or No. 97 AF, applied at 1.5-gal² (optional), gravel Existing Roof System Class A covered with: Ply Sheet: OCF No. 11 or 28 base or ply sheet Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1½ gal² or Karnak Chemical No. 97, applied at 1-gal² No. 97 AF, applied at 1.5-gal² or Western Colloid No. 298 Emulsion, applied at 2-gal², with #11 Mineral Granules embedded into the wet top coat at 50 lb² Existing Roof System Class A, B or C. (Gravel may be removed) covered with: Insulation (Optional) Perlite, glass fiber, wood fiber, isocyanurate, urethane or composite, any thickness Base Sheet Type G1, G2 or G3, hot mopped or mechanically attached Membrane: Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal² or Karnak Chemical No. 97 or No. 169, applied at 1-gal² or No. 97 A”, applied at 1.5-gal² Maximum Slope Class 1ʺ A ½ʺ A 1ʺ A Page 37 June 20, 2018 Continued Maintenance and Repair Systems – Class A UL Assembly Number Deck 4. C– 15/32 9. NC 10. C– 15/32 11. NC 12. NC Roofing System Existing Roof System Class A, B or C covered with: Insulation (Optional) Perlite, glass fiber, isocyanurate, any Firestone ISO 95+ GL insulation, urethane or composite, any thickness Base Sheet One layer GAF Base sheet, Johns Manville No. 28 or Johns Manville GlasBase Base Sheet (Type G2), mechanically attached or adhered with hot roofing asphalt Membrane Firestone APP 180 FR, APP 160 or APP 170 (modified bitumen) (one or more layers), heat fused Surfacing Gravel at 400 lb² or slag at 300 lb² (the gravel may be loose laid or adhered with hot roofing asphalt) Existing Roof System Class A, B or C (gravel may be removed) covered with: Base Sheet Type G1, G2 or G3 (granular surfaced, inverted), mechanically attached Membrane Firestone APP 180 FR (modified bitumen), heat fused Existing Roof System Class A covered with: Ply Sheet OCF No. 11 or 28 base or ply sheet Membrane Firestone APP 180 FR (modified bitumen), heat fused Existing Roof System Class A, B or C. (Gravel may be removed) covered with: Insulation (Optional) Perlite, glass fiber, wood fiber, isocyanurate, urethane or composite, any thickness Base Sheet Type G1, G2 or G3, hot mopped or mechanically attached Membrane Firestone APP 180 FR (modified bitumen), heat fused Existing Roof System Class A, B or C covered with: Base Sheet (Optional) Type G1 or G2 Membrane One layer Firestone SBS Metal Flash-AL (modified bitumen), hot mopped Maximum Slope Class 1ʺ A 1ʺ A ½ʺ A 1ʺ A Unlimited A Page 38 June 20, 2018 Continued Maintenance and Repair Systems – Class A UL Assembly Number 13. 17. 18. Deck Roofing System Maximum Slope Class NC Existing Roof System Class A, B or C covered with: Base Sheet (Optional) Type G1 or G2 Membrane One layer Firestone SBS Metal Flash-AL (modified bitumen), hot mopped 1ʺ A NC Existing Roof System Class A, B or C BUR (gravel may be removed) covered with: Surfacing Two coats Industrial Aluminum Roof Coating at 1½ gal²/coat ½ʺ A NC Existing Roof System Class A, B or C BUR (gravel may be removed) covered with: Base Coat Industrial Elastomeric White Roof Coating, Industrial Elastomeric Gray Roof Coating, Industrial Elastomeric Black Roof Coating, or Industrial Elastomeric Tan Roof Coating roof coating, 1.5-gal² Surfacing Industrial Elastomeric White Roof Coating, Industrial Elastomeric Gray Roof Coating, Industrial Elastomeric Black Roof Coating, or Industrial Elastomeric Tan Roof Coating roof coating, 1.5-gal² 2½ʺ A Maintenance and Repair Systems – Class B UL Assembly Number 1. Deck Roofing System Maximum Slope Class C– 15/32 Existing Roof System Class A, B or C covered with: Insulation (Optional) Perlite, glass fiber, wood fiber, isocyanurate, Rhoflex Isocyanurate urethane or composite, any thickness Base Sheet Two layers Johns Manville No. 28 Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97, applied at 1-gal² or No. 97 AF, applied at 1.5-gal² ½ʺ B Page 39 June 20, 2018 Continued Maintenance and Repair Systems – Class B UL Assembly Number Deck 2. C– 15/32 3. C– 15/32 4. C– 15/32 5. C– 15/32 6. C– 15/32 Roofing System Existing Roof System Class B covered with: Base Sheet (Optional) Type G1 or G2 Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97 or No. 97AF, applied at 1-gal² or Western Colloid No. 298 Emulsion, applied at 2-gal², with #11 Mineral Granules applied into the wet coating at 50 lb² Existing Roof System Class A, B or C covered with: Insulation One layer min 1ʺ isocyanurate, or 11/16 glass fiber Base Sheet One layer OCF or Johns Manville No. 28 Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Firestone Aluminum Fibered Roof Coating, 1.5-gal², Karnak Chemical No. 97, applied at 1 gal² or No. 97 AF, applied at 1.5 gal² Existing Roof System Class A, B or C covered with: Insulation (Optional) Perlite, glass fiber, wood fiber, isocyanurate, urethane or composite, any thickness Base Sheet Two layers Johns Manville No. 28 Membrane Firestone APP 180 FR (modified bitumen), heat fused Existing Roof System Class B covered with: Base Sheet (Optional) Type G1 or G2 Membrane Firestone APP 180 FR (modified bitumen), heat fused Existing Roof System Class A, B or C covered with: Insulation One layer min 1ʺ isocyanurate, or 11/16 glass fiber Base Sheet One layer Johns Manville No. 28 Membrane Firestone APP 180 FR (modified bitumen), heat fused Maximum Slope Class ½ʺ B ½ʺ B ½ʺ B ½ʺ B ½ʺ B Page 40 June 20, 2018 Maintenance and Repair Systems – Class C UL Assembly Number Deck 1. C– 15/32 2. C– 15/32 3. C– 15/32 Roofing System Existing Roof System Class A, B or C covered with: Insulation (Optional) Perlite or glass fiber, ¾ - 2ʺ thick, adhesive as Listed under adhesives, Roof Deck Construction Materials Base Sheet (Optional) Type G1, G2 or G3 Membrane Firestone APP 160 or Firestone APP 170 (modified membrane), heat fused Existing Roof System Class A, B or C covered with: Insulation (Optional) Perlite or glass fiber, 2ʺ max, mechanically fastened or hot mopped Base Sheet (Optional) Type G1 or G2, mechanically fastened or hot mopped Membrane Firestone APP 160, APP 160-P or Firestone APP 170 (modified bitumen), heat fused Existing Roof System Class C covered with: Membrane Firestone APP 160 or Firestone APP 170 (modified bitumen), heat fused Surfacing Karnak Chemical No. 97, applied at 1-gal² Maximum Slope Class ¼" C ¼" C ½ʺ C Maintenance and Repair Systems – Class A, B or C UL Assembly Number 4. Deck Roofing System Maximum Slope Class NC See Note 1 Insulation Any UL Classified, any thickness, adhered with Firestone “I.S.O. Twin Pack Membrane Any UL Classified modified bitumen system, BUR system or CPE, CSM, CSPE, EPDM, NBP, PIB, PVC, TPO or TRE membrane system suitable for use with any roof insulation NOTE 1: Classification (A, B or C) and maximum incline will be the same as that of the Classified Roofing System (TGFU) currently limited to noncombustible deck See Note 1 A/B/C See Note 1 Page 41 June 20, 2018 UL Internal Fire Ratings To determine the resistance of a building to internal sources of fire, Underwriters Laboratories has conducted extensive testing and classification of wall, floor/ceiling and roof/ceiling assemblies. UL classified assemblies are rated according to the time in hours the assembly will contain a fire and still maintain structural integrity. Testing is conducted in accordance with UL Standard 263 (ASTM E-119), which is recognized by all major building codes. Roof/Ceiling Assemblies are listed in the UL Fire Resistance Directory - Vol. 1 under the prefix “P” and are classified by hourly fire rating according to the type of protection used to contain a fire: Assembly Protection Used P000 – P099 Concealed grid suspended ceiling P200 – P299 Exposed grid suspended ceiling P400 – P499 Metal lathe (plaster) ceiling P500 – P599 Gypsum board ceiling P600 – P699 Miscellaneous fireproofing P700 – P799 Spray-Applied Resistive Material P800 – P899 Spray-Applied Resistive Material P900 – P999 Unprotected concrete or composite decks It should be noted that the roof membrane forms only a small part of the total roof/ceiling assembly. For a structure to qualify for a particular “P” Assembly or Roof Deck Construction, all materials used to construct the assembly (including roof decking, ceiling materials, light fixtures, duct work and structural support members) must be UL classified and installed as described in the appropriate UL Directories. The insulations listed with each of the following “P” Assemblies are not, in most cases, the only UL accepted insulations for that assembly. Consult the UL Fire Resistance Directory - Vol. 1 for “P” Assembly information and the UL Roofing Materials and Systems Directory for Roof Deck Construction information, or call Firestone Technical Services for additional accepted insulations. UL has indicated on page 8 of the 2008 Fire Resistance Directory - Vol. 1 that "Class A, B or C roof coverings consisting of hot mopped or cold applied bituminous materials or a roof covering material classified under 'Roofing Membranes' (CHCI) may be applied directly to the concrete or wood surface of floor designs being used as roofs without a reduction of fire Resistance ratings." They further state on page 8 that "Roof insulation is to be carefully controlled relative to manufacturer, type and thickness as specified. Less than the specified thickness could result in higher temperatures on the roof covering while a greater thickness of insulation could cause earlier structural failure. Certified polystyrene insulation, with a density of 5 pcf or less, may be placed on concrete floors or structural concrete roofs without reducing the assembly rating. When Polyisocyanurate insulation is used over concrete in D 900 Series Designs, the unrestrained beam rating shall be increased by a minimum of ½ hour." Roof Deck Constructions are listed in the UL Roofing Materials and Systems Directory and are rated according to the interior flame spread of the assembly as compared to the flame spread of a typical built-up roof installed over a metal deck (UL 1256). Roof Deck Constructions may also be classified according to wind uplift performance. The fire rating of a UL Roof Deck Construction is similar to the Factory Mutual Class I internal fire (calorimeter) rating and they are deemed equivalent by the Model Building Code Agencies. Page 42 June 20, 2018 "P" Assemblies Firestone's Asphalt Roofing Systems are classified for use in the following Hourly Roof / Ceiling Designs ("P" Designs). P225, P230, P246, P259, P301, P302, P303, P508, P510, P514, P519, P560, P701, P710, P713, P717, P718, P719, P720, P722, P723, P727, P728, P729, P730, P732, P734, P735, P739, P741, P742, P745, P747, P750, P751, P753, P819, P824, P827, P828, P829, P909 & P911. Consult Fire Resistance Ratings (BXUV) in the UL Fire Resistance Directory or contact your Technical Coordinator at 800428-4511 for an acceptable insulation, thickness and additional requirements. NOTE: The accepted insulation must be used in a UL Class A, B or C rated roofing assembly. UL acceptable system (e.g. adhering EPDM to Perlite or Fiberglas) listed for "P" design may not be approved for installation and warranty by Firestone. Contact Firestone Specifications and/or your Firestone Technical Coordinator concerning acceptance. Factory Mutual General Information Factory Mutual Class 1 Approvals cover a wide range of testing of roofing products, including tests for fire resistance, corrosion resistance, fuel contribution and hail damage, Factory Mutual Approvals are known best for the uplift resistance, 1-60, 1-90, etc. afforded by an FM Approved roofing assembly: FM 1-60 assemblies have been tested to withstand 60 psf air pressure applied for a period of one minute as well as one minute at the 30 and 45 psf levels. FM 1-90 assemblies have been tested to withstand 90 psf air pressure applied for a period of one minute as well as one minute at the 30, 45, 60 and 75 psf levels. Higher uplift ratings are possible based on the deck type and its attachment, fastener density and row spacing where applicable. When Factory Mutual 1-60 or 1-90 uplift ratings are specified, additional insulation attachment and reduced perimeter and corner batten (in-seam plate or batten for Reinforced Systems) spacing will/may be required. Consult the current edition of Factory Mutual Loss Prevention Data Sheets 1-28 and 1-29 for instructions for determining the required corner and perimeter dimensions and reduced spacing and increased fastener densities. General Notations PLEASE NOTE: Not all FM-rated assemblies that use Firestone roofing products are eligible for the Firestone Red Shield, Red Shield Medallion, or Platinum Warranty. The Firestone standards, guidelines, and specifications regarding roofing system components and attachment for the warranty desired must be followed. RoofNav® assemblies are summarized in the following tables; however, an assembly search should be conducted to confirm the attachment rates and requirements set for in the approval number. In all occasions, should a discrepancy occur between this guide and RoofNav, the published information located in the approval at www.roofnav.com should be adhered and utilized. In all cases, when the project is Factory Mutual insured, please consult the FM agent assigned to the review of the project to ensure compliance. Additionally, please be aware that the following assemblies typically are in reference to the field of the roof rating and attachment. Please refer to FM Global Loss Prevention Data Sheet 1-28 and 1-29 to determine the requirements for additional fastening requirements in the perimeter and corner. The below stated assemblies may not be suitable for a Firestone Warranty. Prior to installation, contact a Firestone Representative for approval of assembly for warranty purposes. Page 43 June 20, 2018 It is acceptable to use multiple layers of FM Approved insulation, mechanically secured through all layers, and provided all the following are true: All layers are the same insulation; The total insulation thickness is not greater than the maximum FM Approved thickness of the insulation; The mechanical fastening and wind uplift rating are per the FM Approval of the top layer; and, The roof cover/insulation/fastener combination is FM Approved. Ground Roughness Definitions The descriptions below are based on information in ASCE 7. While information on this subject in the body of that standard is relatively brief, the designer must read the considerable additional information provided in the related commentary section of that document, particularly when then exposure is not obvious. Exposure Category B For Exposure Category B to be used: A. The exposing terrain should include urban and suburban areas, wooded areas, or other terrain with numerous closely spaced obstructions having the size of single-family dwellings or larger. B. Use of this exposure category should be limited to those areas for which the above terrain prevails in all directions for a distance of at least 2600' (800 m) or 20 times the height of the building or other structure, whichever is greater. C. Limited openings in this terrain, such as small parking lots, roads, road intersections, playing fields, underdeveloped lots, and tree clearings can be tolerated. For openings that exceed 600′ (180 m) in total length measured radially from the building and 165' (50 m) in width, use surface roughness exposure C. D. For buildings whose height is less than or equal to 30′ (9.1 m), the prevailing exposure B distance may be reduced to 1500' (460 m). E. In cases where the difference between exposures B and C is not obvious, use exposure C. Exposure Category C NOTE: In cases where the difference between exposure B and C is not obvious, use exposure C. For Exposure Category C to be used: A. The exposing terrain should be open with scattered obstructions having heights generally less than 30' (9 m), such as flat, open country and grasslands, and in all cases where exposures B and D do not apply. B. This also includes where surface roughness exposure B terrain is interrupted by clearings (parking lots, wide roads, road intersections, playing fields, underdeveloped lots, tree clearings, etc.) of greater than 600' (180 m) in total length measured radially from the building and exceeding 165' (50 m) in width. Exposure Category D NOTE: Some examples of D exposures include inland waterways, the Great Lakes, and coastal areas. See fig. 3.2.2.3 in FM Global LPDA 1-28 for examples of Exposure D requirements. For Exposure Category D to be used in determining the design wind pressure, all the following must be met: A. The terrain upwind of the structure must be flat, unobstructed areas or water surfaces including smooth mud flats, salt flats, and unbroken ice and is present in the upwind direction for a distance greater than approximately 5000′ (1500 m) or 20 times the building height, and B. The building must be within the greater of 600′ (180 m) or 20 times the building or structure height from the terrain (see Fig. 3.2.2.3), even if the terrain between the building and the terrain described in A. above would otherwise be considered B or C. Page 44 June 20, 2018 Field/Corner/Perimeter Definitions The following diagram is direct form the FM Global Property Lost Prevention Data Sheet 1-28. This outlines how to calculate your perimeter and corner areas based on the building size and relative conditions. ©2015 Factory Mutual Insurance Company. All rights reserved. Page 45 June 20, 2018 Perimeter and Corner Treatment of Adjoining Buildings Prescriptive Enhancement Options: Perimeter and Corner The following information has been referenced from Factory Mutual Loss Prevention Data Sheets 1-29. 2.2.10.1.1 Provide one of the following options to secure the roof perimeter and corners (Zones 2 and 3): A. Use a roof system with an FM Approval wind uplift rating that is acceptable for the field, perimeter, and corners per the Ratings Calculator of RoofNav or DS 1-28. That could entail using a system throughout the entire roof that had a wind rating adequate for the corners, or using a system that has a varied fastener spacing and multiple wind ratings that are adequate for the field, perimeter, and corner areas. B. Use the appropriate prescriptive recommendation noted in FM LPDS 1-29 Section 2.2.10.1.2. In either case, ensure any whole or partial insulation board or roof cover/base sheet width (when the roll is parallel to the building edge) that falls within the calculated perimeter or corner has the increased securement applied over the entire board or roof cover/base sheet width. 2.2.10.1.2 Use prescriptive enhancements for perimeter and corner areas (for all deck types) where roof covers are adhered to some combination of insulation or cover board if one of the following conditions applies: A. The recommended field-of-roof rating needed per DS 1-28 in any location does not exceed Class 1-75 (3.6 kPa), B. The building is in a non-hurricane-prone region (see Appendix A) and the recommended field-of-roof rating per DS 1-28 does not exceed Class 1-90 (4.3 kPa). Page 46 June 20, 2018 2.2.10.1.2.1 For either of the above conditions, increase the securement over the FM Approved field-of-roof spacing as follows: F. For assemblies using insulation fasteners, increase the number of fasteners per board by: 1. 50% minimum in the roof perimeter, but at least one fastener per 2 ft² (1 per 0.19 m²). It is not necessary to install fasteners closer than one per 1 ft² (1 per 0.09 m²). 2. One fastener per 1 ft² (1 per 0.09 m²) in corner areas. 3. Round up to the next whole number of fasteners, if necessary G. For components adhered with adhesives applied in ribbons, spots, etc., reduce the spacing between ribbons or spots over the FM Approved spacing for the given wind rating as noted below (round down to a dimension that is practical with respect to board sizes, applicators, etc.): 1. In the roof perimeter, not more than 60% of the field-of-roof spacing between rows, or area Roof Deck Securement and Above-Deck Roof Components 1-29 FM Global Property Loss Prevention Data Sheets Page 21 ©2016 Factory Mutual Insurance Company. All rights reserved. 2. In the roof corners, not more than 40% of the field-of-roof spacing between rows, or area NOTE: If the FM Approval wind rating already meets the higher criteria for the perimeter or corner area, no further reduction is needed in those areas. Prescriptive Enhancement Examples. Actual fastening rates may vary. Field Perimeters Corners Field Perimeters Corners 8 16 32 16 24 32 10 15 32 18 28 32 12 18 32 20 30 32 15 24 32 Base Sheet Attachment The attachment patterns listed below are recommended for base sheet securement when installed below Firestone Building Products approved systems. Other factors may require additional/different attachment rates. Peak Gust Wind Speed Coverage 55 mph 72-80 mph 90 mph Regional Wind Speed Lap Up to 110 mph Field/Perimeter 110-120 mph Field/Perimeter Corner Lap 35ʺ Rows, 9ʺ o.c. 35ʺ Rows, 8ʺ o.c. 2 Rows, 12ʺ o.c. Staggered 18ʺ o.c. spacing 2 Rows, 12ʺ o.c. Staggered 17ʺ o.c. spacing 3 Rows, Equally Spaced, 16ʺ o.c. spacing 3 Rows, Equally Spaced, 15ʺ o.c. spacing 35ʺ Rows, 9ʺ o.c. 35ʺ Rows, 8ʺ o.c. 2 Rows, 12ʺ o.c. Staggered, 16ʺ o.c. spacing 2 Rows, 12ʺ o.c. Staggered, 14ʺ o.c. spacing 3 Rows, Equally Spaced, 14ʺ o.c. spacing 3 Rows, Equally Spaced, 12ʺ o.c. spacing Corner 35ʺ Rows, 7ʺ o.c. 2 Rows, 12ʺ o.c. Staggered 16ʺ o.c. spacing 3 Rows, Equally Spaced, 14ʺ o.c. spacing 35ʺ Rows, 7ʺ o.c. 2 Rows, 12ʺ o.c. Staggered, 12ʺ o.c. spacing 3 Rows, Equally Spaced, 10ʺ o.c. spacing NOTE: Wind speeds over 80 mph require the use of 60-80 mil membranes. FM Insured or other code/testing agencies may require different/additional attachment methods/rate. Firestone 1.7ʺ LWC Base Ply Fasteners – Pull out value minimum 40 lb/fastener. Minimum 2ʺ thick LWC required. For Cellular Light Weight Concrete decks that are properly prepared and dry, Firestone does not require a vapor retarder, however one is recommended, if insulation is installed with the system. Page 47 June 20, 2018 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift 60 IF: 1 EF: A Slope: 1" 60 IF: 1 EF: A Slope: 1" Deck Type Vapor Barrier/ Thermal Barrier Steel: 22-16 ga 33 ksi 72" span None Cover Board: ¼" min., 4' x 8' boards DensDeck DensDeck Prime Securock Insulation: 1½"-12" ISO 95+ GL or 1" min., Structodek HD Steel: 22-16 ga 33 ksi 72" span Cover Board/ Insulation None Cover Board: ¼" min., 4' x 8' boards DensDeck DensDeck Prime Securock Insulation: 1½"-12", ISO 95+ GL or 1" min., Structodek HD Cover Board/ Insulation Attachment Cover Board: Firestone HD Fasteners, 16 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 16 per 4' x 8' board Insulation: Loose Laid Vapor Barrier (Optional): 90 IF: 1 EF: A Slope: 1" Steel: 22-16 ga 33 ksi 72" span 4-6 mil poly V-Force (SA) ¼" min. DensDeck Cover Board: ¾" min. Perlite Insulation: 2.2"-12", ISO 95+ GL SA Primer may be required. Cover Board: Firestone HD Fasteners, 16 per 4' x 8' board Insulation: Loose Laid Vapor Barrier (Optional): 90 IF: 1 EF: A Slope: 1" Steel: 22-16 ga 33 ksi 72" span 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board: ¼" min., 4' x 8' boards DensDeck Securock Insulation: 2.2"-12", ISO 95+ GL Cover Board: Firestone HD Fasteners, 16 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Premium Base Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: SBS Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Premium Base Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Premium Base Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt RoofNav Number 17794648585-0 17794648979-0 6200448585-0 169823169787-0 Page 48 June 20, 2018 Continued SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift Deck Type Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Vapor Barrier : 90 IF: 1 EF: A Slope: 1" Steel: 22-16 ga 33 ksi 72" span V-Force (SA) ¼" min. DensDeck Securock 4' x 8' boards Min. 8 HD fasteners per board. Vapor Barrier (Optional): 105 IF: 1 EF: A Slope: ½" Steel (WR): 22-18 ga 33 ksi 72" span 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Vapor Barrier (Optional): 135 IF: 1 EF: A Slope: ½" Steel (WR): 22-18 ga 33 ksi 72" span 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Vapor Barrier (Optional): 150 IF: 1 EF: A Slope: ½" Steel (WR): 22-18 ga 33 ksi 72" span 4-6 mil poly OR V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board: ½" min., 4' x 8' boards DensDeck Securock Insulation: 1½"-4", ISO 95+ GL Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board/ Insulation Attachment Cover Board: 4′x4′ boards Adhered with: ISO Stick 12” o.c. beads Insulation: 4′x4′ boards Adhered with: ISO Spray R ISO Twin Pack ISO Stick 12” o.c. beads Cover Board: Firestone HD Fasteners, 18 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 18 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 18 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: SBS Base SBS Premium Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt RoofNav Number 29879748625-0 394249394202-0 395174394202-0 395175394202-0 Page 49 June 20, 2018 Continued SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift 165 IF: 1 EF: A Slope: 1" 180 IF: 1 EF: A Slope: 1" 195 IF: 1 EF: A Slope: ½" 315 IF: 1 EF: A Slope: ½" Deck Type Steel (WR): 22-18 ga 33 ksi 72" span Steel (WR): 22-18 ga 80 ksi 72" span Vapor Barrier/ Thermal Barrier Vapor Barrier (Optional): 4-6 mil poly Thermal Barrier (Optional): ¼" min. DensDeck Vapor Barrier (Optional): 4-6 mil poly Thermal Barrier (Optional): ¼" min. DensDeck Vapor Barrier (Optional): Steel (WR): 22-18 ga 80 ksi 72" span V-Force (SA) ¼" min. DensDeck SA Primer may be required. Steel (WR): 18 ga,33 ksi 68" span 20 ga,58 ksi 68" span 22 ga,33 ksi 52" span 22-18 ga 80 ksi 71" span 20-18 ga 80 ksi 72" span Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board/ Insulation Cover Board: ½" min., 4' x 8' boards Securock Insulation: 1.½"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards Securock Insulation: 1.5"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime or Securock Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2.2"-12", ISO 95+ GL or RESISTA Cover Board/ Insulation Attachment Cover Board: Firestone HD Fasteners, 22 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 22 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 24 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 32 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt Cap: Hot Asphalt Base: Hot Asphalt RoofNav Number 353705345379-0 353707345379-0 390822389938-0 395177394203-0 Page 50 June 20, 2018 Continued SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift 315 IF: 1 EF: A Slope: ½" Hail: SH Deck Type Steel (WR): 18 ga,33 ksi 68" span 20 ga,58 ksi 68" span 22 ga,33 ksi 52" span 22-18 ga 80 ksi 71" span 20-18 ga 80 ksi 72" span Vapor Barrier/ Thermal Barrier Vapor Barrier: V-Force(SA) Primer Thermal Barrier: ½" min., 4' x 8' boards, DensDeck Cover Board/ Insulation Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2.2"-24", ISO 95+ GL or RESISTA Cover Board/ Insulation Attachment Cover Board: Firestone HD Fasteners, 32 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Cap: Hot Asphalt Base: Hot Asphalt Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base RoofNav Number 419044394203-0 SBS – 3 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift Deck Type Vapor Barrier (Optional): 90 IF: 1 EF: A Slope: ½" Hail: SH Vapor Barrier/ Thermal Barrier Steel: 22-16 ga 33 ksi 72" span 4-6 mil poly OR V-Force (SA) ¼" min. DensDeck SA Primer may be required. Vapor Barrier (Optional): 105 IF: 1 EF: A Slope: ½" Steel (WR): 22-16 ga 33 ksi 72" span 4-6 mil poly OR V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board/ Insulation Cover Board: ¼" min., 4' x 8' boards DensDeck or DensDeck Prime Insulation: 1.5"-12", ISO 95+ GL or 1" min. Structodek HD Cover Board: ¼" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board/ Insulation Attachment Cover Board: Firestone HD Fasteners, 18 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 18 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Inner Ply: (1) Type IV or VI SBS Base SBS Smooth Base Sheet: MB Base SBS Base SBS Premium Base Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Inner Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth RoofNav Number Cap: Hot Asphalt Inner Ply: Hot Asphalt 17740848582-0 Base: Hot Asphalt Cap: Hot Asphalt Inner Ply: Hot Asphalt 394249394006-0 Base: Hot Asphalt Page 51 June 20, 2018 Continued SBS – 3 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift Deck Type Vapor Barrier/ Thermal Barrier Vapor Barrier (Optional): 135 IF: 1 EF: A Slope: ½" Steel (WR): 22-18 ga 33 ksi 72" span 4-6 mil poly OR V-Force (SA) ¼" min. DensDeck SA Primer may be required. Vapor Barrier (Optional): 150 IF: 1 EF: A Slope: ½" Steel (WR): 22-18 ga 33 ksi 72" span 4-6 mil poly OR V-Force (SA) ¼" min. DensDeck SA Primer may be required. 195 IF: 1 EF: A Slope: ½" Vapor Barrier (Optional): Steel (WR): 22-18 ga 80 ksi 72" span V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board/ Insulation Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime OR Securock Insulation: 2"-12", ISO 95+ GL or RESISTA Cover Board/ Insulation Attachment Cover Board: Firestone HD Fasteners, 18 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 20 per 4' x 8' board Insulation: Loose Laid Cover Board: Firestone HD Fasteners, 24 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Inner Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Inner Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Inner Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth RoofNav Number Cap: Hot Asphalt Inner Ply: Hot Asphalt 395174394006-0 Base: Hot Asphalt Cap: Hot Asphalt Inner Ply: Hot Asphalt 395175394006-0 Base: Hot Asphalt Hot Asphalt Inner Ply: Hot Asphalt 390822389940-0 Base: Hot Asphalt Page 52 June 20, 2018 Continued SBS – 3 Ply – Hot Asphalt – Cover Board/Insulation Attached – Steel Deck Uplift Deck Type Steel (WR): 18 ga,33 ksi 68" span 20 ga,58 ksi 68" span 315 IF: 1 EF: A Slope: ½" 22 ga,33 ksi 52" span 22-18 ga 80 ksi 71" span 20-18 ga 80 ksi 72" span Vapor Barrier/ Thermal Barrier Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board/ Insulation Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2.2"-12", ISO 95+ GL or RESISTA Cover Board/ Insulation Attachment Cover Board: Firestone HD Fasteners, 32 per 4' x 8' board Insulation: Loose Laid Membrane Attachment Membrane Options Cap Ply: SBS FR SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Inner Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base RoofNav Number Cap Ply: Hot Asphalt Inner Ply: Hot Asphalt 395177394201-0 Base: Hot Asphalt SBS – 2 Ply – Hot Asphalt – Cover Board - Adhered/Insulation - Attached – Steel Deck Uplift Deck Type 90 Steel: IF: 1 EF: A Slope: 1" 22 ga 33 ksi 72" span 90 IF: NC EF: A Slope: 1" Structural Concrete: 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Thermal Barrier (Optional): ⅝" min., 4' x 8' boards DensDeck DensDeck Prime Securock Thermal Barrier (Optional): ⅝" min., 4' x 8' boards DensDeck DensDeck Prime Securock Vapor Barrier – Against Deck (Optional): V-Force (SA), primer may be required SBS Torch Cover Board/ Insulation Cover Board: ¼" min., 4' x 8' boards DensDeck DensDeck Prime Securock Insulation: 2.2"-12", min. 4' x 4' boards ISO 95+ GL Cover Board: ¼" min., 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 1.5"-4", min. 4' x 4' boards ISO 95+ GL Cover Board/ Insulation Attachment Cover Board: Hot Asphalt Insulation: Firestone HD Fasteners, 8 per 4' x 8' board Cover Board: Hot Asphalt Insulation: Firestone HD Fasteners, 10 per 4' x 8' board Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: SBS Base SBS Premium Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: SBS Base SBS Premium Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 6205848625-0 6205948625-0 Page 53 June 20, 2018 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Adhered – Thermal Attached – Concrete Deck Uplift 90 IF: NC EF: A Slope: 1" Deck Type Structural Concrete: 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Vapor Barrier: V-Force (SA), Permeable Primer Thermal Barrier: ¼" min., 4' x 8' boards DensDeck DensDeck Prime Securock Secured with min. 8 fasteners per board Concrete Drive Firestone HD Cover Board/ Insulation Attachment Cover Board/ Insulation Cover Board: ¼" min., 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 1.5"-4", min. 4' x 4' boards ISO 95+ GL Cover Board: 12" o.c. bead spacing ISO Spray R ISO Twin Pack ISO Stick Insulation: 12" o.c. bead spacing ISO Spray R ISO Twin Pack ISO Stick Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: SBS Base SBS Premium Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 29877648625-0 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Adhered – Concrete Deck Uplift Deck Type Vapor Barrier/ Thermal Barrier Cover Board/ Insulation None Cover Board: ¼" min., 4' x 4' boards DensDeck DensDeck Prime Securock Insulation (Top Layer): ½"-4ʺ Tapered. 4' x 4' boards ISO 95+ GL Insulation (Bottom Layer): 1.5"-36", min. 4' x 4' boards ISO 95+ GL 240 IF: NC EF: A Slope: 1" 525 IF: NC EF: A Slope: 1" Structural Concrete: 2,500 psi min. 2" thick min. Structural Concrete: 2,500 psi min. 2" thick min. Primer (Optional): Asphaltic Cover Board: ¼" min., 4' x 4' boards DensDeck Securock None Insulation: 1.5"-36ʺ, 4′x4′ boards ISO 95+ GL Cover Board/ Insulation Attachment Cover Board: Hot Asphalt Insulation (Top): Hot Asphalt Insulation (Bottom): Hot Asphalt Cover Board: Hot Asphalt Insulation: Hot Asphalt Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Smooth Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 2835782835750 3845063845000 Page 54 June 20, 2018 Continued SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Adhered – Concrete Deck Uplift 525 IF: NC EF: C Slope: 5" Deck Type Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Structural Concrete: 2,500 psi min. 2" thick min. Cover Board: ¼" min., 4' x 4' boards DensDeck Prime None Primer (Optional): Asphaltic Insulation: 1.5"-36", min. 4' x 4' boards ISO 95+ GL Cover Board/ Insulation Attachment Cover Board: Hot Asphalt Insulation: Hot Asphalt Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Smooth Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 295863295809-0 SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Concrete Deck Uplift 105 IF: NC EF: A Slope: ½" 135 IF: NC EF: A Slope: ½” 150 IF: NC EF: A Slope: ½” Deck Type Structural Concrete: 2,500 psi min. 2" thick min. Structural Concrete: 2,500 psi min. 2" thick min. Structural Concrete: 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Vapor Barrier – (Optional): V-Force (SA) direct to deck, primer or BaseGard SA, Primer, ¼" DensDeck Vapor Barrier – (Optional): 4 or 6-mil. poly or V-Force (SA) direct to deck, primer or BaseGard SA, Primer, ¼" DensDeck Vapor Barrier (Optional): 4 or 6-mil. poly or V-Force (SA) direct to deck, primer or BaseGard SA, Primer, ¼" DensDeck Cover Board/ Insulation Cover Board: ¼" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 8' boards ISO 95+ GL/RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 8' boards ISO 95+ GL/RESISTA Cover Board: ¼" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 8' boards ISO 95+ GL/RESISTA Cover Board/ Insulation Attachment Cover Board: 18 HD fasteners per board Insulation: Common Fastened Cover Board: 18 HD fasteners per board Insulation: Common Fastened Cover Board: 20 HD fasteners per board Insulation: Common Fastened Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 395178394203-0 395181394203-0 395184394203-0 Page 55 June 20, 2018 Continued SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation Attached – Concrete Deck Uplift 180 IF: NC EF: A Slope: ½" 315 IF: NC EF: A Slope: ½" Deck Type Structural Concrete: 2,500 psi min. 2" thick min. Structural Concrete: 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Vapor Barrier (Optional): V-Force (SA) direct to deck, primer Vapor Barrier (Optional): 4 or 6-mil. poly or V-Force (SA) direct to deck, primer or BaseGard SA, Primer, ¼" DensDeck Cover Board/ Insulation Cover Board: ½" min., 4' x 8' boards Securock Insulation: 1.5"-12", min. 4' x 8' boards ISO 95+ GL/RESISTA Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2.2"-12", min. 4' x 8' boards ISO 95+ GL/RESISTA Cover Board/ Insulation Attachment Cover Board: 22 Concrete Drive or HD fasteners per board Insulation: Common Fastened Cover Board: 32 HD fasteners per board Insulation: Common Fastened Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 390818389938-0 395190394203-0 SBS/Ply – 3 Ply – Hot Asphalt – Cover Board/Insulation – Concrete Deck Uplift 90 IF: NC EF: A Slope: 1" Deck Type Structural Concrete: 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Vapor Barrier (Optional): V-Force (SA) direct to deck, primer or SBS Torch Cover Board/ Insulation Cover Board: ¼", 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 2"-4", 4' x 8' boards ISO 95+ GL Cover Board/ Insulation Attachment Cover Board: Hot Asphalt Insulation: 8 HD Fasteners per board Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Ply Sheet: Type IV, Type VI Base Sheet: SBS Base SBS Premium Base Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Membrane Attachment RoofNav Number Cap Ply: Hot Asphalt Ply: Hot Asphalt 6206048622-0 Base Ply: Hot Asphalt Page 56 June 20, 2018 Continued SBS/Ply – 3 Ply – Hot Asphalt – Cover Board/Insulation – Concrete Deck Deck Type Uplift Vapor Barrier/ Thermal Barrier Structural Concrete: 90 IF: NC EF: A Slope: 1" 240 2,500 psi min. 2" thick min. Cover Board: ½” min., 4' x 4' boards Structodek HD Insulation: 1.5"-36", 4' x 4' boards ISO 95+ GL Cover Board: ¼" min., 4' x 4' boards Structodek HD Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: 1" 2,500 psi min. 2" thick min. Cover Board: Hot Asphalt Insulation: Hot Asphalt Cover Board: ISO Fix II ISO Spray R ISSO Twin Pack Hot Asphalt None Insulation: 2"-36", 4' x 4' boards ISO 95+ GL Structural Concrete: 525 Cover Board/ Insulation Attachment None Primer (Optional): Asphaltic IF: NC EF: A Slope: 1.5" Cover Board/ Insulation None Primer (Optional): Asphaltic Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Structodek HD Insulation: 1.5"-36", 4' x 4' boards ISO 95+ GL Insulation: ISO Fix II ISO Spray R ISSO Twin Pack Hot Asphalt Cover Board: Hot Asphalt Insulation: Hot Asphalt Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Ply Sheet: MB Base Type IV, Type VI Base Sheet: MB Base Type IV, Type VI Cap Ply: SBS Smooth Ply Sheet: Type IV, Type VI SBS Base SBS Smooth Base Sheet: MB Base SBS Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Ply Sheet: Type IV, Type VI SBS Base SBS Smooth Base Sheet: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Smooth Membrane Attachment RoofNav Number Cap Ply: Hot Asphalt Ply: Hot Asphalt 384524384483-0 Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Ply: Hot Asphalt 19164948583-0 Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Ply: Hot Asphalt 296000295831-0 Base Ply: Hot Asphalt SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation – LWIC Over Concrete Deck Uplift/Deck PSF: 180 IF: NC EF: A Slope: 1" Hail: SH Structural Concrete: 2,500 psi min. 2" thick min. Cover Board/Insulation Cover Board: ¼" min., 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 1.5"-12", 4' x 4' boards ISO 95+ GL Lightweight Concrete: Range II Elastizell Min. 20" thick Cover Board/ Insulation Attachment Cover Board: 12" o.c. beads ISO Stick Insulation: 12" o.c. beads ISO Stick Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: MB Base, SBS Base SBS Premium Base Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 181799-4858550941 Page 57 June 20, 2018 Continued SBS – 2 Ply – Hot Asphalt – Cover Board/Insulation – LWIC Over Concrete Deck Uplift/Deck PSF: 180 IF: NC EF: A Slope: 1" Hail: SH Structural Concrete: 2,500 psi min. 2" thick min. PSF: 315 IF: NC EF: A Slope: 1" Hail: SH Structural Concrete: 2,500 psi min. 2" thick min. PSF: 315 IF: NC EF: A Slope: 1" Hail: SH Structural Concrete: 2,500 psi min. 2" thick min. PSF: 315 IF: NC EF: A Slope: 1" Hail: SH Structural Concrete: 2,500 psi min. 2" thick min. Cover Board/Insulation Cover Board: ¼" min., 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: ½"-12", 4' x 4' boards ISO 95+ GL Lightweight Concrete: Range II Elastizell 1"-12" EPS Range II Elastizell Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Securock Insulation: 1"-12", 4' x 4' boards ISO 95+ GL Lightweight Concrete: Celcore PVA Curing Compound Celcore MF 1"-12" EPS Celcore MF Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Securock Insulation (Top): ½"-4", 4' x 4' boards Tapered ISO 95+ GL Tapered RESISTA Insulation (Bottom): 1"-8", 4' x 4' boards ISO 95+ GL Lightweight Concrete: Celcore PVA Curing Compound Celcore MF 1"-12" EPS Celcore MF Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Securock Insulation: 1"-12", 4' x 4' boards ISO 95+ GL/RESISTA Lightweight Concrete: Celcore PVA Curing Compound Celcore MF 1"-12" EPS Celcore MF Cover Board/ Insulation Attachment Cover Board: 12" o.c. beads ISO Stick Insulation: 12" o.c. beads ISO Stick Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation: ISO Twin Pack Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation (Top): ISO Twin Pack Insulation (Bottom): ISO Twin Pack Cover Board: 12" o.c. beads ISO Stick Insulation: ISO Stick Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: MB Base, SBS Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: MB Base SBS Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 181799-4858550936 339987-283575339279 339991-283575339279 340054-283575339279 Page 58 June 20, 2018 SBS – 2 Ply – Nailed Base Sheet – LWIC – Steel Deck Uplift Deck Type Vapor Barrier/ Thermal Barrier Coating/Surfacing: Celcore PVA Curing Compound 90 Steel (WR): IF: 1 EF: A Slope: 1" None 22 ga 72" span Cover Board/ Insulation Attachment Cover Board/ Insulation Lightweight Insulating Concrete: Celcore Cellular Concrete (min. 200 psi) Base Sheet: Channel Venting MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Fasteners: LWC Base Ply Fasteners EPS, 1"-12" Celcore Cellular Concrete: (min. 200 psi) Coating/Surfacing: Celcore PVA Curing Compound 90 Steel (WR): IF: 1 EF: A Slope: 1" 22 ga 72" span None Lightweight Insulating Concrete: Celcore Cellular Concrete (min. 340 psi) EPS, 1"-12" Base Sheet: Channel Venting MB Base SBS Base SBS Poly Torch Base SBS Poly Base SBS Premium Base SBS Smooth SBS Torch Base Celcore Cellular Concrete: (min. 340 psi) Fasteners: Two Piece Impact Nails Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base Type IV, Type VI SBS Poly Base SBS Premium Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UltraWhite SBS Glass FR SBS Glass FR UltraWhite SBS Premium FR SBS Premium FR UltraWhite Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt RoofNav Number 622404903250912 Cap Ply: Hot Asphalt Base Ply: LiquiGard Membrane Adhesive 338359338337326460 SBS – 2 Ply – Nailed Base Sheet – LWIC – Form Deck Uplift/Deck Cover Board/ Insulation PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Form Deck Span: max 72" Lightweight Insulating Concrete: Mearlcrete EPS (optional), 1"12" Mearlcrete Cover Board/ Insulation Attachment Base Sheet: Channel Venting MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Fasteners: Two Piece Impact nail Seam: 35.4" o.c. at 7" o.c. Filed: 2 rows, staggered at 11.75" o.c. Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: SBS Base SBS Poly Base SBS Premium Base SBS Smooth Membrane Attachment Cap Ply: MB Cold Base Ply: MB Cold RoofNav Number 325469295652325250 Page 59 June 20, 2018 Continued SBS – 2 Ply – Nailed Base Sheet – LWIC – Form Deck Uplift/Deck PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Form Deck Span: max 72" Cover Board/ Insulation Base Sheet: Coating/Surfacing: Channel Venting Celcore PVA Curing MB Base Compound SBS Base Lightweight Insulating SBS Poly Base Concrete: SBS Premium Base Celcore MF Cellular SBS Smooth Concrete (min. 350 psi) Fasteners: EPS, 1"-12" 1.7" LWC Base Ply Fasteners Celcore MF Cellular Seam: 35.4" o.c. at 9" o.c. Concrete Filed: 2 rows, staggered at (min. 350 psi) 12" o.c. PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Form Deck Span: max 72" PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Form Deck Span: max 72" PSF: 120 IF: 1 EF: A Slope: 1" Hail: SH Form Deck Span: max 72" Cover Board/ Insulation Attachment Lightweight Insulating Concrete: Mearlcrete EPS (optional), 1"-12" Mearlcrete Coating/Surfacing: Celcore PVA Curing Compound Lightweight Insulating Concrete: Celcore MF Cellular Concrete (min. 350 psi) EPS, 1"-12" Celcore MF Cellular Concrete (min. 350 psi) Coating/Surfacing: Celcore PVA Curing Compound Lightweight Insulating Concrete: Celcore Cellular Concrete (min. 200 psi) EPS, 1"-12" Celcore MF Cellular Concrete (min. 200 psi) Base Sheet: Channel Venting MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Fasteners: Two Piece Impact nail Seam: 35.4" o.c. at 7" o.c. Filed: 2 rows, staggered at 11.75" o.c. Base Sheet: Channel Venting MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Fasteners: 1.7" LWC Base Ply Fasteners Seam: 35.4" o.c. at 9" o.c. Filed: 2 rows, staggered at 12" o.c. Base Sheet: Channel Venting MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Fasteners: 1.7" LWC Base Ply Fasteners Seam: 35.4" o.c. at 9" o.c. Filed: 2 rows, staggered at 12" o.c. Membrane Options Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Sheet: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base Sheet: SBS Glass Torch Base SBS Poly Torch Base SBS Smooth Torch Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap Ply: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base Sheet: SBS Glass Torch Base SBS Poly Torch Base SBS Torch Base Membrane Attachment Cap Ply: Hot Asphalt Base Ply: Hot Asphalt Cap Ply: Torched Base Ply: Torched Cap Ply: Torched Base Ply: Torched Cap Ply: Torched Base Ply: Torched RoofNav Number 382860382810143350 325495353927325250 382815382813143350 29159120037750912 Page 60 June 20, 2018 Continued SBS – 2 Ply – Nailed Base Sheet – LWIC – Form Deck Uplift/Deck PSF: 120 IF: 1 EF: A Slope: 1.5" Hail: SH Form Deck Span: max 72" Cover Board/ Insulation Cover Board/ Insulation Attachment Coating/Surfacing: Celcore PVA Curing Compound Lightweight Insulating Concrete: Celcore Cellular Concrete (min. 200 psi) EPS, 1"-12" Celcore MF Cellular Concrete (min. 200 psi) Base Sheet: Channel Venting MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Membrane Options Fasteners: 1.7" LWC Base Ply Fasteners Seam: 35.4" o.c. at 9" o.c. Filed: 2 rows, staggered at 12" o.c. Coating/Surfacing: Hot Asphalt/Gravel Cap Ply: SBS Premium Torch SBS Premium Torch UW SBS Smooth Torch SBS Torch SBS Torch UW Base Sheet: SBS Glass Torch Base SBS Poly Torch Base SBS Smooth Torch SBS Torch Base Membrane Attachment Cap Ply: Torched RoofNav Number 29159225837350912 Base Ply: Torched SBS – Cap Torched – Base Sheet – Cover Board/Insulation Attached – Steel Deck Uplift/Deck Cover Board/ Insulation Cover Board/ Insulation Attachment 90 IF: 1 EF: A Slope: 1" 135 IF: 1 EF: A Slope: 1" 165 IF: 1 EF: A Slope: 1" Steel: 22-16 ga 33 ksi 72" span Steel (WR): 22-18 ga 33 ksi 72" span Steel (WR): 22-18 ga 33 ksi 72" span Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Pre-Securement Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Pre-Securement Cover Board: ½" min., 4′x8′ boards DensDeck DensDeck Prime Securock Pre-Securement Insulation: 1½"-12", min. 4′x4′ boards ISO 95+ GL Common Fastened Membrane Options Cap Ply: SBS FR Torch SBS FR Torch UltraWhite SBS Glass FR Torch SBS Glass FR Torch UltraWhite SBS Premium FR Torch SBS Premium FR Torch UltraWhite Base Sheet: Channel Venting Base MB Base SBS Base Cap Ply: SBS FR Torch SBS FR Torch UltraWhite SBS Glass FR Torch SBS Glass FR Torch UltraWhite SBS Premium FR Torch SBS Premium FR Torch UltraWhite Base Sheet: SBS Poly Torch Base Cap Ply: SBS FR Torch SBS FR Torch UltraWhite SBS Glass FR Torch SBS Glass FR Torch UltraWhite SBS Premium FR Torch SBS Premium FR Torch UltraWhite Base Sheet: SBS Glass Torch Base SBS Poly Torch Base SBS Smooth Torch Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Membrane Attachment RoofNav Number Cap: Torched Base Sheet: HD Fasteners Laps: 36.4" Rows, 12" o.c. 4749750456-0 Field Rows: 2 Rows at 18" o.c. Staggered Cap: Torched Base: Torched & HD Fasteners w/ Batten Strip 35.5" Rows, 12" o.c. 5909550456-0 Cap: Torched Base: Torched & HD Plus Fasteners w/ Metal Batten Strip 36" Rows, 6" o.c. 329151155408-0 Page 61 June 20, 2018 Continued SBS – Cap Torched – Base Sheet – Cover Board/Insulation Attached – Steel Deck Uplift/Deck 315 IF: 1 EF: A Slope: 1" Cover Board/ Insulation Steel (WR): 18 ga, 33 ksi 68" span 20 ga, 33 ksi 58" span 22 ga, 33 ksi 52" span 22-18 ga, 80 ksi 72" span 22 ga, 80 ksi 71" span Cover Board/ Insulation Attachment Cover Board: ½" min., 4' x 8' boards DensDeck DensDeck Prime Securock Pre-Securement Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL Common Fastened Membrane Options Cap Ply: SBS FR Torch SBS FR Torch UltraWhite SBS Glass FR Torch SBS Glass FR Torch UltraWhite SBS Premium FR Torch SBS Premium FR Torch UltraWhite Base Sheet: SBS Glass Torch Base SBS Poly Torch Base SBS Smooth Torch Optional: Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Membrane Attachment RoofNav Number Cap: Torched Base: Torched & HD Plus Fasteners w/ Metal Batten 36" Rows, 6" o.c. 155415155408-0 SBS – Cap Torched – Base Attached – Cover Board/Insulation Attached – Concrete Deck Uplift Deck Type 90 Structural Concrete: IF: NC EF: A Slope: 1" 2,500 psi min. 2" thick min. Cover Board/ Insulation Insulation: 1½"-12ʺ, min. 4' x 4' boards ISO 95+ GL Vapor Retarder (Optional): V-Force Membrane Options Membrane Attachment RoofNav Number Cap Ply: SBS FR Torch SBS FR Torch UltraWhite SBS Glass FR Torch SBS Glass FR Torch UltraWhite SBS Premium FR Torch SBS Premium FR Torch UltraWhite Base Sheet: SBS Glass Torch Base SBS Poly Torch Base SBS Smooth Torch Cap: Torched Base: Torched & HD Plus Fasteners w/ Metal Batten Strip Lap: 36.4" Rows, 12" o.c. Field: 2 Rows, 18" o.c. Staggered Channel Venting Base MB Base, SBS Base 278401-50456-0 SBS – Cap and Base Torched – Cover Board/Insulation – Steel Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 90 22-18 ga 33 ksi 72" span Cover Board: ½" min., 4' x 8' boards DensDeck None IF: 1 EF: A Slope: 1" PSF: 90 22-16 ga 33 ksi 72" span IF: 1 EF: A Slope: ½" Hail: SH Cover Board/ Insulation Thermal (Optional): ¼" min., 4′x8′ boards DensDeck DensDeck Prime Securock Cover Board/ Insulation Attachment Cover Board: 8 HD Fasteners per board Insulation: 1½"-12", 4' x 4' min. Insulation: Common Fastened Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock Insulation (Top): ½"-9.8", 4' x 4' min. Insulation (Bottom): 2.2"-4", 4′x4′ min. Max Insulation 12" Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation (Top): 12" o.c. beads ISO Twin Pack Insulation (Bottom): 8 HD Fasteners per board Membrane Options Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Base: SBS Glass Torch Base SBS Poly Torch Base SBS Torch Base Cap: SBS Premium Torch SBS Premium Torch UW SBS Smooth Torch SBS Torch SBS Torch UW Base: SBS Glass Torch Base SBS Torch Base Membrane Attachment Cap: Torched Base: Torched Cap: Torched Base: Torched RoofNav Number 388275200377-0 385473155397-0 Page 62 June 20, 2018 Continued SBS – Cap and Base Torched – Cover Board/Insulation – Steel Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 90 22-16 ga 33 ksi 72" span IF: 1 EF: A Slope: 1" Hail: SH Thermal (Optional): ¼" min., 4' x 8' boards DensDeck DensDeck Prime Securock Cover Board/ Insulation Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock Insulation: 2.2"-2", 4' x 8' ISO 95+ GL/ RESISTA Cover Board/ Insulation Attachment Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation (Bottom): 8 HD Fasteners per board Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: SBS Glass Torch Base SBS Torch Base Membrane Attachment Cap: Torched Base: Torched RoofNav Number 385484155400-0 SBS – Cap and Base Torched – Cover Board/Insulation Attached – Concrete Deck Uplift/Deck Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 90 Structural Concrete: 2,500 psi min. 2" thick min. Vapor Retarder (Optional): V-Force (SA) Primer IF: NC EF: A Slope: ½" Cover Board: ¼" min., 4' x 8' boards DensDeck Securock Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL Cover Board: 16 HD Fasteners/Plates Insulation: Common Fastened PSF: 105 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: ½" Vapor Retarder (Optional): 4-6 mil. Poly V-Force (SA) Primer BaseGard SA Primer DensDeck Cover Board: ¼" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 4' boards ISO 95+ GL/RESISTA Cover Board: 18 HD Fasteners/Plates Insulation: Common Fastened Membrane Options Cap: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Base: SBS Glass Torch Base SBS Poly Torch Base SBS Premium Poly Base SBS Smooth Cap: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Base: SBS Glass Torch Base SBS Poly Torch Base SBS Premium Poly Base Membrane Attachment Cap: Torched Base: Torched Cap: Torched Base: Torched RoofNav Number 390815389953-0 395159394200-0 Page 63 June 20, 2018 Continued SBS – Cap and Base Torched – Cover Board/Insulation Attached – Concrete Deck Uplift/Deck Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 135 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: ½" Vapor Retarder (Optional): 4-6 mil. Poly V-Force (SA) Primer BaseGard SA Primer DensDeck Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board: 18 HD Fasteners/Plates Insulation: Common Fastened PSF: 195 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: ½" Vapor Retarder (Optional): 4-6 mil. Poly V-Force (SA) Primer BaseGard SA Primer DensDeck Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board: 24 HD Fasteners/Plates Insulation: Common Fastened PSF: 195 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: ½" Vapor Retarder (Optional): 4-6 mil. Poly V-Force (SA) Primer BaseGard SA Primer DensDeck Cover Board: ½" min., 4' x 8' boards DensDeck Prime Insulation: 2"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board: 32 HD Fasteners/Plates Insulation: Common Fastened Membrane Options Cap: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Base: SBS Glass Torch Base SBS Poly Torch Base Cap: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Base: SBS Glass Torch Base SBS Poly Torch Base Cap: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Base: SBS Glass Torch Base SBS Poly Torch Base Membrane Attachment Cap: Torched Base: Torched Cap: Torched Base: Torched Cap: Torched Base: Torched RoofNav Number 395162394199-0 395164394199-0 395165394199-0 Page 64 June 20, 2018 SBS – Cap and Base Torched – Cover Board/Insulation Adhered – Concrete Deck Uplift PSF: 255 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: 1" Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Vapor Retarder: SBS Glass Torch Base SBS Poly Torch Base SBS Smooth Cover Board: ¼" min., 4' x 4' boards DensDeck DensDeck Prime Securock Attachment: Torched Primer (Permeable) Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board/ Insulation Attachment Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation: 12" o.c. beads ISO Spray R ISO Twin Pack Membrane Attachment Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: SBS Glass Torch Base SBS Poly Torch Base SBS Torch Base Cap: Torched Base: Torched RoofNav Number 231096200377-0 SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment Membrane Attachment Membrane Options RoofNav Number PSF: 90 Structural Concrete: 2,500 psi min. 2" thick min. Vapor Retarder: V-Force Primer SBS Torch Torched Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 8 HD or Concrete Drive Fasteners per board IF: NC EF: A Slope: 1" Hail: SH PSF: 90 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: 1" Hail: SH PSF: 90 Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: 1" Hail: SH Vapor Retarder: V-Force Primer SBS Torch Torched Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Securock None Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 12 HD or Concrete Drive Fasteners per board Cover Board: 16 HD or Concrete Drive Fasteners per board Insulation: Common Fastened Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Cap: Torched Base: Self Adhered Cap: Torched Base: Self Adhered Cap: Torched Base: Self Adhered 315272315082-0 315247315082-0 315223315082-0 Page 65 June 20, 2018 Continued SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 135 Structural Concrete: 2,500 psi min. 2" thick min. Vapor Retarder: V-Force Primer IF: NC EF: A Slope: ½" Hail: SH Cover Board: ½ʺ min., 4' x 4' boards DensDeck Prime Securock Insulation: 2"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board: 4" o.c. beads ISO Fix II ISO Spray R ISO Twin Pack ISO Stick Insulation: 32 HD or Concrete Drive Fasteners per board Membrane Options Cap: SBS FR Cap SBS FR Cap UW SBS FR Torch SBS FR Torch UW SBS Glass FR SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR SBS Premium FR Torch SBS Premium FR Torch UW SBS Premium FR UW Ply: SBS Glass Torch Base SBS Poly Torch Base Base: BaseGard SA Membrane Attachment RoofNav Number Cap: Torched Ply: Torched 390694389950-0 Base: Self-Adhered PSF: 165 Cover Board: ½ʺ min., 4' x 4' boards DensDeck Prime Securock Structural Concrete: 2,500 psi min. 2" thick min. None Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL/ RESISTA IF: NC EF: A Slope: 1" Hail: SH PSF: 165 Cover Board: ½ʺ min., 4' x 4' boards DensDeck Prime Securock Structural Concrete: 2,500 psi min. 2" thick min. None Insulation: 1½"-36ʺ, min. 4' x 4' boards ISO 95+ GL/ RESISTA IF: NC EF: A Slope: 1" Hail: SH PSF: 180 Cover Board: 4ʺ o.c. beads ISO Spray R ISO Twin Pack Insulation: 4ʺ o.c. beads ISO Twin Pack Cover Board: 4" o.c. beads ISO Spray R ISO Twin Pack Insulation: 4" o.c. beads ISO Twin Pack Structural Concrete: 2,500 psi min. 2" thick min. IF: NC EF: A Slope: 1" Hail: SH None Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 4" o.c. beads ISO Fix II Concrete Primer, Asphaltic, Permeable Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Cap: Torched Base: Self-Adhered Cap: Torched Base: Self-Adhered Cap: Torched Base: Self-Adhered 315808315082-0 315808315082-0 315771315082-0 Page 66 June 20, 2018 Continued SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 225 Structural Concrete: 2,500 psi min. 2" thick min. None Insulation: ½"-4", 4' x 4' boards Tapered ISO 95+ GL/ RESISTA Insulation: 1½"-36ʺ, min. 4' x 4' boards ISO 95+ GL/ RESISTA IF: NC EF: A Slope: 1" Hail: SH PSF: 270 None None Insulation: 8" o.c. beads ISO Fix II Concrete Primer, Asphaltic, Permeable None Cap: Torched Base: Self-Adhered 315786315082-0 Cap: SBS Premium Torch SBS Premium Torch UW SBS Smooth Torch SBS Torch SBS Torch UW Cap: Torched Base: Self-Adhered 315156315072-0 Concrete Primer, Asphaltic, Permeable None IF: NC EF: A Slope: 1" Hail: SH PSF: 435 Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL Insulation: 8" o.c. beads ISO Fix II Concrete Primer, Asphaltic, Permeable Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Cap: Torched Base: Self-Adhered 315778315082-0 Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cover Board: ½", 4' x 4' boards ISOGARD HD Structural Concrete: IF: NC EF: A Slope: 1" Hail: SH Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Structural Concrete: 2,500 psi min. 2" thick min. RoofNav Number Base: BaseGard SA IF: NC EF: C Slope: 5ʺ Hail: SH PSF: 420 2,500 psi min. 2" thick min. Membrane Attachment Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Structural Concrete: 2,500 psi min. 2" thick min. Membrane Options None 1"-2.5", 4' x 4' boards ISOGARD HD Composite Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 12" o.c. beads ISO Stick Twin Jet Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Cap: Torched Base: Self-Adhered 315909315082-0 Base: BaseGard SA Page 67 June 20, 2018 Continued SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 435 Cover Board: ½", 4' x 4' boards ISOGARD HD Structural Concrete: 2,500 psi min. 2" thick min. Cover Board/ Insulation None 1"-2.5", 4' x 4' boards ISOGARD HD Composite Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL IF: NC EF: A Slope: 1" Hail: SH Cover Board/ Insulation Attachment Membrane Attachment Membrane Options RoofNav Number Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation: 12" o.c. beads ISO Twin Pack Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Cap: Torched Base: Self-Adhered 315894315082-0 Base: BaseGard SA SBS –Torched – BaseGard SA– Cover Board/Insulation Attached – Steel Deck Uplift PSF: 90 IF: 1 EF: a Slope: 1" Hail: SH Steel: 22-16 ga 72ʺ span 33 ksi PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Steel: 22-16 ga 72ʺ span 33 ksi PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Steel: 22-16 ga 72" span 33 ksi Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 8 HD Fasteners per board SA Primer may be required. Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board: ½", 4' x 8' boards ISOGARD HD Insulation: 1½"-12", min. 4' x 8' boards ISO 95+ GL/ RESISTA Cover Board: ½", 4' x 8' boards DensDeck Prime Securock Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board: 12 HD Fasteners per board Insulation: Common Fastened Cover Board: 24 HD Fasteners per board Insulation: Common Fastened Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt Or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt or AcryliTop PC-100 Coat Cap: SBS FR Torch SBS FR Torch UW SBS Glass FR Torch SBS Glass FR Torch UW SBS Premium FR Torch SBS Premium FR Torch UW Base: BaseGard SA Membrane Attachment Cap: Torched Base: Self-Adhered Cap: Torched Base: Self-Adhered Cap: Torched Base: Self-Adhered RoofNav Number 315241315082-0 315871315082-0 315793315082-0 Page 68 June 20, 2018 Built-Up Roof – Hot Asphalt – Cover Board/Insulation – Steel Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Vapor Barrier: V-Force Primer: Permeable Thermal Barrier: 4' x 8' boards ¼" min, DensDeck ½ʺ min, Securock Cover Board: ¼", 4' x 4' boards DensDeck DensDeck Prime Securock Cover Board/ Insulation Attachment Membrane Attachment RoofNav Number Ply: Hot Asphalt 294792289016-0 Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Ply: Hot Asphalt 6085548535-0 Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (3) Type IV or VI Ply: Hot Asphalt 6085548536-0 Membrane Attachment RoofNav Number Ply: Hot Asphalt 294767289016-0 Ply: Hot Asphalt 6090148535-0 Membrane Options PSF: 90 IF: 1 EF: A Slope: 3" Hail: SH Steel: 22-16 ga 72ʺ span 33ksi PSF: 90 IF: 1 EF: A Slope: ½" Hail: SH 22-26 ga 72" span 33ksi PSF: 90 IF: 1 EF: A Slope: ½" Hail: SH 22-26 ga 72" span 33ksi Thermal Barrier (Optional): ⅝", 4' x 8' boards DensDeck DensDeck Prime Securock Common Fastened Thermal Barrier (Optional): ⅝", 4' x 8' boards DensDeck DensDeck Prime Securock Common Fastened Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Cover Board: ¼", 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 2.2"-4", 4' x 4' boards ISO 95+ GL Cover Board: ¼", 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 2.2"-4", 4' x 4' boards ISO 95+ GL Cover Board: 12" o.c. beads, ISO Stick Insulation: 12" o.c. beads, ISO Twin Pack ISO Stick Cover Board: Hot Asphalt Insulation: 10 HD Fasteners per board Cover Board: Hot Asphalt Insulation: 10 HD Fasteners per board Coating/Surfacing: Hot Asphalt/Gravel Ply: (3) Type IV or VI Built-Up Roof – Hot Asphalt – Cover Board/Insulation – Concrete Deck Uplift PSF: 90 IF: NC EF: A Slope: 3" Hail: SH 2,500 psi min. 2" thick min. PSF: 90 IF: NC EF: A Slope: ½ʺ Hail: SH 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Vapor Retarder: V-Force Primer, Permeable Thermal Barrier: ¼" min, 4' x 8' boards DensDeck ½" min, 4' x 8' boards Securock Thermal Barrier (Optional): ⅝" min, 4' x 8' boards DensDeck DensDeck Prime Securock Common Fastened Cover Board/ Insulation Cover Board: ¼", 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Cover Board: ¼" 4' x 4' boards DensDeck DensDeck Prime Securock Insulation: 2"-4", 4' x 4' boards ISO 95+ GL Cover Board/ Insulation Attachment Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack ISO Stick Insulation: 12" o.c. beads ISO Spray R ISO Twin Pack ISO Stick Thermal Barrier: 8 HD or Concrete Drive Fasteners Cover Board: Hot Asphalt Insulation: 8 HD Fasteners per board Membrane Options Coating/Surfacing: Hot Asphalt/Gravel Ply: (3) Type IV or VI Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Page 69 June 20, 2018 Continued Built-Up Roof – Hot Asphalt – Cover Board/Insulation – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 90 IF: NC EF: A Slope: ½ʺ Hail: SH None 2,500 psi min. 2" thick min. PSF: 90 IF: NC EF: A Slope: 3" Hail: SH None 2,500 psi min. 2" thick min. PSF: 90 IF: NC EF: A Slope: 3" Hail: SH None 2,500 psi min. 2" thick min. PSF: 90 Cover Board/ Insulation Cover Board: ½ʺ, 4' x 4' boards Structodek HD Cover Board/ Insulation Attachment ¼", 4' x 4' boards DensDeck Insulation: Hot Asphalt Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Cover Board: ½", 4' x 4' boards Structodek HD Substrate Primer: Asphaltic, Permeable ¼", 4' x 4' boards DensDeck Insulation: Hot Asphalt Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Cover Board: ½", 4' x 4' boards Structodek HD Substrate Primer: Asphaltic, Permeable ¼", 4' x 4' boards DensDeck Insulation: 2.2"-12", 4' x 4' boards ISO 95+ GL Cover Board: ¼", 4' x 4' boards Structodek HD IF: NC EF: A Slope: ½" Hail: SH Thermal Barrier (Optional): ⅝" min, 4' x 8' boards DensDeck DensDeck Prime Securock 2,500 psi min. 2" thick min. Common Fastened Insulation: 1½"-4", 4' x 4' boards ISO 95+ GL None None ¼", 4' x 4' boards DensDeck Cover Board: Hot Asphalt Cover Board: Hot Asphalt Cover Board: Hot Asphalt Insulation: 8 HD or Concrete Drive Fasteners per board Cover Board: Hot Asphalt Insulation: 10 HD or Concrete Drive Fasteners per board PSF: 180 IF: NC EF: A Slope: ½" Hail: SH 2,500 psi min. 2" thick min. None Membrane Options Membrane Attachment RoofNav Number Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Ply: Hot Asphalt 384866384844-0 Ply: Hot Asphalt 384868341562-0 Ply: Hot Asphalt 384852341561-0 Ply: Hot Asphalt 6089848535-0 Ply: Hot Asphalt 6085248535-0 Coating/Surfacing: Hot Asphalt/Gravel Ply: (3) Type IV or VI Coating/Surfacing: Hot Asphalt/Gravel Ply: (4) Type IV or VI Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Primer: Concrete Primer, Asphaltic, Permeable Page 70 June 20, 2018 Continued Built-Up Roof – Hot Asphalt – Cover Board/Insulation – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 180 IF: NC EF: A Slope: ½" Hail: SH None None None 2,500 psi min. 2" thick min. PSF: 525 IF: NC EF: A Slope: ½" Hail: SH None Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL 2,500 psi min. 2" thick min. Cover Board: ¼", 4' x 4' boards DensDeck Securock PSF: 525 IF: NC EF: A Slope: ½" Hail: SH Cover Board: ¼", 4' x 4' boards DensDeck Securock None 2,500 psi min. 2” thick min. Insulation (Top): 1"-4", 4' x 4' boards Tapered ISO 95+ GL Insulation (Bottom): 1½"-4", 4' x 4' boards ISO 95+ GL Cover Board: Hot Asphalt Insulation: Hot Asphalt Cover Board: Hot Asphalt Insulation (Top): Hot Asphalt Insulation (Bottom): Hot Asphalt PSF: 525 IF: NC EF: A Slope: ½" Hail: SH 2,500 psi min. 2" thick min. None Cover Board: ¼", 4' x 4' boards DensDeck Securock Insulation: 1½"-12", 4' x 4' boards Tapered ISO 95+ GL Cover Board: Hot Asphalt Insulation: Hot Asphalt Membrane Attachment RoofNav Number Ply: Hot Asphalt 6085248536-0 Ply: Hot Asphalt 6088148536-0 Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (3) Type IV or VI Ply: Hot Asphalt 6087948536-0 Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (3) Type IV or VI Ply: Hot Asphalt 6088148535-0 Membrane Options Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (3) Type IV or VI Primer: Concrete Primer, Asphaltic, Permeable Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (3) Type IV or VI Page 71 June 20, 2018 Built-Up Roof – Hot Asphalt – Cover Board/Insulation – LWIC Uplift PSF: 90 IF: 1 EF: A Slope: ½" Hail: SH Form Deck Cover Board/ Insulation LWC Coating/Surfacing: Celcore PVA Curing Compound Cover Board: 4' x 4' boards ½"-1½", Structodek HD ½" min. DensDeck Securock LWIC: Celcore (min 200 psi) 2" min. Insulation: 1"-12" EPS Cover Board: Full Coverage ISO Spray R Insulation: 1½"-4", 4′x4′ boards ISO 95+ GL LWIC: Celcore (min 200 psi) 0.125" min. Cover Board/ Insulation Attachment Insulation: Full Coverage ISO Spray R Membrane Options Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Membrane Attachment RoofNav Number Ply: Hot Asphalt 1794564853551014 Ply: (4) Type IV or VI Built-Up Roof – Hot Asphalt – Base Sheet Attached – No Cover Board/Insulation – LWIC Uplift PSF: 90 IF: 1 EF: A Slope: ½" Hail: SH PSF: 90 IF: 1 EF: A Slope: ½" Hail: SH PSF: 90 IF: 1 EF: A Slope: 3" Hail: SH Deck Steel (WR): 22 ga Span: max 72" Depth: 1½" LWC Coating/ Surfacing LWIC: Celcore (min 200 psi) 2" min. Insulation: 1"-12" EPS Celcore PVA Curing Compound Celcore (min 200 psi) 0.125" min. Steel (WR): 22 ga Span: max 72" Depth: 1½" Steel: Type BV 22 ga Span: 60" Depth: 1½" LWIC: Celcore (min 200 psi) 2" min. Insulation: 1"-12" EPS Celcore PVA Curing Compound Celcore (min 200 psi) 0.125" min. LWIC: Mearlcrete Lite-Crete (min 200 psi) 2" min. Insulation: 1"-12" EPS Mearlcrete Lite-Crete (min 200 psi) 0.125" min. Membrane Options Membrane Attachment RoofNav Number Coating/Surfacing: Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Base Sheet: Channel Venting MB Base Coating/Surfacing: Hot Asphalt/Gravel -andAcrylic Base Coat for Asphalt AcryliTop PC-100 Coat Aluminum Fibered Roof Coating Fibered Asphalt Emulsion Ply: (4) Type IV or VI Ply: Hot Asphalt Base Sheet: 1.7" LWC Base Ply Fastener Laps: 36.4" rows, 7" o.c. Field: 2 staggered field rows (equally spaced), 7" o.c. 183124853550912 Base Sheet: Channel Venting MB Base Coating/Surfacing: Hot Asphalt/Gravel None Ply: (4) Type IV or VI Base Sheet: Channel Venting MB Base Ply: Hot Asphalt Base Sheet: 1.7" LWC Base Ply Fastener Laps: 36.4" rows, 7" o.c. Field: 2 staggered field rows (equally spaced), 7" o.c. 62197485355091 Ply: Hot Asphalt Base Sheet: 1.7" LWC Base Ply Fastener Laps: 35.4" rows, 7" o.c. Field: 2 staggered field rows (equally spaced), 7" o.c. 622196221850919 Page 72 June 20, 2018 APP – 2 Ply – Cap/Base Torched – Cover Board/Insulation Attached – Steel Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment Membrane Options Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW PSF: 75 IF: 1 EF: A Slope: 1.5" Hail: SH Steel: 22-16 ga 72" span 33 ksi PSF: 75 IF: 1 EF: A Slope: ½" Hail: SH Steel 22-16 ga 72" span 33 ksi Thermal Barrier (Optional): ¼ʺ min., 4' x 8' boards DensDeck DensDeck Prime ⅜" min., 4' x 8' boards Securock Vapor Retarder: V-Force Substrate Primer: V-Force SB Primer, Permeable Thermal Barrier: ¼" min., 4' x 8' boards DensDeck DensDeck Prime ⅜" min., 4' x 8' boards Securock PSF: 90 IF: 1 EF: A Slope: ½" Hail: SH Steel: 22-16 ga 72" span 33 ksi Thermal Barrier (Optional): ¼" min., 4' x 8' boards DensDeck DensDeck Prime ⅜" min., 4' x 8' boards Securock Cover Board: ½ʺ min., 4' x 4' boards DensDeck Prime Securock Insulation: 2"-12", 4' x 8' boards ISO 95+ GL/ RESISTA Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock Insulation: 2"-12", 4' x 8' boards ISO 95+ GL/ RESISTA Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock Insulation (Top): ½"-9.8", 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 2.2"-4", 4' x 8' boards ISO 95+ GL/ RESISTA Insulation: 8 HD Fasteners per board Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation: 8 HD Fasteners per board Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation (Top): 12" o.c. beads ISO Twin Pack Insulation (Bottom): 8 HD Fasteners per board PSF: 165 IF: 1 EF: A Slope: 2" Hail: SH Steel (WR): 22-18 ga 72" span 33 ksi Thermal Barrier (Optional): 4 or 6-mil poly or V-Force over ¼" min., 4' x 8' boards DensDeck Cover Board: ½" min., 4′x4′ boards DensDeck Prime Securock Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL Cover Board: 24 HD Fasteners per board Insulation: Common Fastened Membrane Attachment Cap: Torched Base: Torched RoofNav Number 386053263335-0 Base Ply: APP 160 APP 170 Coating/Surfacing (Optional): Aluminum Fibered Roof Coating Cap Ply: APP 160 APP 180 APP 180 FR APP 180 FR UW APP 180 UW APP Premium FR APP Premium FR UW Base Ply: APP 160 APP 170 Coating/Surfacing (Optional): Aluminum Fibered Roof Coating Cap Ply: APP 160 APP 180 APP 180 FR APP 180 FR UW APP 180 UW APP Premium FR APP Premium FR UW Base Ply: APP 160 APP 170 APP 80 Glass Base APP Premium Base Coating/Surfacing: Hot Asphalt/Gravel Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW APP Premium FR APP Premium FR UW Base Ply: APP 160 Cap: Torched Base: Torched Cap: Torched Base: Torched Cap: Torched Base: Torched 386044323832-0 385473323832-0 328972169856-0 Page 73 June 20, 2018 Continued APP – 2 Ply – Cap/Base Torched – Cover Board/Insulation Attached – Steel Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Thermal Barrier (Optional): 4 or 6 mil poly or V-Force over ¼" min., 4' x 8' boards DensDeck Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL PSF: 165 IF: 1 EF: A Slope: 1.5" Hail: SH Steel (WR): 22-18 ga 72" span 33 ksi Cover Board/ Insulation Attachment Cover Board: 24 HD Fasteners per board Insulation: Common Fastened Membrane Attachment Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap Ply: APP 180 FR APP 180 FR UW APP Premium FR APP Premium FR UW Base Ply: APP 160 Cap: Torched Base: Torched RoofNav Number 328967169858-0 PSF: 195 IF: 1 EF: A Slope: 1½" Hail: SH Steel (WR): 20-18 ga 72" span 33 ksi 22 ga, 67ʺ span 33 ksi 22-18 ga 72ʺ span 80 ksi Thermal Barrier (Optional): 4 or 6-mil poly or V-Force over ¼ʺ min., 4' x 8' boards DensDeck Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cover Board: 24 HD Fasteners per board Insulation: Common Fastened Cap: Torched Cap Ply: APP 180 FR APP 180 FR UW APP Premium FR APP Premium FR UW Base: Torched 311554169858-0 Base Ply: APP 160 APP – 2 Ply – Cap Torched w/ MB Base – Cover Board/Insulation Attached – Steel Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 75 IF: 1 EF: C Slope: ½" Hail: SH Steel: 22-16 ga 72" span 33 ksi PSF: 90 IF: 1 EF: C Slope: ½" Hail: SH None None Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL Insulation: 1½"-4ʺ, 4' x 4' boards ISO 95+ GL Preliminary Cap Ply: APP 160 Cool APP 170 Cool APP 180 Cool APP 180 FR Cool APP 180 FR Cool UW Base Sheet: Channel Venting MB Base Pre-securement Cap: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW Base Sheet: Channel Venting Base MB Base Pre-securement Cap: APP 160 COOL APP 170COOL APP 180 COOL APP 180 FR COOL APP 180 FR COOL UW Base Sheet: Channel Venting Base MB Base 22-16 ga 72ʺ Span 33 ksi PSF: 90 IF: 1 EF: C Slope: ½" Hail: SH 22-16-ga 72" Span 33 ksi None Insulation: 2.3"-12", 4' x 4' boards ISO 95+ GL Membrane Options Membrane Attachment RoofNav Number Cap Ply: Multi-Purpose MB Cold Adhesive Base Sheet: HD Fasteners/Plates Lap: 32" o.c., 18" o.c. Field: (2) rows, 12" o.c., Staggered 127679127667-0 Cap: Torch Base Sheet: HD Fasteners/Plates Row: 35.4", 18" o.c. Field: 1 Row Staggered 6110548953-0 Cap: Multi-Purpose MB Cold Adhesive Base Sheet: HD Fasteners/Plates Row: 35.3", 12" o.c. Field: 2 Rows, 12" o.c. Staggered 390311258145-0 Page 74 June 20, 2018 APP – 2 Ply – Cap/Base Torched – Cover Board/Insulation Attached – Concrete Deck Uplift PSF: 90 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. PSF: 90 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. Vapor Barrier/ Thermal Barrier Vapor Retarder (Optional): V-Force (SA) Vapor Retarder (Optional): V-Force (SA) Cover Board/ Insulation Cover Board/ Insulation Attachment Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Insulation: 1½"-12", 4' x 4' boards ISO 95+ GL Pre-securement Pre-securement Membrane Options Cap: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW Base Sheet: Channel Venting Base MB Base Cap: APP 160 APP 170 APP 180 APP 180 FR COOL APP 180 FR COOL UW Base Sheet: Channel Venting Base, MB Base Membrane Attachment RoofNav Number Cap: Torch Base Sheet: HD or Concrete Drive Fasteners/Plates Row: 35.4", 18" o.c. Field: 1 Row Staggered Cap: MB Cold Base Sheet: HD or Concrete Drive Fasteners/Plates Row: 35.4", 12" o.c. Field: 2 Rows 12" o.c. Staggered 27840648953-0 278479258145-0 APP – 2 Ply – Cap Torched w/ MB Base – Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 240 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. None None None Membrane Options Cap: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW Base Ply: MB Base Membrane Attachment Cap: Torched Base Ply: Hot Asphalt RoofNav Number 6112648409-0 Concrete Primer, Asphaltic, Permeable APP – Hybrid – Cover Board/Insulation – Concrete Deck Uplift PSF: 90 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. PSF: 465 IF: NC EF: C Slope: ½" Hail: SH Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Concrete Primer, Asphaltic, Permeable Cover Board: ½ʺ min., 4' x 4' boards FiberTop E Structodek HD Insulation: 1½"-36", 4' x 4' boards ISO 95+ GL None Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Securock Insulation: 1"-36", 4' x 4' boards ISO 95+ GL/ RESISTA 2,500 psi min. 2" thick min. PSF: 480 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. None Cover Board: ¼" min., 4' x 4' boards DensDeck Prime Securock Insulation: 1"-36", 4' x 4' boards ISO 95+ GL/RESISTA Cover Board/ Insulation Attachment Cover Board: 12" o.c. beads ISO Fix II Insulation: 12" o.c. beads ISO Fix II Cover Board: 12" o.c. beads ISO Spray R Insulation: 12" o.c. beads ISO Spray R Cover Board: 12" o.c. beads ISO Spray R Insulation: 12" o.c. beads ISO Spray R Membrane Options Cap: APP 160, APP 170 APP 180 APP 180 FR APP 180 FR UW Ply: (2) Type IV or VI Cap: APP 160, APP 170 APP 180, APP 180 FR APP 180 FR UW APP Premium FR APP Premium FR UW Ply: APP 160, APP 170 Cap: APP 160, APP 170 APP 180, APP 180 FR APP 180 FR UW APP Premium FR APP Premium FR UW Base: MB Base (1) Type IV or VI Membrane Attachment Cap: Torched Ply: Hot Asphalt Cap: Torched Base: Torched Cap: Torched Base: Hot Asphalt RoofNav Number 17689848985-0 308098207187-0 306541297075-0 Page 75 June 20, 2018 APP - Hybrid – 3 Ply – Cover Board/Insulation – LWIC Deck Uplift PSF: 90 IF: 1 EF: C Slope: ½" Hail: SH Form Deck: See Listing Structure: Steel PSF: 90 IF: 1 EF: C Slope: ½" Hail: SH Form Deck: See Listing Structure: Steel Cover Board/ Insulation Coating/Surfacing: Celcore PVA Curing Compound LWIC: Celcore, 200 psi, min. 2" thick Insulation: EPS, 1"-12" LWIC: Celcore, 200 psi, min. 0.125" thick Coating/Surfacing: Celcore PVA Curing Compound LWIC: Celcore, 200 psi, min. 2" thick Insulation: EPS, 1"-12" LWIC: Celcore, 200 psi, min. 0.125" thick Membrane Options Membrane Attachment Cap: APP 160, APP 170 APP 180, APP 180 FR APP 180 FR UW Base: APP 160 APP 170 Base Sheet: APP 160 APP 80 Glass Base Channel Venting Base MB Base Cap: APP 160, APP 170 APP 180, APP 180 FR APP 180 FR UW APP 180 UW Base: MB Base, SBS Poly Base SBS Premium Base SBS Smooth (1) Type IV or VI Base Sheet: APP 160, APP 80 Glass Base Channel Venting Base MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Smooth Cap Ply: Torched RoofNav Number Base Ply: Torched 62275263335-50912 Base Sheet: 1.2"/1.7" LWC Base Ply Fasteners Lap: 36.4" o.c. @ 7" o.c. Field Rows: 2 Staggered @ 7" o.c. Cap Ply: Torched Base Ply: Hot Asphalt 62226-4898450912 Base Sheet: 1.2"/1.7" LWC Base Ply Fasteners Lap: 36.4" o.c. @ 7" o.c. Field Rows: 2 Staggered @ 7" o.c. APP – 2 Ply – Cap/Base Cold – Cover Board/Insulation Attached – Steel Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 60 IF: 1 EF: C Slope: ½ʺ Hail: SH Steel 22-16 ga 72" span, 33 ksi Thermal (Optional): 4' x 8' boards ¼" DensDeck ⅜" Securock Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL Insulation: 16 HD fasteners per board PSF: 75 IF: 1 EF: C Slope: ½" Hail: SH Steel: 22-16 ga 72" span, 33 ksi Thermal (Optional): 4' x 8' boards ¼" DensDeck ⅜" Securock Insulation: 2"-12", 4' x 8' boards ISO 95+ GL/RESISTA Insulation: 8 HD fasteners per board PSF: 90 IF: 1 EF: C Slope: ½" Hail: SH Steel: 22-16 ga 72" span, 33 ksi Thermal (Optional): 4' x 8' boards ¼" DensDeck ⅜" Securock Insulation: 2.2"-12", 4' x 8' boards ISO 95+ GL /RESISTA Insulation: 8 HD fasteners per board Membrane Options Cap Ply: APP 160 Cool APP 170 Cool APP 180 Cool APP 180 FR Cool APP 180 FR Cool UW Base Ply: MB Base Cap Ply: APP 160 Cool APP 170 Cool APP 180 Cool APP 180 FR Cool APP 180 FR Cool UW Base Ply: APP 160 Cool APP 170 Cool MB Base Cap Ply: APP 160 Cool APP 170 Cool APP 180 Cool APP 180 FR Cool APP 180 FR Cool UW Base Ply: MB Base, Type IV or VI Membrane Attachment Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 259567259562-0 385970323687-0 385367127664-0 Page 76 June 20, 2018 SBS – 2 Ply – Cap/Base Cold – Cover Board/Insulation Attached – Steel Deck Vapor Barrier/ Thermal Barrier Uplift Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 75 IF: 1 EF: A Slope: 75 Hail: SH Thermal (Optional): 4' x 8' boards ¼" DensDeck ⅜" Securock Steel: 22-16 ga 72" span 33 ksi Insulation: 1½"-12", 4′x8′ boards ISO 95+ GL Insulation: 16 HD fasteners per board PSF: 90 IF: 1 EF: A Slope: 1" Hail: SH Steel: 22-16 ga 72" span, 33 ksi Thermal (Optional): 4' x 8' boards ¼" DensDeck ⅜" Securock PSF: 255 IF: 1 EF: A Slope: 1" Hail: SH Steel (WR): 22-18 ga 72ʺ span, 33 ksi Thermal (Optional): 4' x 8' boards ¼" DensDeck ⅜" Securock Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL Cover Board: ¼" min., 4' x 8' boards DensDeck Prime Securock Insulation: 2.2"-12", 4' x 8' boards ISO 95+ GL Insulation: 16 HD fasteners per board Insulation: 16 HD fasteners per board Membrane Attachment Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap Ply: SBS FR Cap SBS FR Cap UW SBS Premium FR SBS Premium FR UW Base Ply: MB Base, Type IV or IV SBS Base, SBS Poly Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: SBS Base, SBS Poly Base SBS Premium Base Cap Ply: SBS FR Cap SBS FR Cap UW SBS Premium FR SBS Premium FR UW Base Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base (1) Type IV or VI Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 4770850688-0 2600502599820 31752450688-0 SBS – 2 Ply – Cap/Base Cold – Cover Board Adhered/Insulation Attached – Steel Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 75 IF: 1 EF: C Slope: 5” Hail: SH Steel: 22-16 ga 72" span 33 ksi Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck SA Primer may be required. Cover Board/ Insulation Cover Board: ¼" min., min. 4' x 4' boards DensDeck Prime Securock Cover Board/ Insulation Attachment Insulation: 2"-12", 4' x 8' boards ISO 95+ GL Insulation: 8 HD fasteners per board Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Membrane Options Cap Ply: SBS Cap SBS Cap UW SBS Premium SBS Premium UW Base Ply: MB Base SBS Base SBS Poly Base SBS Premium Base Membrane Attachment Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 236853236854-0 Page 77 June 20, 2018 SBS – 2 Ply – MB Cold Adhesive – Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Attachment Cover Board/ Insulation Membrane Options PSF: 60 IF: NC EF: A Slope: ½" Hail: SH Vapor Barrier (Optional): V-Force (SA), Primer may be required. Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL Insulation: 16 HD fasteners per board 2,500 psi min. 2" thick min. PSF: 75 IF: NC EF: A Slope: ½" Hail: SH Vapor Barrier (Optional): V-Force (SA), Primer may be required. Insulation: 14' x 8' "-12", 4' x 8' boards ISO 95+ GL Insulation: 16 HD fasteners per board 2,500 psi min. 2" thick min. PSF: 90 Vapor Barrier (Optional): IF: NC EF: A Slope: 1" Hail: SH 2,500 psi min. 2" thick min. V-Force (SA), Primer may be required. Insulation: 1½"-12", 4' x 8' boards ISO 95+ GL Insulation: 16 HD fasteners per board SBS Torch Torched Cap ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Cap ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base SBS Premium Poly Base SBS Smooth Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: SBS Base, SBS Poly Base SBS Premium Base Membrane Attachment Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 390658389944-0 390660389944-0 260054259982-0 SBS – 2 Ply – MB Cold Adhesive – Cover Board/Insulation Adhered – Concrete Deck Uplift Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 135 IF: NC EF: A Slope: ½" Hail: SH 2,500 psi min. 2" thick min. Cover Board: 1½"-2.5", 4' x 4' boards ISOGARD HD Comp. Cover Board: 12" o.c. beads ISO Stick Insulation: 1½"-36", 4' x 4' boards ISO 95+ GL Insulation: 12" o.c. beads ISO Stick Membrane Options Cap ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: MB Base SBS Base SBS Poly Base SBS Premium Base SBS Smooth Membrane Attachment Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 354339354337-0 Page 78 June 20, 2018 Continued SBS – 2 Ply – MB Cold Adhesive – Cover Board/Insulation Adhered – Concrete Deck Uplift Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 135 IF: NC EF: A Slope: 1" Hail: SH 2,500 psi min. 2" thick min. Insulation (Top): 1"-4", 4' x 4' boards ISO 95+ GL/RESISTA Insulation (Top): 12" o.c. beads ISO Spray R Insulation (Bottom): 1"-36", 4' x 4' boards ISO 95+ GL/RESISTA Insulation (Bottom): 12" o.c. beads ISO Spray R PSF: 765 IF: NC EF: A Slope: 1" Hail: SH 2,500 psi min. 2" thick min. Cover Board: ¼" min., 4' x 4' boards Securock Insulation: ½"-36", 4' x 4' boards ISO 95+ GL PSF: 765 IF: NC EF: A Slope: 1" Hail: SH 2,500 psi min. 2" thick min. Cover Board: ¼" min., 4' x 4' boards Securock Insulation: ½"-36", 4' x 4' boards ISO 95+ GL Primer (Optional): Asphaltic, Permeable Cover Board: Hot Asphalt (Full) 12" o.c. beads ISO Fix II ISO Stick Insulation: Hot Asphalt (Full) 12" o.c. beads ISO Fix II ISO Stick Primer (Optional): Asphaltic, Permeable Cover Board: Hot Asphalt (Full) 12" o.c. beads ISO Fix II ISO Stick Insulation: Hot Asphalt (Full) 12" o.c. beads ISO Fix II ISO Stick Membrane Attachment Membrane Options Cap ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: SBS Base SBS Poly Base SBS Premium Base SBS Smooth Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap ply: SBS FR Cap SBS FR Cap UW SBS Premium FR SBS Premium FR UW Base Ply: MB Base, SBS Base SBS Poly Base SBS Premium Base (1) Type IV or VI Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap ply: SBS FR Cap SBS FR Cap UW SBS Premium FR SBS Premium FR UW Base Ply: SBS Base, SBS Poly Base SBS Premium Base SBS Smooth Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 309240295652-0 21216850688-0 212174132170-0 SBS – 2 Ply – MB Cold Adhesive – No Cover Board/Insulation – Concrete Deck Uplift Deck Primer PSF: 285 IF: NC EF: A Slope: 1" Hail: SH 2,500 psi min. 2" thick min. None Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap ply: SBS FR Cap SBS FR Cap UW SBS Premium FR SBS Premium FR UW Base Ply: SBS Base, SBS Poly Base SBS Premium Base, SBS Smooth Membrane Attachment Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 132181132170-0 Page 79 June 20, 2018 Continued SBS – 2 Ply – MB Cold Adhesive – No Cover Board/Insulation – Concrete Deck Uplift Deck Primer Membrane Options Deck Primer: Asphaltic Permeable Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap ply: SBS FR Cap SBS FR Cap UW SBS Glass FR SBS Glass FR UW SBS Premium FR SBS Premium FR UW Base Ply: SBS Base SBS Poly Base SBS Premium Base PSF: 360 IF: NC EF: A Slope: 1" Hail: SH 2,500 psi min. 2" thick min. Membrane Attachment Cap Ply: Multi-Purpose MB Cold Adhesive Base Ply: Multi-Purpose MB Cold Adhesive RoofNav Number 260074259982-0 APP –Torched – BaseGard SA– Cover Board/Insulation Attached – Steel Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 90 Vapor Barrier (Optional): IF: 1 EF: C Slope: ½" Hail: SH Steel: 22-16 ga 72" span, 33 ksi PSF: 90 IF: 1 EF: C Slope: ½" Hail: SH Steel: 22-16 ga 72" span, 33 ksi 4-6 mil poly OR V-Force (SA) ¼ʺ min. DensDeck Cover Board/ Insulation Cover Board/ Insulation Attachment Insulation: 2"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 8 HD fasteners per board Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 16 HD fasteners per board Primer may be required. Vapor Barrier (Optional): 4-6 mil poly or V-Force (SA) ¼" min. DensDeck Primer may be required. Membrane Options Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Membrane Attachment Cap Ply: Torched Base Ply: Self-Adhered Cap Ply: Torched Base Ply: Self-Adhered RoofNav Number 315255315142-0 315186315142-0 APP –Torched – BaseGard SA– Cover Board/Insulation Attached – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 90 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2ʺ thick min. None Cover Board/ Insulation Cover Board: ½" min., min. 4' x 4' boards DensDeck Prime Securock Insulation: 1.½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Cover Board/ Insulation Attachment Cover Board: 24 HD or Concrete Drive Fasteners per board Insulation: Common Fastened PSF: 90 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. Vapor Barrier (Optional): V-Force (SA) or SBS Torch Primer may be required. Insulation: 1½"-12", min. 4' x 4' boards ISO 95+ GL/ RESISTA Insulation: 16 HD or Concrete Drive Fasteners per board Membrane Options Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Membrane Attachment Cap Ply: Torched Base Ply: Self-Adhered Cap Ply: Torched Base Ply: Self-Adhered RoofNav Number 315307315142-0 315199315142-0 Page 80 June 20, 2018 APP –Torched – BaseGard SA– Cover Board/Insulation Adhered – Concrete Deck Uplift Vapor Barrier/ Thermal Barrier PSF: 165 IF: NC EF: A Slope: 1½" Hail: SH None 2,500 psi min. 2" thick min. PSF: 165 IF: NC EF: C Slope: ½" Hail: SH None 2,500 psi min. 2" thick min. PSF: 165 IF: NC EF: C Slope: ½" Hail: SH Cover Board/ Insulation Attachment Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL/RESISTA Insulation: 12" o.c. beads ISO Twin Pack Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL/RESISTA Cover Board: ½" min., 4' x 4' boards DensDeck Prime Securock None Insulation: 1½"-36", min. 4' x 4' boards ISO 95+ GL/RESISTA 2,500 psi min. 2" thick min. PSF: 435 IF: NC EF: C Slope: ½" Hail: SH Cover Board/ Insulation Cover Board: ½" min., min. 4' x 4' boards DensDeck Prime Securock None Insulation: ½", 4' x 4' boards ISOGARD HD Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation: 8" o.c. beads ISO Fix II Substrate Primer: Concrete Primer, Asphaltic, Permeable Membrane Options Coating/Surfacing (Optional): Acrylic Base Coat for Asphalt AcryliTop PC-100 Coat Cap Ply: APP 180 FR APP 180 FR UW APP Premium FR APP Premium FR UW Base Ply: BaseGard SA Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Cover Board: 12" o.c. beads ISO Spray R ISO Twin Pack Insulation: 12" o.c. beads ISO Twin Pack Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Insulation: 4" o.c. beads ISO Fix II 2,500 psi min. 2" thick min. Membrane Attachment Cap Ply: Torched Base Ply: Self-Adhered Cap Ply: Torched Base Ply: Self-Adhered Cap Ply: Torched Base Ply: Self-Adhered Cap Ply: Torched Base Ply: Self-Adhered RoofNav Number 316697315147-0 315297315142-0 315309315142-0 315427315142-0 APP –Torched – BaseGard SA– No Insulation – Concrete Deck Uplift Substrate Primer Vapor Barrier/ Thermal Barrier Membrane Options None Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA PSF: 270 IF: NC EF: C Slope: ½" Hail: SH 2,500 psi min. 2" thick min. Concrete Primer Asphaltic Permeable Membrane Attachment Cap Ply: Torched Base Ply: Self-Adhered RoofNav Number 315281315142-0 Page 81 June 20, 2018 PP –Torched – BaseGard SA– Cover Board/Insulation – Concrete Deck – Re-Cover/Re-Roof Uplift Vapor Barrier/ Thermal Barrier Cover Board/ Insulation Cover Board/ Insulation Attachment PSF: 90 IF: NC EF: C Slope: ½" Hail: SH None Insulation: 1½"-36", 4' x 4' boards ISO 95+ GL/RESISTA Insulation: 8" o.c. beads, ISO Fix II Concrete Re-Cover PSF: 225 IF: NC EF: C Slope: ½" Hail: SH Concrete Re-Roof Insulation (Top): ½"-4", 4' x 4' boards ISO 95+ GL/RESISTA Insulation (Top): 12" o.c. beads, ISO Twin Pack Insulation (Bottom): 1½"-36", 4' x 4' boards ISO 95+ GL/RESISTA Insulation (Bottom): 12" o.c. beads, ISO Twin Pack None Membrane Options Membrane Attachment Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Cap Ply: APP 160 APP 170 APP 180 APP 180 FR APP 180 FR UW APP 180 UW Base Ply: BaseGard SA Cap Ply: Torched Base Ply: Self-Adhered Cap Ply: Torched Base Ply: Self-Adhered RoofNav Number 315298315142-0 315303315142-0 Page 82 June 20, 2018
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : clmccarter Create Date : 2018:06:20 09:09:32-05:00 Modify Date : 2018:06:20 11:16:33-05:00 XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Format : application/pdf Title : Microsoft Word - Asphalt Code Approval Guide Creator : clmccarter Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2018:06:20 11:16:33-05:00 Producer : Acrobat Distiller 15.0 (Windows) Document ID : uuid:bf82beb6-eb6c-45f0-9884-8c7963458dfd Instance ID : uuid:124c2c72-ff4d-4b5f-9071-8e1c61ab80de Page Count : 82EXIF Metadata provided by EXIF.tools