Product Data Sheet Emerson Mobrey Level Transmitter MSP400RH Ip2045

User Manual: Emerson Mobrey Level Transmitter MSP400RH

Open the PDF directly: View PDF PDF.
Page Count: 12

DownloadProduct Data Sheet Emerson Mobrey Level Transmitter MSP400RH Ip2045
Open PDF In BrowserView PDF
Product Data Sheet
February 2015
IP2045, Rev EA

Mobrey Ultrasonic
MSP422, MSP400RH, and MSP900GH Level Transmitters



Non-contacting measurement with no
moving parts



Two integral signal relays for the
Mobrey MSP400RH



Integral LCD and push-buttons as standard for
on-site programming



Easy to install and configure





Continuous measurement of level or
distance-to-surface.

Rugged metal or plastic housing.
PVDF wetted material



Two-wire direct current loop-powered



Volume or open channel flow calculations for
the Mobrey MSP400RH and MSP900GH

Mobrey MSP422, MSP400RH and MSP900GH

February 2015

Overview of the Mobrey MSP422/400RH/900GH
Measurement principle
The Mobrey MSP Series is a liquid level transmitter based on
ultrasonic technology that is suitable for many liquid
applications.
Ultrasonic pulse signals are transmitted and reflected from the
liquid surface. The transmitter ‘listens’ for reflected signals
(echoes) and measures the time-delay between transmitting
and receiving. The distance to the liquid surface is automatically
calculated using the computed time-delay.

Mobrey MSP422

An integral temperature sensor continuously measures the air
temperature around the transmitter. It then computes the
speed of sound in air, automatically compensating the Distance
for temperature effects. The MSP400RH and MSP900GH have a
Remote Temperature Sensor option.
The distance measurement can be sent through the 4–20 mA or
HART® output.

Features and benefits

Mobrey MSP400RH

Mobrey MSP900GH



Eliminates problems experienced with contacting
instrumentation



Simple set-up and operation



Minimal maintenance after installed



Low cost of installation and commissioning



Process downtime minimized



Non-contacting measurement with no moving parts



Two integral signal relays



Corrosion resistant PVDF wetted material



Two-wire 24 V direct current loop-powered



M20 x 1.5 conduit entries, single or dual depending on model



Operating range to 36 ft. (11 m)



Measures liquid height, distance to liquid, volume, or flow in
open channels



Simple push button programming



Built-in LCD display



Automatic temperature compensation

Contents
Overview of the Mobrey MSP422/400RH/900GH . . . . . . page 2

MSP Series Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4

Mobrey MSP422 Level Transmitter . . . . . . . . . . . . . . . . . . . page 4

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5

Mobrey MSP400RH Level Transmitter . . . . . . . . . . . . . . . . page 4

Product Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8

Mobrey MSP900GH Level Transmitter . . . . . . . . . . . . . . . . page 4

Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9

2

www.emersonprocess.com

February 2015

Mobrey MSP422, MSP400RH and MSP900GH

Special features
Advanced software features


Learn routine (false echo registration)
The transmitter can learn to ignore up to four false echoes
caused by the pulse signal reflecting off obstructions, until
the actual level is seen.



Empty tank mapping

Remote Temperature Sensor Option
(For MSP400RH and MSP900GH)

When a tank is empty, the transmitter can learn to ignore up
to four false echoes, without the need for user interaction.


Present depth
The bottom reference can be automatically set using a known
user-entered depth.



Set as empty
When the tank is empty, the bottom reference can be
automatically reset to the measured distance.



Distance offset
The distance to the surface can be adjusted by a user-entered
positive or negative offset value.



Level offset
The level can be adjusted by a user-entered positive or
negative offset value



Bottom blanking
The transmitter can be set to ignore an area of the tank
bottom to avoid false echoes from obstructions.

Level Measurement with a Mobrey MSP400RH Transmitter
and a Mobrey MCU900 Series Control Unit

Applications


Storage tank levels, open channel flow, effluent pits,
reservoir level, buffer tanks, and more

Choosing the right model


Each MSP Series transmitter has been designed for a specific
purpose, as shown in the table here:

Transmitter Purpose

Model

Range

Simple level measurement

MSP422
MSP400RH

26-ft. (8 m)
36-ft. (11 m)

Level measurement and local relays

MSP400RH

36-ft. (11 m)

Level measurement in hazardous
areas

MSP900GH

36-ft. (11 m)

Open channel flow or volume
measurement

MSP400RH
MSP900GH

36-ft. (11 m)
36-ft. (11 m)

www.emersonprocess.com

Open Channel Flow Measurement with
a Mobrey MSP900GH Transmitter

3

Mobrey MSP422, MSP400RH and MSP900GH

February 2015

Mobrey MSP422 Level Transmitter
Table 1. MSP422 ordering information
Model

Product Description

MSP422
Ultrasonic Level Transmitter 4–20mA
Process Connection
N2(1)

2-in. NPT thread

B2(2)
2-in. BSPT thread
Wetted Material
8
PVDF
Typical Model Number:

MSP422 - B2 8

(1) Choosing this option implies US (Imperial) units of measurement are required for the default configuration. The configuration can be changed on-site.
(2) Choosing this option implies Metric units of measurement are required for the default configuration. The configuration can be changed on-site.

Mobrey MSP400RH Level Transmitter
Table 2. MSP400RH ordering information
Model

Product Description

MSP400R
Ultrasonic Level Transmitter with 2 integral relays
Signal Output
H
4–20 mA with HART communication
Process Connection
N2(1)

2-in. NPT thread

B2(2)
2-in. BSPT thread
Wetted Material
8
PVDF
Typical Model Number:

MSP400R H - B2 8

(1) Choosing this option implies US (Imperial) units of measurement are required for the default configuration. Configuration can be changed on-site.
(2) Choosing this option implies Metric units of measurement are required for the default configuration. Configuration can be changed on-site.

Mobrey MSP900GH Level Transmitter
Table 3. MSP900GH ordering information
Model

Product Description

MSP900G
Ultrasonic Level Transmitter for hazardous areas
Signal Output
H
4–20 mA with HART communication
Process Connection and Approval
A
2-in. BSPT thread, PVDF wetside, and ATEX approved Intrinsically Safe
Typical Model Number: MSP900G H - A

MSP Series Accessories
Table 4. MSP Series accessories ordering information
Accessories
MSP-FLG5

2-in. BSPT to PN16 DN50, PVC Flange

MSP-BRK3(1)
MSP-BRK2(1)

2-in. NPT Mounting Bracket

MSP-RTP

Remote Temperature Sensor (Mobrey MSP400RH and Mobrey MSP900GH only)

2-in. BSPT Mounting Bracket

(1) See “Dimensional Drawings” on page 9.

4

www.emersonprocess.com

February 2015

Mobrey MSP422, MSP400RH and MSP900GH

Specifications
General
Products






Mobrey MSP422 Ultrasonic Transmitter:
Level and Distance measurement
Mobrey MSP400RH Ultrasonic Transmitter:
Level, Distance, Content (Volume), and Flow measurement,
with two integral signal relays
Mobrey MSP900GH Ultrasonic Transmitter:
Level, Distance, Content (Volume), and Flow measurement for
hazardous locations

Output units


For Level or distance-to-surface: m, ft, in, or none



For Contents: l, m3, gal, ft3, or none



For Flow:
l/s, l/m, m3/hr, gal/s, gal/m, ft3/m (cfm), ft3/hr, or none

Output variables


MSP422: Level or distance-to-surface



MSP400RH:
Level (or distance-to-surface), Content (Volume), and Flow



MSP900GH:
Level (or distance-to-surface), Content (Volume), and Flow

Measurement principle


Ultrasonic, time-of-flight

Measuring performance
Measurement range

Configuration tools


Standard integral push-buttons with LCD



Field Communicator



Mobrey MCU900 Series Universal Control Unit



Mobrey MSP422: 1 to 26 ft. (0,3 to 8 m)



Mobrey MSP400RH: 1 to 36 ft. (0,3 to 11 m)

Electrical



Mobrey MSP900GH: 1 to 36 ft. (0,3 to 11 m)

Power supply

Blanking distance (dead zone)


12 in. (0,3 m)

Level resolution


Better than 0.06 in. (1 mm)



Loop-powered (two-wire)



Mobrey MSP422: 12 to 30 Vdc



Mobrey MSP400RH: 12 to 40 Vdc



Mobrey MSP900GH:
12 to 40 Vdc (non-hazardous area),
12 to 30 Vdc (hazardous area)

Level accuracy under reference conditions(1)




MSP422:
± 0.2 in. (5 mm) for < 3.3 ft. (1 m),

Earthing

± 0.5% of measured distance for > 3.3 ft. (1 m)



MSP400RH and MSP900GH:
± 0.1 in. (2,5 mm) < 3.3 ft (1 m),
± 0.25% of measured distance for > 3.3 ft. (1 m)

Current output

Update interval


Display: 500 ms



Current Output: 200 ms

Display and configuration
Integral display


4/5 digit display for live measurement, and for configuration
purposes

(1)

None required



MSP422: Analog 4–20 mA



MSP400RH and MSP900GH: Analog 4–20 mA, HART

Signal on alarm


Low = 3.6 mA. High = 21 mA

Saturation levels


Low = 3.8 mA. High = 20.5 mA

Relay output (MSP400RH)
 Two integral signal relays, SPST rated 1A @ 30 Vdc (inductive) and

2A @ 30 Vdc (resistive)

Temperature: 68 °F (20 °C), Pressure: 1013 mbar (atmospheric pressure), Relative Humidity: 50%, calm and stable water surface.

www.emersonprocess.com

5

Mobrey MSP422, MSP400RH and MSP900GH

February 2015

Electrical parameters (MSP900GH)

Weight of transmitter

 Ui = 30 V, li = 120 mA, Pi = 0,82 W, Li = 108 H, Ci = 0 nF



MSP422: 2.0 lb (0,9 kg)

Cable entry



MSP400RH: 2.2 lb (1,0 kg)

 Two M20 x 1.5 conduit entries for cable glands



MSP900GH: 3.1 lb (1,4 kg)

Output cabling
 Single twisted-pair and shielded,

min. 0,22 mm2 (24 AWG),
max. 1,5 mm2 (15 AWG)

Physical specifications

Measuring
Temperature compensation(1)


MSP422: Automatic Integral temperature compensation



MSP400RH: Automatic Integral temperature compensation.
Optional remote temperature sensor for dynamic
temperature compensation



MSP900GH: Automatic Integral temperature compensation.
Optional remote temperature sensor for dynamic
temperature compensation

Materials selection


Emerson provides a variety of product with various product
options and configurations including materials of
construction that can be expected to perform well in a wide
range of applications. The product information presented is
intended as a guide for the purchaser to make an appropriate
selection for the application. It is the purchaser’s sole
responsibility to make a careful analysis of all process
parameters (such as all chemical components, temperature,
pressure, flow rate, abrasives, contaminants, etc.), when
specifying product, materials, options and components for
the particular application. Emerson Process Management is
not in a position to evaluate or guarantee the compatibility of
the process fluid or other process parameters with the
product, options, configuration or materials of construction
selected.

Materials used in construction
Wet-side material


Glass-filled nylon

Cover seal


Silicone rubber

Cover screws


316 Stainless Steel

Transducer body seal


Ambient temperature(2)


MSP422:
–4 to 158 °F (–20 to 70 °C)



MSP400RH:
–40 to 158 °F (–40 to 70 °C)



MSP900GH:
–40 to 140 °F (–40 to 60 °C)

Process temperature


MSP422:
–4 to 158 °F (–20 to 70 °C)



MSP400RH and MSP900GH:
–22 to 158 °F (–30 to 70 °C)

PVDF

Body and cover material


Environment

EPDM

Process pressure:


–4 to 44 psi (–0,25 to 3,0 bar)

Ingress protection


IP 66/67 (when using supplied cable gland/blanking plug)

Electromagnetic compatibility
 EN61326 (Class B)

Certifications


CE-mark, FM, ATEX (dependent on order code)

Mechanical
Mounting thread size


6

2-in. NPT, or 2-in. BSP. Optional flange accessories available

(1)
(2)

See Table 4 on page 4 for optional accessories.
See page 8 onwards for approval temperature ranges.

www.emersonprocess.com

February 2015

Mobrey MSP422, MSP400RH and MSP900GH

Temperature and pressure ratings
The process temperature/pressure rating depends on the design of the transmitter in combination with the flange materials.
Pressure
psi (bar)

44 psi
(3 bar)

OPERATING RANGE
The final rating may be limited
by flange selection
Temperature
°F (°C)

–4 psi
(–0,25 bar)
–4 °F (–20 °C) for MSP422
–22 °F (–30 °C) for others

158 °F
(70 °C)

Process Temperature And Pressure Diagram For Mobrey MSP422, MSP400RH and MSP900GH

Load limitations
A Field Communicator requires a minimum load resistance of 250 Ohm within the loop in order to function properly. Communication
with Mobrey MCU900 Series Control Unit does not require additional resistance. The maximum load resistance can be determined
from these diagrams:
Intrinsically Safe Installations

Non-Intrinsically Safe Installations
R (Ohms)

R (Ohms)

R (Ohms)

1244

1244

1244

Mobrey MSP900GH

Mobrey MSP400RH

Mobrey MSP422
800

800
533

533

533

800

400

400

250

0

U (V)

0

24
0

12

20

250

400

30

0

24

18
12

20

U (V)
30

40

U (V)

0
0

12

24

18
20

30

R (Ohms)
1244
Mobrey MSP900GH
533

800

250

400
U (V)

0

18
12

www.emersonprocess.com

24
20

30

40

Note
R = Maximum Load Resistance
U = External Power Supply Voltage

7

Mobrey MSP422, MSP400RH and MSP900GH

February 2015

Product Certifications
Approved manufacturing locations


Rosemount Measurement Limited
– Slough, United Kingdom

European directive information
The EC declaration of conformity certificate may be obtained by
contacting your local sales office.
ATEX directive (94/9/EC)


The MSP900GH complies with the ATEX directive

Pressure equipment directive (PED) (97/23/EC)


The MSP Series is outside the scope of the PED directive

Electro magnetic compatibility (EMC) directive


EN 61326-1:2006, EN 61326-2.3:2006

CE-mark


MSP422 (EMC)



MSP400RH (EMC)



MSP900GH (EMC, ATEX)

Hazardous locations certification
(Mobrey MSP900GH only)
European certification
ATEX intrinsically safe approval
Certificate number: SIRA 02ATEX2405X
ATEX intrinsic safety (Mobrey MSP900GH only)
II 1 G
Ex ia IIC T6 Ga (Ta –40 to 55 °C)
Ex ia IIC T4 Ga (Ta –40 to 60 °C)
Ui = 30 V, li = 120 mA, Pi = 0.82 W, Li = 108 H, Ci = 0 F
Special conditions for safe use
1. All transmitter models have external plastic parts, which could
present a risk of ignition due to electrostatic charge build-up.
They shall not be directly installed in any process where its
enclosure might be charged by the rapid flow of non-conductive
media.
2. All transmitter models shall only be cleaned with a damp cloth.
3. When the transmitter housing uses aluminum alloy in its
construction, this presents a risk of ignition due to impact and
shall be taken into consideration on installation and use.

Ordinary locations certification
(Mobrey MSP422 and MSP400RH only)
American certification
Factory Mutual (FM) ordinary locations approval
Project ID: 3015615
The transmitter has been examined and tested to determine
that the design meets basic electrical, mechanical, and fire
protection requirements by FM, a nationally recognized testing
laboratory (NRTL) as accredited by the Federal Occupational
Safety and Health Administration (OSHA).

8

www.emersonprocess.com

February 2015

Mobrey MSP422, MSP400RH and MSP900GH

Dimensional Drawings
Threaded mounting (MSP422)
Note: Dimensions are in inches (mm).

3 (77)

4.5 (113.5)

MSP422

2.36 (60) A/F Hexagon

2-in. Thread

Ø2
(Ø51)

5.6 (142)

1.9 (48)

1.9 (47)
3.8
(96)

5.5
(138.5)
8
(202.5)
M20 x 1.5
Cable Entry

www.emersonprocess.com

9

Mobrey MSP422, MSP400RH and MSP900GH

February 2015

Threaded mounting (MSP400RH/MSP900GH)
Note: Dimensions are in inches (mm).

3 (77)

4.5 (113.5)

2.36 (60) A/F Hexagon

2-in. NPT/BSPT Thread

Ø2
(Ø51)

5.6 (142)

1.9 (48)

1.9 (47)
3.8
(96)

5.5
(138.5)
8
(202.5)

10

Two M20 x 1.5 Cable Entries
One Fitted With Cable Gland;
The Other Plugged

www.emersonprocess.com

February 2015

Mobrey MSP422, MSP400RH and MSP900GH

2-in. NPT/BSPT bracket kits
Note: Dimensions are in inches (mm).

Note: The combined weight of
bracket and disc is 16 oz. (0,5 kg).
2-in. NPT/BSPT
Threaded PVC Disc
0.51
(13)

Stainless Steel Bracket
SIDE VIEW

4.33
(110)

0.35
(9)
2.26
(57)

Ø
(Ø 1.0
26 2
)

2.95
(75)

)
,5
(6 .
26 P
0. T Y

END VIEW
1.5
(38)

2.24
(57)

No. 4X 13 Long Self Tap
Screw (3 Positions)
Carbon Steel (Zinc Plated)
4.02
(102)

ACTUAL VIEW WITH
TRANSMITTER MOUNTED

www.emersonprocess.com

11

Mobrey MSP422, MSP400RH and MSP900GH
IP2045, Rev EA

Emerson Process Management
Rosemount Measurement Ltd.
158 Edinburgh Avenue
Slough, Berks, SL1 4UE, UK
Tel: +44 (0)1753 756600
Fax: +44 (0)1753 823589
www.emersonprocess.com

Product Data Sheet
February 2015

Emerson Process Management
Rosemount Inc.
8200 Market Boulevard
Chanhassen, MN 55317, USA
T (USA) 1 800 999 9307
T (International) +1 952 906 8888
F +1 952 906 8889

Standard Terms and Conditions of Sale can be found at www.rosemount.com\terms_of_sale
The Emerson logo is a trade mark and service mark of Emerson Electric Co.
Mobrey and the Mobrey logotype are registered trademarks of Rosemount Measurement Ltd.
Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc.
HART is a registered trademark of the HART Communication Foundation.
All other marks are the property of their respective owners.
© 2015 Rosemount Measurement Ltd. All rights reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Create Date                     : 1999:02:04 16:49:40Z
Modify Date                     : 2015:04:18 04:40:03+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : FrameMaker 8.0
Metadata Date                   : 2015:04:18 04:40:03+08:00
Format                          : application/pdf
Creator                         : 
Title                           : Product Data Sheet: Mobrey Ultrasonic MSP422, MSP400RH, and MSP900GH Level Transmitters
Document ID                     : uuid:aede4bcf-04b3-45fb-9269-7813fc32b4d0
Instance ID                     : uuid:92effa72-e38f-4177-8007-93fa8c3bbac6
Page Mode                       : UseNone
Page Count                      : 12
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu