75 137.5 DCG600 Modine 137
User Manual: DCG600
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
75-137.5 May, 2004 Commercial & Industrial Applied Product Line Heating Ventilating Cooling Make-Up Air MODINE COMMERCIAL & INDUSTRIAL APPLIED PRODUCT LINE Modine has always been the industry standard in the commercial and industrial comfort-heating market. With the Modine product line, you can solve your application needs with duct furnaces and direct-fired or indirect-fired make-up air systems, with heating capacities up to 7,862,000 Btu/hr. Available in indoor and outdoor configurations, air-handling capacities are as high as 60,000 CFM. Modine sales representatives are experienced specialists in the engineering, selection and application of Modine commercial and industrial heating and ventilating equipment. Located near you, these representatives can help you satisfy your comfort needs and indoor air-quality requirements. Contact your Modine product source for assistance in providing top-quality, high-efficiency Indoor Air Solutions. 2 CONTENTS PAGE Indoor Gas-Fired Duct Furnaces Heating and/or Make-up Air Units 4 Indoor Gas-Fired System Units Heating, Cooling, Ventilating, and Make-Up Air Units 5 Indoor Gas-Fired Separated Combustion Duct Furnace Heating and/or Make-up Air Units 6 Indoor Gas-Fired Separated Combustion System Units Heating, Cooling, Ventilating, and Make-Up Air Units 7 WeatherHawkTM Weatherproof Gas-Fired Duct Furnace Heating and/or Make-Up Air Units 8 WeatherHawkTM Weatherproof Gas-Fired System Units Heating, Cooling, Ventilating, and Make-Up Air Units 9 Direct-Fired Make-Up Air Units 10 3 INDOOR GAS-FIRED GRAVITY VENTED DUCT FURNACE HEATING AND/OR MAKE-UP AIR UNITS • Low Initial Cost • Applications Cover Heating and/or Make-Up Air • 75,000 to 400,000 Btu/Hr Input Capacity • Low Maintenance • Easy to Service The Modine indoor gravity vented duct furnace was designed for use with a building’s heating, heating/cooling and make-up air systems. Modine gravity vented duct furnaces are specifically designed for lost cost installations. Available in 11 model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 400,000 Btu/Hr and can operate on either natural or propane gas. The airflow direction can be specified when ordering the unit. The duct furnace is certified for location either upstream or downstream from cooling coils and has a drain pan that allows connection to a condensate drain line. MODEL DFG Standard Features: • C.S.A. certification – bearing C.S.A. logos • ETL certification • All units a minimum of 80% thermally efficient • 20 gauge aluminized steel cabinet • Certified to 3.0" W.C. external static pressure Optional Features: • 409 stainless steel heat exchanger and burner • 409 stainless steel drip pan • Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas • Building management compatible gas controls for modulation control using 0 - 10 Vdc or 4 - 20 mA input • High and/or low gas pressure switches Performance Data ➀➁ Btu/Hr Model No. Input Output DFG 75 DFG100 DFG125 DFG150 DFG175 DFG200 DFG225 DFG250 DFG300 DFG350 DFG400 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 Low Temperature High Temperature Temperature Rise Temperature Rise CFM Range CFM Range Range (°F) Range (°F) 20 - 60 926 - 2,778 20 - 100 556 - 2,778 20 - 60 1,235 - 3,704 20 - 100 741 - 3,704 20 - 60 1,543 - 4,630 20 - 100 926 - 4,630 20 - 60 1,852 - 5,556 20 - 100 1,111 - 5,556 20 - 60 2,160 - 6,481 20 - 100 1,296 - 6,481 20 - 60 2,469 - 7,407 20 - 100 1,481 - 7,407 20 - 60 2,778 - 8,333 20 - 100 1,667 - 8,333 20 - 60 3,086 - 9,259 20 - 100 1,852 - 9,259 20 - 60 3,704 - 11,111 20 - 100 2,222 - 11,111 20 - 60 4,321 - 12,963 23 - 100 2,593 - 11,111 20 - 60 4,938 - 14,815 27 - 100 2,963 - 11,111 ➀ Ratings are shown for elevations up to 2,000 feet. ➁ Units approved for use in California by CEC. DO NOT LOCATE ANY GAS-FIRED UNIT IN AREAS WITH CHLORINATED, HALOGENATED OR ACIDIC VAPORS IN ATMOSPHERE. Request Catalog 5-173 For Complete Technical Information and Specifications. 4 INDOOR GAS-FIRED GRAVITY VENTED SYSTEM UNITS HEATING, COOLING, VENTILATING, AND MAKE-UP AIR UNITS • Applications Cover Heating-Only, Heating/Ventilating, Cooling, and/or Make-Up Air • 75,000 to 1,200,000 Btu/Hr Input Capacity • Large Selection of Blower Fan/Drive and Motor Combination Available • Easy to Service The Modine indoor gravity vented duct furnace with blower and/or cooling sections was designed for use with a building’s heating, heating/ventilating/cooling and make-up air systems. Modine gravity vented duct furnaces are specifically designed for low cost installations. Available in 17 model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas. The airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others. MODEL DBG Standard Features: • ETL certification of the entire system unit • 18 gauge insulated aluminized steel blower cabinet with a baked-on polyester powder paint finish on exterior casing parts • Blower performance up to 3.0" W.C. external static pressure Optional Features: • DX or chilled water section with factory installed cooling coil • Double wall construction for blower and/or cooling cabinet • Dead-front disconnect switches • Two position, modulating, building pressure sensing, three position, building management (0 - 10 Vdc or 4 - 20 mA input) damper actuators • Blower and motor vibration isolation Performance Data Model No. DBG/DCG75 DBG/DCG100 DBG/DCG125 DBG/DCG150 DBG/DCG175 DBG/DCG200 DBG/DCG225 DBG/DCG250 DBG/DCG300 DBG/DCG350 DBG/DCG400 DBG/DCG500 DBG/DCG600 DBG/DCG700 DBG/DCG800 DBG/DCG840 DBG/DCG900 Btu/Hr Input ➀ 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 500,000 600,000 700,000 800,000 1,050,000 1,200,000 Btu/Hr Temperature Output ➀ Rise Range (°F) 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 400,000 480,000 560,000 640,000 840,000 960,000 20 20 20 20 23 23 26 20 20 22 25 40 40 40 41 60 63 - 100 100 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120 CFM Range 556 - 2,778 741 - 3,704 926 - 4,630 1,111 - 5,556 1,296 - 5,556 1,481 - 6,500 1,667 - 6,500 1,852 - 9,259 2,222 - 11,111 2,593 - 12,000 2,963 - 12,000 3,086 - 9,259 3,704 - 11,111 4,321 - 12,963 4,938 - 14,500 6,481 - 12,963 7,407 - 14,500 Total Static Pressure Range (Inches w.c.) 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 ➀ Ratings are shown for elevations up to 2000 feet. Cooling Coil Performance Data Model No. 75 100/125 150/175 200/225 250/300 350/400 Cooling Coil Max. Cooling Tons ➁ Maximum CFM DX Coil➂ Chilled Water Coil➂ 1,891 9.38 10.56 2,206 11.43 12.62 2,521 13.42 14.77 3,352 18.12 19.28 3,724 20.24 21.33 5,214 27.26 29.25 ➁ 1 Ton = 12,000 Btu/Hr ➂ Based on 95°F entering dry bulb, 75°F entering wet bulb Request Catalog 5-173 For Complete Technical Information and Specifications. 5 INDOOR GAS-FIRED SEPARATED COMBUSTION DUCT FURNACE HEATING AND/OR MAKE-UP AIR UNITS • Low Initial Cost • Applications Cover Heating and/or Make-Up Air • 75,000 to 400,000 Btu/Hr Input Capacity • Low Maintenance • Easy to Service The Modine indoor separated combustion duct furnace was designed for use with a building’s heating, heating/cooling and make-up air systems. Modine separated combustion duct furnaces are specifically designed for buildings with hostile atmospheric conditions, such as high humidity or negative pressures. Available in 11 power exhausted model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 400,000 Btu/Hr and can operate on either natural or propane gas. The airflow direction can be specified when ordering the unit. The duct furnace is certified for location either upstream or downstream from cooling coils and has a drain pan that allows connection to a condensate drain line. MODEL DFS Standard Features: • C.S.A. certification – bearing C.S.A. logos • ETL certification • All units a minimum of 80% thermally efficient • 20 gauge aluminized steel cabinet • Certified to 3.0" W.C. external static pressure • Separate electrical, venting, and gas control access with fully gasketed doors Optional Features: • 409 stainless steel heat exchanger and burner • 409 stainless steel drip pan • Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas • Building management compatible gas controls for modulation control using 0 - 10 Vdc or 4 - 20 mA input • High and/or low gas pressure switches Performance Data ➀➁ Btu/Hr Model No. Input Output DFS 75 DFS100 DFS125 DFS150 DFS175 DFS200 DFS225 DFS250 DFS300 DFS350 DFS400 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 Low Temperature High Temperature Temperature Rise Temperature Rise CFM Range CFM Range Range (°F) Range (°F) 20 - 60 926 - 2,778 20 - 100 556 - 2,778 20 - 60 1,235 - 3,704 20 - 100 741 - 3,704 20 - 60 1,543 - 4,630 20 - 100 926 - 4,630 20 - 60 1,852 - 5,556 20 - 100 1,111 - 5,556 20 - 60 2,160 - 6,481 20 - 100 1,296 - 6,481 20 - 60 2,469 - 7,407 20 - 100 1,481 - 7,407 20 - 60 2,778 - 8,333 20 - 100 1,667 - 8,333 20 - 60 3,086 - 9,259 20 - 100 1,852 - 9,259 20 - 60 3,704 - 11,111 20 - 100 2,222 - 11,111 20 - 60 4,321 - 12,963 23 - 100 2,593 - 11,111 20 - 60 4,938 - 14,815 27 - 100 2,963 - 11,111 ➀ Ratings are shown for elevations up to 2,000 feet. ➁ Units approved for use in California by CEC. DO NOT LOCATE ANY GAS-FIRED UNIT IN AREAS WITH CHLORINATED, HALOGENATED OR ACIDIC VAPORS IN ATMOSPHERE. Request Catalog 5-173 For Complete Technical Information and Specifications. 6 INDOOR GAS-FIRED SEPARATED COMBUSTION SYSTEM UNITS HEATING, COOLING, VENTILATING, AND MAKE-UP AIR UNITS • Applications Cover Heating-Only, Heating/Ventilating, Cooling, and/or Make-Up Air • 75,000 to 1,200,000 Btu/Hr Input Capacity • Large Selection of Blower Fan/Drive and Motor Combination Available • Easy to Service The Modine indoor separated combustion duct furnace with blower and/or cooling sections was designed for use with a building’s heating, heating/ventilating/cooling and make-up air systems. Modine separated combustion duct furnaces are specifically designed for buildings with hostile atmospheric conditions, such as high humidity or negative pressures. Available in 17 power exhausted model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas. The airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others. MODEL DBS Standard Features: • ETL certification of the entire system unit • 18 gauge insulated aluminized steel blower cabinet with a baked-on polyester powder paint finish on exterior casing parts • Blower performance up to 3.0" W.C. external static pressure • Separate electrical, venting, and gas control access with fully gasketed doors Optional Features: • DX or chilled water section with factory installed cooling coil • Double wall construction for blower and/or cooling cabinet • Dead-front disconnect switches • Two position, modulating, building pressure sensing, three position, building management (0 - 10 Vdc or 4 - 20 mA input) damper actuators • Blower and motor vibration isolation Performance Data Model No. DBS/DCS75 DBS/DCS100 DBS/DCS125 DBS/DCS150 DBS/DCS175 DBS/DCS200 DBS/DCS225 DBS/DCS250 DBS/DCS300 DBS/DCS350 DBS/DCS400 DBS/DCS500 DBS/DCS600 DBS/DCS700 DBS/DCS800 DBS/DCS840 DBS/DCS900 MODEL DCS Btu/Hr Input ➀ 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 500,000 600,000 700,000 800,000 1,050,000 1,200,000 Btu/Hr Temperature Output ➀ Rise Range (°F) 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 400,000 480,000 560,000 640,000 840,000 960,000 20 20 20 20 23 23 26 20 20 22 25 40 40 40 41 60 63 - 100 100 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120 CFM Range 556 - 2,778 741 - 3,704 926 - 4,630 1,111 - 5,556 1,296 - 5,556 1,481 - 6,500 1,667 - 6,500 1,852 - 9,259 2,222 - 11,111 2,593 - 12,000 2,963 - 12,000 3,086 - 9,259 3,704 - 11,111 4,321 - 12,963 4,938 - 14,500 6,481 - 12,963 7,407 - 14,500 Total Static Pressure Range (Inches w.c.) 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 ➀ Ratings are shown for elevations up to 2000 feet. Cooling Coil Performance Data Model No. 75 100/125 150/175 200/225 250/300 350/400 Cooling Coil Max. Cooling Tons ➁ Maximum CFM DX Coil➂ Chilled Water Coil➂ 1,891 9.38 10.56 2,206 11.43 12.62 2,521 13.42 14.77 3,352 18.12 19.28 3,724 20.24 21.33 5,214 27.26 29.25 ➁ 1 Ton = 12,000 Btu/Hr ➂ Based on 95°F entering dry bulb, 75°F entering wet bulb Request Catalog 5-173 For Complete Technical Information and Specifications. 7 WEATHERHAWKTM WEATHERPROOF GAS-FIRED DUCT-FURNACE HEATING AND/OR MAKE-UP AIR UNITS • Low Initial Cost • Applications Cover Heating and/or Make-Up Air • 75,000 to 400,000 Btu/Hr Input Capacity • Low Maintenance • Easy to Service The Modine WeatherHawk weatherproof duct furnace was designed for use with a building’s heating, heating/cooling and make-up air systems. Available in 11 gravity or power vented model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 400,000 Btu/Hr and can operate on either natural or propane gas. The airflow direction can be specified when ordering the unit. The duct furnace is certified for location either upstream or downstream from cooling coils and has holes to drain any condensate that may form onto the roof. MODEL HFG Standard Features: • C.S.A. certification – bearing C.S.A. logos • ETL certification • All units a minimum of 80% thermal efficient • 18 gauge aluminized steel cabinet with a baked-on polyester powder paint finish on exterior casing parts • Certified to 3.0” W.C. external static pressure Optional Features: • 409 stainless steel heat exchanger and burner • 409 stainless steel drip pan • Two-stage, mechanical modulation, and electronic modulation controls for either natural or propane gas. • Building management compatible gas controls for modulation control using 0 - 10 Vdc or 4 - 20 mA input • High and/or low gas pressure switches MODEL HFP Performance Data Model No. HFG/HFP75 HFG/HFP100 HFG/HFP125 HFG/HFP150 HFG/HFP175 HFG/HFP200 HFG/HFP225 HFG/HFP250 HFG/HFP300 HFG/HFP350 HFG/HFP400 ➀➁ Btu/Hr Input Output 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 Low Temperature High Temperature Temperature Rise Temperature Rise CFM Range CFM Range Range (°F) Range (°F) 20 - 60 926 - 2,778 20 - 100 556 - 2,778 20 - 60 1,235 - 3,704 20 - 100 741 - 3,704 20 - 60 1,543 - 4,630 20 - 100 926 - 4,630 20 - 60 1,852 - 5,556 20 - 100 1,111 - 5,556 20 - 60 2,160 - 6,481 20 - 100 1,296 - 6,481 20 - 60 2,469 - 7,407 20 - 100 1,481 - 7,407 20 - 60 2,778 - 8,333 20 - 100 1,667 - 8,333 20 - 60 3,086 - 9,259 20 - 100 1,852 - 9,259 20 - 60 3,704 - 11,111 20 - 100 2,222 - 11,111 20 - 60 4,321 - 12,963 23 - 100 2,593 - 11,111 20 - 60 4,938 - 14,815 27 - 100 2,963 - 11,111 ➀ Ratings are shown for elevations up to 2,000 feet. ➁ Units approved for use in California by CEC. Request Catalog 5-173 For Complete Technical Information and Specifications. 8 WEATHERHAWKTM WEATHERPROOF GAS-FIRED SYSTEM UNITS HEATING, COOLING, VENTILATING, AND MAKE-UP AIR UNITS • Applications Cover Heating-Only, Heating/Ventilating, Cooling, and/or Make-Up Air • 75,000 to 1,200,000 Btu/Hr Input Capacity • Large Selection of Blower Fan/Drive and Motor Combination Available • Easy to Service The Modine weatherproof duct furnace with blower, cooling, and/or downturn plenum sections was designed for use with a building’s heating, heating/ventilating/cooling and make-up air systems. Available in 17 gravity or power vented model sizes, the unit covers a wide variety of applications. They have input ranges from 75,000 to 1,200,000 Btu/Hr and can operate on either natural or propane gas.The airflow ranges from 556 to 14,500 CFM and the airflow direction can be specified when ordering the unit. The unit can be provided with a cooling coil section with either a factory installed DX or chilled water cooling coil or the coil can be provided by others. MODEL HBG Standard Features: • ETL certification of the entire system unit • 18 gauge insulated aluminized steel cabinet with a baked-on polyester powder paint finish on exterior casing parts • Blower performance up to 3.0” W.C. external static pressure • Side or bottom (through a roof curb) gas and electrical connection access Optional Features: • DX or chilled water section with factory installed cooling coil. • Double wall construction for blower, cooling cabinet, and/or downturn plenum sections • Dead-front disconnect switches • Two position, modulating, building pressure sensing, three position, building management (0 - 10 Vdc or 4 - 20 mA input) damper actuators • Blower and motor vibration isolation Performance Data MODEL HDG Model No. ➀ Btu/Hr Input ➁ Btu/Hr Output ➁ HBG/HCG/HDG/HPG75 HBG/HCG/HDG/HPG100 HBG/HCG/HDG/HPG125 HBG/HCG/HDG/HPG150 HBG/HCG/HDG/HPG175 HBG/HCG/HDG/HPG200 HBG/HCG/HDG/HPG225 HBG/HCG/HDG/HPG250 HBG/HCG/HDG/HPG300 HBG/HCG/HDG/HPG350 HBG/HCG/HDG/HPG400 HBG/HCG/HDG/HPG500 HBG/HCG/HDG/HPG600 HBG/HCG/HDG/HPG700 HBG/HCG/HDG/HPG800 HBG/HCG/HDG/HPG840 HBG/HCG/HDG/HPG960 75,000 100,000 125,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 500,000 600,000 700,000 800,000 1,050,000 1,200,000 60,000 80,000 100,000 120,000 140,000 160,000 180,000 200,000 240,000 280,000 320,000 400,000 480,000 560,000 640,000 840,000 960,000 Temperature Rise Range (°F) 20 20 20 20 23 23 26 20 20 22 25 40 40 40 41 60 63 - 100 100 100 100 100 100 100 100 100 100 100 120 120 120 120 120 120 CFM Range 556 - 2,778 741 - 3,704 926 - 4,630 1,111 - 4,630 1,296 - 5,556 1,481 - 6,500 1,667 - 6,500 1,852 - 9,259 2,222 - 11,111 2,593 - 12,000 2,963 - 12,000 3,086 - 9,259 3,704 - 11,111 4,321 - 12,963 4,938 - 14,500 6,481 - 12,963 7,401 - 14,500 Total Static Pressure Range (Inches w.c.) 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 0 - 3.0 ➀ For power exhausted units, the "G” in the model number is replaced with a "P" ➁ Ratings are shown for elevations up to 2,000 feet. Cooling Coil and Evaporative Cooling Performance Data MODEL HPG Model No. 75 100/125 150/175 200/225 250/300 350/400 Cooling Coil Max. Cooling Tons ➂ Maximum CFM Water DX Coil➃ Chilled Coil➃ 1,891 9.38 10.56 2,206 11.43 12.62 2,521 13.42 14.77 3,352 18.12 19.28 3,724 20.24 21.33 5,214 27.26 29.25 Evaporative Cooling Btu/Hr Maximum CFM Min. Max. 2,750 4,000 5,200 6,000 10,400 11,050 9,968 13,125 19,198 24,952 37,916 44,247 52,272 54,432 70,762 81,648 141,523 150,368 ➂ 1 Ton = 12,000 Btu/Hr ➃ Based on 95°F entering dry bulb, 75°F entering wet bulb Request Catalog 5-173 For Complete Technical Information and Specifications. 9 DIRECT-FIRED MAKE-UP AIR UNITS • ETL Certified • Btu/Hr Outputs from 42,000 to 7,862,000 • CFM Ranges from 1,600 to 60,000 • 100% Make-Up Air and Recirculating Configurations • 100% Thermal Efficiency • Designed for Indoor or Outdoor Mounting • Factory-Assembled Natural or Propane Gas Manifolds Modine has developed the best in direct-fired, make-up-air units - the MDB (Single and Two Speed 100% Make-Up Air) and MRB (Fresh and Return Air). These units are designed to provide an economical and efficient means of supplying tempered make-up air to a space or building. Available in eight airflow configurations, the units cover a wide variety of applications. MODEL MDB/MRB Standard Features: • 100% thermal efficiency (92% sensible) results in lower fuel bills. • Units are designed for indoor or outdoor mounting, providing flexibility in applications or design, as well as simplifying installation. • Natural or propane gas manifolds are factory-assembled to provide flexible fuel options and to reduce field-installation, start-up costs and problems. • Factory-wired electrical panel with numbered terminals significantly reduces start-up delays. • 100% factory flame-testing eliminates the majority of field start-up problems caused by defective controls. • Weatherproof roof with drip ledge provides protection from water being drawn into the unit from the roof. • 18-gauge galvanized steel casing provides high corrosion protection for long life. • Adjustable drives through 10 HP simplify air balancing and eliminates the need to change drives. • Four access doors provide maximum access for easy adjustments and service. • 22:1 firing rate turndown for optimum temperature control. Optional Features: • V-bank filter section • Inlet hood • Inlet damper • Discharge damper • Evaporative cooling • IRI and FM manifold arrangements • Discharge air temperature control, space temperature control, or building management (0-10 Vdc or 4-20 mA input) control • High and low gas pressure switches • Internal blower and motor vibration isolation • Acrylic paint finish on exterior casing parts Request Catalog 5-160 For Complete Technical Information and Specifications. 10 DIRECT-FIRED MAKE-UP AIR UNITS Performance Data CFM Range SCFM ➀ Maximum Output (Btu/Hr) ➀ MDB/MRB110 1,600-3,300 432,400 Natural Gas Maximum Temperature Rise ( F) ➀ 115 MDB/MRB112 2,000-4,700 615,800 115 MDB/MRB115 3,000-6,500 851,700 115 0-2.6” 1-5 MDB/MRB118 3,500-10,000 1,310,300 115 0-3.0” 1 1/2-10 MDB/MRB120 6,000-13,500 1,769,000 115 0-3.0” 2-15 MDB/MRB122 8,000-16,500 2,162,100 115 0-3.0” 3-20 MDB/MRB125 10,000-21,500 2,817,300 115 0-3.0” 3-20 MDB/MRB127 12,000-26,000 3,406,900 115 0-2.5” 3-20 MDB/MRB130 14,000-30,000 3,931,100 115 0-2.7” 5-25 MDB/MRB215 9,000-13,000 1,703,400 115 0-2.3” 5-10 MDB/MRB218 12,500-18,500 2,424,200 115 0-3.0” 5-20 MDB/MRB220 18,000-27,000 3,538,000 115 0-3.0” 7 1/2-25 MDB/MRB222 25,000-33,000 4,324,200 115 0-3.0” 15-30 MDB/MRB225 30,000-46,000 6,027,700 115 0-3.0” 15-40 MDB/MRB230 44,000-60,000 7,862,200 115 0-2.7” 20-50 Model No. Total Static Pressure Range (" W.C.) Horsepower Range 0-2.8” 3/4-3 0-3.0” 3/4-5 ➀ CFM, Btu/Hr capacities & Temperature Rise vary depending on unit configuration and certification. The Maximum Temperature Rise for propane gas is 85°F. Evaporative Cooling Option Apparent Cooling Capacities - based on EAT of 85°F dry bulb and 65°F wet bulb ➁ Model No CFM Range Min. Max. 12" Media Cooling ➂ Capacity Range (Btu/Hr) Min. Max. MDB/MRB110 1,600 3,300 33,178 65,578 MDB/MRB112 2,000 4,700 40,608 91,876 MDB/MRB115 3,000 6,500 61,560 127,764 MDB/MRB118 3,500 10,000 71,064 193,320 MDB/MRB120 6,000 13,500 121,824 263,898 MDB/MRB122 8,000 16,500 158,976 318,978 MDB/MRB125 10,000 21,500 199,800 417,960 MDB/MRB127 12,000 26,000 239,760 505,440 MDB/MRB130 14,000 30,000 276,696 576,720 MDB/MRB215 9,000 13,000 176,904 254,124 MDB/MRB218 12,500 18,500 243,000 355,644 MDB/MRB220 18,000 27,000 353,808 524,880 MDB/MRB222 25,000 33,000 486,000 634,392 MDB/MRB225 30,000 46,000 589,680 894,240 MDB/MRB230 44,000 60,000 855,360 1,153,440 ➁ The term “apparent cooling” is used because the cooling capacity will vary based on the entering air dry-bulb and wet-bulb temperatures, as well as the CFM through the unit. ➂ Available with CelDek or GlasDek media Request Catalog 5-160 For Complete Technical Information and Specifications. 11 The Modine brand has been the industry standard since Arthur B. Products from Modine are designed to provide indoor air-comfort solutions for commercial, institutional and industrial applications. Whatever your heating, ventilating and cooling requirements, Modine has the product to satisfy your Modine invented and patented the needs, including: first lightweight, suspended hydronic • Gas-fired unit heaters unit heater in 1923. No other • Gas-fired duct furnaces manufacturer can provide the • Gas-fired high-intensity infrared heaters combined application flexibility, technical expertise and fast delivery found at Modine. Consult your local • Gas-fired low-intensity infrared heaters • Steam/hot water unit heaters • Steam/hot water cabinet unit heaters Modine distributor for help in solving • Steam/hot water commercial fin tube radiation your indoor air problems. • Oil-fired unit heaters • Electric unit heaters • Indoor gravity vented single and multiple duct furnace make-up air units • Indoor separated combustion single and multiple duct furnace make-up air units • Outdoor single and multiple duct furnace make-up air units • Direct-fired make-up air units With burner capacities up to 7,862,000 Btu/hr and air-handling capacities as high as 60,000 CFM, Modine products are compatible with every fuel type, including: • Natural or Propane Gas • Steam/Hot Water • Oil • Electric Specific catalogs and computer-generated heat-loss calculations are available for each product. Catalogs 75-136 and 75-137 provide details on all Modine HVAC equipment. Distributed By: Commercial HVAC&R Division Modine Manufacturing Company 1500 DeKoven Avenue Racine, Wisconsin 53403-2552 Phone: 1.800.828.4328 (HEAT) Fax: 262.636.1665 www.modine.com © Modine Manufacturing Company 2004 C5/04 - 20M Litho in USA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Page Count : 12 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:3a3301a9-c294-406d-9ff9-56d9ad0890af Producer : Acrobat Distiller 5.0 (Windows) Create Date : 2004:05:04 15:31:48Z Modify Date : 2004:05:04 15:31:48Z Metadata Date : 2004:05:04 15:31:48Z Creator Tool : AdobePS5.dll Version 5.2 Document ID : uuid:ee9c7beb-db30-4090-8e5a-9217330db4c8 Format : application/pdf Title : 75-137.5.qxd Creator : AdobePS5.dll Version 5.2EXIF Metadata provided by EXIF.tools