IRONMAN OM 198 683C O198683c Hob

OM-198 683C to the manual c9aee045-f842-4ce7-a8d9-4603335e71b6

User Manual: IRONMAN OM-198 683C

Open the PDF directly: View PDF PDF.
Page Count: 44

DownloadIRONMAN OM-198 683C O198683c Hob
Open PDF In BrowserView PDF
OM-198 683C
April 2000

Processes
MIG (GMAW) Welding
Flux Cored (FCAW) Welding

Description

Arc Welding Power Source
and Wire Feeder

R

IronMan 275
With Meters

And M-25 Gun

Visit our website at

www.HobartWelders.com

From Hobart to You
Thank you and congratulations on choosing Hobart.
Now you can get the job done and get it done right.
We know you don’t have time to do it any other way.
This Owner’s Manual is designed to help you get the
most out of your Hobart products. Please take time
to read the Safety precautions. They will help you
protect yourself against
potential hazards on the
worksite. We’ve made
installation and operation
quick and easy. With Hobart you can count on
years of reliable service with proper
maintenance. And if for some reason the unit
Hobart is registered to the needs repair, there’s a Troubleshooting section
ISO 9001 Quality System
that will help you figure out what the problem
Standard.
is. The parts list will then help you to decide
which exact part you may need to fix the
problem. Warranty and service information for
your particular model are also provided.

Hobart Welders manufactures a full line
of welders and welding related equipment.
For information on other quality Hobart
products, contact your local Hobart distributor
to receive the latest full line catalog or
individual catalog sheets. To locate your nearest
distributor or service agency call 1-877-Hobart1.

Working as hard as you
do – every power source
from Hobart is backed by
the best warranty in the
business.

Hobart offers a Technical
Manual which provides
more detailed service and
parts information for your
unit. To obtain a Technical
Manual, contact your local
distributor. Your distributor
can also supply you with
Welding Process Manuals
such as SMAW, GTAW,
GMAW, and GMAW-P.

TABLE OF CONTENTS

WARNING
This product, when used
for welding or cutting,
produces fumes or
gases which contain
chemicals known to the
State of California to
cause birth defects and,
in some cases, cancer.
(California Health &
Safety Code Section
25249.5 et seq.)

The following terms are
used interchangeably
throughout this manual:
MIG = GMAW

OM-198 683C

SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . .
1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . .
1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-2. Dangers relatifs au soudage à l’arc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-4. Principales normes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-5. Information sur les champs électromagnétiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 2 – INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-2. Welding Power Source Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-3. Welding Gun Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-4. Volt-Ampere Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-5. Installing Work Clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-6. Installing Welding Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-7. Connecting Olympic 30A Gun . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-8. Setting Gun Polarity For Wire Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-9. Installing Gas Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-10. Installing Wire Spool and Adjusting Hub Tension . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-11. Positioning Jumper Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-12. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-13. Selecting A Location And Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-14. Threading Welding Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-15. Weld Parameter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 3 – OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1. Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-2. Voltmeter And Wire Feed Speed Meter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 4 – MAINTENANCE &TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-2. Circuit Breaker CB1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-3. Unit Overload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-4. Replacing Gun Contact Tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-5. Changing Drive Roll and Wire Inlet Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-6. Aligning Drive Rolls and Wire Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-7. Cleaning Or Replacing Gun Liner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-8. Replacing Switch And/Or Head Tube . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-9. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 5 – ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SECTION 6 – PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WARRANTY

1
1
1
3
3
4
5
5
5
7
8
8
9
9
9
10
10
11
11
11
12
12
13
13
14
14
15
16
18
18
19
20
20
20
20
21
21
22
23
24
25
27
28

SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING
som _nd_4/98

1-1. Symbol Usage
Means Warning! Watch Out! There are possible hazards
with this procedure! The possible hazards are shown in
the adjoining symbols.
Y Marks a special safety message.

. Means “Note”; not safety related.

This group of symbols means Warning! Watch Out! possible
ELECTRIC SHOCK, MOVING PARTS, and HOT PARTS hazards.
Consult symbols and related instructions below for necessary actions
to avoid the hazards.

1-2. Arc Welding Hazards
Y The symbols shown below are used throughout this manual to
call attention to and identify possible hazards. When you see
the symbol, watch out, and follow the related instructions to
avoid the hazard. The safety information given below is only
a summary of the more complete safety information found in
the Safety Standards listed in Section 1-4. Read and follow all
Safety Standards.

D If earth grounding of the workpiece is required, ground it directly
with a separate cable.

Y Only qualified persons should install, operate, maintain, and
repair this unit.

D Wear a safety harness if working above floor level.
D Keep all panels and covers securely in place.

Y During operation, keep everybody, especially children, away.

D Clamp work cable with good metal-to-metal contact to workpiece
or worktable as near the weld as practical.

ELECTRIC SHOCK can kill.
Touching live electrical parts can cause fatal shocks
or severe burns. The electrode and work circuit is
electrically live whenever the output is on. The input
power circuit and machine internal circuits are also
live when power is on. In semiautomatic or automatic wire welding, the
wire, wire reel, drive roll housing, and all metal parts touching the
welding wire are electrically live. Incorrectly installed or improperly
grounded equipment is a hazard.

D Do not touch electrode if you are in contact with the work, ground,
or another electrode from a different machine.
D Use only well-maintained equipment. Repair or replace damaged
parts at once. Maintain unit according to manual.

D Insulate work clamp when not connected to workpiece to prevent
contact with any metal object.
D Do not connect more than one electrode or work cable to any
single weld output terminal.

SIGNIFICANT DC VOLTAGE exists after removal of
input power on inverters.
D Turn Off inverter, disconnect input power, and discharge input
capacitors according to instructions in Maintenance Section
before touching any parts.

D Do not touch live electrical parts.
D Wear dry, hole-free insulating gloves and body protection.
D Insulate yourself from work and ground using dry insulating mats
or covers big enough to prevent any physical contact with the work
or ground.
D Do not use AC output in damp areas, if movement is confined, or if
there is a danger of falling.
D Use AC output ONLY if required for the welding process.
D If AC output is required, use remote output control if present on
unit.
D Disconnect input power or stop engine before installing or
servicing this equipment. Lockout/tagout input power according to
OSHA 29 CFR 1910.147 (see Safety Standards).
D Properly install and ground this equipment according to its
Owner’s Manual and national, state, and local codes.

D Keep your head out of the fumes. Do not breathe the fumes.

D Always verify the supply ground – check and be sure that input
power cord ground wire is properly connected to ground terminal in
disconnect box or that cord plug is connected to a properly
grounded receptacle outlet.
D When making input connections, attach proper grounding conductor first – double-check connections.
D Frequently inspect input power cord for damage or bare wiring –
replace cord immediately if damaged – bare wiring can kill.
D Turn off all equipment when not in use.
D Do not use worn, damaged, undersized, or poorly spliced cables.

D Do not weld in locations near degreasing, cleaning, or spraying operations. The heat and rays of the arc can react with vapors to form
highly toxic and irritating gases.

D Do not drape cables over your body.

FUMES AND GASES can be hazardous.
Welding produces fumes and gases. Breathing
these fumes and gases can be hazardous to your
health.

D If inside, ventilate the area and/or use exhaust at the arc to remove
welding fumes and gases.
D If ventilation is poor, use an approved air-supplied respirator.
D Read the Material Safety Data Sheets (MSDSs) and the
manufacturer’s instructions for metals, consumables, coatings,
cleaners, and degreasers.
D Work in a confined space only if it is well ventilated, or while
wearing an air-supplied respirator. Always have a trained watchperson nearby. Welding fumes and gases can displace air and
lower the oxygen level causing injury or death. Be sure the breathing air is safe.

D Do not weld on coated metals, such as galvanized, lead, or
cadmium plated steel, unless the coating is removed from the weld
area, the area is well ventilated, and if necessary, while wearing an
air-supplied respirator. The coatings and any metals containing
these elements can give off toxic fumes if welded.

OM-198 683 Page 1

ARC RAYS can burn eyes and skin.
Arc rays from the welding process produce intense
visible and invisible (ultraviolet and infrared) rays
that can burn eyes and skin. Sparks fly off from the
weld.
D Wear a welding helmet fitted with a proper shade of filter to protect
your face and eyes when welding or watching (see ANSI Z49.1
and Z87.1 listed in Safety Standards).
D Wear approved safety glasses with side shields under your
helmet.
D Use protective screens or barriers to protect others from flash and
glare; warn others not to watch the arc.
D Wear protective clothing made from durable, flame-resistant material (leather and wool) and foot protection.

BUILDUP OF GAS can injure or kill.
D Shut off shielding gas supply when not in use.
D Always ventilate confined spaces or use
approved air-supplied respirator.

HOT PARTS can cause severe burns.
D Do not touch hot parts bare handed.
D Allow cooling period before working on gun or
torch.

MAGNETIC FIELDS can affect pacemakers.

WELDING can cause fire or explosion.
Welding on closed containers, such as tanks,
drums, or pipes, can cause them to blow up. Sparks
can fly off from the welding arc. The flying sparks, hot
workpiece, and hot equipment can cause fires and
burns. Accidental contact of electrode to metal objects can cause
sparks, explosion, overheating, or fire. Check and be sure the area is
safe before doing any welding.
D Protect yourself and others from flying sparks and hot metal.
D Do not weld where flying sparks can strike flammable material.
D Remove all flammables within 35 ft (10.7 m) of the welding arc. If
this is not possible, tightly cover them with approved covers.
D Be alert that welding sparks and hot materials from welding can
easily go through small cracks and openings to adjacent areas.
D Watch for fire, and keep a fire extinguisher nearby.
D Be aware that welding on a ceiling, floor, bulkhead, or partition can
cause fire on the hidden side.
D Do not weld on closed containers such as tanks, drums, or pipes,
unless they are properly prepared according to AWS F4.1 (see
Safety Standards).
D Connect work cable to the work as close to the welding area as
practical to prevent welding current from traveling long, possibly
unknown paths and causing electric shock and fire hazards.
D Do not use welder to thaw frozen pipes.
D Remove stick electrode from holder or cut off welding wire at
contact tip when not in use.
D Wear oil-free protective garments such as leather gloves, heavy
shirt, cuffless trousers, high shoes, and a cap.
D Remove any combustibles, such as a butane lighter or matches,
from your person before doing any welding.

FLYING METAL can injure eyes.
D Welding, chipping, wire brushing, and grinding
cause sparks and flying metal. As welds cool,
they can throw off slag.
D Wear approved safety glasses with side
shields even under your welding helmet.

OM-198 683 Page 2

D Pacemaker wearers keep away.
D Wearers should consult their doctor before
going near arc welding, gouging, or spot
welding operations.

NOISE can damage hearing.
Noise from some processes or equipment can
damage hearing.
D Wear approved ear protection if noise level is
high.

CYLINDERS can explode if damaged.
Shielding gas cylinders contain gas under high
pressure. If damaged, a cylinder can explode. Since
gas cylinders are normally part of the welding
process, be sure to treat them carefully.
D Protect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.
D Install cylinders in an upright position by securing to a stationary
support or cylinder rack to prevent falling or tipping.
D Keep cylinders away from any welding or other electrical circuits.
D Never drape a welding torch over a gas cylinder.
D Never allow a welding electrode to touch any cylinder.
D Never weld on a pressurized cylinder – explosion will result.
D Use only correct shielding gas cylinders, regulators, hoses, and fittings designed for the specific application; maintain them and
associated parts in good condition.
D Turn face away from valve outlet when opening cylinder valve.
D Keep protective cap in place over valve except when cylinder is in
use or connected for use.
D Read and follow instructions on compressed gas cylinders,
associated equipment, and CGA publication P-1 listed in Safety
Standards.

1-3. Additional Symbols For Installation, Operation, And Maintenance
FIRE OR EXPLOSION hazard.

MOVING PARTS can cause injury.

D Do not install or place unit on, over, or near
combustible surfaces.
D Do not install unit near flammables.
D Do not overload building wiring – be sure power supply system is
properly sized, rated, and protected to handle this unit.

D Keep away from moving parts such as fans.
D Keep all doors, panels, covers, and guards
closed and securely in place.

FALLING UNIT can cause injury.

H.F. RADIATION can cause interference.

D Use lifting eye to lift unit only, NOT running
gear, gas cylinders, or any other accessories.
D Use equipment of adequate capacity to lift and
support unit.
D If using lift forks to move unit, be sure forks are
long enough to extend beyond opposite side of
unit.

D

OVERUSE can cause OVERHEATING

D

D Allow cooling period; follow rated duty cycle.
D Reduce current or reduce duty cycle before
starting to weld again.
D Do not block or filter airflow to unit.

D
D

D High-frequency (H.F.) can interfere with radio
navigation, safety services, computers, and
communications equipment.
D Have only qualified persons familiar with
electronic equipment perform this installation.
The user is responsible for having a qualified electrician promptly correct any interference problem resulting from the installation.
If notified by the FCC about interference, stop using the
equipment at once.
Have the installation regularly checked and maintained.
Keep high-frequency source doors and panels tightly shut, keep
spark gaps at correct setting, and use grounding and shielding to
minimize the possibility of interference.

STATIC (ESD) can damage PC boards.
D Put on grounded wrist strap BEFORE handling
boards or parts.
D Use proper static-proof bags and boxes to
store, move, or ship PC boards.

ARC WELDING can cause interference.

MOVING PARTS can cause injury.
D Keep away from moving parts.
D Keep away from pinch points such as drive
rolls.

D
D

WELDING WIRE can cause injury.
D Do not press gun trigger until instructed to do
so.
D Do not point gun toward any part of the body,
other people, or any metal when threading
welding wire.

D
D

D Electromagnetic energy can interfere with
sensitive electronic equipment such as
computers and computer-driven equipment
such as robots.
D Be sure all equipment in the welding area is
electromagnetically compatible.
To reduce possible interference, keep weld cables as short as
possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment.
Be sure this welding machine is installed and grounded
according to this manual.
If interference still occurs, the user must take extra measures
such as moving the welding machine, using shielded cables,
using line filters, or shielding the work area.

1-4. Principal Safety Standards
Safety in Welding and Cutting, ANSI Standard Z49.1, from American
Welding Society, 550 N.W. LeJeune Rd, Miami FL 33126
Safety and Health Standards, OSHA 29 CFR 1910, from Superintendent of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practices for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, American
Welding Society Standard AWS F4.1, from American Welding Society,
550 N.W. LeJeune Rd, Miami, FL 33126
National Electrical Code, NFPA Standard 70, from National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
from Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Code for Safety in Welding and Cutting, CSA Standard W117.2, from
Canadian Standards Association, Standards Sales, 178 Rexdale
Boulevard, Rexdale, Ontario, Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face
Protection, ANSI Standard Z87.1, from American National Standards
Institute, 1430 Broadway, New York, NY 10018.
Cutting And Welding Processes, NFPA Standard 51B, from National
Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

OM-198 683 Page 3

1-5. EMF Information
Considerations About Welding And The Effects Of Low Frequency
Electric And Magnetic Fields
Welding current, as it flows through welding cables, will cause electromagnetic fields. There has been and still is some concern about such
fields. However, after examining more than 500 studies spanning 17
years of research, a special blue ribbon committee of the National
Research Council concluded that: “The body of evidence, in the
committee’s judgment, has not demonstrated that exposure to powerfrequency electric and magnetic fields is a human-health hazard.”
However, studies are still going forth and evidence continues to be
examined. Until the final conclusions of the research are reached, you
may wish to minimize your exposure to electromagnetic fields when
welding or cutting.
To reduce magnetic fields in the workplace, use the following
procedures:

OM-198 683 Page 4

1. Keep cables close together by twisting or taping them.
2. Arrange cables to one side and away from the operator.
3. Do not coil or drape cables around your body.
4. Keep welding power source and cables as far away from operator as practical.
5. Connect work clamp to workpiece as close to the weld as possible.
About Pacemakers:
Pacemaker wearers consult your doctor first. If cleared by your doctor,
then following the above procedures is recommended.

SECTION 1 – CONSIGNES DE SECURITE – LIRE AVANT
UTILISATION
som _nd_fre 4/98

1-1. Signification des symboles
Signifie Mise en garde ! Soyez vigilant ! Cette procédure
présente des risques de danger ! Ceux-ci sont identifiés
par des symboles adjacents aux directives.
Y Identifie un message de sécurité particulier.

. Signifie NOTA ; n’est pas relatif à la sécurité.

Ce groupe de symboles signifie Mise en garde ! Soyez vigilant ! Il y a des
risques de danger reliés aux CHOCS ÉLECTRIQUES, aux PIÈCES EN
MOUVEMENT et aux PIÈCES CHAUDES. Reportez-vous aux symboles
et aux directives ci-dessous afin de connaître les mesures à prendre pour
éviter tout danger.

1-2. Dangers relatifs au soudage à l’arc
Y Les symboles présentés ci-après sont utilisés tout au long du
présent manuel pour attirer votre attention et identifier les risques
de danger. Lorsque vous voyez un symbole, soyez vigilant et
suivez les directives mentionnées afin d’éviter tout danger. Les
consignes de sécurité présentées ci-après ne font que résumer
l’information contenue dans les normes de sécurité énumérées
à la section 1-4. Veuillez lire et respecter toutes ces normes de
sécurité.
Y L’installation, l’utilisation, l’entretien et les réparations ne doivent être confiés qu’à des personnes qualifiées.
Y Au cours de l’utilisation, tenir toute personne à l’écart et plus particulièrement les enfants.

D N’utiliser qu’un matériel en bon état. Réparer ou remplacer sur-lechamp les pièces endommagées. Entretenir l’appareil conformément
à ce manuel.
D Porter un harnais de sécurité quand on travaille en hauteur.
D Maintenir solidement en place tous les panneaux et capots.
D Fixer le câble de retour de façon à obtenir un bon contact métal-métal
avec la pièce à souder ou la table de travail, le plus près possible de la
soudure.
D

Isoler la pince de masse quand pas mis à la pièce pour éviter le contact
avec tout objet métallique.

UN CHOC ÉLECTRIQUE peut tuer.
Un simple contact avec des pièces électriques peut
provoquer une électrocution ou des blessures graves.
L’électrode et le circuit de soudage sont sous tension
dès que l’appareil est sur ON. Le circuit d’entrée et les
circuits internes de l’appareil sont également sous
tension à ce moment-là. En soudage semi-automatique ou automatique,
le fil, le dévidoir, le logement des galets d’entraînement et les pièces
métalliques en contact avec le fil de soudage sont sous tension. Des
matériels mal installés ou mal mis à la terre présentent un danger.

Il y a DU COURANT CONTINU IMPORTANT dans les
convertisseurs après la suppression de l’alimentation électrique.
D Arrêter les convertisseurs, débrancher le courant électrique, et décharger les condensateurs d’alimentation selon les instructions
indiquées dans la partie entretien avant de toucher les pièces.

D Ne jamais toucher les pièces électriques sous tension.
D Porter des gants et des vêtements de protection secs ne comportant
pas de trous.
D S’isoler de la pièce et de la terre au moyen de tapis ou d’autres
moyens isolants suffisamment grands pour empêcher le contact physique éventuel avec la pièce ou la terre.
D
D
D

Ne pas se servir de source électrique àcourant électrique dans les zones
humides, dans les endroits confinés ou là où on risque de tomber.
Se servir d’une source électrique àcourant électrique UNIQUEMENT si le
procédé de soudage le demande.
Si l’utilisation d’une source électrique àcourant électrique s’avère nécessaire, se servir de la fonction de télécommande si l’appareil en est équipé.

D Couper l’alimentation ou arrêter le moteur avant de procéder à l’installation, à la réparation ou à l’entretien de l’appareil. Déverrouiller
l’alimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de
sécurité).
D Installer et mettre à la terre correctement cet appareil conformément à
son manuel d’utilisation et aux codes nationaux, provinciaux et
municipaux.
D Toujours vérifier la terre du cordon d’alimentation – Vérifier et s’assurer que le fil de terre du cordon d’alimentation est bien raccordé à la
borne de terre du sectionneur ou que la fiche du cordon est raccordée
à une prise correctement mise à la terre.
D En effectuant les raccordements d’entrée fixer d’abord le conducteur
de mise à la terre approprié et contre-vérifier les connexions.
D Vérifier fréquemment le cordon d’alimentation pour voir s’il n’est pas
endommagé ou dénudé – remplacer le cordon immédiatement s’il est
endommagé – un câble dénudé peut provoquer une électrocution.
D Mettre l’appareil hors tension quand on ne l’utilise pas.
D Ne pas utiliser des câbles usés, endommagés, de grosseur insuffisante ou mal épissés.
D Ne pas enrouler les câbles autour du corps.
D Si la pièce soudée doit être mise à la terre, le faire directement avec un
câble distinct.
D Ne pas toucher l’électrode quand on est en contact avec la pièce, la
terre ou une électrode provenant d’une autre machine.

LES FUMÉES ET LES GAZ peuvent
être dangereux.
Le soudage génère des fumées et des gaz. Leur
inhalation peut être dangereux pour votre santé.

D
D
D
D

D

D

D Eloigner votre tête des fumées. Ne pas respirer
les fumées.
A l’intérieur, ventiler la zone et/ou utiliser un échappement au niveau
de l’arc pour l’évacuation des fumées et des gaz de soudage.
Si la ventilation est insuffisante, utiliser un respirateur à alimentation d’air homologué.
Lire les spécifications de sécurité des matériaux (MSDSs) et les
instructions du fabricant concernant les métaux, les consommables, les revêtements, les nettoyants et les dégraisseurs.
Travailler dans un espace fermé seulement s’il est bien ventilé ou en
portant un respirateur à alimentation d’air. Demander toujours à un
surveillant dûment formé de se tenir à proximité. Des fumées et des
gaz de soudage peuvent déplacer l’air et abaisser le niveau d’oxygène provoquant des blessures ou des accidents mortels. S’assurer que l’air de respiration ne présente aucun danger.
Ne pas souder dans des endroits situés à proximité d’opérations de
dégraissage, de nettoyage ou de pulvérisation. La chaleur et les
rayons de l’arc peuvent réagir en présence de vapeurs et former des
gaz hautement toxiques et irritants.
Ne pas souder des métaux munis d’un revêtement, tels que l’acier
galvanisé, plaqué en plomb ou au cadmium à moins que le revêtement n’ait été enlevé dans la zone de soudure, que l’endroit soit bien
ventilé, et si nécessaire, en portant un respirateur à alimentation
d’air. Les revêtements et tous les métaux renfermant ces éléments
peuvent dégager des fumées toxiques en cas de soudage.

OM-198 683 Page 5

LES RAYONS DE L’ARC peuvent provoquer des brûlures dans les yeux et
sur la peau.
Le rayonnement de l’arc du procédé de soudage
génère des rayons visibles et invisibles intenses
(ultraviolets et infrarouges) susceptibles de provoquer
des brûlures dans les yeux et sur la peau. Des étincelles sont projetées
pendant le soudage.

D Porter un casque de soudage muni d’un écran de filtre approprié pour
protéger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 énuméré dans les normes de sécurité).
D Porter des protections approuvés pour les oreilles si le niveau sondre est
trop élevé.

D Utiliser des écrans ou des barrières pour protéger des tiers de l’éclair
et de l’éblouissement; demander aux autres personnes de ne pas regarder l’arc.
D Porter des vêtements de protection constitué dans une matière durable, résistant au feu (cuir ou laine) et une protection des pieds.

LE SOUDAGE peut provoquer un
incendie ou une explosion.
Le soudage effectué sur des conteneurs fermés tels
que des réservoirs, tambours ou des conduites peut
provoquer leur éclatement. Des étincelles peuvent être
projetées de l’arc de soudure. La projection d’étincelles, des pièces chaudes et des équipements chauds peut provoquer des
incendies et des brûlures. Le contact accidentel de l’électrode avec des
objets métalliques peut provoquer des étincelles, une explosion, un
surchauffement ou un incendie. Avant de commencer le soudage, vérifier
et s’assurer que l’endroit ne présente pas de danger.
D Se protéger et d’autres personnes de la projection d’étincelles et de
métal chaud.
D Ne pas souder dans un endroit là où des étincelles peuvent tomber sur
des substances inflammables.
D Déplacer toutes les substances inflammables à une distance de 10,7
m de l’arc de soudage. En cas d’impossibilité les recouvrir soigneusement avec des protections homologués.
D Des étincelles et des matériaux chauds du soudage peuvent facilement passer dans d’autres zones en traversant de petites fissures et
des ouvertures.
D Surveiller tout déclenchement d’incendie et tenir un extincteur à proximité.
D Le soudage effectué sur un plafond, plancher, paroi ou séparation
peut déclencher un incendie de l’autre côté.
D Ne pas effectuer le soudage sur des conteneurs fermés tels que des
réservoirs, tambours, ou conduites, à moins qu’ils n’aient été préparés correctement conformément à AWS F4.1 (voir les normes de
sécurité).
D Brancher le câble sur la pièce le plus près possible de la zone de soudage pour éviter le transport du courant sur une longue distance par
des chemins inconnus éventuels en provoquant des risques d’électrocution et d’incendie.
D Ne pas utiliser le poste de soudage pour dégeler des conduites gelées.
D En cas de non utilisation, enlever la baguette d’électrode du porteélectrode ou couper le fil à la pointe de contact.
D Porter des vêtements de protection dépourvus d’huile tels que des
gants en cuir, une chemise en matériau lourd, des pantalons sans revers, des chaussures hautes et un couvre chef.
D Avant de souder, retirer toute substance combustible de vos poches
telles qu’un allumeur au butane ou des allumettes.

DES PARTICULES VOLANTES
peuvent blesser les yeux.
D Le soudage, l’écaillement, le passage de la pièce
à la brosse en fil de fer, et le meulage génèrent
des étincelles et des particules métalliques volantes. Pendant la période de refroidissement des soudures, elles risquent de projeter du laitier.
D

Porter des lunettes de sécurité avec écrans latéraux ou un écran facial.

OM-198 683 Page 6

LES ACCUMULATIONS DE GAZ risquent de provoquer des blessures ou
même la mort.
D

D

Fermer l’alimentation du gaz protecteur en cas de
non utilisation.
Veiller toujours à bien aérer les espaces confinés ou se servir d’un respirateur d’adduction d’air homologué.

DES PIÈCES CHAUDES peuvent provoquer des brûlures graves.
D Ne pas toucher des parties chaudes à mains nues
D Prévoir une période de refroidissement avant
d’utiliser le pistolet ou la torche.

LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D
D

Porteurs de stimulateur cardiaque, restez à distance.
Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher
des opérations de soudage à l’arc, de gougeage ou
de soudage par points.

LE BRUIT peut affecter l’ouïe.
Le bruit des processus et des équipements peut affecter
l’ouïe.
D

Porter des protections approuvés pour les oreilles si
le niveau sondre est trop élevé.

Si des BOUTEILLES sont endommagées, elles pourront exploser.
Des bouteilles de gaz protecteur contiennent du gaz
sous haute pression. Si une bouteille est endommagée, elle peut exploser. Du fait que les bouteilles de gaz
font normalement partie du procédé de soudage, les
manipuler avec précaution.
D Protéger les bouteilles de gaz comprimé d’une chaleur excessive,
des chocs mécaniques, du laitier, des flammes ouvertes, des étincelles et des arcs.
D Placer les bouteilles debout en les fixant dans un support stationnaire ou dans un porte-bouteilles pour les empêcher de tomber ou de
se renverser.
D Tenir les bouteilles éloignées des circuits de soudage ou autres circuits électriques.
D Ne jamais placer une torche de soudage sur une bouteille à gaz.
D Une électrode de soudage ne doit jamais entrer en contact avec une
bouteille.
D Ne jamais souder une bouteille pressurisée – risque d’explosion.
D Utiliser seulement des bouteilles de gaz protecteur, régulateurs,
tuyaux et raccords convenables pour cette application spécifique;
les maintenir ainsi que les éléments associés en bon état.
D Ne pas tenir la tête en face de la sortie en ouvrant la soupape de la
bouteille.
D Maintenir le chapeau de protection sur la soupape, sauf en cas d’utilisation ou de branchement de la bouteille.
D Lire et suivre les instructions concernant les bouteilles de gaz comprimé, les équipements associés et les publications P-1 CGA énumérées dans les normes de sécurité.

1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement
et la maintenance
Risque D’INCENDIE OU
D’EXPLOSION.

DES ORGANES MOBILES peuvent
provoquer des blessures.

D Ne pas placer l’appareil sur, au-dessus ou à proximité de surfaces infllammables.

D Rester à l’écart des organes mobiles comme le
ventilateur.
D Maintenir fermés et fixement en place les portes,
panneaux, recouvrements et dispositifs de
protection.

D Ne pas installer l’appareil à proximité de produits inflammables
D Ne pas surcharger l’installation électrique – s”assurer que l’alimentation est correctement dimensionné et protégé avant de mettre
l’appareil en service.

LE RAYONNEMENT HAUTE FRÉQUENCE (H.F.) risque de provoquer
des interférences.

LA CHUTE DE L’APPAREIL peut
blesser.
D Utiliser l’anneau de levage uniquement pour soulever l’appareil, NON PAS les chariot, les bouteilles de gaz ou tout autre accessoire.
D Utiliser un engin d’une capacité appropriée pour
soulever l’appareil.
D En utilisant des fourches de levage pour déplacer l’unité, s’assurer
que les fourches sont suffisamment longues pour dépasser du côté
opposé de l’appareil.

L’EMPLOI EXCESSIF peut
SURCHAUFFER L’ÉQUIPEMENT.

D
D
D
D
D

D Prévoir une période de refroidissement, respecter le cycle opératoire nominal.
D Réduire le courant ou le cycle opératoire avant de
recommancer le soudage.

LE SOUDAGE À L’ARC risque de
provoquer des interférences.

D Ne pas obstruer les passages d’air du poste.

LES CHARGES ÉLECTROSTATIQUES peuvent endommager les circuits imprimés.
D Établir la connexion avec la barrette de terre
avant de manipuler des cartes ou des pièces.
D Utiliser des pochettes et des boîtes antistatiques
pour stocker, déplacer ou expédier des cartes de
circuits imprimes.

DES ORGANES MOBILES peuvent
provoquer des blessures.
D Ne pas s’approcher des organes mobiles.
D Ne pas s’approcher des points de coincement
tels que des rouleaux de commande.

LES FILS DE SOUDAGE peuvent provoquer des blessures.
D Ne pas appuyer sur la gachette avant d’en avoir
reçu l’instruction.
D Ne pas diriger le pistolet vers soi, d’autres personnes ou toute pièce mécanique en engageant le fil
de soudage.

D Le rayonnement haute frequence peut provoquer
des interférences avec les équipements de radio–navigation et de communication, les services
de sécurité et les ordinateurs.
Demander seulement à des personnes qualifiées familiarisées
avec des équipements électroniques de faire fonctionner l’installation.
L’utilisateur est tenu de faire corriger rapidement par un électricien
qualifié les interférences résultant de l’installation.
Si le FCC signale des interférences, arrêter immédiatement l’appareil.
Effectuer régulièrement le contrôle et l’entretien de l’installation.
Maintenir soigneusement fermés les portes et les panneaux des
sources de haute fréquence, maintenir les éclateurs à une distance
correcte et utiliser une terre et et un blindage pour réduire les interférences éventuelles.

D
D
D
D
D

D L’énergie électromagnétique risque de provoquer
des interférences pour l’équipement électronique
sensible tel que les ordinateurs et l’équipement
commandé par ordinateur tel que les robots.
Veiller à ce que tout l’équipement de la zone de soudage soit compatible électromagnétiquement.
Pour réduire la possibilité d’interférence, maintenir les câbles de
soudage aussi courts que possible, les grouper, et les poser aussi
bas que possible (ex. par terre).
Veiller à souder à une distance de 100 mètres de tout équipement
électronique sensible.
Veiller à ce que ce poste de soudage soit posé et mis à la terre
conformément à ce mode d’emploi.
En cas d’interférences après avoir pris les mesures précédentes, il
incombe à l’utilisateur de prendre des mesures supplémentaires telles que le déplacement du poste, l’utilisation de câbles blindés, l’utilisation de filtres de ligne ou la pose de protecteurs dans la zone de
travail.

LES CHAMPS MAGNÉTIQUES peuvent
affecter les stimulateurs cardiaques.
D Porteurs de stimulateur cardiaque, restez à distance.
D Les porteurs d’un stimulateur cardiaque doivent
d’abord consulter leur médecin avant de s’approcher des opérations de soudage à l’arc, de gougeage ou de soudage par points.

OM-198 683 Page 7

1-4. Principales normes de sécurité
Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL 33126
Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.
Recommended Safe Practice for the Preparation for Welding and Cutting of Containers That Have Held Hazardous Substances, norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126
National Electrical Code, NFPA Standard 70, de la National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.
Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.
Safe Practices For Occupation And Educational Eye And Face Protection, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.
Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.

1-5. Information sur les champs électromagnétiques
Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence

Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :
1

Le courant de soudage, pendant son passage dans les câbles de soudage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir examiné plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Research Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les conclusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnétiques pendant le soudage ou le coupage.

OM-198 683 Page 8

2
3
4
5

Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.
Mettre tous les câbles du côté opposé de l’opérateur.
Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.
Garder le poste de soudage et les câbles le plus loin possible de
vous.
Relier la pince de masse le plus près possible de la zone de
soudure.

Consignes relatives aux stimulateurs cardiaques :
Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.

SECTION 2 – INSTALLATION
2-1. Specifications
Max. OpenCircuit
Voltage

Rated Output
250 A at 28 VDC,
40% Duty Cycle

200 A at 28 VDC,
60% Duty Cycle

Amps Input at Rated Output, 50 or 60 Hz, Single-Phase
200 (208) V

230 V

400 V

460 V

575 V

KVA

KW

48
2.3*

42
2*

24
1.2*

21
1*

17
0.8*

9.8
0.46*

7.5
0.13*

38

Wire Type and Diameter
Solid Steel

Stainless Steel

Flux Cored

.023 – .045 in
(0.6 – 1.2 mm)

.023 – .035 in
(0.6 – 0.9 mm)

.030 – .045 in
(0.8 – 1.2 mm)

Wire Feed Speed

Dimensions

Net Weight

25–700 IPM
(.65–17.8 m/min)

H: 37 in (940 mm)
W: 19 in (483 mm)
D: 30-1/4 in (768 mm)

212 lb
(96 kg)

* While idling

Operating Temperature Range – –20C to +40C

Storage Temperature Range – -30C to + 50C

2-2. Welding Power Source Duty Cycle And Overheating
Duty Cycle is percentage of 10 minutes that unit can weld at rated load
without overheating.
If unit overheats, thermostat(s)
opens, output stops, and cooling
fan runs. Wait fifteen minutes for
unit to cool. Reduce amperage or
voltage, or duty cycle before
welding.
Y Exceeding duty cycle can
damage unit and void
warranty.

60% Duty Cycle At 200 Amperes

6 Minutes Welding

40% Duty Cycle At 250 Amperes

4 Minutes Resting

4 Minutes Welding

6 Minutes Resting

Overheating

A or V

0

15

OR
Reduce Duty Cycle

Minutes
duty1 4/95 – 150 215-A

OM-198 683 Page 9

2-3. Welding Gun Duty Cycle And Overheating

CAUTION
WELDING LONGER THAN RATED DUTY CYCLE can damage gun and void warranty.

•
•

Do not weld at rated load longer than shown below.
Using gasless flux cored wire reduces gun duty cycle.
Definition

warn7.1 8/93

.023 To .045 in (0.6 To 1.1 mm)
Hard Or Flux Cored Wires

0
10
Minutes

.023 To .045 in (0.6 To 1.1 mm) Hard Or Flux Cored Wires
60% Duty Cycle At 300 Amperes
Using CO2

100% Duty Cycle At 200 Amperes
Using CO2

60% Duty Cycle At 200 Amperes
Using Mixed Gases

100% Duty Cycle At 150 Amperes
Using Mixed Gases
Duty Cycle is percentage of 10
minutes that gun can weld at
rated load without overheating.

6 Minutes Welding

Continuous Welding

4 Minutes Resting
SB1.1 8/93

2-4. Volt-Ampere Curves
1
1
35
30

Normal Volt-Ampere Curves

The volt-ampere curves show the
normal minimum and maximum
voltage and amperage output capabilities of the welding power source.
Curves of other settings fall between the curves shown.

VOLTS

25
20
15
10
5
0

0

100

200

300

400

AMPERES

ssb1.1 10/91 – 196 844 / S-0700

OM-198 683 Page 10

2-5. Installing Work Clamp
1
2

Work Cable
Boot

Slide boot onto work cable. Route
cable out front panel opening from
inside.
3
4

4
5
5

Negative (–) Output Terminal

Connect cable to terminal and
cover connection with boot.
Hardware
Work Clamp

Route cable through clamp handle
and secure as shown.
Close door.

1
2
3

Tools Needed:
1/2, 3/4 in
802 474-A

2-6. Installing Welding Gun
1
2
3

Drive Assembly
Gun Securing Knob
Gun End

Loosen securing knob. Insert gun
end through opening until it bottoms
against drive assembly (make sure
gun end does not touch drive rolls).
Tighten knob.

1

4

Gun Trigger Plug

Insert plug into receptacle, and
tighten threaded collar.

3

Close door.

4
2
Ref. 802 064-A

2-7. Connecting Olympic 30A Gun
The Olympic 30A welding gun connects directly to the 10-pin receptacle on the front of the welding power source – no
adapter required. NOTE: Two welding guns may be connected to the welding power source at the same time, but only
one welding gun may be in use at any one time. If the triggers of both welding guns are pulled at the same time, the weld
output and wirefeed motor are disabled.
OM-198 683 Page 11

2-8. Setting Gun Polarity For Wire Type
1

Changing Polarity

Polarity Changeover Label
Information

Always read and follow manufacture’s recommended polarity.

Wire Drive
Assembly Lead

Work Clamp Lead

1
D
D

+

Positive Terminal

-

Negative Terminal

Shown as shipped – Electrode Positive (DCEP): For
solid steel, stainless steel, aluminum, or flux core with
gas wires (GMAW).
Electrode Negative (DCEN): Reverse lead connections
at terminals from that shown above for gasless flux core
wires (FCAW). Drive assembly becomes negative.

3/4, 11/16 in
Ref. 190 821-A

2-9. Installing Gas Supply
Obtain gas cylinder and chain to
running gear, wall, or other stationary support so cylinder cannot fall
and break off valve.

1

2

1

Cap

2

Cylinder Valve

Remove cap, stand to side of
valve, and open valve slightly. Gas
flow blows dust and dirt from valve.
Close valve.

3

3

Cylinder

4

Regulator/Flowmeter

Install so face is vertical.

4

5

Regulator/Flowmeter Gas
Hose Connection

6

Welding Power Source Gas
Hose Connection

Argon Gas
1
OR
2
5

7

Connect customer supplied gas
hose between regulator/flowmeter
gas hose connection, and fitting on
rear of welding power source.
7

3
8

9
CO2 Gas

Flow Adjust

Typical flow rate is 20 cfh (cubic
feet per hour). Check wire manufacturer’s recommended flow
rate.
8

CO2 Adapter (Customer Supplied)

9

O-Ring (Customer Supplied)

Install adapter with O-ring between
regulator/flowmeter and CO2
cylinder.
6
Tools Needed:
1-1/8, 5/8 in
Ref. ST-148 265-B / ST-802 028

OM-198 683 Page 12

2-10. Installing Wire Spool and Adjusting Hub Tension
Use compression spring with
8 in (200 mm) spools.

When a slight force is needed to turn spool, tension is set.

Tools Needed:

15/16 in
ST-072573-B

2-11. Positioning Jumper Links
230 VOLTS

Check input voltage available at
site.
1

Jumper Links Access Door

Open door.

3
200 VOLTS

460 VOLTS

2

Jumper Link Label

Check label – only one is on unit.
3
230 VOLTS

575 VOLTS

Input Voltage Jumper Links

Move jumper links to match input
voltage.
Close and secure access door.

S-153 980

S-144 916-A

2
1

Tools Needed:

3/8 in

802 476-A

OM-198 683 Page 13

2-12. Electrical Service Guide
Input Voltage

200

230

400

460

575

Input Amperes At Rated Output

48

42

24

21

17

Circuit Breaker 1, Time-Delay 2

60

50

30

25

20

3

70

60

35

30

25

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

Normal Operating
Min Input Conductor Size In AWG/Kcmil
Max Recommended Input Conductor Length In Feet (Meters)
Min Grounding Conductor Size In AWG/Kcmil

8

8

12

12

14

96
(29)

127
(39)

156
(47)

206
(63)

209
(64)

8

10

12

12

14

Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a Time Delay Fuse.
2 “Time-Delay” fuses are UL class “RK5” .
3 “Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
Y Caution: Failure to follow these fuse and circuit breaker recommendations could create an electric shock or fire hazard.

2-13. Selecting A Location And Connecting Input Power
1

Rating Label

Supply correct input power.
2
3

Plug (NEMA Type 6-50P)
Receptacle
(NEMA Type 6-50R)

Connect plug to receptacle.

18 in (457 mm) of
space for airflow
Y Do not move or operate unit
where it could tip.
Y Always connect
grounding conductor first.

4

Input And Grounding
Conductors

Connect directly to line disconnect
device if hard wiring is required.
5

Line Disconnect Device

See Section 2-12.

= GND/PE

Y Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.

5

L1
L2

4
2

1

3
L2

L1

230 VAC, 1
802 477

OM-198 683 Page 14

2-14. Threading Welding Wire
1
2
3
4
5
6
7

4

7

Wire Spool
Welding Wire
Inlet Wire Guide
Pressure Adjustment Knob
Drive Roll
Outlet Wire Guide
Gun Conduit Cable

Lay gun cable out straight.

Tools Needed:

1

2

3

5

6

. Hold wire tightly to keep it
from unraveling.

6 in
(150 mm)
Open pressure assembly.

Pull and hold wire; cut off end.

. Use pressure indicator

Tighten

scale to set a desired
drive roll pressure.

1
2
3
4

Close and tighten pressure
assembly, and let go of wire.

Push wire thru guides into gun;
continue to hold wire.

Pressure
Indicator
Scale

Remove gun nozzle and contact tip.

Turn On.

Tighten

WOOD
Press gun trigger until wire
comes out of gun. Reinstall
contact tip and nozzle

1
2
3
4

Feed wire to check drive roll pressure.
Tighten knob enough to prevent slipping.

Cut off wire. Close
and latch door.
Ref. 802 064-A / S-0627-A

OM-198 683 Page 15

2-15. Weld Parameter

OM-198 683 Page 16

V
V
VOL TAGE

WIRE SPEED

196 843

OM-198 683 Page 17

SECTION 3 – OPERATION
3-1. Controls
1

Voltage Control

Turn control clockwise to increase
voltage.
4

2

Wire Speed Control

Turn control clockwise to increase
wire feed speed.

1

3
4
5

Power Switch
Voltmeter
Wire Feed Speed Meter

2

3

5

198 653

OM-198 683 Page 18

3-2. Voltmeter And Wire Feed Speed Meter Operation
1
2

Voltmeter
Wire Feed Speed Meter

Power Up Status

1

Both meters display zeros at unit
power up. After one second, preset
values appear on both meters. The
MIG gun settings (not spool gun)
are always the default at initial
power up of the unit.
Welding Status

2

When either a MIG gun or spool gun
trigger is pressed and a welding arc
is established, the voltmeter
displays actual weld voltage. When
the gun trigger is released and
welding arc extinguished, the
voltmeter displays the last actual
voltage for 5 seconds and then
returns to preset voltage. If welding
resumes before unit displays
preset voltage, actual welding
voltage will appear on the voltmeter.
The wire feed speed meter always
displays preset wire feed speed
(IPM).
Gun Selection
The wire feed speed meter will
display preset wire feed speed
(IPM) for the appropriate gun
selection either MIG or spool gun.
To preset desired wire feed speed,
connect desired gun, press gun
trigger for one second, and release
trigger. The meter preset will be
retained by the meter board until a
different gun is connected and
preset is performed or the unit is
turned off and back on. The MIG
gun settings (not spool gun) are
always the default at initial power up
of the unit.
Error Message
If the rectifier thermostat opens, the
voltmeter will display (H – –) and the
wire feed speed meter will display
(– – –). During this overheated
condition, the unit is inoperative and
the meters retain their display until
the rectifier returns to normal
operating temperature.

OM-198 683 Page 19

SECTION 4 – MAINTENANCE &TROUBLESHOOTING
4-1. Routine Maintenance
. Maintain more often

Y Disconnect power
before maintaining.

during severe conditions.

3 Months
Replace unreadable labels

Repair or replace
cracked weld cable

Clean and tighten weld terminals

6 Months

Blow out or vacuum inside.
OR

Remove drive roll and
carrier. Apply light coat
of oil or grease to drive
motor shaft.

4-2. Circuit Breaker CB1
1

Circuit Breaker CB1

If CB1 opens, wire feeding stops.
2

Circuit Breaker CB2

Overcurrent at pin D of receptacle
RC7 will cause CB2 to open.
1

2

3

Welding Gun

Check gun liner for blockage or
kinks.
4

Wire Drive Assembly

Check for jammed wire, binding
drive gear or misaligned drive rolls.
3

Allow cooling period and reset
breaker. Close door.

4
802 475-A / Ref. 800 797-C

4-3. Unit Overload
Thermostat TP1 in rectifier Z1 protects the unit from damage due to overheating. If TP1 opens, wait several minutes
before trying to weld.
OM-198 683 Page 20

4-4. Replacing Gun Contact Tip
Y Turn Off power.
1
2

Nozzle
Contact Tip

Cut off welding wire at contact tip.
Remove nozzle.
Remove contact tip and install new
contact tip. Reinstall nozzle.

2
1

Tools Needed:

Ref. 800 797-C

4-5. Changing Drive Roll and Wire Inlet Guide
1
2
5
3

Loosen screw. Slide tip as close to
drive rolls as possible without
touching. Tighten screw.
3

2

Securing Screw
Inlet Wire Guide

Anti-Wear Guide

Install guide as shown.
4

Drive Roll

Install correct drive roll for wire size
and type.
5
1

Drive Roll Securing Nut

Turn nut one click to secure drive
roll.

4
Tools Needed:
5/64 in
7/16 in
ST-150 227-D

OM-198 683 Page 21

4-6. Aligning Drive Rolls and Wire Guide
Y Turn Off power.
View is from top of drive rolls looking down with pressure assembly
open.
Correct
3

Incorrect
4

2
1
5

1
2
3
4
5

Drive Roll Securing Nut
Drive Roll
Wire Guide
Welding Wire
Drive Gear

Insert screwdriver, and turn screw
in or out until drive roll groove lines
up with wire guide.
Close pressure roll assembly.

Tools Needed:
Ref. ST-800 412-A

OM-198 683 Page 22

4-7. Cleaning Or Replacing Gun Liner
Tools Needed:
Y Disconnect gun from unit first.
5/16 in, 10 mm

Head Tube

Remove nozzle, contact tip, and
adapter.

5/16 in
10 mm

Remove liner.
Lay gun cable out straight
before installing new liner.

To Reassemble Gun:
Blow out gun casing.

Install and tighten new liner.
Cut liner off 3/4 in (20 mm) (3/8 in
[9.5 mm] for aluminum) from head
tube.
Install adapter, contact tip, and
nozzle.

Ref. ST-800 797-C

OM-198 683 Page 23

4-8. Replacing Switch And/Or Head Tube
Y Disconnect gun first.

1

Remove handle
locking nut.

3

2

4

Slide handle.

Remove switch housing. Note: If installing new
switch, push switch lead connectors onto terminal of
new switch (polarity is not important). Install switch
back into handle, and secure with handle locking nut.
If replacing head tube, continue to end of figure.

Secure head
tube in vice.

5

6

Loosen jam nut. Remove
from vice and turn head
tube out by hand.

Install existing shock washer onto
new head tube. Hand-tighten head
tube into connector cable.

8

7

Place head tube in vice and tighten
until nuts are tight.

Remove from vice. Reposition
handle and install switch housing.
Secure with handle locking nut.

Tools Needed:
3/4 in

Ref. ST-800 795-C

OM-198 683 Page 24

4-9. Troubleshooting

Trouble

Remedy

No weld output; wire does not feed.

Be sure line disconnect switch is On (see Section 2-13).
Replace building line fuse or reset circuit breaker if open (see Section 2-13).
Reset circuit breaker CB1 (see Section 4-2).
Secure gun trigger connections (see Section 2-6).
Have Factory Authorized Service Agent check Power switch.
Have Factory Authorized Service Agent check all board connections and main control board.
H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an overheated condition (see Section 3-2).

No weld output; wire feeds.

Thermostat TP1 open (overheating). Allow fan to run; the thermostat will close when the unit has cooled
(see Section 2-2).
Connect work clamp to get good metal to metal contact.
Replace contact tip (see Section 4-4).
An overload condition occurred. Release gun trigger (see Section 4-3).
Have Factory Authorized Service Agent check main control board and main rectifier.

Low weld output.

Connect unit to proper input voltage or check for low line voltage (see Section 2-13).
Check input voltage jumper links and correct position if necessary (see Section 2-11).
Have Factory Authorized Service Agent check main control board.

Fan motor does not run.

Have Factory Authorized Service Agent check fan-on-demand circuit.

Low, high, or erratic wire speed.

Readjust front panel settings (see Section 3-1).
Change to correct size drive rolls (see Section 4-5).
Readjust drive roll pressure (see Section 2-14).
Replace inlet guide, contact tip, and/or liner if necessary (see Sections 4-4, and 4-7).
Check position of input jumper links (see Section 2-11).
Have Factory Authorized Service Agent check main control board.

No wire feed.

Reset circuit breaker CB1 (see Section 4-2).
Turn Wire Speed control to higher setting (see Section 3-1).
Clear obstruction in gun contact tip or liner (see Sections 4-4, and 4-7).
Readjust drive roll pressure (see Section 2-14).
Change to correct size drive rolls (see Section 4-5).
Rethread welding wire (see Section 2-14).
Check gun trigger and leads. Repair or replace gun if necessary.
Have Factory Authorized Service Agent check main control board.
H – – message appears on voltmeter display to indicate thermostat TP1 is open and unit is in an overheated condition (see Section 3-2).

OM-198 683 Page 25

Notes

OM-198 683 Page 26

SECTION 5 – ELECTRICAL DIAGRAM

197 699-D

Figure 5-1. Circuit Diagram
OM-198 683 Page 27

SECTION 6 – PARTS LIST
. Hardware is common and

not available unless listed.

802 059-B

Figure 6-1. Main Assembly
OM–198 683 Page 28

Item
No.

Dia.
Mkgs.

Part
No.

Description

Quantity

Figure 6-1. Main Assembly
. . . 1 . . . . . . . . . . . . Fig 6-2
. . . 2 . . . . Z1 . . . 199 159
. . . 3 . . . . . . . . . . . . Fig 6-6
. . . 4 . . . . . . . . . . . 146 165
. . . 5 . . . . . . . . . . . 089 899
. . . 6 . . . . . . . . . . . 146 167
. . . . . . . . . . . . . . . . . 198 079
. . . 7 . . . . . . . . . . . 134 464
. . . 8 . . . . . . . . . +170 513
. . . 9 . . . . . . . . . . . 188 911
. . . 9 . . . . . . . . . . . 187 255
. . . 10 . . . . . . . . . . . 146 161
. . . 11 . . . . . . . . . . . 186 758
. . . 12 . . . . . . . . . . . 052 692
. . . . . . . . . . . . . . . . . 121 614
. . . 13 . . . . . . . . . . . 197 703
. . . . . . . . . SR1 . . . 197 698
. . . . . . . . . SR2 . . . 196 754
. . . . . . . C1,2,3,4 . 031 689
. . . . . . . . . TP1 . . . 154 243
. . . . . . . . . TP2 . . . 154 244
. . . . . . . . . . . . . . . . . 143 852
. . . . . . . . . . . . . . . . . 198 232
. . . . . . . . PLG3 . . 115 094
. . . . . . . . PLG7 . . 115 091
. . . 14 . . . . . . . . . . . 008 999
. . . 15 . . . . . . . . . . . . Fig 6-4
. . . 16 . . . . . . . . . . . 169 596
. . . 17 . . . . . . . . . . . 150 387
. . . 18 . . . . T1 . . . 196 795
. . . 18 . . . . T1 . . . 196 864
. . . 18 . . . . T1 . . . 196 988
. . . . . . . . . TP3 . . . 121 497
. . . 19 . . PLG2 . . 008 072
. . . . . . . . PLG1 . . 088 073
. . . . . . . . . . . . . . . . . 192 121
. . . . . . . . . . . . . . . . . 144 108
. . . . . . . . . . . . . . . . . 130 750
. . . . . . . . . . . . . . . . . 600 318

. . . BAFFLE, center w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . STABILIZER, dual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . PANEL, rear w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . PANEL, side LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . LATCH, slide flush mtg hole 1.000 wide x 1.500 lg . . . . . . . . . . . . . . . . . . . . . . 2
. . . PANEL, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . LABEL, parameters/consumables/polarity/warning . . . . . . . . . . . . . . . . . . . . . . 1
. . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . WRAPPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CABLE, pwr 250v 6-50p 8-10ga 3/c 12ft for 200/230 . . . . . . . . . . . . . . . . . . . . 1
. . . CABLE, pwr 250v t tng 8-10ga 3/c 12ft for 230/460/575 or 230/400 . . . . . . . 1
. . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . WHEEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . AXLE, running gear (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . RING, retaining ext .750 shaft x .085grv depth . . . . . . . . . . . . . . . . . . . . . . . 2
. . . RECTIFIER, SCR main (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . THYRISTOR, SCR module 300A 400V common anode (large) . . . . . . . . . 1
. . . . THYRISTOR, SCR module 95A 400V dual (small) . . . . . . . . . . . . . . . . . . . . 1
. . . . CAPACITOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . . THERMOSTAT, NC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . THERMOSTAT, NO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . FOOT. mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . FOOT, mtg rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . HOUSING PLUG & SKTS (4 position) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . HOUSING PLUG & SKTS (10 position) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CASTER, plstc swvl 4 in dia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . PANEL, front w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . GUN, 12ft .030-.035 wire (Fig 6-3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . BAFFLE, air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . TRANSFORMER, pwr main (200/230) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . TRANSFORMER, pwr main (230/460/575) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . TRANSFORMER, pwr main (230/400) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . THERMOSTAT, NO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING RECEPTACLE & SOCKETS (harness) . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING RECEPTACLE & SOCKETS (xfmr) . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . REGULATOR/FLOWMETER, 10-50 CFH Argon/CO2 . . . . . . . . . . . . . . . . . . . 1
. . . HOSE, gas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CLAMP, ground 350A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CABLE, weld cop strd No. 3 (order by ft) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10ft

+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-198 683 Page 29

. Hardware is common and

not available unless listed.

802 060-C

Figure 6-2. Baffle, Center w/Components

OM–198 683 Page 30

Item
No.

Dia.
Mkgs.

Part
No.

Description

Quantity

Figure 6-2. Baffle, Center w/Components (Fig 6-1 Item 1)
. . . 1 . . . . . . . . . . . 058 427
. . . 2 . . . . . . . . . . . 085 980
. . . 3 . . . . . . . . . . . 605 941
. . . 4 . . . . . . . . . . . 186 437
. . . 5 . . . . . . . . . . . 057 971
. . . 6 . . . . . . . . . . . 057 745
. . . 7 . . . . . . . . . . . 186 435
. . . 8 . . . . . . . . . . . 186 436
. . . 9 . . . . . . . . . . . 177 307
. . . 10 . . . . . . . . . . . 196 797
. . . 11 . . . . . . . . . . . 186 998
. . . 12 . . . . . . . . . . . 082 902
. . . 13 . . . . . . . . . . . 185 643
. . . . . . . . . . . . . . . . . 083 147
. . . 14 . . . . C5 . . . 184 584
. . . . . . . . . . . . . . . . . 187 752
. . . 15 . . . CR1 . . . 006 393
. . . . . . . . . . . . . . . . . 144 425
. . . 16 . . . PC1 . . . 196 456
. . . . . . . . PLG3 . . 115 094
. . . . . . . . PLG4 . . 131 052
. . . . . . . . PLG5 . . 131 056
. . . . . . . . PLG6 . . 115 092
. . . . . . . . PLG7 . . 130 203
. . . 17 . . . . R5 . . . 119 998
. . . 18 . . . TE1 . . . 188 910
. . . 18 . . . TE1 . . . 192 907
. . . 19 . . . . . . . . . . . 038 618
. . . 20 . . . CR2 . . . 000 174
. . . . . . . . . . . . . . . . . 189 364
. . . 21 . . . C3,5 . . 128 750
. . . 22 . . . POS . . 097 421
. . . 23 . . . NEG . . 097 416
. . . 24 . CB1,CB2 180 912
. . . 25 . . . . . . . . . . . 196 318
. . . 26 . . . . . . . . . . . . Fig 6-5
. . . 27 . . . . . . . . . . . 188 917
. . . 28 . . . . . . . . . . . 134 201
. . . 29 . . . . . . . . . . . 197 555
. . . 30 . . . . . . . . . . . 196 894
. . . 31 . . . . . . . . . . . 108 105
. . . 32 . . . C13 . . . 186 311
. . . 33 . . . . . . . . . . . 196 800

. . . RING, retaining spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . NUT, stl hex full .625-11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . WASHER, flat stl .640 ID x 1.000 OD x 14ga thk . . . . . . . . . . . . . . . . . . . . . . . 1
. . . SPRING, cprsn .845 OD x .110 wire x 1.500 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . WASHER, flat stl keyed 1.500dia x .125thk . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . SPRING, cprsn 2.430 OD x .090 wire x 2.500 . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HUB, spool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . WASHER, brake . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . REEL, support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . BAFFLE, center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CAPACITOR ASSEMBLY KIT, (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . STRIP, mtg center capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . . STRIP, mtg capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . . GROMMET, scr No. 8/10 panel hole .312sq .500 high . . . . . . . . . . . . . . . . . 6
. . . . CAPACITOR, elctlt 15000uf 45VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
. . . . INSULATOR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . RELAY, 24VAC DPDT 10A/120VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . VARISTOR, 430V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CIRCUIT CARD, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING RECEPTACLE & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING RECEPTACLE & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . HOUSING PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . RESISTOR, WW fxd 300W 5 ohm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . TERMINAL ASSEMBLY, pri 1ph double voltage (200/230 or 230/400) . . . . . 1
. . . TERMINAL ASSEMBLY, pri 1ph triple voltage (230/460/575) . . . . . . . . . . . . 1
. . . LINK, jumper term bd pri . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . as req.
. . . RELAY, 24VAC 3PDT 10A/120VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . RESISTOR, w/terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . TERMINAL, pwr output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . TERMINAL, pwr output black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CIRCUIT BREAKER, man reset 1P 5A 250VAC . . . . . . . . . . . . . . . . . . . . . . . . 2
. . . COVER, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . WIRE DRIVE & GEARS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . DOOR, access changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . STAND-OFF SUPPORT, PC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
. . . TOOL TRAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . COVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CLAMP, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . CAPACITOR, electlt 91000uf 35VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
. . . BRACKET, mtg capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-198 683 Page 31

16

12

11

9

14

13

15

12

11

10

9
8

17

7
6
5
4
3
2
1

Ref. 800 792-B

Figure 6-3. M-25 Gun

OM–198 683 Page 32

Item
No.

Part
No.

Description

Quantity

Figure 6-3. M-25 Gun (Fig 6-1 Item 16 )
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...

1
1
1
1
1
2
2
2
2
3
4
5
6
7
8
9
10
11
12
13
14
15
15
15
16
17

. . . . . 200 258
. . . ♦169 724
. . . ♦169 725
. . . ♦169 726
. . . ♦169 727
. . . ♦087 299
. . . ♦000 067
. . . ♦000 068
. . . ♦000 069
. . . . . 169 728
. . . . . 169 729
. . . . . 170 467
. . . . . 170 468
. . . . . 169 730
. . . . . 169 731
. . . . . 169 738
. . . . . 194 523
. . . . . 169 737
. . . . . 169 741
. . . . . 180 433
. . . . . 079 974
. . . ♦194 010
. . . ♦194 011
. . . ♦194 012
. . . . . 079 975
. . . . . 196 255

. . NOZZLE, slip type .500 orf flush . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NOZZLE, slip type .500 orf .125 recess
. . NOZZLE, slip type .625 orf .125 recess
. . NOZZLE, slip type .625 orf flush
. . NOZZLE, slip type .625 orf .125 stickout
. . TIP, contact scr .023 wire x 1.125
. . TIP, contact scr .030 wire x 1.125
. . TIP, contact scr .035 wire x 1.125
. . TIP, contact scr .045 wire x 1.125
. . ADAPTER, contact tip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . ADAPTER, nozzle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . RING, retaining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . O-RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . WASHER, shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . TUBE, head . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, locking handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . NUT, jam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . STRAIN RELIEF, cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . CORD, trigger assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . O-RING, .500 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . LINER, monocoil .023/.025 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . .
. . LINER, monocoil .030/.035 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . .
. . LINER, monocoil .035/.045 wire x 15ft (consisting of) . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . O-RING, .187 ID x .103CS rbr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . SWITCH, trigger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

1
1
1
1
1
1
2
1
2
2
1
2
1
1
1
1
1

♦OPTIONAL
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM-198 683 Page 33

Item
No.

Dia.
Mkgs.

Part
No.

Description

Quantity

Figure 6-4. Panel, Front w/Components (Fig 6-1 Item 15)
. . . 1 . . . . . . . . . . . . +196 798
. . . . . . . . . . . . . . . . . . . 198 653
. . . 2 . . . . . . . . . . . . . 196 399
. . . . . . . . PLG10 . . . 130 203
. . . . . . . . . PLG11 . . . 131 203
. . . . . . . . PLG12 . . . 131 204
. . . 3 . . . . . . . . . . . . . 134 201
. . . 4 . . . . . . . . . . . . . 196 801
. . . 5 . C9,10,18,
. . . . . . . . . 19,20 . . . 136 735
. . . 6 . . . R2,3 . . . . 035 897
. . . . . . . . . . . . . . . . . . . 131 052
. . . 7 . . . . . . . . . . . . . 186 473
. . . 8 . . . . S1 . . . . . 128 755
. . . 9 . . . . RC1 . . . . 048 282
. . . 10 . . . . RC7 . . . . 190 363
. . . 11 . . . . . . . . . . . . . 189 810
. . . 12 . . . . . . . . . . . . . 038 502
. . . 13 . . . . . . . . . . . . . 186 472
. . . 14 . . . . . . . . . . . . . 193 632
. . . 15 . . . . . . . . . . . . . 097 924

..
..
..
..
..
..
..
..

PANEL, front control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LABEL, nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT CARD ASSY, display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PLUG w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PLUG w/PINS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PLUG w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STANDOFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BRACKET, mtg display board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1
4
1

..
..
..
..
..
..
..
..
..
..
..
..

CAPACITOR, cer disc .1uf 500VDC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POTENTIOMETER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
HOUSING RECEPTACLE & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SWITCH, tgl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RECEPTACLE w/SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PANEL, logo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable Tie, . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PANEL, louver (Order Item 9, Cable Tie when ordering louver panel) . . .
NUT, 375-16 .56 hex .34H stl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KNOB, pointer 1.625dia x .250 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
2
1
1
1
1
1
1
1
1
2
2

. Hardware is common and

not available unless listed.

802 087-C

Figure 6-4. Panel, Front w/Components
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.

OM–198 683 Page 34

Item
No.

Dia.
Mkgs.

Part
No.

Description

Quantity

Figure 6-5. Wire Drive And Gears (Fig 6-2 Item 26)
. . . 1 . . . . . . . . . . . 602 009
. . . 2 . . . . . . . . . . . 172 075
. . . 3 . . . . . . . . . . . 166 072
. . . 4 . . . . . . . . . . . 010 224
. . . 5 . . . . . . . . . . . 182 788
. . . 6 . . . . . . . . . . . 085 242
. . . 7 . . . . . . . . . . . 196 896
. . . 8 . . . . . . . . . . . 196 897
. . . 9 . . . . . . . . . . . 196 895
. . . 10 . . . . . . . . . . . 166 071
. . . 11 . . . . . . . . . . . 079 634
. . . 12 . . . . . . . . . . . 151 828
. . . 13 . . . . . . . . . . . 173 616
. . . 14 . . . PM . . . 173 435
. . . . . . . . . . . . . . . . . 193 633
. . . . . . . . . . . . . . . . . 193 634
. . . . . . . . . . . . . . . . . 193 635
. . . 15 . . . . . . . . . . . 079 633
. . . 16 . . . . . . . . . . . 601 966
. . . 18 . . . . . . . . . . . 604 538
. . . 19 . . . . . . . . . . . 124 778
. . . 20 . . . . . . . . . . . 173 619
. . . 21 . . . . . . . . . . . 174 609
. . . 22 . . . . . . . . . . . 174 610
. . . 23 . . . . . . . . . . . 192 029
. . . 24 . . . . . . . . . . . 173 620
. . . 25 . . . . . . . . . . . 602 243
. . . 26 . . . . . . . . . . . 602 213
. . . . . . . . . . . . . . . . *045 233

. . . SCREW, .250-20 x 1.25 soc hd gr 8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . CARRIER, drive roll w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . SPACER, gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . PIN, spring CS .187 x 1.000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . HOUSING, adapter gun/feeder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . FASTENER, pinned . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . CUP, spring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . SPRING, cprsn .695 OD x .095 wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . KNOB, tension adj . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . LEVER, mtg pressure gear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . PIN, hinge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . PIN, cotter hair .054 x .750 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . COVER, right angle motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . MOTOR, gear 24VDC 122RPM 20:1 ratio (consisting of) . . . . . . . . . . . . . . . .
. . . . KEY, woodruff .118 x .380 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . WASHER, wave .405 ID x .740 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . RING, rtng ext .394 shaft x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . FITTING, hose brs barbed M 3/16tbg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . SCREW, .375–16 x 1.25hexhd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . WASHER, flat stl SAE .312 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . KNOB, plstc T 1.000 lg x .312-18 x 2.000 bar . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . CARRIER, drive roll w/components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . SCREW, M 4–.7 x 12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . SCREW, M 6–1.0 x 20 soc hd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . WASHER, flat .250 ID x .437 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . BUSHING, motor mtg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . WASHER, flat .438 ID X 1.00 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . WASHER, lock .380 ID X .683 OD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . GUIDE, anti-wear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
2
1
1
2
1
1
1
1
3
3
3
1
1
1

See Table 6-1
Drive Roll & Wire Guide Kits.

. Hardware is common and

not available unless listed.

Figure 6-5. Wire Drive And Gears

148 529-H

*Recommended Spare Parts.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM-198 683 Page 35

Table 6-1. Drive Roll And Wire Guide Kits

Note

Base selection of drive rolls upon the following recommended usages:
1
2
3
4
5

V-Grooved rolls for hard wire.
U-Grooved rolls for soft and soft shelled cored wires.
U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
V-Knurled rolls for hard shelled cored wires.
Drive roll types may be mixed to suit particular requirements (example: V-Knurled roll in combination
with U-Grooved).

Wire Diameter

Drive Roll
Part No.

Type

Inlet
Wire Guide

087 131

087 130

V-Grooved

056 192

0.8 mm

079 594

053 695

V-Grooved

056 192

.035 in.

0.9 mm

079 595

053 700

V-Grooved

056 192

.045 in.

.045 in.

1.2 mm

079 596

053 697

V-Grooved

056 193

.052 in.

.052

1.3 mm

079 597

053 698

V-Grooved

056 193

1/16 in.

.062

1.6 mm

079 598

053 699

V-Grooved

Fraction

Decimal

Metric

.023/.025 in.

.023/.025 in.

0.6 mm

.030 in.

.030 in.

.035 in.

Kit No.

056 195
Ref. S-0026-B/7-91

Item
No.

Dia.
Mkgs.

Part
No.

Description

Quantity

Figure 6-6. Panel, Rear w/Components (Fig 6-1 Item 3)
. . . 1 . . . . . . . . . . . 148 809
. . . 2 . . . FM1 . . . 188 706
. . . 3 . . . . . . . . . . . 188 709
. . . 4 . . . GS1 . . . 125 785
. . . 5 . . . . . . . . . . . 143 810
. . . 6 . . . . . . . . . . . 169 654
. . . 7 . . . . . . . . . . . 188 441
. . . 8 . . . . . . . . . . . 605 227
. . . 9 . . . . . . . . . . . 178 126
. . . . . . . . . . . . . . . . . 193 328

. . . BLADE, fan 9 in 5wg 34deg .309 bore CCW . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . MOTOR, fan 230V 50/60 Hz 1550RPM .312dia shaft . . . . . . . . . . . . . . . . . . .
. . . WINDTUNNEL, 9 in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . VALVE, 24VAC 2 way custom port 1/8 orf . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . +PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . BRACKET, support tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . CHAIN, weldless 2/0 x 31.000 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . NUT, nyl hex jam .750NPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . CONNECTOR, clamp cable .690/1.070 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . LABEL, warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. Hardware is common and

1
1
1
1
1
1
1
1
1
1

6

not available unless listed.

5

4

7

8
9

3

2
1

Ref. 802 088-A

Figure 6-6. Panel, Rear w/Components
+When ordering a component originally displaying a precautionary label, the label should also be ordered.
To maintain the factory original performance of your equipment, use only Manufacturer’s Suggested
Replacement Parts. Model and serial number required when ordering parts from your local distributor.
OM–198 683 Page 36

Notes

Notes

Effective October 1, 1999
Warranty Questions?

Call
1-877-HOBART1
for your local
Hobart distributor.
Service
You always get the fast,
reliable response you
need. Most replacement
parts can be in your
hands in 24 hours.
Support
Need fast answers to the
tough welding questions?
Contact your distributor or
call 1-800-332-3281. The
expertise of the distributor
and Hobart is there to
help you, every step of
the way.

5/3/1 WARRANTY applies to all Handler 135 and 175 models, Airforce 250, 250A, and 375
models, and Champion 10,000 models.This warranty also applies to the Beta-Mig 1800, Champ
1435, 2060, 8500 models, Ironman 250, Stickmate models, Tigmate models, and HSW-15 and
HSW-25 spot welder models effective with Serial No. KK200262 and newer.
This limited warranty supersedes all previous Hobart warranties and is exclusive with
no other guarantees or warranties expressed or implied.
Hobart products are serviced by Hobart or Miller Authorized Service Agencies.
LIMITED WARRANTY – Subject to the terms and conditions
below, Hobart/Miller Electric Mfg. Co., Appleton, Wisconsin,
warrants to its original retail purchaser that new Hobart
equipment sold after the effective date of this limited warranty
is free of defects in material and workmanship at the time it is
shipped by Hobart. THIS WARRANTY IS EXPRESSLY IN
LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED,
INCLUDING
THE
WARRANTIES
OF
MERCHANTABILITY AND FITNESS.
Within the warranty periods listed below, Hobart/Miller will
repair or replace any warranted parts or components that fail
due to such defects in material or workmanship. Hobart/Miller
must be notified in writing within thirty (30) days of such defect
or failure, at which time Hobart/Miller will provide instructions
on the warranty claim procedures to be followed.
Hobart/Miller shall honor warranty claims on warranted
equipment listed below in the event of such a failure within the
warranty time periods. All warranty time periods start on the
date that the equipment was delivered to the original retail
purchaser, or one year after the equipment is sent to a North
American distributor or eighteen months after the equipment
is sent to an International distributor.
1.

2.

3.

4.

5 Years — Parts and Labor

*
*

Original Main Power Rectifiers
Transformers

*
*

Stabilizers
Reactors

*

Rotors, Stators and Brushes

3 Years — Parts and Labor

*

Drive Systems

*
*

PC Boards
Idle Module

*
*

Solenoid Valves
Switches and Controls

*

Spot Welder Transformer

1 Year — Parts and Labor (90 days for industrial use)

*

Motor-Driven Guns

*
*

MIG Guns/TIG Torches
Relays

*
*

Contactors
Regulators

*
*

Water Coolant Systems
HF Units

*
*

Running Gear/Trailers
Plasma Cutting Torches

*
*

Remote Controls
Replacement Parts (No labor)

*
*

Accessories
Field Options
(NOTE: Field options are covered for the
remaining warranty period of the product they are
installed in, or for a minimum of one year —
whichever is greater.)

Engines, batteries and tires are warranted separately by
the manufacturer.

Hobart’s 5/3/1 Limited Warranty shall not apply to:
1.

Consumable components such as contact tips,
cutting nozzles, slip rings, drive rolls, gas diffusers,
plasma torch tips and electrodes, weld cables, and
tongs and tips, or parts that fail due to normal wear.

2.

Items furnished by Hobart/Miller, but manufactured by
others, such as engines or trade accessories. These
items are covered by the manufacturer’s warranty, if any.

3.

Equipment that has been modified by any party other
than Hobart/Miller, or equipment that has been
improperly installed, improperly operated or misused
based upon industry standards, or equipment which has
not had reasonable and necessary maintenance, or
equipment which has been used for operation outside of
the specifications for the equipment.

HOBART PRODUCTS ARE INTENDED FOR PURCHASE
AND USE BY COMMERCIAL/INDUSTRIAL USERS AND
PERSONS TRAINED AND EXPERIENCED IN THE USE
AND MAINTENANCE OF WELDING EQUIPMENT.
In the event of a warranty claim covered by this warranty, the
exclusive remedies shall be, at Hobart’s/Miller’s option: (1)
repair; or (2) replacement; or, where authorized in writing by
Hobart/Miller in appropriate cases, (3) the reasonable cost of
repair or replacement at an authorized Hobart/Miller service
station; or (4) payment of or credit for the purchase price (less
reasonable depreciation based upon actual use) upon return
of the goods at customer’s risk and expense. Hobart’s/Miller’s
option of repair or replacement will be F.O.B., Factory at
Appleton, Wisconsin, or F.O.B. at a Hobart/Miller authorized
service facility as determined by Hobart/Miller. Therefore no
compensation or reimbursement for transportation costs of
any kind will be allowed.
TO THE EXTENT PERMITTED BY LAW, THE REMEDIES
PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE
REMEDIES. IN NO EVENT SHALL HOBART/MILLER BE
LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL
OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF
PROFIT), WHETHER BASED ON CONTRACT, TORT OR
ANY OTHER LEGAL THEORY.
ANY EXPRESS WARRANTY NOT PROVIDED HEREIN
AND ANY IMPLIED WARRANTY, GUARANTY OR
REPRESENTATION AS TO PERFORMANCE, AND ANY
REMEDY FOR BREACH OF CONTRACT TORT OR ANY
OTHER LEGAL THEORY WHICH, BUT FOR THIS
PROVISION,
MIGHT
ARISE
BY
IMPLICATION,
OPERATION OF LAW, CUSTOM OF TRADE OR COURSE
OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR PARTICULAR
PURPOSE, WITH RESPECT TO ANY AND ALL
EQUIPMENT FURNISHED BY HOBART/MILLER IS
EXCLUDED AND DISCLAIMED BY Hobart/Miller.
Some states in the U.S.A. do not allow limitations of how long
an implied warranty lasts, or the exclusion of incidental,
indirect, special or consequential damages, so the above
limitation or exclusion may not apply to you. This warranty
provides specific legal rights, and other rights may be
available, but may vary from state to state.
In Canada, legislation in some provinces provides for certain
additional warranties or remedies other than as stated herein,
and to the extent that they may not be waived, the limitations
and exclusions set out above may not apply. This Limited
Warranty provides specific legal rights, and other rights may
be available, but may vary from province to province.
hobart retail 4/00

Owner’s Record
Please complete and retain with your personal records.
Model Name

Serial/Style Number

Purchase Date

(Date which equipment was delivered to original customer.)

Distributor
Address
City
State

Zip

Resources Available
Always provide Model Name and Serial/Style Number.
To locate a Distributor,
retail or service location:

Contact your Distributor for:
Welding Supplies and Consumables

Call 1-877-Hobart1 or visit our website at
www.HobartWelders.com

Options and Accessories
Personal Safety Equipment

For technical assistance:
Call 1-800-332-3281

Service and Repair
Replacement Parts
Training (Schools, Videos, Books)

Hobart Welding Products

Technical Manuals (Servicing Information
and Parts)

An Illinois Tool Works Company
600 West Main Street
Troy, OH 45373 USA

Circuit Diagrams

For Technical Assistance:
Call1-800-332-3281
For Literature Or Nearest Dealer:
Call 1-877-Hobart1

Welding Process Handbooks
Contact the Delivering Carrier for:

File a claim for loss or damage during
shipment.

For assistance in filing or settling claims,
contact your distributor and/or equipment
manufacturer’s Transportation Department.

PRINTED IN USA

 2000 Hobart Welding Products.

1/00



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2000:09:19 07:00:42
Producer                        : Acrobat Distiller 4.05 for Windows
Modify Date                     : 2000:09:19 07:00:47-05:00
Page Count                      : 44
EXIF Metadata provided by EXIF.tools

Navigation menu