General Specifications Operating Temperature 0º to 60ºC (32º to 140ºF) Storage Temperature -20º to 70ºC (-4º to 158ºF) Humidity 5 to 95% (non-condensing) Environmental Air No corrosive gases permitted Vibration IEC60068-2-6 (Test Fc) Shock IEC60068-2-27 (Test Ea) Field to Logic Side Isolation 1800VAC applied for 1 second Insulation Resistance > 10MΩ @ 500VDC Heat Dissipation 2.47W Enclosure Type Open Equipment UL508 File E139594, Canada & USA Agency Approvals CE (EN61131-2*) Module Keying to Backplane Electronic Module Location Any I/O slot in a Productivity2000 System Field Wiring EU Directive Use ZIPLink Wiring System or removable terminal block (not included). See “Wiring Options” on page 5. See the “EU Directive” topic in the Productivity2000 Help File. Information can also be obtained at: www.productivity2000.com 2000 1I00.00 2I04.00 3I00.00 4I04.00 5I00.00 6I04.00 7I00.00 8I SPARE P2-8AD4DA-1 Analog Input/Output The P2-8AD4DA-1 Current Analog Input/Output Module provides eight channels of 0-20 mA inputs and four channels of 4-20 mA outputs for use with the Productivity2000 System. General Specifications . . . . . . . . . . . . . . . . . . . . . . . Input Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . Output Specifications . . . . . . . . . . . . . . . . . . . . . . . . Wiring Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Module Configuration . . . . . . . . . . . . . . . . . . . . . . . . Linear Scaling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-Linear Scaling. . . . . . . . . . . . . . . . . . . . . . . . . . OLED Panel Display Menus. . . . . . . . . . . . . . . . . . . Module Installation Procedure. . . . . . . . . . . . . . . . . . QR Code. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hot Swap Information. . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagram and Schematic. . . . . . . . . . . . . . . . . Warning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removable Terminal Block Specifications. . . . . . . . 1 2 2 3 3 4 4 5 6 6 6 7 8 8 Connector Type (not included) 18-Position Removable Terminal Block Weight 90g (3.2 oz) *Meets EMC and Safety requirements. See the D.O.C. for details. Terminal Block sold separately, (see wiring options on page 3). Warranty: Thirty-day money-back guarantee. Two-year limited replacement. (See www.productivity2000.com for details). Sales 800-633-0405 www.productivity2000.com 1 Input Specifications Input Channels 8 (1 common) Output Specifications Output Channels 4 (1 common) Module Signal Input Range 0-20 mA (sourcing) Module Signal Output Range 4-20 mA 12-16 bit, depending on input resolution Fine: 8ms, 0.305 μA, 16 bit Input Resolution & Update Rate Medium: 2ms, 1.22 μA, 14 bit (See Note 1) Coarse: 700μs, 4.88 μA, 12 bit Data Range 0-65535 counts Output Signal Resolution 16-bit Resolution Value of LSB (least significant bit) 0.244 μA / count 1 LSB = 1 count Data Range 0 - 65535 counts Input Type Output Type Current sourcing: 20mA max Output Value in Fault Mode ≤ 4mA Load Impedance (Minimum External Power Supply) 0 - 480Ω (19.2 VDC) 0 - 600Ω (21.6 VDC) 0 - 715Ω (24VDC) 0 - 840Ω (26.4 VDC) 0 - 1010Ω (30VDC) Maximum Inductive Load 1mH Allowed Load Type Grounded Signal Resolution Single Ended (1 common) Maximum Continuous Overload ±31mA Input Impedance 250Ω ±0.1%, 1/4W Hardware Filter Characteristics Open Circuit Detection Time Low pass 1st order, -3dB @ 48Hz Fine 57ms Medium: 17ms Coarse: 7ms Zero reading within 1s Conversion Method Successive approximation Maximum Inaccuracy 0.1% of range Accuracy vs. Temperature ±15ppm/°C maximum Maximum Full Scale Calibration Error (not including offset error) ±0.065% of full scale All Channel Update Rate (See Note 2) Maximum Inaccuracy 0.1% of range 0.015% of range maximum Linearity Error (end to end) Monotonic with no missing codes Input Stability and Repeatability ±0.015% of range (after 10 minute warm-up) Full Scale Calibration Error ±0.05% of range maximum (not including offset) Offset Calibration Error ±0.05% of range maximum Maximum Crosstalk -96dB ±1 -0.015% of full scale maximum Recommended Fuse (external) Edison S500-32-R, 0.032 A fuse External DC Power Required 24VDC (-20% / +25%), 145mA Note 1: The Input Resolution of Fine returns 16 bit resolution. Medium and Coarse are 14 and 12 bit respectively. The 12 and 14 bit input values are scaled to 0-65535. Note 2: Valid when all channels are set for the same Input Resolution. 2 www.productivity2000.com Maximum Offset Calibration Error Output Stability and Repeatability ±0.065% of full scale ±15ppm/°C max full scale calibration change (±0.0025% of range/°C) -96dB, 1 LSB ±0.015% of range maximum Monotonic with no missing codes ±0.015% after 10 minute warm-up typical Output Ripple 0.01% of full scale at 50/60 Hz Output Setting Time Rising Time 200μs Falling Time 135μs (full scale change) All Channel Update Rate 3.55 ms Maximum Continuous Overload Outputs open circuit protected Type of Output Protection Electronically current limited to 20mA or less Output Signal (power-up, -down) ≤ 4mA Accuracy vs. Temperature Max Crosstalk Linearity Error (End to End) Tech Support 770-844-4200 Wiring Diagram Schematic Current Input Circuits .032A 4-Wire 4-20 mA Transmitter AC or DC fuse .032A – Output Channels +24VDC User Supplied Power 3-Wire Transmitter + – User Supplied Transmitter Power 4-Wire Transmitter Note: Do not connect both ends of shield. Current Output Circuits - + CH5 ADC CH6 ADC CH7 ADC 9 10 11 12 13 14 15 16 17 18 + CH4 ADC 8 COM – CH3 ADC 7 .032A + 3-Wire Current Transmitter CH2 ADC 6 fuse + CH1 ADC 5 +24VDC User Supplied Power 2-Wire Transmitter COM I1+ I2+ I3+ I4+ I5+ I6+ I7+ I8+ COM I1+ I2+ I3+ I4+ COM COM 0V 24V+ 4 – 3 + 2 + 1 2-Wire 4-20 mA Transmitter INTERNAL MODULE CIRCUITRY An Edison S500-32-R 0.032A fast-acting fuse is recommended for all 4-20 mA current loops. fuse Input Channels – CH8 ADC CH1 DAC CH2 DAC CH3 DAC CH4 DAC ISOLATED ANALOG CIRCUIT POWER 24 VDC User Supplied Power ISOLATED ANALOG CIRCUIT COMMON 4 - 20mA Load Note: This module includes input and output channels. Before connecting field wiring, verify that you are connecting to the appropriate terminals Note: Shield is connected to common at the source device. Sales 800-633-0405 www.productivity2000.com 7 Module Installation QR Code WARNING: Do not apply field power until the following steps are completed. See hot-swapping procedure for exceptions. 2 rotate to seated position Step One: Align module catch with base slot and rotate module into connector. 1 Align with slot Step Two: Pull top locking tab toward module face. Click indicates lock is engaged. Locked Unlocked Use any QR Code reader application to display the module’s product insert. Step Three: Attach field wiring using the removable terminal block or ZIPLink wiring system. WIRE STRIP LENGTH 6 www.productivity2000.com Caution: If possible, remove field power prior to proceeding. If not, then EXTREME care MUST be taken to prevent damage to the module, or even personal injury due to a short circuit from the live terminal block. Important Hot-Swap Information The Productivity2000 System supports hot-swap! Individual modules can be taken offline, removed, and replaced while the rest of the system continues controlling your process. Before attempting to use the hotswap feature, be sure to read the hot-swap topic in the programming software’s help file or our online documentation at AutomationDirect.com for details on how to plan your installation for use of this powerful feature. Tech Support 770-844-4200 Module Configuration Wiring Options 1 ZIPLink Connection System Cable + ZIPLink Module = Complete System ZIPLink pre-wired terminal block cables 0.5m (1.6FT) cable 1.0m (3.3FT) cable 2.0m (6.6FT) cable ZL-P2-CBL18 ZL-P2-CBL18-1 ZL-P2-CBL18-2 Using the Hardware Configuration tool in the Productivity Suite programming software, drag and drop the P2-8AD4DA-1 module into the base configuration. Select Automatic Module Verification or No Verification and Enable Hot Swap. Also specify Input Resolution for inputs and Stop Mode Value for outputs. If desired, assign a User Tagname to each input and output point (channel) selected and to each Status Bit Item. ZIPLink Modules Feed through 2 Terminal Block with pigtail cable 1.0m (3.3FT) cable 2.0m (6.6FT) cable 3 4 ZL-RTB20 Screw Terminal Block only Spring Clamp Terminal Block only Sales 800-633-0405 ZL-P2-CBL18-1P ZL-P2-CBL18-2P P2-RTB (Quantity 1) P2-RTB-1 (Quantity 1) www.productivity2000.com 3 Linear Scaling Non-Linear Scaling The Scale (Linear) function can be used to: The Scale (Non-Linear) function can be used for Non-Linear applications. • Convert analog field input signals from the range which is native to the analog input module to an application specific range. • Convert an application specific range to a range which is native to the analog output module. • Make other linear conversions in ranges appropriate to the application. Level Transmitter Tank Level 0 65535 220 12500 Select the Input and Output tags appropriate for the application. Convert raw input signals to engineering units for use in the program, or convert engineering units to output signals for control purposes Level Transmitter 0 1 2 3 4 5 6 6.5 7 0 0 0 0 0 0 0 Tank Level 0 .5 1 1.55 2.25 3 4.55 6.75 7 0 0 0 Select the 0 minimum and maximum values of0 the raw input signal. These values will 0 relate to the minimum and maximum scaled values. 0 7 6 max 5 4 3 2 1 0 min min 4 www.productivity2000.com 1 2 3 4 5 6 7 max Tech Support 770-844-4200 OLED Panel Display Power On PASSED SELF TEST Appears initially Hold SEL button down to cycle through primary screens. Release button to select screen. DISPLAY SETUP INFO DISPLAY STATUS INFO DISPLAY UNITS DECIMAL COUNTS DISPLAY UNITS HEX COUNTS DISPLAY UNITS mA These screens will then auto cycle P28AD4DA-1 Fw. Rev. 1.00 In: 0-20mA Out: 4-20mA Channels Enabled: 7 Fault Messages – Appear in place of data during a fault condition. This screen will auto cycle with status information End of Status Menu List Momentarily Press 1I 00000 SEL button to 2I 00000 toggle through 3I 00000 secondary displays 4I 00000 Error Messages – An existing error will be inserted into the cycling Status Info screen MISSING EXTERNAL 24VDC SELFTEST FAIL REPLACE MODULE End of Status Menu List MISSING CONFIG DATA 1I OVER 2I UNDER 3I 4I Sales 800-633-0405 On if input is greater than or equal to 20 mA. On if input is less than or equal to 0 mA. 1I 2I 3I 4I 0000H 0000H 0000H 0000H 1I00.0mA 2I00.0mA 3I00.0mA 4I00.0mA 5I 6I 7I 8I 00000 00000 00000 SPARE 5I 6I 7I 8I 0000H 0000H 0000H SPARE 5I00.0mA 6I00.0mA 7I00.0mA 8I SPARE 1I 2I 3I 4I 5I 6I 7I 8I 00000 00000 00000 00000 00000 00000 00000 SPARE 1I 2I 3I 4I 5I 6I 7I 8I 0000H 0000H 0000H 0000H 0000H 0000H 0000H SPARE 1I04.0mA 2I04.0mA 3I04.0mA 4I04.0mA 5I04.0mA 6I04.0mA 7I04.0mA 8I SPARE 1O 2O 3O 4O 00000 00000 00000 00000 1O 2O 3O 4O 0000H 0000H 0000H 0000H 1O04.0mA 2O04.0mA 3O04.0mA 4O04.0mA Note: SPARE denotes deselected channel www.productivity2000.com 5 WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect.com® we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Removable Terminal Block Specifications Part Number P2-RTB P2-RTB-1 Number of positions 18 Screw Terminals 18 Spring Clamp Terminals 30 - 16 AWG (0.051 - 1.31 mm²) 28-16 AWG (0.081 - 1.31 mm²) Solid / Stranded Conductor Solid / Stranded Conductor 3/64 in. (1.2 mm) Insulation Maximum 3/64 in (1.2 mm) Insulation Maximum 1/4 in (6 - 7 mm) Strip Length 19/64 in (7 - 8 mm) Strip Length Wire Range Conductors “USE COPPER CONDUCTORS, 75ºC” or equivalent. Screw Driver Width 1/8 in (3.8 mm) Maximum Screw Size Screw Torque M2 N/A 2.5 lb·in (0.28 N·m) N/A Document Name P2-8AD4DA-1-DS Edition/Revision 1st Ed. Date 3/9/2015 Copyright 2015, AutomationDirect.com Incorporated/All Rights Reserved Worldwide 8 www.productivity2000.com Tech Support 770-844-4200
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Create Date : 2015:03:12 14:27:20-04:00 Metadata Date : 2015:03:12 14:36:13-04:00 Modify Date : 2015:03:12 14:36:13-04:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:4fe9664c-cace-458a-ac3b-d2a1d6ae80e0 Original Document ID : xmp.did:E534B99C17D6E311BBDA8DE0A731EE6A Document ID : xmp.id:7ae4e52c-e6a6-ab4f-a892-4c531b9684f3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:5dbef0f3-9b34-a140-9a5a-a5db0d141ec6 Derived From Document ID : xmp.did:D7DF6CF05FFCE311B967B674276BA900 Derived From Original Document ID: xmp.did:E534B99C17D6E311BBDA8DE0A731EE6A Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2015:03:12 14:27:20-04:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 8 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools