PSM Series Industrial Power Supply
* AC-Input Voltage
Range

Part Number
PSM12-078S

85VAC - 264VAC
Universal Input
50 / 60Hz

PSM24-090S
PSM24-090S-N
PSM12-156S

115VAC / 230VAC
Autorange
85VAC - 132VAC
187VAC - 264VAC
50 / 60Hz

PSM24-180S
PSM24-360S
PSM24-600S

Output Power **Output
Max.

*** Output Voltage
Adjustment Range

Recommended Circuit
Breaker (Characteristic B)

78 Watt

12.0VDC / 6.0A

12.0 - 14.0VDC

90 Watt

24.0VDC / 3.75A

24.0 - 28.0VDC

90 Watt

24.0VDC / 3.75A

24.0 - 28.0VDC

156Watt

12.0VDC / 12.0A

12.0 - 14.0VDC

180 Watt

24.0VDC / 7.5A

24.0 - 28.0VDC

360 Watt

24.0VDC / 15.0A

24.0 - 28.0VDC

10 - 16A

600 Watt

24.0VDC / 25.0A

24.0 - 28.0VDC

16 - 25A

6 - 16A

Note: All output terminals shall be wired to the load.
* Observe output current derating at operation below an input voltage of 110VAC
** Maximum output current at Vout nom
** Adjustable by potentiometer with a screwdriver.

@ Vin=115VAC

@ Vin=230VAC

Power Consumption

@ Vin=115VAC

@ V20in=230VAC

PSM12-078S

2.0A typ.

1.0A typ.

PSM12-078S

95 Watt typ.

93 Watt typ.

PSM24-090S (N)

2.1A typ.

1.0A typ.

PSM24-090S (N)

106 Watt typ.

105 Watt typ.

PSM12-156S

2.5A typ.

1.4A typ.

PSM12-156S

175 Watt typ.

173 Watt typ.

PSM24-180S

2.8A typ.

1.5A typ.

PSM24-180S

209 Watt typ.

207 Watt typ.

PSM24-360S

5.0A typ.

2.5A typ.

PSM24-360S

425 Watt typ.

412 Watt typ.

PSM24-600S

10.0A typ.

5.0A typ.

PSM24-600S

690 Watt typ.

670 Watt typ.

Operating temperature
range: Natural Air Convection -25°C - +70°C max , -13°F - +158°F max
Cooling

Output Power Derating:
above +40°C [104°F]

PSM12-078S
PSM24-090S(N)
PSM12-156S
PSM24-180S
PSM24-360S
PSM24-600S

Storage temperature range:

-25°C - +85°C max (-13°F - +185°F max)

Parallel Operation:

Up to 5 power supplies possible.User selectable standard mode and parallel mode by jumper on PCB.

Connections:

Screw type terminal COMBICON. Recommended tightening torque 0.5 to 0.6Nm

Case material:

Aluminium (chassis) and Zinc-plated steel (cover)

www.automationdirect.com

Input current:

0.5%/K
1.5%/K
3.0%/K
3.0%/K
3.0%/K
6.0%/K

To Install
1.
2.
3.
4.
5.
6.

Read and follow Safety and Installation instructions on the back of this page.
Hook top of power supply’s DIN rail clip on DIN rail
Push down tab on top of power supply to open DIN rail clip.
Rotate power supply into DIN rail and release tab.
Verify the DIN rail clip is securely fastened on DIN rail.
Connect wires as indicated on power supply. All output terminals shall be wired to the load.
RHINO Industrial Power Supplies Installation Instructions		

Rev: 04/16

1

Rhino Power Supplies – PSM Series
Safety Instructions:

Installation Instructions:
• This power supply is designed for professional indoor systems.
In operation the power supply must not be accessible. It may
be installed and put into service by qualified personnel only.
• Do not operate without PE connection! To comply with EMC
and safety standards (CE mark, approvals) the power supply
must be operated only if PE terminal is connected to the
non-fused earth conductor.
• The correct mounting position for optimal cooling performance must be observed. Do not cover any ventilation holes.
Please allow minimum free space of 80mm (3.15in.) above and
below, and 50mm (1.97”) on each side of the power supply for
air convection. Observe power derating.
• All output terminals shall be wired to the load.
• The internal fuse is not accessible, as it may not be replaced
by the user. If this internal fuse has blown, the power supply
likely has an internal defect and, for safety reasons, must be
discarded, or, if under warranty, returned. In case this internal
fuse has to be replaced in the field, replace only with same type
and rating of fuse for continued protection against risk of fire.
• Recycling: The unit contains elements that are suitable for
recycling, and components that need special disposal. You are
therefore requested to make sure that the power supply will be
recycled environment friendly at the end of its service life.
•W
 arning: To minimize the risk of potential safety problems,
follow all applicable local and national codes that regulate the
installation and operation of your equipment. These codes
vary from area to area and it is your responsibility to determine
which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the
latest revision of these codes.
• Equipment damage or serious injury to personnel can
result from the failure to follow all applicable codes and
standards. We do not guarantee the products described
in this publication are suitable for your particular application, nor do we assume any responsibility for your
product design, installation or operations.
• If you have any questions concerning the installation or
operation of this equipment, or if you need additional
information, please call us at 770-844-4200.
• This publication is based on information that was available at the time it was printed. At Automationdirect.
com™ we constantly strive to improve our products and
services, so we reserve the right to make changes to the
products and/or publications at any time without notice
and without any obligation. This publication may also
discuss features that may not be available in certain revisions of the product.

RHINO Industrial Power Supplies Installation Instructions		

Rev: 04/16

www.automationdirect.com

•
Before installation read these instructions carefully and
completely. These installation instructions cannot cover every
possible installation, operation or maintenance situation.
Further information can be obtained from the product datasheets, which can be downloaded, from the Internet at http://
www.automationdirect.com.
• These power supplies are constructed in accordance with the
safety requirements of IEC/EN/60950, EN 60204, EN50178,
IEC/EN 60079-15 and EN61558-2-8. They are approved
(BG-mark) in accordance with EN60950, EN50178 and fulfil
the requirements of the Low Voltage Directive (LVD). They
are Approved by CSA.
• Before any installation, maintenance or modification work
ensure that the main switch is switched off and prevented from
being switched on again. Non-observance, touching of any live
components or improper handling of this power supply can
result in death, severe personal injury or substantial property
damage. Proper and safe operation is dependent on proper
storage, handling, installation and operation.
• Compliance with the relevant national regulations (in the USA,
Europe and other countries) must be ensured. Before operation
is started the following conditions must be ensured:
• Connection to mains supply in compliance with
national regulations (NEC, NEMA, VDE0100 and
EN50178).
• Use of stranded wires, all strands must be fastened in
the terminal blocks. (Potential danger of contact with
the case)
• Power supply and mains cables must be sufficiently
fused.
• Degree of protection I to IEC536.The non-fused
protective earth connection must be connected to the
FG terminal (Protection Class I).
• All output wires must be rated for the power supply
output current and must be connected with the
correct polarity.
• Sufficient cooling must be ensured.
•N
 ever work on the power supply if power is supplied! Risk of
electric arcs and electrical shock, which can cause death, severe
personal injury or substantial property damage.
•W
 arning: Hazardous voltages and components storing a very
substantial amount of energy are present in this power supply
during normal operating conditions. However, these are inaccessible. Improper handling may result in an electric shock or
serious burns! Do not open the power supply until at least 5
minutes after it has been disconnected from the mains on all
poles.
• Only trained personnel may open the power supply.

• Do not introduce any objects into the power supply. The
output voltage adjustment potentiometer may only be actuated
using an insulated screwdriver.
• Keep away from fire and water

2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Create Date                     : 2016:04:20 09:15:14-04:00
Metadata Date                   : 2016:04:20 09:20:54-04:00
Modify Date                     : 2016:04:20 09:20:54-04:00
Creator Tool                    : Adobe InDesign CC 2014 (Windows)
Instance ID                     : uuid:f7b504f7-8300-424b-9be4-e7e87b7c829b
Original Document ID            : xmp.did:EA3D3524EA06E611A60CE9D11C6056F8
Document ID                     : xmp.id:a264d1c4-d087-6f4c-8863-16f7da832aec
Rendition Class                 : proof:pdf
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2014 (Windows)
History Changed                 : /
History When                    : 2016:04:20 09:15:14-04:00
Derived From Instance ID        : xmp.iid:3c597508-0970-4643-86df-dc9760080e8f
Derived From Document ID        : xmp.did:EA3D3524EA06E611A60CE9D11C6056F8
Derived From Original Document ID: xmp.did:EA3D3524EA06E611A60CE9D11C6056F8
Derived From Rendition Class    : default
Format                          : application/pdf
Title                           : Rhino PSM Series Power Supplies Installation
Creator                         : AutomationDirect
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Layout                     : SinglePage
Page Count                      : 2
Author                          : AutomationDirect
Warning                         : [Minor] Ignored duplicate Info dictionary
EXIF Metadata provided by EXIF.tools

Navigation menu