Rhino Power Supplies – PSM Series INSTALLATION INSTRUCTIONS PSM Series Industrial Power Supply * AC-Input Voltage Range Part Number PSM12-078S 85VAC - 264VAC Universal Input 50 / 60Hz PSM24-090S PSM24-090S-N PSM12-156S 115VAC / 230VAC Autorange 85VAC - 132VAC 187VAC - 264VAC 50 / 60Hz PSM24-180S PSM24-360S PSM24-600S Output Power **Output Max. *** Output Voltage Adjustment Range Recommended Circuit Breaker (Characteristic B) 78 Watt 12.0VDC / 6.0A 12.0 - 14.0VDC 90 Watt 24.0VDC / 3.75A 24.0 - 28.0VDC 90 Watt 24.0VDC / 3.75A 24.0 - 28.0VDC 156Watt 12.0VDC / 12.0A 12.0 - 14.0VDC 180 Watt 24.0VDC / 7.5A 24.0 - 28.0VDC 360 Watt 24.0VDC / 15.0A 24.0 - 28.0VDC 10 - 16A 600 Watt 24.0VDC / 25.0A 24.0 - 28.0VDC 16 - 25A 6 - 16A Note: All output terminals shall be wired to the load. * Observe output current derating at operation below an input voltage of 110VAC ** Maximum output current at Vout nom ** Adjustable by potentiometer with a screwdriver. @ Vin=115VAC @ Vin=230VAC Power Consumption @ Vin=115VAC @ V20in=230VAC PSM12-078S 2.0A typ. 1.0A typ. PSM12-078S 95 Watt typ. 93 Watt typ. PSM24-090S (N) 2.1A typ. 1.0A typ. PSM24-090S (N) 106 Watt typ. 105 Watt typ. PSM12-156S 2.5A typ. 1.4A typ. PSM12-156S 175 Watt typ. 173 Watt typ. PSM24-180S 2.8A typ. 1.5A typ. PSM24-180S 209 Watt typ. 207 Watt typ. PSM24-360S 5.0A typ. 2.5A typ. PSM24-360S 425 Watt typ. 412 Watt typ. PSM24-600S 10.0A typ. 5.0A typ. PSM24-600S 690 Watt typ. 670 Watt typ. Operating temperature range: Natural Air Convection -25°C - +70°C max , -13°F - +158°F max Cooling Output Power Derating: above +40°C [104°F] PSM12-078S PSM24-090S(N) PSM12-156S PSM24-180S PSM24-360S PSM24-600S Storage temperature range: -25°C - +85°C max (-13°F - +185°F max) Parallel Operation: Up to 5 power supplies possible.User selectable standard mode and parallel mode by jumper on PCB. Connections: Screw type terminal COMBICON. Recommended tightening torque 0.5 to 0.6Nm Case material: Aluminium (chassis) and Zinc-plated steel (cover) www.automationdirect.com Input current: 0.5%/K 1.5%/K 3.0%/K 3.0%/K 3.0%/K 6.0%/K To Install 1. 2. 3. 4. 5. 6. Read and follow Safety and Installation instructions on the back of this page. Hook top of power supply’s DIN rail clip on DIN rail Push down tab on top of power supply to open DIN rail clip. Rotate power supply into DIN rail and release tab. Verify the DIN rail clip is securely fastened on DIN rail. Connect wires as indicated on power supply. All output terminals shall be wired to the load. RHINO Industrial Power Supplies Installation Instructions Rev: 04/16 1 Rhino Power Supplies – PSM Series Safety Instructions: Installation Instructions: • This power supply is designed for professional indoor systems. In operation the power supply must not be accessible. It may be installed and put into service by qualified personnel only. • Do not operate without PE connection! To comply with EMC and safety standards (CE mark, approvals) the power supply must be operated only if PE terminal is connected to the non-fused earth conductor. • The correct mounting position for optimal cooling performance must be observed. Do not cover any ventilation holes. Please allow minimum free space of 80mm (3.15in.) above and below, and 50mm (1.97”) on each side of the power supply for air convection. Observe power derating. • All output terminals shall be wired to the load. • The internal fuse is not accessible, as it may not be replaced by the user. If this internal fuse has blown, the power supply likely has an internal defect and, for safety reasons, must be discarded, or, if under warranty, returned. In case this internal fuse has to be replaced in the field, replace only with same type and rating of fuse for continued protection against risk of fire. • Recycling: The unit contains elements that are suitable for recycling, and components that need special disposal. You are therefore requested to make sure that the power supply will be recycled environment friendly at the end of its service life. •W arning: To minimize the risk of potential safety problems, follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. • Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation or operations. • If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at 770-844-4200. • This publication is based on information that was available at the time it was printed. At Automationdirect. com™ we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. RHINO Industrial Power Supplies Installation Instructions Rev: 04/16 www.automationdirect.com • Before installation read these instructions carefully and completely. These installation instructions cannot cover every possible installation, operation or maintenance situation. Further information can be obtained from the product datasheets, which can be downloaded, from the Internet at http:// www.automationdirect.com. • These power supplies are constructed in accordance with the safety requirements of IEC/EN/60950, EN 60204, EN50178, IEC/EN 60079-15 and EN61558-2-8. They are approved (BG-mark) in accordance with EN60950, EN50178 and fulfil the requirements of the Low Voltage Directive (LVD). They are Approved by CSA. • Before any installation, maintenance or modification work ensure that the main switch is switched off and prevented from being switched on again. Non-observance, touching of any live components or improper handling of this power supply can result in death, severe personal injury or substantial property damage. Proper and safe operation is dependent on proper storage, handling, installation and operation. • Compliance with the relevant national regulations (in the USA, Europe and other countries) must be ensured. Before operation is started the following conditions must be ensured: • Connection to mains supply in compliance with national regulations (NEC, NEMA, VDE0100 and EN50178). • Use of stranded wires, all strands must be fastened in the terminal blocks. (Potential danger of contact with the case) • Power supply and mains cables must be sufficiently fused. • Degree of protection I to IEC536.The non-fused protective earth connection must be connected to the FG terminal (Protection Class I). • All output wires must be rated for the power supply output current and must be connected with the correct polarity. • Sufficient cooling must be ensured. •N ever work on the power supply if power is supplied! Risk of electric arcs and electrical shock, which can cause death, severe personal injury or substantial property damage. •W arning: Hazardous voltages and components storing a very substantial amount of energy are present in this power supply during normal operating conditions. However, these are inaccessible. Improper handling may result in an electric shock or serious burns! Do not open the power supply until at least 5 minutes after it has been disconnected from the mains on all poles. • Only trained personnel may open the power supply. • Do not introduce any objects into the power supply. The output voltage adjustment potentiometer may only be actuated using an insulated screwdriver. • Keep away from fire and water 2
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Create Date : 2016:04:20 09:15:14-04:00 Metadata Date : 2016:04:20 09:20:54-04:00 Modify Date : 2016:04:20 09:20:54-04:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Instance ID : uuid:f7b504f7-8300-424b-9be4-e7e87b7c829b Original Document ID : xmp.did:EA3D3524EA06E611A60CE9D11C6056F8 Document ID : xmp.id:a264d1c4-d087-6f4c-8863-16f7da832aec Rendition Class : proof:pdf History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2016:04:20 09:15:14-04:00 Derived From Instance ID : xmp.iid:3c597508-0970-4643-86df-dc9760080e8f Derived From Document ID : xmp.did:EA3D3524EA06E611A60CE9D11C6056F8 Derived From Original Document ID: xmp.did:EA3D3524EA06E611A60CE9D11C6056F8 Derived From Rendition Class : default Format : application/pdf Title : Rhino PSM Series Power Supplies Installation Creator : AutomationDirect Producer : Adobe PDF Library 11.0 Trapped : False Page Layout : SinglePage Page Count : 2 Author : AutomationDirect Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools