PX-412 Analog Voltage Output Terminal PX-412 – Two-channel 0 to 10 VDC Analog Output Terminal The PX-412 Analog Output Terminal provides two electrically isolated, 0 to 10 VDC outputs with 12-bit resolution, common ground potential, and Run LED status. Use with the Protos XTM I/O System. 1 5 Number of Channels 2 Output Ranges 0 to 10 VDC Resolution 12 bit Output Type Single-ended Data Format Decimal: 0-32767 6 3 4 7 8 PX-412 Protos XTM is a trademark of Automationdirect.com Incorporated Sales 800-633-0405 I/O Bus contacts PX-MOD: 4-bytes output Data Bytes Consumed PX-TCP1/TCP2: 8-bytes out/8-bytes in (not used) Output Power Source 24VDC via terminal power bus Load Consumption (from Power Terminals) None Source Load > 5kΩ (short-circuit protected) Conversion Time Approx. 1.5ms Accuracy ± 0.5 LSB linearity error, ± 0.5 LSB offset error ± 0.1% of the full scale value Current Consumption from I/O Bus (5V) 75mA Electrical Isolation 500Vms (I/O Bus/signal voltage) Heat Dissipation 1W max. Adjacent Mounting on Bus Terminals with Power Contact Yes Adjacent Mounting on Bus Terminals without Power Contact Yes Passes Terminal Bus Power No Passes PE Bus No Status Indicators 2, see LED Status chart +Output 1 1 5 2 6 +Output 2 DIN rail release tab 3 7 Ground Shield Ground 4 Shield 8 PX-412 PX-412 LED Run 1 LED Status On Off Green LED: RUN Normal Operation Watchdog error if no data transmitted within WD set time. General Specifications 2 Run LED2 R Run LED1 Operating Temperature 32° to 131°F (0° to 55°C) Storage Temperature 13° to 185°F (-25° to 85°C) Relative Humidity 5% to 95%, non-condensing Environment Air No corrosive gases permitted Mounting/Orientation Restrictions 35mm DIN rail/None Vibration conforms to EN 60068-2-6 Shock conforms to EN 60068-2-27, EN 60068-2-29 Noise Immunity conforms to EN 61000-6-2/ EN61000-6-4 Protection Class IP20 Weight 85g Dimensions (WxHxD) 12 x 100 x 68.8 mm (0.47 x 3.94 x 2.71 in) Agency Approvals UL File No. E157382, CE www.automationdirect.com LED Run 2 +O1 +O2 1 5 + Load – 2 6 GND GND 3 7 Shld Shld 4 8 Tech Support 770-844-4200 MOUNTING For system assembly, first attach a bus coupler by snapping onto 35mm DIN rail and securing into position using the DIN rail locking wheel (where applicable) located on the left side of the coupler. To add a bus terminal, insert unit onto right side of bus coupler using the tongue and groove at the top and bottom of the unit, pressing gently until it snaps onto the DIN rail. A proper connection cannot be made by sliding the units together on the DIN rail. When correctly installed, no significant gap can be seen between the attached units. Bus connection is made through the six slide contacts located on the upper right side of the units. Add up to 64 bus terminals per bus coupler, including a bus end terminal. REMOVAL A locking mechanism prevents individual units from being pulled off. For bus terminal removal, pull the orange DIN rail release tab firmly to unlatch the unit from the rail. If attached to other terminal units, slide unit forward until released. For bus couplers with locking wheels, release the DIN rail locking wheel, then pull firmly on DIN rail release tab. Insert unit using tongue and groove ntil molded guide and press gently until it becomes firmly seated on DIN rail. ra ail. Where applicable, rotate Locking Wheel to lock Bus Coupler Where applicable, rotate Locking Wheel to unlock Bus Coupler WARNING To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at 770-844-4200. This publication is based on information that was available at the time it was printed. At AutomationDirect. com® we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. WIRING CONNECTION Firmly pull DIN Rail Release Tab to unlatch unit from rail. Align tab with molded guide Wire connection is made through a spring clamp style terminal. This terminal is designed for a single-conductor solid or stranded wire. Wire connection is made by firmly pushing the screwdriver into the screwdriver slot, inserting the wire into the wire slot and removing the screwdriver, locking the wire into position. S Screwdriver Slot S IMPORTANT For complete assembly instructions and compatibility between terminals see the PX-USER-M manual available for free download at www.automationdirect.com. Wire Slot HOT SWAP NOT PERMITTED Always remove power from the system before inserting or removing bus terminals or couplers as failure to do so could cause malfunction or damage to the terminals, couplers or other connected devices. Wiring Specifications Connection Type Spring Clamp Terminals Wire Gauge / Wire Cross Section 28-14 AWG / 0.08 - 2.5mm2 Document Name Edition/Revision Date Screwdriver Width 2.5mm (0.10) such as our TW-SD-MSL-2 PX-412-DS 1st ED. 9/15/2014 Wire Stripping Length 8mm Copyright 2014, AutomationDirect.com Incorporated/All Rights Reserved Worldwide. Sales 800-633-0405 www.automationdirect.com Tech Support 770-844-4200
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.5-c014 79.151481, 2013/03/13-12:09:15 Create Date : 2014:10:17 12:48:42-04:00 Metadata Date : 2014:10:17 12:48:47-04:00 Modify Date : 2014:10:17 12:48:47-04:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:d871d6c7-fb52-4382-95b0-9b8982a08263 Original Document ID : xmp.did:06b75c21-d8c7-3847-b0b3-63eb93780eb6 Document ID : xmp.id:d2e5434a-99fa-6648-9667-bdf5d254c940 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:4ac2bad5-d956-934b-9489-0eb5b308659f Derived From Document ID : xmp.did:8f39d9ec-4968-264d-b449-a637bab39d63 Derived From Original Document ID: xmp.did:06b75c21-d8c7-3847-b0b3-63eb93780eb6 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:10:17 12:48:42-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools