C More EA7 Quick Start Guide View / The (EA7 Series) Qsg
User Manual: View / the C-more (EA7 Series) Quick Start Guide C-more Touch Panel (EA7 Series) Quick Start Guide
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
4 Before you begin... ® Minimum items required to create a working system: 3505 HUTCHINSON ROAD CUMMING, GA 30040-5860 • C-more Touch Panel - 6”, 8”, 10”, 12” or 15” model • C-more Programming Software, p/n EA-PGMSW • C-more USB Programming Cable, p/n USB-CBL-AB15 or Ethernet connectivity between PC and Touch Panel • Power source: C-more AC/DC Power Adapter, p/n EA-AC or a dedicated 24 VDC (20.4 - 28.8 VDC) switching power supply @ 1.5 A minimum • Personal computer - to run the C-more programming software • Communications Cable (serial or Ethernet) – to connect the C-more Touch Panel to your controller Quick Start Guide Base Feature STN and TFT displays 6” STN grayscale EA7-S6M-R 6” grayscale EA7-S6M Full Feature TFT displays 8 1 15 9 Pin Signal Pin 1 Frame GND 6 LE Signal Pin 11 Signal 2 TXD (232C) 7 CTS (232C) 12 TXD– (422/485) 3 RXD (232C) 8 RTS (232C) 13 Term. Resistor TXD+ (422/485) 4 Future 9 RXD+ (422/485) 14 do not use 5 Logic GND 10 RXD– (422/485) 15 do not use Setting Adjust Clock Adjust Display Adjust Touch Panel Beeper Main Menu Unpack and Inspect MAIN MENU Temporary Support Stand Ethernet 10/100 Base-T PLC Communications, Programming/Download Audio Line Out, stereo, 1 Volt rms, 3.5mm Mini Jack (Amplifier Required) Pin Cutout Template located here. USB Port - Type B Programming/Download Mounting Clips and DC power connector located in here. Pin USB Port - Type A USB Device Options Signal 1 Vbus 2 D– 3 D+ 4 GND Pin 2 1 3 4 1 2 3 4 1 Vbus 2 D– 3 4 Shell Shield Signal Signal Pin Adjust Clock Time Signal TD+ 5 do not use 2 TD– 6 RD– 3 RD+ 7 do not use 4 do not use 8 do not use Test Menu 09 - 01 - 2005 Memory 12 Exit 8 Link Status LED (Green) Date 10 : 45 : 23 1 1 Setting Information 9 3 Network Activity LED (Orange) D+ On Ethernet Linked On Active Network Data GND Off No Ethernet Comm. Off Network Idle 6 OK Cancel SHELL Shield Note: Device is not available on Base Feature touch panels, part numbers EA7-S6M-R and EA7-T6CL-R. 6” color EA7-T6CL AC/DC Power Adapter EA-AC 8” color EA7-T8C Expansion Assembly EA-EXP-OPT Note: Use USB Programming Cable, p/n USB-CBL-AB15. 9 10” color EA7-T10C Shipping Carton Contents Full Feature and very large TFT displays 6“ & 8” Touch Panel – Temporary Stand 15” color EA7-T15C General Description The C-more® series of Touch Panels provides excellent capabilities and expanded features with their enhanced graphical programming software, rugged hardware, and convenient accessories. Engineered into the product design to provide excellent hardware and software are features such as those listed below. Some features are not available on the base feature panels. • Analog touch screen (no touch cell boundaries) • Plenty of memory and methods to get data in/out of the panel • Overlapping active devices on the screen • 65,536 colors for enhanced graphics • Screen resolutions up to 1024 X 768 pixels • Built-in project simulation, test on PC while developing • Serial RS232, RS422/485 and Ethernet 10/100Base-T communications • Programming via USB or Ethernet (Ethernet on full feature only.) • Optional AC/DC Power Adapter (EA-AC) • User replaceable bezels on 8”, 10”, 12” & 15” panels • Animation of bitmaps and objects • PID face plate, trending, alarming and a recipe database • 4,000 built-in symbols, classic fonts: 6x8, 8x16, 8x32, 8x64, 16x16, 16x32, 16x64, 32x16, 32x32, 32x64, and Windows fonts • Event Manager to trigger actions based on assigned state changes, schedules, PLC tag names, etc., setup in a database environment. The event can also trigger a sound byte, initiate a screen capture, send a data file (FTP), send an E-mail, etc. • Select unique background for each screen • Trend Data logging • Built-in FTP client/server, E-mail client, and Web server • Internet Remote Access • Audio output port, stereo – requires amplifier and speaker(s) 2 1 3 4 Shipping Carton Packing Material 6 5 7 6 10”, 12“ & 15” Touch Panel – Temporary Stand Accessories (sold separately) CF Card Interface Module: EA-CF-IF CompactFlash Memory Card: EA-CF-CARD 3 Non glare 12 inch screen cover: EA-12-COV2 (pk of 3) PC C-more Touch Panel 4 6 5 Non glare 6 inch screen cover: EA-6-COV2 (pk of 3) Safety Information WARNING: To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at 1-800-633-0405 or 770-844-4200. This publication is based on information that was available at the time it was printed. At Automationdirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without obligation. This publication may also discuss features that may not be available in certain revisions of the product. ® Ethernet Port 3 Compact Flash Memory Card EA-CF-CARD NOTE: CompactFlash memory card designations – CF Slot #1 is at the top of the panel and CF Slot #2 is the CF Card Interface Module, p/n EA-CF-IF. C-more Touch Panel CF card plugs into slot #1 at top of panel CF card interface module installs in right slot only, left slot for future ✔ C UL R US Copyright 2005-2014, Automationdirect.com Incorporated/All Rights Reserved Worldwide Productivity 3000 EA-90-30-CBL MITSUBISHI FX Series 25-pin port (RS-422A) EA-MITSU-CBL DL05/DL06 MITSUBISHI FX Series 8-pin mini-DIN (RS-422A) EA-MITSU-CBL-1 DL105 OMRON Host Link C200 Adapter, C500 (RS-232C) EA-OMRON-CBL CLICK all H0-ECOM/H0-ECOM100 all D2-230 D2-240 D2-250/D2-250-1/D2-260 NOTE: EZTouch serial PLC communication cables are compatible with C-more touch panels. EA-2CBL-1 D2-240/D2-250-1/D2-260 Using DCM H2-ECOM/H2-ECOM100 D3-330/330P (Requires the use of a Data Communications Unit) D3-340 AutomationDirect DL305 Direct LOGIC D3-350 DL405 D4-450 Ethernet Port H4-ECOM/H4-ECOM100 H2-WinPLC (Think & Do) Live V5.2 or later and Studio any version H2-WinPLC (Think & Do) Live V5.5.1 or later and Studio V7.2.1 or later (Bottom View) DF1 Full Duplex DF1 Half Duplex; DF1 Full Duplex EtherNet/IP Server EtherNet/IP Client Modbus TCP/IP SNPX FX Direct Q CPU QnA Serial QnA Ethernet Host Link FINS Modbus RTU PPI ISO over TCP AutomationDirect Prod. 3000 Serial AutomationDirect Prod. 3000 Ethernet AutomationDirect Modbus (CLICK) K-Sequence Direct NET Modbus (Koyo addressing) Direct LOGIC Ethernet K-Sequence K-Sequence K-Sequence Direct NET K-Sequence Direct NET Modbus (Koyo addressing) Direct NET Modbus (Koyo addressing) Direct LOGIC Ethernet Direct NET D4-440 10 7 NOTE: Refer to the individual product data sheets that are included with the accessories for additional information. Expansion Assembly EA-EXP-OPT AC/DC Power Adapter EA-AC Provide Power to the Touch Panel • Wire a dedicated 24 VDC (20.4 - 28.8 VDC) power source rated at a minimum of 1.5 Amps to the DC connector on the rear of the C-more touch panel, include wiring the ground terminal to a proper equipment ground. The recommended power supply is AutomationDirect P/N: PS24-050D • or install a C-more AC/DC Power Adapter, p/n EA-AC, to the rear of the touch panel and wire an AC voltage source of 100-240 VAC, 50/60Hertz, to its AC connector • then turn on the power source and check the LED status indicators on the rear of the C-more touch panel for proper indication DC Wiring Recommended DC Supply Fuse Panel Size Rating 6“ – 10” 2.5 A 12“ & 15” 4.0 A ADC p/n MDL2-5 MDL4 + Serial 24 VDC, -15%, +20% (20.4 - 28.8 VDC) Direct NET K-Sequence Direct NET Modbus (Koyo addressing) Direct NET Modbus (Koyo addressing) K-Sequence Direct NET K-Sequence Direct NET K-Sequence Direct NET Modbus (Koyo addressing) Direct NET Modbus (Koyo addressing) Direct LOGIC Ethernet Think & Do Modbus RTU (serial port) Think & Do Modbus TCP/IP (Ethernet port) C-more Touch Panel Ethernet Port (Bottom View) Ethernet CAT5 Cable - Crossover DL06 PLC Ethernet via Hub or Switch (such as SE-SW5U) – H0-ECOM/H0-ECOM100 Ethernet Module PWR Equipment Ground EA-AC AC Wiring Ethernet via Crossover Cable H0-ECOM/H0-ECOM100 Ethernet Module Stride™ Ethernet Switch 10/100 Base-T C-more Touch Panel DL-06 PLC CPU USB Pen Drive SDCZ4-2048-A10 Connect Touch Panel to PLC • Connect the serial communications cable between the C-more touch panel and the PLC • or connect the C-more touch panel and PLC together via an Ethernet hub or switch, and Ethernet cables (full feature panels only) • or use an Ethernet crossover cable directly between the C-more Ethernet port and the PLC Ethernet port (full feature panels only) GND BATT Port 2 C-more Touch Panel 1 C-more to Direct LOGIC VGA 15-pin port serial cable p/n EA-2CBL-1 Ethernet Port (Bottom View) DL06 PLC Serial Port Adapter EA-ADPTR-4 AC Power Adapter Not recommended for use with the EA7-T15C when operating temperatures are expected to be above 40 deg C. KOYO ELECTRONICS INDUSTRIES CO., LTD. C-more LED Status Indicators Off NOTE: The C-more 6” touch panels will fit into the existing cutout of any EZTouch 6” slim bezel panel. Use the C-more 6” Adapter Plate, p/n EA-6-ADPTR, to install C-more 6” panels into existing cutouts of EZTouch 6” non-slim (rounded bezel) panels. Green Power Off PWR Normal – CPU Run State On Power On Off Power Off CPU TxD Serial Port Adapter EA-COMCON-3 Red Recommended AC Supply Fuse 3.0 A time delay, ADC p/n MDL3 Date code Country of Origin KOYO ELECTRONICS INDUSTRIES CO., LTD. EA-COMCON-3 Ethernet CAT5 Cable - Straight-thru WARNING: The AC/DC Power Adapter should not be used with the EA7-T15C touch panel when operating temperatures are expected to exceed 40 °C [104 °F]. Date code Country of Origin TERM EN61131-2 Siemens DF1 Half Duplex; DF1 Full Duplex Ethernet CAT5 Cable - Straight-thru RD+ 234884 Modicon EAPLC5-232-CBL GE 90/30, 90/70, Micro 90, VersaMax Micro 15-pin D-sub port (RS-422A) Ethernet Port C-more Touch Panel 1 CF Card Interface Module EA-CF-IF RD– Per file # E157382 Omron Ethernet via Hub or Switch (such as SE-SW5U) Install Optional Hardware Accessories (sold separately) SD+ E157382 Allen-Bradley SLC 5-03/04/05, ControlLogix, CompactLogix, FlexLogix, EA-SLC-232-CBL DF1 port (RS-232C) D4-430 Ethernet Port SD– C-more Touch Panels & Accessories Mitsubishi All with DCM GND ISO-9000 EA-MLOGIX-CBL Modbus TCP/IP GE DL205 Power LED (Green) CE Allen-Bradley MicroLogix 1000, 1100, 1200, 1400, 1500 (RS-232C) (Bottom View) CPU Status LED (Green, Orange & Red) CSA EA-4CBL-2 Ethernet CAT5 Cable - Crossover Stride™ Ethernet Switch 10/100 Base-T USB Port – Type B Programming/Download UL/CUL/CSA/CE Certification Numbers UL508 Direct LOGIC PLC 25-pin D-sub port, DL405, D3-350, DL305 DCU and all DCM’s (RS-232C) PC EA-ADPTR-4 UL/CUL Direct LOGIC DL405 PLC 15-pin D-sub EA-4CBL-1 port, DL405 (RS-232C) PC IOIOI – PLC Name EA-3CBL Allen-Bradley MicroLogix, SLC 5-01/02/03, PLC5 DH485 port (RS-232C) EA-DH485-CBL C-more Touch Panel USB-CBL-AB15 6” Adapter Plate EA-6-ADPTR Agency Approvals Direct LOGIC PLC RJ-11 port, D3-340 (RS-232C) Ethernet via Crossover Cable USB Port – Type A Non glare 10 inch screen cover: EA-10-COV2 (pk of 3) USB Pen Drive, 2 GB: SDCZ4-2048-A10 EA-2CBL-1 DH485/AIC/AIC+ D3-350 DCM USB Non glare 8 inch screen cover: EA-8-COV2 (pk of 3) NOTE: To check your computer system information, go to the Start Menu – All Programs and select Accessories, then System Tools, and finally System Information. Direct LOGIC (VGA Style) 15-pin port DL06, D2-250 (250-1), D2-260 (RS-232C) Allen-Bradley Protocols MicroLogix 1000, 1100, 1200, 1400, 1500, SLC 5-01/02/03, PLC5 MicroLogix 1000, 1100, 1200, 1400, 1500 SLC 5-03/04/05 ControlLogix™, CompactLogix™, FlexLogix™ PLC-5 ControlLogix, CompactLogix, FlexLogix - Tag Based ControlLogix, CompactLogix, FlexLogix Generic I/O Messaging ControlLogix, CompactLogix, FlexLogix - Tag Based MicroLogix 1100, 1400, SLC 5/05, both via native Ethernet port MicroLogix 1000, 1100, 1200,1400, 1500, SLC 5-03/04/05, all via ENI Adapter Modbus TCP/IP devices 90/30, 90/70, Micro 90, VersaMax Micro FX Series Q02, Q02H, Q06H, Q12H, Q25H Q, QnA Serial Q, Qna Ethernet C200 Adapter, C500 CJ1/CS1 Serial; CJ1/CS1 Ethernet 984 CPU, Quantum 113 CPU, AEG Modicon Micro Series 110 CPU: 311-xx, 411-xx, 512-xx, 612-xx S7-200 CPU, RS-485 Serial S7-200 CPU, S7-300 CPU; Ethernet Productivity3000 Serial (P3-550) Productivity3000 Ethernet (P3-550) all Insert tabs between layers Non glare 15 inch screen cover: EA-15-COV2 (pk of 3) D-SUB 15 pin to Terminal Block Adapter: EA-COMCON-3 Cable Part Number AutomationDirect CLICK, Direct LOGIC PLC RJ-12 port, DL05, DL06, DL105, DL205, D3-350, D4-450 & H2-WINPLC EA-2CBL (RS-232C) Connect Touch Panel to Computer • Connect a USB Programming Cable, p/n USB-CBL-AB15, from a USB port type A on the PC to the USB type B programming port on the C-more touch panel • or connect the C-more touch panel and PC together via an Ethernet hub or switch, and Ethernet cables (full feature panels only) • or use an Ethernet crossover cable directly between the C-more touch panel Ethernet port and the PC Ethernet port (full feature panels only) Shipping Carton Packing Material D-SUB 15 pin 90 degree Comm Port Adapter: EA-ADPTR-4 Purchased Cable Description Model 8 2 Expansion Assembly: EA-EXP-OPT Install the Software and Develop a Project Insert the supplied CD-ROM into the PC’s CD-ROM drive and follow the instructions. If you need assistance during the software installation, please refer to the supplied Software Installation Guide or call the AutomationDirect Technical Support team @ 770-844-4200. 1 6 inch Adapter Plate: EA-6-ADPTR (Used to retrofit new C-more 6” touch panel into existing EZTouch non-slim panel cutout.) PLC Compatibility Table Allen-Bradley PLC-5 DF1 port (RS-232C) A table of complete specifications for all touch panels is located on the back of this Quick Start Guide. Touch Panel and accessory dimension and mounting information is also located on the back. Please refer to the individual data sheet inserts that are included with each accessory for additional details. AC/DC Power Adapter: EA-AC 5 • Personal Computer with a 333 MHz or higher processor (CPU) clock speed recommended; Intel® Pentium/ Celeron family, or AMD® K6/Athlon/Duron family, or compatible processor recommended • Keyboard and Mouse or compatible pointing device • Super VGA color video adapter and monitor with at least 800 x 600 pixels resolution (1024 x 768 pixels recommended) 64K color minimum • 300 MB free hard-disk space • 128 MB free RAM (512 MB recommended); 512 MB free RAM (1 GB recommended) for Vista • CD-ROM or DVD drive for installing software from the CD • USB port or Ethernet 10/100 Mbps port for project transfer from software to touch panel (Ethernet port not available on -R models) • Operating System - Windows® XP Home / Professional Edition Service Pack 2 (32 bit), Windows 2000 with Service Pack 4, Windows Vista® (32 or 64 bit) or Windows 7 (32 or 64 bit) Assemble Temporary Support Stand Touch Panel to PLC Communication Protocols & Cables PLC Family Following are the minimum system requirements for running C-more Programming Software, p/n EA-PGMSW, on a PC: 2 12” color EA7-T12C CF PLC Serial Communications For Future Use • Unpack the C-more Touch Panel from its shipping carton. Included in the carton is the C-more Touch Panel, cutout template, mounting clips, temporary support stand, DC power connector, gasket, and this Quick Start Guide. • Unpack any accessories that have been ordered, such as: AC/DC Power Adapter, Expansion Assembly, CompactFlash memory, programming cable, communications cable, etc. • Inspect all equipment for completeness. If anything is missing or damaged, immediately call the AutomationDirect® returns department @ 1-800-633-0405. Full Feature STN displays Compact Flash memory slot #1 is located at the top of panel. Accessing the Touch Panel Setup Screens • Access the Main Menu of the touch panel setup screens by pressing the extreme upper left corner of the panel display area for three (3) seconds as shown below. • Adjust the time and date for the panel by pressing the Setting button on the Main Menu, then press the Adjust Clock button on the Setting screen. • Use the right pointing arrows for the time or date display to select the unit to change. Use the up and down arrows to increment or decrement the value for the selected unit. • Press OK when done to accept the changes to the time and date that is retained in the touch panel’s battery backed memory, or press Cancel to exit the Adjust Clock setup screen without making any changes. • Press the Main Menu button on the Setting screen and then the Exit button on the Main Menu screen to return to the application screen. Bottom View 1 6” TFT color EA7-T6CL-R 8 Available Communication Ports Blinking Red Blinking Orange Blinking Green 100 - 240 VAC 50/60 Hz Tightening Torque Power supply cable torque 71 - 85 oz-in (0.5 - 0.6 Nm) Mounting flange screw torque 57 - 71 oz-in (0.4 - 0.5 Nm) Memory Error RxD BATT Operating System not found LCD Backlight Failure Serial TxD/RxD LED (Green) IOlOl–PLC Power Loss Detection On Comm. is active Off No communication Rear View Additional Help and Support • For product support, specifications, and installation troubleshooting, a Hardware User Manual can be downloaded from the On-line Documentation area of the AutomationDirect Web site or purchased through the AutomationDirect Sales team @ 1-800-633-0405 as part number EA-USER-M. • For software programming help, refer to the C-more Programming Software on-line embedded help. • Refer to demos of the product at: http://c-more.automationdirect.com/software/software_demo.html • For additional technical support and questions, call our Technical Support team @ 1-800-633-0405 or 770-844-4200. Data Sheet: EA-QSG, Rev. P Model Specification 6” STN grayscale w/ base features 6” TFT color w/ base features 6” STN grayscale w/ full features 6” TFT color w/ full features 8” TFT color w/ full features 10” TFT color w/ full features 12” TFT color w/ full features 15” TFT color w/ full features EA7-S6M-R EA7-T6CL-R EA7-S6M EA7-T6CL EA7-T8C EA7-T10C EA7-T12C EA7-T15C 5.7” STN grayscale 15 shades of gray 5.7” TFT color 65,536 colors 5.7” STN grayscale 15 shades of gray 5.7” TFT color 8.4” TFT color 10.4” TFT color 65,536 colors 12.1” TFT color 15.0” TFT color 6.73” x 5.05” [170.9 mm x 128.2 mm] 8.31” x 6.24” [211.2 mm x 158.4 mm] 9.47” x 7.62” [240.6 mm x 184.5 mm] 11.97” x 8.98” [304.1 mm x 228.1 mm] Part Number Display Actual Size and Type Color Scale Display Viewing Area 4.54” x 3.4” [115.2 mm x 86.4 mm] Screen Pixels Display Brightness LCD Panel Dot Pitch Backlight Average Lifetime*1 Backlight User Replaceable Touch Panel Type 320 x 240 (QVGA) 2 640 x 480 (VGA) 2 150 cd/m (NITS) 2 270 cd/m (NITS) 150 cd/m (NITS) 0.36 mm x 0.36 mm CPU Type 2 2 270 cd/m (NITS) 300 cd/m (NITS) 0.267 mm x 0.267 mm Approximately 50,000 hours No Analog Resistive (10-bit resolution, 1024 x 1024 touch area) 32-Bit RISC CPU (333 MHz) Battery System Memory System Flash Memory Backup Memory (SRAM) Logging Data Memory Number of Screens Realtime Clock Calendar – Month/Day/Year Screen Saver Serial PLC Interface USB Port – Type B USB Port – Type A Ethernet Port Audio Line Out CF Card – Slot #1 Expansion Assembly (p/n EA-EXP-OPT) Supply Power Power Consumption Recommended DC Supply Fuse Operating Temperature Storage Temperature Humidity Noise Immunity Withstand Voltage Insulation Resistance Vibration Shock Environment Enclosure Agency Approvals USB Pen Drive p/n SDCZ4-2048-A10 (Optional) not available not available not available 2 270 cd/m (NITS) 0.33 mm x 0.33 mm 7.402 [188.0] Gasket 1.500 [38.1] 0.197 [5.0] 6.140 [156.0] 5.458 [138.6] 32-Bit RISC CPU (400 MHz) Plus Graphic Accelerator Chip Replaceable battery – ADC Part # D2-BAT-1 (Manufacturer Part # CR2354) SDRAM 32 MBytes SDRAM 64 MBytes FLASH 32 MBytes FLASH 64 MBytes Control data backup memory (SRAM) 256 KBytes CompactFlash Memory Card p/n EA-CF-CARD, industrial grade, high speed (Optional) or USB Pen Drive p/n SDCZ4-2048-A10 (Optional) Up to 9999 with ver. 2.40 and later – limited by available project memory (10 MBytes) Up to 9999 with ver. 2.40 and later – limited by available project memory (40 MBytes) Built into panel (PLC clock is still accessible if available) Yes - battery backup Yes, backlight turns off after a 30–1500 minute adjustable time, or can be disabled Serial PLC Port: RS-232C/422/485 15-Pin D-sub (female) Download/Program – USB Port – type B Port for USB 1.1 device options – type A Ethernet 10/100 Base-T Audio Line Out, 1 Volt rms, stereo – requires amplifier and speaker(s) Optional: CompactFlash Memory Card p/n EA-CF-CARD, CF slot #1 located on top side of touch panel. 1.46 lb. [660 g] 1.43 lb. [650 g] 1.48 lb. [670 g] 1.50 lb. [680 g] 2.60 lb. [1,180 g] 3.55 lb. [1,610 g] 4.59 lb. [2,080 g] 11.820 [300.2] Gasket Gasket 1.738 [44.1] 1.685 [42.8] Units: inches[mm] 0.315 [8.0] NOTE: The C-more 10” touch panel will fit into the existing cutout of any EZTouch 10” touch panel. Mounting Clip (6) places 10.894 [276.7] 8.748 [222.2] 0.394 [10.0] Units: inches [mm] 13.661 [347.0] Mounting Clip (6) places 6.993 [177.6] 10.669 [271.0] 8.828 [224.2] NOTE: The C-more 8” touch panel will fit into the existing cutout of any EZTouch 8” touch panel. 15” Touch Panel Dimensions – EA7-T15C 14.892 [378.3] 12” Touch Panel Dimensions – EA7-T12C Gasket 1.654 [42.0] 12.430 [315.7] NOTE: The C-more 15” touch panel will fit into the existing cutout of any EZTouch 15” touch panel. Units: inches[mm] 16.748 [425.4] 9 W @ 24 VDC Dimensions 10” Touch Panel Dimensions – EA7-T10C 9.159 [232.6] NOTE: The C-more 6” touch panels will fit into the existing cutout of any EZTouch 6” slim bezel panel. Use the C-more 6” Adapter Plate, EA-6-ADPTR, to install C-more 6” panels into existing cutouts of EZTouch 6” non-slim (rounded bezel) panels. 0.394 [10.0] Optional: Use the CF Card Interface Module p/n EA-CF-IF in the right slot of the Expansion Assembly for installing CF card - Slot #2. The left slot of the Expansion Assembly is for future options. 8” Touch Panel Dimensions – EA7-T8C EA7-S6M-R EA7-T6CL-R EA7-S6M EA7-T6CL 8.047 [204.4] 24 VDC, -15%, +20% (20.4–28.8 VDC operating range p/n PS24-050D) (Use an AC Power Adapter, p/n EA-AC, to power the touch panel from a 100-240 VAC, 50/60 Hz. power source.) 10 W @ 24 VDC 11 W @ 24 VDC 15 W @ 24 VDC 17 W @ 24 VDC 20 W @ 24 VDC 33 W @ 24 VDC 2.5 A time delay, ADC p/n MDL2-5 4.0 A time delay, ADC p/n MDL4 0 to 50 °C (32 to 122 °F); Maximum surrounding air temperature rating: 50 °C (122 °F) –20 to +60 °C (–4 to +140 °F) 10–85% RH, non-condensing Noise voltage: 1000 Vp-p, Pulse width: 1 µs, Rise time: 1 ns 1000 VDC for 1 minute, between DC power supply input terminal and safety ground Over 20 M⏲ between DC power supply input terminal and safety ground IEC61131-2 compliant, 10–57 Hz: 0.075 mm amplitude, 57–150 Hz 1.0 G: 10 sweep cycles per axis on each of 3 mutually perpendicular axes 15 G peak, 11 ms duration, 2 shocks per axis, on 3 mutually perpendicular axes For use in Pollution Degree 2 Environment Meets UL Type 4X, when mounted correctly. For indoor use only. UL, cUL, CE 8.748” x 10.894” x 2.053” 10.669” x 13.661” x 2.079” 11.024” x 13.366” x 2.075” 13.000” x 16.748” x 2.048” 6.140” x 8.047” x 1.697” [156.0 mm x 204.4 mm x 43.1 mm] [222.2 mm x 276.7 mm x 52.1 mm] [271.0 mm x 347.0 mm x 52.8 mm] [280.0 mm x 339.5 mm x 52.7 mm] [330.2 mm x 425.4 mm x 52.0 mm] 9 W @ 24 VDC Mounting Clip (2) places Units: inches[mm] 1024 x 768 (XGA) 220 cd/m2 (NITS) 0.297 mm x 0.297 mm Analog Resistive (12-bit resolution, 4096 x 4096 touch area) 32-Bit RISC CPU (400 MHz) not available Weight 800 x 600 (SVGA) 260 cd/m2 (NITS) 0.267 mm x 0.267 mm 6” Touch Panel Dimensions 1.681 [42.7] 0.394 [10.0] Mounting Clip (8) places Units: inches [mm] Mounting Clip (6) places 13.366 [339.5] 11.230 [285.2] 13.000 [330.2] Gasket 10.088 [256.2] 11.024 [280.0] 7.01 lb. [3,180 g] * NOTE 1: The backlight average lifetime is defined as the average usage time it takes before the brightness becomes 50% of the initial brightness. The lifetime of the backlight depends on the ambient temperature. The lifetime will decrease under low or high temperature usage. EA7-S6M-R EA7-T6CL-R EA7-S6M EA7-T6CL 7.460 +0.04 -0.0 [189.5 +1.0 -0.0] 0.630 [16.0] Mounting Clip Screw Torque 0.315 [8.0] 0.294 [7.5] 0.294 [7.5] 5.512 +0.04 -0.0 [140.0 +1.0 -0.0 ] NOTE: The C-more 6” touch panels will fit into the existing cutout of any EZTouch 6” slim bezel panel. Use the C-more 6” Adapter Plate, p/n EA-6-ADPTR, to install C-more 6” panels into existing cutouts of EZTouch 6” non-slim (rounded bezel) panels. Enclosure Mounting Thickness Range and Mounting Clip Screw Torque Mounting Clip (2) places 0.315 [8.0] Enclosure Mounting Thickness Range CUTOUT Bezel Outline Touch Panel Size Enclosure Thickness Range Mounting Clip Screw Torque 6” – lower mounting clip position 0.039 - 0.24 inch [1 – 6 mm] 35 ~ 50 oz-in [0.25 ~ 0.35 Nm] 6” – upper mounting clip position 0.20 - 0.63 inch [5 – 16 mm] 35 ~ 50 oz-in [0.25 ~ 0.35 Nm] 8”, 10”, 12” & 15” 0.039 - 0.20 inch [1 – 5 mm] 42 ~ 57 oz-in [0.3 ~ 0.4 Nm] Mounting Clearances 0.630 [16.0] 6.533 [165.9] 0.709 [18.0] 0.118 ±0.04 [3.0 ±1.0] 7.299 [185.4] M4 Thread Insert (6 places) Adapter Front View 14.960 +0.04 -0.0 [380.0 +1.0 -0.0 ] 7.480 [190.0] 0.894 [22.7] 0.406 [10.3] Screw NOTE: Refer to the product data sheet, EA-6-ADPTR-DS, that is included with the adapter plate for additional information. C-more Adapter Plate 11.276 +0.04 -0.0 [286.4 +1.0 -0.0 ] CUTOUT 7.075 +0.04 -0.0 [179.7 +1.0 -0.0 ] 5.624 [142.8] 3.111 [79.0] Units: inches[mm] Product Label EA-CF-IF 3.024 [76.8] 1.618 [41.1] 2.067 [52.5] Enclosure Units: inches [mm] EA-CF-IF Units: inches [mm] Connector Cover NOTE: The CF Card Interface Module must be installed in the right slot of the Expansion Assembly. Refer to the product data sheet, EA-CF-IF-DS, that is included with the module for additional information. DIN Mounting Clips 2.812 [71.4] 3.761 [95.5] 5.638 [143.2] BOTTOM VIEW 0.780 [19.8] 2.122 [53.9] 3.567 [90.6] Cutout Outline 3.537 [89.9] Units: inches [mm] 0.579 [14.7] Two sets of mounting screws provided: Set A - M4-8 metric screws for an enclosure thickness range of 0.02-0.118 inch [0.5-3mm] Set B - M4-10 metric screws for an enclosure thickness range of 0.118-0.197 inch [3-5mm] Mounting screw torque: 100 oz-in [0.7 Nm] Centerline 6.222 [158.0] 0.837 [21.3] NOTE: Refer to the product data sheet, EA-AC-DS, that is included with the power adapter for additional information. Expansion Assembly Dimensions EA-EXP-OPT 6“ C-more Touch Panel 0.837 [21.3] 1.421 [36.1 ±0.5] 2.165 [55.0] Adapter Plate Outline 0.218 Dia. [5.5] (6 places) CF Card Interface Module Dimensions Rear View Mounting Details 2.125 [54.0] 0.864 [21.9] DC Power Connector SIDE VIEW Units: inches [mm] Gasket Cutout Dimensions 0.394 [10.0] CUTOUT Units: inches [mm] FRONT VIEW Side View 8.076 [205.1] 4.250 [108.0] Mounting Clip (6) places Cutout Outline 6.223 ±0.02 [158.1 ±0.5] Centerline NOTE: The adapter plate has been designed to simplify the retrofit of a new C-more 6” touch panel into an existing cabinet cutout for an EZTouch 6” non-slim touch panel, such as our part number EZ-S6C-K, EZ-S6C-F, EZ-S6M-R or EZ-S6M-F. The new C-more 6” touch panel will directly mount into the existing cutout opening for any EZTouch 6” slim touch panel. The adapter plate gasket is included. 0.395 [10.0] Mounting Clip (8) places CUTOUT NOTE: The AC/DC Power Adapter allows Power Fault features to help protect data being logged to CompactFlash during power failures. The C-more touch panel must have firmware version 1.21 Build 6.18E or higher for proper operation. ±0.02 0.395 [10.0] 0.822 [20.9] WARNING: The AC/DC Power Adapter should not by used with the EA7-T15C touch panel when operating temperatures are expected to exceed 40 °C [104 °F]. 3.661 [93.0] AC Power Connector NOTE: The mounting clearances when installing the touch panel in an enclosure or cabinet should be kept to a minimum of 4 inches from the top, bottom and sides and 2 inches from the rear. 0.394 [10.0] 4.625 [117.5] AC Power Label Screw 3.001 [76.2] 0.709 [18.0] 6” Touch Panel Cutout 9.250 +0.04 -0.0 [235.0 +1.0 -0.0] AC/DC Power Adapter Dimensions – EA-AC 8.076 ±0.02 [205.1 ±0.5] 4.250 ±0.02 [108.0 ±0.5] 0.618 [15.7] Units: inches[mm] Units: inches[mm] 0.822 [20.9] Bezel Outline 8.932 [226.9] Cutout Outline 0.894 [22.7] 0.394 [10.0] 6” Adapter Plate Dimensions – EA-6-ADPTR 0.705 [17.9] 0.837 [21.3] 7.522 [191.1] 0.705 [17.9] NOTE: Refer to the product data sheet, EA-EXP-OPTDS, that is included with the expansion assembly for additional information. Screw Torque: 100 oz-in [0.7 Nm] 0.459 [11.7] Bezel Outline Screw Replacement Parts 0.354 [9.0] 8 - 15 inch mounting clips: EA-BRK-2 (pk of 8) 0.394 [10.0] DC power connector: EA-DC-CON Mounting Clip (6) places CUTOUT 0.394 [10.0] AC power connector: EA-AC-CON 12 inch backlight: EA-12-BULB EA-12-BULB2 10 inch backlight: EA-10-BULB EA-10-BULB2 8 inch backlight: EA-8-BULB EA-8-BULB2 10.236 [260.0 8.917 +0.04 -0.0 [226.5 +1.0 -0.0 ] Cutout Outline Units: inches [mm] 4.459 [113.2] Units: inches [mm] 5.118 [130.0] ] *CAUTION - The battery used in this device may present a risk of fire or chemical burn if mistreated. Do not recharge, disassemble, heat above 100 °C (212 °F) or incinerate. Replace battery with AutomationDirect part number D2-BAT-1 or CR2354 only. Use of another battery may present a risk of fire or explosion. Dispose of used battery properly. Keep away from children. Cutout Outline Bezel Outline Units: inches[mm] EA7-S6M = 2.921 [74.2] EA7-T6CL = 2.921 [74.2] EA7-T8C = 3.157 [80.2] EA7-T10C = 3.106 [78.9] EA7-T12C = 3.102 [78.8] EA7-T15C = 3.075 [78.1] X.XXX [XX.X] Units: inches[mm] 15-Pin Serial Port Adapters - Dimensions 6 inch Adapter Plate replacement gasket EA-6-ADPTR-GSK +0.04 -0.0 +1.0 -0.0 with Expansion Assembly, EA-EXP-OPT EA7-S6M-R = 2.921 [74.2] EA7-T6CL-R = 2.921 [74.2 EA7-S6M = 2.921 [74.2] EA7-T6CL = 2.921 [74.2] EA7-T8C = 3.157 [80.2] EA7-T10C = 3.106 [78.9] EA7-T12C = 3.102 [78.8] EA7-T15C = 3.075 [78.1] 6 - 15 inch Bezels: EA-6-BEZEL EA-8-BEZEL EA-10-BEZEL EA-12-BEZEL EA-15-BEZEL (gasket not included) Note: 6 inch bezel is not user replaceable. CUTOUT with AC/DC Power Adapter, EA-AC NOTE: The EA-ADPTR-4 adapter is plugged into the 15-pin serial port on the rear of the panel to allow a PLC communication cable to be plugged in at a 90 degree angle to reduce panel depth requirements. NOTE: The EA-COMCON-3 adapter is plugged into the 15-pin serial port on the rear of the panel to allow wire terminal connections for RS-422/485 PLC communication cable. Date code Country of Origin KOYO ELECTRONICS INDUSTRIES CO., LTD. EA-COMCON-3 Date code 1.605 [40.8] 0.394 [10.0] X.XXX [XX.X] 6 - 15 inch gaskets: EA-6-GSK EA-8-GSK EA-10-GSK EA-12-GSK EA-15-GSK TERM 6 inch mounting clips: EA-BRK-1 (pk of 2) 15 inch backlight: EA-15-BULB EA-15-BULB2 RD+ ] Touch Panel Overall Depth with Accessories Installed Battery: D2-BAT-1 RD– 0.354 [9.0] 6.289 [159.7] 0.394 [10.0] 0.877 [22.3] 0.876 [22.3] Mounting Clip (6) places 12.579 [319.5 +0.04 -0.0 +1.0 -0.0 0.406 [10.3] SD+ 0.394 [10.0] ] 5.954 [151.2] 0.877 [22.3] 0.354 [9.0] 0.864 [21.9] SD– 11.908 [302.5 15” Touch Panel Cutout – EA7-T15C GND 0.394 [10.0] +0.04 -0.0 +1.0 -0.0 0.837 0.394 [21.3] [10.0] 1.756 [44.6] 8” Touch Panel Cutout – EA7-T8C Country of Origin KOYO ELECTRONICS INDUSTRIES CO., LTD. EA-ADPTR-4 Perchlorate Material, special disposal handling may apply. Bezel Outline 10” Touch Panel Cutout – EA7-T10C 0.876 [22.3] 0.394 [10.0] 12” Touch Panel Cutout – EA7-T12C 0.394 [10.0] 0.354 [9.0] AVERTISSEMENT : La pile utilisée dans ce dispositif pourrait présenter un risque d’incendie ou de brûlure chimique si traitée inadéquatement. Ne pas recharger la pile, ne pas la démonter, ne pas la chauffer au-delà de 100 °C (212 °F) ni l’incinérer. Remplacez la pile uniquement par la pièce n° D2-BAT-1 (CR2354) d’AutomationDirect.com. L’emploi de toute autre pile peut présenter un risque d’incendie ou d’explosion. Jeter la pile usagée adéquatement. Tenir hors de portée des enfants. IOIOI – PLC 1.873 [47.6] 1.126 [28.6] EA-COMCON-3 R 1.873 [47.6] 0.793 [20.2] EA-ADPTR-4 R
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : Acrobat Distiller 11.0 (Windows) GTS PDFX Conformance : PDF/X-1a:2001 GTS PDFX Version : PDF/X-1:2001 Trapped : False Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2014:08:14 11:11:44-04:00 Create Date : 2014:08:14 11:09:37-04:00 Metadata Date : 2014:08:14 11:11:44-04:00 Format : application/pdf Title : C-more EA7 Quick Start Guide Creator : AutomationDirect Description : C-more EA7 Series Panels Quick Start Guide Version ID : 1 Document ID : uuid:4d323b17-6ebc-404f-957a-bbe5a22db863 Instance ID : uuid:2595d204-5b3b-45d3-bf82-f47ccd2cfcd2 Page Count : 2 Author : AutomationDirect Subject : C-more EA7 Series Panels Quick Start Guide Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools