Cisco UCS 5108 Blade Server Chassis Spec Sheet 51 C17 644224

User Manual: UCS-51

Open the PDF directly: View PDF PDF.
Page Count: 46

DownloadCisco UCS 5108 Blade Server Chassis Spec Sheet UCS-51 C17-644224
Open PDF In BrowserView PDF
Spec Sheet

Cisco UCS 5108
Blade Server Chassis

CISCO SYSTEMS
170 WEST TASMAN DR.
SAN JOSE, CA, 95134
WWW.CISCO.COM

PUBLICATION HISTORY
REV A.17

FEBRUARY 1, 2018



CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Chassis Front Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fabric Extender Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fabric Interconnect Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

....
....
....
....

...
...
...
...

....
....
....
....

. . .5
. . .7
. . .8
. . .9

BASE CHASSIS STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 10
CONFIGURING the CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STEP
STEP
STEP
STEP
STEP
STEP
STEP

1 VERIFY BASE CHASSIS SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2 SELECT FABRIC I/O EXTENDERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
3 SELECT FABRIC INTERCONNECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
4 CHOOSE ADDITIONAL COMPONENTS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 18
5 CHOOSE POWER SUPPLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6 SELECT INPUT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Smart Net Total Care (SNTC) for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service . . . . . . . . . . . . . 27
Solution Support for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Smart Net Total Care for UCS Hardware Only Service . . . . . . . . . . . . . . . . . . . . . . . 29
Partner Support Service for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PSS is available to all Cisco PSS partners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PSS for UCS Hardware Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Unified Computing Combined Support Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
UCS Drive Retention Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Local Language Technical Support for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Cisco UCS and Blade Server Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5108 Blade Chassis Server Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Blade Chassis Connection Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Connectivity Cisco 6324 Fabric Interconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Fabric Extender Bundles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Physical Dimensions and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46

Cisco UCS 5108 Blade Server Chassis

2

OVERVIEW

OVERVIEW
The UCS 5108 chassis is a 6RU chassis the that can accommodate up to eight half-width, four full-width or
any combination of blade form factors (M1 - M5 generation) that will fit in the available number of blade
slots. The chassis has two I/O bays for Fabric Extenders or Fabric Interconnects.
Figure 1 through Figure 3 on page 4 show the front and rear views of a 5108 blade chassis.

Figure 1

Cisco UCS 5108 Blade Server Chassis (front view)

Figure 2

Cisco UCS 5108 Blade Server Chassis with Fabric Extenders (rear view)

Cisco UCS 5108 Blade Server Chassis

3

OVERVIEW

Figure 3

4

Cisco UCS 5108 Blade Server Chassis with Fabric Interconnects (rear view)

Cisco UCS 5108 Blade Server Chassis

DETAILED VIEWS

DETAILED VIEWS
Chassis Front Views
Figure 4 is a detailed front view of the Cisco UCS 5108 Blade Server Chassis with eight half-width blade
servers installed.
Figure 4

5108 Chassis Front View with Eight Half-Width Blade Servers Installed

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Power Supply 1

Power Supply 2

Power Supply 3

Power Supply 4

Table 1 Front View Callouts
Callout

Description

Slot 1 - 8

Slot numbering for half-width blade servers

Power Supply 1 - 4

Slot numbering for power supply

Cisco UCS 5108 Blade Server Chassis

5

DETAILED VIEWS

Figure 5 is a detailed front view of the Cisco UCS 5108 Blade Server Chassis with four full-width blade
servers installed.
Figure 5

5108 Chassis Front View with Four Full-Width Blade Servers Installed

Slot 1

Slot 2

Slot 3

Slot 4

Power Supply 1

Power Supply 2

Power Supply 3

Power Supply 4

Table 2 Front View Callouts
Callout

Description

Slot 1 - 4

Slot numbering for full-width blade servers

Power Supply 1 - 4

Slot numbering for power supply

NOTE: If a B460 M4 full-width blade server is mixed with other full-width or
half-width blades in the chassis, the B460 M4 must occupy the bottom two full-width
slots in the 5108 blade chassis.

6

Cisco UCS 5108 Blade Server Chassis

DETAILED VIEWS

Chassis Rear View
Figure 6 shows the rear view of the 5108 chassis (AC power version).
Figure 6

Chassis Rear View (AC power supplies)

Fabric Extender 1

Fabric Extender 2
Fan #1

Power Supply 4
Fan #5

Cisco UCS 5108 Blade Server Chassis

Fan #2

Power Supply 3
Fan #6

Fan #3

Power Supply 2

Fan #4

Power Supply 1
Fan #7

Fan #8

7

DETAILED VIEWS

Fabric Extender Modules
The Fabric Extender modules (up to two) plug into the back of the UCS 5108 blade chassis. A midplane
connects the blade servers to the Fabric Extenders. The 5108 blade chassis accommodates the following
Fabric Extender modules:


Cisco UCS 2208XP



Cisco UCS 2204XP



Cisco UCS 2304

Figure 7 shows the Fabric Extenders.
Figure 7

2208XP, 2204XP, and 2304 Fabric Extender

Status LED
Status LED

Status LED

4 x 10 GbE
Unified Fabric Ports
and LEDs
4 x 40 GbE
Unified Fabric Ports
and LEDs

8 x 10 GbE
Unified Fabric Ports
and LEDs

2208XP Fabric Extender

8

2204XP Fabric Extender

2304 Fabric Extender

Cisco UCS 5108 Blade Server Chassis

DETAILED VIEWS

Fabric Interconnect Module
The Fabric Interconnect modules (up to two) plug into the back of the 5108 blade chassis. A midplane
connects the blade servers to the Fabric Interconnects. The 5108 blade chassis accommodates the following
Fabric Interconnect module:


Cisco UCS 6324 Fabric Interconnect
NOTE: The Cisco UCS 6324 is supported only in the UCSB-5108-AC2 and
UCSB-5108-DC2 chassis. The Cisco UCS 6324 is not currently supported in the
UCSB-5108-HVDC chassis.

Figure 8 shows the Fabric Interconnect.
Figure 8

Cisco UCS 6324 Fabric Interconnect

Ethernet management port

USB port

Four SFP+ ports

One QSFP+ licensed port

Console port

Cisco UCS 5108 Blade Server Chassis

9

BASE CHASSIS STANDARD CAPABILITIES and FEATURES

BASE CHASSIS STANDARD CAPABILITIES and FEATURES
Table 3 lists the capabilities and features of the base 5108 chassis. Details about how to configure the
chassis for a particular feature or capability are provided in CONFIGURING the CHASSIS on page 12.
Table 3 Capabilities and Features
Capability/Feature
Management by Cisco
UCS Manager

Unified fabric
Support for up to two
Cisco UCS 2200 or 2300
Series Fabric Extenders

Support for up to two
Cisco UCS 6324 Fabric
Interconnects that
connect directly to an
external switch
Auto-discovery

High-performance
mid-plane

Redundant
hot-swappable power
supplies and fans

10

Description


Reduces TCO by removing management modules from the chassis,
making the chassis stateless, and UCS systems management inherently
scalable



Provides a single, highly available management domain for all system
chassis, reducing administrative tasks through automated service profile
configuration

Decreases TCO by reducing the number of network interface cards (NICs),
host bus adapters (HBAs), switches, and cables needed


Eliminates switches from the chassis along with complex configuration
and management of those switches, allowing a system to scale without
adding complexity and cost



Allows use of two fabric extenders for redundancy or aggregation of
bandwidth



Enables bandwidth scaling based on application needs; blades can be
configured for 1.25 Gbps to 40 Gbps



Allows use of up to two internal 6324 fabric interconnects for
redundancy or aggregation of bandwidth



The 6324 Fabric Interconnect combines the Fabric Extender and Fabric
Interconnect functions into one plug-in module, and allows direct
connection to an external switch.

Requires no configuration; like all components in the Cisco Unified
Computing System, chassis are automatically recognized and configured by
Cisco UCS Manager and its service profiles and service profile groups


Provides investment protection



Supports up to 2x 40 Gbit Ethernet links to each half-width blade slot
or up to 4x 40 Gbit links to each full-width slot



Provides 8 blades with 1.2 terabits (Tb) of available Ethernet
throughput for future I/O requirements. (note that the UCS 6324 FI
supports only 512 Gbps)



Provides reconfigurable chassis to accommodate a variety of form
factors and functions



Provides high availability in multiple configurations



Provides uninterrupted service during maintenance

Cisco UCS 5108 Blade Server Chassis

BASE CHASSIS STANDARD CAPABILITIES and FEATURES

Table 3 Capabilities and Features (continued)
Capability/Feature

Description

Hot-swappable blade
servers and fabric
extenders

Provides uninterrupted service during maintenance and server deployment.

Comprehensive
monitoring
Thermal efficiencies

Tool-free installation



Provides extensive environmental monitoring on each chassis



Allows use of user thresholds to optimize environmental management of
the chassis

The Chassis Management Controller (CMC) monitors all the temperature
sensors and regulates fan speeds to maintain the airflow at the minimum
needed to cool the system. The open backplane and deep plenum allow air
to be directed across the blades to ensure cooling is directed where it is
needed most.


Requires no specialized tools for chassis installation



Provides mounting rails for easy installation and servicing

Mixed blade
configurations

The UCS 5108 Server Chassis can accommodate a maximum of 8 half-width
sever blades or 4 full-width server blades or any combinations of the two
sizes that will fit in the chassis.

UCS Manager

Consult Cisco UCS Hardware and Software Compatibility tool at
https://ucshcltool.cloudapps.cisco.com/public/ to verify supported
hardware and software combinations.

Cisco UCS 5108 Blade Server Chassis

11

CONFIGURING the CHASSIS

CONFIGURING the CHASSIS
Follow these steps to configure the Cisco UCS 5108 chassis:

12



STEP 1 VERIFY BASE CHASSIS SKU, page 13



STEP 2 SELECT FABRIC I/O EXTENDERS, page 15



STEP 3 SELECT FABRIC INTERCONNECTS, page 17



STEP 4 CHOOSE ADDITIONAL COMPONENTS (OPTIONAL), page 18



STEP 5 CHOOSE POWER SUPPLIES, page 24



STEP 6 SELECT INPUT POWER CORD(s), page 25



STEP 7 CHOOSE SERVICE and SUPPORT LEVEL, page 26



SUPPLEMENTAL MATERIAL on page 34

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

STEP 1

VERIFY BASE CHASSIS SKU

Verify the product ID (PID) of the base 5108 blade chassis as shown in Table 4. Note that you can
order either an AC, -48 DC, or high-voltage DC (200 VDC—380 VDC) input power version of the
chassis.
Table 4 PID of the Base UCS Mini Chassis
Product ID (PID)

Description

Usage

UCSB-5108-AC2

UCS 5108 Blade Server 
AC2 Chassis, 0 PSU/8 fans/0 FEX

Cannot be configured outside bundle.
Use N20-Z0001 or UCS-MINI-Z0001 PIDs
to include Fabric Interconnects, blades,
power supply Units (PSUs) and Fabric
Extender (FEX) modules as a system.

UCSB-5108-AC2-UPG

UCS 5108 Blade Server 
AC2 Chassis, 0 PSU/8 fans/0 FEX

Can only be used to order a chassis
configured with blades, PSUs and FEX or
FIOM modules. May not be used to order
an empty chassis.

UCSB-5108-AC2=

UCS 5108 Blade Server 
AC2 Chassis, 0 PSU/8 fans/0 FEX

Use to order an empty chassis with or
without PSUs and FEX or FIOM modules,
cannot be configured with blades.

UCSB-5108-DC2

UCS 5108 Blade Server DC2
Chassis/0 PSU/8 fans/0 FEX

Cannot be configured outside bundle.
Use N20-Z0001 or UCS-MINI-Z0001 PIDs
to include Fabric Interconnects, blades,
PSUs and FEX modules as a system.

UCSB-5108-DC2-UPG

UCS 5108 Blade Server DC2
Chassis/0 PSU/8 fans/0 FEX

Can only be used to order a chassis
configured with blades, PSUs and FEX or
FIOM modules. May not be used to order
an empty chassis.

UCSB-5108-DC2=

UCS 5108 Blade Server DC2
Chassis/0 PSU/8 fans/0 FEX

Use to order an empty chassis with or
without power supplies and FEX or FIOM
modules, cannot be configured with
blades.

UCSB-5108-HVDC

UCS 5108 Blade Chassis 200V-380V
HVDC 0 PSU/8 fans/0 FEX

Cannot be configured outside bundle.
Use N20-Z0001 or UCS-MINI-Z0001 PIDs
to include Fabric Interconnects, blades,
PSUs and FEX modules as a system.

UCSB-5108-HVDC-UPG

UCS 5108 Blade Chassis 200V-380V
HVDC 0 PSU/8 fans/0 FEX

Can only be used to order a chassis
configured with blades, PSUs and FEX or
FIOM modules. May not be used to order
an empty chassis.

UCSB-5108-HVDC=

UCS 5108 Blade Chassis 200V-380V
HVDC 0 PSU/8 fans/0 FEX

Use to order an empty chassis with or
without PSUs and FEX or FIOM modules,
cannot be configured with blades.

Items included with the chassis:


N01-UAC1: AC power input module (AC blade chassis only)



UCSB-PWRM-DC48: DC power input module (DC blade chassis only)

Cisco UCS 5108 Blade Server Chassis

13

CONFIGURING the CHASSIS



UCSB-PWRM-HVDC: HVDC power input module (HVDC blade chassis only)



N20-CDIVH: Horizontal divider, where quantity is based on number and type of blade(s)
selected.



N20-CDIVV: Vertical divider, where quantity is based on number and type of blade(s)
selected.



N20-CBLKI: FEX blanking panel, where quantity is based on unpopulated slots.



N20-CBLKB1: Blade blanking panel, where quantity is based on unpopulated slots.



N20-CBLKP: PSU blanking panel, where quantity is based on unpopulated slots.



N20-FAN5: Fan modules.



N20-CAK: Chassis accessory kit, consisting of:
—

N20-CRMK2: Tool-less rail kit designed for racks with square mounting.

—

N20-BKVM=: KVM local console connector cable that connects to the front of any
UCS blade server, and documentation.

Items not included with the chassis (but may be ordered separately):


N20-CRMK2-RHA=: Round hole adapter kit used to install tool-less rail kit in racks that have
round mounting holes (supports threaded and non-threaded holes).



All items listed above can be ordered separately as spares, with the exception of the power
input modules.

NOTE: The adapter kit only works with the N20-CRMK2 rail kit

Caveats

14



You must select either an AC, DC, or HVDC version of the 5108 blade chassis, which is
configured with the appropriate input power module (AC, DC or HVDC).



Mixing of AC, DC, and HVDC PSUs within the same 5108 blade chassis is not supported.



The blade chassis input power module cannot be replaced in the field to convert the input
power type, e.g. converting a DC input to an AC input blade chassis.

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

STEP 2

SELECT FABRIC I/O EXTENDERS

The Fabric I/O Extender options are:


Cisco UCS 2208XP



Cisco UCS 2204XP



Cisco UCS 2304

Choose Fabric I/O Extenders
The available Fabric I/O Extenders are listed in Table 5. Each Fabric I/O Extender connects to
the Fabric Interconnect series 10GbE or 40GbE, Fibre Channel over Ethernet (FCoE) capable
ports.
Table 5 Available Fabric I/O Extenders

Product ID (PID)

Fabric I/O Extender

Number of
Number of Internal
GbE/FCoE
Ports to Fabric GbE/FCoE Ports
Interconnect

Total
Chassis I/O
per Fabric
Extender

UCS-IOM-2304

2304

4x40G

32x10G or 8x40G

160 Gbps

UCS-IOM-2304-8FET

Bundle that includes one
2304 plus 8 Fabric Extender
Transceivers (FETs)1

4x40G

32x10G or 8x40G

160 Gbps

UCS-IOM-2208XP

2208XP

8x40G

32x10G

80 Gbs

UCS-IOM2208-16FET

Bundle that includes one
2208XP plus 16 Fabric
Extender Transceivers (FETs)1

8x40G

32x10G

80 Gbs

UCS-IOM-2204XP

2204XP

4x40G

16x10G

40 Gbs

UCS-IOM2204-8FET

Bundle that includes one
2204XP plus 8 Fabric
Extender Transceivers (FETs)1

4x40G

16x10G

40 Gbs

Notes . . .

1. For more information on Fabric Extender bundles, see Fabric Extender Bundles on page 41.

Approved Configurations
(1) Choose one or two identical Fabric I/O Extenders, or
(2) Choose one or two identical Fabric Extender bundles (includes one Fabric Extender plus
transceivers)

Cisco UCS 5108 Blade Server Chassis

15

CONFIGURING the CHASSIS

Caveats


Do not use any Fabric Extender transceivers other than those that come in the bundles.



You cannot combine a 6324 Fabric Interconnect and a Fabric Extender in the same chassis

NOTE: The Cisco UCS 2304 Fabric Extender is not compatible with the Cisco UCS
6200 Fabric Interconnect series

16

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

STEP 3

SELECT FABRIC INTERCONNECTS

The Fabric Interconnect options are:


Cisco UCS 6324 Fabric Interconnect

Choose Fabric Interconnects
The available Fabric Interconnects are listed in Table 6. Each Fabric Interconnect integrates the
functions of a Fabric I/O Extender and Fabric Interconnect and connects directly to external
Nexus switches by means of several ports of 10GbE and Fibre Channel over Ethernet (FCoE).
Table 6 Available Fabric Interconnects

Product ID (PID)

UCS-FI-M-6324

Fabric Interconnect

UCS 6324 in-chassis FI
with1 x 40G QSFP+
expansion port, and 16
10G-KR links to servers

Number of
Internal
GbE/FCoE
Ports

Number of
FCoE Uplink
Ports

Number of
40GbE/FCoE
Scalability
Ports1

Total Chassis
I/O per Fabric
Interconnect

16x10G

4x1G or 10G

1

40 Gbs
(one 40 GbE
Port)

Notes . . .

1. The scalability port supports a QSFP+ breakout cable.

Approved Configurations
(1) Choose one or two identical Fabric Interconnects
Caveats


You must select either one or two identical Fabric Interconnects.



You cannot combine a 6324 Fabric Interconnect and a Fabric Extender in the same chassis

Cisco UCS 5108 Blade Server Chassis

17

CONFIGURING the CHASSIS

STEP 4

CHOOSE ADDITIONAL COMPONENTS (OPTIONAL)

The Cisco UCS FEX and FIOM support SFP+ Ethernet transceivers, SFP transceivers, SFP+ copper Twinax
cables with integrated transceivers, SFP Fibre Channel transceivers, QSFP transceivers, and QSFP cables.
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports
that connect the blade chassis to the fabric interconnect. Each Cisco UCS 2204XP has sixteen 10 Gigabit
Ethernet ports connected through the midplane to each half-width slot in the chassis. Typically configured
in pairs for redundancy, two fabric extenders provide up to 80 Gbps of I/O to the chassis. This product
support 10 Gigabit Ethernet SFP+ copper Twinax cables for short distances and SFP+ optics for longer
distances.
The Cisco UCS 2208XP Fabric Extender (Figure 7) has eight 10 Gigabit Ethernet, FCoE-capable, Enhanced
Small Form-Factor Pluggable (SFP+) ports that connect the blade chassis to the fabric interconnect. Each
Cisco UCS 2208XP has thirty-two 10 Gigabit Ethernet ports connected through the midplane to each
half-width slot in the chassis. Typically configured in pairs for redundancy, two fabric extenders provide up
to 160 Gbps of I/O to the chassis. This product support 10 Gigabit Ethernet SFP+ copper Twinax cables for
short distances and SFP+ optics for longer distances.
The Cisco UCS 2304 Fabric Extender (Figure 7) has four 40 Gigabit Ethernet, FCoE-capable, Quad Small
Form-Factor Pluggable (QSFP+) ports that connect the blade chassis to the fabric interconnect. Each Cisco
UCS 2304 can provide one 40 Gigabit Ethernet ports connected through the midplane to each half-width slot
in the chassis, giving it a total eight 40G interfaces to the compute. Typically configured in pairs for
redundancy, two fabric extenders provide up to 320 Gbps of I/O to the chassis. This product support 40
Gigabit Ethernet QSFP+ copper Twinax cables for short distances and QSFP+ optics for longer distances.
The Cisco UCS 6324 Fabric Interconnect supports a wide variety of 10 Gigabit Ethernet connectivity options
using Cisco 10GBASE SFP+ modules. In addition, the four SFP+ uplink ports support 1 Gigabit Ethernet
connectivity options using 1GBASE SFP modules. Alternatively, 2/4/8-Gbps Fibre Channel SFP+ interfaces
are supported.
The supported transceivers and cables are shown in Table 7. Additional transceiver and cable compatibility
details for Cisco UCS products is available at:
https://www.cisco.com/c/en/us/support/interfaces-modules/transceiver-modules/products-device-suppor
t-tables-list.html
Table 7 SFP+ Transceivers
Product ID

FEX or FIOM

Description
2204

2208

2304

6324

SFP+ Transceivers
SFP-10G-SR

10GBASE-SR SFP+ module (multimode fiber
[MMF])

X

X

X

SFP-10G-SR-X

10GBASE-SR SFP+ module (multimode fiber
[MMF]) - Extended Operating Temperature
Range

X

X

X

SFP-10G-LR

10GBASE-LR SFP+ module (single-mode fiber
[SMF])

X

X

X

18

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

Table 7 SFP+ Transceivers (continued)
Product ID

FEX or FIOM

Description
2204

2208

2304

6324

SFP+ Transceivers
SFP-10G-LR-X

10GBASE-LR SFP+ module (single-mode fiber
[SMF]) - Extended Operating Temperature
Range

X

X

SFP-10G-SR-S

10GBASE-SR SFP+ module, (multi-mode fiber
[MMF]) — no FCoE support

X

X

SFP-10G-LR-S

SFP-10G-LR-S 10GBASE-LR SFP +module
(single-mode fiber [SMF]) — no FCoE support

X

X

FET-10G

FET-10G 10GBASE-FET SFP+ module
(multimode fiber [MMF])

X

X

X

SFP 1-Gigabit Transceivers
GLC-T

1000BASE-T SFP transceiver module for
Category 5 copper wire

X

GLC-TE

1000BASE-T SFP transceiver module for
Category 5 copper wire

X

GLC-LH-SM

1000BASE-LX/LH SFP transceiver module,
MMF/SMF, 1310-nm wavelength, dual LC/PC
connector

X

GLC-LH-SMD

1000BASE-LX/LH SFP transceiver module,
MMF/SMF, 1310nm, DOM

X

GLC-SX-MM

1000BASE-SX SFP transceiver module, MMF,
850nm wavelength, dual LC/PC connector

X

GLC-SX-MMD

1000BASE-SX SFP transceiver module, MMF,
850nm, DOM

X

X

X

X

QSFP Transceivers
QSFP-40G-SR4

40zGBASE-SR4 QSFP module (multimode fiber
[MMF] at 100m)

X

QSFP-40G-SR4-S

40zGBASE-SR4 QSFP module (multimode fiber
[MMF] at 100m)

X

QSFP-40G-CSR4

40GBASE Extended CSR4 QSFP module (MMF at
300m)

X

QSFP-40G-LR4

Cisco 40GBASE-LR4 QSFP+ transceiver module
for SMF, duplex LC connector

X

QSFP-40G-LR4-S

Cisco 40GBASE-LR4 QSFP+ transceiver module
for SMF, duplex LC connector

X

FET-40G

Cisco 40G Line Extender for FEX

X

Cisco UCS 5108 Blade Server Chassis

19

CONFIGURING the CHASSIS

Table 7 SFP+ Transceivers (continued)
Product ID

FEX or FIOM

Description
2204

2208

2304

6324

SFP+ Copper and Optical Cables with Integrated Transceivers
SFP-H10GB-CU1M

SFP-H10GB-CU1M 10GBASE-CU SFP+ 1-meter
cable

X

X

X

SFP-H10GB-CU3M

SFP-H10GB-CU3M 10GBASE-CU SFP+ 3-meter
cable

X

X

X

SFP-H10GB-CU5M

SFP-H10GB-CU5M 10GBASE-CU SFP+ 5-meter
cable

X

X

X

SFP-H10GB-ACU7M

SFP-H10GB-ACU7M 10GBASE-CU SFP+ 7-meter
cable

X

X

X

SFP-H10GB-ACU10M

SFP-H10GB-ACU10M 10GBASE-CU SFP+
10-meter cable

X

X

X

SFP-10G-AOC1M

SFP-10G-AOC1M 10GBASE Active Optical SFP+
Cable, 1M

X

X

X

SFP-10G-AOC3M

SFP-10G-AOC3M 10GBASE Active Optical SFP+
Cable, 3M

X

X

X

SFP-10G-AOC5M

SFP-10G-AOC5M 10GBASE Active Optical SFP+
Cable, 5M

X

X

X

SFP-10G-AOC7M

SFP-10G-AOC5M 10GBASE Active Optical SFP+
Cable, 7M

X

X

X

SFP-10G-AOC10M

SFP-10G-AOC5M 10GBASE Active Optical SFP+
Cable, 10M

X

X

X

QSFP Cables with Integrated Transceivers
QSFP-4x10G-AC7M

Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ direct-attach breakout cable, 7-meter,
active

X

X

QSFP-4x10G-AC10M

Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ direct-attach breakout cable, 10-meter,
active

X

X

QSFP-H40G-CU1M

Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 1-meter, passive

X

QSFP-H40G-CU3M

Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 3-meter, passive

X

QSFP-H40G-CU5M

Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 5-meter, passive

X

QSFP-H40G-ACU7M

Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 7-meter, active

X

20

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

Table 7 SFP+ Transceivers (continued)
Product ID

FEX or FIOM

Description
2204

2208

2304

6324

QSFP Cables with Integrated Transceivers
QSFP-H40G-ACU10M

Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 10-meter, active

X

QSFP-4SFP10G-CU1M

Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ passive direct-attach copper transceiver
assembly, 1 meter

X

X

QSFP-4SFP10G-CU3M

Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ passive direct-attach copper transceiver
assembly, 3 meter

X

X

QSFP-4SFP10G-CU5M

Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ passive direct-attach copper transceiver
assembly, 5 meter

X

X

QSFP-4X10G-AOC1M

Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 1-meter

X

X

QSFP-4X10G-AOC3M

Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 3-meter

X

X

QSFP-4X10G-AOC5M

Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 5-meter

X

X

QSFP-4X10G-AOC7M

Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 7-meter

X

X

QSFP-4X10G-AOC10M

Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 10-meter

X

X

Fibre Channel SFP Transceiver (Cisco UCS 6324 Fabric Interconnect)
DS-SFP-FC4G-SW

4 Gbps Fibre Channel-SW SFP, LC connector

X

DS-SFP-FC4G-LW

4 Gbps Fibre Channel-LW SFP, LC, (10km
Reach)

X

DS-SFP-FC8G-SW

8-Gbps Fibre Channel SW SFP+, LC connector

X

DS-SFP-FC8G-LW

8 Gbps Fibre Channel LW SFP+, LC

X

Cisco UCS 5108 Blade Server Chassis

21

CONFIGURING the CHASSIS

Table 8 Cabling specifications
Connector (Media)

Cable Type

Distance

Power

Standard

SFP+ copper CU

Twinax

1, 3, 5, 7 and 10 m

0.1W

SFF 8431

SFP+ FET

MM OM2

25 and 100 m

1.0W

IEEE 802.3ae

82 and 300 m

1.0W

IEEE 802.3ae

MM OM3
MM OM4
SFP+ short-reach (SR) and
multimode fiber (MMF)

MM OM2
MM OM3
MM OM4

SFP+ long-reach (LR) MMF and
SR

SMF

Up to 300 m

1.0W

IEEE 802.3ae

QSFP+ copper CU

Twinax

1, 3, 5, 7 and 10 m

0.1W

SFF 8635

QSFP+ FET

MM OM2

30 and 100 m

1.5W

IEEE 802.3ba

30 and 300 m

1.5W

IEEE 802.3ba

Up to 300 m

3.5W

IEEE 802.3ba

MM OM3
MM OM4
QSFP+ short-reach (SR) and
multimode fiber (MMF)

MM OM2
MM OM3
MM OM4

QSFP+ long-reach (LR) MMF and
SR

SMF

Choose QSFP+ Port License
In order to use the QSFP+ port on 6324 FI, a license must be added. See Table 9.
Table 9 QSFP+ Port License
Product ID (PID)

PID Description

UCS-6324-40G

Mini FI License for 40G Scalability Port

Caveats

22



You should order enough SFPs, QSFPs and cables to accommodate your maximum
foreseeable needs.



If you selected a QSFP+ transceiver, make sure you choose a QSFP+ port license.



For the 6324, observe the following:

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

—

The maximum number of SFP+ transceivers, SFP optical transceivers, copper
transceivers, or Twinax cables must be less than or equal to four. A minimum of one
of these must be installed for the 6324 to have network connectivity.

—

The maximum number of Fibre Channel SFPs must be less than or equal to three.
The reason for this is that at least one SFP+ port on the 6324 must be free so the
6324 can connect to a network.

Cisco UCS 5108 Blade Server Chassis

23

CONFIGURING the CHASSIS

STEP 5

CHOOSE POWER SUPPLIES

The 5108 blade chassis accommodates up to four power supplies.
Choose Power Supplies
The available power supplies are listed in Table 10.
Table 10 Available Power Supplies
Product ID (PID)

PID Description

UCSB-PSU-2500ACDV

2500 W Platinum AC Hot Plug Power Supply - DV

UCSB-PSU-2500DC48

2500 W DC -48 V power supply

UCSB-PSU-2500HVDC

2500 W DC high voltage (200 to 380 VDC) DC power supply

Approved Configurations
(1) Choose from 2 to 4 power supplies
Caveats

24



You must select either an AC, DC, or HVDC version of the 5108 blade chassis, which is
configured with the appropriate input power module (AC, DC or HVDC).



Mixing AC, DC or HVDC PSUs within the same 5108 blade chassis is not supported.



The blade chassis input power module cannot be replaced in the field to convert the input
type e.g. converting a DC input to an AC input blade chassis.

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

STEP 6

SELECT INPUT POWER CORD(s)

Select the appropriate AC power cords listed in Table 11. You may select up to 4 power cords.
Table 11 Available Power Cords
Product ID (PID)

PID Description

Comment

CAB-AC-16A-AUS

16A, 250 VAC

Australia

UCSB-CABL-C19-BRZ

16A, 250 VAC

Brazil

CAB-AC16A-CH

16A, 250 VAC

China

CAB-AC-2500W-EU

16A, 250 VAC

Europe

CAB-AC-2500W-INT

16A, 250 VAC

International

CAB-AC-2500W-ISRL

16A, 250 VAC

Israel

CAB-US620P-C19-US

16A, 250VAC

USA

NEMA L6-20P to IEC C19
CAB-AC-C6K-TWLK

20A, 250VAC

USA

NEMA L6-20 (Twist Lock) to IEC C19
CAB-ACS-16

16A, 250 VAC

Switzerland

CAB-C19-CBN

16A, 250 VAC

Jumper cord C19/C20

CAB-US515P-C19-US

15A, 125 VAC
NEMA 5-15 to IEC-C19

USA

CAB-US520-C19-US

20A, 125 VAC
NEMA 5-20 to IEC-C19

USA

CAB-BS1363-C19-UK

13A, 250 VAC

UK

BS1363 to IEC C19
CAB-9K16A-KOR

16A, 250 VAC

South Korea

CEE 7/7 to IEC C19
CAB-C19-C20-3M-JP

16A, 250 VAC

Japan

CAB-IR2073-C19-AR

20A, 250 VAC

Argentina

IRSM 2073 to IEC C19
CAB-SABS-C19-IND

16A, 250 VAC

India

SABS 164-1 to IEC C19
CAB-S132-C19-ISRL

16A, 250 VAC

Isreal

S132 to IEC C19
CAB-C2316-C19-IT

16A, 250 VAC

Italy

CEI 23-16 to IEC C19

Cisco UCS 5108 Blade Server Chassis

25

CONFIGURING the CHASSIS

STEP 7

CHOOSE SERVICE and SUPPORT LEVEL

A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is
supplied:


Three-year parts coverage.



Next business day (NBD) onsite parts replacement eight hours a day, five days a week.



90-day software warranty on media.



Ongoing downloads of BIOS, drivers, and firmware updates.



UCSM updates for systems with Unified Computing System Manager. These updates include
minor enhancements and bug fixes that are designed to maintain the compliance of UCSM
with published specifications, release notes, and industry standards.

Smart Net Total Care (SNTC) for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This
service provides expert software and hardware support to help sustain performance and high availability of
the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around
the clock, from anywhere in the world.
For the 5108 chassis, there is Smart Call Home, which provides proactive, embedded diagnostics and
real-time alerts. For systems that include Unified Computing System Manager, the support service includes
downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement
options, including replacement in as little as two hours. There is also access to Cisco's extensive online
technical resources to help maintain optimal efficiency and uptime of the unified computing environment.
You can choose a desired service listed in Table 12.
Table 12 Cisco SNTC for UCS Service (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-PREM-6508AC2

C2P

Yes

SNTC 24X7X2OS

CON-UCSD8-6508AC2

UCSD8

Yes

UC SUPP DR 24X7X2OS*

CON-C2PL-6508AC2

C2PL

Yes

LL 24X7X2OS**

CON-OSP-6508AC2

C4P

Yes

SNTC 24X7X4OS

CON-UCSD7-6508AC2

UCSD7

Yes

UCS DR 24X7X4OS*

CON-C4PL-6508AC2

C4PL

Yes

LL 24X7X4OS**

CON-USD7L-6508AC2

USD7L

Yes

LLUCS HW DR

CON-OSE-6508AC2

C4S

Yes

SNTC 8X5X4OS

CON-UCSD6-6508AC2

UCSD6

Yes

UC SUPP DR 8X5X4OS*

26

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

Table 12 Cisco SNTC for UCS Service (PID UCSB-5108-AC2)
CON-SNCO-6508AC2

SNCO

Yes

SNTC 8x7xNCDOS****

CON-OS-6508AC2

CS

Yes

SNTC 8X5XNBDOS

CON-UCSD5-6508AC2

UCSD5

Yes

UCS DR 8X5XNBDOS*

CON-S2P-6508AC2

S2P

No

SNTC 24X7X2

CON-S2PL-6508AC2

S2PL

No

LL 24X7X2**

CON-SNTP-6508AC2

SNTP

No

SNTC 24X7X4

CON-SNTPL-6508AC2

SNTPL

No

LL 24X7X4**

CON-SNTE-6508AC2

SNTE

No

SNTC 8X5X4

CON-SNC-6508AC2

SNC

No

SNTC 8x7xNCD****

CON-SNT-6508AC2

SNT

No

SNTC 8X5XNBD

CON-SW-6508AC2

SW

No

SNTC NO RMA

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-PREM-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-PREM-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix (Example:
*Includes Drive Retention (see below for full description)
**Includes Local Language Support (see below for full description) – Only available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan
****Available in China Only

Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service
An enhanced offer over traditional Smart Net Total Care which provides onsite troubleshooting expertise to
aid in the diagnostics and isolation of hardware issue within our customers’ Cisco Unified Computing System
(UCS) environment. It is delivered by a Cisco Certified field engineer (FE) in collaboration with remote TAC
engineer and Virtual Internet working Support Engineer (VISE). You can choose a desired service listed in
Table 13.
Table 13 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-OSPT-6508AC2

OSPT

Yes

24X7X4OS Trblshtg

CON-OSPTD-6508AC2

OSPTD

Yes

24X7X4OS TrblshtgDR*

Cisco UCS 5108 Blade Server Chassis

27

CONFIGURING the CHASSIS

Table 13 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-5108-AC2)
CON-OSPTL-6508AC2

OSPTL

Yes

24X7X4OS TrblshtgLL**

CON-OPTLD-6508AC2

OPTLD

Yes

24X7X4OS TrblshtgLLD***

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-OSPT-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-OSPT-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix (Example:
*Includes Drive Retention (see below for full description)
**Includes Local Language Support (see below for full description) – Only available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan

Solution Support for UCS
Solution Support includes both Cisco product support and solution-level support, resolving complex issues in
multivendor environments, on average, 43% more quickly than product support alone. Solution Support is a
critical element in data center administration, to help rapidly resolve any issue encountered, while
maintaining performance, reliability, and return on investment.
This service centralizes support across your multivendor Cisco environment for both our products and
solution partner products you’ve deployed in your ecosystem. Whether there is an issue with a Cisco or
solution partner product, just call us. Our experts are the primary point of contact and own the case from
first call to resolution. For more information please refer to the following url:
http://www.cisco.com/c/en/us/services/technical/solution-support.html?stickynav=1
You can choose a desired service listed in Table 14.
Table 14 Solution Support for UCS Service (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-SSC2P-6508AC2

SSC2P

Yes

SOLN SUPP 24X7X2OS

CON-SSC4P-6508AC2

SSC4P

Yes

SOLN SUPP 24X7X4OS

CON-SSC4S-6508AC2

SSC4S

Yes

SOLN SUPP 8X5X4OS

CON-SSCS-6508AC2

SSCS

Yes

SOLN SUPP 8X5XNBDOS

CON-SSDR7-6508AC2

SSDR7

Yes

SSPT DR 24X7X4OS*

CON-SSDR5-6508AC2

SSDR5

Yes

SSPT DR 8X5XNBDOS*

CON-SSS2P-6508AC2

SSS2P

No

SOLN SUPP 24X7X2

CON-SSSNP-6508AC2

SSSNP

No

SOLN SUPP 24X7X4

28

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

Table 14 Solution Support for UCS Service (PID UCSB-5108-AC2)
CON-SSSNE-6508AC2

SSSNE

No

SOLN SUPP 8X5X4

CON-SSSNC-6508AC2

SSSNC

No

SOLN SUPP NCD**

CON-SSSNT-6508AC2

SSSNT

No

SOLN SUPP 8X5XNBD

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON- SSC2P-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-SSC2P-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)
**Available in China only

Smart Net Total Care for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty,
Cisco offers the Cisco Smart Net Total Care for UCS Hardware Only Service. You can choose from two levels of
advanced onsite parts replacement coverage in as little as four hours. Smart Net Total Care for UCS
Hardware Only Service provides remote access any time to Cisco support professionals who can determine if
a return materials authorization (RMA) is required. You can choose a desired service listed in Table 15.
Table 15 SNTC for UCS Hardware Only Service (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-UCW7-6508AC2

UCW7

Yes

UCS HW 24X7X4OS

CON-UCWD7-6508AC2

UCWD7

Yes

UCS HW+DR 24X7X4OS*

CON-UCW7L-6508AC2

UCW7L

Yes

LL UCS 24X7X4OS**

CON-UWD7L-6508AC2

UWD7L

Yes

LL UCS DR 24X7X4OS***

CON-UCW5-6508AC2

UCW5

Yes

UCS HW 8X5XNBDOS

CON-UCWD5-6508AC2

UCWD5

Yes

UCS HW+DR 8X5XNBDOS*

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-UCW7-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-UCW7-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)

Cisco UCS 5108 Blade Server Chassis

29

CONFIGURING the CHASSIS

Table 15 SNTC for UCS Hardware Only Service (PID UCSB-5108-AC2)
**Includes Local Language Support (see below for full description) – Only available in China and Japan
***Includes Local Language Support and Drive Retention – Only available in China and Japan

Partner Support Service for UCS
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is designed for
partners to deliver their own branded support and managed services to enterprise customers. Cisco PSS
provides partners with access to Cisco's support infrastructure and assets to help them:


Expand their service portfolios to support the most complex network environments



Lower delivery costs



Deliver services that increase customer loyalty

PSS options enable eligible Cisco partners to develop and consistently deliver high-value technical support
that capitalizes on Cisco intellectual assets. This helps partners to realize higher margins and expand their
practice.

PSS is available to all Cisco PSS partners.
The two Partner Unified Computing Support Options include:


Partner Support Service for UCS



Partner Support Service for UCS Hardware Only

PSS for UCS provides hardware and software support, including triage support for third party software,
backed by Cisco technical resources and level three support. You can choose a desired service listed in
Table 16.
Table 16 PSS for UCS (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-PSJ8-6508AC2

PSJ8

Yes

UCS PSS 24X7X2 OS

CON-PSJ7-6508AC2

PSJ7

Yes

UCS PSS 24X7X4 OS

CON-PSJD7-6508AC2

PSJD7

Yes

UCS PSS 24X7X4 DR*

CON-PSJ6-6508AC2

PSJ6

Yes

UCS PSS 8X5X4 OS

CON-PSJD6-6508AC2

PSJD6

Yes

UCS PSS 8X5X4 DR*

CON-PSJ4-6508AC2

PSJ4

No

UCS SUPP PSS 24X7X2

CON-PSJ3-6508AC2

PSJ3

No

UCS SUPP PSS 24X7X4

CON-PSJ2-6508AC2

PSJ2

No

UCS SUPP PSS 8X5X4

30

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

Table 16 PSS for UCS (PID UCSB-5108-AC2)
CON-PSJ1-6508AC2

PSJ1

No

UCS SUPP PSS 8X5XNBD

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-PSJ7-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-PSJ7-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)

PSS for UCS Hardware Only
PSS for UCS Hardware Only provides customers with replacement parts in as little as two hours and provides
remote access any time to Partner Support professionals who can determine if a return materials authorization
(RMA) is required. You can choose a desired service listed in Table 17.
Table 17 PSS for UCS Hardware Only (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-PSW7-6508AC2

PSW7

Yes

UCS W PSS 24X7X4 OS

CON-PSWD7-6508AC2

PSWD7

Yes

UCS W PSS 24X7X4 DR*

CON-PSW6-6508AC2

PSW6

Yes

UCS W PSS 8X5X4 OS

CON-PSWD6-6508AC2

PSWD6

Yes

UCS W PSS 8X5X4 DR*

CON-PSW4-6508AC2

PSW4

No

UCS W PL PSS 24X7X2

CON-PSW3-6508AC2

PSW3

No

UCS W PL PSS 24X7X4

CON-PSW2-6508AC2

PSW2

No

UCS W PL PSS 8X5X4

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-PSW7-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-PSW7-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)

Cisco UCS 5108 Blade Server Chassis

31

CONFIGURING the CHASSIS

Unified Computing Combined Support Service
Combined Services makes it easier to purchase and manage required services under one contract. SNTC
services for UCS help increase the availability of your vital data center infrastructure and realize the most
value from your unified computing investment. The more benefits you realize from the Cisco Unified
Computing System (Cisco UCS), the more important the technology becomes to your business. These services
allow you to:


Optimize the uptime, performance, and efficiency of your UCS



Protect your vital business applications by rapidly identifying and addressing issues



Strengthen in-house expertise through knowledge transfer and mentoring



Improve operational efficiency by allowing UCS experts to augment your internal staff
resources



Enhance business agility by diagnosing potential issues before they affect your operations



You can choose a desired service listed in Table 18.

Table 18 Combined Support Service for UCS (PID UCSB-5108-AC2)
Service SKU

Service Level GSP

On Site?

Description

CON-NCF2P-6508AC2

NCF2P

Yes

CMB SVC 24X7X2OS

CON-NCF4P-6508AC2

NCF4P

Yes

CMB SVC 24X7X4OS

CON-NCF4S-6508AC2

NCF4S

Yes

CMB SVC 8X5X4OS

CON-NCFCS-6508AC2

NCFCS

Yes

CMB SVC 8X5XNBDOS

CON-NCF2-6508AC2

NCF2

No

CMB SVC 24X7X2

CON-NCFP-6508AC2

NCFP

No

CMB SVC 24X7X4

CON-NCFE-6508AC2

NCFE

No

CMB SVC 8X5X4

CON-NCFT-6508AC2

NCFT

No

CMB SVC 8X5XNBD

CON-NCFW-6508AC2

NCFW

No

CMB SVC SW

Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-NCF2P-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-NCF2P-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix (Example:CON-NCF2P-6508HVDU)

UCS Drive Retention Service
With the Cisco Unified Computing Drive Retention Service, you can obtain a new disk drive in exchange for
a faulty drive without returning the faulty drive.

32

Cisco UCS 5108 Blade Server Chassis

CONFIGURING the CHASSIS

Sophisticated data recovery techniques have made classified, proprietary, and confidential information
vulnerable, even on malfunctioning disk drives. The Drive Retention service enables you to retain your
drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any
potential liabilities. This service also enables you to comply with regulatory, local, and federal
requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you might
want to consider one of the Drive Retention Services listed in the above tables (where available)

NOTE: Cisco does not offer a certified drive destruction service as part of this
service.

Local Language Technical Support for UCS
Where available, and subject to an additional fee, local language support for calls on all assigned severity
levels may be available for specific product(s) - see tables above.
For a complete listing of available services for Cisco Unified Computing System, see the following URL:
http://www.cisco.com/en/US/products/ps10312/serv_group_home.html

Cisco UCS 5108 Blade Server Chassis

33

SUPPLEMENTAL MATERIAL

SUPPLEMENTAL MATERIAL
System Overview
The Cisco Unified Computing System™ (Cisco UCS™) is a next-generation data center platform that unites
compute, network, storage access, and virtualization resources into a cohesive system designed to reduce
total cost of ownership (TCO) and increase business agility. The system integrates a low-latency, lossless
unified fabric with enterprise-class, x86-architecture servers. The system is an integrated, scalable,
multichassis platform in which all resources participate in a unified management domain.

Cisco UCS and Blade Server Access
In a multilayer data center design, you can replace core Cisco Nexus 7000 Series Switches with the Cisco
Nexus 9500 platform, or replace the core with the Cisco Nexus 9500 platform and the access layer with the
Cisco Nexus 9300 platform. You can also connect an existing Cisco Unified Computing System™ (Cisco UCS®)
and blade server access layer to Insieme hardware (Figures 9 and 10).
Figure 9

34

Classic Design Using Cisco Nexus 7000 and 5000 Series and Fabric Extenders

Cisco UCS 5108 Blade Server Chassis

SUPPLEMENTAL MATERIAL

Figure 10

Classic Design Using Cisco Nexus 7000 and 5000 Series and Fabric Extenders

Cisco UCS Fabric Extenders bring the unified fabric into the blade server enclosure, providing multiple 10 or
40 Gigabit Ethernet connections between blade servers and the fabric interconnect, simplifying diagnostics,
cabling, and management.
The Fabric Extenders extend the I/O fabric between the Cisco UCS 6200 or 6300 Series Fabric Interconnects
and the Cisco UCS 5108 Blade Server Chassis, enabling a lossless and deterministic Fibre Channel over
Ethernet (FCoE) fabric to connect all blades and chassis together. Since the fabric extender is similar to a
distributed line card, it does not perform any switching and is managed as an extension of the fabric
interconnects. This approach removes switching from the chassis, reducing overall infrastructure
complexity and enabling Cisco UCS to scale to many chassis without multiplying the number of switches
needed, reducing TCO and allowing all chassis to be managed as a single, highly available management
domain.
The Fabric Extenders also manage the chassis environment (the power supply and fans as well as the
blades) in conjunction with the fabric interconnect. Therefore, separate chassis management modules are
not required.
The Fabric Extenders fit into the back of the Cisco blade chassis. Each blade chassis can support up to two
fabric extenders, allowing increased capacity and redundancy.

Cisco UCS 5108 Blade Server Chassis

35

SUPPLEMENTAL MATERIAL

Connectivity between each unique blade and the Fabric Extenders varies according to the type of blade, its
available adapter card slots, and the type of card plugged into each slot. See the individual blade server
spec sheets for detailed connectivity information and connectivity diagrams at this link:
http://www.cisco.com/en/US/products/ps10280/products_data_sheets_list.html

36

Cisco UCS 5108 Blade Server Chassis

SUPPLEMENTAL MATERIAL

Connectivity
This section explains the connectivity between the Fabric Interconnects (FIs) and Fabric Extenders (FEX).
The Fabric Extenders are extensions of the Fabric Interconnects and act as remote line cards to form a
distributed modular fabric system. The fabric extension is accomplished through the FEX fabric link, which
is the connection between the Fabric Interconnect and the FEX.
A minimum of one connection between the FI and FEX is required to provide server connectivity. Depending
on the FEX model, subsequent connections can be up to eight links, which provides added bandwidth to the
servers.

5108 Blade Chassis Server Connectivity
For the 5100 blade chassis series, the Fabric Extender modules (up to two) plug into the back of the UCS
5108 series blade server chassis. A midplane connects the blade servers to the Fabric Extenders. The 5108
chassis accommodates the following FEXs:


Cisco UCS 2304
NOTE: The Cisco UCS 2304 Fabric Extender is not compatible with the Cisco UCS
6200 Fabric Interconnect series



Cisco UCS 2208XP



Cisco UCS 2204XP

Figure 11 shows how the FEX modules in the blade chassis connect to the FIs.
Figure 11

Connecting Blade Chassis Fabric Extenders to Fabric Interconnect Chassis
Fabric Interconnect A (6332-16UP)

192749

Fabric Interconnect B (6332-16UP)

Cisco UCS 5108 Blade Server Chassis

37

SUPPLEMENTAL MATERIAL

Blade Chassis Connection Types
In a blade chassis, the FEX fabric link (the link between the FEX and the FI) supports two different types of
connections:


Discrete Mode



Port Channel Mode

In discrete mode, a half-width server slot is pinned to a given FEX fabric link. The supported number of links
are 1, 2, 4, and 8, as shown in Figure 12. The figure shows how each FEX fabric link services a particular
slot. It is an example of four FEX fabric link connections.
Figure 12

Discrete Mode FEX Fabric Link

Blade Chassis
Blade Half-Width Slot Numbers
Slot 1

Link 1

Slot 2
Link 2

Slot 3
Slot 4
Slot 5

Fabric Extender (FEX)

Link 3

Fabric Interconnect

Slot 6
Link 4

Slot 7
Slot 8

Table 19 shows the mapping from the blade chassis server half slots to the FEX fabric links.
Table 19 Blade Chassis Slot to Link Mapping
FEX Type

Number of FEX Fabric Links
1

Server Slots 1 - 8 merged to link 1

2

Server Slots 1, 3, 5, 7 merged to link 1
Server Slots 2, 4, 6, 8 merged to link 2

Cisco UCS 2304,
Cisco UCS 2208XP, and

Half-Width Server Slot to Link

4

Cisco UCS 2204XP

Server Slots 1, 5 merged to link 1
Server Slots 2, 6 merged to link 2
Server Slots 3, 7 merged to link 3
Server Slots 4, 8 merged to link 4

Cisco UCS 2208XP only

38

8

1:1 mapping. Each half-width server slot is pinned
to a single FEX fabric link.

Cisco UCS 5108 Blade Server Chassis

SUPPLEMENTAL MATERIAL

In port channel mode, the FEX fabric links are bundled into a single logical link (see Figure 13) to provide
higher bandwidth to the servers. Depending the FEX, up to 8 links can be port-channeled.
Figure 13

FEX Fabric Links in Port Channel Mode

Blade Chassis
Blade Half-Width Slot Numbers
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5

Fabric Extender (FEX)

Fabric Interconnect

Slot 6
Slot 7
Slot 8

https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-6300-series-fabric-int
erconnects/datasheet-c78-736682.html

Cisco UCS 5108 Blade Server Chassis

39

SUPPLEMENTAL MATERIAL

Connectivity Cisco 6324 Fabric Interconnects
Figure 14 is a system diagram showing a Cisco UCS 5108 chassis with internal Cisco UCS 6324 Fabric
Interconnects connected in a system.
The Cisco 6324 Fabric Interconnect provides the management and communication backbone for Cisco UCS
Mini. The chassis, blades, and rack-mount servers that are attached to interconnects are part of a single
highly available management domain
Because it supports Cisco Unified Fabric, the 6324 Fabric Interconnect offers customers flexibility to
support LAN and storage connectivity for all servers within its domain at configuration. Typically deployed
in redundant pairs, the 6324 Fabric Interconnect delivers uniform access to both networks and storage to
facilitate a fully virtualized environment. For additional details see UCS mini at
https://www.cisco.com/c/en/us/products/servers-unified-computing/index.html#~stickynav=2
Figure 14

System Diagram (Cisco UCS 5108 Chassis with Internal Cisco UCS 6324 Fabric Interconnects)

QSFP to 10-Gbps SFP Breakout Cable

SFP 10-Gbps Cable

SFP 10-Gbps Cable

Upstream

Cisco UCS 5108 Blade Chassis with 8 servers
and 2 Cisco UCS 6324 Fabric Interconnects

Upstream

Cisco UCS 5108 Blade Chassis with 8 servers
and 2 Cisco UCS 2204 Fabric Interconnects

Cisco UCS C220 M5 Rack Server

Cisco UCS C220 M5 Rack Server

Cisco UCS C220 M5 Rack Server

Cisco UCS C240 M5 Rack Server

40

Cisco UCS 5108 Blade Server Chassis

SUPPLEMENTAL MATERIAL

Fabric Extender Bundles
You can order three kinds of Fabric Extender bundles:
UCS-IOM2208-16FET
UCS-IOM2204-8FET
UCS-IOM-2304-8FET
The bundle includes a pair of Fabric Extender Transceivers (FETS) per FEX port.
NOTE: Cables connecting the Fabric Extender to the Fabric Interconnect using your
own multimode fiber (MMF) optical cables must have the same SFP (FET-10G= or
FET-40G=) on each end. Both the Fabric Extender ports and the corresponding Fabric
Interconnect ports should implement the same SFP or QSFP; otherwise, the servers
in the blade chassis might not be discovered.
The FETs are in an SFP+ and QSFP+ form-factor and support 10 Gbps or 40 Gbps full-duplex transmissions
between the Fabric Extender and Fabric Interconnect, using your own multimode fiber (MMF) optical
cables. The reach is 25 meters using MMF OM2 optical cables and 100 meters using MMF OM3 or OM4 optical
cables.
If you do not order the bundle that includes the transceivers, you can order the transceivers separately as
spares (PIDs: = FET-10G= or FET-40G=).

Cisco UCS 5108 Blade Server Chassis

41

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS
Physical Dimensions and Specifications
Table 20 Cisco UCS 5108 Chassis Specifications
Parameter

Value

Height

10.5 in. (26.7 cm); 6 rack unit (6RU)

Width

17.5 in. (44.5 cm); fits standard 19-inch square-hole rack (or round
hole threaded or non-threaded, with optional adapter kit)

Depth

32 in. (81.2 cm)

Weight

90 lbs (40.83 kg) empty, 255 lbs (115.66 kg) fully configured

Blade server slots

8 half-width slots, 4 full-width slots, or combination of half- and
full-width slots.

IO slots (for FIs or FEXs)

2

Fabric Extenders

Compatible with 2208XP, 2204XP, and 2304XP Fabric Extenders

Fabric Interconnects

Compatible with 6324 Fabric Interconnects

Power

Four PSUs supporting N, N+1 and N+N redundancy.

Fans

8 hot-swappable fan modules supporting N+1 redundancy

Management

Managed from the Cisco UCS 6200 or 6300 Series Fabric
Interconnects by Cisco UCS Manager (redundant management when
configured with two fabric extenders or two 6324 Fabric
Interconnects)

Backplane

1.2 TB of aggregate throughput; supports 10G-KR or 40G-KR
connections for 8 half-width blades.

Regulatory compliance

Products comply with CE Markings per directives 2004/108/EC and
2006/108/EC1

Safety
EMC: Emissions

42



UCANL 60950-1



CAN/CSA-C22.2 No. 60950-1



47CFR Part 15 (CFR 47) Class A



AS/NZS CISPR22 Class A



CISPR2 2 Class A



EN55022 Class A



ICES003 Class A



VCCI Class A



EN61000-3-2



EN61000-3-3



KN22 Class A

Cisco UCS 5108 Blade Server Chassis

TECHNICAL SPECIFICATIONS

Table 20 Cisco UCS 5108 Chassis Specifications (continued)
Parameter
EMC: Immunity

Cisco UCS 5108 Blade Server Chassis

Value


EN50082-1



EN61000-6-1



EN55024



CISPR24



EN300386



KN 61000-4 Series

43

TECHNICAL SPECIFICATIONS

Power Specifications
The specifications for the various 5108 power supplies are listed in Table 21.
Table 21 Power Supply
Variable

UCSB-PSU-2500ACDV

UCSB-PSU-2500DC48

UCSB-PSU-2500HVDC

IEC320 C20

Panduit LCD4-14AF-L1

Saf-D-Grid

Input Voltage Range (V
rms)

100 to 120 and 200 to 2402

-48 to -60

200 to 380

Maximum Allowable
Input Voltage Range (V
rms)

90 to 132 and 180 to 2642

-40 to -72

180 to 400

Frequency Range (Hz)

50 to 60

DC

DC

Maximum Allowable
Frequency Range (Hz)

47 to 63

DC

DC

1300/25003

2500

2500

Input Connector

Maximum Rated Output
(W)
Nominal Input Voltage
(V rms)

100

120

208

230

-48

380

Nominal Input Current
(A rms)

14.9

12.4

13.8

12.3

59.2

7.3

Maximum Input at
Nominal Input Voltage
(W)

1444

1444

2778

2747

2840

2778

Maximum Input at
Nominal Input Voltage
(VA)

1489

1489

2863

2832

2840

2778

90

90

90

91

88

90

0.97

0.97

0.97

0.97

NA

NA

Minimum Rated
Efficiency (%)4
Minimum Rated Power
Factor4
Maximum Inrush Current
(A peak)

35

90

35

Maximum Inrush Current
(ms)

0.2

0.2

0.2

Minimum Ride-Through
Time (ms)5

12

4

12

Notes . . .

1. Barrel-type terminal with 90-degree angle, two-hole tongue, which accommodates 1/0 AWG size copper
wire. The connector tongue width is 0.81-in, the stud hole spacing is 0.63-in and hole size is 0.25-in

44

Cisco UCS 5108 Blade Server Chassis

TECHNICAL SPECIFICATIONS

2. Low line operation (100-120VAC input) only supported with 6324 Fabric Interconnect
3. Maximum rated output is limited to 1300W when operating at low-line input voltage (100-120VAC)
4. This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published
at http://www.80plus.org/for certified values and test reports
5. Time output voltage remains within regulation limits at 100% load, during input voltage dropout
For configuration-specific power specifications, use the Cisco UCS Power Calculator at:
https://ucspowercalc.cisco.com

Cisco UCS 5108 Blade Server Chassis

45

TECHNICAL SPECIFICATIONS

Environmental Specifications
The environmental specifications for the Cisco UCS 5108 blade chassis are listed in Table 22.
Table 22 UCS 5108 Blade Server Environmental Specifications
Parameter

Minimum

Operating Temperature

10°C to 35°C (50°F to 95°F) with no direct sunlight
Maximum allowable operating temperature de-rated
1°C/300 m (1°F/547 ft) above 950 m (3117 ft)

Non-operating
Temperature

-40°C to 65°C (-40°F to 149°F)

Operating Relative
Humidity

8% to 90% and 24°C (75°F) maximum dew-point temperature,
non-condensing environment

Non-Operating Relative
Humidity

5% to 93% and 33°C (91°F) maximum dew-point temperature,

Operating Altitude

0 m to 3050 m (10,000 ft)

Non-Operating Altitude

0 m to 12,000 m (39,370 ft)

Non-Operating Vibration

2.2 Grms, 10 minutes per axis on each of the three axes

Operating Shock

Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes

Non-Operating Shock

Trapezoidal, 25 G, two drops on each of six faces: 175 inches per second
each corner on bottom face drop, 90 inches per second each corner on
other five faces

Safety

UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1,
CB IEC60950-1, EN

Maximum rate of change (operating and non-operating) 20°C/hr

non-condensing environment

60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC*/CB
GB4943-1995, CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943
Immunity

Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24

Electrostatic Discharge

Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV
contact discharge without physical damage

Acoustic

46



Sound power: 68.8 dBA at ambient temperature 23° C measured using
the Dome Method



GOST MsanPiN 001-96Tested to ESD levels up to 15 kilovol

Cisco UCS 5108 Blade Server Chassis



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
Language                        : en
Page Mode                       : UseOutlines
Page Count                      : 46
Access Level                    : Customer,Guest,Silver Partner,Gold Partner,Select Partner,Partner,Employee,Premier Partner
Secondary Concept               : 
Content Type                    : cisco.com#US#preSales
Auto Play                       : No
Ia Path                         : cisco.com#Products#Cisco Products#Servers - Unified Computing#Cisco UCS B-Series Blade Servers
Modify Date                     : 2018:02:01 10:21:12-08:00
Entitlement Expression          : contains( "0,1,2,3,4,7" , $profileField[3] )
Title                           : Cisco UCS 5108 Blade Server Chassis Spec Sheet
Secondary Doctype               : 
Doc Type                        : Products Data Sheet
Document Id                     : 3c916881-23c2-48f6-a4d4-384a157b0507
Down Loadable                   : Yes
View Able                       : Desktop and Mobile
Producer                        : Acrobat Distiller 18.0 (Windows); modified using iText 2.1.7 by 1T3XT
Description                     : Cisco UCS 5108 Blade Server Chassis Spec Sheet
Fire Wall                       : No
Alfresco Doc Version            : 14.0
Creator                         : FrameMaker 2017
Campaigns                       : 
Country                         : US
Alfresco Trace ID               : workspace://SpacesStore/3c916881-23c2-48f6-a4d4-384a157b0507
Topics                          : 
Concept                         : Cisco UCS B-Series Blade Servers
Date                            : 2018-02-01T18:21:00.000Z
Create Date                     : 2018:01:31 20:29:14Z
EXIF Metadata provided by EXIF.tools

Navigation menu