Cisco UCS 5108 Blade Server Chassis Spec Sheet 51 C17 644224

User Manual: UCS-51

Open the PDF directly: View PDF PDF.
Page Count: 46

CISCO SYSTEMS PUBLICATION HISTORY
170 WEST TASMAN DR.
SAN JOSE, CA, 95134 REV A.17 FEBRUARY 1, 2018
WWW.CISCO.COM
Spec Sheet
Cisco UCS 5108
Blade Server Chassis
Cisco UCS 5108 Blade Server Chassis 2
CONTENTS
OVERVIEW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
DETAILED VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Chassis Front Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Chassis Rear View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Fabric Extender Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Fabric Interconnect Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
BASE CHASSIS STANDARD CAPABILITIES and FEATURES . . . . . . . . . . . . . . . . 10
CONFIGURING the CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
STEP 1 VERIFY BASE CHASSIS SKU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
STEP 2 SELECT FABRIC I/O EXTENDERS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
STEP 3 SELECT FABRIC INTERCONNECTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
STEP 4 CHOOSE ADDITIONAL COMPONENTS (OPTIONAL) . . . . . . . . . . . . . . . . . . . . . . . . 18
STEP 5 CHOOSE POWER SUPPLIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
STEP 6 SELECT INPUT POWER CORD(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
STEP 7 CHOOSE SERVICE and SUPPORT LEVEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Smart Net Total Care (SNTC) for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service . . . . . . . . . . . . . 27
Solution Support for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Smart Net Total Care for UCS Hardware Only Service . . . . . . . . . . . . . . . . . . . . . . . 29
Partner Support Service for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PSS is available to all Cisco PSS partners. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
PSS for UCS Hardware Only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Unified Computing Combined Support Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
UCS Drive Retention Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Local Language Technical Support for UCS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
SUPPLEMENTAL MATERIAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Cisco UCS and Blade Server Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
5108 Blade Chassis Server Connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Blade Chassis Connection Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Connectivity Cisco 6324 Fabric Interconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Fabric Extender Bundles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
TECHNICAL SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Physical Dimensions and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Power Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44
Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Cisco UCS 5108 Blade Server Chassis
OVERVIEW
3
OVERVIEW
The UCS 5108 chassis is a 6RU chassis the that can accommodate up to eight half-width, four full-width or
any combination of blade form factors (M1 - M5 generation) that will fit in the available number of blade
slots. The chassis has two I/O bays for Fabric Extenders or Fabric Interconnects.
Figure 1 through Figure 3 on page 4 show the front and rear views of a 5108 blade chassis.
Figure 1 Cisco UCS 5108 Blade Server Chassis (front view)
Figure 2 Cisco UCS 5108 Blade Server Chassis with Fabric Extenders (rear view)
Cisco UCS 5108 Blade Server Chassis
4
OVERVIEW
Figure 3 Cisco UCS 5108 Blade Server Chassis with Fabric Interconnects (rear view)
Cisco UCS 5108 Blade Server Chassis
DETAILED VIEWS
5
DETAILED VIEWS
Chassis Front Views
Figure 4 is a detailed front view of the Cisco UCS 5108 Blade Server Chassis with eight half-width blade
servers installed.
Figure 4 5108 Chassis Front View with Eight Half-Width Blade Servers Installed
Slot 1
Slot 3
Slot 5
Slot 7
Power Supply 1 Power Supply 2 Power Supply 3 Power Supply 4
Slot 2
Slot 4
Slot 6
Slot 8
Table 1 Front View Callouts
Callout Description
Slot 1 - 8 Slot numbering for half-width blade servers
Power Supply 1 - 4 Slot numbering for power supply
Cisco UCS 5108 Blade Server Chassis
6
DETAILED VIEWS
Figure 5 is a detailed front view of the Cisco UCS 5108 Blade Server Chassis with four full-width blade
servers installed.
Figure 5 5108 Chassis Front View with Four Full-Width Blade Servers Installed
Slot 1
Slot 3
Power Supply 1 Power Supply 2 Power Supply 3 Power Supply 4
Slot 2
Slot 4
Table 2 Front View Callouts
Callout Description
Slot 1 - 4 Slot numbering for full-width blade servers
Power Supply 1 - 4 Slot numbering for power supply
NOTE: If a B460 M4 full-width blade server is mixed with other full-width or
half-width blades in the chassis, the B460 M4 must occupy the bottom two full-width
slots in the 5108 blade chassis.
Cisco UCS 5108 Blade Server Chassis
DETAILED VIEWS
7
Chassis Rear View
Figure 6 shows the rear view of the 5108 chassis (AC power version).
Figure 6 Chassis Rear View (AC power supplies)
Power Supply 1Power Supply 2Power Supply 3Power Supply 4
Fabric Extender 1
Fan #1
Fabric Extender 2
Fan #5 Fan #6 Fan #7 Fan #8
Fan #2 Fan #3 Fan #4
Cisco UCS 5108 Blade Server Chassis
8
DETAILED VIEWS
Fabric Extender Modules
The Fabric Extender modules (up to two) plug into the back of the UCS 5108 blade chassis. A midplane
connects the blade servers to the Fabric Extenders. The 5108 blade chassis accommodates the following
Fabric Extender modules:
Cisco UCS 2208XP
Cisco UCS 2204XP
Cisco UCS 2304
Figure 7 shows the Fabric Extenders.
Figure 7 2208XP, 2204XP, and 2304 Fabric Extender
Status LED
8 x 10 GbE
Unied Fabric Ports
and LEDs
4 x 10 GbE
Unied Fabric Ports
and LEDs
Status LED
2208XP Fabric Extender 2204XP Fabric Extender 2304 Fabric Extender
Status LED
4 x 40 GbE
Unied Fabric Ports
and LEDs
Cisco UCS 5108 Blade Server Chassis
DETAILED VIEWS
9
Fabric Interconnect Module
The Fabric Interconnect modules (up to two) plug into the back of the 5108 blade chassis. A midplane
connects the blade servers to the Fabric Interconnects. The 5108 blade chassis accommodates the following
Fabric Interconnect module:
Cisco UCS 6324 Fabric Interconnect
Figure 8 shows the Fabric Interconnect.
Figure 8 Cisco UCS 6324 Fabric Interconnect
NOTE: The Cisco UCS 6324 is supported only in the UCSB-5108-AC2 and
UCSB-5108-DC2 chassis. The Cisco UCS 6324 is not currently supported in the
UCSB-5108-HVDC chassis.
Ethernet management port
Four SFP+ ports
One QSFP+ licensed port
USB port
Console port
Cisco UCS 5108 Blade Server Chassis
10
BASE CHASSIS STANDARD CAPABILITIES and FEATURES
BASE CHASSIS STANDARD CAPABILITIES and FEATURES
Table 3 lists the capabilities and features of the base 5108 chassis. Details about how to configure the
chassis for a particular feature or capability are provided in CONFIGURING the CHASSIS on page 12.
Table 3 Capabilities and Features
Capability/Feature Description
Management by Cisco
UCS Manager Reduces TCO by removing management modules from the chassis,
making the chassis stateless, and UCS systems management inherently
scalable
Provides a single, highly available management domain for all system
chassis, reducing administrative tasks through automated service profile
configuration
Unified fabric Decreases TCO by reducing the number of network interface cards (NICs),
host bus adapters (HBAs), switches, and cables needed
Support for up to two
Cisco UCS 2200 or 2300
Series Fabric Extenders
Eliminates switches from the chassis along with complex configuration
and management of those switches, allowing a system to scale without
adding complexity and cost
Allows use of two fabric extenders for redundancy or aggregation of
bandwidth
Enables bandwidth scaling based on application needs; blades can be
configured for 1.25 Gbps to 40 Gbps
Support for up to two
Cisco UCS 6324 Fabric
Interconnects that
connect directly to an
external switch
Allows use of up to two internal 6324 fabric interconnects for
redundancy or aggregation of bandwidth
The 6324 Fabric Interconnect combines the Fabric Extender and Fabric
Interconnect functions into one plug-in module, and allows direct
connection to an external switch.
Auto-discovery Requires no configuration; like all components in the Cisco Unified
Computing System, chassis are automatically recognized and configured by
Cisco UCS Manager and its service profiles and service profile groups
High-performance
mid-plane Provides investment protection
Supports up to 2x 40 Gbit Ethernet links to each half-width blade slot
or up to 4x 40 Gbit links to each full-width slot
Provides 8 blades with 1.2 terabits (Tb) of available Ethernet
throughput for future I/O requirements. (note that the UCS 6324 FI
supports only 512 Gbps)
Provides reconfigurable chassis to accommodate a variety of form
factors and functions
Redundant
hot-swappable power
supplies and fans
Provides high availability in multiple configurations
Provides uninterrupted service during maintenance
Cisco UCS 5108 Blade Server Chassis
BASE CHASSIS STANDARD CAPABILITIES and FEATURES
11
Hot-swappable blade
servers and fabric
extenders
Provides uninterrupted service during maintenance and server deployment.
Comprehensive
monitoring Provides extensive environmental monitoring on each chassis
Allows use of user thresholds to optimize environmental management of
the chassis
Thermal efficiencies The Chassis Management Controller (CMC) monitors all the temperature
sensors and regulates fan speeds to maintain the airflow at the minimum
needed to cool the system. The open backplane and deep plenum allow air
to be directed across the blades to ensure cooling is directed where it is
needed most.
Tool-free installation Requires no specialized tools for chassis installation
Provides mounting rails for easy installation and servicing
Mixed blade
configurations The UCS 5108 Server Chassis can accommodate a maximum of 8 half-width
sever blades or 4 full-width server blades or any combinations of the two
sizes that will fit in the chassis.
UCS Manager Consult Cisco UCS Hardware and Software Compatibility tool at
https://ucshcltool.cloudapps.cisco.com/public/ to verify supported
hardware and software combinations.
Table 3 Capabilities and Features (continued)
Capability/Feature Description
Cisco UCS 5108 Blade Server Chassis
12
CONFIGURING the CHASSIS
CONFIGURING the CHASSIS
Follow these steps to configure the Cisco UCS 5108 chassis:
STEP 1 VERIFY BASE CHASSIS SKU, page 13
STEP 2 SELECT FABRIC I/O EXTENDERS, page 15
STEP 3 SELECT FABRIC INTERCONNECTS, page 17
STEP 4 CHOOSE ADDITIONAL COMPONENTS (OPTIONAL), page 18
STEP 5 CHOOSE POWER SUPPLIES, page 24
STEP 6 SELECT INPUT POWER CORD(s), page 25
STEP 7 CHOOSE SERVICE and SUPPORT LEVEL, page 26
SUPPLEMENTAL MATERIAL on page 34
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
13
STEP 1 VERIFY BASE CHASSIS SKU
Verify the product ID (PID) of the base 5108 blade chassis as shown in Table 4. Note that you can
order either an AC, -48 DC, or high-voltage DC (200 VDC—380 VDC) input power version of the
chassis.
Table 4 PID of the Base UCS Mini Chassis
Product ID (PID) Description Usage
UCSB-5108-AC2 UCS 5108 Blade Server
AC2 Chassis, 0 PSU/8 fans/0 FEX Cannot be configured outside bundle.
Use N20-Z0001 or UCS-MINI-Z0001 PIDs
to include Fabric Interconnects, blades,
power supply Units (PSUs) and Fabric
Extender (FEX) modules as a system.
UCSB-5108-AC2-UPG UCS 5108 Blade Server
AC2 Chassis, 0 PSU/8 fans/0 FEX Can only be used to order a chassis
configured with blades, PSUs and FEX or
FIOM modules. May not be used to order
an empty chassis.
UCSB-5108-AC2= UCS 5108 Blade Server
AC2 Chassis, 0 PSU/8 fans/0 FEX Use to order an empty chassis with or
without PSUs and FEX or FIOM modules,
cannot be configured with blades.
UCSB-5108-DC2 UCS 5108 Blade Server DC2
Chassis/0 PSU/8 fans/0 FEX Cannot be configured outside bundle.
Use N20-Z0001 or UCS-MINI-Z0001 PIDs
to include Fabric Interconnects, blades,
PSUs and FEX modules as a system.
UCSB-5108-DC2-UPG UCS 5108 Blade Server DC2
Chassis/0 PSU/8 fans/0 FEX Can only be used to order a chassis
configured with blades, PSUs and FEX or
FIOM modules. May not be used to order
an empty chassis.
UCSB-5108-DC2= UCS 5108 Blade Server DC2
Chassis/0 PSU/8 fans/0 FEX Use to order an empty chassis with or
without power supplies and FEX or FIOM
modules, cannot be configured with
blades.
UCSB-5108-HVDC UCS 5108 Blade Chassis 200V-380V
HVDC 0 PSU/8 fans/0 FEX Cannot be configured outside bundle.
Use N20-Z0001 or UCS-MINI-Z0001 PIDs
to include Fabric Interconnects, blades,
PSUs and FEX modules as a system.
UCSB-5108-HVDC-UPG UCS 5108 Blade Chassis 200V-380V
HVDC 0 PSU/8 fans/0 FEX Can only be used to order a chassis
configured with blades, PSUs and FEX or
FIOM modules. May not be used to order
an empty chassis.
UCSB-5108-HVDC= UCS 5108 Blade Chassis 200V-380V
HVDC 0 PSU/8 fans/0 FEX Use to order an empty chassis with or
without PSUs and FEX or FIOM modules,
cannot be configured with blades.
Items included with the chassis:
N01-UAC1: AC power input module (AC blade chassis only)
UCSB-PWRM-DC48: DC power input module (DC blade chassis only)
Cisco UCS 5108 Blade Server Chassis
14
CONFIGURING the CHASSIS
UCSB-PWRM-HVDC: HVDC power input module (HVDC blade chassis only)
N20-CDIVH: Horizontal divider, where quantity is based on number and type of blade(s)
selected.
N20-CDIVV: Vertical divider, where quantity is based on number and type of blade(s)
selected.
N20-CBLKI: FEX blanking panel, where quantity is based on unpopulated slots.
N20-CBLKB1: Blade blanking panel, where quantity is based on unpopulated slots.
N20-CBLKP: PSU blanking panel, where quantity is based on unpopulated slots.
N20-FAN5: Fan modules.
N20-CAK: Chassis accessory kit, consisting of:
N20-CRMK2: Tool-less rail kit designed for racks with square mounting.
N20-BKVM=: KVM local console connector cable that connects to the front of any
UCS blade server, and documentation.
Items not included with the chassis (but may be ordered separately):
N20-CRMK2-RHA=: Round hole adapter kit used to install tool-less rail kit in racks that have
round mounting holes (supports threaded and non-threaded holes).
All items listed above can be ordered separately as spares, with the exception of the power
input modules.
NOTE: The adapter kit only works with the N20-CRMK2 rail kit
Caveats
You must select either an AC, DC, or HVDC version of the 5108 blade chassis, which is
configured with the appropriate input power module (AC, DC or HVDC).
Mixing of AC, DC, and HVDC PSUs within the same 5108 blade chassis is not supported.
The blade chassis input power module cannot be replaced in the field to convert the input
power type, e.g. converting a DC input to an AC input blade chassis.
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
15
STEP 2 SELECT FABRIC I/O EXTENDERS
The Fabric I/O Extender options are:
Cisco UCS 2208XP
Cisco UCS 2204XP
Cisco UCS 2304
Choose Fabric I/O Extenders
The available Fabric I/O Extenders are listed in Table 5. Each Fabric I/O Extender connects to
the Fabric Interconnect series 10GbE or 40GbE, Fibre Channel over Ethernet (FCoE) capable
ports.
Table 5 Available Fabric I/O Extenders
Product ID (PID) Fabric I/O Extender
Number of
GbE/FCoE
Ports to Fabric
Interconnect
Number of Internal
GbE/FCoE Ports
Tot al
Chassis I/O
per Fabric
Extender
UCS-IOM-2304 2304 4x40G 32x10G or 8x40G 160 Gbps
UCS-IOM-2304-8FET Bundle that includes one
2304 plus 8 Fabric Extender
Transceivers (FETs)1
4x40G 32x10G or 8x40G 160 Gbps
UCS-IOM-2208XP 2208XP 8x40G 32x10G 80 Gbs
UCS-IOM2208-16FET Bundle that includes one
2208XP plus 16 Fabric
Extender Transceivers (FETs)1
8x40G 32x10G 80 Gbs
UCS-IOM-2204XP 2204XP 4x40G 16x10G 40 Gbs
UCS-IOM2204-8FET Bundle that includes one
2204XP plus 8 Fabric
Extender Transceivers (FETs)1
4x40G 16x10G 40 Gbs
Approved Configurations
(1) Choose one or two identical Fabric I/O Extenders, or
(2) Choose one or two identical Fabric Extender bundles (includes one Fabric Extender plus
transceivers)
Notes . . .
1. For more information on Fabric Extender bundles, see Fabric Extender Bundles on page 41.
Cisco UCS 5108 Blade Server Chassis
16
CONFIGURING the CHASSIS
Caveats
Do not use any Fabric Extender transceivers other than those that come in the bundles.
You cannot combine a 6324 Fabric Interconnect and a Fabric Extender in the same chassis
NOTE: The Cisco UCS 2304 Fabric Extender is not compatible with the Cisco UCS
6200 Fabric Interconnect series
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
17
STEP 3 SELECT FABRIC INTERCONNECTS
The Fabric Interconnect options are:
Cisco UCS 6324 Fabric Interconnect
Choose Fabric Interconnects
The available Fabric Interconnects are listed in Table 6. Each Fabric Interconnect integrates the
functions of a Fabric I/O Extender and Fabric Interconnect and connects directly to external
Nexus switches by means of several ports of 10GbE and Fibre Channel over Ethernet (FCoE).
Table 6 Available Fabric Interconnects
Product ID (PID) Fabric Interconnect
Number of
Internal
GbE/FCoE
Ports
Number of
FCoE Uplink
Ports
Number of
40GbE/FCoE
Scalability
Ports1
UCS-FI-M-6324 UCS 6324 in-chassis FI
with1 x 40G QSFP+
expansion port, and 16
10G-KR links to servers
16x10G 4x1G or 10G 140 Gbs
(one 40 GbE
Port)
Approved Configurations
(1) Choose one or two identical Fabric Interconnects
Caveats
You must select either one or two identical Fabric Interconnects.
You cannot combine a 6324 Fabric Interconnect and a Fabric Extender in the same chassis
1. The scalability port supports a QSFP+ breakout cable.
Total Chassis
I/O per Fabric
Interconnect
Cisco UCS 5108 Blade Server Chassis
18
CONFIGURING the CHASSIS
STEP 4 CHOOSE ADDITIONAL COMPONENTS (OPTIONAL)
The Cisco UCS FEX and FIOM support SFP+ Ethernet transceivers, SFP transceivers, SFP+ copper Twinax
cables with integrated transceivers, SFP Fibre Channel transceivers, QSFP transceivers, and QSFP cables.
The Cisco UCS 2204XP Fabric Extender (Figure 7) has four 10 Gigabit Ethernet, FCoE-capable, SFP+ ports
that connect the blade chassis to the fabric interconnect. Each Cisco UCS 2204XP has sixteen 10 Gigabit
Ethernet ports connected through the midplane to each half-width slot in the chassis. Typically configured
in pairs for redundancy, two fabric extenders provide up to 80 Gbps of I/O to the chassis. This product
support 10 Gigabit Ethernet SFP+ copper Twinax cables for short distances and SFP+ optics for longer
distances.
The Cisco UCS 2208XP Fabric Extender (Figure 7) has eight 10 Gigabit Ethernet, FCoE-capable, Enhanced
Small Form-Factor Pluggable (SFP+) ports that connect the blade chassis to the fabric interconnect. Each
Cisco UCS 2208XP has thirty-two 10 Gigabit Ethernet ports connected through the midplane to each
half-width slot in the chassis. Typically configured in pairs for redundancy, two fabric extenders provide up
to 160 Gbps of I/O to the chassis. This product support 10 Gigabit Ethernet SFP+ copper Twinax cables for
short distances and SFP+ optics for longer distances.
The Cisco UCS 2304 Fabric Extender (Figure 7) has four 40 Gigabit Ethernet, FCoE-capable, Quad Small
Form-Factor Pluggable (QSFP+) ports that connect the blade chassis to the fabric interconnect. Each Cisco
UCS 2304 can provide one 40 Gigabit Ethernet ports connected through the midplane to each half-width slot
in the chassis, giving it a total eight 40G interfaces to the compute. Typically configured in pairs for
redundancy, two fabric extenders provide up to 320 Gbps of I/O to the chassis. This product support 40
Gigabit Ethernet QSFP+ copper Twinax cables for short distances and QSFP+ optics for longer distances.
The Cisco UCS 6324 Fabric Interconnect supports a wide variety of 10 Gigabit Ethernet connectivity options
using Cisco 10GBASE SFP+ modules. In addition, the four SFP+ uplink ports support 1 Gigabit Ethernet
connectivity options using 1GBASE SFP modules. Alternatively, 2/4/8-Gbps Fibre Channel SFP+ interfaces
are supported.
The supported transceivers and cables are shown in Table 7. Additional transceiver and cable compatibility
details for Cisco UCS products is available at:
https://www.cisco.com/c/en/us/support/interfaces-modules/transceiver-modules/products-device-suppor
t-tables-list.html
Table 7 SFP+ Transceivers
Product ID Description FEX or FIOM
2204 2208 2304 6324
SFP+ Transceivers
SFP-10G-SR 10GBASE-SR SFP+ module (multimode fiber
[MMF]) X X X
SFP-10G-SR-X 10GBASE-SR SFP+ module (multimode fiber
[MMF]) - Extended Operating Temperature
Range X X X
SFP-10G-LR 10GBASE-LR SFP+ module (single-mode fiber
[SMF]) X X X
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
19
SFP+ Transceivers
SFP-10G-LR-X 10GBASE-LR SFP+ module (single-mode fiber
[SMF]) - Extended Operating Temperature
Range X X X
SFP-10G-SR-S 10GBASE-SR SFP+ module, (multi-mode fiber
[MMF]) — no FCoE support X X
SFP-10G-LR-S SFP-10G-LR-S 10GBASE-LR SFP +module
(single-mode fiber [SMF]) — no FCoE support X X
FET-10G FET-10G 10GBASE-FET SFP+ module
(multimode fiber [MMF]) X X
SFP 1-Gigabit Transceivers
GLC-T 1000BASE-T SFP transceiver module for
Category 5 copper wire X X
GLC-TE 1000BASE-T SFP transceiver module for
Category 5 copper wire X
GLC-LH-SM 1000BASE-LX/LH SFP transceiver module,
MMF/SMF, 1310-nm wavelength, dual LC/PC
connector X X
GLC-LH-SMD 1000BASE-LX/LH SFP transceiver module,
MMF/SMF, 1310nm, DOM X
GLC-SX-MM 1000BASE-SX SFP transceiver module, MMF,
850nm wavelength, dual LC/PC connector X X
GLC-SX-MMD 1000BASE-SX SFP transceiver module, MMF,
850nm, DOM X
QSFP Transceivers
QSFP-40G-SR4 40zGBASE-SR4 QSFP module (multimode fiber
[MMF] at 100m) X
QSFP-40G-SR4-S 40zGBASE-SR4 QSFP module (multimode fiber
[MMF] at 100m) X
QSFP-40G-CSR4 40GBASE Extended CSR4 QSFP module (MMF at
300m) X
QSFP-40G-LR4 Cisco 40GBASE-LR4 QSFP+ transceiver module
for SMF, duplex LC connector X
QSFP-40G-LR4-S Cisco 40GBASE-LR4 QSFP+ transceiver module
for SMF, duplex LC connector X
FET-40G Cisco 40G Line Extender for FEX X
Table 7 SFP+ Transceivers (continued)
Product ID Description FEX or FIOM
2204 2208 2304 6324
Cisco UCS 5108 Blade Server Chassis
20
CONFIGURING the CHASSIS
SFP+ Copper and Optical Cables with Integrated Transceivers
SFP-H10GB-CU1M SFP-H10GB-CU1M 10GBASE-CU SFP+ 1-meter
cable X X X
SFP-H10GB-CU3M SFP-H10GB-CU3M 10GBASE-CU SFP+ 3-meter
cable X X X
SFP-H10GB-CU5M SFP-H10GB-CU5M 10GBASE-CU SFP+ 5-meter
cable X X X
SFP-H10GB-ACU7M SFP-H10GB-ACU7M 10GBASE-CU SFP+ 7-meter
cable X X X
SFP-H10GB-ACU10M SFP-H10GB-ACU10M 10GBASE-CU SFP+
10-meter cable X X X
SFP-10G-AOC1M SFP-10G-AOC1M 10GBASE Active Optical SFP+
Cable, 1M X X X
SFP-10G-AOC3M SFP-10G-AOC3M 10GBASE Active Optical SFP+
Cable, 3M X X X
SFP-10G-AOC5M SFP-10G-AOC5M 10GBASE Active Optical SFP+
Cable, 5M X X X
SFP-10G-AOC7M SFP-10G-AOC5M 10GBASE Active Optical SFP+
Cable, 7M X X X
SFP-10G-AOC10M SFP-10G-AOC5M 10GBASE Active Optical SFP+
Cable, 10M X X X
QSFP Cables with Integrated Transceivers
QSFP-4x10G-AC7M Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ direct-attach breakout cable, 7-meter,
active X X
QSFP-4x10G-AC10M Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ direct-attach breakout cable, 10-meter,
active X X
QSFP-H40G-CU1M Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 1-meter, passive X
QSFP-H40G-CU3M Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 3-meter, passive X
QSFP-H40G-CU5M Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 5-meter, passive X
QSFP-H40G-ACU7M Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 7-meter, active X
Table 7 SFP+ Transceivers (continued)
Product ID Description FEX or FIOM
2204 2208 2304 6324
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
21
QSFP Cables with Integrated Transceivers
QSFP-H40G-ACU10M Cisco 40GBASE-CR4 QSFP+ direct-attach
copper cable, 10-meter, active X
QSFP-4SFP10G-CU1M Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ passive direct-attach copper transceiver
assembly, 1 meter X X
QSFP-4SFP10G-CU3M Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ passive direct-attach copper transceiver
assembly, 3 meter X X
QSFP-4SFP10G-CU5M Cisco 40GBASE-CR4 QSFP+ to 4 10GBASE-CU
SFP+ passive direct-attach copper transceiver
assembly, 5 meter X X
QSFP-4X10G-AOC1M Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 1-meter X X
QSFP-4X10G-AOC3M Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 3-meter X X
QSFP-4X10G-AOC5M Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 5-meter X X
QSFP-4X10G-AOC7M Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 7-meter X X
QSFP-4X10G-AOC10M Cisco 40GBASE-AOC QSFP to 4 SFP+ Active
Optical breakout Cable, 10-meter X X
Fibre Channel SFP Transceiver (Cisco UCS 6324 Fabric Interconnect)
DS-SFP-FC4G-SW 4 Gbps Fibre Channel-SW SFP, LC connector X
DS-SFP-FC4G-LW 4 Gbps Fibre Channel-LW SFP, LC, (10km
Reach) X
DS-SFP-FC8G-SW 8-Gbps Fibre Channel SW SFP+, LC connector X
DS-SFP-FC8G-LW 8 Gbps Fibre Channel LW SFP+, LC X
Table 7 SFP+ Transceivers (continued)
Product ID Description FEX or FIOM
2204 2208 2304 6324
Table 8 Cabling specifications
Connector (Media) Cable Type Distance Power Standard
SFP+ copper CU Twinax 1, 3, 5, 7 and 10 m 0.1W SFF 8431
SFP+ FET MM OM2
MM OM3
MM OM4
25 and 100 m 1.0W IEEE 802.3ae
SFP+ short-reach (SR) and
multimode fiber (MMF) MM OM2
MM OM3
MM OM4
82 and 300 m 1.0W IEEE 802.3ae
SFP+ long-reach (LR) MMF and
SR SMF Up to 300 m 1.0W IEEE 802.3ae
QSFP+ copper CU Twinax 1, 3, 5, 7 and 10 m 0.1W SFF 8635
QSFP+ FET MM OM2
MM OM3
MM OM4
30 and 100 m 1.5W IEEE 802.3ba
QSFP+ short-reach (SR) and
multimode fiber (MMF) MM OM2
MM OM3
MM OM4
30 and 300 m 1.5W IEEE 802.3ba
QSFP+ long-reach (LR) MMF and
SR SMF Up to 300 m 3.5W IEEE 802.3ba
Cisco UCS 5108 Blade Server Chassis
22
CONFIGURING the CHASSIS
Choose QSFP+ Port License
In order to use the QSFP+ port on 6324 FI, a license must be added. See Table 9.
Table 9 QSFP+ Port License
Product ID (PID) PID Description
UCS-6324-40G Mini FI License for 40G Scalability Port
Caveats
You should order enough SFPs, QSFPs and cables to accommodate your maximum
foreseeable needs.
If you selected a QSFP+ transceiver, make sure you choose a QSFP+ port license.
For the 6324, observe the following:
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
23
The maximum number of SFP+ transceivers, SFP optical transceivers, copper
transceivers, or Twinax cables must be less than or equal to four. A minimum of one
of these must be installed for the 6324 to have network connectivity.
The maximum number of Fibre Channel SFPs must be less than or equal to three.
The reason for this is that at least one SFP+ port on the 6324 must be free so the
6324 can connect to a network.
Cisco UCS 5108 Blade Server Chassis
24
CONFIGURING the CHASSIS
STEP 5 CHOOSE POWER SUPPLIES
The 5108 blade chassis accommodates up to four power supplies.
Choose Power Supplies
The available power supplies are listed in Table 10
Table 10 Available Power Supplies
Product ID (PID) PID Description
UCSB-PSU-2500ACDV 2500 W Platinum AC Hot Plug Power Supply - DV
UCSB-PSU-2500DC48 2500 W DC -48 V power supply
UCSB-PSU-2500HVDC 2500 W DC high voltage (200 to 380 VDC) DC power supply
.
Approved Configurations
(1) Choose from 2 to 4 power supplies
Caveats
You must select either an AC, DC, or HVDC version of the 5108 blade chassis, which is
configured with the appropriate input power module (AC, DC or HVDC).
Mixing AC, DC or HVDC PSUs within the same 5108 blade chassis is not supported.
The blade chassis input power module cannot be replaced in the field to convert the input
type e.g. converting a DC input to an AC input blade chassis.
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
25
STEP 6 SELECT INPUT POWER CORD(s)
Select the appropriate AC power cords listed in Table 11. You may select up to 4 power cords.
Table 11 Available Power Cords
Product ID (PID) PID Description Comment
CAB-AC-16A-AUS 16A, 250 VAC Australia
UCSB-CABL-C19-BRZ 16A, 250 VAC Brazil
CAB-AC16A-CH 16A, 250 VAC China
CAB-AC-2500W-EU 16A, 250 VAC Europe
CAB-AC-2500W-INT 16A, 250 VAC International
CAB-AC-2500W-ISRL 16A, 250 VAC Israel
CAB-US620P-C19-US 16A, 250VAC
NEMA L6-20P to IEC C19 USA
CAB-AC-C6K-TWLK 20A, 250VAC
NEMA L6-20 (Twist Lock) to IEC C19 USA
CAB-ACS-16 16A, 250 VAC Switzerland
CAB-C19-CBN 16A, 250 VAC Jumper cord C19/C20
CAB-US515P-C19-US 15A, 125 VAC
NEMA 5-15 to IEC-C19 USA
CAB-US520-C19-US 20A, 125 VAC
NEMA 5-20 to IEC-C19 USA
CAB-BS1363-C19-UK 13A, 250 VAC
BS1363 to IEC C19 UK
CAB-9K16A-KOR 16A, 250 VAC
CEE 7/7 to IEC C19 South Korea
CAB-C19-C20-3M-JP 16A, 250 VAC Japan
CAB-IR2073-C19-AR 20A, 250 VAC
IRSM 2073 to IEC C19 Argentina
CAB-SABS-C19-IND 16A, 250 VAC
SABS 164-1 to IEC C19 India
CAB-S132-C19-ISRL 16A, 250 VAC
S132 to IEC C19 Isreal
CAB-C2316-C19-IT 16A, 250 VAC
CEI 23-16 to IEC C19 Italy
Cisco UCS 5108 Blade Server Chassis
26
CONFIGURING the CHASSIS
STEP 7 CHOOSE SERVICE and SUPPORT LEVEL
A variety of service options are available, as described in this section.
Unified Computing Warranty, No Contract
If you have noncritical implementations and choose to have no service contract, the following coverage is
supplied:
Three-year parts coverage.
Next business day (NBD) onsite parts replacement eight hours a day, five days a week.
90-day software warranty on media.
Ongoing downloads of BIOS, drivers, and firmware updates.
UCSM updates for systems with Unified Computing System Manager. These updates include
minor enhancements and bug fixes that are designed to maintain the compliance of UCSM
with published specifications, release notes, and industry standards.
Smart Net Total Care (SNTC) for UCS
For support of the entire Unified Computing System, Cisco offers the Cisco SMARTnet for UCS Service. This
service provides expert software and hardware support to help sustain performance and high availability of
the unified computing environment. Access to Cisco Technical Assistance Center (TAC) is provided around
the clock, from anywhere in the world.
For the 5108 chassis, there is Smart Call Home, which provides proactive, embedded diagnostics and
real-time alerts. For systems that include Unified Computing System Manager, the support service includes
downloads of UCSM upgrades. The Cisco SMARTnet for UCS Service includes flexible hardware replacement
options, including replacement in as little as two hours. There is also access to Cisco's extensive online
technical resources to help maintain optimal efficiency and uptime of the unified computing environment.
You can choose a desired service listed in Table 12.
Table 12 Cisco SNTC for UCS Service (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-PREM-6508AC2 C2P Yes SNTC 24X7X2OS
CON-UCSD8-6508AC2 UCSD8 Yes UC SUPP DR 24X7X2OS*
CON-C2PL-6508AC2 C2PL Yes LL 24X7X2OS**
CON-OSP-6508AC2 C4P Yes SNTC 24X7X4OS
CON-UCSD7-6508AC2 UCSD7 Yes UCS DR 24X7X4OS*
CON-C4PL-6508AC2 C4PL Yes LL 24X7X4OS**
CON-USD7L-6508AC2 USD7L Yes LLUCS HW DR
CON-OSE-6508AC2 C4S Yes SNTC 8X5X4OS
CON-UCSD6-6508AC2 UCSD6 Yes UC SUPP DR 8X5X4OS*
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
27
Smart Net Total Care for Cisco UCS Onsite Troubleshooting Service
An enhanced offer over traditional Smart Net Total Care which provides onsite troubleshooting expertise to
aid in the diagnostics and isolation of hardware issue within our customers’ Cisco Unified Computing System
(UCS) environment. It is delivered by a Cisco Certified field engineer (FE) in collaboration with remote TAC
engineer and Virtual Internet working Support Engineer (VISE). You can choose a desired service listed in
Table 13.
CON-SNCO-6508AC2 SNCO Yes SNTC 8x7xNCDOS****
CON-OS-6508AC2 CS Yes SNTC 8X5XNBDOS
CON-UCSD5-6508AC2 UCSD5 Yes UCS DR 8X5XNBDOS*
CON-S2P-6508AC2 S2P No SNTC 24X7X2
CON-S2PL-6508AC2 S2PL No LL 24X7X2**
CON-SNTP-6508AC2 SNTP No SNTC 24X7X4
CON-SNTPL-6508AC2 SNTPL No LL 24X7X4**
CON-SNTE-6508AC2 SNTE No SNTC 8X5X4
CON-SNC-6508AC2 SNC No SNTC 8x7xNCD****
CON-SNT-6508AC2 SNT No SNTC 8X5XNBD
CON-SW-6508AC2 SW No SNTC NO RMA
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-PREM-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-PREM-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix (Example:
*Includes Drive Retention (see below for full description)
**Includes Local Language Support (see below for full description) Only available in China and Japan
***Includes Local Language Support and Drive Retention Only available in China and Japan
****Available in China Only
Table 13 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-OSPT-6508AC2 OSPT Yes 24X7X4OS Trblshtg
CON-OSPTD-6508AC2 OSPTD Yes 24X7X4OS TrblshtgDR*
Table 12 Cisco SNTC for UCS Service (PID UCSB-5108-AC2)
Cisco UCS 5108 Blade Server Chassis
28
CONFIGURING the CHASSIS
Solution Support for UCS
Solution Support includes both Cisco product support and solution-level support, resolving complex issues in
multivendor environments, on average, 43% more quickly than product support alone. Solution Support is a
critical element in data center administration, to help rapidly resolve any issue encountered, while
maintaining performance, reliability, and return on investment.
This service centralizes support across your multivendor Cisco environment for both our products and
solution partner products you’ve deployed in your ecosystem. Whether there is an issue with a Cisco or
solution partner product, just call us. Our experts are the primary point of contact and own the case from
first call to resolution. For more information please refer to the following url:
http://www.cisco.com/c/en/us/services/technical/solution-support.html?stickynav=1
You can choose a desired service
listed in Table 14.
CON-OSPTL-6508AC2 OSPTL Yes 24X7X4OS TrblshtgLL**
CON-OPTLD-6508AC2 OPTLD Yes 24X7X4OS TrblshtgLLD***
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-OSPT-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-OSPT-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix (Example:
*Includes Drive Retention (see below for full description)
**Includes Local Language Support (see below for full description) Only available in China and Japan
***Includes Local Language Support and Drive Retention Only available in China and Japan
Table 14 Solution Support for UCS Service (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-SSC2P-6508AC2 SSC2P Yes SOLN SUPP 24X7X2OS
CON-SSC4P-6508AC2 SSC4P Yes SOLN SUPP 24X7X4OS
CON-SSC4S-6508AC2 SSC4S Yes SOLN SUPP 8X5X4OS
CON-SSCS-6508AC2 SSCS Yes SOLN SUPP 8X5XNBDOS
CON-SSDR7-6508AC2 SSDR7 Yes SSPT DR 24X7X4OS*
CON-SSDR5-6508AC2 SSDR5 Yes SSPT DR 8X5XNBDOS*
CON-SSS2P-6508AC2 SSS2P No SOLN SUPP 24X7X2
CON-SSSNP-6508AC2 SSSNP No SOLN SUPP 24X7X4
Table 13 SNTC for Cisco UCS Onsite Troubleshooting Service (PID UCSB-5108-AC2)
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
29
Smart Net Total Care for UCS Hardware Only Service
For faster parts replacement than is provided with the standard Cisco Unified Computing System
warranty,
Cisco offers the Cisco Smart Net Total Care for UCS Hardware Only Service. You can choose from
two levels of
advanced onsite parts replacement coverage in as little as four hours. Smart Net Total Care
for UCS
Hardware Only Service provides remote access any time to Cisco support professionals
who can determine if
a return materials authorization (RMA) is required. You can choose a desired service listed in Table 15.
CON-SSSNE-6508AC2 SSSNE No SOLN SUPP 8X5X4
CON-SSSNC-6508AC2 SSSNC No SOLN SUPP NCD**
CON-SSSNT-6508AC2 SSSNT No SOLN SUPP 8X5XNBD
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON- SSC2P-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-SSC2P-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)
**Available in China only
Table 15 SNTC for UCS Hardware Only Service (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-UCW7-6508AC2 UCW7 Yes UCS HW 24X7X4OS
CON-UCWD7-6508AC2 UCWD7 Yes UCS HW+DR 24X7X4OS*
CON-UCW7L-6508AC2 UCW7L Yes LL UCS 24X7X4OS**
CON-UWD7L-6508AC2 UWD7L Yes LL UCS DR 24X7X4OS***
CON-UCW5-6508AC2 UCW5 Yes UCS HW 8X5XNBDOS
CON-UCWD5-6508AC2 UCWD5 Yes UCS HW+DR 8X5XNBDOS*
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-UCW7-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-UCW7-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)
Table 14 Solution Support for UCS Service (PID UCSB-5108-AC2)
Cisco UCS 5108 Blade Server Chassis
30
CONFIGURING the CHASSIS
Partner Support Service for UCS
Cisco Partner Support Service (PSS) is a Cisco Collaborative Services service offering that is
designed for
partners to deliver their own branded support and managed services to enterprise
customers. Cisco PSS
provides partners with access to Cisco's support infrastructure and assets
to help them:
Expand their service portfolios to support the most complex network environments
Lower delivery costs
Deliver services that increase customer loyalty
PSS options enable eligible Cisco partners to develop and
consistently deliver high-value technical support
that capitalizes on Cisco intellectual assets.
This helps partners to realize higher margins and expand their
practice.
PSS is available to all Cisco PSS partners.
The two Partner Unified Computing Support Options include:
Partner Support Service for UCS
Partner Support Service for UCS Hardware Only
PSS for UCS provides hardware and software support, including triage
support for third party software,
backed by Cisco technical resources and level three support. You can choose a desired service listed in
Table 16.
**Includes Local Language Support (see below for full description) Only available in China and Japan
***Includes Local Language Support and Drive Retention Only available in China and Japan
Table 16 PSS for UCS (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-PSJ8-6508AC2 PSJ8 Yes UCS PSS 24X7X2 OS
CON-PSJ7-6508AC2 PSJ7 Yes UCS PSS 24X7X4 OS
CON-PSJD7-6508AC2 PSJD7 Yes UCS PSS 24X7X4 DR*
CON-PSJ6-6508AC2 PSJ6 Yes UCS PSS 8X5X4 OS
CON-PSJD6-6508AC2 PSJD6 Yes UCS PSS 8X5X4 DR*
CON-PSJ4-6508AC2 PSJ4 No UCS SUPP PSS 24X7X2
CON-PSJ3-6508AC2 PSJ3 No UCS SUPP PSS 24X7X4
CON-PSJ2-6508AC2 PSJ2 No UCS SUPP PSS 8X5X4
Table 15 SNTC for UCS Hardware Only Service (PID UCSB-5108-AC2)
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
31
PSS for UCS Hardware Only
PSS for UCS Hardware Only provides customers with replacement parts in as
little as two hours and provides
remote access any time to Partner Support professionals who can determine if a return materials authorization
(RMA) is required. You can choose a desired service listed in Table 17.
Table 17 PSS for UCS Hardware Only (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-PSW7-6508AC2 PSW7 Yes UCS W PSS 24X7X4 OS
CON-PSWD7-6508AC2 PSWD7 Yes UCS W PSS 24X7X4 DR*
CON-PSW6-6508AC2 PSW6 Yes UCS W PSS 8X5X4 OS
CON-PSWD6-6508AC2 PSWD6 Yes UCS W PSS 8X5X4 DR*
CON-PSW4-6508AC2 PSW4 No UCS W PL PSS 24X7X2
CON-PSW3-6508AC2 PSW3 No UCS W PL PSS 24X7X4
CON-PSW2-6508AC2 PSW2 No UCS W PL PSS 8X5X4
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-PSW7-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-PSW7-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)
CON-PSJ1-6508AC2 PSJ1 No UCS SUPP PSS 8X5XNBD
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-PSJ7-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-PSJ7-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix
*Includes Drive Retention (see below for description)
Table 16 PSS for UCS (PID UCSB-5108-AC2)
Cisco UCS 5108 Blade Server Chassis
32
CONFIGURING the CHASSIS
Unified Computing Combined Support Service
Combined Services makes it easier to purchase and manage required services under one
contract. SNTC
services for UCS help increase the availability of your vital data center
infrastructure and realize the most
value from your unified computing investment. The more
benefits you realize from the Cisco Unified
Computing System (Cisco UCS), the more important
the technology becomes to your business. These services
allow you to:
Optimize the uptime, performance, and efficiency of your UCS
Protect your vital business applications by rapidly identifying and addressing issues
Strengthen in-house expertise through knowledge transfer and mentoring
Improve operational efficiency by allowing UCS experts to augment your internal staff
resources
Enhance business agility by diagnosing potential issues before they affect your operations
You can choose a desired service listed in Table 18.
Table 18 Combined Support Service for UCS (PID UCSB-5108-AC2)
Service SKU Service Level GSP On Site? Description
CON-NCF2P-6508AC2 NCF2P Yes CMB SVC 24X7X2OS
CON-NCF4P-6508AC2 NCF4P Yes CMB SVC 24X7X4OS
CON-NCF4S-6508AC2 NCF4S Yes CMB SVC 8X5X4OS
CON-NCFCS-6508AC2 NCFCS Yes CMB SVC 8X5XNBDOS
CON-NCF2-6508AC2 NCF2 No CMB SVC 24X7X2
CON-NCFP-6508AC2 NCFP No CMB SVC 24X7X4
CON-NCFE-6508AC2 NCFE No CMB SVC 8X5X4
CON-NCFT-6508AC2 NCFT No CMB SVC 8X5XNBD
CON-NCFW-6508AC2 NCFW No CMB SVC SW
Note: For PID UCSB-5108-AC2-UPG, select Service SKU with 6508AC2U suffix (Example:
For PID UCSB-5108-DC2, select Service SKU with 6508DC2 suffix (Example: CON-NCF2P-6508DC2)
For PID UCSB-5108-DC2-UPG, select Service SKU with 6508DC2U suffix (Example:
For PID UCSB-5108-HVDC, select Service SKU with 6508HVD suffix (Example: CON-NCF2P-6508HVD)
For PID UCSB-5108-HVDC-UPG, select Service SKU with 6508HVDU suffix (Example:CON-NCF2P-6508HVDU)
UCS Drive Retention Service
With the Cisco Unified Computing Drive Retention Service, you can obtain a new disk drive in exchange for
a faulty drive without returning the faulty drive.
Cisco UCS 5108 Blade Server Chassis
CONFIGURING the CHASSIS
33
Sophisticated data recovery techniques have made classified, proprietary, and confidential information
vulnerable, even on malfunctioning disk drives. The Drive Retention service enables you to retain your
drives and ensures that the sensitive data on those drives is not compromised, which reduces the risk of any
potential liabilities. This service also enables you to comply with regulatory, local, and federal
requirements.
If your company has a need to control confidential, classified, sensitive, or proprietary data, you might
want to consider one of the Drive Retention Services listed in the above tables (where available)
NOTE: Cisco does not offer a certified drive destruction service as part of this
service.
Local Language Technical Support for UCS
Where available, and subject to an additional fee, local language support for calls on all assigned severity
levels may be available for specific product(s) - see tables above.
For a complete listing of available services for Cisco Unified Computing System, see the following URL:
http://www.cisco.com/en/US/products/ps10312/serv_group_home.html
Cisco UCS 5108 Blade Server Chassis
34
SUPPLEMENTAL MATERIAL
SUPPLEMENTAL MATERIAL
System Overview
The Cisco Unified Computing System™ (Cisco UCS™) is a next-generation data center platform that unites
compute, network, storage access, and virtualization resources into a cohesive system designed to reduce
total cost of ownership (TCO) and increase business agility. The system integrates a low-latency, lossless
unified fabric with enterprise-class, x86-architecture servers. The system is an integrated, scalable,
multichassis platform in which all resources participate in a unified management domain.
Cisco UCS and Blade Server Access
In a multilayer data center design, you can replace core Cisco Nexus 7000 Series Switches with the Cisco
Nexus 9500 platform, or replace the core with the Cisco Nexus 9500 platform and the access layer with the
Cisco Nexus 9300 platform. You can also connect an existing Cisco Unified Computing System™ (Cisco UCS®)
and blade server access layer to Insieme hardware (Figures 9 and 10).
Figure 9 Classic Design Using Cisco Nexus 7000 and 5000 Series and Fabric Extenders
Cisco UCS 5108 Blade Server Chassis
SUPPLEMENTAL MATERIAL
35
Figure 10 Classic Design Using Cisco Nexus 7000 and 5000 Series and Fabric Extenders
Cisco UCS Fabric Extenders bring the unified fabric into the blade server enclosure, providing multiple 10 or
40 Gigabit Ethernet connections between blade servers and the fabric interconnect, simplifying diagnostics,
cabling, and management.
The Fabric Extenders extend the I/O fabric between the Cisco UCS 6200 or 6300 Series Fabric Interconnects
and the Cisco UCS 5108 Blade Server Chassis, enabling a lossless and deterministic Fibre Channel over
Ethernet (FCoE) fabric to connect all blades and chassis together. Since the fabric extender is similar to a
distributed line card, it does not perform any switching and is managed as an extension of the fabric
interconnects. This approach removes switching from the chassis, reducing overall infrastructure
complexity and enabling Cisco UCS to scale to many chassis without multiplying the number of switches
needed, reducing TCO and allowing all chassis to be managed as a single, highly available management
domain.
The Fabric Extenders also manage the chassis environment (the power supply and fans as well as the
blades) in conjunction with the fabric interconnect. Therefore, separate chassis management modules are
not required.
The Fabric Extenders fit into the back of the Cisco blade chassis. Each blade chassis can support up to two
fabric extenders, allowing increased capacity and redundancy.
Cisco UCS 5108 Blade Server Chassis
36
SUPPLEMENTAL MATERIAL
Connectivity between each unique blade and the Fabric Extenders varies according to the type of blade, its
available adapter card slots, and the type of card plugged into each slot. See the individual blade server
spec sheets for detailed connectivity information and connectivity diagrams at this link:
http://www.cisco.com/en/US/products/ps10280/products_data_sheets_list.html
Cisco UCS 5108 Blade Server Chassis
SUPPLEMENTAL MATERIAL
37
Connectivity
This section explains the connectivity between the Fabric Interconnects (FIs) and Fabric Extenders (FEX).
The Fabric Extenders are extensions of the Fabric Interconnects and act as remote line cards to form a
distributed modular fabric system. The fabric extension is accomplished through the FEX fabric link, which
is the connection between the Fabric Interconnect and the FEX.
A minimum of one connection between the FI and FEX is required to provide server connectivity. Depending
on the FEX model, subsequent connections can be up to eight links, which provides added bandwidth to the
servers.
5108 Blade Chassis Server Connectivity
For the 5100 blade chassis series, the Fabric Extender modules (up to two) plug into the back of the UCS
5108 series blade server chassis. A midplane connects the blade servers to the Fabric Extenders. The 5108
chassis accommodates the following FEXs:
Cisco UCS 2304
Cisco UCS 2208XP
Cisco UCS 2204XP
Figure 11 shows how the FEX modules in the blade chassis connect to the FIs.
Figure 11 Connecting Bl
192749
Fabric Interconnect A (6332-16UP)
Fabric Interconnect B (6332-16UP)
ade Chassis Fabric Extenders to Fabric Interconnect Chassis
NOTE: The Cisco UCS 2304 Fabric Extender is not compatible with the Cisco UCS
6200 Fabric Interconnect series
Cisco UCS 5108 Blade Server Chassis
38
SUPPLEMENTAL MATERIAL
Blade Chassis Connection Types
In a blade chassis, the FEX fabric link (the link between the FEX and the FI) supports two different types of
connections:
Discrete Mode
Port Channel Mode
In discrete mode, a half-width server slot is pinned to a given FEX fabric link. The supported number of links
are 1, 2, 4, and 8, as shown in Figure 12. The figure shows how each FEX fabric link services a particular
slot. It is an example of four FEX fabric link connections.
Figure 12 Discrete Mode FEX Fabric Link
Slot 1 Link 1
Link 4
Link 3
Link 2
Blade Half-Width Slot Numbers
Slot 2
Slot 3
Slot 4
Slot 8
Slot 7
Slot 6
Slot 5 Fabric InterconnectFabric Extender (FEX)
Blade Chassis
Table 19 shows the mapping from the blade chassis server half slots to the FEX fabric links.
Table 19 Blade Chassis Slot to Link Mapping
FEX Type Number of FEX Fabric Links Half-Width Server Slot to Link
Cisco UCS 2304,
Cisco UCS 2208XP, and
Cisco UCS 2204XP
1Server Slots 1 - 8 merged to link 1
2Server Slots 1, 3, 5, 7 merged to link 1
Server Slots 2, 4, 6, 8 merged to link 2
4Server Slots 1, 5 merged to link 1
Server Slots 2, 6 merged to link 2
Server Slots 3, 7 merged to link 3
Server Slots 4, 8 merged to link 4
Cisco UCS 2208XP only 81:1 mapping. Each half-width server slot is pinned
to a single FEX fabric link.
Cisco UCS 5108 Blade Server Chassis
SUPPLEMENTAL MATERIAL
39
In port channel mode, the FEX fabric links are bundled into a single logical link (see Figure 13) to provide
higher bandwidth to the servers. Depending the FEX, up to 8 links can be port-channeled.
Figure 13 FEX Fabric Links in Port Channel Mode
Slot 1
Blade Half-Width Slot Numbers
Slot 2
Slot 3
Slot 4
Slot 8
Slot 7
Slot 6
Slot 5 Fabric InterconnectFabric Extender (FEX)
Blade Chassis
https://www.cisco.com/c/en/us/products/collateral/servers-unified-computing/ucs-6300-series-fabric-int
erconnects/datasheet-c78-736682.html
Cisco UCS 5108 Blade Server Chassis
40
SUPPLEMENTAL MATERIAL
Connectivity Cisco 6324 Fabric Interconnects
Figure 14 is a system diagram showing a Cisco UCS 5108 chassis with internal Cisco UCS 6324 Fabric
Interconnects connected in a system.
The Cisco 6324 Fabric Interconnect provides the management and communication backbone for Cisco UCS
Mini. The chassis, blades, and rack-mount servers that are attached to interconnects are part of a single
highly available management domain
Because it supports Cisco Unified Fabric, the 6324 Fabric Interconnect offers customers flexibility to
support LAN and storage connectivity for all servers within its domain at configuration. Typically deployed
in redundant pairs, the 6324 Fabric Interconnect delivers uniform access to both networks and storage to
facilitate a fully virtualized environment. For additional details see UCS mini at
https://www.cisco.com/c/en/us/products/servers-unified-computing/index.html#~stickynav=2
Figure 14 System Diagram (Cisco UCS 5108 Chassis with Internal Cisco UCS 6324 Fabric Interconnects)
Cisco UCS 5108 Blade Chassis with 8 servers
and 2 Cisco UCS 6324 Fabric Interconnects
Upstream
Cisco UCS 5108 Blade Chassis with 8 servers
and 2 Cisco UCS 2204 Fabric Interconnects
Cisco UCS C220 M5 Rack Server
Cisco UCS C220 M5 Rack Server
Cisco UCS C220 M5 Rack Server
Cisco UCS C240 M5 Rack Server
Upstream
SFP 10-Gbps Cable
SFP 10-Gbps Cable
QSFP to 10-Gbps SFP Breakout Cable
Cisco UCS 5108 Blade Server Chassis
SUPPLEMENTAL MATERIAL
41
Fabric Extender Bundles
You can order three kinds of Fabric Extender bundles:
UCS-IOM2208-16FET
UCS-IOM2204-8FET
UCS-IOM-2304-8FET
NOTE: Cables connecting the Fabric Extender to the Fabric Interconnect using your
own multimode fiber (MMF) optical cables must have the same SFP (FET-10G= or
FET-40G=) on each end. Both the Fabric Extender ports and the corresponding Fabric
Interconnect ports should implement the same SFP or QSFP; otherwise, the servers
in the blade chassis might not be discovered.
The bundle includes a pair of Fabric Extender Transceivers (FETS) per FEX port.
The FETs are in an SFP+ and QSFP+ form-factor and support 10 Gbps or 40 Gbps full-duplex transmissions
between the Fabric Extender and Fabric Interconnect, using your own multimode fiber (MMF) optical
cables. The reach is 25 meters using MMF OM2 optical cables and 100 meters using MMF OM3 or OM4 optical
cables.
If you do not order the bundle that includes the transceivers, you can order the transceivers separately as
spares (PIDs: = FET-10G= or FET-40G=).
Cisco UCS 5108 Blade Server Chassis
42
TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS
Physical Dimensions and Specifications
Table 20 Cisco UCS 5108 Chassis Specifications
Parameter Value
Height 10.5 in. (26.7 cm); 6 rack unit (6RU)
Width 17.5 in. (44.5 cm); fits standard 19-inch square-hole rack (or round
hole threaded or non-threaded, with optional adapter kit)
Depth 32 in. (81.2 cm)
Weight 90 lbs (40.83 kg) empty, 255 lbs (115.66 kg) fully configured
Blade server slots 8 half-width slots, 4 full-width slots, or combination of half- and
full-width slots.
IO slots (for FIs or FEXs) 2
Fabric Extenders Compatible with 2208XP, 2204XP, and 2304XP Fabric Extenders
Fabric Interconnects Compatible with 6324 Fabric Interconnects
Power Four PSUs supporting N, N+1 and N+N redundancy.
Fans 8 hot-swappable fan modules supporting N+1 redundancy
Management Managed from the Cisco UCS 6200 or 6300 Series Fabric
Interconnects by Cisco UCS Manager (redundant management when
configured with two fabric extenders or two 6324 Fabric
Interconnects)
Backplane 1.2 TB of aggregate throughput; supports 10G-KR or 40G-KR
connections for 8 half-width blades.
Regulatory compliance Products comply with CE Markings per directives 2004/108/EC and
2006/108/EC1
Safety UCANL 60950-1
CAN/CSA-C22.2 No. 60950-1
EMC: Emissions 47CFR Part 15 (CFR 47) Class A
AS/NZS CISPR22 Class A
CISPR2 2 Class A
EN55022 Class A
ICES003 Class A
VCCI Class A
EN61000-3-2
EN61000-3-3
KN22 Class A
Cisco UCS 5108 Blade Server Chassis
TECHNICAL SPECIFICATIONS
43
EMC: Immunity EN50082-1
EN61000-6-1
EN55024
CISPR24
EN300386
KN 61000-4 Series
Table 20 Cisco UCS 5108 Chassis Specifications (continued)
Parameter Value
Cisco UCS 5108 Blade Server Chassis
44
TECHNICAL SPECIFICATIONS
Power Specifications
The specifications for the various 5108 power supplies are listed in Table 21.
Table 21 Power Supply
Variable UCSB-PSU-2500ACDV UCSB-PSU-2500DC48 UCSB-PSU-2500HVDC
Input Connector IEC320 C20 Panduit LCD4-14AF-L1Saf-D-Grid
Input Voltage Range (V
rms) 100 to 120 and 200 to 2402-48 to -60
Maximum Allowable
Input Voltage Range (V
rms)
90 to 132 and 180 to 2642-40 to -72
Frequency Range (Hz) 50 to 60 DC
Maximum Allowable
Frequency Range (Hz) 47 to 63 DC
Maximum Rated Output
(W) 1300/250032500
Nominal Input Voltage
(V rms) 100 120 208 230 -48
Nominal Input Current
(A rms) 14.9 12.4 13.8 12.3 59.2
Maximum Input at
Nominal Input Voltage
(W)
1444 1444 2778 2747 2840
Maximum Input at
Nominal Input Voltage
(VA)
1489 1489 2863 2832 2840
Minimum Rated
Efficiency (%)490 90 90 91 88
Minimum Rated Power
Factor40.97 0.97 0.97 0.97 NA
Maximum Inrush Current
(A peak) 35 90
Maximum Inrush Current
(ms) 0.2 0.2
Minimum Ride-Through
Time (ms)512 4
Notes . . .
1.Barrel-type terminal with 90-degree angle, two-hole tongue, which accommodates 1/0 AWG size copper
wire. The connector tongue width is 0.81-in, the stud hole spacing is 0.63-in and hole size is 0.25-in
200 to 380
180 to 400
DC
DC
2500
380
7.3
2778
2778
90
NA
35
0.2
12
Cisco UCS 5108 Blade Server Chassis
TECHNICAL SPECIFICATIONS
45
For configuration-specific power specifications, use the Cisco UCS Power Calculator at:
https://ucspowercalc.cisco.com
2.Low line operation (100-120VAC input) only supported with 6324 Fabric Interconnect
3.Maximum rated output is limited to 1300W when operating at low-line input voltage (100-120VAC)
4.This is the minimum rating required to achieve 80 PLUS Platinum certification, see test reports published
at http://www.80plus.org/for certified values and test reports
5.Time output voltage remains within regulation limits at 100% load, during input voltage dropout
Cisco UCS 5108 Blade Server Chassis
46
TECHNICAL SPECIFICATIONS
Environmental Specifications
The environmental specifications for the Cisco UCS 5108 blade chassis are listed in Table 22.
Table 22 UCS 5108 Blade Server Environmental Specifications
Parameter Minimum
Operating Temperature 10°C to 35°C (50°F to 95°F) with no direct sunlight
Maximum allowable operating temperature de-rated
1°C/300 m (1°F/547 ft) above 950 m (3117 ft)
Non-operating
Tem pera tur e -40°C to 65°C (-40°F to 149°F)
Maximum rate of change (operating and non-operating) 20°C/hr
Operating Relative
Humidity 8% to 90% and 24°C (75°F) maximum dew-point temperature,
non-condensing environment
Non-Operating Relative
Humidity 5% to 93% and 33°C (91°F) maximum dew-point temperature,
non-condensing environment
Operating Altitude 0 m to 3050 m (10,000 ft)
Non-Operating Altitude 0 m to 12,000 m (39,370 ft)
Non-Operating Vibration 2.2 Grms, 10 minutes per axis on each of the three axes
Operating Shock Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the
three axes
Non-Operating Shock Trapezoidal, 25 G, two drops on each of six faces: 175 inches per second
each corner on bottom face drop, 90 inches per second each corner on
other five faces
Safety UL60 950-1 No. 21CFR1040, CAN/CSA-C22.2 No. 60950-1, IRAM IEC60950-1,
CB IEC60950-1, EN
60950-1, IEC 60950-1, GOST IEC60950-1, SABS/CB IEC6095-1, CCC*/CB
GB4943-1995, CNS14336, CB IEC60950-1, AS/NZS 60950-1, GB4943
Immunity Verified to comply with EN55024, CISPR 24, KN 61000-4 Series, KN 24
Electrostatic Discharge Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV
contact discharge without physical damage
Acoustic Sound power: 68.8 dBA at ambient temperature 23° C measured using
the Dome Method
GOST MsanPiN 001-96Tested to ESD levels up to 15 kilovol