CONTROL EQUIPMENT AC/300 Call Adapter Call adaptor. Has one contact switch which is activated by the call. It can be used as an adaptor relay for installation of, e.g., acoustic signals or extra sound signals.The appliance can be installed in a single embedding box (90 x 90 x 40 mm). Supply voltage: from X2 line. Current demand: 20mA max. Max. load to relay contact: 1A, 24V (500mA if load is inductive). Item Details Width Height Depth Weight Module DIN 60mm 44mm 16mm 0.05kg 1 Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 0ºC +35ºC DIN guide 1 Yes, certified ICB/300LR Block Selector The unit, inserted in each block, enables the installation’s common devices (e.g. main entry panels, porter switchboards, actuators) to be shared by means of one or more common lines (max. 4, one ICB/300 selector for each line). Item Details Width Height Depth Weight Module DIN 145mm 105mm 64.5mm 0.41kg 6 Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 0ºC +35ºC DIN guide 1 Yes, certified IOD/303LR Coded Call Actuator Relay Remote actuator.The unit is connected to the data bus so that commands can be received from receivers, such as auxiliary and door lock release commands, and for controlling relays associated with them. Item Details Width Height Depth Weight Module DIN 145mm 70mm 64.5mm 0.29kg 4 Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 0ºC +35C DIN guide I Yes, certified Certification CE Yes, certified IPC/300LR Interface Item Details Weight Minimum package quantity 0.64kg I CONTROL EQUIPMENT IT/300 230V 50/60Hz Telephone Interface Telephone interface. Direct access to local line, even during a power cut. Different entry panel/telephone call ringing tones.Telephone line protected. Programming via telephone. Supply voltage: 230V AC. Item Details Width Height Depth Weight Module DIN Voltage 145mm 140mm 64.5mm 0.83kg 8 230V Frequency Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 50/60Hz 0ºC +35ºC DIN guide I Yes, certified RC/300 Call Repeater Call Repeater for system 300, X2 and X1.The unit can be used when a call signal must be heard in a room other than that the receiver is installed in.The repeaters reproduced an amplified version of the same call note produced by the receiver. Power supplied from X2 bus. Item Details Width Height Depth Weight 95mm 95mm 41mm 0.22kg Minimum working temperature Maximum working temperature Minimum package quantity Certification CE 0ºC +35ºC I Yes, certified Maximum working temperature Mounting type Minimum package quantity Certification CE +35ºC DIN guide I Yes, certified RIR/300LR Echelon Interface Repeater Item Details Width Height Depth Weight Minimum working temperature 60mm 44mm 14mm 0.05kg 0ºC VAS/100.20 Power Supplier 230V Additional power supplier. Supply voltage: 230V. Rated power: 60VA. Output voltage: 17.5V DC, 1.7A. Item Details Width Height Depth Weight Module DIN 210mm 145mm 64.5mm 1.57kg 12 Voltage Frequency Mounting type Minimum package quantity Certification CE 230V 50/60Hz DIN guide I Yes, certified CONTROL EQUIPMENT VLS/300 Remote Actuator Item Details Width Height Depth Weight Module DIN 70mm 145mm 64.5mm 0.22kg 4 Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 0ºC +35ºC DIN guide I Yes, certified VSE/300 Selector for Intercom Units This selector allows the installation of groups of intercom receivers in installation with standard receivers (system 300). Item Details Depth Height Width Minimum working temperature 16mm 44mm 60mm 0ºC Maximum working temperature Mounting type Minimum package quantity Certification CE +35ºC DIN guide I Yes, certified XA/300LR 230V 50/60Hz Power Supplier and Control Unit Power supply and control unit operating on ECHELON bus, enables system 300 coded installations and block-type installations to be created. Item Details Width Height Depth Weight Module DIN Voltage Current Request 210mm 145mm 64.5mm 0.95kg 12 230V R.3.0 Frequency Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 50/60Hz 0ºC +35ºC DIN guide I Yes, certified CONTROL EQUIPMENT XAS/300 230V 50/60Hz Power Supplier and Control Unit Control unit, 230V, that regenerate the X2 signals. Can be used in systems 300 and X2. Item Details Width Height Depth Weight Module DIN Voltage 210mm 145mm 64.5mm 1.30kg 12 230V BPT Security Systems (UK) Ltd, Unit 16, Sovereign Park, Cleveland Way, Hemel Hempstead, Hertfordshire, HP2 7DA Telephone: 01442 230800 Fax: 01442 244729 Email: sales@bpt.co.uk Website: www.bpt.co.uk Frequency Minimum working temperature Maximum working temperature Mounting type Minimum package quantity Certification CE 50/60Hz 0ºC +35C DIN guide I Yes, certified
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Create Date : 2006:02:23 12:32:44Z Creator : Adobe Acrobat 7.0 Modify Date : 2009:11:17 14:05:50Z Producer : Acrobat Distiller 7.0 for Macintosh Mod Date : 2009:11:17 14:05:50Z Creation Date : 2006:02:23 12:32:44Z Metadata Date : 2009:11:17 14:05:50Z Document ID : uuid:7307a09a-a468-11da-8f4c-0011247c532c Instance ID : uuid:7d06a0e3-a468-11da-8f4c-0011247c532c Format : application/pdf Title : untitled Page Count : 4EXIF Metadata provided by EXIF.tools