AC/300 Call Adapter
Call adaptor.Has one contact switch which is activated by the call.It can be used as an adaptor
relay for installation of,e.g.,acoustic signals or extra sound signals.The appliance can be
installed in a single embedding box (90 x 90 x 40 mm).Supply voltage: from X2 line. Current
demand:20mA max. Max. load to relay contact: 1A,24V (500mA if load is inductive).
Width 60mm
Height 44mm
Depth 16mm
Weight 0.05kg
Module DIN 1
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity 1
Certification CE Yes,certified
Item Details
ICB/300LR Block Selector
The unit,inserted in each block, enables the installation’s common devices (e.g. main
entry panels,porter switchboards,actuators) to be shared by means of one or more
common lines (max.4, one ICB/300 selector for each line).
Width 145mm
Height 105mm
Depth 64.5mm
Weight 0.41kg
Module DIN 6
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity 1
Certification CE Yes,certified
Item Details
IOD/303LR Coded Call Actuator Relay
Remote actuator.The unit is connected to the data bus so that commands can be
received from receivers,such as auxiliary and door lock release commands,and for
controlling relays associated with them.
Width 145mm
Height 70mm
Depth 64.5mm
Weight 0.29kg
Module DIN 4
Minimum working temperature 0ºC
Maximum working temperature +35C
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes,certified
Item Details
IPC/300LR Interface
Item Details
Weight 0.64kg
Minimum package quantity I Certification CE Yes,certified
CONTROL EQUIPMENT
IT/300 230V 50/60Hz Telephone Interface
Telephone interface. Direct access to local line, even during a power cut.Different
entry panel/telephone call ringing tones.Telephone line protected.Programming via
telephone. Supply voltage:230V AC.
Width 145mm
Height 140mm
Depth 64.5mm
Weight 0.83kg
Module DIN 8
Voltage 230V
Frequency 50/60Hz
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified
Item Details
RC/300 Call Repeater
Call Repeater for system 300,X2 and X1.The unit can be used when a call signal must be
heard in a room other than that the receiver is installed in.The repeaters reproduced an
amplified version of the same call note produced by the receiver.Power supplied from X2 bus.
Width 95mm
Height 95mm
Depth 41mm
Weight 0.22kg
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Minimum package quantity I
Certification CE Yes, certified
Item Details
RIR/300LR Echelon Interface Repeater
Width 60mm
Height 44mm
Depth 14mm
Weight 0.05kg
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified
Item Details
VAS/100.20 Power Supplier 230V
Additional power supplier.Supply voltage: 230V.Rated power: 60VA. Output voltage:
17.5V DC,1.7A.
Item Details
Width 210mm
Height 145mm
Depth 64.5mm
Weight 1.57kg
Module DIN 12
Voltage 230V
Frequency 50/60Hz
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified
CONTROL EQUIPMENT
VLS/300 Remote Actuator
Width 70mm
Height 145mm
Depth 64.5mm
Weight 0.22kg
Module DIN 4
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified
Item Details
VSE/300 Selector for Intercom Units
This selector allows the installation of groups of intercom receivers in installation with
standard receivers (system 300).
Depth 16mm
Height 44mm
Width 60mm
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified
Item Details
XA/300LR 230V 50/60Hz Power Supplier and Control Unit
Power supply and control unit operating on ECHELON bus, enables system 300 coded
installations and block-type installations to be created.
Width 210mm
Height 145mm
Depth 64.5mm
Weight 0.95kg
Module DIN 12
Voltage 230V
Current Request R.3.0
Frequency 50/60Hz
Minimum working temperature 0ºC
Maximum working temperature +35ºC
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified
Item Details
CONTROL EQUIPMENT
BPT Security Systems (UK) Ltd,
Unit 16,Sovereign Park,Cleveland Way, Hemel Hempstead,
Hertfordshire,HP2 7DA
Telephone:01442 230800 Fax: 01442 244729
Email:sales@bpt.co.uk Website: www.bpt.co.uk
XAS/300 230V 50/60Hz Power Supplier and Control Unit
Control unit,230V, that regenerate the X2 signals.Can be used in systems 300
and X2.
Item Details
Width 210mm
Height 145mm
Depth 64.5mm
Weight 1.30kg
Module DIN 12
Voltage 230V
Frequency 50/60Hz
Minimum working temperature 0ºC
Maximum working temperature +35C
Mounting type DIN guide
Minimum package quantity I
Certification CE Yes, certified