Y TG Standard Efficiency Single Package Air Conditioners And Gas/Electric Units, DM078 150, 6.5 12.5 PREDATOR DM 078 Tech DM78150 0606
User Manual: PREDATOR DM 078
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
246645-YTG-B-0606 ® TECHNICAL GUIDE ® DESCRIPTION YORK® Predator® units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12-1/2 ton models. All units have two compressors with independent refrigeration circuits to provide two stages of cooling. The units were designed for commercial applications and can be easily installed on a roof curb, slab, or frame. STANDARD EFFICIENCY SINGLE PACKAGE GAS/ELECTRIC UNITS All Predator® units are self-contained and assembled on rigid full perimeter base rails allowing for 3-way forklift access and overhead rigging. Every unit is completely charged, wired, piped, and tested at the factory to provide a quick and easy field installation. DM 078, 090, 102, 120 and 150 6-1/2, 7-1/2, 8-1/2, 10 and 12-1/2 NOMINAL TONS 9.0 EER All units are convertible between side and down airflow. A independent economizer design is used on side and down discharge applications, as well as all tonnage sizes. SINGLE PACKAGE AIR CONDITIONERS AND Predator® units are available in the following configurations: cooling only, cooling with electric heat, and cooling with gas heat. Electric heaters are available as factoryinstalled options or field-installed accessories. Tested in accordance with: FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 246645-YTG-B-0606 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . 5 W/O PWRD CONVENIENCE OUTLET. . . . . . . . . . . . . . . . . 18 11 ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 18 12 ELECTRICAL DATA - DM090 (7-1/2 TON) STANDARD EFFICIENCY W/O PWRD CONV. OUTLET. . . . . . . . . . . . . 19 13 ELECTRICAL DATA - DM090 (7-1/2 TON) STANDARD EFFICIENCY W/PWRD CONV. OUTLET. . . . . . . . . . . . . . . 19 14 ELECTRICAL DATA DM102 (8-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET. . . . . . . . . . . . . . . . . 20 15 ELECTRICAL DATA DM102 (8-1/2 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 20 16 ELECTRICAL DATA DM120 (10 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET. . . . . . . . . . . . . . . . . 21 17 ELECTRICAL DATA DM120 (10 TON) STD EFFICIENCY WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . 21 18 ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/O PWRD CONVENIENCE OUTLET. . . . . . . . . . . . . . . . . 22 FIELD INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . . 6 NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . 46 LIST OF FIGURES Fig. # Pg. # 1 PREDATOR® COMPONENT LOCATION . . . . . . . . . . . . . 3 2 UNIT 4 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 3 UNIT CENTER OF GRAVITY. . . . . . . . . . . . . . . . . . . . . . 35 4 UNIT 6 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6 PREDATOR® ROOF CURB DIMENSIONS . . . . . . . . . . . 37 19 7 SUNLINE™ TO PREDATOR® TRANSITION ROOF CURBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 ELECTRICAL DATA DM150 (12-1/2 TON) STD EFFICIENCY W/PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . 22 20 ELECTRIC HEAT MULTIPLIERS . . . . . . . . . . . . . . . . . . . . . 22 8 BOTTOM DUCT OPENINGS (FROM ABOVE) . . . . . . . . 38 21 9 REAR DUCT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . 39 DM078 (6-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 10 DOWNFLOW ECONOMIZER HOOD DETAIL . . . . . . . . . 39 22 DM090 (7-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 23 DM102 (8-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 11 FACTORY INSTALLED DOWNFLOW ECONOMIZER . . 40 12 FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 13 FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 14 15 16 17 18 24 DM120 (10 TON) SIDE SHOT BLOWER PERFORMANCE 26 25 SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 DM150 (12-1/2 TON) SIDE SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 26 SLAB ECONOMIZER END RETURN W/POWER EXHAUST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 DM078 (6-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 27 COOLING UNIT WITH GAS HEAT WIRING 230 VOLT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 DM090 (7-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 28 COOLING UNIT WITH/WITHOUT ELECTRIC HEAT WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 DM102 (8-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 29 COOLING UNIT WITH GAS HEAT WIRING 460, 575 VOLT AND 50 HZ DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 DM120 (10 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 30 DM150 (12-1/2 TON) DOWN SHOT BLOWER PERFORMANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 31 ADDITIONAL STATIC RESISTANCE DM078, 120 AND 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 32 ADDITIONAL STATIC RESISTANCE DM090, 102 . . . . . . . 33 LIST OF TABLES Tbl. # Pg. # 1 ACCESSORIES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 33 ELECTRIC HEAT MINIMUM SUPPLY AIR CFM . . . . . . . . . 34 2 DM PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 34 INDOOR BLOWER SPECIFICATIONS . . . . . . . . . . . . . . . . 34 3 DM CAPACITY RATINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . .12 35 POWER EXHAUST SPECIFICATIONS . . . . . . . . . . . . . . . . 34 4 UNIT VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . . . .12 36 4 POINT LOAD WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 5 COOLING CAPACITY DM078 (6-1/2 TON) UNIT . . . . . . . . .13 37 6 POINT LOAD WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 6 COOLING CAPACITY DM090 (7-1/2 TON) UNIT . . . . . . . . .14 38 UNIT WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 7 COOLING CAPACITY DM102 (8-1/2 TON) UNIT . . . . . . . . .15 39 UNIT HEIGHT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 8 COOLING CAPACITY DM120 (10 TON) UNIT . . . . . . . . . . .16 40 UNIT CLEARANCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 9 COOLING CAPACITY DM150 (12-1/2 TON) UNIT . . . . . . . .17 41 ECONOMIZER USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 10 ELECTRICAL DATA DM078 (6-1/2 TON) STD EFFICIENCY 2 Unitary Products Group 246645-YTG-B-0606 3FJMIF@FQVFRQWUROERDUG 'LVFRQQHFWORFDWLRQ ZVFUHZFRQQHFWRUIRU7VWDW ZLULQJDQGQHWZRUNFRQQHFWLRQV RSWLRQDOGLVFRQQHFWVZLWFK )LOWHUDFFHVV ´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
Source Exif Data:File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseThumbs XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2006:07:24 13:14:53-05:00 Modify Date : 2006:07:24 13:22:46-05:00 Metadata Date : 2006:07:24 13:22:46-05:00 Format : application/pdf Title : Y-TG-Standard Efficiency Single Package Air Conditioners and Single Package Gas/Electric Units, DM078-150, 6.5-12.5 Creator : amaxwell Document ID : uuid:6351dfb2-a397-4bc5-9dbf-e78208c0d62c Instance ID : uuid:f23e575d-ec4f-4a15-8545-5a96eef28131 Page Count : 48 Page Layout : OneColumn Author : amaxwell Warning : [Minor] Ignored duplicate Info dictionaryEXIF Metadata provided by EXIF.tools