TR9700 Traco Aluminum Windows
User Manual: TR9700
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
08 51 00/TRA BuyLine 1561 Beyond Windows. Beyond Doors.™ Palms Resort, Destin, FL Del Monte Foods, Pittsburgh, PA Architect: Strada Architecture Flat Iron Building, New York, NY Architect: Fifield Piaker Architects Old Dominion University, Norfolk, VA Architect: Clark-Nexsen Architecture and Engineering 08 51 00/TRA BuyLine 1561 Avalon Towers, Mountain View, CA The Streeter Building, Chicago, IL Architect: Solomon Cordwell Benz & Associates Architect: SLCE Architects TRACO products are available with a full range of glass, screen, limit lock and muntin choices. Most products can be curved to meet field conditions. In addition, most aluminum surfaces can be coated with the full range of aluminum finishes including paint conforming to AAMA 2603, AAMA 2604, AAMA 2605 or anodize conforming to AAMA 611. GENERAL CONDITIONS • TRACO recommends that you review with your TRACO representative the design load, jobsite conditions and product configurations before preparing your plans and specifications, as local laws and building codes governing fenestration products vary widely and are subject to interpretation by various building team members. CASEMENT PROJECTED • TRACO drawings and specifications are published as a public service only, and TRACO disclaims all liability for their use, application or adaptation. SLIDING FIXED Warranty: TRACO products carry comprehensive warranties available through your design professional. EXAMPLES OF HISTORIC PANNING AND CUSTOM SURROUNDS SLIDING OR TERRACE DOORS Ma Wt x. Sa . (L sh bs .) th me De p Fra ila TR AC Mo O de lN um “H be C” I r Co mm – H e erc av ial y “C ” 4 or Co – mm erc ial “A W” Ar J – c (O hite pti ct on ur Av al a c ri pt i on DOUBLE OR SINGLE HUNG • TRACO products are covered by a limited warranty, tested to AAMA voluntary specifications, and most are thermally improved to reduce condensation. Field air and water performance may vary with size changes and field conditions. • TRACO reserves the right to change, without prior notice, these drawings and specifications, as TRACO products are constantly modified to meet project requirements. Optional ble ) Standard De s This guide was developed to assist the specifier in choosing the right product for your project based on design pressure and overall performance to ensure a successful and enduring application. AAMA DESIGNATIONS 8/08 Sty le Product Selection Guide Single Hung Side Load Single Hung Side Load Double Hung Side Load Double Hung Side Load Double Hung Side Load Double Hung Tilt Double Hung Tilt Double Hung Tilt Double Hung Tilt Single Hung Tilt Single Hung Tilt Single Hung Tilt TR-9100 TR-9700 TR-9400 TR-9600 TR-9900 NX-500 NX-501 TR-5000 TR-9000 NX-540 NX-541 TR-5400 H-HC40 H-HC40 H-HC50 H-HC80 H-HC65 H-C50 H-HC40 H-C45 H-HC45 H-C50 H-HC40 H-C35 H-AW40 H-AW40 H-AW65 H-AW100 H-AW95 N/A — N/A H-AW45 — — N/A 3-1/4" 3-1/4" 4" 5-1/4" 4-1/2" 3-1/4" 3-1/4" 3-1/4" 4" 3-1/4" 3-1/4" 2-3/4" 70 70 80 150 150 40 60 40 60/80 40 60 40 2-1/4" Overlap Outswing 2-1/4" Overlap Inswing 3-1/4" Overlap Outswing 4-5/8" Flush Outswing 4-5/8" Flush Inswing 2-1/4" Flush Outswing 2-1/4" Flush Inswing 3-1/4" Overlap Outswing 3-1/4" Overlap Inswing 2-1/4" Overlap Project In 2-1/4" Overlap Project Out 3-1/4" Overlap Project Out 4-5/8" Flush Project In 4-5/8" Flush Project Out 2-1/4" Flush Project In 2-1/4" Flush Project Out 3-1/4" Overlap Project In 3-1/4" Overlap Project Out 3-1/4" Overlap Top Hinge Inswing NX-210 NX-220 NX-310 TR-710 TR-720 TR-2100 TR-2200 TR-3100 TR-3200 NX-240 NX-250 NX-350 TR-740 TR-750 TR-2400 TR-2500 TR-3400 TR-3500 TR-3600 C-C50 C-C50 C-HC40*** C-HC70 C-HC80 C-HC70 C-HC80 C-HC80 C-HC80 AP-C50 AP-C50 AP-HC40*** AP-HC80 AP-HC80 AP-HC80 AP-HC80 AP-HC80 AP-HC80 TH-HC50 N/A N/A — C-AW70 C-AW65 C-AW70 C-AW65 C-AW65 C-AW70 N/A N/A — AP-AW80 AP-AW80 AP-AW80 AP-AW80 AP-AW70 AP-AW65 — 2-1/4" 2-1/4" 3-1/4" 4-5/8" 4-5/8" 2-1/4" 2-1/4" 3-1/4" 3-1/4" 2-1/4" 2-1/4" 3-1/4" 4-5/8" 4-5/8" 2-1/4" 2-1/4" 3-1/4" 3-1/4" 3-1/4" 90 90 116 116 116 116 116 90 90 90 90 116 116 116 162 162 162 162 130 3-1/4" Double Slide 3-1/4" Double Slide 4" Double Slide 3-1/4" Single Slide 2-3/4" Single Slide 3-1/4" Single Slide NX-600 TR-6000 TR-6300 NX-640 TR-6400 TR-6800 HS-C50 HS-C45 HS-HC65 HS-C50 HS-C40 HS-HC60 — N/A HS-AW50 — N/A HS-AW50 3-1/4" 3-1/4" 4" 3-1/4" 2-3/4" 3-1/4" 100 100 170 100 100 170 2-1/4" Depth 3-1/4" Depth 3-1/4" Depth 3-1/4" Depth 4-5/8" Depth 2-1/4" Depth 3-1/4" Depth 3-1/4" Depth 2-3/4" Depth 3-1/4" Depth 4" Depth 2 Panel 2 Panel + Transom or 4 Panel 2, 3 or 4 Panel Prehung Outswing Prehung Inswing NX-280 NX-380 NX-740 NX-741 TR-780 TR-2800 TR-3800 TR-7100 TR-7400 TR-7900 TR-9500 NX-840 TR-8300 TR-8410 NX-8910 NX-8920 F-C50 F-HC40*** F-C50 F-HC50 F-AW65 F-AW65 F-AW100 F-HC50 F-C65 F-HC65 F-HC65 SD-C40 — SGD-HC40 ATD-AW50 ATD-AW50 N/A — N/A — N/A N/A N/A F-AW80 N/A F-AW90 F-AW100 — SD-AW50 — — — 2-1/4" 3-1/4" 3-1/4" 3-1/4" 4-5/8" 2-1/4" 3-1/4" 3-1/4" 2-3/4" 3-1/4" 4" 4-3/8" 4-5/8" 4-1/2" 3¼" /4⅝" 3¼" /4⅝" 234 234 234 234 250 250 250 250 234 250 234 208 208 208 250 250 Str u ( ps c t ur f) al .29 .06* .27 .13* .05* .18* .27 .17* .16* .12* .29 .27* 10 15 12 15 10 10 8 7.5 10 10 8 5.25 40 40 50 80 65 50 40 45 45 50 40 35 40 40 50 80 65 50 40 N/A 45 N/A 40 N/A 60 60 75 120 97.5 75 60 67.5 67.5 75 60 52.5 32" x 60" 32" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 60" 36" x 60" 48" x 32" 48" x 32" 60" x 32" HC [60" x 32"] or AW [60" x 36"] HC [60" x 32"] or AW [60" x 36"] HC [60" x 32"] or AW [60" x 36"] HC [60" x 32"] or AW [60" x 36"] HC [60" x 32"] or AW [60" x 36"] HC [60" x 32"] or AW [60" x 36"] 60" x 99" .04* .06* 10 10 50 50 50 50 75 75 .02 .14 .02 .14 .20 .08 .06* .11* 14 12 14 12 12 12 10 10 70 80 70 80 80 80 50 50 70 80 70 80 80 80 N/A N/A 105 120 105 120 120 120 75 75 .14 .08 .14 .08 .10 .30 .06 12 12 12 12 12 12 10 80 80 80 80 80 80 50 80 80 80 80 80 65 50 120 120 120 120 120 120 75 71" x 60" 71" x 60" 99" x 79" 71" x 60" 71" x 60" 99" x 79" .10* .22* .07 .13* .10* .15 12.5 9 10 10 6 10 50 45 65 50 40 60 N/A N/A 65 N/A N/A 60 75 67.5 97.5 75 60 90 .38** .58** .55** .36** .48** .43** 60" x 60" 60" x 72" 60" x 60" 60" x 72" 60" x 99" 60" x 99" 60" x 99" HC [60" x 72"] or AW [60" x 99"] 60" x 60" HC [60" x 72"] or AW [60" x 99"] HC [60" x 72"] or AW [60" x 99"] 96" x 84" 187" x 96" 116" x 94" 48" x 96"**** 48" x 96"**** .03* 10 50 N/A 75 .03* .03 .03 .03 .04 .07* .03* .03 .03 .12* .09 .09 .05 .05 10 10 15 15 15 7.5 10 20 10 6.75 12 6 15 15 50 50 65 65 100 50 65 65 65 40 50 40 50 50 N/A 50 65 60 100 50 N/A 65 N/A N/A 50 N/A 50 50 75 75 97.5 97.5 150 75 97.5 97.5 105 60 75 60 75 75 .33** .32** .31** .51** .51** .67 .57** .36** .47** .48 .37** .38** .38** .41** 62** 62** 63 49** 61** 47** 55 57** 64** 51** 50** 61** 44** 44** 39** 44** 44** 39** .63** .63** 46** 46** 66** 66** 49** 53** 58** 49** 53** 54** 52** 59** 69** 46** 42** 53** .33** 59** 72** .33** .42** 60** 69** .42** 60** 69** .34** .55** .60 .42** .42** .48** .58** 45** 45** TR-7100 TR-7100 TR-9450 TR-9650 TR-9950 NX-740 NX-741 TR-7100 TR-9500 NX-740 NX-741 TR-7400 NX-280 NX-280 NX-380 TR-780 TR-780 TR-2800 TR-2800 TR-3800 TR-3800 NX-280 NX-280 NX-380 TR-780 TR-780 TR-2800 TR-2800 TR-3800 TR-3800 TR-3800 NX-740 TR-7100 TR-9500 NX-740 TR-7400 TR-7100 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A TR-8350 N/A NX-8950 NX-8950 lG la z ed Int eri or Bli nd Ex s ter ior Fla ng e Du a las s Ma tch Fix ing e Fra d me CR F- g 56** 56** 53 ** 50** .47** .38** .38** .41** .48** CR F- f CR e ra m e OPTIONS UV alu th x he igh t 60" x 99" 60" x 99" 60" x 99" 60" x 99" 60" x 99" 56" x 91" 60" x 99" 56" x 91" 60" x 99" 56" x 91" 60" x 99" 56" x 91" w id 08 51 00/TRA BuyLine 1561 PERFORMANCE Air (cf Infilt m/ rat sq ion .ft. ) Wa ter (ps Re f) sis tan ce De sig ( ps n P re s f) su re De fle (ps ctio f) n Pe AA r M 10 A/W 1/I .S. DMA 2/A /CS 44 0-0 A Fra 5 me [Ve or nt ] TEST SIZES • • • • • • • • • • • • • • AAMA DESIGNATIONS J AAMA • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • Includes: ‘Life Cycle’ testing Test Sizes: large sizes, similar to “HC” Design Pressure Min.: 40 psf Purpose: very large openings with heavy use Typical Applications: Educational and Monumental I AAMA Heavy Commercial “HC” Class Includes: sash removal by maintenance personnel only Test Sizes: large sizes Design Pressure Min.: 40 psf Purpose: large openings with heavy use Typical Applications: Educational, Historic Replication 4AAMA • • • • • Architectural “AW” Class • • Commercial “C” Class Includes: heavy duty (not residential) hardware Test Sizes: medium sizes Design Pressure Min.: 30 psf Purpose: medium openings with medium use Typical Applications: Multi-family, Offices * Tested @1.56 psf (all others air infiltration tested @6.24 psf) ** Thermal tested with Low E glass (all others thermal tested with clear glass) *** Testing in progress **** Tested per AAMA/WDMA/ CSA101/I.S.2/ A440-08 TRACO Blast™ Product Selection Guide Configuration Blast Pressure Rating (PSI) Impulse Rating (PSI-mesc) UFC 2002 UFC 2003 GSA Level C 06B3510 3-1/4" Yes Yes O/X 5.8 48.1 • • • Fixed / Project-Out BLAST™ Plus 06B3510 3-1/4" Yes Yes O/X 5.7 47.6 • • • Fixed / Project-Out BLAST™ Plus 06B3510 3-1/4" Yes Yes O/X 12.1 82.2 • • • Fixed / Outswing BLAST™ Plus 06B3012 3-1/4" Yes Yes O/X 5.9 50.4 • • • Fixed BLAST™ Plus 06B3800 3-1/4" Yes Yes O 6.0 48.0 • • • Fixed BLAST™ Plus 06B3800 3-1/4" Yes Yes O 6.0 47.3 • • • Fixed BLAST™ Plus 12B3800 3-1/4" Yes Yes O 11.8 84.4 • • • Fixed 1V1H Muntin BLAST™ Ultra 42B7700 4-1/4" Yes Yes 1V1H 42.0 296.0 • Fixed 1V2H Muntin BLAST™ Ultra 42B7700 4-1/4" Yes Yes 1V2H 42.0 296.0 • Fixed 5V7H Muntin BLAST™ Ultra 42B7700 4-1/4" Yes Yes 5V7H 42.0 296.0 • Fixed 1V1H Muntin BLAST™ Ultra 42B7750 4-1/4" No No 1V1H 42.0 296.0 • Fixed 1V2H Muntin BLAST™ Ultra 42B7750 4-1/4" No No 1V2H 42.0 296.0 • Single Hung BLAST™ Plus 06B9100 3-1/4" Yes Yes O/X 5.9 47.9 Blast Product Series: BLAST™ BLAST™ Plus BLAST™ Max BLAST™ Ultra • • LM Impact Thermal Frame Insulating Glass BLAST™ Plus DoS Embassy Frame Depth Style GSA Level D Blast™ Model Fixed / Project-Out Description Blast™ Product Series BLAST RESISTANT WINDOWS • • • • • • • • • 8/08 DoD Level Performance - 1psi Static GSA Level C and/or D Performance - 4 to 12psi Dynamic Custom Performance Needs - 12 to 40psi Dynamic DoS Level Performance - 40+psi Dynamic HURRCULES™ THERMAL IMPACT WINDOWS AND DOORS Design Pressure Rating PSF Pos+ Design Pressure Rating PSF Neg- Water Test Pressure (PSF) Missile Impact Tested LM/SM*** Frame Depth Test Size Configuration Test Standard FBC I9100 110 110 12 LM/SM 3-1/4” 40” x 84” O/X ASTM Yes Horizontal Sliding I6800 100 100 10 LM/SM 3-1/4” 111” X 63” OXO ASTM Yes Casement Outswing I3100 100 100 15 LM/SM 3-1/4” 36” x 60” X ASTM Yes Description Model # Single Hung WINDOWS Projected Window I3500 100 100 15 LM/SM 3-1/4” 63” x 71-3/4” X ASTM Yes Fixed I3800 100 100 15 SM 3-1/4” 48” x 72” O ASTM Yes Fixed I3800 120 120 15 LM 3-1/4” 48” x 72” O ASTM Yes Sliding Glass Door Terrace Door Outswing Terrace Door Outswing I8300 I8910 I8910 90 95 130 90 110 150 15 18 18 LM LM SM 5” 3-1/4” 3-1/4” 192” x 96” 36” x 94” 36” x 94” OXXO X X ASTM ASTM ASTM Yes Yes Yes DOORS 8/08 Contact us for additional thermally efficient impact products which reflect recent code changes. Biscayne Product Selection Guide Description Style WINDOWS DOORS Model # Design Design Pressure Pressure Rating Rating PSF Pos+ PSF Neg- 08 51 00/TRA BuyLine 1561 WINDOWS AND DOORS Water Test Pressure (PSF) Missile Impact Frame Tested Depth LM/SM*** Size Configuration Dade County NOA FBC Single Hung SH2100 38.54 38.54 6.75 NI 2⅛" 53⅛" x 74¼" O/X Approved Yes Single Hung Side Load SH240 62 62 12 LM 2¾" 53¼" x 74¼" O/X Approved Yes Single Hung Side Load SH440 80 151.8 13 SM 2¾" 53⅛" x 84" O/X Approved Yes Single Hung Side Load Reinforced SH440R 80 151.8* 13 SM 2¾" 53" x 84" O/X Approved Yes Single Hung Side Load SH540 90* 106 13 LM 2¾" 54¼" x 84" O/X Approved Yes Single Hung (TI) SH940 70 70 10 LM 2¾" 48" x 72" O/X Sliding Window HS2100 33* 33* 6.0 or 8 w/ sill riser NI 2⅛" 53⅛" x 50⅝" XO or OX Approved Yes Sliding Window HS2100 20* 20* 6.0 or 8 w/ sill riser NI 2⅛" 109" x 63" XOX or OXO Approved Yes Sliding Window HS242 55 55 13.5 or 16 w/ sill riser LM 2¾" 74" x 63" XO Approved Yes Sliding Window Optional HS242 70 70 13.5 or 16 w/ sill riser LM 2¾" 111" x 63" XOX Approved Yes Sliding Window HS442 100 100 13.5 or 16 w/ sill riser SM 2¾" 111" x 63" XOX Approved Yes Sliding Window HS542 100 90* 13.5 or 16 w/ sill riser LM 2¾" 111" x 63" XOX Approved Yes Sliding Window HS942 50 50 10 LM 2¾" 72" x 60" XO or OX Casement Outswing C1200 80 80 20 LM/SM 2½" 37" x 63" X Approved Yes Fixed PW2100 100.0 106.2 15 NI 2" 36" x 36" O Approved Yes Fixed PW1250 79.9* 79.9* 20 LM 2½" 37" x 74" O Approved Yes Fixed PW245 90 90 30 LM 2¾" 60" x 60" O Approved Yes Fixed PW445 120.0 120.0 20 SM 2¾" 48" x 60" O Approved Yes Fixed Optional ⁷∕" SP PW545 180.0* 112.2 30 LM 2¾" 30" x 60" O Approved Yes Fixed PW945 70 70 10 LM 2¾" 52" x 72" O Sliding Glass Door 248 60** 60** 10.5 LM 5⅜" 143⅞" x 96" OX XO OXO Approved Yes Sliding Glass Door 3000 41.7** 41.7** 9 NI 7¹∕" 227¾" x 96" 0XX0, OXO, XXX, OX, XO, XX Approved Yes Sliding Glass Door SGD8000 72.7** 72.7** 18 SM 5" 168" x 119¼" OXXO, OXO, OX, XO Approved Yes Sliding Glass Door SGD8000 93** 93** 18 LM 5" 192" x 120" OOXXOO, OXXO, OOX, OXO OX, XO Approved Yes 144⅛" x 95¾" XXO, OXO, XO, OX, XX — — — Yes Yes Yes Terrace Door Outswing Doral 3 50* 48.5* 7.5 NI 4" Terrace Door Outswing 300 90 90 13.5 SM 4" 148" x 96" OXXO, OXX, XXO Approved Yes OXO, XO, OX, XX Terrace Door Outswing 300 90 90 13.5 LM 4" 148" x 96" OXXO, OXX, XXO, Approved Yes OXO, XO, OX, XX * Indicates alternative performance available based on sizing and configuration. ** Indicates minimum performance. Alternative DP ratings available based on size and configuration. *** LM = Large Missile; SM = Small Missile; NI = Non-Impact Approved Yes 8/08 Capabilities DESIGN & ENGINEERING TRACO’s design and engineering capabilities are backed by a state-of-the-art computer assisted design and drafting (CADD) system, including 3-dimensional color plotting capability. TESTING Independently supervised and certified in-house testing of TRACO windows and doors in a full -scale test chamber is assurance that the products have the highest performance characteristics. ENGINEERING LAMINATING TRACO installed lamination equipment to satisfy the increasing demand for laminated windows, curtain wall, storefront, entrances and skylights. The additional requirements for added safety and security are particularly evident for educational facilities, government buildings and coastal buildings due to International Building Codes (IBC) changes and recent threats to national security. The equipment is the first of its kind installed in the United States. TRACO has been tempering its own glass in-house as part of a routine production line for more than 20 years. TESTING GLASS INSULATING ANODIZING EXTRUDING TRACO extrudes on three modern presses its entire requirements for the hundreds of aluminum extrusions necessary to offer a complete line of architectural windows and doors. APPLYING FINISHES Anodize The anodizing facility at TRACO utilizes the modern “two-step” process in which the color is deposited deep within the aluminum surface through electrodeposition, thereby reducing the expected color variation to a minimum. GLASS LAMINATING EXTRUDING Clear Anodize (meets AAMA 611) Available in both Class II (.4 mils) and Class I (.7 mils) finishes. Color Anodize (meets AAMA 611) Available only in a Class I (.7 mils) finish, in traditional bronze anodized color choices. HIGH-PERFORMANCE PAINTING Superior finishes, meeting AAMA 2605, high-performance finishes, meeting AAMA 2604 and standard finishes, meeting AAMA 2603, are applied at TRACO in the most modern five-stage pretreatment, four-booth electrostatic spray facility available. GLASS TEMPERING XYZ CUTTER ARCHITECTURAL PAINT COATINGS Headquarters and Manufacturing 71 Progress Avenue • Cranberry Township, PA 16066 (724) 776-7000 • (724) 776 -7014 FAX • (800) 837-7001 market@traco.com • www.traco.com Manufacturing Facilities: Cranberry Township, PA • Johnson City, TN • Bainbridge, GA • Red Oak, IA
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Mode : UseThumbs XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23 Producer : Acrobat Distiller 6.0.1 for Macintosh Modify Date : 2008:12:08 09:46:09-05:00 Create Date : 2008:10:02 13:57:21-04:00 Metadata Date : 2008:12:08 09:46:09-05:00 Document ID : uuid:9f4899ba-90ab-11dd-ad08-0014511021d6 Instance ID : uuid:e702ee97-812a-431d-895f-a17b00f69e76 Format : application/pdf Title : untitled Page Count : 8 Page Layout : TwoColumnRightEXIF Metadata provided by EXIF.tools