Xtp
User Manual: xtp ProSense Sensor Inserts
Open the PDF directly: View PDF
.
Page Count: 4
| Download | |
| Open PDF In Browser | View PDF |
ProSense Temperature Transmitter Probes Part Number XTP Series Temperature Transmitter Probes XTP product insert Rev. 1 71341491 XTP25N-030-N40140F XTP25N-050-N40140F XTP25N-100-N40140F XTP25N-150-N40140F XTP50N-030-N40140F XTP50N-050-N40140F XTP50N-100-N40140F XTP50N-150-N40140F XTP25N-030-0300F XTP25N-050-0300F XTP25N-100-0300F XTP25N-150-0300F XTP50N-030-0300F XTP50N-050-0300F XTP50N-100-0300F XTP50N-150-0300F XTP25N-030-0100C XTP25N-050-0100C XTP25N-100-0100C XTP25N-150-0100C XTP50N-030-0100C XTP50N-050-0100C XTP50N-100-0100C XTP50N-150-0100C Measuring Range* Thread Size Length 30mm 1/4” MNPT 50mm 100mm 150mm -40 to 140°F (-40 to 60°C) 30mm 1/2” MNPT 50mm 100mm 150mm 30mm 1/4” MNPT 50mm 100mm 150mm 0 to 300°F (-17.8 to 148.9°C) 30mm 1/2” MNPT 50mm 100mm 150mm 30mm 1/4” MNPT 50mm 100mm 150mm 0 to 100°C (32 to 212°F) 30mm 1/2” MNPT 50mm 100mm 150mm * Transmitter probes are factory configured and ready for use out of the box. If changes are desired, transmitter probes can be re-configured. See Programming section of these instructions. Installation 1 Safety Instructions Temperature limits 1.1 Designated use 1.2 Installation, commissioning, operation • The device must only be installed, connected and commissioned by qualified and authorized staff (e.g. electrical technicians) strictly adhering to the instructions contained in this manual, the applicable norms, legal regulations and certificates (depending on the application). C 1.3 Operational safety • The device is safely built and tested according to state-of-the-art technology and has left the factory in perfect condition in regards to technical safety. The applicable regulations and European standards have been taken into account. • Please observe the technical data on the nameplate! • The device must only be powered by a power supply unit with a limited energy electric circuit in accordance with IEC 31010-1: “SELV or Class 2 circuit”. • Due to its design, the device is not repairable. When later disposing of the device, please observe local regulations. XTP product insert Rev. 1 Max. Process Temperature 150°C (302°F) 135°C (275°F) 120°C (248°F) 100°C (212°F) Process pressure limits • 1450 psig (100bar) maximum Maximium flow velocity based on insertion length • These authorized staff members must have read and understood this manual and follow the instructions it contains. • Damaged devices must not be put into operation and they must be labeled as defective. Max. Ambient Temperature Up to 25°C (77°F) Up to 40°C (104°F) Up to 60°C (140°F) Up to 85°C (185°F) B L • The device is a compact temperature transmitter probe for the acquisition and conversion of temperature input signals for industrial temperature measurement. A Pipe installation of the XPS Series •A : On angle brackets • B : In smaller pipes, inclined •C : Perpendicular to the direction of flow • L = Insertion Length 1. Seal the process connection with Teflon tape before you screw in the device. 2. Install the device before the process application is started. v (ft/s) v (m/s) 135 40 120 105 90 75 60 45 35 30 25 20 15 30 10 15 5 0 0 M inimum insertion length Lmin = 30mm (1.18 in) L v 0 30 0 1 60 2 90 3 120 150 L (mm) 4 5 L (in) Insertion length, during flow Flow velocity Medium water at T = 50 °C (122 °F) 6 Dimensions mm [inches] Wiring 1 (BN) + 2 (WH) nc 3 (BU) 4 (BK) nc 3 1 3 0V (4-20 mA) 1 10...35 VDC (4-20 mA) - Sourcing Load - 3 4 Sinking Load + Load Load + + - + - POWER SUPPLY POWER SUPPLY 1 Note: Wiring colors are based on AutomationDirect CD12L and CD12M 4-pole cable assemblies. 2 To prevent damage to the device do not overtighten the M12 plug Load Impedance XTP25 Series Units XTP50 Series Units A Dimensions B Load ( ) 1086 10 V Operating Region 35 V 1.18 in [30mm] 3.98 in [101mm] 1.97 in [50mm] 4.76 in [121mm] 3.94 in [100mm] 6.73 in [171mm] RLmax = (Vpowersupply-10V) / 0.023 A (current output) 5.91 in [150mm] 8.70 in [221mm] e.g. (24V - 10V) / 0.023A = 608Ω XTP product insert Rev. 1 Supply Voltage (VDC) Programming Transmitter probes are factory configured and ready for use out of the box. If changes are desired, transmitter probes can be re-configured using the XT-SOFT programming software, available as a free download at www.automationdirect.com, an XT-USB configuration cable and an XT-M12 adapter (purchased separately). Factory Settings Settable Parameters Standard Settings Expanded Settings Service Functions Measuring unit Measuring range (start and end values) Fault condition reaction Output Filter Offset Measurement point identification/TAG Password (Release Code) Output simulation drives output to a fixed value °C/°F -50 to 150°C (-58 to 302°F) maximum range ≤ 3.6 mA or ≥ 21.0 mA 4-20 mA or 20-4 mA 0...8s -9.9 to +9.9°C (-17.8 to 17.8°F) 8 alpha-numeric digits 4 numeric digits Part number dependent Part number dependent ≥ 21mA 4-20 mA 0s 0.0 Test 0000 on/off off XT-SOFT PC Configuration Software XT-USB Configuration Cable XT-M12 Adapter Note: XT-SOFT version 1.27.13.0 or later required for use with the XTP series transmitters XTP Series XTP product insert Rev. 1 71341491 Powered from USB port
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c011 79.156289, 2014/03/31-23:39:12 Create Date : 2016:12:12 15:52:26-05:00 Metadata Date : 2016:12:12 15:52:32-05:00 Modify Date : 2016:12:12 15:52:32-05:00 Creator Tool : Adobe InDesign CC 2014 (Windows) Instance ID : uuid:f5fa4d9a-50da-45a0-9933-5001385d23ad Original Document ID : xmp.did:e13f73ec-950f-8f4c-b048-239c8f48fd60 Document ID : xmp.id:245a6423-24cb-4142-b6f1-765b11585e23 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:1a675fe5-fbcc-1549-9448-0876d17de389 Derived From Document ID : xmp.did:538b81cc-eddf-4647-9a48-eed6a613f35e Derived From Original Document ID: xmp.did:e13f73ec-950f-8f4c-b048-239c8f48fd60 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Windows) History Changed : / History When : 2016:12:12 15:52:26-05:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC 2014 (Windows)EXIF Metadata provided by EXIF.tools