Dorma Z 9000 Series Electric Trim Installation Instructions I9000et 05 09
User Manual: Dorma 9000 Series Electric Trim Installation Instructions Installation Instructions
Open the PDF directly: View PDF .
Page Count: 3
Download | |
Open PDF In Browser | View PDF |
INSTALLATION INSTRUCTIONS 9000 SERIES "ELECTRIC" TRIM INSTRUCTIONS Specifications REQUIRES DORMA ES-100 POWER SUPPLY (Use as large of wire as possible when wiring power supply and trim.) Power supply will handle two (2) pieces of electric trim. Supplies 4 amp in- rush. NOTE: THIS PRODUCT REQUIRES 24VDC. All electric trim is "09" function. Key removable only when locked. Continuous Duty .15 amp hold @ 24VDC See back side for typical wiring diagram. LFSC - Electric Unlock Fail Secure LFSF - Electric Lock Fail Safe Use caution during installation so wires do not get pinched. (See details below.) (Must be ordered per function from factory.) NOTE: Ref. Template T-9021 for door prep. LFSC When solenoid is energized, trim remains in un-locked position. If power is interrupted, ie. fire alarm is activated, solenoid is de-energized and trim is set in locked position. LFSF 3/8" DIA. (10 mm) When solenoid is energized, trim remains in locked position. If power is interrupted, ie. fire alarm is activated, solenoid is de-energized and trim is set in un-locked SOLENOID LEADS position. (NON POLARIZED) 3/8" (10 mm) OUTSIDE FACE ONLY RACEWAY REQUIRED FOR WIRE CONNECTION, AT POWER CONDUIT. WIRES SHOULD NOT PASS THROUGH THE TOUCHBAR AND RAIL TO MAKE CONNECTION. SEE TEMPLATE T-9021 OUTSIDE FACE ONLY RACEWAY REQUIRED FOR WIRE CONNECTION, AT POWER CONDUIT. WIRES SHOULD NOT PASS THROUGH THE TOUCHBAR AND RAIL TO MAKE CONNECTION. SEE TEMPLATE T-9021 3/8" DIA. (10 mm) 3/8" (10 mm) SOLENOID LEADS (NON POLARIZED) 95011790 (1135-61) www.dorma-usa.com I9000ET-1 5/09 TYPICAL WIRING INSTRUCTIONS 9000 SERIES "ELECTRIC" TRIM DORMA MODEL ES100 24 VOLT DC POWER SUPPLY This is a basic wiring diagram, for additional wire diagrams or project specific diagrams contact the DORMA technical service department at 1-800-523-8483. PUSH TO RESET FUSE CIRCUIT BREAKER 3.0 AMP 24VDC 3/4 AMP 120VAC REPLACE WITH 3AG 3/4 AMP SLO-BLOW TYPE FUSE ONLY ZONE 1 OUTPUT TERMINALS ZONE 2 CONTROL SWITCH OUTPUT TERMINALS NO CONTROL SWITCH CONNECTION CAUTION: 1 2 3 4 5 6 7 8 9 10 11 12 TURN OFF 120VAC POWER PRIOR TO MAKING ANY CONNECTIONS TO TERMINALS. From UPS Green Ground Screw Located WHITE (NEUTRAL) BLACK (HOT) GREEN (GROUND) Power Source 120 VAC POWER LINE (1.0 AMP MAX.) On Chassis TO N.C. CONTACTS IN FIRE ALARM CONTROL PANEL. LFSC When solenoid is energized, trim remains in un-locked position. If power is interrupted, ie. fire alarm is activated, solenoid is de-energized and trim is set in locked position. TO N.C. CONTACTS IN FIRE ALARM CONTROL PANEL. LFSF When solenoid is energized, trim remains in locked position. If power is interrupted, ie. fire alarm is activated, solenoid is de-energized and trim is set in un-locked position. www.dorma-usa.com I9000ET-2 5/09
Source Exif Data:
File Type : AI File Type Extension : ai MIME Type : application/vnd.adobe.illustrator PDF Version : 1.6 Linearized : Yes Create Date : 2009:06:04 08:58:59-04:00 Creator : Adobe Illustrator 10.0 Modify Date : 2010:01:07 15:34:47-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2010:01:07 15:34:47-05:00 Creator Tool : Adobe Illustrator 10.0 Format : application/pdf Document ID : uuid:ae64a6ad-7f16-4050-b220-0a8323476ba8 Instance ID : uuid:955e38d0-a52a-4895-843d-4df61d450b71 Producer : Adobe PDF library 5.00 Page Count : 3 For : dorma, dorma Title : Z:\EXIT\TEMPLATE\instructions\usa\9000\2009UPDATES\I9000ET-1update.pdf Bounding Box : 23 6 615 763 AI Creator Version : 10.0 AI Color Usage : Color AI Ruler Units : Inches AI Color Model : RGB AI Target Resolution : 800 AI Num Layers : 19 Container Version : 9 Creator Version : 10 Image Height : 757 Image Width : 592 Image Size : 592x757 Megapixels : 0.448EXIF Metadata provided by EXIF.tools