Ducane Hvac 4Ac13 Users Manual 4AC13B L 100 10 08

4AC13 to the manual 43d57fc0-f846-43b4-aa35-4a93bc0fd08e

2015-02-04

: Ducane-Hvac Ducane-Hvac-4Ac13-Users-Manual-515006 ducane-hvac-4ac13-users-manual-515006 ducane-hvac pdf

Open the PDF directly: View PDF PDF.
Page Count: 6

4AC13 Features and Benefits
Split System Air Conditioner 13
seer
•R410aRefrigerant
•High-qualitycondensercoilwith
coppertubingandenhanced
louveredfinformaximumheat
transfercapacity
•Topdischargedirectshotairaway
fromlivingareaandshrubbery
•Allunitsfactoryruntested
•Availablewithlouveredpanelor
wireguardcoilprotectionoption
•Easyaccesstoelectricalpanels
•Hingedcontrolpanelallowssimple
accesstointernalcomponents
•45-degreeservicevalvesforeasyhook-up
andservice
•Liquidlinefilterdrierineveryunit
(factoryinstalled)
•Chargedfor15feetofinterconnecting
tubing
•Liquidlinefilterdrierinstalledineveryunit
•AllunitsETL,ETLCapprovedandARIlisted
•10yearlimitedpartswarrantyavailable
LModel
BModel
4AC13 Split System Air Conditioner
13
Model Voltage/ Hz/
Phase Voltage
Range
Min.
Circuit
Amp.
Max.
Fuse
(amps)*
Compressor Fan Motor
Refrig.
Charge
(oz.)**
Weight
(lbs.)
Rated
Load
(Amps)
Locked
Rotor
(Amps)
Full Load
Amps
Rated
HP
Nom.
RPM
Wire
Guard/
Louvered
4AC13(B,L)18P-1A 208-230/60/1 197 - 253 11.9 20 9.0 48 0.7 1/10 1075 72 129/139
4AC13(B,L)24P-1A 208-230/60/1 197 - 253 17.5 25 13.4 58.3 0.7 1/10 1075 75 130/140
4AC13(B,L)30P-1A 208-230/60/1 197 - 253 16.7 25 12.8 64 0.7 1/10 1075 98 166/179
4AC13(B,L)36P-1A 208-230/60/1 197 - 253 18.7 30 14.1 77 1.1 1/5 1075 106 172/187
4AC13(B,L)42P-1A 208-230/60/1 197 - 253 23.5 35 17.9 112 1.1 1/5 1075 126 207/229
4AC13(B,L)48P-1A 208-230/60/1 197 - 253 28.3 40 21.8 117 1.1 1/5 1075 140 222/238
4AC13(B,L)60P-1A 208-230/60/1 197 - 253 34.2 50 26.4 134 1.2 1/4 1075 166 239/256
4 AC 13 B/L 24 P - 1 A 
 ModelNumberGuide
Refrigerant – R410a
AC = Condenser
13 - 13 SEER Nominal
Family / Coil Protection
B = Non-Louvered
L = Louvered
Minor Revision Code
Major Revision Code
Voltage
P - 208-230v/60hz
Single Phase
Nominal Capacity
24 - 24,000 Btuh
ElectricalandPhysicalData
* Overcurrent protection device
** Factory charge adequate for 15 feet of line set. Adjust per Installation Instructions
 UnitDimensions&SoundRatings
Model
Dimensions Sound
Ratings
(dBa)
A - width
(in.)
B - depth
(in.)
C - height
(in.)
4AC13(B,L)18P-1A 22.5 22.5 25 76
4AC13(B,L)24P-1A 22.5 22.5 25 76
4AC13(B,L)30P-1A 30 30 25 78
4AC13(B,L)36P-1A 30 30 29 76
4AC13(B,L)42P-1A 30 30 37 78
4AC13(B,L)48P-1A 30 30 29 80
4AC13(B,L)60P-1A 30 30 33 80
4AC13 Split System Air Conditioner
13
Outdoor
Model
Indoor Model
SEER EER
Rated
ARI
Capacity1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor
Metering
Device
Piston or Field
Installed TXV
Factory
Installed TXV
Outdoor Indoor
Suction
Liquid
Req'd
Indoor2
Optional
Indoor
Suction
Liquid
Suction
Liquid
4AC13(B,L)18*
E(C,M,U)1P19NA - 13.00 11.00 18,000 12,800 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01
E(C,M,U)1P18NA - 13.00 11.00 18,000 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01
E(C,H,U)1P23N(NA) - 13.00 11.00 18,100 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01
E(C,M,U)1P24NA - 13.00 11.00 18,000 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01
4AC13(B,L)24*
E(C,H,M,U)1P23N(A,B) - 13.00 11.00 23,400 16,800 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01
E(C,M,U)1P24NA - 13.00 11.00 23,400 16,800 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01
E(C,H,M,U)1P29NA - 13.00 11.00 23,600 17,000 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01
E(C,M,U)1P30N(A,B) - 13.00 11.00 23,400 16,800 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01
4AC13(B,L)30*
E(C,H,M,U)1P29NA - 13.00 11.00 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01
E(C,M,U)1P30N(A,B) - 13.00 11.00 27,600 21,300 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01
E(C,H,M,U)1P36N(A,B,C)) - 13.00 11.00 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01
4AC13(B,L)36*
E(C,H,M,U)1P36N(A,B,C)) - 13.00 11.00 34,000 25,200 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.065 A4TXV02
E(C,H,M,U)1P43N(B,C)) - 13.00 11.00 34,000 25,200 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.065 A4TXV02
4AC13(B,L)42*
E(C,H,M,U)1P43N(B,C)) - 13.00 11.00 39,500 29,600 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02
E(C,H,U)1P49NC - 13.00 11.00 39,500 29,600 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02
4AC13(B,L)48*
E(C,M,U)1P50NC - 13.00 11.00 47,000 33,400 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03
E(C,H,U)1P49NC - 13.00 11.00 47,500 33,700 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03
E(C,U)1P60ND - 13.00 11.00 47,000 33,400 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03
E(C,H,U)1P62NC - 13.00 11.00 47,000 33,400 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03
4AC13(B,L)60*
E(C,H,U)1P62NC - 13.00 11.00 56,000 39,800 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03
E(C,H,U)1P49NC - 13.00 11.00 56,000 39,800 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03
E(C,U)1P60ND - 13.00 11.00 55,500 39,400 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03
CoolingPerformancewithEvaporatorCoils
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2 Required to achieve ARI rating.
4AC13 Split System Air Conditioner
13
Outdoor
Model
Indoor Model
SEER EER
Rated
ARI
Capacity1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor Metering
Device
Piston or Field
Installed TXV
Factory
Installed
TXV
Outdoor Indoor
Suction
Liquid
Req'd
Indoor2
Optional
Indoor
Suction
Liquid
Suction
Liquid
4AC13(B,L)18 RBCS2M18C****P - 13.00 11.50 18,100 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01
RBCS2M24V****P - 14.00 12.00 18,300 13,200 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01
4AC13(B,L)24 RBCS2M24C****T - 13.50 11.00 23,000 16,600 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01
RBCS2M24V****P - 14.00 11.50 23,200 16,700 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01
4AC13(B,L)30 RBCS2M30C****P - 13.50 11.00 28,200 21,200 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01
RBCS2M36V****P - 14.00 12.00 28,600 21,500 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01
4AC13(B,L)36 RBCS2M36C****T - 13.50 11.50 34,200 25,300 1200 3/4 3/8 3/4 3/8 3/4 3/8 0.065 A4TXV02
RBCS2M36V****P - 14.00 12.00 34,400 25,500 1200 3/4 3/8 3/4 3/8 3/4 3/8 0.065 A4TXV02
4AC13(B,L)42 RBCS2M42****P - 13.50 11.00 39,500 29,600 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02
RBCS2M42V****P - 14.00 11.50 40,000 30,000 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02
4AC13(B,L)48 RBCS2M48****P - 13.50 11.00 47,000 33,400 1550 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03
RBCS2M48V****P - 14.00 11.50 47,500 33,700 1550 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03
4AC13(B,L)60 RBCS2M60****P - 13.00 11.00 56,000 39,800 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03
RBCS2M60V****P - 13.50 11.00 56,500 40,100 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03
CoolingPerformancewithAirHandlersandFurnaces
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2 Required to achieve ARI rating.
4AC13 Split System Air Conditioner
13
Outdoor
Model
Indoor
Model
Indoor
Temp
DB/WB
˚F
Outdoor Temp - DB˚F
65 82 95 105 115
Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW
4AC13(B,L)18 EC1P19
85/72 22,700 .59 1.26 20,800 .63 1.48 19,300 .66 1.66 18,300 .68 1.84 17,200 .69 2.02
80/67 22,100 .63 1.25 19,100 .68 1.46 18,000 .71 1.64 16,500 .74 1.82 15,100 .77 2.00
75/63 17,700 .75 1.24 16,600 .77 1.46 15,700 .78 1.63 14,200 .83 1.81 12,700 .87 1.99
4AC13(B,L)24 EC1P23
85/72 28,500 .61 1.65 26,700 .64 1.93 25,400 .66 2.15 23,400 .69 2.39 21,400 .72 2.63
80/67 26,200 .68 1.63 25,200 .70 1.88 23,400 .72 2.13 21,200 .76 2.37 19,000 .80 2.61
75/63 24,400 .70 1.61 22,400 .73 1.89 20,900 .76 2.10 18,800 .81 2.33 16,800 .85 2.57
4AC13(B,L)30 EC1P29
85/72 32,900 .63 1.97 31,800 .65 2.31 30,900 .66 2.57 28,500 .70 2.85 26,100 .74 3.12
80/67 31,000 .70 1.94 29,700 .70 2.25 28,000 .75 2.55 25,600 .79 2.82 23,300 .82 3.09
75/63 29,400 .72 1.92 27,100 .75 2.25 25,300 .78 2.51 23,000 .82 2.77 20,700 .86 3.04
4AC13(B,L)36 EC1P36
85/72 38,000 .58 2.35 36,800 .62 2.76 35,900 .65 3.08 34,000 .69 3.43 32,200 .72 3.79
80/67 36,300 .65 2.33 35,700 .70 2.72 34,000 .74 3.09 31,500 .78 3.41 29,100 .82 3.74
75/63 33,900 .71 2.31 32,200 .74 2.72 31,000 .77 3.04 28,600 .83 3.37 26,100 .88 3.70
4AC13(B,L)42 EC1P42
85/72 49,400 .65 2.76 46,000 .66 3.24 43,300 .67 3.61 40,500 .70 4.02 37,700 .73 4.42
80/67 46,900 .72 2.71 42,200 .73 3.17 39,500 .75 3.59 36,500 .79 3.99 33,600 .82 4.38
75/63 43,700 .72 2.68 41,200 .78 3.16 39,200 .82 3.53 36,400 .83 3.94 33,500 .83 4.34
4AC13(B,L)48 EC1P48
85/72 53,800 .60 3.31 52,100 .62 3.90 50,900 .64 4.35 47,400 .66 4.79 44,600 .68 5.22
80/67 52,100 .68 3.24 49,900 .69 3.76 47,000 .71 4.27 43,600 .74 4.73 40,200 .77 5.19
75/63 49,500 .70 3.21 45,900 .73 3.80 43,200 .75 4.25 40,000 .78 4.69 36,900 .81 5.14
4AC13(B,L)60 EC1P62
85/72 65,300 .61 3.83 62,900 .63 4.56 61,100 .64 5.11 57,400 .66 5.67 53,800 .68 6.23
80/67 62,300 .67 3.79 58,600 .69 4.44 56,000 .71 5.09 52,300 .74 5.64 48,500 .77 6.19
75/63 59,400 .69 3.76 55,100 .72 4.47 51,900 .74 5.02 48,400 .77 4.57 44,900 .80 6.12
CoolingPerformance—ExtendedRatings
4AC13 Split System Air Conditioner
13
 Accessories
Kit Number Description Where Used
14W00 Compressor Sound Cover 4AC13B/L 18, 24, 30, 36
14W01 Compressor Sound Cover 4AC13B/L 42, 48, 60
14W05 Crankcase Heater 4AC13B/L 18, 24, 30, 36
14W04 Crankcase Heater 4AC13B/L 42, 48, 60
12W19 Hard Start Kit 4AC13B/L 18, 24, 30, 36
12W20 Hard Start kit 4AC13B/L 42, 48, 60
A4TX01 TXV 4AC13B/L 18, 24, 30
A4TX02 TXV 4AC13B/L 36, 42
H4TX03 TXV 4AC13B/L 48, 60
14W07 Short Cycle Protection All Units
40K58 Blower Off Delay Kit All Units
14W08 Low Pressure Switch All Units
34M72 Low Ambient Kit All Units
20443001 Liquid Line Solenoid All Units
FormNo.D4AC13B/L-100(10/08) ©2008AlliedAirEnterprisesInc.,aLennoxInternationalInc.Company PrintedintheU.S.A.
www.ducanehvac.com
1-800-448-5872
Allspecificationsandillustrations
subjecttochangewithoutnotice
andwithoutincurringobligations.

Navigation menu