Ducane Hvac 4Ac13 Users Manual 4AC13B L 100 10 08
4AC13 to the manual 43d57fc0-f846-43b4-aa35-4a93bc0fd08e
2015-02-04
: Ducane-Hvac Ducane-Hvac-4Ac13-Users-Manual-515006 ducane-hvac-4ac13-users-manual-515006 ducane-hvac pdf
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
13 Split System Air Conditioner 4AC1 3 seer Features and Benefits • R410a Refrigerant • High-quality condenser coil with copper tubing and enhanced louvered fin for maximum heat transfer capacity • Top discharge directs hot air away from living area and shrubbery • All units factory run tested • Available with louvered panel or wire guard coil protection option L Model • Easy access to electrical panels • Hinged control panel allows simple access to internal components • 45-degree service valves for easy hook-up and service • Liquid line filter drier in every unit (factory installed) • Charged for 15 feet of interconnecting tubing • Liquid line filter drier installed in every unit • All units ETL, ETLC approved and ARI listed • 10 year limited parts warranty available B Model 13 4AC13 Split System Air Conditioner Model Number Guide 4 AC 13 B/L 24 P - 1 A Refrigerant – R410a Minor Revision Code AC = Condenser Major Revision Code 13 - 13 SEER Nominal Voltage P - 208-230v/60hz Single Phase Family / Coil Protection B = Non-Louvered L = Louvered Nominal Capacity 24 - 24,000 Btuh Electrical and Physical Data Compressor Model Voltage/ Hz/ Phase Voltage Range Min. Circuit Amp. Max. Fuse (amps)* 4AC13(B,L)18P-1A 208-230/60/1 197 - 253 11.9 4AC13(B,L)24P-1A 208-230/60/1 197 - 253 4AC13(B,L)30P-1A 208-230/60/1 4AC13(B,L)36P-1A Fan Motor Refrig. Charge (oz.)** Weight (lbs.) Wire Guard/ Louvered Rated Load (Amps) Locked Rotor (Amps) Full Load Amps Rated HP Nom. RPM 20 9.0 48 0.7 1/10 1075 72 129/139 17.5 25 13.4 58.3 0.7 1/10 1075 75 130/140 197 - 253 16.7 25 12.8 64 0.7 1/10 1075 98 166/179 208-230/60/1 197 - 253 18.7 30 14.1 77 1.1 1/5 1075 106 172/187 4AC13(B,L)42P-1A 208-230/60/1 197 - 253 23.5 35 17.9 112 1.1 1/5 1075 126 207/229 4AC13(B,L)48P-1A 208-230/60/1 197 - 253 28.3 40 21.8 117 1.1 1/5 1075 140 222/238 4AC13(B,L)60P-1A 208-230/60/1 197 - 253 34.2 50 26.4 134 1.2 1/4 1075 166 239/256 * Overcurrent protection device ** Factory charge adequate for 15 feet of line set. Adjust per Installation Instructions Unit Dimensions & Sound Ratings Dimensions A - width (in.) B - depth (in.) C - height (in.) Sound Ratings (dBa) 4AC13(B,L)18P-1A 22.5 22.5 25 76 4AC13(B,L)24P-1a 22.5 22.5 25 76 4AC13(B,L)30P-1a 30 30 25 78 4AC13(B,L)36P-1a 30 30 29 76 4AC13(B,L)42P-1a 30 30 37 78 4AC13(B,L)48P-1a 30 30 29 80 4AC13(B,L)60P-1a 30 30 33 80 Model 4AC13 Split System Air Conditioner 13 Cooling Performance with Evaporator Coils 4AC13(B,L)48* 4AC13(B,L)60* Liquid 4AC13(B,L)42* Suction 4AC13(B,L)36* Liquid 4AC13(B,L)30* EER Suction 4AC13(B,L)24* SEER - 13.00 11.00 18,000 12,800 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01 E(C,M,U)1P18NA - 13.00 11.00 18,000 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01 E(C,H,U)1P23N(NA) - 13.00 11.00 18,100 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01 E(C,M,U)1P24NA - 13.00 11.00 18,000 13,000 600 3/4 3/8 3/4 3/8 3/4 3/8 0.053 A4TXV01 E(C,H,M,U)1P23N(A,B) - 13.00 11.00 23,400 16,800 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01 E(C,M,U)1P24NA - 13.00 11.00 23,400 16,800 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01 E(C,H,M,U)1P29NA - 13.00 11.00 23,600 17,000 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01 E(C,M,U)1P30N(a,B) - 13.00 11.00 23,400 16,800 750 3/4 3/8 3/4 3/8 3/4 3/8 0.057 A4TXV01 E(C,H,M,U)1P29NA - 13.00 11.00 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01 E(C,M,U)1P30N(A,B) - 13.00 11.00 27,600 21,300 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01 E(C,H,M,U)1P36N(A,B,C)) - 13.00 11.00 28,000 21,000 1000 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01 E(C,H,M,U)1P36N(A,B,C)) - 13.00 11.00 34,000 25,200 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.065 A4TXV02 E(C,H,M,U)1P43N(B,C)) - 13.00 11.00 34,000 25,200 1200 3/4 3/8 7/8 3/8 3/4 3/8 0.065 A4TXV02 E(C,H,M,U)1P43N(B,C)) - 13.00 11.00 39,500 29,600 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02 E(C,H,U)1P49NC - 13.00 11.00 39,500 29,600 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02 E(C,M,U)1P50NC - 13.00 11.00 47,000 33,400 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03 E(C,H,U)1P49NC - 13.00 11.00 47,500 33,700 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03 E(C,U)1P60ND - 13.00 11.00 47,000 33,400 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03 E(C,H,U)1P62NC - 13.00 11.00 47,000 33,400 1500 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03 E(C,H,U)1P62NC - 13.00 11.00 56,000 39,800 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03 E(C,H,U)1P49NC - 13.00 11.00 56,000 39,800 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03 E(C,U)1P60ND - 13.00 11.00 55,500 39,400 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03 Piston or Field Installed TXV Factory Installed TXV E(C,M,U)1P19NA CFM Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. Required to achieve ARI rating. 1 2 Indoor Rated ARI Capacity1 Liquid 4AC13(B,L)18* Outdoor Rated Sensible Capacity Indoor Metering Device Suction Outdoor Model Refrigerant Line Size Refrigerant Connection Indoor Model Req'd Optional Indoor2 Indoor 13 4AC13 Split System Air Conditioner Cooling Performance with Air Handlers and Furnaces Factory Installed TXV SEER EER Rated ARI Capacity1 Rated Sensible Capacity CFM Suction Liquid Suction Liquid RBCS2M18C****P - 13.00 11.50 18,100 13,000 600 3/4 3/8 3/4 3/8 RBCS2M24V****P - 14.00 12.00 18,300 13,200 600 3/4 3/8 3/4 3/8 RBCS2M24C****T - 13.50 11.00 23,000 16,600 750 3/4 3/8 3/4 RBCS2M24V****P - 14.00 11.50 23,200 16,700 750 3/4 3/8 RBCS2M30C****P - 13.50 11.00 28,200 21,200 1000 3/4 RBCS2M36V****P - 14.00 12.00 28,600 21,500 1000 RBCS2M36C****T - 13.50 11.50 34,200 25,300 Installed TXV 4AC13(B,L)18 4AC13(B,L)24 4AC13(B,L)30 4AC13(B,L)36 4AC13(B,L)42 4AC13(B,L)48 4AC13(B,L)60 RBCS2M36V****P - 14.00 12.00 34,400 25,500 Req'd Indoor2 Optional Indoor 3/4 3/8 0.053 A4TXV01 3/4 3/8 0.053 A4TXV01 3/8 3/4 3/8 0.057 A4TXV01 3/4 3/8 3/4 3/8 0.057 A4TXV01 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01 3/4 3/8 3/4 3/8 3/4 3/8 0.062 A4TXV01 1200 3/4 3/8 3/4 3/8 3/4 3/8 0.065 A4TXV02 1200 3/4 3/8 3/4 3/8 3/4 3/8 0.065 A4TXV02 RBCS2M42****P - 13.50 11.00 39,500 29,600 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02 RBCS2M42V****P - 14.00 11.50 40,000 30,000 1400 7/8 3/8 7/8 3/8 7/8 3/8 0.074 A4TXV02 RBCS2M48****P - 13.50 11.00 47,000 33,400 1550 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03 RBCS2M48V****P - 14.00 11.50 47,500 33,700 1550 7/8 3/8 7/8 3/8 7/8 3/8 0.082 H4TXV03 RBCS2M60****P - 13.00 11.00 56,000 39,800 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03 RBCS2M60V****P - 13.50 11.00 56,500 40,100 1750 7/8 3/8 7/8 3/8 1-1/8 3/8 0.090 H4TXV03 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240. Required to achieve ARI rating. 1 2 Indoor Liquid Piston or Field Outdoor Indoor Metering Device Suction Outdoor Model Refrigerant Line Size Refrigerant Connection Indoor Model 4AC13 Split System Air Conditioner Cooling Performance — Extended Ratings Outdoor Model 4AC13(B,L)18 4AC13(B,L)24 4AC13(B,L)30 4AC13(B,L)36 4AC13(B,L)42 4AC13(B,L)48 4AC13(B,L)60 Indoor Model EC1P19 EC1P23 EC1P29 EC1P36 EC1P42 EC1P48 EC1P62 13 Outdoor Temp - DB˚F Indoor Temp DB/WB ˚F Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW Btuh S/T kW 85/72 22,700 .59 1.26 20,800 .63 1.48 19,300 .66 1.66 18,300 .68 1.84 17,200 .69 2.02 80/67 22,100 .63 1.25 19,100 .68 1.46 18,000 .71 1.64 16,500 .74 1.82 15,100 .77 2.00 75/63 17,700 .75 1.24 16,600 .77 1.46 15,700 .78 1.63 14,200 .83 1.81 12,700 .87 1.99 85/72 28,500 .61 1.65 26,700 .64 1.93 25,400 .66 2.15 23,400 .69 2.39 21,400 .72 2.63 80/67 26,200 .68 1.63 25,200 .70 1.88 23,400 .72 2.13 21,200 .76 2.37 19,000 .80 2.61 75/63 24,400 .70 1.61 22,400 .73 1.89 20,900 .76 2.10 18,800 .81 2.33 16,800 .85 2.57 85/72 32,900 .63 1.97 31,800 .65 2.31 30,900 .66 2.57 28,500 .70 2.85 26,100 .74 3.12 80/67 31,000 .70 1.94 29,700 .70 2.25 28,000 .75 2.55 25,600 .79 2.82 23,300 .82 3.09 75/63 29,400 .72 1.92 27,100 .75 2.25 25,300 .78 2.51 23,000 .82 2.77 20,700 .86 3.04 85/72 38,000 .58 2.35 36,800 .62 2.76 35,900 .65 3.08 34,000 .69 3.43 32,200 .72 3.79 80/67 36,300 .65 2.33 35,700 .70 2.72 34,000 .74 3.09 31,500 .78 3.41 29,100 .82 3.74 75/63 33,900 .71 2.31 32,200 .74 2.72 31,000 .77 3.04 28,600 .83 3.37 26,100 .88 3.70 85/72 49,400 .65 2.76 46,000 .66 3.24 43,300 .67 3.61 40,500 .70 4.02 37,700 .73 4.42 80/67 46,900 .72 2.71 42,200 .73 3.17 39,500 .75 3.59 36,500 .79 3.99 33,600 .82 4.38 75/63 43,700 .72 2.68 41,200 .78 3.16 39,200 .82 3.53 36,400 .83 3.94 33,500 .83 4.34 85/72 53,800 .60 3.31 52,100 .62 3.90 50,900 .64 4.35 47,400 .66 4.79 44,600 .68 5.22 80/67 52,100 .68 3.24 49,900 .69 3.76 47,000 .71 4.27 43,600 .74 4.73 40,200 .77 5.19 75/63 49,500 .70 3.21 45,900 .73 3.80 43,200 .75 4.25 40,000 .78 4.69 36,900 .81 5.14 85/72 65,300 .61 3.83 62,900 .63 4.56 61,100 .64 5.11 57,400 .66 5.67 53,800 .68 6.23 80/67 62,300 .67 3.79 58,600 .69 4.44 56,000 .71 5.09 52,300 .74 5.64 48,500 .77 6.19 75/63 59,400 .69 3.76 55,100 .72 4.47 51,900 .74 5.02 48,400 .77 4.57 44,900 .80 6.12 65 82 95 105 115 13 4AC13 Split System Air Conditioner Accessories Kit Number Description Where Used 14W00 Compressor Sound Cover 4ac13b/l 18, 24, 30, 36 14W01 Compressor Sound Cover 4ac13b/l 42, 48, 60 14W05 Crankcase Heater 4ac13b/l 18, 24, 30, 36 14W04 Crankcase Heater 4ac13b/l 42, 48, 60 12W19 Hard Start Kit 4ac13b/l 18, 24, 30, 36 12W20 Hard Start kit 4ac13b/l 42, 48, 60 A4TX01 TXV 4ac13b/l 18, 24, 30 A4TX02 TXV 4ac13b/l 36, 42 H4TX03 TXV 4ac13b/l 48, 60 14W07 Short Cycle Protection All Units 40K58 Blower Off Delay Kit All Units 14W08 Low Pressure Switch All Units 34M72 Low Ambient Kit All Units 20443001 Liquid Line Solenoid All Units All specifications and illustrations subject to change without notice and without incurring obligations. Form No. D4AC13B/L-100 (10/08) www.ducanehvac.com 1-800-448-5872 ©2008 Allied Air Enterprises Inc., a Lennox International Inc. Company Printed in the U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : 3.1-701 Instance ID : uuid:b2ea5e92-aab5-11dd-a45b-000d9347fcc0 Document ID : adobe:docid:indd:4b87d47e-a8c0-11dd-97bd-f079672b92c3 Rendition Class : proof:pdf Derived From Instance ID : 5b6fb1c5-92eb-11dd-bbac-f68340c856dd Derived From Document ID : adobe:docid:indd:5b6fb1c1-92eb-11dd-bbac-f68340c856dd Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 72.00, 300.00, 300.42, 72.00 Manifest Placed Y Resolution : 300.00, 72.00, 300.00, 300.42, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:D9011965256CDC11BD1FE86AFD360B2B, uuid:3953D192091611DC8E2C9812E83AA528, uuid:6AF62F497C9D11DCAC9C953D1FB3FA96, uuid:FE4AA0B0102611DCA505CF1B327465F8, uuid:8D8F9741ED0EDD11B5EEF6882440C569 Manifest Reference Document ID : uuid:D8011965256CDC11BD1FE86AFD360B2B, uuid:3953D191091611DC8E2C9812E83AA528, uuid:6AF62F487C9D11DCAC9C953D1FB3FA96, uuid:65BD21F2091911DCAFFBAE9EDF4F4982, uuid:8C8F9741ED0EDD11B5EEF6882440C569 Create Date : 2008:10:31 09:50:01-04:00 Modify Date : 2008:11:04 16:15:25-05:00 Metadata Date : 2008:11:04 16:15:25-05:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 9529 bytes, use -b option to extract) Format : application/pdf Title : 4AC13B-L-100-10-08.indd Producer : Adobe PDF Library 8.0 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Count : 6 Page Layout : SinglePage Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools