DynaLock 1030RXBwd 1030 RXB SYSTEM KIT Wiring Diagram 1030RXB

User Manual: DynaLock 1030-RXB SYSTEM KIT Wiring Diagram Wiring Diagram

Open the PDF directly: View PDF PDF.
Page Count: 1

DownloadDynaLock 1030RXBwd 1030-RXB SYSTEM KIT Wiring Diagram 1030RXB-Wiring
Open PDF In BrowserView PDF
DynaLock

1030-RXB SYSTEM KIT
WIRING DIAGRAM

705 Emmett Street Bristol, CT 06010
Tel: (860) 582-4761 Fax: (860) 585-0338

120VAC
60HZ

5324
BLK
RED

1
2
3
4

WHT
JUMPER

WHT

WHT
RED
BLK

WHT

3000
GRN

1 2

GRN

RED

6450
7002

OPERATION:
DOOR IS NORMALLY CLOSED AND LOCKED BY THE 3000 MAGNETIC
LOCK. PUSHING THE 6450 EXIT SENSOR BAR IMMEDIATELY RELEASES
THE MAGNETIC LOCK. OPERATING THE 7002 KEYSWITCH RELEASES
THE MAGNETIC LOCK FOR ACCESS. RETURNING THE KEY TO CENTER
RELOCKS THE DOOR.

