EDMI NC30 Electricity Meter User Manual NC30 V1 0 6

EDMI INTERNATIONAL TRADING (SHANGHAI) CO., LTD Electricity Meter NC30 V1 0 6

User Manual

Download: EDMI NC30 Electricity Meter User Manual NC30  V1 0 6
Mirror Download [FCC.gov]EDMI NC30 Electricity Meter User Manual NC30  V1 0 6
Document ID2252334
Application IDQvb6GiBcFQF/bCI7hlmvow==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize26.77kB (334563 bits)
Date Submitted2014-04-25 00:00:00
Date Available2014-04-25 00:00:00
Creation Date2014-04-16 09:43:35
Producing SoftwarepdfFactory Pro 4.50 (Windows 7 Ultimate x86 Chinese (Simplified))
Document Lastmod0000-00-00 00:00:00
Document TitleNC30 User manual-V1.0.6.doc
Document CreatorpdfFactory Pro www.fineprint.cn
Document Author: lenovo

Single Phase Multi-Tariff ANSI Meter
EDMI NC30
Single Phase Multi-Tariff ANSI Meter
User Manual
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Content
1. Product Description .................................................................................................................................... 1
2. Total kWh Register ...................................................................................................................................... 2
3. Meter Memory ............................................................................................................................................... 2
4. Event Record ................................................................................................................................................ 2
5. LCD display during power off.................................................................................................................... 2
6. Maxim Demand............................................................................................................................................. 2
7. Multi-Tariff energy, maximum 4 tariff (TOU) ............................................................................................ 2
8. Programming Password Protected .......................................................................................................... 2
9. LED indicator ................................................................................................................................................ 3
10. LCD display................................................................................................................................................. 3
10.1.The main symbol explanation: ...................................................................................................... 3
10.2.Normal scroll mode (Table 1) .................................................................................................... 4
10.3. Default Display scroll mode ......................................................................................................... 4
11. Communication Port ................................................................................................................................. 5
12. Dis-connect Relay...................................................................................................................................... 5
13. Wiring Connect........................................................................................................................................... 5
14. Component Descriptions ......................................................................................................................... 6
15. Meter Outline Size...................................................................................................................................... 9
16. Default Parameter Setting ........................................................................................................................ 9
Appendix 1: Specification ............................................................................................................................ 10
Appendix 2: Faceplate .................................................................................................................................. 13
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Single Phase Multi-Tariff ANSI Meter
Version
1.0.2
1.0.3
1.0.4
1.0.5
1.0.6
Date Used
2013.01.06
2013.02.21
2013.06.17
2013.08.20
2014.03.21
Description of Revision
Add New Details
Rename
Add Link optional
Add maxim demand
1. Product Description
Socket type, Outdoor
Complied with C12.1 C12.10 C12.18 C12.19 C12.20
LCD 6+1 Energy display way, Display instantaneous item:Voltage,Current, Active Power.
Communication port: optical port,RS485,RF,and PLC Optional
Max 4 rates can be set, default T1
Max Demand display
2 levels of password
12 months History metering data and 50 events of power on/off and meter reset
Dis-connect Relay optional
The NC30 meter
Figure 1-1 NC30 Meter
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
2. Total kWh Register
The total kWh is displayed on the LCD by 6 digits with one decimal.
The total kWh register range is 000000.0-999999.9 kWh.
3. Meter Memory
The history data can store 12 months .
The history data include: Accumulative total and max 4 rates of Wh[abs(Wh+) + abs(Wh-)];
Accumulative total Wh-.
4. Event Record
The energy meter can record below events with time stamp;total 50 events.
Power on.
Power off.
Reset Energy data.
Reset event log.
Reset [energy data+event log].
5. LCD display during power off
Three display modes(can be set):
1. Always display Accumulative Wh[abs(Wh+)+abs(Wh-)].
2. Displaying Accumulative energy for setting time then no display.
3. No Display.
Default LCD display during power off is Mode 1.
6. Maxim Demand
1.
2.
3.
4.
Record T1 active (abs(Wh+) + abs(Wh-))maxim demand ,T2 active maxim demand,T3active maxim
demand,T4 active maxim demand,and the time of the corresponding maxim demand.
Use the slip mode, demand cycle / slip time <=15 min; demand cycle <=60 min, sliding time < =
demand cycle.
Demand decimal use 4 digits,
Save one historical demand data,and clear the demand data when power energy save auto.
7. Multi-Tariff energy, maximum 4 tariff (TOU)
The meter can be up to 4 tariffs per days. And the time interval can be programmed by software.
Default Tariff is Single Tariff, T1.
8. Programming Password Protected
Meter must first through the password confirmation, then do the programming or other special operations.
There are two meter securities.
Level 1, for all permissions. 1122334455;
Level 2, Read only permission, 1111111111.
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
9. LED indicator
A high light LED is mounted on the front of the meter, it will blink/pulse at a rate proportional to the
measured load if the current through the meter more than starting threshold. The pulse value is identified
on the meters nameplate. The pulse can be used for checking the meter accuracy.
10. LCD display
The meter LCD shows 6+1 digits power consumption in kWh, without backlight. The big size of the digits
(13mm×6mm) and clearly identification of display value make meter reader easily to get the data in
distance.
View direction: 6 o'clock
Polarizer mode: Reflective (long life and UV)
Operating temperature :- 40°C ~ + 80°C
Storage temperature:- 45°C ~ + 85°C
Figure 9-1 LCD symbol
10.1. The main symbol explanation:
Symbol
Explanation
LCD display 7 digits;
The energy display as 6+1 digits.(000000.0~999999.9kWh)
Display kWh energy value & date and time.
Mode 1: Display instantaneous item:Voltage,Current, Active Power.
Mode 2: Display data identification(see table 1)
Disconnect Relay Display
Export/import energy symbol;
Simulation and percentage of energy accumulated comparison to Kh
value
Communication symbol (display when comm)
Program symbol
Current running Tariff indication
Unit of Instantaneous Voltage,
Unit of Instantaneous Current,
Unit of Instantaneous Active Power.
Unit of energy
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
10.2. Normal scroll mode
No. Data Identification
(Table 1)
Normal scroll mode
0.1.0
Import Energy (Tariff 1+Tariff Display)
0.2.0
Import Energy (Tariff 2+Tariff Display)
0.3.0
Import Energy (Tariff 3+Tariff Display)
0.4.0
Import Energy (Tariff 4+Tariff Display)
0.5.0
Import + Export Energy (Tariff 1+Tariff Display)
0.6.0
Import + Export Energy (Tariff 2+Tariff Display)
0.7.0
Import + Export Energy (Tariff 3+Tariff Display)
0.8.0
Import + Export Energy (Tariff 4+Tariff Display)
0.9.0
Import Energy (Total) + Voltage
10
1.0.0
Import Energy (Total) + Current(Total)
11
1.1.0
Import Energy (Total) + Current(I1)
12
1.2.0
Import Energy (Total) + Power
13
1.3.0
Import + Export Energy (Total) + Voltage
14
1.4.0
Import + Export Energy (Total) + Current(Total)
15
1.5.0
Import + Export Energy (Total) + Current(I1)
16
1.6.0
Import + Export Energy (Total) + Power
17
1.7.0
Date
18
1.8.0
19
2.0.1
Time
T1 maxim demand
20
2.0.2
T2 maxim demand
21
2.0.3
T3 maxim demand
22
2.0.4
T4 maxim demand
23
2.1.1
T1 maxim demand Date
24
2.1.2
T2 maxim demand Date
25
2.1.3
T3 maxim demand Date
26
2.1.4
T4 maxim demand Date
27
2.2.1
T1 maxim demand Time
28
2.2.2
T2 maxim demand Time
29
2.2.3
T3 maxim demand Time
30
2.2.4
T4 maxim demand Time
10.3. Default Display scroll mode
No
Status
Power on
Power off
PDF pdfFactory Pro
Normal scroll mode
Import + Export Energy (Total) + Voltage
Import + Export Energy (Total) + Current (I1)
Import + Export Energy (Total) + Power
Import + Export Energy (Total) +Voltage
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
11. Communication Port
No
Optical port
RS485 port
RF
port
PLC
port
explanation
ANSI type 2 with 9600bps
Baud Rate 9600 BPS (Optional)
Optional (RF915MHZ)
Optional
12. Dis-connect Relay
Dis-connect Relay : Optional.
13. Wiring Connect
Figure 12-1
3-wire, 1-phase
Figure12-2 Internal connect
(FM2S without Dis-connect Relay)
Figure 12-4
Figure12-3 Internal connect
(FM2S with Dis-connect Relay)
2-wire, 1-phase
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Figure12-5 Internal connect
(FM2S without Dis-connect Relay)
Figure12-6 Internal connect
(FM1S with Dis-connect Relay)
14. Component Descriptions
The components descriptions of the meter are shown in Figure 13-1~Figure 13-8.
Figure 13-1: Basic NC30 Meter Components FM2S
Figure 13-2:Dis-connect Relay NC30(100A) Meter Components FM2S
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Figure 13-3:Dis-connect Relay NC30(200A) Meter Components FM2S
Figure 13-4: Basic NC30(100A/200,Current Transformer) Meter Components FM1S
Figure 13-5: Basic NC30(100A,Shunt) Meter Components FM1S
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Figure 13-6: Dis-connect Relay NC30(100A,Shunt) Meter Components FM1S
Figure 13-7: Dis-connect Relay NC30(100A,Current Transformer) Meter Components FM1S
Figure 13-8: Dis-connect Relay NC30(200A,Current Transformer) Meter Components FM1S
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
15. Meter Outline Size
Figure 14 Meter Outline Size
16. Default Parameter Setting
Default Tariff setting:
Single rate; T1;
Display alternation:
5 seconds.
Default LCD display during power off:
Accumulative Wh[abs(Wh+)+abs(Wh-)].
LCD Display during power on:
Accumulative Wh[abs(Wh+)+abs(Wh-)]
+Active power/ Voltage/ Current.
Security password:
Level 1: 1122334455;
Level 2: 1111111111.
Meter RTC:
Philippines Time;
Communication Port :
Optical port
Dis-connect Relay:
NO.
Meter No.:
According to the bar code on the meter.
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Appendix 1: Specification
Item
Parameter
ANSI standards complied with
C12.1 C12.10 C12.18 C12.19 C12.20
Accuracy
Meet ANSI C12.10 class 0.5
Mounting
Socket type
FM2S, CL200
Meter type, form designation
and current class
FM2S, CL100
FM1S, CL200
FM1S, CL100
Operating Voltage
80%~120%Un
CL200: 30A
Test Current(TA)
Current
CL100: 15A
Current range that guarantees
accuracy
Starting Current
Test
Confidence
Temperature
Communicat
ion Port
Security
CL200: 0.6~200A (2%TA~Imax)
CL100: 0.3~100A (2%TA~Imax)
CL200: 0.030A
(30mA)
CL100: 0.015A
(15mA)
Frequency
60Hz±5%
Kh
10
Kt
1.0
Power supply type
Transformer type
Current sampling mode
Current transformer
Power Consumption
Voltage circuit: <1W, 5VA
Current circuit: <0.25VA/Each
Immunity to impulse voltage
Surge >8kV(1.2/50US)
Insulation strength
4kV,60Hz for 1 min
Relative humidity
0%~95% no condensation
Operating Temperature
- 40°C ~ + 80°C
Storage and Transportation
Temperature
- 45°C ~ + 85°C
LCD Operating Temperature
- 40°C ~ + 80°C
Clock accuracy
< 0.5 s/d, at 23°C
Battery
Li-SOCI2, 3.6V,1200mAh for clock and LCD display
during power off.
Optical port
ANSI type 2 with 9600bps
RS485 port
Optional
RF
port
Optional
PLC port
Optional
Meter security
2 levels of password:
Class 1:All permissions.
10
PDF pdfFactory Pro
(Un=240V/120V)
www.fineprint.cn
Default:1122334455
Single Phase Multi-Tariff ANSI Meter
Class 2: Read only permission. Default:1111111111
Demand
Maxim demand
Maxim demand ;date; time;
Dis-connect
Relay
15(100)A
30(200)A
Optional
LCD layout and characters &
symbols on LCD's meanings
(Please see 9. LCD Display)
LCD size
54mm x 34mm
LCD biggest characters' size
13.0mm x6.0mm
LCD biggest characters'
segment width
1.7mm
LCD with backlight
No
Number of LCD display digits
Energy display way
6 integers + 1 decimal
Voltage,Current & Active Power
3 digits
Display way
LCD
LCD display item ID
3 (No ID when display voltage,current,and power )
Display interval
5s
Display data update rate
1s
Sign 'Yes' at 'meter
column can be optional
displayed on LCD
data'
Yes
Default LCD display
during power on
Accumulative Wh[abs(Wh+)+abs(Wh-)]+RMS Voltage
Accumulative Wh[abs(Wh+)+abs(Wh-)]+RMS Current
Accumulative Wh[abs(Wh+)+abs(Wh-)]+RMS Power
T1 (Please see 9. LCD Display)
Default LCD display during
power off
Accumulative Wh[abs(Wh+)+abs(Wh-)]
LED
1 LED (Active Energy Pulse),1000imp/kWh
Accumulative total and 4 rates
Yes
of Wh[abs(Wh+)+abs(Wh-)]
Accumulative total and 4 rates
Yes
of (Wh+) and (Wh-)
Meter data
Material
Instantaneous frequency
Yes
Instantaneous
Voltage,Current,Active Power
Yes
Current date & time
Yes
Energy data reset
Yes
History metering data
12 months
Event log
Record latest 50 events (power on,power off,energy
reset events with time stamp)
Single layer of upper cover
Transparent flat face cover
Upper cover
Full Circle; Color White
11
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Optical port metal plate
430 grade stainless steel,thickness min 1.2 (inner)
Number of sealable position
Max 4 rates (each rate's period is
Tariff
Faceplate
programmed by software)
Default rate setup
T1 (Single rate)
Faceplate color
Color:White
Faceplate layout
Refer to Appendix 2
New EDMI logo on faceplate
Serial number
Bar code
MCU
Link
Yes
to be nominated by EDMI
to be nominated by EDMI
39 code
NEC 78F0485;
Outside, inside
optional
12
PDF pdfFactory Pro
www.fineprint.cn
Single Phase Multi-Tariff ANSI Meter
Appendix 2: Faceplate
18
17
16
15
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
10
11
12
13
Windows
Meter type
Number of wires for the metered service
Nominal Voltage
Current Class
Test amperes
Nominal Frequency
ANSI C12.10 Form Number
Watthour constant
Accuracy class
Meter Constant
Optical port
Month and Two digit year of manufacture
EDMI logo / Manufacture of meter
Wiring connect
Utility information and bar code area /Meter serial number
Test constant
Meter Pulse
13
PDF pdfFactory Pro
www.fineprint.cn
14
Single Phase Multi-Tariff ANSI Meter
19.
FCC Caution.
§ 15.19 Labelling requirements.
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
§ 15.21 Information to user.
Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
§ 15.105 Information to the user.
Note: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
14
PDF pdfFactory Pro
www.fineprint.cn

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Title                           : NC30 User manual-V1.0.6.doc
Author                          : lenovo
Creator                         : pdfFactory Pro www.fineprint.cn
Producer                        : pdfFactory Pro 4.50 (Windows 7 Ultimate x86 Chinese (Simplified))
Create Date                     : 2014:04:16 09:43:35+08:00
Page Count                      : 16
Page Layout                     : SinglePage
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AB2ZNC30

Navigation menu