EGATEL SL 820003-02 Satellite Terminal Equipment User Manual Installation Guide 01
EGATEL SL Satellite Terminal Equipment Installation Guide 01
Contents
- 1. Installation Guide 01
- 2. Installation Guide 02
Installation Guide 01
Smart LNB IST- Interactive Satellite Teminal Emulsion Terminal Technical Documentation © EGATEL S.L. | 32901 Ourense, España | www.egatel.es Technical Documentation Interactive Satellite Terminal. Reference: Smart LNB. Printed: January 2016 Edition: E.02 - Laboratory Test ER-0120/2002 This document and all information contained therein it is owned by Egatel S.L. It should not be copied, published or reproduced in whole or in part, without express consent from the owner. Egatel Index 1. INTERACTIVE SATELLITE TERMINAL. SMART LNB. 1.1. 1.2. 1.3. 1.4. 1.5. 1.6. FCC Compliance Technical Features General Description Outdoor Unit. ODU Indoor Unit. IDU Interconection. 2. WEB GUI 2.1. 2.2. 2.3. 2.4. 2.5. 2.6. 2.7. 2.8. Introduction Establishing a connection Wellcome Screen Main Screen Tool bar Block diagram Description of the ODU’s parameters by block Description of the IDU’s block. IST. Interactive Satellite Terminal Smart LNB Egatel CHAPTER 1. 1. IST. Interactive Satellite Terminal Smart LNB INTERACTIVE SATELLITE TERMINAL. SMART LNB. INTERACTIVE SATELLITE TERMINAL. SMART LNB. .........................2 1.1. FCC Compliance ............................................................................................... 2 1.2. Technical Features ........................................................................................... 3 1.3. General Description. ......................................................................................... 4 1.4. Outdoor Unit. ODU. ........................................................................................... 5 1.5. Indoor Unit. IDU. ................................................................................................ 6 1.6. Interconnection. ................................................................................................ 8 Página 1.1 IST. Interactive Satellite Terminal Smart LNB Egatel 1. INTERACTIVE SATELLITE TERMINAL. SMART LNB. 1.1. FCC Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This device works in combination with an off-set horn-fed dish antenna with a maximum gain of 39.4 dB This device has been granted with the following FCC ID: 2AGKM820003-02 Danger: FCC Radio Frequency Exposure Information In order to comply with the FCC RF exposure requirements, it is required to maintain a separation distance between the user and the antenna of 11.76m (antenna main beam) and 27cm (horizontal: -10 degrees off-axis). NOTE: This equipment has been tested and found to comply with the limits for class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: − Reorient or relocate the receiving antenna. − Increase the separation between the equipment and receiver. − Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. − Consult the dealer or an experienced radio/TV technician for help. Page 1.2 Egatel IST. Interactive Satellite Terminal Smart LNB 1.2. Technical Features General Composition……………………………….. Outdoor Unit. ODU. Indoor Unit. IDU. ODU Dimensions (without LNB)……….... 127 x 144 x 77 mm. (L x W x D) IDU Dimensions…………………………… 30 x 150 x 110 mm. (L x W x D) Outdoor Unit. ODU Connectors ……………………………….. F (F), 75Ω: External LNB Connection. F (F), 75Ω: IDU Connection. Control and Management……................. Web GUI. Via IDU. Reception Frequency band……..…………………. Ku Band. Low Band: 10,7 – 11,7 GHz High Band: 11,7 - 12,75 GHz. Transmission Frequency band……..…………………. Ku Band. 13,75 GHz - 14,50 GHz. Maximum output Power………………… 31,5 dBm. Indoor Unit. IDU Connectors………………………………….. F (F), 75 Ω: ODU Connection. F (F), 75 Ω: STB Connection. RJ45: Ethernet. LAN Connection. DC IN. (+30Vdc) Control and Management……................. Web GUI. Page 1.3 Egatel IST. Interactive Satellite Terminal Smart LNB 1.3. General Description. The Smart LNB is an electronic device that opens the door to a new wide range of satellite services. It features the most advanced technology in satellite transmission and it makes use of a high spectrum efficiency modulation for the uplink. This technology allows satellite operators to offer their services in either unconnected or connected areas, at a low cost at the equipment and service level. Its objective is to provide high added value services to traditional satellite broadcasting. − Interactive services: HbbTV, VoD, FB, Twitter, telemetry .…. − High added-value M2M services/ domotics: Home control automation, e-health, connected TV...) The Smart LNB is based on the following devices, all of them provided by Egatel: | Antenna System. Satellite dish and other devices needed for its attachment and pointing. | ODU: Outdoor unit. Installed at the antenna’s arm. | IDU: Indoor unit. Located inside the building. Fig. 1. General Scheme. Page 1.4 IST. Interactive Satellite Terminal Smart LNB Egatel 1.4. Outdoor Unit. ODU. The ODU, Outdoor Unit, is housed in a waterproof case located at the antenna’s arm. It can be connected to an external LNB and it is powered by the IDU. | Interfaces: − F-type connector facing the Indoor Unit. − F-type connector facing the External LNB. Fig. 2. Outdoor Unit. ODU interfaces. | ODU – IDU communication: − Modem Ethernet over coaxial. − Signals: Power supply (Vdc). Bidirectional IP traffic. TV signal. (DVB-S2). DiseqC signalling. | Architecture: The Outdoor Unit consists of three cards: − Down Converter. − Digital process. − Up Converter. (F-SIM Modulation) . Page 1.5 IST. Interactive Satellite Terminal Smart LNB Egatel 1.5. Indoor Unit. IDU. The IDU, Indoor Unit, is located inside the building. Its design is based on a compact and easy-to-use terminal that features the latest Home Plug-AV (HPAV) technology. Fig. 3. Indoor Unit. IDU. | Signalling leds: Led Colour Description Power Green Power supply presence. Link Green Communication between IDU & ODU. Data Coax Yellow Data transfer activity between IDU & ODU. | Interfaces. The Indoor Unit has four ports to interface with the external world: − RJ-45 port to connect the IDU to the user's LAN. (Web GUI). − F-type connector facing the Outdoor Unit. − F-type connector facing the user's Set-Top-Box. − DC port for external 30V power supply. (30V / 2A Desktop AC/DC adapter). Fig. 4. Indoor Unit’s rear panel. Page 1.6 Egatel IST. Interactive Satellite Terminal Smart LNB | Architecture: The Indoor Unit consists of a single card that connects the ODU and the Set-top-box (STB). Its main features are: − It process broadcast and M2M services. − Maintain communication with the ODU through coaxial cable following the HomePlug-AV protocol. − Processes the IP data and route it according to its destination: ODU or user’s LAN. Two-way path: ODU to user’s LAN and user’s LAN to ODU. − Web GUI interface to manage the ODU and IDU. The system is passwordprotected so only the authorized users can access to it. Page 1.7 Egatel IST. Interactive Satellite Terminal Smart LNB 1.6. Interconnection. Fig.5. Interconnection general scheme. * The set top box (STB) is not provided by Egatel. Page 1.8 Egatel CHAPTER 2. 2. IST. Interactive Satellite Terminal Smart LNB WEB GUI. WEB GRAPHICAL USER INTERFACE. WEB GUI.................................................................................................2 2.1. Introduction ....................................................................................................... 2 2.2. Establishing a connection................................................................................ 3 2.3. Welcome Screen ............................................................................................... 4 2.4. Main Screen ....................................................................................................... 5 2.5. Tool bar .............................................................................................................. 6 2.5.1. Home. ....................................................................................................... 6 2.5.2. F-SIM........................................................................................................ 7 2.5.3. System. .................................................................................................... 9 2.5.4. Users ...................................................................................................... 13 2.5.5. Logbook.................................................................................................. 15 2.5.6. Session................................................................................................... 16 2.6. Block diagram ................................................................................................. 17 2.6.1. Description. ............................................................................................ 17 2.6.2. Connection’s general information. .......................................................... 18 2.7. Description of the ODU’s parameters by block. ........................................... 21 2.7.1. External Broadcast LNB ......................................................................... 21 2.7.2. Internal Broadcast LNB .......................................................................... 21 2.7.3. Switch ODU ............................................................................................ 22 2.7.4. Internal Data LNB ................................................................................... 22 2.7.5. Internal DVB-S2 demod ......................................................................... 23 2.7.6. Clock reference ...................................................................................... 24 2.7.7. Transmitter ............................................................................................. 24 2.7.8. IP Protocol .............................................................................................. 27 2.8. Description of the IDU’s block. ...................................................................... 28 Página 2.1 Egatel IST. Interactive Satellite Terminal Smart LNB 2. WEB GUI 2.1. Introduction Egatel has developed a powerful and friendly Web GUI to manage and configure the Smart LNB. It also serves as diagnosis and maintenance tool. The focus has been placed on the ease of use while providing the maximum performance. Fig. 1. Example. Main Menu. | The system is password-protected so only authorized users can access to it. | Main screen shows a diagram displaying the major blocks that form the receiving/transmitting chain. It can be used as a tool for browsing through the different parameters and navigation menus. | The Web Server shows the parameters of ODU and IDU units on the same screen. | The ODU is set to be the gateway of the in-home network and it is configured as DHCP server. In this scenario the IDU acts as a simple IP bridge. Page 2.2 IST. Interactive Satellite Terminal Smart LNB Egatel Example of configuration: − − − − − ODU IP: IP Mask: ODU Sat IP Address: ODU SAT. IP Mask: ODU SAT. Gateway: 192.168.5.1 255.255.255.0 10.102.0.2 255.0.0.0 10.0.0.1 However, default configuration can be modified through the WEB GUI. See ODU / IP Protocol section. 2.2. Establishing a connection | Connect a computer directly to the RJ-45 port of the IDU or | Connect the computer to a Router / Switch that is in turn connected to the RJ-45 port of the IDU. Fig. 2. PC – IDU connection. In both cases, ODU / IP Protocol / ODU RJ-45 port must be set “Disabled”. Page 2.3 IST. Interactive Satellite Terminal Smart LNB Egatel 2.3. Welcome Screen Once the physical connection has been done: | Open a Web browser. | Type the ODU’s IP address. (192.168.5.1 by default). If the connection is successfully, a welcome screen comes up. Fig. 3. Welcome screen. There are three types of users, with different level of access. − Administrator − Manager − Operator Inside the Web GUI, users with different level of access can be configured. See chapter Tool bar / User. To access the Web GUI, each user must have a User name and Password. Example: Super user. Type: Administrator. − User: − Pasword: root. roota. After entering the User and Password, users must press the "Login" button or “Enter”. If the introduced pair of User and Password is correct, the main screen of the Web GUI will be displayed. Page 2.4 Egatel IST. Interactive Satellite Terminal Smart LNB 2.4. Main Screen Fig. 4. View of the Home Menu. (Main Screen). The main screen is divided into the following areas: − Title and toolbar. − Block diagram. − Control panel. Under the title and toolbar, relevant values for transmission and reception are displayed: Tx frequency, Tx output power, Carrier ID, Beam ID and Rx quality. Also, the Alarms, Log data, Monitor, DHCP and Logon blocks can be found besides to those values. The bottom of the screen is divided in three columns, so the parameters of up to three blocks can be visualized at the same time. To access the parameters of any block, just click on the desired block and drag it to one of the three columns of the bottom screen. Then, the parameters of that block will be displayed. Page 2.5 IST. Interactive Satellite Terminal Smart LNB Egatel Buttons: Remove and Apply. o Remove: Press this button to remove the changes made. o Apply: Press it to save the value of a parameter that has been modified. 2.5. Tool bar Fig. 5. Tool bar. The toolbar is in the upper part of the screen and includes six buttons: Home, F-SIM, System, Users, Logbook and Session. Hovering the pointer over any of the buttons, the pointer shape changes into a hand and the button background changes colour. When clicking on any of the buttons, the corresponding control panel will be opened in the lower part of the screen. AUTOREFRESH Button: The “AUTOREFRESH” option is located at the most right part of the navigation bar. − By default, it is activated so the displayed values will be periodically updated. Autorefresh running. − To disable this option, just press the Autorefresh button: Autorefresh stopped. 2.5.1. Home. Clicking on the Home button in any screen of the Web Server, leads to the main screen. It shows the equipment status through a block diagram and the control panels. Page 2.6 IST. Interactive Satellite Terminal Smart LNB Egatel 2.5.2. F-SIM. If the ODU is receiving the F-SIM signalling, the F-SIM tables containing the values read from the incoming stream will be displayed in this menu. The bottom of the screen contains two tabs: "Server Configuration" and "Carrier Configuration". | If user clicks on the "Server Configuration" tab, a list showing the server IDs, IPs, ports, and service class will be displayed. Fig. 6. F-SIM / Server Configuration. Page 2.7 IST. Interactive Satellite Terminal Smart LNB Egatel | If user selects the "Carrier Configuration" tab, all the configured carriers will be listed by ID. For each of them, the general parameters will be shown on the left hand and all the available Service Class for such Carrier ID containing its configuration parameters will be displayed on the right side. Please note that for the Service Class parameters to be displayed, the user must first press on the desired "Serv. Class ID:x" tab. Fig. 7. F-SIM / Carrier Configuration. Page 2.8 IST. Interactive Satellite Terminal Smart LNB Egatel 2.5.3. System. This menu provides information about the System configuration. Fig. 8. System Settings. CONFIGURATION Language Language selection: English (default) / Spanish. Active time (min) Time lasted since the power on of the ODU. CPU temperature (ºC) Temperature of the CPU. Average load It shows the average load in 1, 5 and 15 minutes RAM available (KB) It shows the total RAM space (updated every 30s) RAM free (KB) It shows the free or remaining RAM space (updated every 30s) RAM cache (KB) It shows the RAM cache (updated every 30s) RAM buffer It shows the RAM buffer (updated every 30s) Page 2.9 Egatel IST. Interactive Satellite Terminal Smart LNB On the bottom right of the screen, there are the following parameters. | Port Forwarding (DNAT). Port Forwarding (DNAT) Transfer the Ext. Port of a packet to a new destination (IP address and Internal Port) according to the protocols TCP or/ UDP. Ext. Port | Proto | IP address | Int. Port | Action Add / Del * User Type Operator is not allowed to read or modify these parameters. | Routing Table. Routing Table Destination | Netmask | Gateway | Interface | Metric | Action Add / Del * User Type Operator is not allowed to read or modify these parameters. Page 2.10 IST. Interactive Satellite Terminal Smart LNB Egatel | System Version / Update. Fig. 9. System Version / Update. System version / Update CURRENT VERSIONS FPGA, system version It shows the version of the FPGA FW. CONTROL, system version It shows the version of the Control FW. This is a watch-dog process that re-lunches the system in case of a "fault segmentation" error. INTERFACE, system version It shows the version of the Interface FW. This is the FW of the ODU. WEBSERVER, system version It shows the version of the Webserver FW. This is the FW of the WEB GUI. CONFIGURATION FILE Save. It allows downloading the ODU's configuration file. Page 2.11 IST. Interactive Satellite Terminal Smart LNB Egatel CURRENT VERSIONS (Continuation) SAVE CONF. AS DEFAULT Set. It saves the device’s current configuration as default. RESTORE CONF. AS DEFAULT Set. It loads the device’s default configuration. RESTART processes Set. It restarts the processes. REBOOT system Set. It reboots the system. RESTORE from backup Set. It loads the device’s backup configuration. REFLASH from boot loader Set. It reboots the system and prepares it to upload a new firmware. System Versions / Update This menu lets to load a FILE containing the necessary information to Upgrade software version. | Click on “Select File”. Browse through the file system and select the appropriate file containing the update information. | Click on “Send”. The system sends the update request and, once the installed version is checked, it starts the software update process. Do not modify any parameter during the software update. Please, wait until the software update is complete and do not switch the equipment off. | Once the process is complete, the system will show the message "Uploading system software successful". The new versions will be shown in CURRENT VERSION menu. Page 2.12 IST. Interactive Satellite Terminal Smart LNB Egatel 2.5.4. Users There are three types of users in the system: "Administrator", “Manager” and "Operator". Each one has different level of access. | Administrator: This type of user can read and modify any parameter. Moreover, it can create new users, modify their password and delete users from the system. | Manager: This type of user can read any parameter but is only allowed to modify some of them. − He can add new users (Manager and Operator). − He can delete user type operator. − He cannot change the password of other users, but only his own. | Operator: This type of user can read any parameter but is only allowed to modify some of them. He cannot change the password of other users, but only his own. Fig. 10. Users. (Type: Administrator) Page 2.13 Egatel IST. Interactive Satellite Terminal Smart LNB Users CURRENT USER It allows changing the configuration of the current user. Name It displays user’s name. Type Select the type of user. Administrator / Manager / Operator Password Introduce user’s current password New password Introduce user’s new password Confirm New Password Confirm user’s new password To apply the changes for the modification of configuration of the current user, just press the “Modify” button. NEW USER To apply the changes for adding a new user, just press the “Add” button. Name Sets the user’s name. Type Select the type of the new user. Administrator / Manager / Operator. Password Introduce new user’s password USER LIST On the bottom right of the screen, it is displayed a list containing all the users registered in the system, showing information of their names and type of user. If the current user is an "Administrator" it will be allowed to delete any user of the list simply by pressing the “Delete User”. Fig. 11. Users / Manager. Fig. 12. Users / Operator. Page 2.14 Egatel IST. Interactive Satellite Terminal Smart LNB 2.5.5. Logbook Logbook control pane contains the events occurred in the device. Up to 500 events can be stored. Each event shows: Time, Module, PID, level and message. * User Type Operator or Manager can read these parameters but they cannot modify them. Fig. 13. Logbook. Page 2.15 Egatel IST. Interactive Satellite Terminal Smart LNB 2.5.6. Session This menu serves to logout from the current session. When user enters into this menu, the session automatically expires. Press “OK” button to go back to the welcome and authentication screen. Fig. 14. Session. Page 2.16 IST. Interactive Satellite Terminal Smart LNB Egatel 2.6. Block diagram 2.6.1. Description. The central part of the screen is occupied by a graphical representation of the ODU-IDU pair, so that it is easy to recognize the major constituent blocks. Every block contains its own list of parameters and they can be read or modified to configure the system as desired. Fig. 15. Block diagram. To access the parameters of any block, just click on the desired block and drag it to the bottom of the screen. Then, the parameters of that block will be displayed. The bottom of the screen is divided in three columns, so the parameters of up to three blocks can be visualized at the same time. | Place the pointer on the desired block. | Click and hold the left button of your mouse, dragging the block into the lower part of the window. The block can be dropped into any socket within the lower part of the window (left, middle or right). | Once the block is in the desired position, release the mouse button. The control panel associated to the selected block will now be shown in the socket to which it was dragged. There are parameters that are "read only" (measures, for instance) and others that can be modified. To modify the value of a certain parameter, just set the new one and press the "Apply" button on the lower right of the screen. Page 2.17 IST. Interactive Satellite Terminal Smart LNB Egatel If for some reason the connection is lost, a "Server Offline" message will be displayed in the central part of the screen. Fig. 16. Connection lost message. 2.6.2. Connection’s general information. On the central right hand of the screen, relevant values for TX and RX are displayed: Tx frequency, Tx output power, Carrier ID, Beam ID and RX quality. Also, the Alarms, Log data, Monitor, DHCP and Logon Test blocks can be found beside to those values. Relevant values: Tx Frequency: Transmitter frequency (MHz). Range: 13750.0MHz to 14500.0 Mhz. Tx output power: Transmitter output power. Carrier ID: Beam ID: Rx Es/N0: Carrier identification. Beam Identification. Reception quallity. Range: 30 … -30 dBm. Fig. 17. Connection’s information. Page 2.18 IST. Interactive Satellite Terminal Smart LNB Egatel Alarms: The colour of this button changes according with the connection's state: Blue, Yellow, Red. Alarm possibilities: RF output. External LNB. Internal Broadcast LNB. Internal Data LNB. NCR lock. F-SIM signalling. Alarm ACK retransmissions. Log data: When Log data button is dragged to the bottom of the screen, a control panel shows the following parameters. | Send to Trace Server: On / Off. (User Type: Administrator). | Tracer IP address. | Tracer port. Monitor: State of the recepcion and transmission. | Coaxial link quality: MEASURING / BAD / AVERAGE / GOOD − 0 < Coaxial link quality ≤ 97. BAD Red. − 97 < Coaxial link quality ≤ 120. AVERAGE Orange. − Coaxial link quality > 120. GOOD Green. Coaxial Tx rate Coaxial Rx rate Coaxial link SNR Monitor process SAT Bytes received SAT Packets received SAT Rx packets with errors SAT Rx packets dropped SAT Bytes transmitted SAT Packets transmittes SAT Tx packets with errors SAT Tx packets dropped. ODU Bytes received ODU Packets received ODU Rx packets with errors. ODU Rx packets dropped. ODU Bytes transmitted ODU Packets transmittes ODU Tx packets with errors. ODU Tx packets dropped. mbps mbps dB On / Off bytes/s Pkts/s bytes/s Pkts/s bytes/s Pkts/s bytes/s Pkts/s Page 2.19 IST. Interactive Satellite Terminal Smart LNB Egatel Fig. 18. Alarms, Log data and Monitor. DHCP: Dynamic Host configuration Protocol. (Read only parameters). | Mac Address. | IP Address. Logon Test: Logon Test RL Carrier ID valid RL Beam ID valid Link Budget estimation Send Logoff to server Enable / Disable Valid SET * User Type Operator is not allowed to read these parameters. Fig. 19. DHCP, Logon Test, Monitor. Page 2.20 IST. Interactive Satellite Terminal Smart LNB Egatel 2.7. Description of the ODU’s parameters by block. 2.7.1. External Broadcast LNB All the parameters belonging to this block are "Read Only". They cannot be modified through the Web GUI since the configuration of this LNB is done in the user's STB. Measures Explanation Rx Polarization It shows the current polarization for the External Broadcast LNB. | Linear - Horizontal | Linear - Vertical | Circular - Left (Available in Ku/Ka teminal). | Circular - Right (Available in Ku/Ka teminal). Rx band It shows the used band: | Low. LO 9,75 GHz. | High. LO 10,6 GHz. 2.7.2. Internal Broadcast LNB Parameter LNB Configuration Rx polarization * If LNB Configuration: Set top box, this is a “Read only parameter”. Explanation It shows/sets the current configuration for the internal LNB. | Set top box. | User. It shows/sets the current polarization for the Internal Broadcast LNB. | Linear - Horizontal | Linear - Vertical | Circular - Left (Available in Ku/Ka teminal). | Circular Right (Available in Ku/Ka teminal). If LNB Configuration: Set top box, this is a “read only” parameter. Rx band * If LNB Configuration: Set top box, this is a “Read only parameter”. It shows / sets which band is in use: | Low. LO 9,75 GHz. | High. LO 10,6 GHz. If LNB Configuration: Set top box, this is a “read only” parameter. Page 2.21 IST. Interactive Satellite Terminal Smart LNB Egatel 2.7.3. Switch ODU Parameter Switch to Explanation It sets which LNB will be used for receiving the broadcast services: | External LNB. | Internal LNB. 2.7.4. Internal Data LNB Parameter Explanation Rx polarization It shows/sets the current polarization for receiving the interactive services. | Linear - Horizontal | Linear - Vertical | Circular - Left (Available in Ku/Ka teminal). | Circular Right (Available in Ku/Ka teminal). Rx frequency (MHz) It shows/sets the input frequency for receiving the Interactive services. User must enter the frequency in MHz. Range: 10700.0 … 12750.0 MHz. PIDs extraction It Shows/sets the PIDs extraction. | Auto: PIDs (1…8) and NCR PID (Clock reference) are extracted from the tables of the received TS. | Manual: PIDs must be set manually. Range 0 …8191 User type Operator is no allowed to modify this parameter. Service Name It shows / sets a list of Service names received in NIT table. MPE PIDx (x =1 …8) It shows / sets the PID of the desired MPE packets. Range: 0 … 8191 Measures Read only parameters. Rx band It shows which band is in use: | Low. LO 9,75 GHz. | High. LO 10,6 GHz. Number of services Number or Service names received in NiT table Page 2.22 Egatel IST. Interactive Satellite Terminal Smart LNB 2.7.5. Internal DVB-S2 demod The following parameters are "Read Only" and they are provided by the DVB-S2 demodulator. Measures Status It shows whether the DVB-S2 demodulator is locked or not to the RF input signal. | Locked or Unlocked. Frequency (KHz) Frequency of the signal demodulator is locked to. Input power (dBm) Estimation of the input level, calculated by the DVB-S2 demodulator. Range: 0 … -100 dBm. Es/N0 (dB) Estimation of the Es/N0 level, calculated by the DVB-S2 demodulator. Range: 30 … -30 dB. PER (E-7) Estimation of the PER value calculated by the DVB-S2 demodulator. Symbol rate (Bds) It shows the symbol rate of the DVB-S2 stream. ModCode It shows the modulation and code rate of the DVB-S2 stream. Range: All possible combinations of modulation/code rate supported by the DVB-S2 demodulator. Pilots It shows whether the pilots are being used or not. | ON or OFF. Frame Type of frame that is being used: | Normal or Short Roll-Off (%) It shows the Roll-off factor in use. | 20, 25 or 35. TS Status It indicates the status of the Transport Stream. | OK or Fail. FSIM signalling It indicates whether F-SIM signalling has been detected or not. | Presence or Absence. the DVB-S2 Page 2.23 IST. Interactive Satellite Terminal Smart LNB Egatel 2.7.6. Clock reference Parameter NCR PID Explanation It sets/shows the PID number of the NCR. Range: 0 … 8197 Measures Read only parameters. NCR presence It shows whether the presence of the NCR has been detected or not. | OK or Fail Tx Lock to NCR It informs whether the transmitter clock is locked to the NCR (ie. ready for transmission) or not. | Locked or Unlocked 2.7.7. Transmitter Note: Manager and Operator can read these parameters but they cannot modify them. They only can be varied by the Administrator. Parameter TX ON / OFF Explanation It sets the state of the transmitter: | On | Off Remark: If Tx. Test Mode: None works automatically. Tx On/Off | Enable Need to be logged? (Normal operation). The smart LNB must perform the logon procedure before start transmitting data packets. Disable: This option allows the user to transmit RLE packets without executing the logon procedure. | Enable: This option allows the user to carry out Send Logon/Frames to HUB? the logon procedure with the satellite HUB. Disable: The user can perform the logon procedure with the FSIM HUB simulator. Page 2.24 IST. Interactive Satellite Terminal Smart LNB Egatel Parameter Explanation | Manual: User must set the following modulation TX Configuration parameters: − Tx. Polarization. − Tx. Test mode. − FSIM configure. − Preamble S2. Auto: The modulation parameters are set automatically. TX Polarization If TX Configuration: Manual TX Polarization can be: | Linear – Horizontal. | Linear – Vertical. | Circular - Left (Available in Ku/Ka teminal). | Circular - Right (Available in Ku/Ka teminal). TX Frequency (MHz) If TX Configuration: Manual TX Frequency can be set to: 13750.0MHz … 14500.0 Mhz. Value is expressed in MHz. TX Test Mode If TX Configuration: Manual, TX Test Mode: | CW. | FSIM continuous. | FSIM single. | None. In this case, the smart LNB operates in “Normal Mode”, applying the RLE to the incoming IP packets and transmitting them in a FSIM burst according to the configuration selected in the ”FSIM configure” cell. NOTE: If TX Test Mode: None, the smart LNB needs to be locked to the NCR before transmitting anything. Otherwise it will mute the output. In other modes (CW, FSIM continuous or FSIM single), it is not necessary to be locked to the NCR. Time between burst (ms) This parameter allows changing the space between bursts if the FSIM test continuous mode has been set. Range: 0 … 1.000.000 us. Number of bursts Number of burst to be transmitted in single mode. Range: 1 … 255. Page 2.25 IST. Interactive Satellite Terminal Smart LNB Egatel Parameter Explanation FSIM Configure CRxxxxSFxxxxDSxxx. List of all the possible combination of CR, SF and DS of FSIM modes. Control power (beta) Selection of the control channel gain factor. Range: 0 … 15. OVSF code data These values are used to internally generate either the OVSF codes or the Scrambling code. OVSF code control Scrambling code up Scrambling code down Preamble S1 Preamble S2 They should not be modified, unless these codes are also modified in the demodulator. − OVSF code data: 0 (default). Range: 0 … 512. − OVSF control mode: 1 (default). Range: 0…512 − Scrambling code up. 19988480 (default). − Scrambling code down: 33554431 (default). Index of the preamble signature sequence S1 to be used. (Indicated with "n" in clause 7.2.1 of FSIM PHY Layer specification). Default value: 305. Range: 0 … 65535. Index of the sequence S2 constituting the hierarchical preamble. It indicates which of the 2 complementary sequences will be used. (Defined in clause 7.2.2.1 of F-SIM PHY Layer specification). SEQ1 / SEQ2. Default value: SEQ1. Number of pilots Number of pilots to send within the FSIM burst. Range: 0 … 15. Output power attenuation (dBm) Output power attenuation. Range: 0 … 31. (Steps of 1 dB). Measures Read only parameters. Output power (dBm) Output power of the device. Units: dBm. This value depends on the attenuation set in the “Output power attenuation” cell. Number of bits x burst It shows the resulting number of bits per burst from the current configuration. Number of frames x burst It shows the resulting number of frames per burst from the current configuration. Page 2.26 IST. Interactive Satellite Terminal Smart LNB Egatel 2.7.8. IP Protocol Parameter Explanation ODU Coax IP address It sets/reads the ODU IP address on the coax interface. Format: Xxx.xxx.xxx.xxx Range: 0…255. 0…255. 0…255. 0…255. ODU Coax IP mask It sets/reads the ODU IP mask on the coax interface. Format: Xxx.xxx.xxxx.x ODU DHCP Mode on COAX It shows/sets the DHCP Mode on Coax. | Server | Client | None ODU DHCP range low addr Low address of the DHCP server. It depends on the IP address and IP mask. ODU DHCP range high addr High address of the DHCP server. It depends on the IP address and IP mask. Domain Name Server 1 DNS 1. (Ex. Google public DNS) Domain Name Server 2 DNS 2. (Ex. Google public DNS) ODU RJ-45 port It enables or disables the RJ-45 port of the ODU. | Disable. (Default). | Enable. By default it is disabled, so the access to the Web GUI must be done via the RJ-45 port of the IDU. When this option is enabled, the IDU becomes "invisible" to the ODU. Static Multicast IP addr. It sets/reads the Static multicast IP address. | Format: Xxx.xxx.xxx.xxx Range: 0…255. 0…255. 0…255. 0…255. ODU SAT IP address It sets/reads the ODU IP address on the satellite interface. Format: Xxx.xxx.xxxx ODU SAT IP mask It sets/reads the ODU IP mask on the satellite interface. Format: Xxx.xxx.xxxx ODU SAT Gateway It sets/reads the ODU gateway on the satellite interface. Format: Xxx.xxx.xxxx Note: User Type Operator, can read all the parameters listed above but cannot modify them. Page 2.27 IST. Interactive Satellite Terminal Smart LNB Egatel User Type Manager, can read all the parameters listed buy only can varied some of them: − ODU coax. IP address. − ODU Coax IP mask − ODU DHCP Mode on COAX − ODU DHCP range low addr − ODU DHCP range high addr − Domain Name Server 1 − Domain Name Server 2. Measures Read only parameters ODU MAC address It shows the MAC address of the ODU. SAT MAC address It shows the SAT MAC address. 2.8. Description of the IDU’s block. Parameter Explanation This parameter enables or disables the injection of voltage to the coaxial cable. By default, it is activated. | Enable. (Default). | Disable Psupply injection to coax. User type Operator: Psupply injection to coax: Enable. ATTENTION! By disabling this option, the communication with the ODU will be lost. Page 2.28 Egatel EGATEL S.L. Web: www.egatel.es e-mail: egatel@egatel.es HEADQUARTERS INTERNATIONAL SALES Edificio Egatel Av. Ourense, 1 Parque Tecnolóxico de Galicia 32901 Ourense Tlf.: +34 988 368 118 Fax: +34 988 368 119 C/ Julián Camarillo, 6A - 2ª. 28037 Madrid Tlf: +34 91 788 5070 Fax: +34 91 563 5519 EGATEL FINLAND EGATEL ARGENTINA Vättilänkatu, 4 20708 – Kaarina Turku – Finlandia Tlf: +358 (0) 2 2408444 Av. Santa Fe 1845, piso 4, Oficina B 1123 Buenos Aires Capital Federal Tlef / Fax : + 54 114 816 25 22 EGATEL CHILE EGATEL MEXICO Avda. Presidente Riesco, 5335 - 9ª Planta Santiago de Chile Tlf: +5627143823 Av. Insurgentes Sur 813, Piso 10 Col. Nápoles, México 03810, D.F. Teléfono: +52 55 5536 7178
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : marta Create Date : 2016:02:10 15:19:43+01:00 Modify Date : 2016:02:10 15:20:43+01:00 Subject : Title : XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2016:02:10 15:20:43+01:00 Creator Tool : PDFCreator 1.9.2.0 Format : application/pdf Description : Creator : marta Document ID : uuid:118a55ad-fbb7-4a80-a08e-98295a50883d Instance ID : uuid:3fe7bd31-002c-426e-a658-760282d46c4e Producer : PDFCreator 1.9.2.0 Page Layout : TwoPageLeft Page Count : 40EXIF Metadata provided by EXIF.tools