EGATEL SL 820003-02 Satellite Terminal Equipment User Manual Installation Guide 01

EGATEL SL Satellite Terminal Equipment Installation Guide 01

Contents

Installation Guide 01

Download: EGATEL SL 820003-02 Satellite Terminal Equipment User Manual Installation Guide 01
Mirror Download [FCC.gov]EGATEL SL 820003-02 Satellite Terminal Equipment User Manual Installation Guide 01
Document ID2916187
Application IDx/Wc9N0+pyxJ+K/7FWpUmQ==
Document DescriptionInstallation Guide 01
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize264.83kB (3310403 bits)
Date Submitted2016-03-01 00:00:00
Date Available2016-03-02 00:00:00
Creation Date2016-02-10 15:19:43
Producing SoftwarePDFCreator 1.9.2.0
Document Lastmod2016-02-10 15:20:43
Document TitleInstallation Guide 01
Document CreatorPDFCreator 1.9.2.0
Document Author: marta

Smart LNB
IST- Interactive Satellite Teminal
Emulsion Terminal
Technical Documentation
© EGATEL S.L. | 32901 Ourense, España | www.egatel.es
Technical Documentation
Interactive Satellite Terminal.
Reference: Smart LNB.
Printed: January 2016
Edition: E.02 - Laboratory Test
ER-0120/2002
This document and all information contained therein it is owned by Egatel S.L.
It should not be copied, published or reproduced in whole or in part, without express consent from the owner.
Egatel
Index
1. INTERACTIVE SATELLITE TERMINAL. SMART LNB.
1.1.
1.2.
1.3.
1.4.
1.5.
1.6.
FCC Compliance
Technical Features
General Description
Outdoor Unit. ODU
Indoor Unit. IDU
Interconection.
2. WEB GUI
2.1.
2.2.
2.3.
2.4.
2.5.
2.6.
2.7.
2.8.
Introduction
Establishing a connection
Wellcome Screen
Main Screen
Tool bar
Block diagram
Description of the ODU’s parameters by block
Description of the IDU’s block.
IST. Interactive Satellite Terminal
Smart LNB
Egatel
CHAPTER 1.
1.
IST. Interactive Satellite Terminal
Smart LNB
INTERACTIVE SATELLITE TERMINAL.
SMART LNB.
INTERACTIVE SATELLITE TERMINAL. SMART LNB. .........................2
1.1. FCC Compliance ............................................................................................... 2
1.2. Technical Features ........................................................................................... 3
1.3. General Description. ......................................................................................... 4
1.4. Outdoor Unit. ODU. ........................................................................................... 5
1.5. Indoor Unit. IDU. ................................................................................................ 6
1.6. Interconnection. ................................................................................................ 8
Página 1.1
IST. Interactive Satellite Terminal
Smart LNB
Egatel
1.
INTERACTIVE SATELLITE TERMINAL. SMART LNB.
1.1. FCC Compliance
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that
may cause undesired operation.
This device works in combination with an off-set horn-fed dish antenna with a
maximum gain of 39.4 dB
This device has been granted with the following FCC ID: 2AGKM820003-02
Danger: FCC Radio Frequency Exposure Information
In order to comply with the FCC RF exposure requirements, it is
required to maintain a separation distance between the user and the
antenna of 11.76m (antenna main beam) and 27cm (horizontal: -10
degrees off-axis).
NOTE: This equipment has been tested and found to comply with the limits for class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
− Reorient or relocate the receiving antenna.
− Increase the separation between the equipment and receiver.
− Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
− Consult the dealer or an experienced radio/TV technician for help.
Page 1.2
Egatel
IST. Interactive Satellite Terminal
Smart LNB
1.2. Technical Features
General
Composition……………………………….. Outdoor Unit. ODU.
Indoor Unit. IDU.
ODU Dimensions (without LNB)……….... 127 x 144 x 77 mm. (L x W x D)
IDU Dimensions…………………………… 30 x 150 x 110 mm. (L x W x D)
Outdoor Unit. ODU
Connectors ……………………………….. F (F), 75Ω: External LNB Connection.
F (F), 75Ω: IDU Connection.
Control and Management……................. Web GUI. Via IDU.
Reception
Frequency band……..…………………. Ku Band.
Low Band: 10,7 – 11,7 GHz
High Band: 11,7 - 12,75 GHz.
Transmission
Frequency band……..…………………. Ku Band. 13,75 GHz - 14,50 GHz.
Maximum output Power………………… 31,5 dBm.
Indoor Unit. IDU
Connectors………………………………….. F (F), 75 Ω: ODU Connection.
F (F), 75 Ω: STB Connection.
RJ45: Ethernet. LAN Connection.
DC IN. (+30Vdc)
Control and Management……................. Web GUI.
Page 1.3
Egatel
IST. Interactive Satellite Terminal
Smart LNB
1.3. General Description.
The Smart LNB is an electronic device that opens the door to a new wide range of
satellite services.
It features the most advanced technology in satellite transmission and it makes use
of a high spectrum efficiency modulation for the uplink.
This technology allows satellite operators to offer their services in either unconnected
or connected areas, at a low cost at the equipment and service level.
Its objective is to provide high added value services to traditional satellite
broadcasting.
− Interactive services: HbbTV, VoD, FB, Twitter, telemetry .….
− High added-value M2M services/ domotics: Home control automation, e-health,
connected TV...)
The Smart LNB is based on the following devices, all of them provided by Egatel:
| Antenna System. Satellite dish and other devices needed for its attachment and
pointing.
| ODU: Outdoor unit. Installed at the antenna’s arm.
| IDU: Indoor unit. Located inside the building.
Fig. 1. General Scheme.
Page 1.4
IST. Interactive Satellite Terminal
Smart LNB
Egatel
1.4. Outdoor Unit. ODU.
The ODU, Outdoor Unit, is housed in a waterproof case located at the antenna’s arm.
It can be connected to an external LNB and it is powered by the IDU.
| Interfaces:
− F-type connector facing the Indoor Unit.
− F-type connector facing the External LNB.
Fig. 2. Outdoor Unit. ODU interfaces.
| ODU – IDU communication:
− Modem Ethernet over coaxial.
− Signals:
Power supply (Vdc).
Bidirectional IP traffic.
TV signal. (DVB-S2).
DiseqC signalling.
| Architecture: The Outdoor Unit consists of three cards:
− Down Converter.
− Digital process.
− Up Converter. (F-SIM Modulation) .
Page 1.5
IST. Interactive Satellite Terminal
Smart LNB
Egatel
1.5. Indoor Unit. IDU.
The IDU, Indoor Unit, is located inside the building.
Its design is based on a compact and easy-to-use terminal that features the latest
Home Plug-AV (HPAV) technology.
Fig. 3. Indoor Unit. IDU.
| Signalling leds:
Led
Colour
Description
Power
Green
Power supply presence.
Link
Green
Communication between IDU & ODU.
Data Coax
Yellow
Data transfer activity between IDU & ODU.
| Interfaces. The Indoor Unit has four ports to interface with the external world:
− RJ-45 port to connect the IDU to the user's LAN. (Web GUI).
− F-type connector facing the Outdoor Unit.
− F-type connector facing the user's Set-Top-Box.
− DC port for external 30V power supply. (30V / 2A Desktop AC/DC adapter).
Fig. 4. Indoor Unit’s rear panel.
Page 1.6
Egatel
IST. Interactive Satellite Terminal
Smart LNB
| Architecture: The Indoor Unit consists of a single card that connects the ODU and
the Set-top-box (STB). Its main features are:
− It process broadcast and M2M services.
− Maintain communication with the ODU through coaxial cable following the
HomePlug-AV protocol.
− Processes the IP data and route it according to its destination: ODU or user’s
LAN. Two-way path: ODU to user’s LAN and user’s LAN to ODU.
− Web GUI interface to manage the ODU and IDU. The system is passwordprotected so only the authorized users can access to it.
Page 1.7
Egatel
IST. Interactive Satellite Terminal
Smart LNB
1.6. Interconnection.
Fig.5. Interconnection general scheme.
* The set top box (STB) is not provided by Egatel.
Page 1.8
Egatel
CHAPTER 2.
2.
IST. Interactive Satellite Terminal
Smart LNB
WEB GUI.
WEB GRAPHICAL USER INTERFACE.
WEB GUI.................................................................................................2
2.1. Introduction ....................................................................................................... 2
2.2. Establishing a connection................................................................................ 3
2.3. Welcome Screen ............................................................................................... 4
2.4. Main Screen ....................................................................................................... 5
2.5. Tool bar .............................................................................................................. 6
2.5.1. Home. ....................................................................................................... 6
2.5.2. F-SIM........................................................................................................ 7
2.5.3. System. .................................................................................................... 9
2.5.4. Users ...................................................................................................... 13
2.5.5. Logbook.................................................................................................. 15
2.5.6. Session................................................................................................... 16
2.6. Block diagram ................................................................................................. 17
2.6.1. Description. ............................................................................................ 17
2.6.2. Connection’s general information. .......................................................... 18
2.7. Description of the ODU’s parameters by block. ........................................... 21
2.7.1. External Broadcast LNB ......................................................................... 21
2.7.2. Internal Broadcast LNB .......................................................................... 21
2.7.3. Switch ODU ............................................................................................ 22
2.7.4. Internal Data LNB ................................................................................... 22
2.7.5. Internal DVB-S2 demod ......................................................................... 23
2.7.6. Clock reference ...................................................................................... 24
2.7.7. Transmitter ............................................................................................. 24
2.7.8. IP Protocol .............................................................................................. 27
2.8. Description of the IDU’s block. ...................................................................... 28
Página 2.1
Egatel
IST. Interactive Satellite Terminal
Smart LNB
2. WEB GUI
2.1. Introduction
Egatel has developed a powerful and friendly Web GUI to manage and configure the
Smart LNB. It also serves as diagnosis and maintenance tool.
The focus has been placed on the ease of use while providing the maximum
performance.
Fig. 1. Example. Main Menu.
| The system is password-protected so only authorized users can access to it.
| Main screen shows a diagram displaying the major blocks that form the
receiving/transmitting chain. It can be used as a tool for browsing through the
different parameters and navigation menus.
| The Web Server shows the parameters of ODU and IDU units on the same
screen.
| The ODU is set to be the gateway of the in-home network and it is configured as
DHCP server. In this scenario the IDU acts as a simple IP bridge.
Page 2.2
IST. Interactive Satellite Terminal
Smart LNB
Egatel
Example of configuration:
−
−
−
−
−
ODU IP:
IP Mask:
ODU Sat IP Address:
ODU SAT. IP Mask:
ODU SAT. Gateway:
192.168.5.1
255.255.255.0
10.102.0.2
255.0.0.0
10.0.0.1
However, default configuration can be modified through the WEB GUI. See ODU /
IP Protocol section.
2.2. Establishing a connection
| Connect a computer directly to the RJ-45 port of the IDU or
| Connect the computer to a Router / Switch that is in turn connected to the RJ-45
port of the IDU.
Fig. 2. PC – IDU connection.
In both cases, ODU / IP Protocol / ODU RJ-45 port must be set “Disabled”.
Page 2.3
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.3. Welcome Screen
Once the physical connection has been done:
| Open a Web browser.
| Type the ODU’s IP address. (192.168.5.1 by default).
If the connection is successfully, a welcome screen comes up.
Fig. 3. Welcome screen.
There are three types of users, with different level of access.
− Administrator
− Manager
− Operator
Inside the Web GUI, users with different level of access can be configured. See
chapter Tool bar / User.
To access the Web GUI, each user must have a User name and Password.
Example: Super user. Type: Administrator.
− User:
− Pasword:
root.
roota.
After entering the User and Password, users must press the "Login" button or “Enter”.
If the introduced pair of User and Password is correct, the main screen of the Web
GUI will be displayed.
Page 2.4
Egatel
IST. Interactive Satellite Terminal
Smart LNB
2.4. Main Screen
Fig. 4. View of the Home Menu. (Main Screen).
The main screen is divided into the following areas:
− Title and toolbar.
− Block diagram.
− Control panel.
Under the title and toolbar, relevant values for transmission and reception are
displayed: Tx frequency, Tx output power, Carrier ID, Beam ID and Rx quality.
Also, the Alarms, Log data, Monitor, DHCP and Logon blocks can be found
besides to those values.
The bottom of the screen is divided in three columns, so the parameters of up to
three blocks can be visualized at the same time.
To access the parameters of any block, just click on the desired block and drag it
to one of the three columns of the bottom screen. Then, the parameters of that
block will be displayed.
Page 2.5
IST. Interactive Satellite Terminal
Smart LNB
Egatel
Buttons: Remove and Apply.
o Remove:
Press this button to remove the changes made.
o Apply:
Press it to save the value of a parameter that has been
modified.
2.5. Tool bar
Fig. 5. Tool bar.
The toolbar is in the upper part of the screen and includes six buttons: Home, F-SIM,
System, Users, Logbook and Session.
Hovering the pointer over any of the buttons, the pointer shape changes into a
hand and the button background changes colour.
When clicking on any of the buttons, the corresponding control panel will be
opened in the lower part of the screen.
AUTOREFRESH Button:
The “AUTOREFRESH” option is located at the most right part of the navigation bar.
− By default, it is activated so the displayed values will be periodically updated.
Autorefresh running.
− To disable this option, just press the Autorefresh button: Autorefresh stopped.
2.5.1. Home.
Clicking on the Home button in any screen of the Web Server, leads to the
main screen. It shows the equipment status through a block diagram and the
control panels.
Page 2.6
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.5.2. F-SIM.
If the ODU is receiving the F-SIM signalling, the F-SIM tables containing the
values read from the incoming stream will be displayed in this menu.
The bottom of the screen contains two tabs: "Server Configuration" and
"Carrier Configuration".
| If user clicks on the "Server Configuration" tab, a list showing the server
IDs, IPs, ports, and service class will be displayed.
Fig. 6. F-SIM / Server Configuration.
Page 2.7
IST. Interactive Satellite Terminal
Smart LNB
Egatel
| If user selects the "Carrier Configuration" tab, all the configured carriers
will be listed by ID. For each of them, the general parameters will be
shown on the left hand and all the available Service Class for such Carrier
ID containing its configuration parameters will be displayed on the right
side.
Please note that for the Service Class parameters to be displayed, the
user must first press on the desired "Serv. Class ID:x" tab.
Fig. 7. F-SIM / Carrier Configuration.
Page 2.8
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.5.3. System.
This menu provides information about the System configuration.
Fig. 8. System Settings.
CONFIGURATION
Language
Language selection: English (default) / Spanish.
Active time (min)
Time lasted since the power on of the ODU.
CPU temperature (ºC)
Temperature of the CPU.
Average load
It shows the average load in 1, 5 and 15 minutes
RAM available (KB)
It shows the total RAM space (updated every 30s)
RAM free (KB)
It shows the free or remaining RAM space (updated
every 30s)
RAM cache (KB)
It shows the RAM cache (updated every 30s)
RAM buffer
It shows the RAM buffer (updated every 30s)
Page 2.9
Egatel
IST. Interactive Satellite Terminal
Smart LNB
On the bottom right of the screen, there are the following parameters.
| Port Forwarding (DNAT).
Port Forwarding (DNAT)
Transfer the Ext. Port of a packet to a new destination (IP address and Internal Port)
according to the protocols TCP or/ UDP.
Ext. Port | Proto | IP address | Int. Port | Action
Add / Del
* User Type Operator is not allowed to read or modify these parameters.
| Routing Table.
Routing Table
Destination | Netmask | Gateway | Interface | Metric | Action
Add / Del
* User Type Operator is not allowed to read or modify these parameters.
Page 2.10
IST. Interactive Satellite Terminal
Smart LNB
Egatel
| System Version / Update.
Fig. 9. System Version / Update.
System version / Update
CURRENT VERSIONS
FPGA, system version
It shows the version of the FPGA FW.
CONTROL, system version
It shows the version of the Control FW.
This is a watch-dog process that re-lunches the
system in case of a "fault segmentation" error.
INTERFACE, system version
It shows the version of the Interface FW.
This is the FW of the ODU.
WEBSERVER, system version
It shows the version of the Webserver FW. This
is the FW of the WEB GUI.
CONFIGURATION FILE
Save.
It allows downloading the ODU's configuration
file.
Page 2.11
IST. Interactive Satellite Terminal
Smart LNB
Egatel
CURRENT VERSIONS (Continuation)
SAVE CONF. AS DEFAULT
Set.
It saves the device’s current configuration as
default.
RESTORE CONF. AS
DEFAULT
Set.
It loads the device’s default configuration.
RESTART processes
Set.
It restarts the processes.
REBOOT system
Set.
It reboots the system.
RESTORE from backup
Set.
It loads the device’s backup configuration.
REFLASH from boot loader
Set.
It reboots the system and prepares it to upload a
new firmware.
System Versions / Update
This menu lets to load a FILE containing the necessary information to
Upgrade software version.
| Click on “Select File”. Browse through the file system and select the
appropriate file containing the update information.
| Click on “Send”. The system sends the update request and, once the
installed version is checked, it starts the software update process.
Do not modify any parameter during the software update.
Please, wait until the software update is complete and do not switch the
equipment off.
| Once the process is complete, the system will show the message
"Uploading system software successful". The new versions will be shown
in CURRENT VERSION menu.
Page 2.12
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.5.4. Users
There are three types of users in the system: "Administrator", “Manager” and
"Operator". Each one has different level of access.
| Administrator: This type of user can read and modify any parameter.
Moreover, it can create new users, modify their password
and delete users from the system.
| Manager:
This type of user can read any parameter but is only
allowed to modify some of them.
− He can add new users (Manager and Operator).
− He can delete user type operator.
− He cannot change the password of other users, but
only his own.
| Operator:
This type of user can read any parameter but is only
allowed to modify some of them.
He cannot change the password of other users, but only
his own.
Fig. 10. Users. (Type: Administrator)
Page 2.13
Egatel
IST. Interactive Satellite Terminal
Smart LNB
Users
CURRENT USER
It allows changing the configuration of the
current user.
Name
It displays user’s name.
Type
Select the type of user.
Administrator / Manager / Operator
Password
Introduce user’s current password
New password
Introduce user’s new password
Confirm New Password
Confirm user’s new password
To apply the changes for the modification of configuration of the current user, just
press the “Modify” button.
NEW USER
To apply the changes for adding a new user, just
press the “Add” button.
Name
Sets the user’s name.
Type
Select the type of the new user.
Administrator / Manager / Operator.
Password
Introduce new user’s password
USER LIST
On the bottom right of the screen, it is displayed a list containing all the users
registered in the system, showing information of their names and type of user.
If the current user is an "Administrator" it will be allowed to delete any user of the list
simply by pressing the “Delete User”.
Fig. 11. Users / Manager.
Fig. 12. Users / Operator.
Page 2.14
Egatel
IST. Interactive Satellite Terminal
Smart LNB
2.5.5. Logbook
Logbook control pane contains the events occurred in the device. Up to 500
events can be stored.
Each event shows: Time, Module, PID, level and message.
* User Type Operator or Manager can read these parameters but they cannot
modify them.
Fig. 13. Logbook.
Page 2.15
Egatel
IST. Interactive Satellite Terminal
Smart LNB
2.5.6. Session
This menu serves to logout from the current session. When user enters into
this menu, the session automatically expires.
Press “OK” button to go back to the welcome and authentication screen.
Fig. 14. Session.
Page 2.16
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.6. Block diagram
2.6.1. Description.
The central part of the screen is occupied by a graphical representation of
the ODU-IDU pair, so that it is easy to recognize the major constituent
blocks. Every block contains its own list of parameters and they can be read
or modified to configure the system as desired.
Fig. 15. Block diagram.
To access the parameters of any block, just click on the desired block and
drag it to the bottom of the screen. Then, the parameters of that block will be
displayed.
The bottom of the screen is divided in three columns, so the parameters of
up to three blocks can be visualized at the same time.
| Place the pointer on the desired block.
| Click and hold the left button of your mouse, dragging the block into the
lower part of the window. The block can be dropped into any socket within
the lower part of the window (left, middle or right).
| Once the block is in the desired position, release the mouse button. The
control panel associated to the selected block will now be shown in the
socket to which it was dragged.
There are parameters that are "read only" (measures, for instance) and
others that can be modified. To modify the value of a certain parameter, just
set the new one and press the "Apply" button on the lower right of the screen.
Page 2.17
IST. Interactive Satellite Terminal
Smart LNB
Egatel
If for some reason the connection is lost, a "Server Offline" message will be
displayed in the central part of the screen.
Fig. 16. Connection lost message.
2.6.2. Connection’s general information.
On the central right hand of the screen, relevant values for TX and RX are
displayed: Tx frequency, Tx output power, Carrier ID, Beam ID and RX
quality.
Also, the Alarms, Log data, Monitor, DHCP and Logon Test blocks can be
found beside to those values.
Relevant values:
Tx Frequency:
Transmitter frequency (MHz).
Range: 13750.0MHz to 14500.0 Mhz.
Tx output power:
Transmitter output power.
Carrier ID:
Beam ID:
Rx Es/N0:
Carrier identification.
Beam Identification.
Reception quallity.
Range: 30 … -30 dBm.
Fig. 17. Connection’s information.
Page 2.18
IST. Interactive Satellite Terminal
Smart LNB
Egatel
Alarms: The colour of this button changes according with the connection's
state: Blue, Yellow, Red.
Alarm possibilities:
RF output.
External LNB.
Internal Broadcast LNB.
Internal Data LNB.
NCR lock.
F-SIM signalling.
Alarm ACK retransmissions.
Log data: When Log data button is dragged to the bottom of the screen, a
control panel shows the following parameters.
| Send to Trace Server: On / Off. (User Type: Administrator).
| Tracer IP address.
| Tracer port.
Monitor: State of the recepcion and transmission.
| Coaxial link quality:
MEASURING / BAD / AVERAGE / GOOD
− 0 < Coaxial link quality ≤ 97.
BAD
Red.
− 97 < Coaxial link quality ≤ 120.
AVERAGE Orange.
−
Coaxial link quality > 120.
GOOD
Green.
Coaxial Tx rate
Coaxial Rx rate
Coaxial link SNR
Monitor process
SAT Bytes received
SAT Packets received
SAT Rx packets with errors
SAT Rx packets dropped
SAT Bytes transmitted
SAT Packets transmittes
SAT Tx packets with errors
SAT Tx packets dropped.
ODU Bytes received
ODU Packets received
ODU Rx packets with errors.
ODU Rx packets dropped.
ODU Bytes transmitted
ODU Packets transmittes
ODU Tx packets with errors.
ODU Tx packets dropped.
mbps
mbps
dB
On / Off
bytes/s
Pkts/s
bytes/s
Pkts/s
bytes/s
Pkts/s
bytes/s
Pkts/s
Page 2.19
IST. Interactive Satellite Terminal
Smart LNB
Egatel
Fig. 18. Alarms, Log data and Monitor.
DHCP: Dynamic Host configuration Protocol. (Read only parameters).
| Mac Address.
| IP Address.
Logon Test:
Logon Test
RL Carrier ID valid
RL Beam ID valid
Link Budget estimation
Send Logoff to server
Enable / Disable
Valid
SET
* User Type Operator is not allowed to read these parameters.
Fig. 19. DHCP, Logon Test, Monitor.
Page 2.20
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.7. Description of the ODU’s parameters by block.
2.7.1. External Broadcast LNB
All the parameters belonging to this block are "Read Only". They cannot be
modified through the Web GUI since the configuration of this LNB is done in
the user's STB.
Measures
Explanation
Rx Polarization
It shows the current polarization for the External
Broadcast LNB.
| Linear - Horizontal
| Linear - Vertical
| Circular - Left (Available in Ku/Ka teminal).
| Circular - Right (Available in Ku/Ka teminal).
Rx band
It shows the used band:
| Low. LO 9,75 GHz.
| High. LO 10,6 GHz.
2.7.2. Internal Broadcast LNB
Parameter
LNB Configuration
Rx polarization
* If LNB Configuration: Set top box,
this is a “Read only parameter”.
Explanation
It shows/sets the current configuration for the
internal LNB.
| Set top box.
| User.
It shows/sets the current polarization for the
Internal Broadcast LNB.
| Linear - Horizontal
| Linear - Vertical
| Circular - Left (Available in Ku/Ka teminal).
| Circular Right (Available in Ku/Ka teminal).
If LNB Configuration: Set top box, this is a “read only”
parameter.
Rx band
* If LNB Configuration: Set top box,
this is a “Read only parameter”.
It shows / sets which band is in use:
| Low. LO 9,75 GHz.
| High. LO 10,6 GHz.
If LNB Configuration: Set top box, this is a “read only”
parameter.
Page 2.21
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.7.3. Switch ODU
Parameter
Switch to
Explanation
It sets which LNB will be used for receiving the
broadcast services:
| External LNB.
| Internal LNB.
2.7.4. Internal Data LNB
Parameter
Explanation
Rx polarization
It shows/sets the current polarization for
receiving the interactive services.
| Linear - Horizontal
| Linear - Vertical
| Circular - Left (Available in Ku/Ka teminal).
| Circular Right (Available in Ku/Ka teminal).
Rx frequency (MHz)
It shows/sets the input frequency for receiving
the Interactive services.
User must enter the frequency in MHz.
Range: 10700.0 … 12750.0 MHz.
PIDs extraction
It Shows/sets the PIDs extraction.
| Auto: PIDs (1…8) and NCR PID (Clock
reference) are extracted from the tables of the
received TS.
| Manual: PIDs must be set manually.
Range 0 …8191
User type Operator is no allowed to modify this
parameter.
Service Name
It shows / sets a list of Service names received
in NIT table.
MPE PIDx (x =1 …8)
It shows / sets the PID of the desired MPE
packets.
Range: 0 … 8191
Measures
Read only parameters.
Rx band
It shows which band is in use:
| Low. LO 9,75 GHz.
| High. LO 10,6 GHz.
Number of services
Number or Service names received in NiT table
Page 2.22
Egatel
IST. Interactive Satellite Terminal
Smart LNB
2.7.5. Internal DVB-S2 demod
The following parameters are "Read Only" and they are provided by the
DVB-S2 demodulator.
Measures
Status
It shows whether the DVB-S2 demodulator is
locked or not to the RF input signal.
| Locked or Unlocked.
Frequency (KHz)
Frequency of the signal
demodulator is locked to.
Input power (dBm)
Estimation of the input level, calculated by the
DVB-S2 demodulator.
Range: 0 … -100 dBm.
Es/N0 (dB)
Estimation of the Es/N0 level, calculated by the
DVB-S2 demodulator.
Range: 30 … -30 dB.
PER (E-7)
Estimation of the PER value calculated by the
DVB-S2 demodulator.
Symbol rate (Bds)
It shows the symbol rate of the DVB-S2 stream.
ModCode
It shows the modulation and code rate of the
DVB-S2 stream.
Range:
All
possible
combinations
of
modulation/code rate supported by the DVB-S2
demodulator.
Pilots
It shows whether the pilots are being used or
not.
| ON or OFF.
Frame
Type of frame that is being used:
| Normal or Short
Roll-Off (%)
It shows the Roll-off factor in use.
| 20, 25 or 35.
TS Status
It indicates the status of the Transport Stream.
| OK or Fail.
FSIM signalling
It indicates whether F-SIM signalling has been
detected or not.
| Presence or Absence.
the
DVB-S2
Page 2.23
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.7.6. Clock reference
Parameter
NCR PID
Explanation
It sets/shows the PID number of the NCR.
Range: 0 … 8197
Measures
Read only parameters.
NCR presence
It shows whether the presence of the NCR has
been detected or not.
| OK or Fail
Tx Lock to NCR
It informs whether the transmitter clock is locked
to the NCR (ie. ready for transmission) or not.
| Locked or Unlocked
2.7.7. Transmitter
Note:
Manager and Operator can read these parameters but they cannot
modify them. They only can be varied by the Administrator.
Parameter
TX ON / OFF
Explanation
It sets the state of the transmitter:
| On
| Off
Remark: If Tx. Test Mode: None
works automatically.
Tx On/Off
| Enable
Need to be logged?
(Normal operation). The smart LNB
must perform the logon procedure before start
transmitting data packets.
Disable: This option allows the user to transmit
RLE packets without executing the logon
procedure.
| Enable: This option allows the user to carry out
Send Logon/Frames to HUB?
the logon procedure with the satellite HUB.
Disable: The user can perform the logon
procedure with the FSIM HUB simulator.
Page 2.24
IST. Interactive Satellite Terminal
Smart LNB
Egatel
Parameter
Explanation
| Manual: User must set the following modulation
TX Configuration
parameters:
− Tx. Polarization.
− Tx. Test mode.
− FSIM configure.
− Preamble S2.
Auto: The modulation parameters are set
automatically.
TX Polarization
If TX Configuration: Manual
TX Polarization can be:
| Linear – Horizontal.
| Linear – Vertical.
| Circular - Left (Available in Ku/Ka teminal).
| Circular - Right (Available in Ku/Ka teminal).
TX Frequency (MHz)
If TX Configuration: Manual
TX Frequency can be set to: 13750.0MHz …
14500.0 Mhz.
Value is expressed in MHz.
TX Test Mode
If TX Configuration: Manual,
TX Test Mode:
| CW.
| FSIM continuous.
| FSIM single.
| None. In this case, the smart LNB operates in
“Normal Mode”, applying the RLE to the
incoming IP packets and transmitting them in
a FSIM burst according to the configuration
selected in the ”FSIM configure” cell.
NOTE: If TX Test Mode: None, the smart LNB
needs to be locked to the NCR before
transmitting anything. Otherwise it will mute the
output.
In other modes (CW, FSIM continuous or FSIM
single), it is not necessary to be locked to the
NCR.
Time between burst (ms)
This parameter allows changing the space
between bursts if the FSIM test continuous
mode has been set.
Range: 0 … 1.000.000 us.
Number of bursts
Number of burst to be transmitted in single
mode.
Range: 1 … 255.
Page 2.25
IST. Interactive Satellite Terminal
Smart LNB
Egatel
Parameter
Explanation
FSIM Configure
CRxxxxSFxxxxDSxxx.
List of all the possible combination of CR, SF
and DS of FSIM modes.
Control power (beta)
Selection of the control channel gain factor.
Range: 0 … 15.
OVSF code data
These values are used to internally generate
either the OVSF codes or the Scrambling code.
OVSF code control
Scrambling code up
Scrambling code down
Preamble S1
Preamble S2
They should not be modified, unless these codes
are also modified in the demodulator.
− OVSF code data: 0 (default). Range: 0 … 512.
− OVSF control mode: 1 (default). Range: 0…512
− Scrambling code up. 19988480 (default).
− Scrambling code down: 33554431 (default).
Index of the preamble signature sequence S1 to
be used. (Indicated with "n" in clause 7.2.1 of FSIM PHY Layer specification).
Default value: 305.
Range: 0 … 65535.
Index of the sequence S2 constituting the
hierarchical preamble.
It indicates which of the 2 complementary
sequences will be used. (Defined in clause
7.2.2.1 of F-SIM PHY Layer specification).
SEQ1 / SEQ2.
Default value: SEQ1.
Number of pilots
Number of pilots to send within the FSIM burst.
Range: 0 … 15.
Output power attenuation
(dBm)
Output power attenuation.
Range: 0 … 31. (Steps of 1 dB).
Measures
Read only parameters.
Output power (dBm)
Output power of the device. Units: dBm.
This value depends on the attenuation set in the
“Output power attenuation” cell.
Number of bits x burst
It shows the resulting number of bits per burst
from the current configuration.
Number of frames x burst
It shows the resulting number of frames per
burst from the current configuration.
Page 2.26
IST. Interactive Satellite Terminal
Smart LNB
Egatel
2.7.8. IP Protocol
Parameter
Explanation
ODU Coax IP address
It sets/reads the ODU IP address on the coax
interface.
Format: Xxx.xxx.xxx.xxx
Range: 0…255. 0…255. 0…255. 0…255.
ODU Coax IP mask
It sets/reads the ODU IP mask on the coax
interface.
Format: Xxx.xxx.xxxx.x
ODU DHCP Mode on COAX
It shows/sets the DHCP Mode on Coax.
| Server
| Client
| None
ODU DHCP range low addr
Low address of the DHCP server.
It depends on the IP address and IP mask.
ODU DHCP range high addr
High address of the DHCP server.
It depends on the IP address and IP mask.
Domain Name Server 1
DNS 1. (Ex. Google public DNS)
Domain Name Server 2
DNS 2. (Ex. Google public DNS)
ODU RJ-45 port
It enables or disables the RJ-45 port of the ODU.
| Disable. (Default).
| Enable.
By default it is disabled, so the access to the
Web GUI must be done via the RJ-45 port of the
IDU.
When this option is enabled, the IDU becomes
"invisible" to the ODU.
Static Multicast IP addr.
It sets/reads the Static multicast IP address.
| Format: Xxx.xxx.xxx.xxx
Range: 0…255. 0…255. 0…255. 0…255.
ODU SAT IP address
It sets/reads the ODU IP address on the satellite
interface.
Format: Xxx.xxx.xxxx
ODU SAT IP mask
It sets/reads the ODU IP mask on the satellite
interface. Format: Xxx.xxx.xxxx
ODU SAT Gateway
It sets/reads the ODU gateway on the satellite
interface.
Format: Xxx.xxx.xxxx
Note:
User Type Operator, can read all the parameters listed above but
cannot modify them.
Page 2.27
IST. Interactive Satellite Terminal
Smart LNB
Egatel
User Type Manager, can read all the parameters listed buy only can varied
some of them:
− ODU coax. IP address.
− ODU Coax IP mask
− ODU DHCP Mode on COAX
− ODU DHCP range low addr
− ODU DHCP range high addr
− Domain Name Server 1
− Domain Name Server 2.
Measures
Read only parameters
ODU MAC address
It shows the MAC address of the ODU.
SAT MAC address
It shows the SAT MAC address.
2.8. Description of the IDU’s block.
Parameter
Explanation
This parameter enables or disables the injection
of voltage to the coaxial cable.
By default, it is activated.
| Enable. (Default).
| Disable
Psupply injection to coax.
User type Operator: Psupply injection to
coax: Enable.
ATTENTION!
By
disabling
this
option,
the
communication with the ODU will be
lost.
Page 2.28
Egatel
EGATEL S.L.
Web: www.egatel.es
e-mail: egatel@egatel.es
HEADQUARTERS
INTERNATIONAL SALES
Edificio Egatel
Av. Ourense, 1
Parque Tecnolóxico de Galicia
32901 Ourense
Tlf.: +34 988 368 118
Fax: +34 988 368 119
C/ Julián Camarillo, 6A - 2ª.
28037 Madrid
Tlf: +34 91 788 5070
Fax: +34 91 563 5519
EGATEL FINLAND
EGATEL ARGENTINA
Vättilänkatu, 4
20708 – Kaarina
Turku – Finlandia
Tlf: +358 (0) 2 2408444
Av. Santa Fe 1845, piso 4, Oficina B
1123 Buenos Aires Capital Federal
Tlef / Fax : + 54 114 816 25 22
EGATEL CHILE
EGATEL MEXICO
Avda. Presidente Riesco, 5335 - 9ª Planta
Santiago de Chile
Tlf: +5627143823
Av. Insurgentes Sur 813, Piso 10
Col. Nápoles, México 03810, D.F.
Teléfono: +52 55 5536 7178

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : marta
Create Date                     : 2016:02:10 15:19:43+01:00
Modify Date                     : 2016:02:10 15:20:43+01:00
Subject                         : 
Title                           : 
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2016:02:10 15:20:43+01:00
Creator Tool                    : PDFCreator 1.9.2.0
Format                          : application/pdf
Description                     : 
Creator                         : marta
Document ID                     : uuid:118a55ad-fbb7-4a80-a08e-98295a50883d
Instance ID                     : uuid:3fe7bd31-002c-426e-a658-760282d46c4e
Producer                        : PDFCreator 1.9.2.0
Page Layout                     : TwoPageLeft
Page Count                      : 40
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AGKM820003-02

Navigation menu