EMS Technologies 020MCELL1900 MIRRORCELL II PCS REPEATER User Manual USERS MANUAL

EMS Technologies MIRRORCELL II PCS REPEATER USERS MANUAL

USERS MANUAL

                                           5015 B.U. Bowman Drive  Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598       FCC Part 24E  Transmitter Certification  Test Report  FCC ID:  DNY020MCELL1900  FCC Rule Part: CFR 47 Part 24 Subpart E  ACS Report Number:  06-0347-24E   Manufacturer: EMS Wireless Equipment Type:  PCS Bi-Directional Repeater Tradename: MirrorCell® II Model: CDM1912-743    Manual
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 1   Operator’s Manual        MirrorCell II   Repeater CDM 812, CDM1912 Series               2850 Colonnades Court Norcross, GA 30071  U. S. A. 770.582.0555 Fax 770.729.0075
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 2   Disclaimer  Every attempt has been made to make this material complete, accurate, and up-to-date.  Users are cautioned, however, that EMS Wireless reserves the right to make changes without notice and shall not be responsible for any damages, including consequential, caused by reliance on the material presented, including, but not limited to, typographical, arithmetical, or listing errors.    Copyright Information  © 2001 by EMS Wireless, a division of EMS Technologies, Inc.  EMS Wireless  Norcross, GA  30071 U. S. A.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 3 WARNINGS, CAUTIONS, AND GENERAL NOTES    WARNINGS, CAUTIONS, AND GENERAL NOTES    This product conforms to FCC Part 15, Section 21.  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.    NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  •  Reorient or relocate the receiving antenna.  •  Increase the separation between the equipment and receiver.  •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  •  Consult the dealer or an experienced radio/TV technician for help.   This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful  interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.   Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement.L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.  Installation should be made per ANSI/NFPA 70, the National Electrical Code(NEC), Article  810 specifically for clearances from power and lighting conductors, mounting and grounding.  The screen of the coax cable must be connected to earth(grounded) at the entrance to the building.  This should be done in accordance with applicable National Electrical Code(NEC) installation codes.  In the U.S., this is required by Section 820.93 of the National Electrical Code, ANSI/NFPA 70.  RF Exposure  In accordance with FCC requirements of human exposure to radiofrequency fields, the server and donor radiating elements shall be installed such that a minimum separation distance of 118 cm and 49 cm, respectively, is maintained between the radiating element and the general population.   IC Requirements   The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 4 Safety Considerations   When installing or using this product, observe all safety precautions during handling and operation.  Failure to comply with the following general safety precautions and with specific precautions described elsewhere in this manual violates the safety standards of the design, manufacture, and intended use of this product. EMS Wireless assumes no liability for the customer's failure to comply with these precautions.  WARNING   WARNING Calls attention to a procedure or practice, which, if ignored, may result in damage to the system or system component.  Do not perform any procedure preceded by a WARNING until described conditions are fully understood and met.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 5  If You Need Help  If you need additional copies of this manual, or have questions about system options, or need help with installation and using of the system, please contact the EMS Wireless Customer Support Department.        2850 Colonnades Court Norcross, GA 30071 USA 770.582.0555 ext. 5310 cswireless@ems-t.com
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 6 Service    Do not attempt to modify or service any part of this product other than in accordance with procedures outlined in this Operator's Manual. If the product does not meet its warranted specifications, or if a problem is encountered that requires service, notify EMS Wireless’ Customer Support department.  Service will be rendered according the EMS Wireless’ warranty and repair policy.  The product shall not be returned without contacting EMS Wireless and obtaining a return authorization number from the Customer Service department     When returning a product for service, include the following information: Owner, Model Number, Serial Number, Return Authorization Number (obtained in advance from EMS Wireless Customer Support Department), service required and/or a description of the problem encountered.  Warranty and Repair Policy   The EMS Wireless Quality Plan includes product test and inspection operations to verify the quality and reliability of our products.   EMS Wireless uses every reasonable precaution to ensure that every device meets published electrical, optical, and mechanical specifications prior to shipment.  Customers are asked to advise their incoming inspection, assembly, and test personnel as to the precautions required in handling and testing ESD sensitive opto-electronic components. Physical damage to the external surfaces voids warranty.    These products are covered by the following warranties:   1. General Warranty    EMS Wireless warrants to the original purchaser all standard products sold by EMS Wireless to be free of defects in material and workmanship for the duration of the warranty period of one (1) year from date of shipment from EMS Wireless.  During the warranty period, EMS  Wireless’ obligation is limited to repair or replacement of any product that EMS Wireless proves to be defective.  This warranty does not apply to any product, which has been subject to alteration, abuse, improper installation or application, accident, electrical or
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 7 environmental over-stress, negligence in use, storage, transportation or handling.    2. Specific Product Warranty Instructions    All EMS Wireless products are manufactured to high quality standards and are warranted against defects in workmanship, materials and construction, and to no further extent.  Any claim for repair or replacement of a device found to be defective on incoming inspection by a customer must be made within 30 days of receipt of the shipment, or within 30 days of discovery of a defect within the warranty period.      This warranty is the only warranty made by EMS Wireless and is in lieu of all other warranties, expressed or implied, except as to title, and can be amended only by a written instrument signed by an officer of EMS Wireless.  EMS Wireless Customer Support agents or representatives are not authorized to make commitments on warranty returns.      In the event that it is necessary to return any product against the above warranty, the following procedure shall be followed:      a.  Return authorization shall be received from EMS Wireless Customer Support prior to returning any device.  Advise EMS Wireless Customer Support of the model, serial number, and the discrepancy.  The device shall then be forwarded to EMS Wireless, transportation prepaid.  Devices returned freight collect or without authorization may not be accepted.      b.  Prior to repair, EMS Wireless Customer Support will advise the customer of EMS Wireless test results and will advise the customer of any charges for repair (usually for customer caused problems or out-of-warranty conditions).        If returned devices meet full specifications and do not require repair, or if the customer does not authorize non-warranty repairs, the device may be subject to a standard evaluation charge.  Customer approval for the repair and any associated costs will be the authority to begin the repair at EMS Wireless.  Customer approval is also necessary for any removal of certain parts, such as connectors, which may be necessary for EMS Wireless testing or repair.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 8      c.  Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment.    3. Limitations of Liabilities    EMS Wireless’ liability on any claim of any kind, including negligence, for any loss or damage arising from, connected with, or resulting from the purchase order, contract, or quotation, or from the performance or breach thereof, or from the design, manufacture, sale, delivery, installation, inspection, operation or use of any equipment covered by or furnished under this contract, shall in no case exceed the purchase price of the device which gives rise to the claim.     EXCEPT AS EXPRESSLY PROVIDED HEREIN, EMS WIRELESS MAKES NO WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY GOODS, PARTS AND SERVICES PROVIDED IN CONNECTION WITH THIS AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  EMS WIRELESS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT NOT LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND SERVICE HEREUNDER, OR THE PERFORMANCE, USE OF, OR INABILITY TO USE THE GOODS, PARTS AND SERVICE.    EMS Wireless test reports or data indicating mean-time-to-failure, mean-time-between-failure, or other reliability data are design guides and are not intended to imply that individual products or samples of products will achieve the same results.  These numbers are to be used as management and engineering tools, and are not necessarily indicative of expected field operation.  These numbers assume a mature design, good parts, and no degradation of reliability due to manufacturing procedures and processes.  Handling the CDM 812, CDM1912 Series Repeaters:  1.  Use electrostatic discharge (ESD) precautions when dealing with the modules within the repeater so that units are not damaged.  2.   Opening or removing any module voids the warranty.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 9
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 10 TABLE OF CONTENTS  1.0 Introduction  2.0 Available Options  3.0 Installation Guidelines 3.1  Outdoor Site Selection 3.2  Donor and Server Antenna Selection 3.3  Antenna Mounting and Isolation Measurements 3.4 Repeater Mounting  4.0 Repeater Set-up  5.0 System Optimization  6.0  Detailed Software Commands 6.1  User Names and Passwords 6.2 Basic Commands 6.3 “SET” Commands  7.0 Technical Description 7.1 General Description 7.2 Channelizer Module 7.3  Downlink Power Amplifier 7.4 Power Supply Module 7.5 Duplex Filters 7.6  Status and Control Module 7.7  Automatic Software Driven Gain Control  8.0 Technical Specifications  9.0  Troubleshooting, Maintenance, and Parts Replacement 9.1 Troubleshooting 9.2 Maintenance 9.3 Parts Replacement  Appendix A:  HyperTerminal Configuration  Appendix B: Alarm List
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 11 Appendix C: External Alarms
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 12  LIST OF FIGURES  Figure 1:  MirrorCell II Repeater Exterior View Figure 2:  MirrorCell II Typical Outdoor Repeater System Design Figure 3:  MirrorCel II Indoor Installation Example Figure 4:  Example of Repeater Oscillation Figure 5:  Antenna Isolation Measurement Set-up Figure 6:  Repeater Power Switch Locations Figure 7:  RS232 Port Location Figure 8:  Status Screen Figure 9:  Neighbor List Changes with Repeater Operation Figure 10:  Block Diagram of MirrorCell II Repeater Figure 11:  MirrorCell II Internal Views Figure A-1:  HyperTerminal Connection Description Window Figure A-2:  HyperTerminal Screen for Direct Connection Figure A-3:  HyperTerminal Screen for Modem Connection Figure A-4:  Port Settings for Modem Connection Figure C-1:  External Alarm Connections  LIST OF TABLES Table 1:  Available MirrorCell II Options Table 2:  User Names and Passwords Table 3:  MirrorCell II RF Specifications Table 4:  MirrorCell II Electrical Power Specifications Table 5:  MirrorCell II Mechanical Specifications Table 6:  MirrorCell II Environmental Specifications Table 7:  Troubleshooting Procedures Table B-1:  Alarm Codes
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 13   1.0  Introduction  This fully featured repeater is designed primarily for large outdoor use (several miles radius of coverage, depending on terrain), or for indoor use with medium sized buildings (100,000 to 200,000+ square feet [10,000 to 20,000 square meters]).  The repeater is contained in a weatherproof outdoor NEMA 4 enclosure, as shown in Figure 1.  It may be used as a simple and inexpensive alternative to a base station (BTS).  The block diagram in Figure 2 shows a typical outdoor installation.                                Figure 1:  MirrorCell II Repeater Exterior View
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 14 Additionally, it can be configured with a variety of bandpass filters, so it can be band or channel selective.  For example, the repeater can pass just one channel, a few adjacent channels (i.e. approximately 4.5 MHz for 3 adjacent CDMA channels), or a full 15 MHz PCS band.  This gives the carrier great flexibility to choose exactly which signals are repeated.  For even more flexibility, two separate (non-adjacent) passbands within the same 800 or 1900 MHz band may be specified.  For example, at 1900 MHz, E Band (UL:  1885 - 1890 MHz) and C2 Band (UL:  1895 - 1902.5 MHz) can be repeated using one MirrorCell IITM.  At 800 MHz, one repeater can pass the A and A’’ sub-bands (UL:  824 - 835 MHz), and also pass the A’ sub-band (UL:  845.0 - 846.5 MHz), while rejecting the competitor’s B sub-band (UL:  835 - 845 MHz).   Line of Sight tonearby BTSMirrorCell II RepeaterDonor Antenna,typically parabolicdish, 25 dBi gainServer Antenna,typically base stationpanel design, 17 dBigain @ 1900 MHz-53 dBm+39 dBm (Gain = 92dB)-51 dBm-76 dBm receivedsignal levelCoverage Area7/8" Coax Cable, 2 dBloss @ 1900 MHz+55 dBi ERP(including 1 dB cableloss) Figure 2:  Typical Outdoor MirrorCell II Repeater System Design
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 15 An alternate use of this repeater is for indoor applications.  The MirrorCell II makes great economic sense for buildings that are too large for the EkoMini repeater, but too small to justify a fiber optic DAS (Distributed Antenna System).  One MirrorCell II can cover most typical buildings up to approximately 200,000 square feet using ½” coax and several power dividers feeding approximately eight indoor server antennas.  Figure 3 shows a typical example.  Also, directional couplers with varying levels of coupling values may be used to tailor the power delivered to each building floor for optimal coverage.  The MirrorCell II has these features:   90 – 95 dB gain in a range of models with up to three composite RF output power levels available.  Output power level may be incremented in one dB steps over a 30 dB range, either automatically with built-in software, or manually with software commands.   An optional battery back-up unit is available to maintain repeater operation for several hours during AC power interruptions   Receive diversity is available as an option.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 16 1:4PowerDividerYagi Donor Antenna, 15dBi GainMirrorCell II Repeater  (92 dBGain8-Story Building, eachfloor is 30,000 sq. ft. (175ft. x 175 ft.)1 Server Antenna on eachfloorLine of Sight to nearbyBTS-53 dBm+39.0 dBm-52 dBm-67 dBm received signalstrength+37.0 dBm+27 dBm50 ft. 1/2" coax, 2 dBloss @ 1900 MHz150 ft. 1/2" coax, 6 dB loss+21 dBm at each serverantenna1 dB Cable Loss1:2PowerDivider(3.5 dBloss) 1:4PowerDivider(6.5 dB losseach) Figure 3:  MirrorCell II Indoor Installation Example
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 17 2.0  Available Options  The MirrorCell II repeater is available for all Cellular 800 MHz bands (A, B, A+B, and SMR) and PCS 1900 MHz bands (A – F).  In addition, all available options are shown in Table 1 below:  Single channel or sub-band Two non-adjacent channels or sub-bands  +36 dBm (4 watts) composite RF output power (PCS only) +39 dBm (8 watts) composite RF output power +43 dBm (20 watts) composite RF output power  Wired Telephone Line Interface with Modem for Remote Alarming Wireless (CDMA) Data Modem for Remote Alarming IPWMM Modem  120 - 260 VAC/50-60 Hz Operation 24 VDC Operation  Battery Back-up MPP-100 (External Unit) – non UL Approved Battery Back-up MPP-200 (External Unit) – UL Approved  DIN 7-16(f) Donor/Server Antenna Connectors (Type N(f) is standard)  Receive Diversity, 1900 MHz Units Receive Diversity, 800 MHz Units   Table 1:  Available MirrorCell II Options
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 18  3.0  Installation Guidelines  3.1  Outdoor Site Selection  When the MirrorCell II is used outdoors, site selection is one of the most critical decisions affecting the overall performance of the repeater system. A repeater should be located where it can receive a sufficient line of sight signal from the donor site to maximize the repeater’s performance. For example, supposing a 1900 MHz MirrorCell II has +39 dBm power output specification with a gain of 92 dB.  Then, an input signal level at the donor input connector (after the donor antenna and coax cable) of greater than or equal to –53 dBm (composite power) is required for +39 dBm output:  -53 dBm + 92 dB gain = +39 dBm.  Examples of repeater and accompanying antenna locations include, but are not limited to:    The roof of a building adjacent to the desired coverage area with the antennas mounted to the penthouse or building sides   The top of a hill that is obstructing the donor site’s coverage, with the antennas pipe-mounted at ground level   A water tower with antennas mounted at the top   An existing utility pole, with equipment and antennas mounted below any existing power lines  A newly installed pole or tower  3.2  Donor and Server Antenna Selection  Proper selection of the repeater’s donor and server antennas is crucial in designing the repeater system.  The most important parameter to be concerned with is antenna isolation.  This is a measure of the ability of the donor and server antennas to avoid receiving each other’s signals.  Remember, the repeater is simultaneously transmitting and receiving on each of the uplink and downlink frequency bands.  For this to happen successfully, the two antennas must be well isolated from each other, or excessive signal levels from one antenna will be received by the other antenna.  This sets up a feedback loop, and oscillation begins.  An example of this is shown in Figure 4 below:
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 19 Reflector (Dish) DonorAntennaSectorized Panel ServerAntennaMirrorCell II Repeater,Gain = 90 dBAntenna Isolation + cableloss = 85 dBOscillation occurs becausethe repeater gain is morethan the antenna isolationplus the cable attenuation.  Figure 4:  Example of Repeater Oscillation  Good antenna characteristics, especially front-to-side and front-to-back ratio, help to provide proper isolation between the server and donor antennas.  Proper antenna mounting location is also a key to achieving adequate antenna isolation.    The isolation between antennas must be at least 10 – 15 dB greater than the gain setting of the repeater or the repeater could go into oscillation.  Antenna isolation limits the amount of repeater gain that can be used. Therefore, if the isolation is 90 dB, the repeater gain should be set no higher than 80 dB to ensure proper operation.  Antenna isolation can be approximately estimated with a few calculations.  Please refer to the EMS  Wireless application note “Antenna Isolation Calculations” for details.  Also, a small chart titled “Isolation Examples” shows four example installations using specific antenna models, with the resulting calculated isolation for each.  The donor antenna selection is critical in the design of a properly functioning repeater system because it provides the majority of the required front-to-side ratio.  The donor antenna is typically a high gain antenna, with excellent sidelobe and backlobe suppression.  Microwave dish (reflector) antennas with vertical and horizontal beam widths of less than 15 are ideal candidates for the donor antenna.  This is because the repeater should only re-transmit signal from one base station, generally chosen
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 20 because it has adequate signal strength and enough unused capacity to accommodate the repeater system.  In many urban environments, base stations are physically close together.  The donor antenna must have a narrow beamwidth so it receives and transmits signal to only the desired BTS.  Microwave dish antennas also provide the recommended front-to-back ratio of more than 25 dB to help achieve the required antenna isolation.    Even better donor antenna front-to-side ratio is available with “high performance” or “ultra high performance” reflector antennas.  These models have a metal shroud extending out from the face of the reflector.  The inside of the shroud is covered with microwave absorbing material to suppress side radiation.  The best performance models extend the shroud and use the highest quality absorbing material.  Unfortunately, this increases the wind loading of the antenna and requires a heavier duty support structure.  The trade-off is extremely high front-to-side ratio (frequently 40-55 dB), which allows close physical spacing between the donor and server antenna.  This close physical spacing (sometimes less than 40 feet) is excellent in areas with stringent zoning requirements that limit the structure height.  The server antenna should provide the desired coverage and also provide the recommended front-to-side ratio of 25 dB. Many different types of antennas will work as a server, such as panel antennas, Yagi antennas, and, for indoor applications, omni-directional antennas.  The installer should use these specific ways to achieve proper isolation:    Use high gain, directional antennas with low sidelobes.  This means the front-to-side ratio should be better than 25dB.  Also, use antennas with excellent antenna front to back ratio.   Point the donor and server antennas opposite each other; i.e., at 180 from each other, and ensure that the antennas have minimal backlobe radiation.   Physically separate the antennas, either vertically or horizontally.   Use external shielding, such as wire mesh or a grounded metal plate placed between the antennas.  Reflector antenna manufacturers sell ice shields, normally used to prevent ice from falling on the antennas during winter weather.  They can also be used to enhance isolation because they are metallic fence or mesh material.  The isolation can be frequently improved by about 10 to 20 dB by using an ice shield.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 21 For indoor installations, achieving adequate isolation is still important, but somewhat easier to achieve.  This is because the donor and server antennas are physically separated by the building material, which is normally quite lossy to RF.  This is especially true if the donor antenna is placed on a building roof that has a metallic layer.  In most of these installations, inexpensive yagi donor antennas can be used.  The server antenna(s) are frequently ceiling mount designs with most of the radiation directed down toward the building floor.  This further enhances the isolation.    3.3   Antenna Mounting and Isolation Measurements  Use the following steps to mount the donor antenna.  1.  Mount donor antenna at the initial desired location.  A visual line of sight path to the BTS is critical for a strong, stable donor signal that is a constant level over a long period of time.  2.  Measure the received signal strength from the donor site.  The amount of power the repeater can produce is dependent on this signal level.  3.  If greater signal strength is needed, try raising the donor antenna’s height, or use a higher gain antenna, if possible.  4. Measure the RF channel strength received at the donor antenna and verify that the proper base station sector is being received. The RF channel of the desired base station should be at least 15dB higher than any of the other received RF carriers.  This can be measured using a spectrum analyzer.  If necessary, the donor antenna should be oriented until the desired RF channels are 15dB greater than any others received.  If this cannot be achieved, use an antenna with higher gain.  This means the antenna beamwidth is narrower, which requires greater precision to physically orient the antenna toward the donor site.  But, the donor signal will be higher, and the antenna will be more effective rejecting unwanted signals.  Then, isolation measurements should be made to ensure proper operation of the repeater. Isolation measurement can be accomplished easily by following the procedure outlined below, as illustrated in Figure 5.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 22 Reflector (Dish) DonorAntennaSectorized Panel ServerAntennaSignal Generator,approx. 1 wattoutput (+30 dBm)SpectrumAnalyzer+30 dBm -70 dBmIsolation = +30 dBm - (-70dBm) = 100 dB  Figure 5:  Antenna Isolation Measurement Set-up   1. Mount the server antenna at the initially chosen location to obtain the desired coverage. 2. Inject a known signal within the bandwidth of operation into the server antenna. An unused channel within the band should be used. The signal should be at least 1 watt to allow for an accurate measurement of isolation. If a 1 watt (+30 dBm) test source is not available, the repeater and a low-power signal generator can be used in series to generate a signal of sufficient strength. The repeater will add approximately 60 – 90 dB of gain, depending upon the repeater model, and how much attenuation is added to the repeater. 3. Connect a signal measurement device, such as a spectrum analyzer, to the donor antenna. Measure the received signal level. The RF power difference between the output of the signal generator and the input to the spectrum analyzer is the antenna isolation. (Note that the gain of each antenna is not used in the calculation.)  This test should be done once using downlink frequencies and once using uplink frequencies.  Generally both measurements will be similar, but as much as 10 dB difference can occur.  The final result should be the lower of the two measured values. Antenna isolation should be measured once the donor and server antennas have been mounted at their initially desired location. Isolation measurement is important in properly setting up a repeater.  Although isolation can be approximately calculated, an actual measurement is strongly recommended in most applications.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 23 The repeater gain must be set to at least 10 dB below the measured isolation.  For example, if the measured antenna isolation is 90dB, the repeater gain should be set for no more than 80 dB.   3.4  Repeater Mounting  These recommendations should be followed for best repeater performance:   The repeater should be mounted so the heatsink avoids direct sunlight.  This will help improve the lifetime of the repeater.  The repeater must be mounted upright so that the connectors are on the underside.  This will help prevent a buildup of moisture inside the repeater.  The repeater is equipped with N female (optionally, DIN 7-16) antenna connectors.  Connectors are located at the bottom of the unit.  Ensure that adequate room has been allocated for the bending radius of the cables.  Refer to the cable manufacturer’s specifications for the allowable cable bend radius.  Ensure that adequate room is allowed for the opening and closing of the repeater door.  See the specification table for dimensions of the repeater.  4.0 Repeater Set-up    Refer to the Installation Guide for instructions on mounting and connecting power to the MirrorCell II.    Connect the Donor antenna to the “Donor” port on the MirrorCell II.    Connect the Server antenna to the “Server” port on the MirrorCell II.   DO NOT TURN THE POWER ON UNLESS BOTH DONOR AND SERVER PORTS ARE TERMINATED!  Turn the MirrorCell II on with the power switch located on the inside bottom of the repeater cabinet, shown in Figure 6 below.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 24                    Figure 6a:  Repeater Power Switch Location, A/C Version                   Figure 6b:  Repeater Power Switch Location, DC Version   Power Switch Power Switch
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 25        Connect a laptop computer with a terminal emulator program (i.e., HyperTerminal, ProComm, etc.) to the MirrorCell II RS232 port with a DB9 straight-through serial cable, as shown in Figure 7 below.  The male connector is attached to the repeater port and the female connector is attached to the laptop’s RS232 serial port.                        Figure 7:  RS232 Port Location    Start the terminal program with settings 9600-8-N-1 and initialize the login by pressing ‘enter’.  Details of the terminal program configuration are shown in Appendix A of this Operator’s Manual.  Login to the repeater with your username and password.  The default username and password are “USERNAM1” and “PASSWRD1” respectively, without the quote marks.  Note that all software commands are CASE SENSITIVE.  Section 6 of this Operator’s Manual details Interconnect   Mobile Phone   RS232
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 26 all the software commands available in the repeater.      Type ‘STATUS’ and press ‘enter’ to verify the current repeater settings.  Also, the ‘STATUS’ command can be used after every software parameter is changed to verify the current setup.  The screen should appear similar to Figure 8 below.                       Figure 8:  Status Screen     The UL and DL passband center frequencies are normally preset at the factory.  However, they can be changed by the user, if, for example, the user requires greater attenuation of adjacent out of band frequencies.     To set the peak limit for the unit type ‘SET PEAK #’, where ‘#’ is any number between 18 and the repeater’s maximum rated output power in dBm plus 1.  (Example:  To limit the peak power to +27 dBm, type ‘SET PEAK 28’.)  The default factory setting is the repeater’s maximum rated output power plus 1.  If maximum power is desired, then skip this step.  System Date/Time Repeater Serial and Model Automatic Time Log DL and UL Passband UL RF Gain Offset Relative to DL Gain Peak DL Power Level with all channels driven Alarm Condition DL and UL Attenuation Settings Repeater Internal Temperature
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 27   The automatic setup can be started by typing ‘RESTART’.  The repeater will go through the setup routine to achieve the peak limit output power as set above.  This can take up to a minute to complete and will display a message when it is complete.   A complete list of alarms and their respective alarm code numbers is shown in Appendix B.   The use of external alarms for the MirrorCell II is detailed in Appendix C.     Important Notes:   The MirrorCell II repeater will attempt to set itself to the PEAK limit output power setting using its available gain.  If input (donor) signal is insufficient to reach the output power PEAK setting with the repeater’s available gain, the repeater will remain set using the maximum gain to an output power level of  (INPUT SIGNAL LEVEL) + (REPEATER MAX GAIN) = (OUTPUT POWER LEVEL)    If the repeater is to be moved from its current location to a new location, it is recommended that you manually set the attenuation values to maximum (30 dB) before turning it off.     Ensure that all RF connections remain watertight and mechanically secure.   5.0   System Optimization  The repeater uses highly selective Surface Acoustic Wave (SAW) bandpass filters, which have a group delay of 3 microseconds. Since the propagation delay of free space is 5.4 microseconds per mile, the delay is “equivalent” to somewhat more than ½ mile of free space propagation.   The neighbor lists of the donor base station and the base stations surrounding the area served by the repeater may need to be adjusted after the repeater is installed. For example, in Figure 9, a repeater extends the coverage of BTS1 to a new area.  BTS1 is now a neighbor with BTS4 and BTS5, whereas without the repeater, BTS1 is a
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 28 neighbor with just BTS2 and BTS3. Thus, BTS4 and BTS5 must be added to BTS1’s neighbor list, and BTS1 must be added to BTS4’s and BTS5’s neighbor lists. A drive test of the coverage area should be performed to verify the final setup.                            6.0  Detailed Software Commands  6.1  User Names and Passwords  The repeater login sequence begins by asking for Username and Password. The MirrorCell II allows for four different user names and passwords, each of which has different authorities. The default login parameters are shown in Table 2 below. User Name  Password  Authority USERNAM1 PASSWRD1  read/write USERNAM2 PASSWRD2  read/write USERNAM3 PASSWRD3  read only USERNAM4 PASSWRD4  read only  Table 2:  User Names and Passwords   BTS 1 BTS 3BTS 4COVERAGEAREAREPEATERBTS 2BTS 5 Figure 9:  Neighbor List Changes with Repeater Operation
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 29  Note: The Usernames and Passwords should be changed during installation.   For example, to change a Username and Password:   SET UID# [username]  <enter>  SET PWD# [password] <enter>    6.2  Basic Commands The basic repeater commands are listed below.    STATUS    Displays Status Screen   RESTART    Begin Auto Setup Process   MODEM    Displays Modem Configuration Parameters   GET PASSWORD    Displays a list of User Names and Passwords (USRS 1 and 2)    LOGOUT     Exits or Logs off repeater   EXIT    Exits or Logs off repeater   GET LOG    Displays Log   ALARMS    Displays List of Current alarms and Trigger timestamp   ALARM #    Displays Alarm #’s Parameters (1-20)   LIST ALARMS    Displays a list of all alarms their assigned number and               status   NEED UPDATES  Logs user off terminal and Dial out to MUM to get all settings for the site.  Used when replacing a unit in the field, or repeater parameters has already been setup at the MUM  6.3  “Set” Commands The “Set” Commands allow the user to change specific parameters that define the repeater operation:    SET UL OFFSET    Up Link Gain Offset (0-16)   SET DLPOWER    Desired Down Link Power Setting (17-36)   SET PROTOCOL    System Technology (CDMA, AMPS, GSM)   SET PEAK      Maximum Down Link Output Power (18-42)   SET PWD#      Password for User ID # (8 alpha-numeric)
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 30   SET UID#      User Name for User ID # (8 alpha-numeric)   SET DT       Date in mm/dd/yy format   SET TM       Time in 24hr format hh:mm:ss  SET ID    Unit ID or Name   SET MUMNUMBER   Phone Number to Dial to MUM when Report Active   SET UNTNUMBER    Phone number of the Mirror Cell Unit.   SET REPORT     Report Alarms (ON or OFF)   SET ALARM #      Alarm # active or disabled (ON or OFF)   SET HB PERIOD    Time between Expected Contact 0=HB off (0-999)minutes   SET ALRM RTRY    Number of retries to send alarms. (0-100)   SET ALRM INTV    Minutes between Alarm report retries.    SET DL FREQ # (Freq)  Sets down link center frequency of the band pass   SET UP FREQ # (Freq)  Sets uplink center frequency of the band pass   SET DL ATTN #    Sets down link attenuation to a specified level   SET UL ATTN #    Sets up link attenuation to a specific level    The example below shows how to set the repeater DL and UL passband center frequencies (this example assumes that OPT-2 offering two non-adjacent operating bands has been installed):  Example  >set dl freq 1 1975.00            >set up freq 1 1895.00             >set dl freq 2 1947.50      >set up freq 2 1867.50  Note:  ‘SET UL ATTN #’ and ‘SET DL ATTN’ commands override the auto setup feature and allows the repeater to be set up outside of the RF detected power range of the repeater.  Peak power limit will still function properly at the lowest usable level of detection (+18 dBm typical).  The user may wish to disable down link power detect alarm which will be on constantly due to no RF detected.  The RF detector has typically a dynamic range of detection of 23 dB and factory is calibrated in the factory for a RF power range of +17 to +40 dBm.  The software look up table for the RF detector gives the unit a very accurate means of measuring average RF output power, typically +/-1 dB across the power range.  Greatest accuracy is in the higher power ranges between +30 to +40 dBm.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 31  The following “set” command example illustrate a typical log in session:  Command Examples >set ul offset 2 >set dlpower 34 >set protocol CDMA >set peak 37 >set PWD2 pass2 >set UID2 user2 >set dt 20/02/01 >set dt 02/20/01 >set tm 11:47:00 >set id unit123 >set mumnumber 9876543211 >set untnumber 1234567890 >set report on >set alarm 1 off >set hb period 21 >set alrm rtry 2 >set alrm intv 5    7.0  Technical Description   General Description The block diagram in Figure 10 shows the major components of the MirrorCell II.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 32   Duplexer DuplexerSynthesizerDownlink Power AmplifierDonorAntennaServerAntennaLNADownconvertingMixerDownconvertingMixerUpconvertingMixerUpconvertingMixerSAWBandpassFilterSAWBandpassFilterUplink OutputAmplifierLNADownlinkAmplifierDownlink (Forward) Signal PathUplink (Reverse) Signal PathULDLULDLChannelizer UnitPower SupplyStatus  andControlModulePower Source (120 VAC,200-260 VAC, 24 VDC)   Figure 10:  Block Diagram of MirrorCell II Repeater  The five major modules include:  The Channelizer Module, the downlink power amplifier, power supply, duplexers, and the status and control module (contained within the Channelizer).  Built-in software adjusts and controls the repeater gain and other functions.  An internal view of the repeater with the major components identified is shown in Figure 11.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 33                                             Channelizer Downlink Power Amplifier Duplexers DC Interconnect Module Receive Diversity LNA Full PCS Duplexer Installed
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 34 Figure 11:  MirrorCell II Internal View     The repeater is enclosed in an aluminum case with rear mounted cooling fins.  Aluminum offers a lightweight design with good heat conduction and weatherproof protection.  The housing conforms to the NEMA (weather-proof) standard.  Per the NEMA 4 specification, the enclosure will withstand 65 PSI (pounds per square inch) pressure salt water spray on all four sides with no leakage to the inside.  The unit is cooled with electric fans that are cycled depending on the internal temperature of the unit.  Forced air from the fans is directed between cooling fins on the rear of the cabinet, which enhances the MTBF by as much as 100%.  The transmit and receive antenna ports are standard N-type (DIN 7-16 optional) located on the underside of the repeater.  7.2  Channelizer Module  The primary reference frequency for the MirrorCell II repeater is provided by a 20 MHz temperature stabilized crystal oscillator.  This basic reference frequency is used by the PLL to generate the local oscillator (LO) frequency. The 20 MHz frequency accuracy is 5 ppm. All internally generated frequencies are locked to this basic oscillator. The same LO frequency is used for both the up converter and down converter, ensuring no difference in the input and output frequencies.  The downlink and uplink paths in the channelizer module each consist of an LNA, a down-converting mixer with a low side Local Oscillator that produces a 140 MHz Intermediate Frequency (IF).  Then, SAW (Surface Acoustic Wave) filters, an up-converting mixer, and a post amplifier complete the circuit. The channelizer module also includes power level control functionality.  Note that the uplink path includes the power amplifier in the Channelizer unit, while the downlink path has the power amplifier external to the channelizer.  7.3  Downlink Power Amplifier The downlink power amplifier may have output power levels as shown in Table 1.  The power amplifiers are designed to meet industry standards regarding Adjacent Channel Power Ratio (ACPR) and spectral re-growth.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 35  7.4  Power Supply Module The power supply is designed for an input voltage of 120 VAC, 200-260 VAC, or +24 VDC, depending on the option.  A surge suppression filter is included for voltage transient protection on the A/C powered models.    7.5  Duplexer Filters  The uplink and downlink RF signals are separated and combined with duplexers operating in the appropriate frequency bands. The duplexers are constructed with comb-line cavity bandpass filters, which provide excellent isolation against out-of-band signals.  7.6  Status and Control Module  The status and control module, contained within the channelizer, enables monitoring and control of the repeater. This module determines the status of the Channelizer and identifies failure conditions.  When a failure condition is identified, an alarm is issued.  When this occurs, the module sends a message to a PC over a serial data link (modem). Also, the optional MUM software program, which is installed on a remote computer, can monitor these alarms, and query the repeater on a pre-determined schedule.    7.7   Automatic Software-Driven Gain Control  A key feature of the MirrorCell II repeater is the automatic software-driven gain control, or more simply, Automatic Set-up.  This allows “plug and play” operation with little or no user intervention.  When Automatic Set-up is initialized, built-in software adjusts the internal attenuators in the uplink and downlink signal paths within the Channelizer module.  Note that the UL and DL gains are generally equal to ensure a balanced path, unless the user manually changes them or the uplink signal is too high.  For most applications, the automatic software sequence will set an appropriate gain value without manual intervention.  The following software sequence is used:    The repeater gain and attenuator settings can be reset by using the ‘RESTART’ software command, as described in section 4.  This re-starts the software sequence and initiates Automatic Set-up.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 36   When Automatic Set-up is initiated, variable attenuators are immediately set at their maximum values of 30 dB.  Thus, the UL and DL gain is 30 dB below the specified value.  This prevents the repeater from exceeding its maximum power output specification in non-ideal installation situations.   A power sensor measures the downlink signal level at the server output.  If this level is below the maximum output specification, or ‘PEAK’ level, the software removes UL and DL attenuation in 1 dB steps until one of two things occurs: o  The ‘PEAK’ level is achieved.  In this case, the donor signal is sufficient for the repeater to achieve is ‘PEAK’ setting without using its full gain. o  All the attenuation is removed.  In this case, the donor signal is too low for the repeater to achieve its ‘PEAK’ setting with its available gain.   If the donor signal level increases later (i.e. more channels are added), causing the repeater to exceed its ‘PEAK’ setting, the software will automatically add attenuation to keep the repeater within specification.   If the donor signal level decreases later, the repeater will not remove attenuation to boost the repeater output to its original level.  That is, the software will only add attenuation, but never remove it.  This action differentiates this control system from simple AGC systems.  Normally, a base station and a handset already have a power control system in place.  The repeater gain does not continuously change to maintain its ‘PEAK’ setting, as this would fight and defeat the BTS power control function.    8.0  Technical Specifications  The MirrorCell II specifications are divided into RF (Table 3), Electrical (Table 4) Mechanical (Table 5), and Environmental (Table 6), shown below.  Parameters Uplink Downlink Frequency – Models: 800 MHz: Cellular A (A’’ + A) Cellular B (B + A’ + B’) Cellular AE (A’’ + A + A’ [Excludes B]) Cellular BE (B + B’ [Excludes A’]) Cellular Full Band Public Safety ESMR ESMR Full 1900 MHz:   824 – 835 MHz 835 – 849 MHz 824 – 835 MHz, 845 – 846.5 MHz 835 – 845 MHz, 846.5 – 849 MHz 824 – 849 MHz 821 – 824 MHz 806 – 821 MHz 806 – 824 MHz    869 – 880 MHz 880 – 894 MHz 869 – 880 MHz, 890 – 891.5 MHz 880 - 890 MHz, 891.5 – 894 MHz 869 – 894 MHz 866 – 869 MHz 851 – 866 MHz 851 – 869 MHz
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 37 PCS A PCS B PCS C PCS D PCS E PCS F 1850 – 1865 MHz 1870 – 1885 MHz 1895 – 1910 MHz 1865 – 1870 MHz 1885 – 1890 MHz 1890 – 1895 MHz 1930 – 1945 MHz 1950 – 1965 MHz 1975 – 1990 MHz 1945 – 1950 MHz 1965 – 1970 MHz 1970 – 1975 MHz Bandwidth of Bandpass  800 MHz Models:  200 kHz – 14 MHz 1900 MHz Models:  200 kHz – 15 MHz 800 MHz Models:  200 kHz – 14 MHz 1900 MHz Models:  200 kHz – 15 MHz Composite Output Power Maximum Limit  +23dBm +/- 1 dB (200 mW)   +33 dBm +/- 1 dB (2W) +36 dBm +/- 1 dB (4W) (1900 MHz only) +39 dBm + 0.5/-1.0 dB (8W) +43 dBm + 0.5/-1.0 dB (20W) Gain at Minimum Attenuation: 800 MHz:  1900 MHz: +36 dBm (4W) option +38.5 dBm (7W) option +43 dBm (20W) option (see next page) 90 dB Nominal for any power output option  90 dB Nominal 92 dB Nominal 95 dB Nominal (see next page) 90 dB Nominal for any power output option  90 dB Nominal 92 dB Nominal 95 dB Nominal Gain Range  30 dB  30 dB Gain Flatness  2.5 dB pk to pk  2.5 dB pk to pk Gain Change over temperature  +/- 2 dB  +/- 2 dB Gain Step Size  1 +/- 0.5 dB  1 +/- 0.5 dB Gain change over BW  +/- 2 dB  +/- 2 dB Number of Carriers  Single or Multiple  Single or Multiple Noise Figure at Maximum Gain 800 MHz: 1900 MHz:  <5 dB <5 dB  <6.5 dB <6.5 dB Spurious Output  FCC/IC  FCC/IC Number of Bandpasses or Channels  1 or 2, depending on option  1 or 2, depending on option Signal Electrical Delay  3 sec (Typical)  3  sec (Typical) Connectors  N(f) Standard, DIN 7-16 Optional  N(f) Standard, DIN 7-16 Optional Mean Time Between Failures (MBTF)  75,000 hours  75,000 hours  Table 3:  MirrorCell II RF Specifications
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 38 RF Output Power  Current and Power Requirement  120 VAC Power Option  220 VAC Power Option  24 VDC Power Option +36 dBm (4W) (1900 MHz only)  3.0 amps  1.6 amps  10.5 amps +39.0 dBm (8W) 800 and 1900 MHz  3.0 amps  1.6 amps  10.5 amps +43 dBm (20W) 800 and 1900 MHz  4.0 amps  2.2 amps  14.5 amps  Table 4:  MirrorCell II Electrical Power Specifications   Parameter Specification Housing, (WxHxD)  15 x 24 x 14 inches (38.1 cm x 61 cm x 35.6 cm) Weight  49 pounds (22.3 kg) Housing Material  Aluminum, off-white paint color Cooling Convection/Forced Air  Table 5:  MirrorCell II Mechanical Specifications
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 39  Parameter Specification Operating Temperature  -25 to 50 C.  Storage Temperature  -40 to 75 C Enclosure NEMA 4 (Weatherproof)  Table 6:  MirrorCell II Environmental Specifications   9.0  Troubleshooting, Maintenance and Parts Replacement 9.1  Troubleshooting:  A chart of troubleshooting procedures is shown in Table 7 below.  PROBLEM  POSSIBLE CAUSE  SOLUTION LED  Power Supply Module is not lit  1.  Unit not turned on 2.  No power to unit 3. Module failure 4.  Input AC or DC wiring is faulty. 1.  Plug in/turn on unit 2.  Restore power to unit 3. Replace module 4.  Rewire/repair power source to repeater. LED on power supply module is lit but cannot login to the repeater 1.  Software emulation program is not set properly 2.  Software emulation program is not working properly 3. Cables not functioning properly 4. Bad Channelizer 1.  Verify program is set properly 2.  Verify program is working properly; replace if necessary 3. Replace cable 4.  Replace Channelizer module Poor reverse signal quality; forward signal quality looks fine Excessive noise contribution to BTS because gain set too high  Reduce repeater gain setting Output power too low on forward link  1.  Receiving too low of a signal from donor site 2.  Gain not set correctly 1.  Verify adequate signal is received; adjust donor antenna if necessary 2. Reset gain Receiving sufficient signal strength but too much interference to make a call Repeater goes into oscillation because of insufficient antenna isolation 1.  Improve antenna isolation:    Further separate antennas    Mount a shield between antennas 2.  Reduce repeater gain
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 40 Table 7:  Troubleshooting Procedures  9.2  Maintenance  The MirrorCell II does not require preventative maintenance.  9.3   Parts Replacement  In case of repeater failure, EMS Wireless recommends you send back the entire repeater for repair, and mount a spare repeater in its place.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 41  Appendix A:  HyperTerminal Configuration   HyperTerminal may be used for terminal emulation when using remote control of the repeater. Use the following steps for setting up HyperTerminal.  1. In the Start menu, open the Programs folder. Go to the Accessories folder in the Programs folder. 2.  Choose Hyper-terminal. In that folder, choose HyperTerminal. 3. A dialog box will ask you to name the session. Use any name you choose. Select the icon showing the two telephones. See Figure A-1.  Figure A-1:  HyperTerminal Connection Description Window   4. For a direct connection to the repeater, choose “Direct to Com X” in the drop down box. See Figure A-2.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 42   Figure A-2:  HyperTerminal Screen for Direct Connection  5.  For remote connection via modem, enter the number you wish to dial and choose to connect using “Standard Modem” as in Figure A-3.   Figure A-3. HyperTerminal Screen for Modem Connection
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 43 6.  After clicking OK, you will need to choose “Port Settings.” Select:   Bits per Second: 9600   Data bits: 8  Parity: None   Stop bits: 1  The port settings will be the same for direct connection and remote connection. For a direct connection to the repeater, make sure flow control is set to “None”.   See Figure A-4 below.    Figure A-4:  Port Settings for Modem Connection    The MirrorCell II  will auto answer on the 2nd ring. Once the modems handshake and a session is started it may be necessary to press the <enter> key to initiate login sequence.
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 44  Appendix B:  Alarm Table   A complete list of alarms is shown in Table B-1 below.    Table B-1:  Repeater Alarms  Alarm Number  Alarm Name  Alarm Status 1 SynthLock Uplink on 2 SynthLock DownLink on 3 OverTemp on 4 Fan Alarm on 5 AmpDownLink on 6 AmpUplink on 7  Low Output Pwr DL  on 8 Power AC on 9 Batt Power DC off 10  Low V DC Input  on 11 OverDrive Uplink on 12  Com Alarm, Heartbeat  off 13 External 1 on 14 External 2 on 15 External 3 on 16 External 4 on 17 Intrusion on 18  S Param Change  off 19 Invalid Logins on 20 OverDrive DL on
EMS Wireless Operator’s Manual MirrorCell II CDM 812, CDM1912 Series 608112-1, Rev C 45  Appendix C:  External Alarms  Other pieces of equipment can be alarmed by connecting relay outputs into the external alarms of the MirrorCell II. An alarm condition will be generated when the open collector input is pulled to common ground. The input has a very weak pullup resister in circuit.  The external alarm inputs can be physically connected either on the alarm terminal-strip as pictured in figure C-1 or directly to the DC Distribution board on the labeled jumper. The software should be configured to not alarm any external alarm not physically connected to the repeater. The software alarms for the external alarms are in order and number 13 to 16. Alarm 9 corresponds to the Batt Backup alarm input and is used to alarm BBU systems attached to the repeater.                    Figure C-1

Navigation menu