ERG Transit Systems MCR500 PC TYPE CARD READER User Manual users manual
ERG Transit Systems PC TYPE CARD READER users manual
Contents
- 1. USER MANUAL
- 2. users manual
users manual
FCC ID: Q47-MCR500 EMC Technologies Report No. T50307_A APPENDIX G USER MANUAL EMC Technologies Pty Ltd Unit 3/87 Station Road, Seven Hills, NSW 2147 Australia +612 9624 2777 +612 9838 4050 www.emctech.com.au Page 1 of 13 Device Product Group MCR500 User Manual Document No: DPG-00266 ERG Approvals Name: Author Dan Zorde Category: 81 Manager Stefan Walter Revision: Group Manager Gino Bertino Signature: Date: This material is confidential to ERG and may not be disclosed in whole or in part to any third party nor used in any manner whatsoever other than for the purposes expressly consented to by ERG in writing. This material is also copyright and may not be reproduced, stored in a retrieval system or transmitted in any form or by any means in whole or in part without the express written consent of ERG. Device Product Group Security Level 3 MCR500 User Manual Document History Revision Revision Date Description Author 0.1 12 Jan 2004 Initial Draft M Hanssen 1.0 8 Mar 2004 Released M Hanssen 1.1 28 Feb 2005 Updated with details of short variant MCR500 Dan Zorde 2.0 4 Mar 2005 Released for FCC Dan Zorde DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 2 of 12 Device Product Group Security Level 3 MCR500 User Manual Table of Contents INTRODUCTION .................................................................................................................................. 6 1.1 1.2 1.3 PURPOSE........................................................................................................................................ 6 SCOPE............................................................................................................................................ 6 TERMINOLOGY ................................................................................................................................ 6 MCR500 TECHNICAL SPECIFICATIONS........................................................................................... 7 ELECTRICAL SPECIFICATION .......................................................................................................... 8 3.1 HOST PCMCIA INTERFACE ............................................................................................................. 8 3.2 POWER SUPPLY .............................................................................................................................. 8 3.3 RF CONTROLLER............................................................................................................................. 8 3.3.1 Transmitter ............................................................................................................................ 8 3.3.2 Receiver ................................................................................................................................ 8 RECOMMENDED HARDWARE .......................................................................................................... 9 SOFTWARE AND IPAQ CONFIGURATION ..................................................................................... 10 5.1 5.2 TEST SOFTWARE........................................................................................................................... 10 IPAQ SOFTWARE INSTALLATION .................................................................................................... 10 MCR500 .............................................................................................................................................. 11 6.1 6.2 MCR500 PHOTO’S ....................................................................................................................... 11 MCR500 SHORT VARIANT PHOTO’S .............................................................................................. 12 DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 3 of 12 Device Product Group Security Level 3 MCR500 User Manual List of Tables TABLE 1: RECOMMENDED HARDWARE.............................................................................................................. 9 List of Figures FIGURE 1: TERMINOLOGY ................................................................................................................................ 6 FIGURE 2: IPAQ WITH MCR500 AND MCR500 SHORT VARIANT PHOTOS ......................................................... 9 FIGURE 3: SOFTWARE ................................................................................................................................... 10 FIGURE 4: MCR500 PHOTO OF THE FRONT ................................................................................................... 11 FIGURE 5: MCR500 PHOTO OF THE BACK ..................................................................................................... 11 FIGURE 6: MCR500 SHORT VARIANT PHOTO OF THE FRONT .......................................................................... 12 FIGURE 7: MCR500 SHORT VARIANT PHOTO OF THE BACK ............................................................................ 12 DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 4 of 12 Device Product Group Security Level 3 MCR500 User Manual FCC Compliance Statement This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encourage to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Warning: Any changes or modifications not expressively approved by ERG Transit Systems could void the user's authority to operate this equipment DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 5 of 12 Device Product Group Security Level 3 Introduction 1.1 Purpose MCR500 User Manual The purpose of this document is to provide summary technical details of the electrical interface and physical characteristic of the Multiprotocol Card Reader (MCR500) and its shorter variant. It is intended for use by third party developers wanting to integrate the MCR500 Module into new or existing products. 1.2 Scope This manual is intended for use by third party developers and integrators familiar with similar type of equipment. This manual contains technical information sufficient to give technical personnel an operational understanding of the MCR500 and its variant. 1.3 Terminology Figure 1: Terminology Term Definition Amp(s), Ampere(s) ASK Amplitude Shift Keying bps Bits per second BPSK Binary Phased Shift Keying CMOS Complementary Metal-Oxide Semiconductor CSC Contact-less Smart Card DUT Device Under Test EEPROM Electrically Eraseable ROM EMC Electromagnetic Compatibility EPLD Eraseable, Programmable Logic Device GND Ground – negative supply Host A processing unit. (iPaq) Hz Hertz, cycles per second IEC International Electrotechnical Commission ISO International Standards Organisation JTAG Joint Test Action Group MCR Multi protocol Contactless Reader mm millimetre(s) NRZ-L Non-return to zero - level OOK On-Off keying PCB Printed Circuit Board RAM Random Access Memory second(s) SAM Security Access Module DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 6 of 12 Device Product Group Security Level 3 MCR500 User Manual MCR500 Technical Specifications Form Factor • PCMCIA Type II PC Card Extended. • Card and Socket Services 2.1 compliant Contactless Card • Contact less cards as per ISO 14443 type A & type B • 8bit Parallel access to controller. Security Access Modules • 2 x ID-000 SAM sockets provided. • 8Bit Parallel access to controller. Power Consumption • <500mA worst case. (Datasheet Calculations, 5V SAMs) • <160mA @ 3.3V (Card transaction with 2 SAMs) • <50mA when in standby mode (Both chips in standby mode). • <15mA when in sleep mode Temperature Range • Operating temperature range 0º to +70ºC. • Storage temperature range -20º to +80ºC. Weight & Dimmensions • 40g • 121.6 x 53.9 x 5.0mm (± 0.3) Humidity • 5% to 95% Relative Humidity (non- condensing). Ingress Protection • IP52. EMC Compliance • US – FCC Part 15 • Europe - CE R&TTE • Australia C Tick Operating System • Windows CE 2003 (Driver available) • Extendable to other PC operating systems. DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 7 of 12 Device Product Group Security Level 3 Electrical specification 3.1 Host PCMCIA interface MCR500 User Manual Item Description MCR to Host communication interface 3.2 PCMCIA Type II PC Card Extended. Card and Socket Services 2.1 compliant Power Supply The MCR500 PC Card module derives power directly from the host. Item 3.3 Description Supply voltage 3.3Vdc ±0.1V with ripple of less than 100mV peak-peak. Supply current Maximum 500 mA, typical 150 mA Input power requirements Maximum 1.65 Watts, typical 0.5 Watts RF controller The standards supported by the RF controller are ISO/IEC 14443 Type A, ISO/IEC 14443 Type B and Mifare Standard. 3.3.1 Transmitter The MCR500 transmitter complies with the following specifications: Item Description Carrier Frequency 13.56 MHz + 7 kHz (ISO/IEC 14443-2:2001, 6.1) Modulation Rise and Fall Time < 2.0 µsec (ISO/IEC 14443-2:2001, 8.1.2 and 9.1.2) ASK Modulation 100% Modified Miller (ISO/IEC 14443-2:2001, 7 and 8) 8%-14% NRZ (ISO/IEC 14443-2:2001, 7 and 9) 3.3.2 Receiver The MCR500 receiver complies with the following specifications: Item Description Carrier Frequency 13.56 MHz Subcarrier Frequency 847.5 kHz (ISO/IEC 14443-2:2001, 7, 8 and 9) Subcarrier Data OOK Manchester (ISO/IEC 14443-3:2001 7 and 8) BPSK NRZ-L (ISO/IEC 14443-2:2001, 7 and 9) DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 8 of 12 Device Product Group Security Level 3 MCR500 User Manual Recommended Hardware Figure 2: iPAQ with MCR500 and MCR500 Short Variant Photos Ref 1. Item / Order No Description IPAQ Pocket PC FA107A H5550 249704-B22 Source / Manufacturer Purpose Hewlett-Packard Processing Unit, Interface for transactions Hewlett-Packard FA120A#AC3 PC Card Expansion Pack PC Slot for IPAQ, external battery 3. MCR500 / 11081 Multipurpose Card Reader ERG Card reader 4. MCR500 / 18252 Multipurpose Card Reader ERG Card reader with shorter antenna 2. H5550/ Qty Table 1: Recommended Hardware DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 9 of 12 Device Product Group Security Level 3 MCR500 User Manual Software and iPAQ Configuration The following describes how the iPAQ software should be configured for correct operation. This assumes that an application based on ERG example source files has been created called MCR500APP.EXE. 5.1 Test Software Ref Description Ver Source Purpose 1. MCR500.DLL 1.0.0.6 ERG MCR500 PCMCIA Driver 2. MCR500APP.EXE 1.0 ERG MCR500 Application Software 3. MFCCE300D.DLL 6.0.99.0 MS MFC DLL 4. CIS.BIN 00.15 ERG MCR500 EEPROM Code (CIS) Figure 3: Software 5.2 iPAQ Software installation Install Microsoft ActiveSync on the PC following the instructions which came with the iPAQ. After successful installation place the iPAQ into its cradle and wait for ActiveSync to connect. Then launch the ActiveSync Explorer from the PC’s System Tray and copy the following files from the DAMS release floppy onto the iPAQ: A:\mcr500.dll to \Windows A:\ mfcce300d.dll to \Windows A:\mcr500app.exe to \Windows\Start Menu A:\cis.bin to \ Enable mcr500app in the Start Menu by selecting the appropriate entry in: Start|Settings|Menus DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 10 of 12 Device Product Group Security Level 3 MCR500 6.1 MCR500 Photo’s MCR500 User Manual Figure 4: MCR500 Photo of the Front Figure 5: MCR500 Photo of the Back DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 11 of 12 Device Product Group 6.2 Security Level 3 MCR500 User Manual MCR500 Short Variant Photo’s Figure 6: MCR500 Short Variant Photo of the Front Figure 7: MCR500 Short Variant Photo of the Back DPG-00266 Revision 2 / 4 Mar 2005 ERG Confidential © ERG 2005 Page 12 of 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:05:11 07:21:45Z Modify Date : 2005:05:11 17:22:19+10:00 Page Count : 13 Creation Date : 2005:05:11 07:21:45Z Mod Date : 2005:05:11 17:22:19+10:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : Les Dickenson Metadata Date : 2005:05:11 17:22:19+10:00 Creator : Les Dickenson Title : Microsoft Word - APPENDIX G ATTACHEMENT _Report A_.docEXIF Metadata provided by EXIF.tools