EU3C SCND502E1234 PART 15 CLASS B COMPUTING PERIPHERAL User Manual

EU3C COMPANY LIMITED PART 15 CLASS B COMPUTING PERIPHERAL Users Manual

Users Manual

Download: EU3C SCND502E1234 PART 15 CLASS B COMPUTING PERIPHERAL User Manual
Mirror Download [FCC.gov]EU3C SCND502E1234 PART 15 CLASS B COMPUTING PERIPHERAL User Manual
Document ID1436408
Application IDHFIHB9JEbgnupxAEme8CLA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize337.64kB (4220449 bits)
Date Submitted2011-03-23 00:00:00
Date Available2011-03-23 00:00:00
Creation Date2011-03-04 18:52:44
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2011-03-17 15:03:49
Document TitleMicrosoft Word - Generic FS-I5MB User manual_110302
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

FilmScan35 I
User Manual
I.
Unpack FilmScan35 I
FilmScan35 I
CD‐ROM
Negative Film Holder
Quick Installation Guide
Slide Film Holder
USB cable
Clean brush
NOTE




This film scanner supports Windows XP ,Vista/Windows 7 (32/64bits) via USB
2.0 only.
We strongly suggest using a clean, dry, non‐alcohol cotton swab to insert into
the film scanner slot and clean the glass surface periodically to produce a
clear image.
Make Sure all negative films, slide films and cover trays are free of dust and
dirt before inserting into the filmscan35 I as this may affect the image quality
when scanning.
When cleaning films, please use a professional recommended purger from a
photo store to avoid damaging old or precious films.
-1-
II.
Install film into the film holder
Install the slide into holder:
1.
2.
Open the slide holder as illustrated
Put slide into positive slide slot
3. Close the film holder
-2-
Install the negative film into holder:
1.
2.
Open the film holder as illustrated
Install film into negative film slot
3.
-3-
Close the film holder
NOTE
 To avoid mirror image, follow the serial numbers (from left to right) on top of
film when install negative film into holder.
Figure 1

If the image is upside down [see fig. 2] , the image can be corrected by
continuously “Rotate” function in Image Scan Tool after capture[see fig. 3].
Figure 2
-4-
Figure 3
III. Installation
To use FilmScan35 I, please complete
the following installation in advance.
1. Turn on the computer.
2. Insert the installation CD into the
CD-ROM drive and the installation CD
menu will appear.
3. Choose Installation.
-5-
4. Follow the on-screen instructions. (XP,Vista/Windows 7)
-6-
-7-
-8-
5. After completing software installation, please connect FilmScan35 I to PC.
New Hardware Wizard will detect a new device if your OS is Vista .
6.Select “Locate and install driver software(recommended)” in Vista
-9-
OS.
The
7.After completing the installation, the filmscanner is ready to start with “Image Scan
Tool” under program files. (XP,Vista/Windows 7) restart is not required, but it is
recommemded to restart your PC after installation/un-installation.
IV. Use FilmScan35 I
Copy button
Power staus LED
USB Cable
Film Slot
-10-
Start to use FilmScan35 I
1.
Put Film into film slot
2.
Insert the slot into FilmScan35 I
-11-
3.
Connect FilmScan35 I to PC:
4.
Click “Image Scan Tool” to enter operation interface as below
-12-
5.
Press “Copy” button to capture the image
6.
Process necessary modification by function buttons in right hand side
-13-
7.
Save captured images to PC
8.
Get final images from PC for further review and edit
-14-
User interface introduction
When user selected a “Negative” source, the image in “Live View” window will be exactly like
the processed result.
-15-
If device applies a slide, “Live View Type” will still show color image and the Film Type will
remain the same.
This is the live view under black and white negative option.
-16-
User can convert images from traditional film to digital either by “Snap Shot”
button in Image Scan Tool or the button on top of filmscanner. Then, the
capture result will appear in the “Snap Shot” and “Final images to save” windozw.
All of the effect in Image Scan Tool will be ready for instant preview in “Snap Shot” and “Final
images to save” window.
-17-
Apply the Mirror function by pressing the “Mirror” icon, that will flip the
image and be shown in the “Snap Shot” window as well as the “Final images to save”.
Or apply the Rotate function by pressing “Rotate” button, the image will be rotated 90
degrees each time. Images can be continuously rotated a full 360 degrees or until desired.
-18-
If user wishes to delete a specific image from captured pool, simply click the image under
“Final image to save” again, then the selected image can be deleted directly by applying the
“Delete” button.
After modification, user can save the images to default location at “C:\Documents and
Settings\Users\My Docuemtns\My Pictures”.
-19-
Or define preferable location for saving captures images by pressing directory button.
Another window will pop out for user to select required location.
Once press “Save” key, all of captures images will be saved into defined location.
image” saving window shall be empty after press the “Save” button.
-20-
The “final
When completed the capture, user can press “Exit” button to quit this Image Scan Tool.
Then, review captured images or process more fancy modification with bundle software for
PC.
-21-
V.
Specification
Image Sensor:
5 mega CMOS sensor
Lens:
F no.= 2.0, 4 Glass elements,
Focus Range:
Fixed focus
Exposure Control:
Automatic
Color Balance:
Automatic
Scan Quality
1,800 dpi /3,600 dpi(SW interpolation)
Data Conversion
10 bits per color channel
Scan Method
Single pass
Light Source
Back light (3 white LEDs)
Interface:
USB 2.0
Power:
USB port
Dimensions
90.45x100.6x150.3mm
Weight
0.392kg
Operating Systems
Windows XP/ Vista/Windows 7
-22-
VI. Clean dust from film scanner
Please remove the film folder from device when you found any dust on live view window.
Then you can use the clean brush to wipe the dust.
NOTE
 We strongly suggest using a clean, dry, non‐alcohol cotton swab to clean the glass surface
periodically to produce a clear image during operation.
-23-
NOTE
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY
UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID
THE USER AUTHORITY TO OPERATE THE EQUIPMENT.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
‐ Reorient or relocate the receiving antenna.
‐ Increase the separation between the equipment and receiver.
‐ Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
‐ Consult the dealer or an experienced radio/TV technician for help.
‐ Modifications not expressly approved by the manufacturer could void the user's authority
to operate the equipment under FCC rules.
-24-

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Administrator
Create Date                     : 2011:03:04 18:52:44+08:00
Modify Date                     : 2011:03:17 15:03:49+08:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2011:03:17 15:03:49+08:00
Format                          : application/pdf
Title                           : Microsoft Word - Generic FS-I5MB  User manual_110302
Creator                         : Administrator
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:369d70f7-d585-46c7-a327-36382e48cc95
Instance ID                     : uuid:21f82a69-6eb4-48f4-9152-ea2274dcc612
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WFZSCND502E1234

Navigation menu