RFM-CSB-3
The RFM-CSB-3 module
The RFM-CSB-3 is a class 2 Bluetooth 4.0
module for integration into lighting fixtures,
LED drivers or other lighting controls. The
module contains a powerful 32 bit ARM®
CortexTM microcontroller and 2.4GHz
transceiver with on-board antenna. Four logic
level control signals are available on the 6-pin
card edge connector. The module operates
exclusively through the Casambi app (free on
IOS and Android).
The BLE mesh Network
Features of the Module include:
•
•
•
•
•
Wireless Bluetooth 4.0 Mesh Network
The Bluetooth 4.0 mesh network operates
without the need for additional controllers
or gateway units. The 200ft (60m) open air
functioning distance enables a wide range
of lighting arrangements while the exclusive
Casambi-Bluetooth connection prevents the
lighting system from interfering with other
Bluetooth networks.
Free Casambi lighting control app
Four programmable control lines
Easy integration with card-edge SMT
connector interface
FCC & CE certified
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
TABLE OF CONTENTS
Operation
Block Diagram
Peripheral Blocks
Zero Cross Detection
Specifications
Dimensions
10
Regulatory Statements
11
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
OPERATION
1.
The RFM-CSB-3 is an embedded wireless module intended to operate in conjunction with
the Casambi Lighting control app. Four configurable I/O lines interface to the host device for
control of up to 4 independent lighting channels.
A highly integrate SOC (system on chip) contains a 32 bit ARM® CortexTM microcontroller, 2.4GHz transceiver and several peripheral blocks. These blocks include PWM, SPI, I2C,
UART and GPIO (i.e. pushbutton, relay control). These can be configured in Casambi Admin
webpages and taken into use without a need to re-program the module.
The default factory configuration for the I/O is four PWM outputs @ 1.2kHz
2.
BLOCK DIAGRAM
SOC
IO (P0.04-PO.10)
GPIO
RAM
SWCLK
SW-DP
SWIO
x1
32MHZ
x2
AHB Multi-Layer
CLOCK
TIMER
XTAL
CPU
UART
Chip Antenna
ARM CORTEX
M4
SPI
ADC
ANT1
RADIO
VCC (3.0-3.3V)
ANT2
BALUN
POWER
DC/DC
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
3. PERIPHERAL BLOCKS
a. PWM
Any GPIO pin can be configured to output a PWM signal. Up to 4 PWM channels can be used
simultaneously. PWM frequency can be determined freely up to 40 kHz. By default the PWM
frequency is the same for all PWM channels. The maximum resolution is 400-1600 steps and
it depends on the PWM frequency. The PWM signal is logic level (max. VCC) and it has driving
capacity from 0,5 mA (standard) up to 15 mA (high-drive).
b. SPI
RFM-CSB-3 supports a 3-wire (SCK, MISO, MOSI) bidirectional SPI bus with fast data
transfers to and from multiple slaves. RFM-CSB-2 acts as a master and it provides a simple
CPU interface which includes a TXD register for sending data and an RXD register for
receiving data. These registers are double buffered to enable some degree of uninterrupted
data flow in and out of the SPI master.
Each of the slave devices requires an individual chip select signal which can be connected to
any available GPIO pin. The SPI master does not implement support for chip select directly.
Therefore the correct slave must be selected independently of the SPI master.
The GPIOs used for each SPI interface line can be chosen from any GPIO on the module and
are independently configurable. This enables great flexibility in module pinout and enables
efficient use of printed circuit board space and signal routing.
The SPI peripheral supports SPI modes 0, 1, 2, and 3.
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
c. I2C
This two-wire interface uses clock (SCL) and bidirectional data (SDA). The protocol makes it
possible to interconnect up to 128 individually addressable devices. The interface is capable
of clock stretching and data rates of 100 kbps and 400 kbps are supported.
The GPIOs used for each Two-Wire Interface line can be chosen from any GPIO on the module
and are independently configurable.
d. UART
The Universal Asynchronous Receiver/Transmitter offers fast, full-duplex, asynchronous serial
communication with built-in flow control (CTS, RTS) support in HW up to 1 Mbps baud. Parity
checking and generation for the 9th data bit are supported.
The GPIOs used for each UART interface line can be chosen from any GPIO on the module and
are independently configurable.
e. GPIO
Each of the four I/O can also be configured for alternate input/output functions. Casambi
supported functions include:
• Pushbutton input • Relay control output • Zero Detect Input • Fixed “idle” state output
The I/O can be further tailored using options such as:
• Input/output polarity • Output drive strength • Internal pull-up and pull-down resistors
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
4.
ZERO CROSS DETECTION (ZD)
The RFM-CSB-3 can be configured to detect the zero crossing point of an AC signal. This is
necessary to take advantage of Casambi’s “Smart Switching” feature. This looks for a pattern
of on-off cycles (quickly switching AC source on & off) in order to implement specific modes or
settings.
For proper Smart Switch operation, local VCC of the module must be kept alive during loss of
AC for 1.5 seconds. A 1200uf cap on VCC is typically recommended.
It is the responsibility of the host system designer to create the zero detection circuit and it’s
output needs to be compatible with logic level inputs of the RFM- CSB-1 (see specifications
section). ZD polarity and phase are adjustable in the Casambi admin webpages.
If Smart switching is not required, it is suggested to configure the ZD input for online/
offline detection. This allows the module to notify the network when it goes offline. This
reduces network bandwidth as it will not be repeatedly polling for a device that is no longer
responding. Local VCC must be kept alive for at least 500ms to support this feature.
ZERO DETECT CHARACTERISTICS
MIN
T YPICAL
ZERO DETECT FREQUENCY, FMAINS
MAX
60
UNITS
Hz
ZERO DETECT HIGH TIME, TZD_H
20
ms
ZERO DETECT LOW TIME, TZD_L
20
ms
1/f MAINS
Zero Detect
tZD_H
tZD_L
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
5.
SPECIFICATIONS
MAXIMUM RATINGS
MIN
MAX
UNITS
SUPPLY VOLTAGE, Vcc
-0.3
+3.6
I/O PIN VOLTAGE
-0.3
Vcc + 0.3
STORAGE TEMPERATURE
-40
+125
°C
OPERATING TEMPERATURE
-25
+70
°C
POWER SUPPLY SPECIFICATIONS
MIN
T YPICAL
MAX
UNITS
+2.5
+3.0
+3.3
TX/RX ACTIVE
15
21
mA
IDLE
1.5
mA
T YPICAL
MAX
UNITS
2483
MHz
SUPPLY VOLTAGE, Vcc
SUPPLY CURRENT, Icc
RADIO SPECIFICATIONS
MIN
OPERATING FREQUENCIES,
fop, 1MHZ Channel Spacing
2400
PLL PROGRAMMING RESOLUTION,
PLLres
FREQUENCY DEVIATION,
fBLE
ON-AIR DATA RATE, bpsFSK
±225
250
MAXIMUM OUTPUT POWER, PRF
SENSITIVITY, PSENS
±250
MHz
±275
kHz
2000
kbps
dBm
-89
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
-93
dBm
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
GPIO SPECIFICATIONS
MAX
UNITS
0.7 Vcc
Vcc
0.3Vcc
OUTPUT HIGH VOLTAGE, VOH
Vcc-0.3
Vcc
OUTPUT LOW VOLTAGE, VOL
0.3Vcc
INPUT HIGH VOLTAGE, VLH
INPUT LOW VOLTAGE, VIL
MIN
T YPICAL
SOURCE CURRENT, IGPIO_IN
14
mA
SINK CURRENT, IGPIO_OUT
15
mA
PULL-UP RESISTANCE, RPU
11
13
16
kΩ
PULL DOWN RESISTANCE, RPU
11
13
16
kΩ
*Total source/ sink current of all GPIO pins combined is 15mA. If required source/ sink current for any GPIO pin
exceeds 0.5mA, that GPIO pin must be configured for high-drive.
PWM SPECIFICATIONS
MIN
T YPICAL
MAX
UNITS
40
kHz
PWM RESOLUTION @ fPWM 10kHZ
1600
steps
PWM RESOLUTION @ fPWM 20kHZ
800
steps
PWM RESOLUTION @ fPWM 40kHZ
400
steps
PWM FREQUENCY, fPWM
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
SPI TIMING PARAMETERS
MIN
T YPICAL
MAX
UNITS
MBPS
BIT RATES FOR SPI, fSPI
0.125
DATA TO SCK SETUP, tDC
10
ns
SCK TO DATA HOLD, tDH
10
ns
SCK TO DATA VALID, tCD
60
SCK HIGH TIME, tCH
40
ns
SCK LOW TIME, tCL
40
ns
SCK FREQUENCY, fSCK
0.125
80
SCK RISE AND FALL TIME, tR, tF
tCH
ns
MHZ
100
ns
tCL
SCK
tDC
tDH
MISO
tCD
MOSI
SPI Timing Diagram, One Byte Transmission, SPI Mode 0
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
UART SPECIFICATIONS
MIN
T YPICAL
MAX
UNITS
RUN CURRENT @ MAX BAUD RATE
230
uA
RUN CURRENT @ 115200 bps
220
uA
RUN CURRENT @ 1200 bps
210
uA
BAUD RATE FOR UART
1.2
I2C TIMING PARAMETERS
1000
STANDARD
MIN
SCL CLOCK FREQUENCY, fSCL
kbps
FAST
MAX
MIN
100
MAX
UNITS
400
kHz
Hold time for START and repeated
START condition, tHD_STA
5200
1300
ns
Data setup time before positive
edge on SCL, tSU_DAT
300
300
ns
Data hold time after negative edge
on SCL, tHD_DAT
300
300
ns
Setup time from SCL goes high to
STOP condition, tSU_STO
5200
1300
ns
Bus free time between STOP and
START conditions, tBUF
4700
1300
ns
1/fSCL
SCL
tHD_SDA
SDA
tSU_DAT
tSU_STO
tBUF
I2C Timing Diagram
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
6.
DIMENSIONS
Mating Connector: AVX
p/n 009159006551906
PINOUT
PIN
LABEL
DESCRIPTION
VCC
POWER
GND
GROUND
P0.05
PWM1*
P0.06
PWM2*
P0.09
PWM3*
P0.10
PWM4*
*Factory Default. GPIO can be configured for alternate input/ output
functionality. Please contact Eulum Design for more information.
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
7.
REGULATORY STATEMENTS
FCC Statement
Changes or modifications not expressly approved by the
party responsible for compliance could void the user’s
authority to operate the equipment.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received,
including interference that may cause undesired operation.
Note:
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy, and if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one or more of the following measures:
● Reorient or relocate the receiving antenna.
● Increase the separation between the equipment and receiver.
● Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
● Consult the dealer or an experienced radio/TV technician for help.
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
FCC Important Notes
1.Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits
set forth for an uncontrolled environment. This equipment
should be installed and operated with a minimum distance of
20cm between the radiator & your body. This transmitter must
not be co-located or operating in conjunction with any other
antenna or transmitter.
2. OEM Integrated Instructions
This device is intended only for OEM integrators under the following conditions:
● The antenna and transmitter must not be co-located with any other transmitter or antenna.
The module shall be only used with the integral antenna(s) that has been originally tested and
certified with this module.
● As long as the two (2) conditions above are met, further transmitter testing will not be
required. However, the OEM integrator is still responsible for testing their end-product for any
additional compliance requirements with this module installed (for example, digital device
emission, PC peripheral requirements, etc.)
● In the event that these conditions cannot be met (for example certain laptop configuration
or co-location with another transmitter), then the FCC authorization for this module in
combination with the host equipment is no longer considered valid and the FCC ID of the
module cannot be used on the final product. In these and circumstance, the OEM integrator
will be responsible for re-evaluating. The end product (including the transmitter) and obtaining
a separate FCC authorization.
● The module is limited to installation in mobile or fixed applications.
● The seperate approval is required for all other operating configurations, including portable
configurations with respect to Part 2.1093 and different antenna configurations.
● The OEM is still responsible for verifying compliance with FCC Part 15, subpart B limits for
unintentional radiators through an accredited test facility.
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523
RFM-CSB-3
3. End Product Labelling
The final end product must be labeled in a visible area with the following:
RFM-CSB-3: “Contains FCC ID: 2AJML- EUCSBM”
Any similar wording that expresses the same meaning may be used.
The FCC Statement below should also be included on the label. When not possible, the FCC
Statement should be included in the User Manual of the host device.
“This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may cause
undesired operation.”
4. Information regarding the end user manual
The OEM integrator has to be aware not to provide information to the end user regarding how
to install or remove this RF module in the user’s manual of the end product which integrates
this module. The end user manual shall include all required regulatory information/warning as
show in this manual.
CE Regulatory
This device is tested and compliant against the following standards. OEM integrators should
consult with qualified test house to verify all regulatory requirements have been met for their
complete device.
● EN 62479:2010
● EN60950-1:2006+A11.2009+A1:2010+A12:2011+A2:2013
● ETSI EN 201-489-1 V2.2.0(2017-03)
● ESTI EN 301 489-17 V3.2.0(2017-03)
● ESTI EN 300 328 V2.1.1(2016-11)
EULUM DESIGN LLC
6131 • Kellers Church Road • Pipersville • PA • 18947 • USA
EULUM DESIGN LTD
Unit 4 • Zone D •Chelmsford Road Ind. Est • Dunmow • CM6 1XG • UK
www.eulum.com
info@eulum.com
USA: +1 215 622 2652
UK: +44 (0) 1371 238523

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Language                        : en-GB
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c143 79.161424, 2017/09/22-11:52:47
Create Date                     : 2018:08:07 16:12:46+01:00
Metadata Date                   : 2018:08:07 16:12:47+01:00
Modify Date                     : 2018:08:07 16:12:47+01:00
Creator Tool                    : Adobe InDesign CC 13.1 (Macintosh)
Instance ID                     : uuid:1c706da3-1cc6-1b4e-b9f4-a58ab1a0777c
Original Document ID            : xmp.did:3f37313a-3899-46cb-ae69-eb4a99390529
Document ID                     : xmp.id:9edd208e-8361-4ca7-9757-cad75ca6e18b
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:f42d6c4b-1d72-4030-a587-98d73b243f98
Derived From Document ID        : xmp.did:8d05a7e4-9499-464b-9cf9-2b88aea76657
Derived From Original Document ID: xmp.did:3f37313a-3899-46cb-ae69-eb4a99390529
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 13.1 (Macintosh)
History Changed                 : /
History When                    : 2018:08:07 16:12:46+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Count                      : 14
Creator                         : Adobe InDesign CC 13.1 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AJML-EUCSB3

Navigation menu