Powerware series

Eaton 9135 UPS

Features
• Provides clean, continuous power to protect critical equipment and applications from power-related downtime, data
loss and corruption, and process interruption
• Saves valuable rack space by delivering 6000 VA/4200W in
only 3U
• Offers deployment versatility through rack and tower
installation options with rail kits and pedestals provided
• Increases availability with hot-swappable batteries and
power module
• Offers extended battery runtime options to power essential
systems for more than an hour during an outage

Product snapshot
Power rating:

6 kVA/4.2 kW

Voltage:

230V nominal,
200–250 Vac range

Frequency:

50/60 Hz (auto-sensing)

Configuration:

Rackmount (3U) or tower

Advanced power protection for:

•
•
•
•
•

Medium-density data centers
Banking and security systems
Manufacturing process control
Retail point-of-sale systems
Telecommunications/VoIP equipment

The Eaton® 9135 UPS, Powerware® series, resolves utility
power problems and supplies continuous, conditioned
power. You get clean power
for valuable IT and networking equipment, battery backup to gracefully handle utility
outages, and on-demand visibility into UPS status from
anywhere.

Get more usable power for
less cost
The 9135 provides exactly
the level of power protection
needed under the conditions
of the moment—optimizing
for both efficiency and performance. The more efficient the
UPS, the lower your utility
and cooling bills.

Under normal power conditions, the UPS can operate
in high-efficiency mode at
up to 97 percent efficiency.
In double conversion mode,
the UPS operates at up to 91
percent efficiency.

Double-conversion design
for superior reliability and
protection
In double conversion mode,
the 9135 is constantly monitoring power conditions—
regulating both voltage and
frequency. Even when presented with the most severe
power problems, this UPS’s
output remains within two
percent of nominal voltage.

With a wide range of acceptable input voltages, this UPS does
not depend on batteries to smooth out power fluctuations.
Batteries are conserved for those times when utility power
is highly unstable or completely out. If an outage occurs, the
9135 transfers to battery with no break in power, making this
an ideal UPS for equipment sensitive to voltage fluctuations.

More power in less space
High power density. The 9135 increases power density, delivering 6000 VA/4200W in only 3U of rack space, freeing more
rack space for IT and telecom equipments. Rail kits and tower
pedestals are included with every 9135 for flexible installation.

Rack model and EBM installation

This UPS is even more user-friendly than its predecessors
offering greater distribution capabilities, with eight IEC 10A
& two IEC 16A outlets to power multiple pieces of equipment
without a PDU.
You can combine the 9135 with an Eaton enclosure PDU (ePDU™)
to power an entire rack of equipment from a single power cord
input. ePDU outlets can be monitored, switched, sequenced
and managed individually, providing maximum flexibility in
distributing power from the 9135.

Maximum availability for critical systems

Hot swappable batteries

Battery runtime for minutes or hours. During a power outage,
internal batteries in the 9135 keep loads running long enough
to gracefully shut down systems. Add up to four external battery modules (EBMs) to deliver more than an hour of extended
runtime at full load—or hours under lighter loads. Each EBM
occupies only 3U of rack space. These battery modules are
hot-swappable and can be replaced at any time without interrupting UPS operation and load protection.
Maximum battery runtime for critical equipments. LanSafe
power management software enables independent control of
load segments. With this feature, you can manage scheduled
shutdowns and sequential startups of protected loads. During
a power outage, you could shut down power to less essential
loads to extend battery backup time for more critical devices.
When the load segments feature is used with optional Connect
UPS-MS connectivity cards, users can remotely re-boot locked-up network equipment. Simply access the ConnectUPS-MS
card over the network, and toggle the password-protected
load segment controller to get your network back online.

Load segments

ConnectUPS-MS Network Management Card web interface

2

EATON CORPORATION Eaton 9135 UPS

Service without downtime. The 9135 features hot-swappable
components and an automatic internal bypass. The UPS automatically switches to an alternate power path within the unit
if it senses a trouble condition with an internal component.
Users can even remove and replace the battery and power
modules without powering down the UPS or interrupting power to loads.

Visibility, control and management from anywhere
Local UPS status at a glance. An intuitive LCD interface provides detailed information and menu-driven functions for UPS
management. The entire display rotates for the best orientation, whether the UPS is used vertically as a tower unit or
horizontally in a rack. The blue, backlit LCD screen displays
four lines of alphanumeric information. LEDs clearly display
UPS status:
•
•
•
•

Load Protected
Downgraded Operation
Load Not Protected
UPS ON/OFF button

LCD rotatable display

Choice of connectivity options. Connectivity options are available for almost any networking environment. The standard
unit comes with USB and RS-232 serial communication ports
and a DB-9 dry contact port. You can customize your UPS by
adding MS-slot interface options for other types of communications.
1. Optional communication card

5

slot for Web/SNMP interface
Web/SNMP card

2. USB port

1

4

3. DB 9 serial port

3

4. DB 9 with five dry output

contacts

2

5. Remote power off

Unified management for power protection. The 9135 comes
complete with the Eaton Software Suite CD, including SNMPcompatible power management software providing control
and visibility over all your UPS systems. From a central vantage point anywhere within the reach of a network connection,
you can:
•

Establish prioritized shutdown of network devices and client/ server applications

•

Test all network-connected UPSs from one node

•

Stay informed of power problems via email broadcasts

Intelligent Power Manager (IPM)

MODELS
Description

Style number

Rating
(VA/
Watts)

Input
plug

Output receptacles

Dimensions
H x W x D, mm

Weight,
kg

103006722-6591

6000/4200

Hardwired

Hardwired + (2) C19, (8) C13

130 x 444 x 741

57

NA

NA

NA

130 x 444 x 650

77.5

Rack Tower Models
9135G-6000 R/T 3U

Extended Battery Modules
9135G-6000 EBM R/T 3U 103006723-6591
BATTERY BACKUP TIMES (IN MINUTES)*
Loads (VA/Watts)

Standards Internal Batteries

+1 EBM

2 EBMs

+3 EBMs

+4 EBMs

1000/700

36

132

232

332

433

2000/1400

13

52

95

140

184

3000/2100

10

40

74

110

146

4000/2800

7

29

53

80

107

5000/3500

5

22

41

62

83

6000/4200*

4

18

33

50

68

* Runtimes available for the 6 kVA model only. Battery backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc.

www.eaton.com/9135

3

Eaton 9135 UPS Product Focus
TECHNICAL SPECIFICATIONS
General
User interface

Communications
Graphical LCD with blue backlight and text in
English, French, German, Portuguese, Italian and
Spanish

LEDs

Four status-indicating LEDs

Topology

Double-conversion

Diagnostics

Full system self-test

UPS bypass

Automatic bypass

Dimensions

See models selection guide

Rail kit

Included with all units

Electrical Input
Nominal voltage

RS-232 standard, RS-232 cable provided

USB port

HID standard, for communicating with Windows XP/
Vista

Relay output

DB-9 Dry Contact-common alarm standard

Software

Intelligent Power Manager (IPM) and IPP

Optional
communication
cards

ConnectUPS-MS Network Management Card for direct
control and monitoring in SNMP-based ne works
ConnectUPS-MS Card with ModBus RTU interface
Serial Management Card-MS for integration to industrial environment and building management systems,
remote shutdown for IBM AS/400 systems

Environmental

230V
220V-240V
user selectable

Voltage range

156–280 Vac (output PF 0.7)

Power draw of UPS
(full load)

6000VA: 26A @230V

Recommended input- 35A
breaker rating
Frequency

50/60 Hz autoselect

Frequency range

40–70 Hz

Safety markings

CE, GS

EMC

IEC/EN 62 040-2 class A

Audible noise

Max 46 dB

Ambient operating

0˚C to +40˚C

Storage temperature

-20˚C to +40˚C with batteries and
-25˚C to +55˚C without batteries

Relative humidity

5–90% non-condensing

Heat Dissipation (BTUs/hr)
Operating mode

Electrical Output
Power factor

Serial port

0.7

On utility voltage

±2% of nominal regulation

On battery voltage

±2% of nominal regulation

Efficiency

>97% in high-efficiency mode; 91% in normal mode

Frequency regulation

±3% Hz online

Load crest factor

3 to 1

Efficiency

5 kVA

6 kVA

Normal

91%

1150

1350

Battery

86%

1650

1960

High efficiency

97%

370

450

Battery
Internal battery type

5.5Ah, sealed, lead-acid; maintenance free

Externa battery
modules

Up to four per 9135, rail kits included for rack
mounting

EBM battery type

5.5 Ah, sealed, lead-acid; maintenance free

Battery runtime

Four (4) minutes with internal batteries @100% load
(0.7 PF)
For additional details, see battery runtime chart

Battery recharge
time

Six (6) hours to recover 90 percent of nominal backup
time after 100 percent RCD load discharge

Battery replacement

Hot-swappable internal and external batteries

Start-on-battery

Allows start of UPS without utility input

In the interests of continual product improvement all specifications are subject to change without notice.

SINGAPORE
Tel : +65 6825 1684
Fax : +65 6825 1689
EatonSEA@eaton.com

INDONESIA
Tel : +62 21 522 6181
Fax : +62 21 522 6182

THAILAND
Tel : +662 946 6843
Fax : +662 519 0574

MALAYSIA
Tel : +603 7804 3618
Fax : +603 7803 6193

VIETNAM
Tel : +84 4 3936 5303
Fax : +84 4 3936 5307

Eaton is the trade name, trademark, and/
or service mark of Eaton Corporation or its
subsidiaries and affiliates.
® 2008 Eaton Corporation
All Rights Reserved
Printed in Singapore
July 2010



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Format                          : application/pdf
Title                           : untitled
Create Date                     : 2010:07:14 09:00:25+08:00
Modify Date                     : 2010:07:26 11:55:15+08:00
Metadata Date                   : 2010:07:26 11:55:15+08:00
Producer                        : Acrobat Distiller 8.1.0 (Macintosh)
Document ID                     : uuid:b0e65540-c69a-c848-be29-b79fabd8bc73
Instance ID                     : uuid:7770b26e-4412-4135-b719-9410c965d15b
Page Count                      : 4
EXIF Metadata provided by EXIF.tools

Navigation menu