Powerware series Eaton 9135 UPS Features • Provides clean, continuous power to protect critical equipment and applications from power-related downtime, data loss and corruption, and process interruption • Saves valuable rack space by delivering 6000 VA/4200W in only 3U • Offers deployment versatility through rack and tower installation options with rail kits and pedestals provided • Increases availability with hot-swappable batteries and power module • Offers extended battery runtime options to power essential systems for more than an hour during an outage Product snapshot Power rating: 6 kVA/4.2 kW Voltage: 230V nominal, 200–250 Vac range Frequency: 50/60 Hz (auto-sensing) Configuration: Rackmount (3U) or tower Advanced power protection for: • • • • • Medium-density data centers Banking and security systems Manufacturing process control Retail point-of-sale systems Telecommunications/VoIP equipment The Eaton® 9135 UPS, Powerware® series, resolves utility power problems and supplies continuous, conditioned power. You get clean power for valuable IT and networking equipment, battery backup to gracefully handle utility outages, and on-demand visibility into UPS status from anywhere. Get more usable power for less cost The 9135 provides exactly the level of power protection needed under the conditions of the moment—optimizing for both efficiency and performance. The more efficient the UPS, the lower your utility and cooling bills. Under normal power conditions, the UPS can operate in high-efficiency mode at up to 97 percent efficiency. In double conversion mode, the UPS operates at up to 91 percent efficiency. Double-conversion design for superior reliability and protection In double conversion mode, the 9135 is constantly monitoring power conditions— regulating both voltage and frequency. Even when presented with the most severe power problems, this UPS’s output remains within two percent of nominal voltage. With a wide range of acceptable input voltages, this UPS does not depend on batteries to smooth out power fluctuations. Batteries are conserved for those times when utility power is highly unstable or completely out. If an outage occurs, the 9135 transfers to battery with no break in power, making this an ideal UPS for equipment sensitive to voltage fluctuations. More power in less space High power density. The 9135 increases power density, delivering 6000 VA/4200W in only 3U of rack space, freeing more rack space for IT and telecom equipments. Rail kits and tower pedestals are included with every 9135 for flexible installation. Rack model and EBM installation This UPS is even more user-friendly than its predecessors offering greater distribution capabilities, with eight IEC 10A & two IEC 16A outlets to power multiple pieces of equipment without a PDU. You can combine the 9135 with an Eaton enclosure PDU (ePDU™) to power an entire rack of equipment from a single power cord input. ePDU outlets can be monitored, switched, sequenced and managed individually, providing maximum flexibility in distributing power from the 9135. Maximum availability for critical systems Hot swappable batteries Battery runtime for minutes or hours. During a power outage, internal batteries in the 9135 keep loads running long enough to gracefully shut down systems. Add up to four external battery modules (EBMs) to deliver more than an hour of extended runtime at full load—or hours under lighter loads. Each EBM occupies only 3U of rack space. These battery modules are hot-swappable and can be replaced at any time without interrupting UPS operation and load protection. Maximum battery runtime for critical equipments. LanSafe power management software enables independent control of load segments. With this feature, you can manage scheduled shutdowns and sequential startups of protected loads. During a power outage, you could shut down power to less essential loads to extend battery backup time for more critical devices. When the load segments feature is used with optional Connect UPS-MS connectivity cards, users can remotely re-boot locked-up network equipment. Simply access the ConnectUPS-MS card over the network, and toggle the password-protected load segment controller to get your network back online. Load segments ConnectUPS-MS Network Management Card web interface 2 EATON CORPORATION Eaton 9135 UPS Service without downtime. The 9135 features hot-swappable components and an automatic internal bypass. The UPS automatically switches to an alternate power path within the unit if it senses a trouble condition with an internal component. Users can even remove and replace the battery and power modules without powering down the UPS or interrupting power to loads. Visibility, control and management from anywhere Local UPS status at a glance. An intuitive LCD interface provides detailed information and menu-driven functions for UPS management. The entire display rotates for the best orientation, whether the UPS is used vertically as a tower unit or horizontally in a rack. The blue, backlit LCD screen displays four lines of alphanumeric information. LEDs clearly display UPS status: • • • • Load Protected Downgraded Operation Load Not Protected UPS ON/OFF button LCD rotatable display Choice of connectivity options. Connectivity options are available for almost any networking environment. The standard unit comes with USB and RS-232 serial communication ports and a DB-9 dry contact port. You can customize your UPS by adding MS-slot interface options for other types of communications. 1. Optional communication card 5 slot for Web/SNMP interface Web/SNMP card 2. USB port 1 4 3. DB 9 serial port 3 4. DB 9 with five dry output contacts 2 5. Remote power off Unified management for power protection. The 9135 comes complete with the Eaton Software Suite CD, including SNMPcompatible power management software providing control and visibility over all your UPS systems. From a central vantage point anywhere within the reach of a network connection, you can: • Establish prioritized shutdown of network devices and client/ server applications • Test all network-connected UPSs from one node • Stay informed of power problems via email broadcasts Intelligent Power Manager (IPM) MODELS Description Style number Rating (VA/ Watts) Input plug Output receptacles Dimensions H x W x D, mm Weight, kg 103006722-6591 6000/4200 Hardwired Hardwired + (2) C19, (8) C13 130 x 444 x 741 57 NA NA NA 130 x 444 x 650 77.5 Rack Tower Models 9135G-6000 R/T 3U Extended Battery Modules 9135G-6000 EBM R/T 3U 103006723-6591 BATTERY BACKUP TIMES (IN MINUTES)* Loads (VA/Watts) Standards Internal Batteries +1 EBM 2 EBMs +3 EBMs +4 EBMs 1000/700 36 132 232 332 433 2000/1400 13 52 95 140 184 3000/2100 10 40 74 110 146 4000/2800 7 29 53 80 107 5000/3500 5 22 41 62 83 6000/4200* 4 18 33 50 68 * Runtimes available for the 6 kVA model only. Battery backup times are approximate and may vary with equipment, configuration, battery age, temperature, etc. www.eaton.com/9135 3 Eaton 9135 UPS Product Focus TECHNICAL SPECIFICATIONS General User interface Communications Graphical LCD with blue backlight and text in English, French, German, Portuguese, Italian and Spanish LEDs Four status-indicating LEDs Topology Double-conversion Diagnostics Full system self-test UPS bypass Automatic bypass Dimensions See models selection guide Rail kit Included with all units Electrical Input Nominal voltage RS-232 standard, RS-232 cable provided USB port HID standard, for communicating with Windows XP/ Vista Relay output DB-9 Dry Contact-common alarm standard Software Intelligent Power Manager (IPM) and IPP Optional communication cards ConnectUPS-MS Network Management Card for direct control and monitoring in SNMP-based ne works ConnectUPS-MS Card with ModBus RTU interface Serial Management Card-MS for integration to industrial environment and building management systems, remote shutdown for IBM AS/400 systems Environmental 230V 220V-240V user selectable Voltage range 156–280 Vac (output PF 0.7) Power draw of UPS (full load) 6000VA: 26A @230V Recommended input- 35A breaker rating Frequency 50/60 Hz autoselect Frequency range 40–70 Hz Safety markings CE, GS EMC IEC/EN 62 040-2 class A Audible noise Max 46 dB Ambient operating 0˚C to +40˚C Storage temperature -20˚C to +40˚C with batteries and -25˚C to +55˚C without batteries Relative humidity 5–90% non-condensing Heat Dissipation (BTUs/hr) Operating mode Electrical Output Power factor Serial port 0.7 On utility voltage ±2% of nominal regulation On battery voltage ±2% of nominal regulation Efficiency >97% in high-efficiency mode; 91% in normal mode Frequency regulation ±3% Hz online Load crest factor 3 to 1 Efficiency 5 kVA 6 kVA Normal 91% 1150 1350 Battery 86% 1650 1960 High efficiency 97% 370 450 Battery Internal battery type 5.5Ah, sealed, lead-acid; maintenance free Externa battery modules Up to four per 9135, rail kits included for rack mounting EBM battery type 5.5 Ah, sealed, lead-acid; maintenance free Battery runtime Four (4) minutes with internal batteries @100% load (0.7 PF) For additional details, see battery runtime chart Battery recharge time Six (6) hours to recover 90 percent of nominal backup time after 100 percent RCD load discharge Battery replacement Hot-swappable internal and external batteries Start-on-battery Allows start of UPS without utility input In the interests of continual product improvement all specifications are subject to change without notice. SINGAPORE Tel : +65 6825 1684 Fax : +65 6825 1689 EatonSEA@eaton.com INDONESIA Tel : +62 21 522 6181 Fax : +62 21 522 6182 THAILAND Tel : +662 946 6843 Fax : +662 519 0574 MALAYSIA Tel : +603 7804 3618 Fax : +603 7803 6193 VIETNAM Tel : +84 4 3936 5303 Fax : +84 4 3936 5307 Eaton is the trade name, trademark, and/ or service mark of Eaton Corporation or its subsidiaries and affiliates. ® 2008 Eaton Corporation All Rights Reserved Printed in Singapore July 2010
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : untitled Create Date : 2010:07:14 09:00:25+08:00 Modify Date : 2010:07:26 11:55:15+08:00 Metadata Date : 2010:07:26 11:55:15+08:00 Producer : Acrobat Distiller 8.1.0 (Macintosh) Document ID : uuid:b0e65540-c69a-c848-be29-b79fabd8bc73 Instance ID : uuid:7770b26e-4412-4135-b719-9410c965d15b Page Count : 4EXIF Metadata provided by EXIF.tools