Eaton HHB2BATR Wireless Sensor User Manual Temp Sensor P2
Eaton Corporation Wireless Sensor Temp Sensor P2
Eaton >
Contents
- 1. Manual Temp Sensor P1
- 2. Manual Temp Sensor P2
Manual Temp Sensor P2
Temperature Sensor Set up CARRY the sensor, battery, and the Home Key to the location where you want to place it. OPEN the sensor cover and insert the battery. The green LED light inside the sensor should flash four times if the battery is good. Close the cover. CLICK the Home Key thumbwheel to wake the screen, and SLIDE the Home Key into the Slide Channel on the top of the sensor. The Home Key screen should say: Please wait… Device found OK to remove Key. Device found OK to remove Key... Follow the instructions on the Home Key screen to join the sensor to the system, name it, and set In-Home Awareness and "CallMe" Awareness. After options are set and you click Done, go back?, the Home Key screen will indicate that the sensor is joined to the system. You may go to Step 2. If you slide the Home Key into the sensor Slide Channel and the Home Key screen shows either of the following messages, it means that the Home Key or sensor may be outside the range of the Base Station. Remove Key... Please try again Sensor out of range? Remove Key... Can't set up now Key out of range If the Home Key or sensor is out of range, you can: • Add a Home Heartbeat ™ Range Extender between the Base Station and Sensor, or Slide the Home Key into the Slide Channel of the Temperature Sensor. If the Home Keyis not out of range, the new threshold setting will now be registered with the sensor. Check that at room temperature the sensor reports 'Below temp' on the Home Key for the 100° F threshold setting. • Select an alternate location for the Sensor, or • Try moving the Base Station to a more central location in your home. Then, complete Step 1 again. Test ROLL OVER and highlight the Temperature Sensor icon on the Home Key. The initial temperature threshold of your Temperature Sensor is set at 40° F. Check that the sensor reports 'Above temp' on the Home Key at room temperature. DOUBLE-CLICK the Home Key thumbwheel Temp Sensor on the Temperature Sensor icon to reveal Above temp for 5 secs the control menu. Use the 'Change threshold?' option to set a new temperature threshold above room temperature, e.g. 100° F. Place and use MOUNT the Temperature Sensor in the measurement location by attaching the enclosed adhesive tape on the back .* Set the required temperature threshold using the Home Key, following the procedure described in the test. If you would like an immediate temperature threshold update, slide Home Key into the sensor Slide Channel. Otherwise, please allow up to one hour for the new settings to take effect. * Be sure that the area of installation is clean and dry. Need help? Call 1-800-813-2199 for customer support or visit www.homeheartbeat.com If Your Temp Sensor . . . Temp Sensor Below temp for 5 secs • will not respond, make sure the battery in the sensor is installed correctly. • does not send a signal to the Base Station, move the sensor and Base Station closer together (or consider getting a Home Heartbeat Range™ Extender).
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Format : application/pdf Title : Temp Sensor P2 Creator Tool : Adobe Illustrator CS3 Create Date : 2008:05:08 11:04:35-04:00 Modify Date : 2008:05:13 08:33:57-05:00 Metadata Date : 2008:05:13 08:33:57-05:00 Thumbnail Width : 256 Thumbnail Height : 152 Thumbnail Format : JPEG Thumbnail Image : (Binary data 13248 bytes, use -b option to extract) Document ID : uuid:09A809710F1DDD11B2DDE6546C3ECC65 Instance ID : uuid:453dd25c-2b81-4e83-b9ef-94a357ef5730 Derived From Instance ID : uuid:08A809710F1DDD11B2DDE6546C3ECC65 Derived From Document ID : uuid:83C499151CDE11DD83AFE31F7BB59DFE N Pages : 1 Has Visible Transparency : False Has Visible Overprint : False Max Page Size W : 9.875000 Max Page Size H : 5.062500 Max Page Size Unit : Inches Font Name : Basis, Univers-CondensedBold, Univers-CondensedOblique, Univers-Condensed, Univers-CondensedLight, Basis-Regular Font Family : Basis, Univers, Univers, Univers, Univers, Basis Regular Font Face : Regular, 67 Bold Condensed, 57 Condensed Oblique, 57 Condensed, 47 Light Condensed, Regular Font Type : TrueType, Type 1, Type 1, Type 1, Type 1, Unknown Font Version : Version 1.000 2005 release, 001.001, 001.002, 001.002, 001.001, Version 2.007;PS 002.000;Core 1.0.38;makeotf.lib1.7.9032 Font Composite : False, False, False, False, False, False Font File Name : BasisReg.ttf, uvcb____.PFB; uvcb____.pfm, uvcdo___.PFB; uvcdo___.pfm, uvc_____.PFB; uvc_____.pfm, uvcl____.PFB; uvcl____.pfm, MyriadPro-Regular.otf Plate Names : Black, PANTONE 431 C, PANTONE 314 C Swatch Group Name : Default Swatch Group Swatch Group Type : 0 Swatch Colorant Swatch Name : White, Black, Yellow, Lime, Night Blue, PANTONE 431 C, PANTONE 314 C, PANTONE 369 C Swatch Colorant Mode : CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK Swatch Colorant Type : PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, SPOT, SPOT, SPOT Swatch Colorant Cyan : 0.000000, 0.000000, 0.000000, 32.999998, 100.000000, 11.000000, 100.000000, 58.999997 Swatch Colorant Magenta : 0.000000, 0.000000, 0.000000, 0.000000, 50.000000, 1.000000, 0.000000, 0.000000 Swatch Colorant Yellow : 0.000000, 0.000000, 100.000000, 72.999996, 0.000000, 0.000000, 9.000000, 100.000000 Swatch Colorant Black : 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 63.999999, 30.000001, 7.000000 Swatch Colorant Tint : 100.000000, 100.000000, 100.000000 Producer : Adobe PDF library 8.00 Page Count : 1 Creator : Adobe Illustrator CS3EXIF Metadata provided by EXIF.tools