Ecolink Intelligent Technology SS319 WIRELESS SENSOR User Manual Manual

Ecolink Intelligent Technology, Inc. WIRELESS SENSOR Manual

Manual

SS-319 Wireless Siren
Specifications
Frequency: 319.508MHz Operating Temperature: 32°-120°F (0°-49°C)
Battery: 3.6V NiMH rechargeable 3 cell pack Operating Humidity: 5-95% RH non condensing
Battery life upon power loss: 24 hours Compatible with UTC Interlogix panels
Supervisory signal interval: 60 min(approx.)
Installing the Wireless Siren
Connect the Battery
The Wireless Siren uses a NiMH rechargeable battery pack, included. Remove the battery cover on the back of
the siren and insert the battery pack. Plug the battery pack connector to the two pin connector on the Siren.
Reattach battery door.
Mounting
Plug Wireless Siren into constant power AC outlet.
An optional screw mount is available to prevent easily unplugging the device. Using a screw driver or other
tool, remove the thin layer of material in the center of the screw tab on the Siren. Next, remove the center
screw of the wall plate on the AC outlet you are plugging the Siren into. You may either use that same screw
you just removed from the AC outlet, or use the longer screw that is included in the Siren packaging. Place
the cover plate of the AC outlet on, and then plug in the Siren WITH THE SCREW TAB POINTING TOWARDS
THE FLOOR. Insert screw through the Siren screw tab and tighten Siren and wall plate so the Siren is tight to
the wall plate.
Enrolling
To enroll the siren, set your panel into program mode, refer to your specific alarm panel manual for details on
these menus. When prompted by the panel, trigger the siren by pressing the LEARN button on the side of the
siren. If successfully enrolled, you will see the LED flash, and the alarm panel will BEEP.
Enable/Disable Chime Feature
Enable:
Make sure the chime feature has been turned on in the Interlogix panel first.
Simultaneously press the LEARN and TEST buttons on the side of the Siren for 2 seconds.
LED will remain on , and the siren module will BEEP, indicating the chime feature is ON
Disable:
The chime function can be on or off in the Interlogix panel, this will not affect disabling Wireless
Siren’s chime function.
Simultaneously press the LEARN and TEST buttons on the side of the Siren for 2 seconds.
LED will blink off, and the siren will not chirp, indicating the chime feature is Off.
Range Test
After the SS-319 Siren has been learned into the panel, an RF range test can be initiated. To do this, press the
test button for one second. This will cause the siren to send 8 test packets to the panel, and the LED on the
siren will blink each time a packet is sent. As the panel receives each of the 8 packets, it will send an
acknowledgement packet back to the Siren. The Siren will chirp each time an acknowledgement is received.
As an example, if the button is pressed for one second, and then 7 chirps are heard from the siren, that
indicates that 7 out of 8 test packets were successfully received by the panel and acknowledged back to the
siren. This means that either one packet was not received by the panel, or that the acknowledgement back
from the panel was not received by the Siren.
Factory Reset
In case you want to return the Wireless Siren to a factory default state, press and hold BOTH buttons on the
side of the Siren for 10 seconds. When successful, the LED will FLASH XXXX, and you will hear the Siren BEEP
XXXX times.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment to an outlet on a different circuit from the receiver
Consult the dealer or an experienced radio/TV contractor for help.
Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne
peut pas provoquer d'interférences, et (2) c’et appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement
de la dispositif.
FCC ID:XQC-SS319 IC: 9863B-SS319
Warranty
Ecolink Intelligent Technology Inc. warrants that for a period of 5 years from the date of purchase that this product is free from defects in material and workmanship.
This warranty does not apply to damage caused by shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper
maintenance, failure to follow instructions or as a result of any unauthorized modifications. If there is a defect in materials and workmanship under normal use
within the warranty period Ecolink Intelligent Technology Inc. shall, at its option, repair or replace the defective equipment upon return of the equipment to the
original point of purchase. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed
or implied and of all other obligations or liabilities on the part of Ecolink Intelligent Technology Inc. neither assumes responsibility for, nor authorizes any other
person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. The maximum
liability for Ecolink Intelligent Technology Inc. under all circumstances for any warranty issue shall be limited to a replacement of the defective product . It is
recommended that the customer check their equipment on a regular basis for proper operation.