Electronics PA-PK Self-Contained Door Lock User Manual Manual
International Electronics Inc. Self-Contained Door Lock Manual
Manual
Installation Instructions For Low Profile Mortise Lock A7454A Table of Contents Page 1 Warning .......................................................1 2 General Description .........................................2 3 Specifications ................................................2 4 Parts Breakdown............................................3-5 5 Features .......................................................5 6 Installation Instructions...................................6-13 7 Operational Check ..........................................14 8 Basic Programming Instructions .........................14 Keypad Only (100 Users–LK) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Keypad or Proximity/Keypad (500 Users–LU or PK). . . . . . . . . . . . . . . 18 Proximity Only (500 Users–PA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 9 Chain Programming ........................................23 10 Transaction Log .............................................24 1 Warning Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced TV technician for help. This Class B digital apparatus complies with Canadian ICES-003 Cet appareil numÈrique de la classe B est conforme ‡ la norme NMB-003 du Canada 2 General Description The SARGENT Keypad Mortise Lock/Prox is designed for areas which require authorized entry. It is a self-contained microprocessor-controlled keypad with non volatile solid-state memory. The keypad will hold a total of 100(LK) / 500(LU, PK, PA) different User Codes. User Codes “01”, “02”, and “03” are utilized for Master Code, Emergency Code, and Supervisory Code, respectively. This product is operated by six (6) “AA” Duracell Alkaline Batteries. SARGENT mortise locks are designed with high quality components to provide the high security, performance and durability. Warning To comply with “Fire Listed” doors, the batteries must be replaced with Alkaline batteries only. 3 Specifications • Latchbolt - Stainless Steel • Deadbolt - Stainless Steel • Outside lever controlled by Keypad, Keypad/Prox or Prox only • Handed - Easily field reversible without disassembling the lock body • Inside lever retracts latchbolt and deadbolt • Locks furnished for 1 3/4" doors. Can be furnished for other door sizes upon request. Consult factory • Case - 12 gauge heavy duty wrought steel • U.L. Listed (3 hr.) • Guardbolt - Stainless Steel, non handed 4 Parts Breakdown ’A’ DESIGN (LH) ’A’ DESIGN (RH) ’E’ DESIGN ’B’ DESIGN ’F’ DESIGN ’H’ DESIGN ’J’ DESIGN ’P’ DESIGN ’L’ DESIGN ’W’ DESIGN 12 13 13 26 30 21 17 33 24 16 22 11 26 15 24 25 20 23 31 14 16 21 15 17 22 18/19 20 11 29 27/28 Parts Breakdown (Continued) Item # Part# Description 82-3846 82-3847 82-3848 82-3849 82-0493 82-0495 82-3837 82-3838 82-3839 82-3840 82-3841 82-3842 82-0492 82-0494 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 52-2437 01-1212 01-0297 82-0507 77-0772 01-0844 01-0543 77-0168 52-0033 01-1500 82-3088 01-1495 82-0368 82-0347 82-0081 82-0084 01-1028 01-2299 01-1019 82-0184 01-0079 82-3082 81-0723 01-1472 01-1174 81-0467 81-0468 81-0490 81-0470 81-0471 81-0447 81-0489 81-0513 81-0445 Outside Escutcheon with Cylinder Hole and Key Pad, or Key Pad / Prox Outside Escutcheon without Cylinder Hole and Key Pad or Key Pad / Prox Outside Escutcheon with Cylinder Hole and Prox Only Outside Escutcheon without Cylinder Hole and Prox Only Outside Escutcheon Housing Only with Cylinder Hole Outside Escutcheon Housing Only without Cylinder Hole 52-2431 Proximity Circuit Board and Harness Assembly 52-2432 Key Pad / Proximity Circuit Board and Harness Assembly Inside Escutcheon with Thumb Turn and 100 User Controller Inside Escutcheon without Thumb Turn and 100 User Controller Inside Escutcheon with Thumb Turn and 500 User Controller Inside Escutcheon without Thumb Turn and 500 User Controller Inside Escutcheon with Thumb Turn Prox / Key Pad Controller Inside Escutcheon without Thumb Turn Prox / Key Pad Cont. Inside Escutcheon Housing Only without Thumb Turn Inside Escutcheon Housing Only with Thumb Turn 52-2440 100 (LK) User Key Pad Controller Assembly 52-2447 500 (LU, PK) User Key Pad Controller Assembly 52-2454 Key Pad / Proximity (PK), Proximity Only (PA) Controller Assembly Battery Cover Assembly Security Screw Security Tool Thumb Turn Spindle (Thumb Turn) Washer (Thumb Turn) Spring Grip Fastener (Thumb Turn) Thru Bolts #8-32 x 1 7/8” Flat Head Screw Fire Stop Plate Fire Stop Screws #8 x 1/2” Type “AB” Phillips Pan Head Self Tap Inside Spindle Adapter & Plate Assembly Screw #8-32 x 1/2” Inside Spindle / Outside Spindle Inside Spring / Outside Spring Face Plate no Dead Bolt Face Plate with Dead Bolt Face Plate Screws Machine 8-32 x 1/4” Lock Body Screws / Wood Door #12 x 1 1/4” Lock Body Screws / Metal Door 12-24 x 1/2” Cap Nut Washer Plate Assembly Post Lever Handle Screw, A, E & F Lever Lever Handle Screw, B, J, L, P & W Lever Inside Lever (L.H.) "A" Design Inside Lever (R.H.) "A" Design Inside Lever "B" Design Inside Lever "E" Design Inside Lever "F" Design Inside Lever "J" Design Inside Lever "L" Design Inside Lever "P" Design Inside Lever "W" Design # Required Parts Breakdown (Continued) Item # 30 31 32 33 Part# Description 82-0151 82-3074 82-0152 82-3073 82-0153 82-0154 82-3074 82-0155 82-3076 82-3079 82-0156 82-0157 82-0158 82-0159 82-3732 82-3733 01-0803 52-0253 O/S Lever Handle R.H. "A" Design O/S Lever Handle R.H. "A" Design Stainless Steel O/S Lever Handle L.H. "A" Design O/S Lever Handle L.H. "A" Design Stainless Steel O/S Lever Handle "B" Design O/S Lever Handle "E" Design O/S Lever Handle "E" Design Stainless Steel O/S Lever Handle "F" Design O/S Lever Handle "F" Design Stainless Steel O/S Lever Handle "H" Design O/S Lever Handle "J" Design O/S Lever Handle "L" Design O/S Lever Handle "P" Design O/S Lever Handle "W" Design Lockbody Assembly (with deadbolt) (8276 & 8277) Lockbody Assembly (without deadbolt) (8278 & 8279) Battery Alkaline ("AA" cell) Battery Keeper # Required 5 Features • Non volatile memory • Cylinder override optional • Motor driven, battery operated mortise lock • Entry of three wrong User Codes disables all codes for ten seconds. Yellow LED on solid • Battery operated with 6 each “AA” Alkaline • Low battery alert–4 chirps after code entry • External remote “request to exit” connector • Piezo horn can be heard with each keystroke or turned off by Master or Supervisory Code • Supervisory code will unlock door when low battery had expired • Last 15 (LK) transactions can be output to portable printer via infrared link • 100 (LK) or 500 (LU, PK, PA) users total • Last 1000 (LU, PK, PA) transactions can be output to portable printer via infrared link or PC via Soflink™ Plus software • Programming done at keypad or with Soflink™ Plus software and a PC (LU, PA, PK). Soflink™ Plus Software User Manual A7462 • Proximity FOB or Card optional • Deadbolt switch inside mortise lock allows Emergency Code and Master Code holders to gain entry when deadbolt is thrown • Operates utilizing any two to six digits per code. Digits may be repeated and codes may start with zero 6 Installation Instructions • Verify hand and bevel of door Right Hand Hinges Right Open Inward. "RH" Left Hand Reverse Bevel Hinges Left. Open Outward "LHRB" Left Hand Hinges Left. Open inward. "LH" Right Hand Reverse Bevel Hinges Right. Open Outward. "RHRB" Lock Body Latchbolt Right Hand Left Hand Reverse Bevel Bevel Right Hand Reverse Bevel • View lock body from top and from the outside (as shown above) Top Connector and Wires Front Deadbolt Latchbolt Lock w/cylinder Override (Shown) End Cap Guardbolt Installation Instructions (Continued) Door Preparation Thrubolt hole Hole for ribbon cable from controller to keypad Outside of Door Inside of Door Inside Cylinder Hole Thumb Turn Lever Hole Outside Cylinder Hole Mortised area Lever Handle Hole Lever Handle Hole Thrubolt hole Pre-drilled and /or Tapped Holes 2 places NOTE: Always consult the proper template prior to drilling any holes. Installation Instructions (Continued) How to Reverse Lock Hand If it is necessary to change hand of locking piece : 1. Turn lockbody to side NOT marked with RED locking piece. Connector 2. Insert blade of common screwdriver into locking piece slot. 3. Push locking piece toward front of lockbody and rotate until RED shows. 4. RED indicates locked (outside) side. 5. Wire harness MUST exit thru non-cylinder side. End Cap Locking RED color guide slot locking piece Push in indicates locked side Right Hand Shown If it is necessary to change hand Latchbolt : 1. Insert blade of common screwdriver into oval slot behind latchbolt. 2. Push latchbolt out until back of bolt clears lockbody front. 3. Rotate latchbolt 180¡ until the latchbolt drops back into the lockbody. End Cap Oval slot Push out Push out Rotate Latchbolt Outside of Door Installation Instructions (Continued) Step #1 Installation of Lockbody/Attaching Lockbody Screws • Wires and Connector go into the mortised area and out of the inside cylinder hole Inside of Door MUST feed Connector & Wires thru non-cylinder side. (2) #12-24 x 1/2" long Flat Head Screw for metal doors (2) #12 x 1 1/4" long Flat Head Wood Screw for wood doors • Insert Lockbody in mortised cutout • Hold loosely in place with (2) Lockbody screws • DO NOT TIGHTEN SCREWS AT THIS TIME Installation Instructions (Continued) Step #2 Attaching of Fire Stop Plate NOTE: Fire stop plate is required on all fire rated doors (2) 1/8" Dia holes required CL Of 1 1/2" Dia 7" Slot 11" (2) Self Tapping Screws #8 x 1/2" long for wood & metal doors Outside of Door 10 Installation Instructions (Continued) Step #3 Installation of Outside/Inside Escutcheon & Lever Assembly To secure the adapter and plate assembly to the inside of the door, thread the screws mounting posts of the outside lever assembly. From the outside of the door, feed wires and connector through fire stop plate Keypad/prox connector and cable Mortise lockbody connector and wire Tighten retaining nut by hand. Back off retaining nut slightly until star pattern lines up with square lever assembly corners Insert Spindle into square hole on inside of door. With outside lever horizontal, carefully insert the mounting posts through the door and lockbody. Make sure the spindle is properly engaged in the lock. NOTE: For installation of optional gasket Part #82-0500 see Gasket Installation Plug Keypad Connector into inside Escutcheon as shown. Place excessive wire in hole. Plug smaller Connector as shown into the inside Escutcheon. Place excessive wire in inside escutcheon assembly. Keep excessive wires away from cylinder hole. NOTE: Both connectors go on only one way. Do not offset the connectors. Be sure connectors are seated completely. If not seated, Keypad will not function properly. *8-32 Flat Head Screw Outside of Door Locate (2) #8-32 Flat Head Screw and insert through the escutcheon into the outside escutcheon. Tighten firmly. 11 Installation Instructions (Continued) Step #4 Installation of Inside Lever/Outside Cylinder • Align cylinder • Put the turn lever in the up position • Screw cylinder lockbody unit Type 43 Mortise Cylinder ONLY Inside Lever Key • Inside of Door Outside of Door Set Screw • Slide lever handle onto spindle until fully seated. Be sure handle is horizontal and facing to the rear of door • Tighten the set screw securely with 1/8" hex wrench • Tighten the set screw to prevent unscrewing of the cylinder • Turn the key way in the cylinder to make certain that the locking or latching mechanism function correclly. Set screw NT SARGENT RG Note: Key and the cylinder must be rotated as shown Very Important SA Phillips screwdriver Correct Wrong 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2001:05:15 10:04:54-07:00 Create Date : 2001:05:15 10:04:36-07:00 Producer : Acrobat Distiller 4.0 for Macintosh Page Count : 14EXIF Metadata provided by EXIF.tools