Electronique Telematique ETELM Canada BSTETRA460 Tetra Base Station User Manual netis B maintenance guide V1 1
Electronique Telematique ETELM Canada Inc Tetra Base Station netis B maintenance guide V1 1
Contents
netis B maintenance guide V1.1.part3
8.1.1.2 IT configuration on the Switch We will use the network management terminal to identify the link it number to the SWITCH as well as the position in the SWITCH rack of COM3 in charge of the link: Position 1 to 12 for a standard chassis. In CONFIGURATION / SETTINGS. Right click on a BS then select Name Tc/Ts. The window below appears. The G703 link configuration has a red border: Junction: Link type Voice/@IP: corresponds to the link it number Board: corresponds to the location of the COM3/4 board in the SWITCH (Counting from the SUPIP) The Tx=Rx check box means that the dialogue it is identical for both sides of the link. For the In and Out settings and the preferred direction refer to paragraph 9.1.2 Ring Network The In and Out list zones must be filled in as in the window: Ins: for the link the SWITCH 0/1 SW precedes the BS for consultation Outs: for the link, no equipment succeeds the BS for consultation Fault analyses and diagnosis NeTIS MAINTENANCE GUIDE – Version 1.1 71/139 8.2 « Ring » network NeTIS MAINTENANCE GUIDE – Version 1.1 72/139 8.2.1 OPERATING PRINCIPLES Link type: always G703 Type of module in charge of the link: COM 3/4 Normal operations: (see §9.1.2.2) Each NeTIS-N appliance transmits data to the NeTIS-Bs on an it in both directions of the loop and extracts data from the NeTIS-Bs only from one direction at a time Each NeTIS-B appliance transmits data to the NeTIS-Ns on an it in both directions of the loop and extracts data from the NeTIS-Ns only from one direction at a time depending on the preferred direction selected in the settings More precisely, the COM3 or COM4 board plays the role of G703 interface on the BS side and the SWITCH side, it permanently transmits on both G703 junctions; The signal received at these junctions are analysed and the indicators on the front face make it possible to know the state of these junctions: 'ERR’ indicator: red indicator lighting when a line error is detected on the junction or if there is no 2Mb/s signal (disconnection for example). Yellow 'Rx’ indicator: flashes when a G704 synchronisation is detected; stays on when a synchronisation is detected and the link with the switch is established. SWITCH Carte(s) COM Carte COM Site 1 Carte(s) COM Carte COM REBOUCLAGE Site i Carte COM Site 2 Carte COM Site 3 NeTIS MAINTENANCE GUIDE – Version 1.1 73/139 In the case of correct reception on both sides (A and B), the COM board only keeps the signals received from the side declared as preferred (settings on the network management terminal). The board injects signals corresponding to the TBS11 in the assigned time slot (programming on the rear face of the NeTIS-B see §9.1.1.1) on both junctions A and B at the same time and transparently retransmits the other time slots, in both directions from one junction to the next and vice versa. 8.2.2 FAULT ANALYSES AND DIAGNOSIS 8.2.2.1 Presentation We are going to study a network composed of: A SWITCH A one BS SITE N° 1 A one BS SITE N° 2 The network architecture is shown below: Here its operation is correct NeTIS MAINTENANCE GUIDE – Version 1.1 74/139 8.2.2.2 NeTIS-B configuration Each NeTIS-B on the network must be configured to work on an it from the G703 link (see §9.1.1.1) 8.2.2.3 NeTIS-N configuration The SWITCH is configured via the network management terminal A double click on the SWITCH in monitoring mode displays the following window All the connected resources in the SWITCH are visible To find out the role of each of the COM3 or 4 boards, view the BS states To do this access the SYNOPSIS area of the network management terminal and double click on the BS NeTIS MAINTENANCE GUIDE – Version 1.1 75/139 Click Double Click COM board location in the SWITCH in charge of direction A COM board location in the SWITCH in charge of direction B The COM3 and COM4 board locations in the SWITCH and it is used on the network are configured as follows: Right click on the BS, and then click on Name TC TS and select the Communications link NeTIS MAINTENANCE GUIDE – Version 1.1 76/139 NeTIS MAINTENANCE GUIDE – Version 1.1 77/139 8.2.2.4 Fault N° 1: Link cut between the SWITCH and the BS for site 1 and the network is operational in the B direction. Network management terminal synopsis view NeTIS MAINTENANCE GUIDE – Version 1.1 78/139 NeTIS MAINTENANCE GUIDE – Version 1.1 79/139 Direct observation on the COM3 boards: NeTIS MAINTENANCE GUIDE – Version 1.1 80/139 Messages in the network management terminal history/tickets 8.2.2.5 Fault N°2: Link cut between the two radio sites Site 1 is connected to the Switch in direction A Site 2 is connected to the Switch in direction B Network management terminal synopsis view NeTIS MAINTENANCE GUIDE – Version 1.1 81/139 Direct observation on the COM3 boards: #$% "# #$% ! "# $% NeTIS MAINTENANCE GUIDE – Version 1.1 82/139 Messages in the network management terminal history/tickets 8.2.2.6 Fault N°3 Link cut between the SWITCH and site 2 Both sites are connected to the Switch in direction A Network management terminal synopsis view NeTIS MAINTENANCE GUIDE – Version 1.1 83/139 Direct observation on the COM3 boards #$% "# #$% ! "# $% & NeTIS MAINTENANCE GUIDE – Version 1.1 84/139 Messages in the Network management terminal history/tickets 8.3 Ethernet link (IP) This chapter describes the different types of IP exchanges between the different BSs, Operator stations, Phone gateways, etc... for a TETRA IP network. 8.3.1 GENERAL PRESENTATION The general architecture of a TETRA network uses several elements: Base stations communicating with mobiles and linked to the switch(es) One or more switches (that can be linked together) eventually interconnected to external networks (phone networks) One or more operator stations. Various applications (Recorder, phone gateways, etc ...) NeTIS MAINTENANCE GUIDE – Version 1.1 85/139 B IP IP SWITCH IP SWITCH SWITCH PABX PSTN Others applicatif IP All the elements of the radio network are linked together through an IP network. The radio network clients (BS, Operator station, etc ...) have a minimum configuration, adding an element must not cause the reconfiguration of existing elements. NeTIS MAINTENANCE GUIDE – Version 1.1 86/139 8.3.2 COMMUNICATIONS BETWEEN APPLIANCES NeTIS MAINTENANCE GUIDE – Version 1.1 87/139 NeTIS MAINTENANCE GUIDE – Version 1.1 88/139 8.3.3 CUSTOMERS 8.3.3.1 Phone applications These applications need to use signalling and phone. (Operator stations, Phone gateways, etc.). Operator station Customer UDP Identification Customer UDP Signalisation TCP Customer to highest priority SWITCH UDP reception UDP reception Reception of all switches present on the network and management of a dynamic switch table. Switch signalling channel reception with the highest priority for communications management. Link with the highest priority switch for communications management, it is the "active" link. TCP/IP links Phone UDP customer UDP broadcast TCP customer to lower priority switch TCP/IP links Reception of transmission from the PHONE channel Link with the lowest priority switch and connection with the highest priority switch that arrives on the network. IP NeTIS MAINTENANCE GUIDE – Version 1.1 89/139 8.3.4 NETWORK SETTING 8.3.4.1 Role of the UDP Identification Server Each switch broadcasts an identification message on a UDP channel permanently (every 5 seconds). The UDP port number used for this broadcast is therefore part of the minimum information needed in the Clients (NeTIS-B, Operator Station etc...) wanting to connect to the radio network. This message makes it possible for the BSs to send information about themselves to the servers (NeTIS-N): CPU IP addresses, Switch N°, SUP IP addresses Then the SWITCHES send the following information to the clients: IP address and Port of the BS signalling server (see §9.3.4.4) IP address and Port of the BS Phone server (see §9.3.4.4) The port used to broadcast this message and the broadcasting address are set via the network management terminal and transmitted to the NeTIS-N by downloading. A file in the NeTIS-B is used to declare the identification port used by the NeTIS-N(s). 8.3.4.2 UDP identification server configuration The UDP identification server is in fact the NeTIS-N The server is configured from the network management terminal as shown below In NeTIS MAINTENANCE GUIDE – Version 1.1 90/139 Select « IGMP » tab The broadcast of server information (NeTIS-N) to the clients (NeTIS-B) is carried out using a Broadcast address and is defined as shown below Select the "Configuration" tab NeTIS MAINTENANCE GUIDE – Version 1.1 91/139 8.3.4.3 Port identification declaration on the NeTIS-B side A base station that wants to connect to the tetra network listens on its identification port in order to obtain the information from the different SWITCHES on the network with their priority level. To declare this port, a configuration file (Text) stored on the NeTIS-B must be read the path of which is /USR/BsLinux/nano CONFIGBS.CFG. Below the content of the CONFIGBS.CFG file shows that the identification port is "51114" "Top of file ######### IP PARAMETERS Commands to close the file for example: CTRL X(^ X) IDENTIFICATION PORT N° PORT_IDENTIFICATION = 51114 [ Read 62 lines ] ^G Get Help ^O WriteOut ^R Read File ^Y Prev Page ^K Cut Text ^C Cur Pos ^X Exit ^J Justify ^W Where Is ^V Next Page ^U UnCut Txt ^T To Spell "End of file 8.3.4.4 IP Network without using the identification port If the port is not filled in in the BS, then port "51114" is used as a default. It is not mandatory to use the identification port. If you know the SWITCH IP addresses (CPU and SUPIP) and the signalling and phone ports that are used, then they can be added to the CONFIGBS.CFG file as shown below. "Top of file ACTIVE SW CPU+signalling port ######### IP PARAMETERS ACTIVE SW SUPIP+Phone port (§9.3.4.5) IP_SWITCH = 192.168.1.100 PORT_SWITCH = 50020 IP_SUPIP = 192.168.1.3 PORT_SUPIP = 50021 [ Read 62 lines ] ^G Get Help ^O WriteOut ^R Read File ^Y Prev Page ^K Cut Text ^C Cur Pos ^X Exit ^J Justify ^W Where Is ^V Next Page ^U UnCut Txt ^T To Spell NeTIS MAINTENANCE GUIDE – Version 1.1 92/139 "End of file 8.3.4.5 Checking the IP configuration on the BS side Once the Niveau2 software is running it is possible to activate different network management terminal using the ALT+Fx keys, without disturbing the current application Connect a screen and keyboard and press the "ALT F2" and "L" keys, the display below appears: Port used for maintenance (Spy etc.) "start of display * 0 client connected with server 4 on port 55555 , socket 16 *** NbClient=0 found=0 Port used for maintenance (Spy etc.) * Connected at server no 0 : 192.168.1.124 port=50400 with socket 14 (69s) Bs connected to the switch SWITCH CPU IP address BS Signalling port Socket N° * Connected at server no 1 : 192.168.1.125 port=50401 with socket 15 (69s) Bs connected to the switch SWITCH SUPIP IP BS Phone Port Socket N° --> UDP Address UDP 0: 192.168.1.121 port : 50300 TX_ONLY socket=19 UDP Protocol BS IP address SWITCH CPU signalling port Port open in the TX --> UDP Address UDP 3: 192.168.1.121 port : 50401 FULL_DUPLEX socket=12 UDP Protocol BS IP address BS Phone Port NeTIS MAINTENANCE GUIDE – Version 1.1 Port open in TX and RX 93/139 --> UDP Address UDP 4: 192.168.1.121 port : 51111 FULL_DUPLEX socket=13 UDP Protocol BS IP address Default identification port Port open in TX and RX "end of display 8.3.4.6 Role and setting of the BS signalling and phone servers The role of the signalling server is to exchange the following information in TCP: Base station operating parameters Communications management The role of the Phone server is to exchange the following information in TCP: Phone in the communications The two ports are made known to the server (NeTIS-N) using a download of the equipment database from the network management terminal. Port configuration on the network management terminal side: In NeTIS MAINTENANCE GUIDE – Version 1.1 94/139 8.3.5 DECLARATION OF THE NETIS-B ADDRESSES ON THE TETRA CS SIDE The SWITCH has a view of all the BSs that are part of the network via their IP address configured as shown below. When a configuration request for a BS is received, the SWITCH can load its configuration using the BS IP address. This address is also used to route phone and network communications. In NeTIS MAINTENANCE GUIDE – Version 1.1 95/139 IP-TCP: All Signalling and Phone exchanges use TCP/IP IP-UDP: All Signalling exchanges use TCP/IP All the Phone exchanges use UDP/IP NeTIS MAINTENANCE GUIDE – Version 1.1 96/139 8.3.6 SWITCH SIGNALLING AND PHONE PORT These SWITCH CPU ports and addresses will be used by the DISPATCHING. The Operator Stations must know the CPU IP (Signalling) address and the associated Signalling Port. As well as the phone port used by the SUPIP board. The SUPIP IP address is not used by the operator stations because phone is broadcast directly onto the IP network (UDP protocol) whereas for signalling both the TCP and UDP protocols are used. The SWITCH is configured by a download from the equipment database from the network management terminal. 8.3.7 SECONDARY NETWORK MANAGEMENT TERMINAL 8.3.7.1 General A network always has a primary network management terminal connected using an RS232 link to the NeTIS-N. You can add secondary network management terminal connected using IP to the main network management terminal . The rights of the secondary network management terminal are limited to network monitoring and to the ticket history (Logging) and you cannot load configurations to the NeTIS-N from it. NeTIS MAINTENANCE GUIDE – Version 1.1 97/139 NeTIS MAINTENANCE GUIDE – Version 1.1 98/139 8.3.7.2 Secondary network management terminal installation Retrieve the TetraCs directory from the primary network management terminal and paste it under the C: root of the new PC. Create an application short cut and in the "Target" field of the tetraCs properties add the word "secondary" as shown below: NeTIS MAINTENANCE GUIDE – Version 1.1 99/139 Launch the application 8.3.7.3 Configuring the main network management terminal The main console is considered to be a server to which the secondary network management terminal will connect. To do this, just declare a port for exchanges between consoles. The server listens on the port defined below. NeTIS MAINTENANCE GUIDE – Version 1.1 100/139
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 30 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:f968492f-8916-11e5-0000-74cd4aa41b7e Producer : GPL Ghostscript 9.10 Keywords : () Modify Date : 2015:11:09 09:25:39+01:00 Create Date : 2015:11:09 09:25:39+01:00 Creator Tool : PDFCreator Version 1.7.2 Document ID : uuid:f968492f-8916-11e5-0000-74cd4aa41b7e Format : application/pdf Title : netis B maintenance guide V1.1.pdf Creator : PCD Description : () Author : PCD Subject :EXIF Metadata provided by EXIF.tools