Elpas Solutions 5-PIR00433 CURTAIN PIR DETECTOR User Manual

Elpas Solutions Ltd. CURTAIN PIR DETECTOR

User Manual

Elpas Curtain PIR Detector P/N: 5-PIR00433 Installation Guide   www.elpas.com Page 1 of 8 V3/April 2013  Introduction This installation guide provides basic instructions for common Curtain PIR Detector installation scenarios. CAUTION! It is important that you read, understand, and follow the instructions in this document. If you have questions, call your local Elpas support representative. Product Description The Elpas Curtain PIR Detector is a battery operated; wireless curtain type PIR for protecting interior doors, walls, ceilings, windows and skylights as well as glass displays in residential,commercial and light industrial environments designed for use in Elpas Safety, Security and Visibility systems The  detector  provides  horizontal  or  vertical  curtain-shape,  passive–infrared perimeter coverage  up  to  6m  x  1m  (20ft  x 3.5ft)  and additionally can also be used as an internal invisible barrier to detect movement between two adjoining areas. The Curtain PIR Detector is engineered to continuously measure the ambient temperature of all objects within its field of view. Any rapid or differential change in temperature triggers the detector to transmit identifiable coded alarm RF messages which can be used to alert security personal of a possible intruder in the protected area.  To  ensure  maximum  security  reliability,  the  detector  supports  remote  supervision  to  protect  against  unauthorized  tampering, unapproved removal or of a dead  battery condition.  Small in  size and  weight, Curtain PIR  Detector  is easily fastened to  walls or ceilings and delivers three years of dependable service between battery changes. Coverage Patterns & Mounting Alternatives  Wall-Mount Curtain 2.4m Ceiling-Mount Curtain  Overhead Curtain Thissideup Curtain / Pet Alley OPTION A OPTION BDETECTIONCURTAIN CLIP MCW on Internal Doorframe    Preliminary
Elpas Curtain PIR Detector – Installation Guide    www.elpas.com Page 2 of 8 V3/April 2013    Tamper Switch The PIR Detector contains two spring loaded tamper switch that when pressed, generates a ‘State’ message that is useful for registering the detector in the host Elpas RTLS application. (Refer to the Eiris Configuration Guide for enrolling transmitter IDs.) Once registered, the tamper switch can also be used as an input trigger for a  device  supervision  tamper  alert  indicating  non-authorized  attempts  to remove the device’s cover. Power The PIR Detector derives its power from one CR2430 type lithium battery (factory supplied). IMPORTANT: The Wireless Input Module as well as all the input devices to be monitored should be powered down when wiring in order to prevent accidental shorts/spikes to cause damage to any of the devices. Supported Event Transmissions The Magnetic Contact Transmitter can transmit state changes from up to two dry contact inputs (as a button press event message) to the host RTLS server.   Input 1 – Button 1 Event   Input 2 – Button 2 Event The input module can also transmit a state change from the tamper switch  (as  a  motion  event  message)  indicating  a  non-authorized attempt to remove the module’s cover.   Tamper Switch – Motion Event Note: Whenever  a  state  change  is  detected  the  input  module  automatically transmits 4 RF event messages 400ms apart with each transmission about 2ms in duration). FRONTTAMPERSWITCHSENSORRANGESELECTJUMPER3 VOLTLITHIUMBATTERYBACKTAMPERSWITCH(OPTIONAL)RFMODULELEDS Status Indicator The  Magnetic  Contact  Transmitter  has  a  Red  Status  LED  that flashes once/second signaling either a low voltage condition or that the device is transmitting. Lithium Battery Installation (supplied with device) Before inserting  the  CR2430  type  lithium  battery  into  the  module’s battery  holder,  confirm  that  the  holes  of  the  battery  Isolator  are aligned with the contact pins. Then ensure that the positive (+) side of the battery faces the PCB.  IMPORTANT:  Inserting  the  1/2AA  battery  improperly  into  the battery clip may cause damage to the Wireless Input Module.  Product Specifications Signaling Technologies RF (433MHz) Transmission Rate Every 60 seconds Device Inputs 1 analog dry contacts and one reed switch Supervised Events Low Battery, Tamper Power Source 3.6V/1.2Ah Lithium Battery, LiSOCl2   size 1/2 AA Average Battery Life Approximately 3 years LED Indicator Low Battery, Device Transmission Badge ID Unique, factory-programmed ID Construction White polycarbonate plastic Dimensions (H x W x D) 81 x 22 x 23.5 mm (3-3/16 x 7/8 x 15/16 in.) Weight Reed Switch (excluding battery): 34 grams (1.2 ounces)     Magnet: 13 grams (0.45 ounces) Operating Environment Temp: 0°C to 49°C (32°F to 120°F)     Humidity: 90% non-condensing Remote Management Eiris 4.8 (or higher)     Elpas Configurator 4.8 (or higher)     ELC Programmer V2.0 Standards IC, FCC & CE compliant Warranty 1 year limited warranty (excluding battery) Product offerings and specifications are subject to change without notice.   Not all products include all features Preliminary
Elpas Curtain PIR Detector – Installation Guide    www.elpas.com Page 3 of 8 V3/April 2013   Installation Guidelines BREAK-AWAYSEGMENTATTENTION: The back tamperswitch  becomes  functionalonly  when  the  break-awaysegment  is  secured  to  thewall with a screw.INSERT SCREW TOSECURE COVERWITH BASE43POSITION THEPCB IN ITSPLACE IN THEBASE1DRILL TWO HOLESIN THE MOUNTINGSURFACE ANDSECURE BASE WITH TWO SCREWS 2FOR BACK TAMPER(OPTIONAL), DRILLTWO HOLESAND SECUREWITH TWO SCREW Figure 9. Surface Mounting  Notes: 1 ) After  mounting,  be  sure  that  no  gaps  remain  in  the  detector housing. For example, in the area around the screw holes. 2)  Remove  the  battery  using  your  fingers,  and  not  with  a screwdriver.  Bracket Mounting Note: When mounting using the bracket, the back tamper is not functional. Preliminary
Elpas Curtain PIR Detector – Installation Guide    www.elpas.com Page 4 of 8 V3/April 2013  DRILL TWO7 mm (1/4“)HOLESAT THEMARKED SPOTS  NOTE: THE BRACKET PROVIDES TWO MOUNTING OPTIONSFOR OPTIMUM ANGLE COVERAGE .   USE THESE TWO HOLES TO INCREASE     THE COVERAGE RANGE BY 5  USE THESE TWO HOLES TO INCREASE THE      COVERAGE RANGE BY 10DRILL TWO HOLES IN THEMOUNTINGSURFACE1SECUREBRACKETWITH TWOSCREWS2***   Preliminary
Elpas Curtain PIR Detector – Installation Guide    www.elpas.com Page 5 of 8 V3/April 2013  PLACE THELOCKING PLATEOVER THE TWOPINS2SECURE THELOCKINGPLATE BYPRESSINGDOWNWARD3LOCKINGPLATEPLACE THEBASE SLOTSOVER THETWOBRACKETPINS1 Figure 12. Securing Locking Plate to Base  POSITION THEPCB CORRECTLYIN THE BASE1INSERT SCREW TOSECURE COVERWITH BASE2 Figure 13. Mounting Cover to Base  Note: The CLIP MCW can be mounted on either side of a window.  Figure 14. Mounting on Both Sides of a Window Preliminary
Elpas Curtain PIR Detector – Installation Guide    www.elpas.com Page 6 of 8 V3/April 2013   Setting the Coverage Range A 4-pin jumper is used to select 3 ranges, according to the type of installation, for the curtain beams (see Figures 7 and 15). Short range -approx.2 m (6 ft) Medium range -approx.4 m (12 ft) Long range -approx.6 m (18 ft) Figure 15. Range Jumper Settings Short Range Medium Range Long Range Figure 16. Range Setting Diagram The purpose of the range setting is to ensure optimal signal processing and high immunity against false alarms. Mount the range jumper in the desired position and make sure that the protected area is within the selected coverage range (see figure 16). Carry out a walk test (refer to Para. 3.5) to verify proper performance.  Walk Testing A  Mount the cover and tighten the screw. Wait for the detector to stabilize (the LED stops flashing approx. two minutes after the cover is closed .)  B. Walk slowly across the far end of the curtain pattern (in opposite directions). The LED indicator lights for approx. 3 seconds whenever you enter or exit a curtain beam . Important: Perform walk test at least once a week to assure proper function of the detector. Note: After closing the cover the detector enters a 15 minute walk test mode. In this mode the LED will flash each time a detection occurs, regardless of LED jumper settings, and the detector will transmit on the occurrence of each detection event.  Preliminary
Elpas Curtain PIR Detector – Installation Guide   Page 7 of 8 V3/April 2013  W.E.E.E. Product Recycling Declaration For  information regarding the recycling  of this product  you must contact the  company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste - Directive 2002/96/EC Waste Electrical and Electronic Equipment.     EU Declaration of Conformity This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC FCC & IC Compliance Standards This  device  (FCC  ID#:  O4X5-PIR00433  and  IC  ID#:1467G-5PIR00433)  complies  with F CC  Rules  Part 15  and  with Industry  Canada  license -exempt RSS  standard(s).  Operation  is  subject  to  two  conditions:  (1)  This  device may  not  cause  harmful  interference,  and  (2)  this  device  must  accept  any interference that may be received or t hat may cause undesired operation. For Industry  Canada: Le présent appareil est conforme aux  CNR d'Industrie Canada  applicables  aux  appareils  radio  exempts  de  licence.  L'exploitation est  autorisée  aux  deux  conditions  suivantes  :  (1)  l'appareil  ne  doit  pas produire  de  brouillage,  et  (2)  l'utilisateur  de  l'appareil  doit  accepter  tout brouillage  radioélectrique  subi,  même  si  le  brouillage  est  susceptible  d'en compromettre le fonctionnement. Note:  This  equipment  has  been  tested  and  found  to  comply  with the  li mi ts for  a  Class  B  digital  device,  pursuant  to  part  15  of  the  FCC  Rules.  These limits  are  designed  to  provide  reasonable  protection  against  har mful interference  in  a  residential  installation.  This  equipment  generates;  uses and  can  radiate  radio  frequency  energy  and,  if  not  installed  and  used  in accordance  with  the  instructions,  may  cause  harmful  interference  to  radio communications.   However,  there  is  no  guarantee  that  interference  will  not  occur  in  a particular installation. If  this  equipment  does  cause  harmful  interference  to  radio  or  television reception,  which  can  be  determined  by  turning  the  equipment  off  and  on,  the user  is  encouraged  to  try  to  correct  the  interference  by  one  or  more  of  the following measures:    Reorient or relocate the receiving antenna.    Increase the separation between the equipment and receiver.    Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to which the receiver is connected.    Consult the dealer or an experienced radio/TV technician for help  Changes  or  modifications  to  this  equipment  not  expressly  approved  by  the par t y   r e spon si ble   for   co mp l ian ce   ( E l pas   Sol u ti on s   Lt d . )  coul d   v o i d  th e  u s e r ’s authority to operate the equipment. This  equipment  complies  with  FCC  and  IC  RF  radiation  exposure  limi ts  set forth for an uncontrolled environment. Company Contact Elpas, Inc. Westford, Massachusetts (USA)  Tel: 1-800-223-0020  Product Warranty E l p a s   Sol u t i on s,   L t d .   (t he  C o m p an y ),   a n d   i t s  a f f i l i at es,   w a r r a n t s  it s   pr od uc t s  ( h e r e i n a f te r   ref e r r ed   t o   as   "t h e   Pr o d uc t ”)   to   be  free  of   defect s  in  m aterial s  and  workman shi p  und er  normal  op e r a t in g   co nd i t io n s   an d   u se  f or   a   p e r i od   o f   one  ye ar   f r o m   t h e   dat e   of   sh i pm e n t   by  El pa s.   T h e   Com p an y ’s  o b l iga t io n s   s h a l l   b e   l im ited  wi thi n  the  warr ant y p eri od, at  it s  opti on, to  repai r  or to repla ce  the de fectiv e Product  or an y  defecti ve c om ponent  or part t hereof.  To  ex er cise  thi s  warra nty,  the pr od uct  must  be  retu rne d  to th e m a nuf acturer  freig ht prepaid  and insured.  This  warrant y  doe s  not  ap pl y  to r epair s  or  repl acem ent  caused  by i mprop er  inst allat ion,  Pro duct mi suse,  fail ur e  to follo w  instal lation  or  op er at ing instruct ions,  alter at ion,  ab use,  ac ci de nt, tamperi ng, re pair  by a ny on e  other  than  El pas,  ex ternal  causes, a nd fail ure  to p erform re quired prev entiv e mai ntenanc e.  This  w arra nt y  also doe s not  apply  to  any  pr od uct s,  acce ssories,  or  attachm ent s  u sed  in  co nj un ct ion  with  t he  Pro duct,  incl uding  batt eries,  whi ch  shall  be  cov er ed  sol el y  b y  th ei r  o wn  warr antie s,   if   any.  El pas  shall   not  be  li able  for  any   dam ag e  or  lo ss whatsoev er,  wh et her  di rectly,  in dire ctly,  inci dental ly,  conseq uentiall y  or  oth er wi se,  result ing  from  a  mal functi on  of   the  Pro du ct  due  to  produc ts,  acces sori es,  or  attac hment s  of   ot her s,  includi ng batt eries,  used i n c onj uncti on  wit h t he Prod uct.  ELPAS  MAKES  NO  EXPRESS   W ARRANTIE S  EXCEPT   T HO SE  ST AT ED  IN  THIS  STATEMENT.   ELP AS  DI SC LAI MS  ALL  OTHER  WARRANTI ES,   EXP RESS   OR  IMP LIED,   I NCLUDING  W I TH O UT   L I M I TAT I O N   I M P LI E D   W A R R A N T IE S  O F  M E R C H A N T AB I LI T Y   A N D  F I TNE S S   F OR  A   P A R T IC UL A R  P U RP O SE .   E L P A S’ S   S O LE   RE S PO N S I B I LIT Y   F O R  W ARRANTY  C LAIMS  IS LIMITED  TO REPAI R  OR TO  RE PLACE AS  SET F ORTH IN T HIS STATEM ENT.  Elpas  shal l  hav e  no  liabi lity  f or  any  deat h,  personal   injury,  pro perty  dam ag e,  or  other  lo ss  wh et he r  di re ct ,  indirect,   incide nt al ,  consequ ential,   or  ot he rwi se,  based  on   a  clai m  that  the Produc t  failed  to  f unct ion.  Ho wev er,  if   El pa s  is  hel d  li abl e,  whet her  dir ectly  or  in di rectly,  for  any  loss  or  damag e  ari si ng  un de r  this  li mited  warra nt y  o r  ot her wi se,  regardl ess  of   cause  or origin,  t he  com pany' s  max imum  li abi lity  shall  be  limited  to  the  pur ch ase  pri ce  of   the  Product,   which  shall  b e  f ixed  as  liquid at ed  dam ages  and  not  as  a  penal ty,  and  shal l  be  the  com plet e and ex cl usi ve l iabili ty of El pa s.  Elpas  sh all not, under  any  cir cum stanc es  what soever,  be  lia bl e  for  any inaccu ra cy,  error  of  jud gm ent ,  def ault,  or  negl igence  o f  Elpas,  it s  employ ees,  off icers,  agent s,  or  any  other  part y, or  of   the  purc haser  or  u ser,  ari si ng  f rom  any  assi st ance  or  c om municati on  of   any   kind  regar di ng  t he  c onf igurati on,  design,   i n st allat ion,  o r  creati on  of   securi ty  sy st em   i nv olv ing  the  Produc t,   th at  bei n g   t h e  r es po n s i b i l i t y   o f   t h e   p ur c ha se r   or  u s e r .   If   El p a s   i s  u n ab l e  t o   m a k e   s uc h   r e p ai r  o r  r epl a c e m ent ,  t h e   c o m pa ny ’s  e n t i r e   l iabili ty  shall   be  li mited  to  t he   co st   of   a reasona bl e  substi tut e pro duct. El pas s hall  not  be  responsi ble f or  any di sm ant ling,  insta ll at ion, rei nstall at ion,  pu rcha si ng,  ship pi ng,  insura nc e, or  any sim ilar c harges.  Elpas  shall   hav e  no  liabi lity  for  any  dam age s,  incl uding  wit hout  lim itation,  any  dire ct,  indir ect,  inci dental ,  spe ci al ,  or  co nseque nt ial  damage s,   exp en se s,   cost s,  pr of its,  lo st  sav ings  or  earnin gs,   or  other  d am ag es  ari si ng  out  of  t he use  of  t he  Product  or th e  remov al,  instal lation,  reinst al lation,  r epair  or  re pl ac em ent   of   th e  Pr oduct  or any  r el ate d  ev ents.  I n  the  ev ent  that  there i s any l iabil ity ag ai nst  Elpas,  such li abili ty  shall  be  limi ted to t he  purc hase  pri ce of  the Product  whi ch  amount  shall  b e  fixed  as liq ui dat ed dam ag es.  The  pu rchaser  and  u ser  under sta nd  that  thi s  Pr od uct  may  be  com promi sed  or  circumv ented  by  i ntenti onal  act s;  t hat   the  Pr oduct  wil l  not  i n  al l  cases  pr ev ent  deat h,  pe rsonal   injury,  propert y  dama ge,  or  other loss  result ing from  burglar y, ro bbery, fi re  or ot her  causes;  and  th at  the  Pro duct  will  not  in  all  c ases  prov ide  adequat e  war ni ng  or  pr otecti on.  The  purchaser  and user  al so  unde rst and  that   a  p roperl y  ins tall ed  and  m ai nt ai ne d  alarm   may  r educ e  t he  risk  of   ev ents  such  a s  burglary,  ro bbery,  and  f ire  wit hout  warni ng,  but  it  i s  n ot  insura nc e  or  a guarant ee th at su ch  ev ent s  wil l not  occ ur  or t hat  ther e  wil l be  no  death,  perso nal  injur y, prop ert y  damag e,  or  other  loss as  a  re sult  of  such ev ents.  By  purchasi ng  the  Prod uct ,  th e  purcha ser  an d  user  shall   defen d,   in dem ni fy  and  hold  El pas,  its  off icers,  direct or s,  af fili at es ,  subsi di aries,  agent s,  se rvant s,  empl oy ee s,   and  authori zed  repres entativ es  harmless  from  and  ag ai nst   any  and  all  claims, sui ts,  costs, dam ages,  and  ju dgment s  incurred,  clai med,  or  su st ained  wheth er  f or  deat h,  p er son al   inj ury,   pr op ert y  damag e, or  ot her wise,  beca use  of   or  in  any  way  rel ated  to  th e  conf igurati on,  desi gn,   in stal lation,  or  creati on  of   a  sec uri ty   system   inv olv ing  the  P roduct,  and  the  use,  sale,   di stri bution,  and i n s t a l lat i o n   of   t h e   Pr od uc t ,  in c l u di ng   p a y m e n t   o f   an y   an d  al l   at t or ney’ s   f ee s,   c ost s,   a n d   ex pe nse s  i n c ur re d   a s  a   re s u l t  of   a n y such ev ents.  The p urc haser  or u ser  should  fol low th e  Pr od uct  in st allation  and oper ation  instr uct ions  and  te st  the  Pr oduct  and the  enti re  syste m  at  least o nc e  each  week.  For v ar ious re aso ns, incl udi ng but  not  li mited  to  ch an ges  in  env ironment al   co ndi tion s,  electri c,  elect ronic,   or  electromag neti c  di srupti on s,  and  tamperi ng,  the  Pr od uct   may  not  perf orm  as  exp ect ed.  The  purch aser  and user a re  advi sed  to  take  all necessary pr ecautions  f or the pr ot ectio n a nd  safety of  per son s  and pr opert y.  This  st atem ent  prov ide s  ce rt ai n  leg al   ri ghts.  Other  right s  may  vary  by  st ate  or  count ry.   Unde r  cert ai n  cir cum stanc es,  som e  state s  or  count ries  may  not  al low  ex clusi on  or  lim itati on  of incide nt al or c onseq uenti al  damag es  or  i mpli ed  wa rrant ies, so t he a bov e excl usi ons m ay not  apply u nder t hose ci rc um st anc es an d i n t hose  st ate s  or co untrie s.  Preliminary
Elpas Curtain PIR Detector – Installation Guide    www.elpas.com Page 8 of 8 V3/April 2013  Elpas  reserv es t he  right  to  modif y  thi s  stat em ent at  any time,  in i ts  sole  discretion  wi thout  noti ce  to  an y  purchaser or  user .  Ho wever,  this  st at em ent  shall  not  be m odi fied  or v aried  ex cept by  Elpas  in  writi ng,  and  El pas  doe s  not  authorize  any  si ngle   indiv idual  to  act  on  it s  behalf   to  modi fy  or  v ary  thi s  statem ent.                                                                                 A ny  qu est i ons  abo ut  thi s st ateme nt  should  be directed t o  Elpas.  Preliminary

Navigation menu