Elster Solutions HHI01 VRT Hand Held Interrogator User Manual 2004234 AMCO HHI FCC Report R0 01

Elster Solutions, LLC VRT Hand Held Interrogator 2004234 AMCO HHI FCC Report R0 01

Manual revised

 Rhein Tech Laboratories, Inc.  Report #: 2004234 360 Herndon Parkway FCC ID: G8JHHI01 Suite 1400 Model #: 52808G505 Herndon, VA 20170 Standard: FCC Part 90 http://www.rheintech.com Date: January 24, 2005   .        Page 37 of 41     APPENDIX K: USER’S MANUAL  Please refer to the Operator’s Manual.
                                           Copyright © 2004 AMCO Automated Systems All Rights reserved Rev A UUUSSSEEERRR   GGGUUUIIIDDDEEE   TRACE®  TTrraaccee  IInntteerrrrooggaattoorr  VVRRTT      ((TTII  VVRRTT))  ffoorr      WWiinnddoowwss  CCEE  DDRRAAFFTT
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004  Introduction ...................................................... 4 System Requirements ..................................... 5 Hardware Requirements ........................................................... 5 Software Requirements ............................................................ 5 Warnings.................................................................................... 5 TI VRT CE Operation ................................................................. 5 Conventions ..................................................... 5 <Esc> ......................................................................................... 6 <Enter>....................................................................................... 6 <Up Arrow>,  <Down Arrow>.................................................... 6 <Tab> ......................................................................................... 6 Message Box <Yes> <NO> ....................................................... 6 TIV Screens ...................................................... 7 Login .......................................................................................... 7 Main (D)...................................................................................... 7 Route Selection (D) ................................................................... 7 Communications (D) ................................................................. 8 Data Entry .................................................................................. 8 Exit TI VRT CE ........................................................................... 8 Account Navigation and Data Entry............... 9 Navigation.................................................................................. 9 <Esc>..............................................................................................9 <Enter> .........................................................................................10 <Up Arrow>,  <Down Arrow>......................................................10 Jumps ...................................................................................... 10 Jump to the Previous Route.......................................................10 Jump to Beginning of Current Route.........................................10 Jump to End of Current Route ...................................................10 Jump to Next Unread Interrogation ...........................................10 Jump to Specified Sequence Number .......................................11 Jump to Next Unread Account in the Current Route................11 Jump to Next Route.....................................................................11
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 Searches .................................................................................. 11 Information Displays............................................................... 12 Help / Available Commands Display..........................................12 Route Selection Display..............................................................12 Route Summary Display .............................................................13 Configuration Display .................................................................13 Display VRT Requests Details....................................................13 Trouble Code Display..................................................................14 Messages Display........................................................................15 Error Log Display ........................................................................15 Data Entry operations............................................................. 16 Manual Index Read......................................................................16 Clear Index Read .........................................................................17 Force Unattempted Account ......................................................17 Adding a Trouble Code ...............................................................17 Adding / Editing a Text Message................................................18 Setting the Re-sequence Flag ....................................................19 Single RF Index Read..................................................................20 Multiple Parameter RF Read.......................................................21 Single History / TOU RF Read ....................................................22 General Index RF Read ...............................................................22 TI VRT CE Communication with Route Manager VRT .................................................. 23 Establishing communications................................................ 23 Uploading Routes from RM VRT to TI VRT(CE) .................... 25 Downloading data From TI VRT(CE) to RM VRT ................... 26 Removing Route From TI VRT (CE) ....................................... 26 Updating Handheld files ......................................................... 26 Hot keys .......................................................... 28 Troubleshooting............................................. 29
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 Introduction   Copyright © 2004 AMCO Automated Systems. All Rights Reserved  The contents of this document are the property of AMCO Automated Systems and are copyrighted. All rights reserved. Any reproduction, in whole or in part, is strictly prohibited. For additional copies of this document, please contact:  Customer Service AMCO Automated Systems 107 Erskine Lane Scott Depot, WV  25560 Phone: 304-757-3300   Fax: 304-757-3388 http://www.amcoas.com  The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. AMCO Automated Systems reserves the right to make changes without prior notice. This document is not covered by any warranty either expressed or implied. Any correction, comments or additions to the contents of this document should be directed to AMCO Automated Systems at the above address.  TRACE, Universal RF Interface (RF), Mini Mobile Interrogator (MMI) and ReadIt are also trademarks of AMCO Automated Systems. All rights reserved.  MS-DOS, MS Windows, MS Windows CE and IBM are registered trademarks of their respective owners.  FCC Compliance The VRT HAND HELD Interrogator (HHI) has been type accepted by the Federal Communications Commission under Part 90.  Transmitter licensing is required by the FCC.  The VRT HAND HELD Interrogator (HHI) transmitter is currently licensed by the FCC to operate at 450-460 MHz.  FCC ID is G8JHHI01.  Changes or modifications to this equipment not expressly approved by AMCO Automated Systems could void the user's authority to operate this equipment.   This device complies with Part 15 of the FCC rules.  Operation is subject to the condition that this device does not cause harmful interference.  The TRACE transponder is governed by FCC Part 15 and requires no licensing.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 System Requirements Hardware Requirements DAP 5240 or 5240X with AMCOAS HHI RF card Radix FW-500 with AMCOAS HHI RF card Software Requirements  Windows CE 3.0 or later Route Manager VRT  Warnings Do not attempt to modify or edit any of the subsidiary tables or files outside of the TI VRT (CE) / RM VRT environment without prior authorization by AMCO Automated Systems technical service personnel. Unauthorized manipulation of these files may void your software service agreements.  Uploading from Route Manager VRT (RM VRT) will overwrite Route/Account information on the Hand Held. It is the User’s responsibility to download any data prior to uploading.  RF EXPOSURE  The antenna used for this transmitter must be installed to provide a separation distance of at least 24 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter.  TI VRT CE Operation TI VRT for CE is supported on two different hardware platforms: the DAP 5240 and the Radix FW-500. While most operations are identical some are platform specific. Features for the DAP 5240 are marked D and those for Radix are marked R.  The screen shots shown in various illustrations may vary slightly from your Handheld’s display.   Conventions  All user interactions are via the Handheld’s keyboard. TI VRT CE responds to the keystrokes independent of platform. All letters are assumed to be upper case. Function keys F1 – F4 are also used.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 <Esc> o  Cancels operations  o  Exits screens  <Enter> o  In menus/list boxes selects item o  In editable field submits entry o  With Automove on, submits entry and moves to next Account. o  In Details list box (History & TOU) initiates single interrogation of highlighted item <Up Arrow>,  <Down Arrow> These keys are used to navigate between accounts within the current Route. When either the first or last account is reached an audible warning will sound and the display will remain on the current account. <Tab>   key is used to navigate between fields within the current screen (messages, search, etc.).  Message Box <Yes> <NO> The response to the message box can be:  o  Touching the button <Yes> or <No> o  Clicking letter “Y” or “N” on the keyboard o  Moving to the desired button by using left/right arrow keys and pressing Enter when the button is highlighted.    D at the bottom (in Lower right corner) of the data entry screen indicates VRT request details are available. The number after the D indicates the number of requests.  AM-off/on at the bottom (in Lower right corner) of the data entry screen indicates AutoMove is enabled or disabled.  M at the bottom (in Lower right corner) of the data entry screen indicates messages are available.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 TIV Screens Login The Login screen is not currently operational. Main (D)   The main screen allows the selection of the following modes: o  Route Selection / Data Entry o  Communication (between RMVRT and device) Route Selection (D)   If Route Selection is selected, the list of routes loaded in the device is displayed. To view/update Account information for the chosen route highlight the route and press “Enter”.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 Communications (D) The Communications mode is used to exchange data files and other information with Route Manager VRT. This selection, opens the specified communications port, displays the communications screen and initiates polling for incoming messages from RM VRT.     Data Entry     Exit TI VRT CE Pressing the <ESC> in the Main Menu will pop up a confirmation box. Use the <TAB>, <Left Arrow>, or <Right Arrow> keys to select the response. •  Press “YES” button or click the “Y” key or click the <Enter> key when the button is highlighted to accept the selection. •  Press <No> button or click the “N” key or click the <Enter> key when the button is highlighted to Cancel.  Rt: Route ID Sq: Sequence Number Ad: Address Nm: Customer Name Xp: Transponder Mn: Meter Number Ac: Account Number TT: Transponder Type MT: Meter Type PC: Premise Code SV: Survey Code LC: Location Code IC: Instruction Code RD: Index Read TC: Trouble Code  ST: Account Status Æ : Direction of Data Entry  D    VRT Details available AM-off/on AutoMove enabled M    Messages available
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004  Account Navigation and Data Entry  Navigation All user interactions are via the handheld’s keyboard or the Touch Screen using a stylus. TI VRT (CE) responds to the keystrokes independent of platform. All letters are assumed to be upper case. Function keys F1 – F4 are also used.   . <Esc> o  Cancels operations.  o Exits screens.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 <Enter> o  In menus/list boxes selects item. o  In editable field submits entry. o  With Automove on, submits entry and moves to next Account. o  In Details list box (History & TOU) initiates single interrogation of highlighted item.  <Up Arrow>,  <Down Arrow> These keys are used to navigate between accounts within the current Route. When either the first or last account is reached an audible warning will sound and the display will remain on the current account.  Jumps Jumps are moving from the current account in the current route to various other accounts and routes. Pressing the appropriate hot key activates jumps. The X (Cancel Jump) Hot key is used to return to the account displayed just prior to the jump except as noted.  Jump to the Previous Route  Hot Key: A This is a jump to the first account in the previous route. X  has no effect. If pressed on the first route the bounds beep sounds and the display remains on the current account.  Jump to Beginning of Current Route Hot Key: B  This is a jump to the first account in the current route.   X Jumps to record displayed prior to the jump. If pressed at the beginning of the route the bounds beep sounds and the display remains on the current account.  Jump to End of Current Route Hot Key: E This is a jump to the Last account in the Current route. X Jumps to record displayed prior to the jump. If pressed at the end of the route the bounds beep sounds.   Jump to Next Unread Interrogation Hot Key: I This is a jump to the next account in the Current route that has unread interrogation. The unread interrogation can be index read or any VRT request.  If there are VRT requests for the account the
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 letter “D” is displayed on the right side at the bottom of the screen.  To view VRT requests press “D”. X Jumps to record displayed prior to the jump. If pressed at the end of the route the bounds beep sounds.  Jump to Specified Sequence Number Hot Key: J  This is a jump to a specified sequence number in the current route. After pressing the J hot key an entry window will pop up. Type the sequence number in the box and press the <ENTER> key twice (Once to accept the number and once to press the OK button). X Jumps to record displayed prior to the jump.  Jump to Next Unread Account in the Current Route Hot Key: U This is a jump to a next account with index read –2 and trouble code 0 in the current route.  X Jumps to record displayed prior to the jump.  Jump to Next Route Hot Key: Z  This is a jump to next route. X has no effect.  Searches Searches allow the user to jump to any specified account in the current Route. Currently the following searches are available: o Account number o Transponder number o Meter number o Customer Name o Customer address o Premise code o  Specific trouble code o  Any trouble code  Hot Key: H search menu To perform a search: •  Press the H key to bring up the search type display •  Select the type of search to perform using the <Up Arrow/Down Arrow> keys  •  Use the <> key (Tab) to
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 move between fields on the screen •  Select whether exact match is wanted or the search performed by partially submitted information is preferred (except for search for accounts with trouble code). •  Fill the field with the desired information (except for search for accounts with any trouble code). •  Press Search to begin the defined search. •  The results list present the following information  Account Number  Address •  a. Select an item from the results list and press the <ENTER> key or click with the stylus to jump to the account.  Searches with only 1 account returned will jump directly to that account. •  Pressing the <ESC> key cancels the search. •  Press button <Clear> to clear the search and to start over.  X Jumps to record displayed prior to the jump.  Information Displays Several informational displays are available to the user from the data entry screen. Most of these take the form of a Pop-Up List Box over the Data Entry screen. As usual the <ESC> key acts as the Cancel button to exit back to Account Data Entry screen.  Help / Available Commands Display Hot Key: F1  X has no effect. <Up Arrow> and <Down Arrow> keys select the desired hot key from the list. <ENTER> initiates the command as if the hot key had been pressed. <ESC> closes the popup. Picture goes here  Route Selection Display Hot Key: F2 X has no effect <Up Arrow> and <Down Arrow> keys select the desired Route from the list. <Enter> jumps to the first account in the selected route. <ESC> closes the popup.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004    Route Summary Display Hot Key: F3  X has no effect. Use <Up Arrow> and <Down Arrow> to move within the screen. <ESC> closes the popup. Picture goes here  Configuration Display Hot Key: F4  X has no effect. Use <Up Arrow> and <Down Arrow> to move within the screen. Tab moves the cursor from the Meter Reader configuration items to all the configuration items. <ESC> closes the popup. Picture goes here  Display VRT Requests Details Hot Key: D  - displays a pop-up list of all requests.  If  “D” appears in the lower left corner of the data entry display, the account contains one or more History and/or TOU requests.  <Esc> closes the pop-up.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004    Trouble Code Display Hot Key: T  <ESC> closes the popup.  Trouble codes are used to indicate problems with obtaining readings.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004   Messages Display Hot Key: M   <ESC> closes the popup.  A 19-character message, 3 user messages of 20 characters each can be entered for each account or edited using this option.   These messages can be sent from RM VRT.  If  “M” appears in the lower left corner of the data entry display, the account contains one or more messages. If “!!” follow the message then one of the messages contain alarm.  A free form note pad is also available here. A free form note pad is NOT account specific but is common to all accounts and all routes.    It can be configured in RM VRT not to allow to edit messages.  An audible alarm can be set in RM VRT if one of the messages exists; if sound is disable a message box will pop up with the warning.   Error Log Display Hot Key: O   <ESC> closes the popup. Use <Up Arrow> and <Down Arrow> to move within the screen. <ESC> closes the popup.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004   Data Entry operations Index reads can be entered manually, singly by RF, as part of a multiple parameter read of Index, History and TOU.    History and TOU reads can be performed either singly or as part of a multiple parameter read of Index, History and TOU.   Manual Index Read  Enter digits 0  - 9 and press the <ENTER> key. The direction of manually reading a meter is shown by the arrow by the reading and is dependant on the meter type.    The number entered will be checked against: •  The number of dials as reported in Route Manager for the account.  This option can be turned off/on in RM VRT. • Upper Limit and Lower Limit for the account as reported in RM VRT.  This option can be turned off/on in RM VRT. • Previous read for the account as reported in RM VRT. A Zero (0) uploaded for the value to check turns this option off.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 If the entered index read fails the verification above the message will pop up asking if it needs to be recorded or cancelled.  If the Automove option is ON, the display will show the next account in the route. If the account is the last one in the current route an audible alert will sound.  Clear Index Read Hot Key: C  X has no effect After pressing the “C” key the reading is cleared and the cursor is positioned in the index read field waiting for the entry to overwrite the previous reading.  Force Unattempted Account Hot Key: F  X has no effect If the account had manual reading, then after pressing the “F” key the reading and trouble code are cleared, the status of the account is set to unattempted.   Adding a Trouble Code Hot Key: T X has no effect   Trouble codes are used to indicate problems with obtaining readings. A code can be entered with or without entering a reading.  <Up Arrow> and <Down Arrow> keys select the desired Trouble code from the list. <ENTER> updates the account with the selected Trouble code. <ESC> closes the popup.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004    Adding / Editing a Text Message Hot Key: M   X has no effect  A 19-character message, 3 user messages of 20 characters each can be entered for each account or edited using this option. These messages can be sent from RM VRT.   A free form note pad is also available here. Entry into the note pad causes the account number data and time to be added to any already existing text. This option is NOT account specific but is common to all accounts and routes.  <TAB> moves the cursor to the next message for editing. <ESC> Asks if the changes to messages to be saved.  Pressing button <YES> or clicking key <Y> will save the changes and close popup; pressing button <NO> or clicking key <N> quit the popup without saving changes to messages.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004    Setting the Re-sequence Flag Hot Key: Q X has no effect   If account(s) is out of sequence in a route, setting the Re-sequence flag marks the route for re-sequencing by date time stamp during reading the route.  The re-sequencing is going to be done in the Billing system after uploading to RM VRT.  The message box will pop-up to verify if re-sequencing is desired.  Answer yes or no by: o  Touching the button <Yes> or <No> o  Clicking letter “Y” or “N” on the keyboard o  Moving to the desired button by using left/right arrow keys and pressing Enter when the button is highlighted.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004    Single RF Index Read Hot Key: S  X has no effect  After pressing the “S” key an RF communications window will open and RF interrogation will start. The user will be able to watch commands issued and replies returned from the target transponder. Once the interrogation is completed the communications window will close and the database will be updated.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004  Notes:  A success/fail sound will alert the meter reader about the result of reading if the option “Enable sound “ is ON.    If the Automove option is ON and the reading was successful, the display will show the next account in the route. If the account is the last one in the current route an audible alert will sound.   Multiple Parameter RF Read Hot Key: R   X has no effect  After pressing the “R” key an RF communications window will open and RF interrogation will start for index read and for all the VRT commands in the account. The user will be able to watch commands issued and replies returned from the target transponder. Once all the interrogations are completed the communications window will close and the database will be updated.    Notes:  A success/fail sound will alert the meter reader about the result of reading if the option “Enable sound “ is ON.    If the Automove option is ON and all the reading were successful, the display will show the next account in the route. If the account is the last one in the current route an audible alert will sound.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004  The progress bar shows the completion status of Multi-parameter reads.   Single History / TOU RF Read If a “D” appears in the lower left corner of the data entry display, the account contains one or more History and or TOU requests.  Press the “D” key to display a pop-up list of all requests. Use the Up / Down arrow keys to select the History/TOU request to read. Press the <ENTER> key to start the interrogation.   An RF communications window will open and RF interrogation will start. The user will be able to watch commands issued and replies returned from the target transponder. Once the interrogation is completed the communications window will close and the database will be updated. The pop-up list will be updated with the information obtained from the transponder.  If a valid index read does not exist, one will be added to any single History requests. A new index read will be added to any Single TOU request. Pressing the <ESC> key will close the Pop-Up display.   General Index RF Read Hot Key: G   X has no effect
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 After pressing the “G” key the popup display will open. Enter the desired transponder number and press <ENTER>. An RF communications window will open and RF interrogation will start. The user will be able to watch commands issued and replies returned from the target transponder. When the interrogation is completed, the communications commands will be replaced with read results. Data is NOT added to the database.       TI VRT CE Communication with Route Manager VRT Establishing communications 1.  Using the Devices section of Route Manager VRT, select the desired Handheld from the Handheld Selection drop-down list. 2.  Ensure that the proper cable (null modem) is connected between the computers COM port(s) and the Handheld device’s cradle. 3.  Ensure that the Handheld device is turned on and properly seated in its cradle. 4.  Make sure the Handheld is in communications mode. (F3 from the Main Menu) 5. Click the Connect button in RM VRT.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004   Upon Successful connection: • The Connect button will display ‘Disconnect’  •  The Serial Number and Handheld Software Version will be displayed directly beneath the Disconnect button. •  The Handheld function buttons will be disabled. •  The Handheld Communication buttons will be enabled. •  If Routes exist in the Handheld they would be displayed in the “Routes in Handheld” display grid.
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004   Uploading Routes from RM VRT to TI VRT(CE) 1.  Follow the Connection steps outlined earlier. 2.  Ensure that the desired Route is assigned to the connected Handheld device. 3.  Highlight the desired route(s) in the Assigned Routes display grid. 4. Click the Send Route button to send the route to the Handheld Device. After the Route has been sent successfully to the Handheld device, the Routes in Handheld display grid will be updated to display the sent route and the Handheld will be automatically rebooted  (See Figure x – Route 123000) Note: Uploading Route(s) will overwrite any existing data on the hand held. It is the user’s responsibility to make sure all data is downloaded from the hand held PRIOR to uploading new routes
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 Downloading data From TI VRT(CE) to RM VRT 1.  Ensure that the Handheld is connected via the steps outlined earlier. 2.  Select the desired Route(s) to receive from the Routes in Handheld display grid. 3. Click the Receive Route Button to start the process. 4. Upon successful completion the Route Status will change to ‘Transferred’ and the Handheld will disconnect from the application. Removing Route From TI VRT (CE)  To Remove Routes From Hand Held after receive: 1.  Follow the Steps outlined earlier for Transferring and Connecting to the Handheld device 2.  Select the Remove Route(s) from device after received check box 3. Click the Receive Route(s) button  To Remove Routes from HH without receiving the Route from HH: 1. Follow the Steps outlined earlier for Connecting to the Handheld device. 2. Once connected, select the Route to remove from the Routes in Handheld display grid. 3. Click the Remove Route(s) from HH button. 4.  Click OK on the message box.    Updating Handheld files 1. Follow the Steps outlined earlier for Connecting to the Hand Held device. 2. Click the Update Handheld File button. You are presented with the Update Handheld Files form (see picture below) 3.  Select one of the two options: Update Handheld Files or Send a File. a.  Update Handheld Files – Select the check boxes for the files you wish to update and then click button “Send File(s)”, or b.  Send a File – Input or Browse to the name and location of a file to send to the Handheld and then click button “Send File(s)”
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 Hot keys Hot Keys Action A  Jump to previous route B  Jump to Beginning of current route C Clear Reading D Detail History / TOU for Current Account. Pressing  <Enter> key initiates RF interrogation for the selected item E  Jump to End of current route F  Set account as unattempted (only for manual read) G General Interrogation of the entered transponder. H  Search menu I  Jump to next unread Interrogation – Not Implemented in this release J Jump (by sequence) K  Unused L Lock – Not Implemented in this release M Message (Comments). Messages can be added or edited if allowed. N  Unused O  Error log P  Unused Q  Set the Re-Sequence flag for upload R RF Read Index and all VRT requests for current account S Single index read for current account T Trouble code.  Allows selection of trouble code for current account U  Jump to next Unread account V Verify (set from configuration table) – Not Implemented in this release Y Survey. Allows selection of survey code for current account Z  Jump to next route F1  Displays key list with description.  When an item is selected the choice is executed (if appropriate). F2  Route Selection / Load F3  Current Route Summary or Communication on the main screen F4  Configuration Settings
                                                                                                                             TRACE INTERROGATOR VRT (CE) OPERATIONS    Trace Interrogator VRT (CE) - User Guide AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004 Configuration               Local Host: Device’s IP address RM VRT Host: IP address of the computer with RM VRT installed  Transfer Type: Serial or Ethernet depending on the device. Do Survey: for the device used for survey functions (future release). 1500COM32525 137214

Navigation menu