Model Programming Choices
1F95-1291 7 Day 5+1+1 Day Non-Programmable
www.white-rodgers.com
www.emersonclimate.com
Big Blue Humidity Universal Thermostat
with Humidity/Dehumidity Control and
Automatic Heat/Cool Changeover Option
PART NO. 37-7313B
Replaces 37-7313A
1241
Single Stage, Multi-Stage, Heat Pump
Installation and Operating Instructions
APPLICATIONS
SPECIFICATIONS
1F95-1291 Humidity Control Touchscreen Thermostat
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
THERMOSTAT APPLICATION GUIDE
Thermostat
Configuration Options
Thermostat
Applications
Maximum
Stages
Heat/Cool
Single Stage 1
No Heat Pump (SS1)
Gas, Oil, Electric, Heat Only,
Cool Only or Heat/Cool
Systems, 2 or 3 wire Hydronic
Zone (Hot Water or Steam)
Systems, 24 Volt or Millivolt
1+1
Multi Stage 2
No Heat Pump (MS2) 2+2
Heat Pump 1
Single Stage Compressor
Heat Pump (HP1)
Single Stage Compressor
Heat Pump Systems - up to 2
Stages Aux./Emergency Heat
3+1
Heat Pump 2
Two Stage or Two
Compressor Heat Pump
(HP2)
Two Stage or Two Compressor
Heat Pump systems - up to 2
Stages Aux./Emergency Heat
4+2
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this prod-
uct may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to www.thermostat-recycle.org for loca-
tion to send the product containing mercury.
Index Page
Installation 2
Wiring Diagrams 3
Thermostat Quick Reference 5
Installer Configuration Menu 6
Operating Your Thermostat 10
Programming 12
Troubleshooting 15
Electrical Rating:
Battery Power .......................... mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire ......................... 20 to 30 VAC
Terminal Load ............................. 1.5A per terminal, 2.5A maximum all terminals combined
Setpoint Range ............................ 45 to 99°F (7 to 37°C)
Rated Differentials: Fast. Slow
Heat (Single Stage/Multi-Stage) ............ 0.6°F 1.5°F
Cool (Single Stage/Multi-Stage) ............ 1.2°F 1.7°F
Heat Pump ............................ 1.2°F 1.7°F
Emer Heat ............................ 0.6°F 1.7°F
Operating Ambient.......................... 32°F to +105°F (0 to +41°C)
Operating Humidity ......................... 90% non-condensing max.
Shipping Temperature Range ................. -40 to +150°F (-40 to +65°C)
Dimensions Thermostat...................... 4-9/16"H x 5-13/16"W x 1-3/16"D
Humidity Setpoint Range..................... 5 to 50%
Dehumidification Setpoint Range .............. 40 to 95%
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
2
Remove Old Thermostat
Before removing wires from old thermostat, mark wires for
terminal identification so the proper connections will be made
to the new thermostat.
Installing New Thermostat
1. Pull the thermostat body off the thermostat base. Forcing
or prying on the thermostat will cause damage to the unit.
2. Place base over hole in wall and mark mounting hole
locations on wall using base as a template.
3. Move base out of the way. Drill mounting holes. If you
are using existing mounting holes and the holes drilled
are too large and do not allow you to tighten base snugly,
use plastic screw anchors to secure the base.
4. Fasten base snugly to wall using mounting holes shown
in Figure 1 and two mounting screws. Leveling is for
appearance only and will not affect thermostat operation.
5. Connect wires to terminal block on base using appropriate
wiring schematic.
6. Push excess wire into wall and plug hole with a fire resis-
tant material (such as fiberglass insulation) to prevent
drafts from affecting thermostat operation.
7. Carefully line the thermostat up with the base and snap
into place.
Battery Location
2 "AA" alkaline batteries are included in the thermostat at the
factory with a battery tag to prevent power drainage. Remove
the battery tag to engage the batteries.
To replace batteries, set system to OFF, remove thermostat
from wall and install the batteries in the rear along the top
of the thermostat (see Figure 1). For best results, use a
premium brand "AA" alkaline battery such as Duracell® or
Energizer®. If the home is going to be unoccupied for an
extended period (over 3 months) and is displayed, the
batteries should be replaced before leaving.
Power Stealing Switches
The Power Stealing Switches (Fig. 1) should be left in the
"On" position for most systems. The information in the
following table details the thermostat power method and
switch options.
WARNING
!
Thermostat installation and all components of the
control system shall conform to Class II circuits per
the NEC code.
INSTALLATION
Figure 1 – Thermostat Base Multi-Stage 1F95-1291
2 "AA" Batteries
Power
Stealing
Switches
Stack
Power
Stealing
Switch
Mounting
Hole
Mounting
Hole
Place Level
across Mounting Ta bs
(for appearance only)
Place Level
across Mounting Ta bs
(for appearance only)
+
S
HM
-
W/E
6
DHM
Y2
O/B
L
Y
W2
Rear view of thermostat
Thermostat Power Method Switch Position/Description
Battery Powered, no 24
Volt system power available.
Switches "On", thermostat
runs on batteries.
Hardwired with Battery
Back-up, for 24 Volt systems
with common connection from
transformer to "C" terminal
on thermostat.
Switches "On", thermostat
runs on power directly from
transformer with battery back-
up.
*Battery Powered with
Power Stealing Assist,
for 24 Volt systems with no
common connection from
transformer to "C" terminal on
thermostat.
Switches "On", thermostat
runs on batteries and
supplemental power drawn
through the heat or cool circuit.
*Power Stealing Assist is very reliable to increase battery life,
but on a small number of heating or cooling systems with high
impedance electronic modules you may observe one of the
following conditions:
1. The furnace draft inducer motor may run with no call for
heat.
2. The furnace fan may turn on with no call for heat or may
not turn off.
3. The furnace may not turn off when the call for heat ends.
4. The air conditioner may not turn off when the call for cool
ends.
If the Power Stealing Assist method is not compatible with
your system, place the Power Stealing Switches to "Off". This
cancels Power Stealing Assist, operates the thermostat on
batteries and corrects the condition.
3
WIRING DIAGRAMS
Figure 2 – Single Stage or Multi-Stage System
(No Heat Pump) with Single Transformer
Single Stage 1
(SS1)
Multi Stage 2
(MS2)
System RC RH CY Y2 W/E W2 G O/B 6L
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Call for heat
Heat mode-1st
stage
Heat mode-2nd
stage
No output
24 volt
power for
cooling
24 volt
power for
heating
Cool mode-2nd
stage
24 volt
common
(optional
for system
operation,
required
for remote
sensor)
Call for cool No Output
Cool mode-1st
stage
Blower/Circulator fan
energized on a call
for cool or Fan On
(also energized in
heating if configured
for Electric Heat)
Installer
Configuration
Menu selects
“O” or “B” for
changeover
function. Set
to “O” terminal
energized in Cool
& Off mode. Set
to “B” terminal
energized in
Heat & mergency
mode
Power closed
connection for
SPDT 3-wire
zone valve
Fault or System
Malfunction
Indicator for
Heat Pumps
with “Lterminal
connection.
Original production
1F95-1291’s
do not have this
connection
Figure 3 – Heat Pump Systems
Heat Pump Connections
If you do not have a heat pump system, refer to figures 3 & 4.
Refer to equipment manufacturers’ instructions for specific system
wiring information.
You can configure the thermostat for use with the following heat pump
systems.
Single Stage and Multi-Stage Connections
Refer to equipment manufacturers’ instructions for specific system
wiring information.
This thermostat is designed to operate a single-transformer or two-
transformer system.
You can configure the thermostat for use with the following fossil fuel
systems:
Heat
Pump 1
(HP1)
Heat
Pump 2
(HP2)
System RC RH CY Y2 *W/E *W2 G O/B 6L
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
Heat mode-2nd
stage, Emergency
Mode-1st stage
*Note: Dual Fuel
option de-
energizes Heat
mode stage 1
(compressor)
when auxiliary
heat is energized
Heat mode-3rd
stage, Emergency
Mode-1st stage
*Note: Dual Fuel
option de-
energizes Heat
mode stages 1
and 2 (both
compressors)
when auxiliary
heat is energized
Heat mode-4th
stage, Emergency
Mode-2nd stage
*Note: Dual Fuel
option de-
energizes Heat
mode stages 1
and 2 (both
compressors)
when auxiliary
heat is energized
Heat mode-3rd
stage, Emergency
Mode-2nd stage
*Note: Dual Fuel
option de-
energizes Heat
mode stage 1
(compressor)
when auxiliary
heat is energized
24 volt
power for
cooling
24 volt
power for
heating
Heat mode-2nd
stage,
Cool mode-2nd
stage,
(Compressor)
No Output
24 volt
common
(optional
for system
operation,
required
for remote
sensor)
Heat mode-1st
stage,
Cool mode-1st
stage,
(Compressor)
Blower/Circulator fan
energized on a call
for cool or Fan On
(also energized in
heating if configured
for Electric Heat)
Installer
Configuration
Menu selects
“O” or “B” for
changeover
function. Set
to “O” terminal
energized in Cool
& Off mode. Set
to “B” terminal
energized in
Heat & mergency
mode
Power closed
connection for
SPDT 3-wire
zone valve
Fault or System
Malfunction
Indicator for
Heat Pumps
with “Lterminal
connection.
Original production
1F95-1291’s
do not have this
connection
COOLING
CLASS II
TRANSFORMER
HOT
24VAC
NEUTRAL
120VAC
HEATING
120VAC
*Dual fuel option, if selected turns off compressor(s) when Auxiliary stages energize.
SINGLE STAGE (SS 1) gas, oil or electric.
MULTI-STAGE (MS 2) gas, oil or electric.
After wiring, see INSTALLER CONFIGURATION section for proper
thermostat configuration.
HEAT PUMP TYPE 1 (HP 1). Single stage compressor system;
gas or electric backup.
HEAT PUMP TYPE 2 (HP 2). Multi-stage compressor or two
compressor system with gas or electric backup.
After wiring, see INSTALLER CONFIGURATION section for proper
thermostat configuration.
4
If you have a single stage compressor system see the dia-
gram below. A relay (customer provided) should be installed
as shown in Fig 7 to switch the fan speed to the next lower
speed on a call for dehumidification from the thermostat. The
reduction in air flow allows the coil to remove more humidity
from the air. The relay should be rated for blower motor load.
Since this configuration reduces the air flow in cooling, the
WIRING DIAGRAMS
anti-freeze-up control (White-Rodgers CAFC) or equivalent is
recommended. The CAFC prevents the air conditioning coil
from freezing due to low air flow, dirty filters, low refrigerant
pressure, etc. The CAFC snaps onto the suction line close to
the evaporator coil as possible and breaks the compressor
circuit when the suction line drops below 38 °F and re-make
the circuit at 46°F.
HOT
NEUTRAL 120 VAC
24 VAC
Relay
90-290Q
or equivalent
HOT
NEUTRAL 120 VAC
TRANSFORMER
R
HM
Humidifier
System
Figure 6 – Typical Wiring for 120V Humidifier System
HOT
NEUTRAL 120 VAC
TRANSFORMER
HM
24 VAC
Humidifier
System
R
Figure 7 – Typical Wiring for 24V Humidifier System
Dehumidification wiring without an electronically controlled variable speed blower system for
single stage compressor system only.
HM DHM
Humidification Te rminal,
Energizes on call for
heat if Humidity setpoint
is above room humidity.
Can also be used to
provide humidification
independent of a call for
heat and/or in cooling
mode if Automatic
Humidification is
selected in Configura-
tion Menu item #34
De-energizes on call for
Dehumidification to
lower the fan speed.
The DHM terminal is
only used on systems
with a compatible
dehumidification feature
that have the required
terminal connection on
the contol module or
have a relay installed to
lower the fan speed
+S-
Supply voltage
to remote
temperature
sensor
Remote
temperature
sensor signal
Supply voltage
to remote
temperature
sensor
Figure 4 – Humidity and Sensors
Relay
90-293Q
or equivalent
No
NC
“Heat Fan Output”
N
Dehum
Speed Fan
Med
DHM
N
Low
Normal High
“Cool Fan Output”
1
2
Normal Cool speed position (DHM energized)
Dehum speed mode (DHM de-energized)
1
2
Figure 5 – Typical Wiring for Dehumidifier System
5
Programming and Configuration Items
1 Displays and "Keypad Lockout" when in keypad
lockout mode.
Displays and "Temperature Limit" and "Keypad
Lockout" when limited range is activated and locked.
Displays only "Temperature Limit" when limited range
is activated.
2 Indicates period of day being programmed.
3
RUN SCHEDULE (run program) key.
SET TIME key or HOLD temperature key.
5 Displays "Change Filter"/"Change Pad"/"Change UV
Lamp" when the system has run for the programmed
filter/humidity pad/UV lamp time period as a reminder
to change or clean your filter/humidity pad or to replace
UV lamp.
6 COPY key or INSTALLER CONFIG key.
7 CLEAN DISPLAY key allows 30 seconds to wipe off
the display or ADVANCE DAY key for programming.
8 Used in programming to set time and in configuration
menu to change selections.
9 "Hold Until" indicates the time when a temporary hold
period will end.
10 "Hours" and "Days" displays during steps in installer
configuration.
11 The words "Hold At" are displayed when the
thermostat is in the HOLD mode. "Temporary Hold
At" is displayed when the thermostat is in a temporary
HOLD mode.
12 "Humidity" indicates that the "Set At" display is Hu-
midity setpoint.
13 "System On" indicates when heating or cooling stage
is energized. "+2" indicates when a second stage is
energized.
14 "Copy" indicates the copy program feature is being
used during programming.
Figure 9 – Programming & Configuration Items
7
15
65
1234567891
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
3
20
21
2
1
11 12
10
16 17
9
8
18
14
13
4
19
15 A steady "Cool Savings" display indicates the feature
is enabled in the installer menu. A flashing "Cool
Savings" display indicates the feature is active.
16 "Remote" indicates that the indoor remote temperature
sensor, is being accessed. "Outdoor Remote" indi-
cates the outdoor remote temperature sensor is being
accessed.
17 Display time, remote temperature or humidity.
18 "Heat Pump" displays when the system configuration
is set in HP1/HP2.
19
"Call for Service" indicates a fault in the heating/cooling
systems. It does not indicate a fault in the thermostat.
20
Auto Schedule key for Auto Schedule function or
Humidity key to display current Humidity and Humidity
setpoint.
21 In Configuration Menu, shows screen number. If blank,
thermostat is earlier model and requires instruction sheet
37-6914E.
THERMOSTAT QUICK REFERENCE
Home Screen Description
Time of Day
Day of Week
Room
Temperature
System
Switch
Fan
Switch
Indicates when
thermostat is calling
for Heat or Cool
Battery Level Indicator
Indicating the current power level
of the 2 “AA” batteries.
Full power remaining.
Half power remaining.
Change The batteries should be replaced at this time.
Menu key for entering
different modes such as
Cleaning, Configuration, Set
Time and Set Schedule
Press to view
Humidity setpoint
Temperature
UP/Down used for
modifying setpoint
as well as to
navigating the menus
Set Temperature/Humidity
Note: If is displayed, the
thermostat is battery powered.
When battery power remaining
is approximately half, will
be displayed. If the home is
going to be unoccupied for an
extended period (over 3 months)
and is displayed, the batteries
should be replaced before leaving.
Figure 8 – Home Screen Display
6
INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touch key. This displays
screen reference #1 in the table below. Screen Reference numbers appear in top right corner of display. Press to advance
to the next menu item or to return to a previous menu item. Press or to change a menu item option. Shaded items are
not available if selected for Non-Programmable. Write the options selected in the "Option Selected" column of the menu.
Installer Note: To default the programming, clock and Configuration Menu to the Factory Default Settings, press the ,
and SYSTEM keys simultaneously. The thermostat display will go blank for a few seconds, and then all segments will display
momentarily. For heat pump systems, Configuration Menu items 1 and 3 must be set to match the heat pump system.
CONFIGURATION MENU
Screen
Reference
Number
SS1
MS2
HP1
HP2
Press
key
Displayed
Factory
(Default)
Press or
to select from
listed options
Comments Option
Selected
1- - MS 2 HP 1, HP 2, SS 1 Selects Multi-Stage (MS2, No Heat Pump), Heat Pump 1
(HP1, 1 compressor), Heat Pump 2 (HP2, 2 compressor
or 2 speed compressor), or Single Stage.
2- - (GAS) ELE GAS setting: furnace controls blower.
ELE setting: thermostat controls blower.
3-0b (0) b Selects Reversing Valve (This item is only to appear if HP1 or HP2
is selected above.)
4- - Days, (7) P 5 or 0Programs per week. (7 days, 5+1+1 days or non-programmable)
5- - (4) PS 2 Programs per day.
4 = Morning, Day, Evening, Night
2 = Day, Night
Not available if 4 is 0
6-Cool-Off-
Heat-Auto
Cool-Off-Heat, Heat Off,
Heat, Cool-Off, Auto Off
System switch configuration in non heat pump mode.
-Cool-Off-Heat-
Em-Auto
Cool-Off-Heat-Em,
Off-Em-Auto
System switch configuration, heat pump mode.
7- - (On) EOFF Selects Energy Management Recovery. Not available if 4 is 0
8- - (FA) Heat, Cr SL Selects Adjustable Anticipation, cycle rate, Heat
9- - (FA) Cool, Cr SL Selects Adjustable Anticipation, cycle rate, Cool
10 -(FA) Cr/AU, Em SL Selects Adjustable Anticipation, cycle rate auxiliary, (This item is
only to appear if HP1 or HP2 is selected above).
11 - - (OFF) CL On Selects Compressor Lockout.
12 - - (On) dL OFF Selects Continuous Display backlight.
13 - - 0
(Temperature)
5, LO to 5, HI Selects Adjustable Ambient Temperature Display [range -5 (LO) to
+5 (HI)].
14 - - °F °C Selects °F/°C Display (temperature units in Fahrenheit or Celsius).
15 - - (On) bOFF Selects audible Beeper On/Off.
16 - - (On) dS OFF Selects Daylight Saving Time calculation.
17 - - (On) Heat, AS OFF Selects Automatic Schedule for comfort temperature Programming,
heat mode. Not available if 4 is 0
18 - - (On) Cool, AS OFF Selects Automatic Schedule for comfort temperature Programming,
cool mode. Not available if 4 is 0
19 - - (OFF) CS On Selects Cool Savings Feature On of Off.
20 - - CS Cool Savings
(3)
1-2-3-4-5-6 Selects amount of Cool Savings adjustment.
21 - - (Off) CO On Select Compressor Optimization (not available on earlier models)
22 - - (OFF) CA On Selects Comfort Alert Feature On or Off. (not available on earlier
models)
23 - - (99) Heat, HL 62-98 TEMPERATURE LIMIT, HEAT (max. heat set point).
24 - - (45) Cool, LL 46-82 TEMPERATURE LIMIT, COOL (min. cool set point).
25 - - OFF,
Keypad Lockout
L (total), P (partial),
Temperature Limit
(limited temperature range)
Selects Keypad Lockout.
26 - - 000 001-999 Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
27 - - (On) Heat, FS OFF Fast second stage of heat (not available if SS1 is selected above).
28 - - (On) Cool, FS OFF Fast second stage of cool (not available if SS1 or HP1 is selected
above).
29 - - Remote (OFF) On Remote temperature sensor, enable/disable.
30 - - Remote, In Outdoor Remote Remote temperature sensor (Indoor/Outdoor).
31 - - (On) LS OFF Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
32 -(OFF) dF On Selects Dual Fuel feature On or OFF (this item appears if HP1 or
HP2 is selected above).
7
INSTALLER/CONFIGURATION MENU
1. This control can be configured for:
MS2 – Multi-Stage System (2 heat/2 cool)
HP1 – Heat Pump with one stage of compressor (2
heat/1 cool)
HP2 – Heat Pump with two stage compressor or two
compressor system, Gas or Electric backup; (Dual Fuel
see screen reference number 33) (4 heat/2 cool)
SS1 – Single Stage System (3 wire zone see wiring
diagrams.
2. GAS or Electric (ELE) fan operation. If the heating
system requires the thermostat to energize the fan, select
ELE. Select GAS if the heating system energizes the
fan on a call for heat. Note: Resetting the thermostat
switches the option to GAS.
3. O/B Terminal selection – Selects the operation of the
reversing valve (when item 1 is set to HP1 or HP2 only).
When set to "O" the changeover valve will be energized
in COOL to accommodate the majority of heat applica-
tions. If the heat pump requires the changeover valve to
energize in HEAT, select "B".
4. Programs per week This control can be configured for
7 independent day or 5+1+1 day programming or non-
programmable modes. Default is 7-day mode. The display
indicates "7 Days" as default. Other options "5 Days" or
"0 Days" can be selected. If "0 Days" is selected for non-
programmable mode, the step for EMR will be skipped, as
this feature will not be available in this mode.
5. Program Steps per day – Not available if configured for
non-programmable. This control can be configured for 4
or 2 program steps per day. Default is "4 PS" and can be
toggled between 4 PS and 2 PS.
6. System Switch Configuration (MS2/SS1) – This ther-
mostat is configured for Heat and Cool with Auto change-
over default (Cool-Off-Heat-Auto). It can be configured as
Heat & Cool (Cool-Off-Heat), or Heat Only (Off-Heat), or
Cool Only (Cool-Off).
When the control is in heat pump configuration (HP1/
HP2), the system switch configuration will have an
additional mode, Em for Emergency.
7. Energy Management Recovery (EMR) – (this step is
skipped if configured as non-programmable). When set
to "On" causes the thermostat to start heating or cooling
early to make the building temperature reach the program
setpoint at the time you specify.
Example: The heating program is 65°F at night and 70°
at 7 AM. If the building temperature is 65°F, the difference
is 5°F. Allowing 5 minutes per °F rise, the thermostat set-
point will change to 70° at 6:35 AM. Cooling allows more
time per °F, because it takes longer to reach temperature.
8, 9 & 10. Cycle Rate SelectionThe factory default setting
is fast cycle (FA Cr) in all modes (Heat, Cool, Em). To
change to slow cycling (SL, Cr), press touch keys or
toggle between FA & SL. The cycle rates are below:
Mode Med Slow
Heat 0.6°F 1.5°F
Cool 1.2°F 1.7°F
Heat Pump 1.2°F 1.7°F
Emer Heat 0.6°F 1.7°F
11. Select Compressor Lockout (CL) – Selecting (CL On)
will cause the thermostat to wait 5 minutes between cool-
ing cycles. This is intended to help protect the compressor
from short cycling. Some of the newer compressors have
CONFIGURATION MENU
Screen
Reference
Number
SS1
MS2
HP1
HP2
Press
key
Displayed
Factory
(Default)
Press or
to select from
listed options
Comments Option
Selected
33 -(35) dF -5 - 50 Selects Dual Fuel setpoint (°F), dF selected On with outdoor sen-
sor available.
34 -(05) dF 0 - 09 Selects Dual Fuel setpoint (°F), dF selected On with no outdoor
sensor.
35 -(60) Cd 0-99 Selects compressor off delay in seconds, dF selected On
36 -(80) AO -5 - 79 Selects Auxiliary Heat cut out temperature. This item appears
if HP1 or HP2 is selected and outdoor sensor is installed and
enabled.
37 -(80) bP 79-20 Selects Blower balance point. Selection of 80 disables this feature.
This item appears if HP1 or HP2 is selected and outdoor sensor is
installed and enabled.
38 - - (OFF) Hd On Selects Humidity Display alternate with time.
39 - - Humidity 00
(Room Humidity)
-20 LO
20 HI
Selects Humidity Display adjustment.
40 - - (OFF) HR LO, HI Selects Auto Humidity reduction.
41 - - (OFF) AH H, C, A Selects Automatic Humidification.
42 - - (OFF) CH On Selects Cycle Humidifier.
43 - - OC (0) od, OFF Selects Optimum Comfort or Optimum Dehumidification or Off.
44 - - (OFF) Change
UV Lamp
On Selects Change UV Lamp feature.
45 - - 350 Days 25-1975 Change UV Lamp duration days.
46 - - (OFF)
Change Pad
On Selects Change Humidifier Pad feature.
47 - - 100 Hrs 25-1975 Change Humidifier Pad duration hours.
48 - - OFF
Change Filter
On Selects Change Filter feature.
49 - - 200 Hrs 25-1975 Change Filter duration hours.
8
a time delay built in and do not require this feature to be
activated in the thermostat. Your compressor manufactur-
er can tell you if this lockout feature is already present in
their system. When the thermostat compressor time delay
is activated, it will flash the set point for up to five minutes.
12. Select Continuous Display Lighting (dL) – In low
lighting conditions, display backlight improves the display
contrast. When C terminal is connected, selecting dL On
will turn the display light on continuously. Selecting dL
Off will turn the display light on momentarily after any
key is pressed. When C terminal is not powered (battery
only), dL On enables the momentary backlight whenever
a key is pressed.
Continuous Display Lighting without common wire
connection When thermostat is Battery Powered with
Power Stealing assist with low voltage 24V connections
to both W and Y terminals, selecting dL "On" will provide
continuous display light.
Note: If power stealing operation is not compatible with either
the W or Y connection (see page 2), or if only a single
connection to W or Y, continuous display light will be
interrupted when the active power stealing connection (W
or Y) is operating the system. In power stealing mode, the
continuous display light will increase in brightness when a
button is pressed. And on some systems with high imped-
ance, the display light may dim slightly when thermostat
is calling for heat or cool.
13. Select Temperature Display Adjustment 5 LO to 5 HI
This allows you to adjust the room temperature display
by -5°F to +5°F in 1° steps. Your thermostat was accu-
rately calibrated at the factory, however you have the
option to change the display temperature value to match
the previous thermostat, if you so prefer.
14. Select °F or °C Readout – Changes the display readout
to Celsius or Fahrenheit as required.
15. Select Audio Prompting (Beeper) On or Off – Factory
default setting is b, On. If you wish to turn off the beeper
select OFF.
16. Select Daylight Saving Time Calculation – This feature
will allow the thermostat to calculate the DST automatically
and apply it to the Real Time Clock display. Default is On.
17 & 18. Select Automatic Schedule – Not available if
configured for non-programmable. This feature allows
programming a “Comfort Temperature” into all program
periods with the Auto Schedule key. When Heat AS
(for Heat mode) or Cool AS (for Cool mode) is selected
On, the Auto Schedule feature is ready to be set. Off
indicates that the feature is not ready to be used or a
“Comfort Temperature" is already set. See Auto Schedule
in Programming section.
19 & 20. Select Cool Savings™ – Cool Savings™ provides an
energy saving temperature offset (from 1-6 degrees) under
peak cooling load conditions (high outdoor temperatures).
If selected on, Cool Savings™ becomes active when the
air-conditioner runs for periods of longer than 20 minutes.
When active, Cool Savings™ gradually offsets the indoor
temperature display downward. The first 1° of adjustment
will take one hour of continuous air conditioner run time
with subsequent 1° adjustments occurring with each ad-
ditional half hour of run time (ex for a 2° offset, the air con-
ditioner would need to run continuously for 1 ½ hours). The
offset is limited to the number of degrees you select from
1 up to 6. When an offset starts or is active, “Cool Savings”
will flash on the display.
The principle of this energy saving feature takes advantage
of the long air conditioning run times lowering the indoor
humidity allowing a slightly higher temperature to feel
comfortable. As the peak load subsides, this feature also
takes advantage of the air conditioner's increased capacity
under more efficient conditions to gradually reduce the off-
set back to zero and return control to the selected setpoint
temperature.
If Cool Savings is selected off, no temperature offset
will occur.
21. Compressor Optimization – (Not available on earlier
models) CO provides a delay in circulator fan operation
after the compressor turns on or off. With CO selected
ON, when the compressor turns on (for a call for heat
in heat pump or a call for cool) the fan will be delayed
for five seconds before turning on to allow the air to be
heated or cooled. After the compressor turns off for call
for cool, the fan will continue to run for 20 seconds to
capture additional cooling from the system. If CO is set to
OFF, there will be no delay in fan operation.
22. Comfort Alert with Active Protection – (not available
on earlier models) Turn this feature ON to enable active
protection. This allows the thermostat to identify fault
codes sent by the Comfort Alert module when compres-
sor damage is possible and react to those codes by
turning the compressor off. Fault codes from the Comfort
Alert module will flash on the thermostat. (Refer to Com-
fort Alert Codes in Troubleshooting section.) If a Comfort
Alert module is not connected, or to disable active protec-
tion, turn this feature OFF. If a Comfort Alert module is
connected and this feature is turned OFF, the thermostat
will still receive and flash the fault codes from the Comfort
Alert module, but the active protection will not be enabled
to protect the compressor.
23. Heat Temperature Limit RangeThis feature adjusts
the highest setpoint temperature for heat. The default set-
ting is 99°F. It can be changed to a setting between 62°F
and 98°F. The "temperature limit" icon will be displayed
to the left of your setpoint temperature when using this
feature. The "temperature limit" icon will flash if an
attempt is made to adjust the temperature beyond the
range selected.
24. Cool Temperature Limit RangeThis feature adjusts
the lowest setpoint temperature for cool. The default
setting is 45°F. It can be changed to a setting between
46°F and 82°F. The "temperature limit" icon will be dis-
played to the left of your setpoint temperature when using
this feature. The "temperature limit" icon will flash if an
attempt is made to adjust the temperature beyond the
range selected.
25 & 26. Keypad LockoutThis step allows you to select
the type of lockout or limited range security required. If no
lockout or limited range security is required, press to
advance the menu.
Three security settings are available in this menu item.
Use the or keys to select the lockout desired.
Lockout selections are:
"Keypad Lockout and L" = Total Lockout. Total Lockout
locks all keys.
"Keypad Lockout and P" = Partial Lockout. Partial Lock-
out allows only the or keys to operate within your
set temperature limits.
"Temperature Limit/Keypad Lockout" prevents chang-
ing the temperature limits in the Configuration Menu.
After the type of lockout is selected, press .
Keypad Lockout Combination Number Selection
Display will read "000" "Keypad Lockout".
INSTALLER/CONFIGURATION MENU
9
Skip this step and continue through the remainder of the
configuration menu if you require an Air Filter Change
out indicator or Humidifier Pad Change out indicator by
pressing the key to advance.
Return to this point when you are ready to start your
selected lock-out and continue by:
Pressing or keys to select your keypad lockout
combination number. Note: "000" is not a valid combina-
tion choice.
Record the number you select for future use.
Press
to exit the menu. The security feature you select
will start in 10 seconds. The system key will remain active
for 10 seconds to allow setting Heat, Off, Cool or Auto.
To unlock the keypad, press Menu, then press Installer
Config. Display will show "000" and keypad lock. Enter
the code used to lock the keypad and press .
27 & 28. Select Fast Second Stage, ON or OFF – Not
available if configured for SS1. Selecting FA ON forces
additional heat stages to come on quickly when is
used to raise the temperature a few degrees above the
room. Select this setting if you want the heat to increase
quickly when you manually raise the temperature.
Selecting FA OFF allows the thermostat to calculate an
optimal time to bring on additional stages of heat. When
the is used to raise the setting above the room tem-
perature additional heat stages may come on very quickly
or very slowly (up to 30 minutes later) depending on
recent system performance. Select this setting if you do
not require the additional heat stages to come on quickly
when you manually raise the setting and want to allow the
thermostat to stage based on recent system performance.
The Fast Cool feature operates the cooling stages in the
same manner as Fast Heat, On or Off when the tempera-
ture is lowered below the room setting.
29. Select Remote Temperature Sensor Enabled – ON
enables a remote sensor connected to thermostat and dis-
plays the sensor temperature in the clock digits. OFF (de-
fault) indicates no remote sensor connected or enabled.
30. Select Remote Sensor as Indoor or Outdoor – If 30
is enabled, select the remote to be Remote In (Indoor,
F145-1328) or Outdoor Remote (Outdoor, F145-1378).
Default is Remote In.
31. Select Local Sensor Disable – If 31 is selected Indoor,
the thermostat Local Sensor can be disabled so the
displayed temperature will be from the Remote Sensor.
Default is On LS. To disable the Local Sensor, change
selection to OFF LS.
32. Select Dual Fuel Feature (dF) – This feature is appli-
cable only in heat pump modes (HP1, HP2). Enables (On)
or disables (Off) dual fuel feature of thermostat.
33. Select Dual Fuel Temperature With dF selected On
and outdoor remote sensor available, select the outdoor
temperature the thermostat will use to determine when to
switch to gas heat and shut down the compressor. When
the outdoor temperature falls below the selected tem-
perature the gas heat will begin. Default is 35°, but can be
set in the range of -5 to 50°. A lower setting will delay the
start of gas heat allowing cooler temperature in the home.
34. Select Dual Fuel SettingWith DF selected On and no
outdoor sensor, select the dF setting from 01-09. Fac-
tory default is 05. The dF setting influences when second
stage comes on. The factory default creates a separation
of approximately 1°F between stages. Increasing the set-
ting decreases the separation between stages. Decreas-
ing the value increases stage separation. This adjust-
ment allows a small change in the operation of your heat
INSTALLER/CONFIGURATION MENU
pump system versus your auxiliary system relative to the
thermostat adjustment. The higher the number the sooner
the auxiliary stage energizes for better comfort. The lower
the number the longer period of time before auxiliary is
energized for more economy.
Note: This setting is not minutes or degrees. It is numeric set-
ting that will influence the internal thermostat calculation
for staging.
35. Select Compressor Delay (Cd) – After the auxiliary heat
is turned on, the compressor(s) shut down is delayed for
the time selected (in seconds). This delay is factory set to
60, but can be set in the range of 0 to 99.
36. Select Auxiliary Off (AO) – Applicable with HP1 or HP2
selected with outdoor sensor. Select the temperature
that will inhibit the auxiliary heating stage. As long as the
outdoor temperature is above the selected temperature,
the auxiliary heat will not turn on. The default setting is
80°(disabled), but can be set in the range of -5 ° to 79°.
Thermostat will not allow a setting at or below the (dF)
dual fuel setting.
If indoor temperature drops below 45° because of a pos-
sible heat pump malfunction, the thermostat will turn off
the pump and switch to Auxiliary heat. "Call for Service"
will display on screen.
There are two ways the thermostat will return to normal
heat pump operation:
• Pressanykeytoretrythepumpanderasethe"callfor
service icon.
• WhensetpointisachievedonAuxiliary,systemwill
return to heat pump operation on next call for heat.
37. Select Programmable Blower Balance Point (bP)
Applicable with HP1 or HP2 selected, dF On with outdoor
sensor. Requires DHM connection from thermostat to
heat pump system. This feature de-energizes the DHM
terminal to operate the blower at a slower speed for first
stage heat when the outdoor temperature is below the
temperature selected. This circulates warmer air than the
higher fan speed. The default is 80° (disabled), but can be
set from 20° to 79°. Select an outdoor temperature where
the air coming out of the ducts begins to feel cool and the
thermostat will lower the fan speed to circulate warmer air.
38. Humidity Display (Hd) – Selecting HD On enables the
display to alternately show the current time and the hu-
midity. If HD is selected OFF, the display will not show the
humidity. (See page 10 for Humidity setpoint range)
39. Adjustable Humidity DisplayThe display will show
the ambient humidity and 00 (default). The setting can
be changed from -20 and LO to 20 and HI. The displayed
humidity will change as the offset is changed. In Run
mode, the displayed humidity will be the ambient humidity
adjusted by the setting selected.
40. Auto Humidity Reduction (HR)This feature au-
tomatically lowers humidity setting when the outside
temperature drops to prevent the interior windows/walls
from reaching the dew point where water condenses on
surfaces. This feature default is OFF. It can be changed
to select LO (low humidity reduction) or HI. To achieve
automatic humidity reduction, the thermostat lowers the
humidity when furnace cycles are long. When the outside
temperature rises, it increases humidity. "LO" indicates a
low amount of humidity reduction.
41. Automatic Humidification (AH)This feature if enabled
allows for humidification independent of a call for heating
– useful in arid climates where addition humidification in
heating and/or cooling is desired. If enabled, will energize
the humidifier and circulator blower (“G” terminal and the
10
“HM” terminal) if the actual humidity is below the humid-
ity set point. The display indicates AH. Pressing the
key will cycle the display from OFF to H (feature enabled
in Heat mode) to C (feature enabled in Cool mode) to A
(feature enabled to Auto mode) and back to OFF.
42. Cycle Humidifier (CH)This feature provides an op-
tion that reduces the water usage by up to 50% when a
flow-through humidifier is controlled by the thermostat. It
is recommended for use on flow-through humidifiers only.
The display indicates CH (Cycle Humidifier) with the de-
fault indicating OFF. Pressing the or keys will toggle
the display from OFF to On and back to OFF. When CH is
enabled, the humidifier will cycle to turn off for 10 minutes
after it has run for 10 minutes. The blower and/or furnace
will continue to run during the humidifier off period.
43. Programmable Dehumidification Optimal Comfort
Mode (OC) or Optimal Dehumidification (Od) – This
item can be selected to OC (Optimal Comfort mode), Od
(Optimal Dehumidification), or OFF. When Optimal Com-
fort (OC) is enabled, this feature automatically reduces
indoor humidity with a call for Cooling if humidity is 2%
above humidity setpoint. Humidity is set by pressing the
Humidity key when in the appropriate mode, in this case
Cooling, and pressing the or keys to set desired
humidity (range 40% to 95%) level followed by pressing
Humidity key again. This dehumidification feature uses
less energy by maintaining temperature and dehumidify-
ing only when a call for Cooling is required. Optimal De-
humidification (Od) when enabled, this feature automati-
cally reduces indoor humidity with a call for Cooling if
humidity is 2% above setting. Humidity is set by pressing
the HUMIDITY key when in the appropriate mode, in
this case Cooling, and pressing the or keys to set
desired humidity level followed by pressing Humidity key
INSTALLER/CONFIGURATION MENU
again. This dehumidification feature may use more energy
by making dehumidification a priority initiating a call for
cooling if humidity is 2% above desired setting. This
feature may also over-cool the condition space by up to 3
degrees to achieve the desired humidity level. (Note: Both
dehumidification modes operate in Cooling mode only
with a call for cooling)
44 & 45. Change UV LampThis feature allows the thermo-
stat to display the words "Change UV Lamp" (Call for
Service of UV bulb) after a set time of UV bulb operation.
This is a reminder to maintain your UV system at opti-
mum level of operation. When enabled, the factory set
interval for "Change UV Lamp" to be displayed is 350
days of UV bulb operation and can be adjusted in 25 day
increments. This should be adjusted with respect to the
bulb’s recommended maintenance schedule.
When "Change UV Lamp" is displayed, you can clear it
by pressing Clean Display.
46 & 47. Change Humidifier PadThis feature allows the
thermostat to display the words "Change Pad" after a set
time of humidifier operation. This is a reminder to main-
tain or clean your humidifier. The factory set interval for
"Change Pad" to be displayed is 100 hours of humidifier
operation. This should be adjusted with respect to the
humidifier’s recommended maintenance schedule.
When "Change Pad" is displayed, you can clear it by
pressing Clean Display.
48 & 49. Select Change Filter Run TimeThis feature
allows thermostat to display "Change Filter" after a set
time of blower operation. This is a reminder to change
or clean your air filter. This time can be set from 25 to
1975 hours in 25 hour increments. A selection of OFF will
cancel this feature. When "Change Filter" is displayed,
you can clear it by pressing Clean Display. In a typical ap-
plication, 200 hours of run time is approximately 30 days.
OPERATING YOUR THERMOSTAT
If at any time during testing your system does not operate
properly, contact a qualified service person.
Fan Operation
If your system does not have a G terminal connection, skip to
Heating System.
1. Turn on power to system.
2. Press FAN key to ON position. The blower should begin
to operate.
3. Press FAN key to AUTO position. The blower should
stop immediately.
To prevent static discharge problems, touch side of
thermostat to release static build-up before touching
any keys.
NOTE
Check Thermostat Operation
Do not allow the compressor to run unless the compres-
sor oil heaters have been operational for 6 hours and the
system has not been operational for at least 5 minutes.
CAUTION
!
Heating/Humidifier
1. Press SYSTEM key to select HEAT. If the auxiliary heating
system has a standing pilot, be sure to light it.
2. Press to adjust thermostat setting to 1° above the
room temperature. The heat pump system should begin to
operate. The display should show "System On". How-
ever, if the system configuration is set to HP1 or HP2
and setpoint temperature display is flashing, the 5 minute
compressor lockout feature is operating (see Configura-
tion menu, item 11).
3. Adjust temperature setting to 3° above room temperature.
If your system configuration is set at MS2, HP1 or HP2,
the auxiliary heat system should begin to operate and the
display will show "System On +2".
4. Press to adjust the thermostat below room tempera-
ture. The heating system should stop operating.
To check the humidifier when System On appears and the
heating system is running press the HUMIDITY* button once.
Press to adjust the humidity 2% or more above the room
humidity level setpoint range. (Humidity setpoint can be
adjusted from 5 to 50%.) Hum On will appear indicating it is
calling for the humidifier.
*Note: If Auto Schedule is displayed instead of Humidity,
Auto Schedule must be turned off in the Configuration Menu.
11
Emergency Mode
Applies only to Heat Pump Systems
Emergency Heat (System EM Position) bypasses the Heat
Pump to use the heat source wired to terminal W/E, W2 on
the thermostat. EM is typically used when compressor opera-
tion is not desired, or you prefer back-up heat only.
1. Press SYSTEM key to select EM. “EM Heat Mode” will
flash on the display.
2. Press to adjust thermostat setting above room tem-
perature. The Emergency heating system will begin to
operate. The display will show “System On” flashing “EM
Heat Mode” and “Heat” to indicate that the Emergency sys-
tem is operating.
3. Adjust temperature setting to 3° above room temperature.
Any additional stages of auxiliary heat should begin to
operate and the display will show "System On +2".
4. Press to adjust the thermostat below room tempera-
ture. The heating system should stop operating.
Cooling/Dehumidifier
1. Press SYSTEM to select "Cool".
2. Press to adjust the thermostat setting below room tem-
perature. The blower should come on immediately on high
speed, followed by cold air circulation. The display should
show "System On". If the setpoint temperature display is
flashing, the compressor lockout feature is operating (see
Configuration menu, item 11).
3. Adjust temperature setting to 3° below room temperature.
The second stage cooling should begin to operate and the
display should show "System On +2".
4. Press to adjust the temperature setting above room
temperature. The cooling system should stop operating.
To check the dehumidifier when System On appears and
the cooling system is running press HUMIDITY* button once.
Press to adjust the humidity 2% or more below the room
humidity level setpoint range. DeHum On will appear indicat-
ing it is calling for the dehumidification.
If the room humidity is lower than the adjustment range, press
to 40% and hold it for four seconds. This will force the De-
Hum On for one complete cooling cycle to test the dehumidi-
fication equipment.
After adjusting the humidity setting the display will return to
temperature in approximately 10 seconds. To switch the dis-
play back to temperature immediately after adjusting humidity
setting press HUMIDITY again.
*Note: If Auto Schedule is displayed instead of Humidity,
Auto Schedule must be turned off in the Configuration Menu.
Choose the Fan Setting (Auto or On)
Fan Auto is the most commonly selected setting and runs the
fan only when the heating or cooling system is on.
To prevent compressor and/or property damage, if the
outdoor temperature is below 50°F, DO NOT operate
the cooling system.
CAUTION
!
Fan On selection runs the fan continuously for increased air
circulation or to allow additional air cleaning.
Tip: Running the fan more frequently will increase your
energy consumption. Most systems use a 1/2 or 1/3 HP
electric motor to power the fan.
Choose the System Setting
(Cool, Off, Heat, Em, Auto)
Press the SYSTEM key to select:
Cool: Thermostat controls only the cooling system.
Off: Heating and Cooling systems are off.
Heat: Thermostat controls only the heating system.
Em: Setting is available only when the thermostat is config-
ured in HP1 or HP2 mode.
Auto: Auto Changeover is used in areas where both heating
and cooling may be required on the same day. AUTO allows
the thermostat to automatically select heating or cooling
depending on the indoor temperature and the selected heat
and cool temperatures. When using AUTO, be sure to set the
Cooling temperatures more than 1° Fahrenheit higher than
the heating temperature.
Manual Operation for
Non-Programmable Mode
Press the SYSTEM key to select "Heat" or "Cool" and use
the keys to adjust the temperature to your desired setting.
After selecting your desired settings you can also press the
SYSTEM key to select AUTO to allow the thermostat to auto-
matically change between "Heat" and "Cool".
Manual Operation (Bypassing the Program)
Programmable Mode
Manual operation will bypass the program and allow you to
adjust the temperature as you desire. The temperature you
set in Hold will be maintained indefinitely. Press or to
adjust the temperature. The HOLD key will appear. Press the
HOLD key. "Hold At" will appear next to the setpoint tem-
perature and the thermostat will maintain the new setpoint
temperature until Run Schedule is pressed to resume pro-
gram operation.
Program Override (Temporary Override)
Press or keys to adjust the temperature. This will over-
ride the temperature setting for a (default) four hour override
period. The override period can be shortened by pressing
or lengthened by pressing . Program Override period can
range from 15 minutes to 7 days.
Example: If you turn up the heat during the morning program,
it will be automatically lowered later, when the temporary hold
period ends. To cancel the temporary setting at any time and
return to the program, press Run Schedule.
If the SYSTEM key is pressed to select AUTO the
thermostat will change to "Heat" or "Cool", whichever
ran last. If it switches to "Heat", but you want "Cool", or it
changes to "Cool", but you want "Heat", press both keys
simultaneously to change to the other mode.
OPERATING YOUR THERMOSTAT
12
PROGRAMMING
Set Current Time and Day
1. Press Menu key to enter installer menu. Then press
Set Time once to indicate hour & AM or PM designation
in clock display.
2. Press and hold either the or touch key until you
reach the correct hour and AM or PM designation.
3. Press Set Time again to display minutes only in clock
display.
4. Press and hold either the or touch keys until you
reach the correct minutes.
5. Press Set Time once again to display year.
6. Press either the or touch key until you reach the
correct year.
7. Press Set Time once again to display month.
8. Press either the or touch key until you reach the
correct month.
9. Press Set Time once again to display date of the month
along with day of the week at top row (which is automatic).
10. Press and hold either the or touch key until you
reach the correct day of the month and day of the week
displayed at the top row.
11. Press Run Schedule once or twice to remove the key.
Now the display will show the correct time and room tem-
perature.
Automatic Daylight Saving Calculation
The Real Time Clock will adjust automatically for daylight sav-
ings time, in the following manner:
Increment one hour at 2 AM on the second Sunday of March
and decrement one hour at 2 AM on the first Sunday of
November.
The daylight saving feature can be enabled or disabled in
installer configuration menu. Default is DS ON (enabled).
After entering installer configuration mode, momentarily
press touch key until the display indicates dS (in actual tem-
perature digits) and on (default – in clock digits). and
keys will toggle display and operation from on to OFF.
Programming Tip: Copy Program
When programming your thermostat, you may copy the pro-
gram from one day to another day or group of days using the
Copy key. In 7 day programming mode, a day can be copied
to another day or all six other days. In 5+1+1 day program-
ming mode the weekday (Mon – Fri) program can be copied
into Sat and Sun or either Sat or Sun.
To copy a program from one day to another:
1. In Set Schedule mode, enter the program for the day or
select the day you wish to copy by pressing Advance Day.
2. Press Copy. The display will show “Copy” next to the
SYSTEM key and the day of the week that will be copied.
3. Press Advance Day. The day being copied will be indi-
cated and the other days will be flashing.
4. If you wish to copy to all days skip to next step or press
Advance Day until the day you wish to copy to is flashing.
5. Press Copy. “Copy” will disappear, the day you copied
from will disappear and the day(s) you copied to will be on.
6. If you wish to copy this same program into other days,
press Copy and repeat steps 3, 4 and 5.
7. Press Run Schedule to return to normal operation.
Fill in the blank schedule on the next page then:
Enter the Heating Program
1. Press the Menu key and then press Set Schedule. Press
SYSTEM key to select "Heat" in the system switch area
indicating the active mode being programmed. You can
switch to the other mode by pressing the system switch at
any time.
2. The top of the display will show the day(s) being pro-
grammed. The time and set at temperature are also
displayed. "Morning" will also be displayed to indicate
the period.
3. Press or key to change the temperature to your
selected temperature for the 1st heating period (Morning).
4. Press or key to adjust the start time for period.
The time will change in 15 minute increments.
5. Press FAN to select Auto or Prog.
6. After you have set the time and the temperature for the
period to begin, press Set Schedule to advance to the
next program period.
7. Repeat steps 2 through 6 until all of the program times
and temperatures are set for all program periods on
that day.
8. Press "Advance Day" to change to the next day and
repeat steps 2 through 8.
9. When programming is complete and all of the times and
temperatures match your desired heating schedule,
press Run Schedule. The thermostat will now run your
program.
Enter the Cooling Program
1. Press the SYSTEM key until the "Cool" icon appears.
2. Follow Enter Heating Program instructions for entering
cooling times and temperatures.
Automatic Schedule
Auto Schedule Heat is a fast way to program all the heating
temperatures during the day to a comfortable temperature
and then lower the temperature 6° at night. Auto Schedule
Cool will program all of the cooling time periods to the same
temperature.
Note: Auto Schedule is available only when the thermostat
is first powered on, after the thermostat has been reset, or
anytime you turn AS on in the Configuration Menu (item 17
AS Heat or 18 AS Cool). After use in heating and cooling,
Auto Schedule on the display will change to Humidity.
Heating Example:
1. In Heat mode, press Auto Schedule once.
2. Press or to select a comfortable day time tempera-
ture (example 72°).
3. Press Auto Schedule again. Your thermostat is now pro-
grammed for 72° from 6:30 AM until 10:30 PM at 72°. At
10:30 PM, your thermostat will set back 6° to 66°.
Your heating program for each day of the week will look like
this:
6:30 72°
8:00 72°
5:00 72°
10:30 66°
13
PROGRAMMING
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The 1F95-1291 comes configured for 7 day programming and can also be configured for 5+1+1 programming (see configura-
tion section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your
own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day schedule, fill in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
• InHeating,lowertemperatureswillsaveenergy.
• InCooling,highertemperatureswillsaveenergy.
• IfyouplanonusingAutoChangeover,donotprogramtheheatingtemperaturehigherthanthecoolingtemperature.
Energy Saving Factory Pre-Program
The 1F95-1291 thermostats are programmed with the energy saving settings shown in the table below for all days of the week.
If this program suits your needs, simply set the thermostat clock and press the RUN key.
The table below shows the factory set heating and cooling schedule for all days of the week.
* You can eliminate these two program periods in the configuration menu (reference #5) if the building is occupied all day.
Day period will change to 6:00 AM and 70° and can be programmed as required.
* Wake Up
(Morning)
Leave For Work
(Day)
* Return Home
(Evening)
Go To Bed
(Night)
Heating Program 6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
Cooling Program 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F
Programmable Fan Option
In the Set Schedule mode, the Fan key is used to select the
fan operation during a program period. The default state of
the Fan key is FAN Auto (fan runs during a call for cool but
not on a call for heat). It can be changed to FAN Prog (fan
runs during a program period). Each press of the FAN key will
change the mode of the fan between Auto and Prog.
In the Run mode, when a program period that has FAN Prog
begins, the fan will turn on and stay on during the complete
period. The display will show FAN On Prog. Pressing the FAN
key will change FAN On Prog to On (fan running continuous-
ly) or Auto. To return to FAN On Prog, press Run Schedule.
Cooling Example:
1. In cool, press Auto Schedule once.
2. Press or to select a comfortable cooling tempera-
ture (example 75°).
3. Press Auto Schedule again. Your thermostat is now pro-
grammed for 75° for all cooling time periods.
Your cooling program for each day of the week will look like
this:
6:30 75°
8:00 75°
5:00 75°
10:30 75°
14
PROGRAMMING
Cooling
Program
Wake Up
(Morning) Fan
Leave For Work
(Day) Fan
Return Home
(Evening) Fan
Go To Bed
(Night) Fan
MON
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
SUN
6:00 AM 75°F Auto 8:00 AM 83°F Auto 5:00 PM 75°F Auto 10:00 PM 78°F Auto
Worksheet for Re-Programming 5+1+1 and 7 Day Program
Heating
Program
Wake Up
(Morning) Fan
Leave For Work
(Day) Fan
Return Home
(Evening) Fan
Go To Bed
(Night) Fan
MON
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
SUN
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
Wired Remote Temperature Sensing
One remote temperature sensor can be installed indoor or
outdoor and connected to the thermostat by a maximum
cable length of 100 meters (300 feet). Terminals +, S and - on
the terminal block allow connection of the remote sensor.
The thermostat must have 24 VAC Common connection to
terminal C for the remote sensor to operate. The remote sen-
sor can be enabled or disabled in the Installer/Configuration
menu, item 29.
When remote sensor, Remote, is selected Off (factory de-
fault), no remote sensor is enabled. When remote sensor is
selected On, the next step is to select the remote as indoor,
Remote In, or outdoor, Outdoor Remote. If the remote is se-
lected as Remote In, an additional step will be to select if the
temperature shown on the display will be from the thermostat,
LS On, or the remote sensor LS Off.
In normal operation, when a remote sensor is enabled the
time digits of the display will alternate between the time and
the remote temperature for three seconds each. Above the
remote temperature will be Remote, for indoor sensor or
Outdoor Remote, for outdoor sensor. If the remote sensor is
an indoor sensor and the local display has been disabled, the
temperature displayed as the room temperature will be the
remote sensor temperature.
Sensing Range:
Outdoor temperature range is -40oF to 140oF
Indoor temperature range is 32oF to 99 oF
15
PROGRAMMING
TROUBLESHOOTING
Averaging or Weighting Remote Sensors
The thermostat will weight or average the temperature of the
indoor remote sensor with the local sensor in the thermostat
for each program period. The averaging will be active only
when the local sensor and the indoor remote sensor are both
functional and enabled in the Installer/Configuration menu.
When the thermostat is in the Set Schedule mode, the weight
of the indoor sensor will be shown in the current temperature
digits of the display. The weight will show as A2 (average and
default), H4 (high) or L1 (low). Pressing the and keys at
the same time will change the weight for the program period.
The weight of the thermostat sensor is fixed.
In normal operation of the thermostat, the current tempera-
ture displayed will be the weighted average of the local
sensor and the remote sensor using the formula (local sensor
weight x local sensor temperature) + (remote sensor weight x
remote sensor temperature) / (local sensor weight + remote
sensor weight).
Example: Local sensor temperature is 80° and the remote
sensor is 70°.
If weight is selected H4, the averaged temperature of 72° will
be displayed.
(1 x 80) + (4 x 70) / 5 = 72°
If weight is selected A2, the average temperature of 73° will
be displayed.
(1 x 80) + (2 x 70) / 3 = 73.3°
If weight is selected L1, the average temperature of 75° will
be displayed.
(1 x 80) + (1 x 70) / 2 = 75°
The example shows that the weight selected would prioritize
the overall averaged temperature between the two sensors.
The high weight selection caused the remote sensor to have
a higher influence in the calculated temperature average than
the local sensor and the low weight selection caused the
remote sensor to have less influence.
Dual Fuel Temperature Setpoint
When the thermostat is configured for Heat Pump mode and
the Dual Fuel feature is selected on, the thermostat can moni-
tor the outside temperature using remote sensor F145-1378
or use software logic to determine when to switch to gas heat
and shut down the compressor. This eliminates the need for a
fossil fuel kit.
The user selectable temperature is called the dual fuel tem-
perature setpoint, dF and is set in the Installer/Configuration
menu, items 33 or 34. With outdoor remote sensor installed
and enabled, the dual fuel temperature setpoint (menu item
33) can be set to a temperature of -5° through 50°. When
outdoor remote sensor is not installed, a software logic
based dual fuel number (menu item 34) from 01 to 09 can be
selected. A higher temperature or dual fuel setting will provide
a smaller stage separation between the heat pump and Aux
to give more comfort. A lower temperature or number will
provide a larger stage separation for more economy.
After the dual fuel temperature setpoint is set and is
pressed, a delay, Cd, can be set for compressor shutdown
after the auxiliary stage is energized. This delay can be set
from 0 seconds to 99 seconds to minimize the time that the
system may blow cooler air until the alternate source of heat
comes on. Default setting for delay is 60. When setting the
delay, if the or keys are held depressed, the setpoint
will increase or decrease at the rate of one degree every half
second for the first three seconds and double the speed after
three seconds.
Blower Balance Point for Heating
Requires DHM connection from thermostat to heat pump
system. Air to air heat pumps use a fast fan speed to circu-
late warm air for first stage heating. As outdoor temperatures
drop, the heat pump produces less heat and a high fan speed
makes the air from the ducts feel cooler. Blower Balance Point
allows you to select an outdoor temperature to slow the fan
speed so the air from the duct feels warmer. Select an out-
door temperature where the air from the ducts starts to feel
cool (Installer Configuration Menu item 37). When the outdoor
temperature drops to the selected temperature, the thermo-
stat will slow the fan speed so the outlet air feels warmer.
Comfort Alert Codes
The Comfort Alert diagnostics product monitors the air con-
ditioning outdoor systems with single phase Copeland Scroll
compressors. Abnormal system and electrical conditions are
indicated by flashing ALERT codes on the yellow LED on the
Comfort Alert module. The flash codes are transmitted to the
thermostat by the Comfort Alert Thermostat interface module.
The Comfort Alert compatible thermostat displays “Call For
Service” that flashes at the same rate as the yellow LED on
the Comfort Alert module.
Comfort Alert Codes
1 Flash Long run time
2 Flashs System pressure trip
3 Flashs Short cycling
4 Flashs Locked rotor
5 Flashs Open circuit
6 Flashs Open start circuit
7 Flashs Open run circuit
8 Flashs Welded Contactor
9 Flashs Low voltage
White-Rodgers is a business
of Emerson Electric Co.
The Emerson logo is a
trademark and service mark
of Emerson Electric Co.
HOMEOWNER HELP LINE: 1-800-284-2925
Symptom Possible Cause Corrective Action
No Heat/No Cool/No Fan
(common problems)
1. Blown fuse or tripped circuit breaker.
2. Furnace power switch to OFF.
3. Furnace blower compartment door or
panel loose or not properly installed.
4. Loose connection to thermostat or system.
Replace fuse or reset breaker.
Turn switch to ON.
Replace door panel in proper position to engage safety
interlock or door switch.
Tighten connections.
No Heat 1. Pilot light not lit.
2. Furnace Lock-Out Condition. Heat
may also be intermittent.
3. Heating system requires service or
thermostat requires replacement.
Re-light pilot.
Many furnaces have safety devices that shut down when
a lock-out condition occurs. If the heat works intermittently
contact the furnace manufacturer or local HVAC service
person for assistance.
Diagnostic: Set SYSTEM Switch to HEAT and raise the
setpoint above room temperature. Within a few seconds
the thermostat should make a soft click sound. This sound
usually indicates the thermostat is operating properly. If
the thermostat does not click, try the reset operation listed
above. If the thermostat does not click after being reset
contact your heating and cooling service person or place
of purchase for a replacement. If the thermostat clicks,
contact the furnace manufacturer or a HVAC service
person to verify the heating is operating correctly.
No Cool 1. Cooling system requires service or
thermostat requires replacement.
Same as diagnostic for No Heat condition except set the
thermostat to COOL and lower the setpoint below the
room temperature. There may be up to a five minute delay
before the thermostat clicks in Cooling.
Heat, Cool or Fan
Runs Constantly
1. Possible short in wiring.
2. Possible short in thermostat.
3. Possible short in heat/cool/fan system.
4. FAN Switch set to Fan ON.
Check each wire connection to verify they are not shorted
or touching together. No bare wire should stick out from
under terminal block. Try resetting the thermostat as de-
scribed above. If the condition persists the manufacturer
of your system or service person can instruct you on how
to test the Heat/Cool system for correct operation. If the
system operates correctly, replace the thermostat.
Thermostat Setting &
Thermostat Thermometer
Disagree
1. Thermostat thermometer setting
requires adjustment.
The thermometer can be adjusted +/- 4 degrees. See
Temperature Display Adjustment in the Configuration
Menu section.
Furnace (Air Conditioner)
Cycles Too Fast or Too Slow
(narrow or wide
temperature swing)
1. The location of the thermostat and/or
the size of the Heating System may
be influencing the cycle rate.
Digital thermostats provide precise control and cycle
faster than older mechanical models. The system turns
on and off more frequently but runs for a shorter time
so there is no increase in energy use. If you would like
an increased cycle time, choose SL for slow cycle in the
Configuration menu, step 7 (heat) or 8 (cool). If an ac-
ceptable cycle rate is not achieved, contact a local HVAC
service person for additional suggestions.
Forgot Keypad
Lockout Code
Press the menu key (key will disappear) and hold in for
20 seconds. This unlocks the thermostat.
Blank display any or keypad
not responding
1. Voltage Spike or static discharge Use the Reset Operation shown above.
Thermostat does not have
Menu Screen Numbers
1. Earlier version of thermostat To access the earlier version instruction sheet (37-6914E)
go to www.white-rodgers.com, enter 1F95-1291 in Model
Number Search
Reset Operation
Note: If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the
thermostat by removing the thermostat from the wall plate and removing batteries for 2 minutes. After two minutes, replace
the batteries and replace thermostat on wall plate. If the thermostat has been reset and still does not function correctly contact
your heating/cooling service person or place of purchase.
www.white-rodgers.com
www.emersonclimate.com
TROUBLESHOOTING