Avtron LPH100 Compact, Portable Load Bank - 100 KW Testing Your Emergency Standby Generator with a Load Bank Means Reliability When it Matters Most. Key Features • Rated for Continuous Operation • Compact, Portable, Easy to Transport and Operate • Large Load Capacity up to 100 KW • Lightweight Aluminum and Aluminized Steel Enclosure with Casters • Convenient Operator Controls with Digital Metering and Data Logging Software included The Avtron Model LPH100 Load Bank is a portable, selfcontained AC resistive model designed for indoor use. The Avtron LPH00 Load Bank gives users the freedom of a high capacity load in an ultra-compact package. The LPH100 is ideal for routine testing and maintenance of AC power sources such as stand-by-emergency generators and UPS systems. The load bank is rated at 100 KW at 480 VAC and 93.75 KW at 240 VAC at 3 phase, 60 Hz. This versatile load bank weighs only 105 lbs. [48 kg] and is less than half the weight and size of traditional load banks of similar capacity. The load bank features horizontal air discharge to provide a low profile design. Quick-connect load terminals and simple operation allow the load bank to be set up and operated by a single technician, saving valuable time in the field. The load bank controls and cooling fans are powered by any standard 120 VAC, single phase wall outlet with detachable line cord provided. An integral control panel is provided for load bank operation and includes the necessary controls and status indicators. The LPH100 Load Bank features the standard in Digital Metering which includes the Avtron Advanced Digital Monitoring System (ADMS™). The ADMS meter provides faceplate digital display of Volts, Amps, Frequency, and KW. The Communicator EXT™ Data Logging Software allows Real Time Data Acquisition and trending of all meter parameters from your Laptop PC or PDA. An Infrared/USB interface cable is included for “Plug and Play” convenience. Superior Avtron quality combined with simple operation and maintenance will provide years of trouble free service. Avtron’s extensive line of Load Bank and Industrial Resistor Products are solid performers used throughout the world. For total technical support or additional information, please contact Avtron at (216) 573-7600 or LBsales@Emerson.com. Quality System Certified to ISO 9001 LPH100 100 KW Compact, Portable Avtron Load Bank. Avtron LPH100 Compact, Portable Load Bank - 100 KW Specifications subject to change without notice. Construction A compact aluminized steel enclosure with screened inlet and exhaust openings. Four swivel casters provide mobility. Heavy duty lifting handles are also provided. Control Power The load bank requires control power of 120 VAC, single phase, 60 Hz (line cord provided). Cooling Load Capacity Ratings: (3 phase, 60 Hz) Available Load Step Resolution: 5 KW Rated KW Rated Voltage Load Step Resolution 100 480 5, 10, 10, 25, 50 93.75 240 3.75, 7.5, 7.5, 25, 50 NOTE Designs for international 50/60 Hz voltages or custom DC designs are also available. Consult factory. Load Bank Weight (approx.) 105 lbs. [48 kg] Options • 20' cable set with connectors • Heavy duty shipping case The resistive elements are air cooled by four high velocity muffin fans for quiet operation. Controls 16.25 [413.00] The operator control panel includes a MASTER LOAD ON-OFF switch, load step ON-OFF industrial toggle switches, a BLOWER ON-OFF switch, and a LOAD VOLTAGE selector switch (Dual Voltage model only). 14.75 [375.00] CONTROL PANEL 25.16 [638.97] LOAD CONNECTION PANEL GND 120 VAC A B C Digital Metering Avtron Advanced Digital Monitoring System (ADMS™) is provided for display of Volts, Amps, Frequency, and KW. ADMS™ also includes Communicator EXT™ Data Logging Software. 29.12 [740.00] AIR FLOW Safety Circuits The LPH100 Load Bank features main line circuit fusing, wrong voltage protection (Dual Voltage model only), and overtemperature protection. Emerson Network Power Avtron • 6255 Halle Drive, Cleveland, Ohio 44125, U.S.A. 216-573-7600 • FAX: 216-573-5953 • LBsales@Emerson.com EmersonNetworkPower.com/loadbank 2.63 [67.00] All dimensions are in inches [millimeters]. Emerson. Consider it Solved and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. All the other marks are the property of their respective owners. Communicator EXT™ is a trademark of Electro Industries/GaugeTech. ADMS™ is a trademark of Avtron. Specifications subject to change without notice. ©2015 Emerson Network Power Bulletin 428• Rev. G
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Create Date : 2015:03:11 15:43:36-04:00 Metadata Date : 2015:03:11 15:43:52-04:00 Modify Date : 2015:03:11 15:43:52-04:00 Creator Tool : Adobe InDesign CS6 (Windows) Instance ID : uuid:2a7ec0a7-9353-4d7d-93f0-b7c1fc3c5c64 Original Document ID : xmp.did:F97F117407206811A7BA92A099A48037 Document ID : xmp.id:88CFB3E426C8E4118965945E1FA32B33 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:87CFB3E426C8E4118965945E1FA32B33 Derived From Document ID : xmp.did:BCC57CC42694E3118760AF48E2A3E196 Derived From Original Document ID: xmp.did:F97F117407206811A7BA92A099A48037 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2015:03:11 15:43:36-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 2 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools