AC Power Systems
for Business-Critical Continuity

Interceptor ® Active Tracking ® Filter Series
The Ultimate Solution To Power Disturbance Problems

Liebert

®

When You Require The
Ultimate In Surge Protection

In today's world, almost every business depends on

Features That Make The Difference

sensitive microprocessor-based electronics to conduct

The Industry's Best Attenuation Of Voltage
Transients Proprietary Active Tracking sinewave correction
filter continuously provides close voltage control at any
location on the sinewave.

their day to day operations. This means that electric
power line disturbances can disrupt or cripple equipment
causing a major loss in productivity — and money.
Liebert understands this problem and offers a way to
keep these power problems from getting into your
facility in the first place.
The answer is the Liebert Interceptor® Series Active
Tracking® Filter. These series-connected systems
provide the highest level of protection with the lowest
UL 1449 clamping ratings available.
By closely controlling voltage at every location along
the sinewave, our Active Tracking filter technology
protects sensitive electronic equipment from the
potentially damaging effects of low-energy voltage
transients and the ringwaves that follow. The filter also
stores and releases energy to fill and reduce sinewave
spikes and notches.
Proven Performance
High-energy current diversion is handled by the
Interceptor's sophisticated parallel system of computermatched MOV (metal-oxide varistor) arrays. Each array
module is sand-encapsulated and screened to provide
exact current sharing and prevent component
degradation. Our patented, coordinated fusing is UL
Listed for 200kAIC at 600VAC to ensure absolute safety,
yet allow surge current capability to be attenuated.
The Interceptor Series Active Tracking Filter is UL
1449, UL 1283 and CSA Listed. Our manufacturing
facility is ISO 9001 Registered. Surge current ratings are
independently tested, so you can specify a Liebert
product with complete confidence. And we back every
Liebert Interceptor Series filter with the industry's only
five-year warranty for on-site labor.

The Industry's Best Attenuation Of 100 kHz Ringwaves
The Active Tracking filter system minimizes the aftershocks
of voltage transients and the inherent energy storage system
smoothes the sinewave by filling notches and reducing spikes.
Stringent, Independent Testing For Performance
■ UL 1449, UL 1283 and CSA Listed.
■ ANSI/IEEE C62.11, C62.41, C62.45 Categories A, B,
and C3 tested.
■ Independently tested surge current ratings from 100kAmps
to 300kAmps.
■ Life cycle tested: will survive in excess of 12,000 10kAmp
surges per IEEE Category C3.
Engineered For Superior Surge Current Ratings
And Long Life
■ Computerized "smart" array technology for surge protection.
■ Unique sand-packed silver fuse network allows rated surge
current to pass through without fuse operation.
■ Unprecedented redundancy offers expanded mean-timebetween-failure (MTBF).
■ Sinewave tracking EMI/RFI filtering.
■ Fast response time — less than .5 nanoseconds.
■ All modes of protection.
Compatible With All Linear Loads
■ Provides flexibility for a wide range of applications.
Modular Design For Ease Of Customization And Service
■ Enables you to specify an Interceptor system to match the
needs of a specific application. Also allows easy replacement
of surge modules if required.
Sophisticated User-Friendly Diagnostics
■ On-line system monitoring/testing for all suppression
components in all modes of protection.
■ Standard features include: audible alarm, transient
counter, door LEDs indicating unit status, individual
module status LEDs, and Form C dry contacts for
remote system integrity monitoring and indication
of undervoltage, phase and/or power loss.
■ Optional features include: additional seven-digit transient
counter for normal mode, additional Form C dry contacts.
Manufactured To The Most Stringent ISO Quality Standards
■ ISO 9001 registration for design, manufacturing and service.
A Dedicated Service Network Protects You Too
■ Dedicated service network with over 400 Liebert-trained
and authorized technicians.
■ Toll-free service hotline manned 24 x 7.

2

Specifications
Connection Type
Agency Listings
Protection Modes

EMI/RFI Filtering

Response Time
Load Regulation
Enclosure

Series connected
UL 1449, UL 1283, CSA
All modes standard (Line to Neutral,
Line to Ground, Neutral to Ground,
Line to Line); any combination optional
Normal mode — 60 dB maximum from
10 kHz to 500 MHz; Common mode
50 dB maximum from 10 kHz to 500 MHz
less than .5 nanoseconds
1% no load to full load
NEMA 12 standard; options include
NEMA 3R, 4, 4X and caseless for
switchgear applications

Line Frequency
Line Voltage
Temperature
Operating Humidity
Altitude
Audible Noise
Operational Crest Factor
Warranty

47 to 63 Hz
±15% nominal
-40 to +60°C
0 to 95% noncondensing
0 to 18,000 feet
Less than 45 dBa
3.0
10-Years Parts and
5-Years On-Site Labor

F - Diameter

- Optional Features
2.0” MAX
- Standard Features
.50” MAX

A
D

C

E
B

How To Specify The Appropriate Model:
1) Go to Chart A, choose your Current Rating from column one and corresponding Configuration from column two.
2) Follow column two across to column three to determine your Model Number.
3) Refer to Chart B to determine the Voltage Code from the available choices. Substitute the Voltage Code for “XXX.”
(Use the first three digits of the Voltage Code for split phase and three phase configurations).
4) Finally, to complete your model number, go to the last column or (Monitoring Options) and choose the suffix for Standard Features (-06) or
Optional Features (-03).

Chart A - Active Tracking ® Filter Systems
Current
Rating

Configuration

30A
30A
30A
30A
30A
60A
60A
60A
60A
60A
100A
100A
100A
100A
100A
125A
125A
225A
225A
225A
400A
400A
800A
800A
1200A
1200A
2000A
2000A
4000A
4000A

Single Phase L-L
Single Phase L-N
Split Phase
Three Phase Delta
Three Phase Wye
Single Phase L-L
Single Phase L-N
Split Phase
Three Phase Delta
Three Phase Wye
Single Phase L-L
Single Phase L-N
Split Phase
Three Phase Delta
Three Phase Wye
Single Phase L-L
Single Phase L-N
Split Phase
Three Phase Delta
Three Phase Wye
Three Phase Delta
Three Phase Wye
Three Phase Delta
Three Phase Wye
Three Phase Delta
Three Phase Wye
Three Phase Delta
Three Phase Wye
Three Phase Delta
Three Phase Wye

Model Number
(xxx=voltage code)
FXXXL30
FXXXN30
FXXXS30
FXXXD30
FXXXY30
FXXXL60
FXXXN60
FXXXS60
FXXXD60
FXXXY60
FXXXL100
FXXXN100
FXXXS100
FXXXD100
FXXXY100
FXXXL225
FXXXN225
FXXXS225
FXXXD225
FXXXY225
FXXXD400
FXXXY400
FXXXD800
FXXXY800
FXXXD1200
FXXXY1200
FXXXD2000
FXXXY2000
FXXXD4000
FXXXY4000

Surge Current Capability
per phase (L-N or L-L+L-G)
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
100kA
150kA
150kA
150kA
150kA
150kA
150kA
150kA
150kA
150kA
150kA
150kA
150kA
choose 200 or 300 kA
choose 200 or 300 kA
choose 200 or 300 kA
choose 200 or 300 kA
choose 200 or 300 kA
choose 200 or 300 kA
choose 200 or 300 kA
choose 200 or 300 kA

Dimensions
(inches)
A
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
48.0
48.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0

B
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
20.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
24.0
36.0
36.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0
48.0

Chart B - Nominal Voltage Codes
(substitute for “xxx” to complete model number)
Single Phase, 2 wire plus ground
Split Single Phase, 3 wire plus ground
Three Phase Delta, 3 wire plus ground
Three Phase Delta Hi-Leg, 4 wire plus ground
Three Phase Wye, 3 or 4 wire plus ground

C
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
9.0
12.0
12.0
12.0
12.0
20.0
20.0
20.0
20.0
20.0
20.0

D
21.25
21.25
25.25
25.25
25.25
21.25
21.25
25.25
25.25
25.25
31.25
31.25
31.25
31.25
31.25
31.25
31.25
31.25
31.25
31.25
49.25
49.25
-

E
10.0
10.0
14.0
14.0
14.0
10.0
10.0
14.0
14.0
14.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
18.0
30.0
30.0
-

F
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
.44
-

Weight
Lbs.
40
35
45
50
60
40
35
45
50
60
65
60
70
70
80
65
60
70
70
80
275
300
500
530
700
750
875
950
1175
1300

Monitoring
Options
Standard Features Include:
•Audible Alarm,
Transient Counter
• Door LEDs indicating
unit status
• Individual Module
Status LEDs, and
-06
Form C Dry Contacts
for Remote System
Integrity Monitoring
and Indication of
Under Voltage, Phase
and/or Power Loss.
Optional Features Include:
• Additional SevenDigit Transient Counter
for Normal Mode
-03
• Additional Form C
Dry Contacts
NOTES: For configurations not
mentioned, including caseless
units for switchgear applications
and ungrounded delta units,
consult factory. For different levels
of surge current capacity mode
and/or phase, consult factory.
CODE:
L - N = Line to Neutral
L - G = Line to Ground
N - G = Neutral to Ground
L - L = Line to Line
*Valid for 220/380 and
240/415 per IEC.

Example Model Number:
F120Y30-03

100, 110, 120, 230, 240, 277, 346, 400, 480, 600
100/173, 110/190, 120/208 or 240, 230/400, 277/480, 346/600
208, 240, 380, 400, 480, 600
120/240
100/173, 110/190, 120/208, 230/400, *277/480, 346/600

3

Ensuring The High Availability Of
Mission-Critical Data And Applications.

Emerson Network Power, the global leader in enabling business-critical

Liebert Corporation

continuity, ensures network resiliency and adaptability through a family

1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. &
Canada Only)
614 888 0246 Phone (Outside U.S.)
614 841 6022 FAX

of technologies — including Liebert power and cooling technologies —
that protect and support business-critical systems. Liebert solutions employ
an adaptive architecture that responds to changes in criticality, density and
capacity. Enterprises benefit from greater IT system availability, operational
flexibility, and reduced capital equipment and operating costs.

Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111 Phone
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX

liebert.com
Technical Support
607 724 2484 Phone
800 288 6169 Toll-Free
607 722 8713 Fax
While every precaution has been taken to ensure accuracy and
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting
from use of this information or for any errors or omissions.
© 2005 Liebert Corporation. All rights reserved throughout
the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks
of their respective owners.
® Liebert and the Liebert logo are registered trademarks
of the Liebert Corporation.
SL-22006 (R9/05)

Emerson Network Power.
The global leader in enabling business-critical continuity.
AC Power Systems
Connectivity
DC Power Systems

Embedded Power
Inbound Power
Integrated Cabinet Solutions

Printed in USA

EmersonNetworkPower.com
Outside Plant
Precision Cooling
Site Monitoring and Services

Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2005 Emerson Electric Co.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:4c1c0db0-7675-4c21-87d4-110fb485b2ae
Producer                        : QuarkXPress(tm) 6.1
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (*PANTONE 444 C).%%+ (PANTONE Cool Gray 7 C).%%RGBCustomColor: .393 .448 .465 (*PANTONE 444 C).%%+ .552 .562 .575 (PANTONE Cool Gray 7 C).%%EndComments
Create Date                     : 2005:09:28 13:14:16Z
Creator Tool                    : QuarkXPress(tm) 6.1
Modify Date                     : 2005:10:04 11:51:41-04:00
Metadata Date                   : 2005:10:04 11:51:41-04:00
Document ID                     : uuid:617e35c3-3043-11da-9588-000a95b4c592
Format                          : application/pdf
Title                           : >Nfinity.R2
Creator                         : QuarkXPress(tm) 6.1
EXIF Metadata provided by EXIF.tools

Navigation menu