AC Power Systems for Business-Critical Continuity Interceptor ® Active Tracking ® Filter Series The Ultimate Solution To Power Disturbance Problems Liebert ® When You Require The Ultimate In Surge Protection In today's world, almost every business depends on Features That Make The Difference sensitive microprocessor-based electronics to conduct The Industry's Best Attenuation Of Voltage Transients Proprietary Active Tracking sinewave correction filter continuously provides close voltage control at any location on the sinewave. their day to day operations. This means that electric power line disturbances can disrupt or cripple equipment causing a major loss in productivity — and money. Liebert understands this problem and offers a way to keep these power problems from getting into your facility in the first place. The answer is the Liebert Interceptor® Series Active Tracking® Filter. These series-connected systems provide the highest level of protection with the lowest UL 1449 clamping ratings available. By closely controlling voltage at every location along the sinewave, our Active Tracking filter technology protects sensitive electronic equipment from the potentially damaging effects of low-energy voltage transients and the ringwaves that follow. The filter also stores and releases energy to fill and reduce sinewave spikes and notches. Proven Performance High-energy current diversion is handled by the Interceptor's sophisticated parallel system of computermatched MOV (metal-oxide varistor) arrays. Each array module is sand-encapsulated and screened to provide exact current sharing and prevent component degradation. Our patented, coordinated fusing is UL Listed for 200kAIC at 600VAC to ensure absolute safety, yet allow surge current capability to be attenuated. The Interceptor Series Active Tracking Filter is UL 1449, UL 1283 and CSA Listed. Our manufacturing facility is ISO 9001 Registered. Surge current ratings are independently tested, so you can specify a Liebert product with complete confidence. And we back every Liebert Interceptor Series filter with the industry's only five-year warranty for on-site labor. The Industry's Best Attenuation Of 100 kHz Ringwaves The Active Tracking filter system minimizes the aftershocks of voltage transients and the inherent energy storage system smoothes the sinewave by filling notches and reducing spikes. Stringent, Independent Testing For Performance ■ UL 1449, UL 1283 and CSA Listed. ■ ANSI/IEEE C62.11, C62.41, C62.45 Categories A, B, and C3 tested. ■ Independently tested surge current ratings from 100kAmps to 300kAmps. ■ Life cycle tested: will survive in excess of 12,000 10kAmp surges per IEEE Category C3. Engineered For Superior Surge Current Ratings And Long Life ■ Computerized "smart" array technology for surge protection. ■ Unique sand-packed silver fuse network allows rated surge current to pass through without fuse operation. ■ Unprecedented redundancy offers expanded mean-timebetween-failure (MTBF). ■ Sinewave tracking EMI/RFI filtering. ■ Fast response time — less than .5 nanoseconds. ■ All modes of protection. Compatible With All Linear Loads ■ Provides flexibility for a wide range of applications. Modular Design For Ease Of Customization And Service ■ Enables you to specify an Interceptor system to match the needs of a specific application. Also allows easy replacement of surge modules if required. Sophisticated User-Friendly Diagnostics ■ On-line system monitoring/testing for all suppression components in all modes of protection. ■ Standard features include: audible alarm, transient counter, door LEDs indicating unit status, individual module status LEDs, and Form C dry contacts for remote system integrity monitoring and indication of undervoltage, phase and/or power loss. ■ Optional features include: additional seven-digit transient counter for normal mode, additional Form C dry contacts. Manufactured To The Most Stringent ISO Quality Standards ■ ISO 9001 registration for design, manufacturing and service. A Dedicated Service Network Protects You Too ■ Dedicated service network with over 400 Liebert-trained and authorized technicians. ■ Toll-free service hotline manned 24 x 7. 2 Specifications Connection Type Agency Listings Protection Modes EMI/RFI Filtering Response Time Load Regulation Enclosure Series connected UL 1449, UL 1283, CSA All modes standard (Line to Neutral, Line to Ground, Neutral to Ground, Line to Line); any combination optional Normal mode — 60 dB maximum from 10 kHz to 500 MHz; Common mode 50 dB maximum from 10 kHz to 500 MHz less than .5 nanoseconds 1% no load to full load NEMA 12 standard; options include NEMA 3R, 4, 4X and caseless for switchgear applications Line Frequency Line Voltage Temperature Operating Humidity Altitude Audible Noise Operational Crest Factor Warranty 47 to 63 Hz ±15% nominal -40 to +60°C 0 to 95% noncondensing 0 to 18,000 feet Less than 45 dBa 3.0 10-Years Parts and 5-Years On-Site Labor F - Diameter - Optional Features 2.0” MAX - Standard Features .50” MAX A D C E B How To Specify The Appropriate Model: 1) Go to Chart A, choose your Current Rating from column one and corresponding Configuration from column two. 2) Follow column two across to column three to determine your Model Number. 3) Refer to Chart B to determine the Voltage Code from the available choices. Substitute the Voltage Code for “XXX.” (Use the first three digits of the Voltage Code for split phase and three phase configurations). 4) Finally, to complete your model number, go to the last column or (Monitoring Options) and choose the suffix for Standard Features (-06) or Optional Features (-03). Chart A - Active Tracking ® Filter Systems Current Rating Configuration 30A 30A 30A 30A 30A 60A 60A 60A 60A 60A 100A 100A 100A 100A 100A 125A 125A 225A 225A 225A 400A 400A 800A 800A 1200A 1200A 2000A 2000A 4000A 4000A Single Phase L-L Single Phase L-N Split Phase Three Phase Delta Three Phase Wye Single Phase L-L Single Phase L-N Split Phase Three Phase Delta Three Phase Wye Single Phase L-L Single Phase L-N Split Phase Three Phase Delta Three Phase Wye Single Phase L-L Single Phase L-N Split Phase Three Phase Delta Three Phase Wye Three Phase Delta Three Phase Wye Three Phase Delta Three Phase Wye Three Phase Delta Three Phase Wye Three Phase Delta Three Phase Wye Three Phase Delta Three Phase Wye Model Number (xxx=voltage code) FXXXL30 FXXXN30 FXXXS30 FXXXD30 FXXXY30 FXXXL60 FXXXN60 FXXXS60 FXXXD60 FXXXY60 FXXXL100 FXXXN100 FXXXS100 FXXXD100 FXXXY100 FXXXL225 FXXXN225 FXXXS225 FXXXD225 FXXXY225 FXXXD400 FXXXY400 FXXXD800 FXXXY800 FXXXD1200 FXXXY1200 FXXXD2000 FXXXY2000 FXXXD4000 FXXXY4000 Surge Current Capability per phase (L-N or L-L+L-G) 100kA 100kA 100kA 100kA 100kA 100kA 100kA 100kA 100kA 100kA 150kA 150kA 150kA 150kA 150kA 150kA 150kA 150kA 150kA 150kA 150kA 150kA choose 200 or 300 kA choose 200 or 300 kA choose 200 or 300 kA choose 200 or 300 kA choose 200 or 300 kA choose 200 or 300 kA choose 200 or 300 kA choose 200 or 300 kA Dimensions (inches) A 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 48.0 48.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 60.0 B 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 20.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 24.0 36.0 36.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 48.0 Chart B - Nominal Voltage Codes (substitute for “xxx” to complete model number) Single Phase, 2 wire plus ground Split Single Phase, 3 wire plus ground Three Phase Delta, 3 wire plus ground Three Phase Delta Hi-Leg, 4 wire plus ground Three Phase Wye, 3 or 4 wire plus ground C 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 9.0 12.0 12.0 12.0 12.0 20.0 20.0 20.0 20.0 20.0 20.0 D 21.25 21.25 25.25 25.25 25.25 21.25 21.25 25.25 25.25 25.25 31.25 31.25 31.25 31.25 31.25 31.25 31.25 31.25 31.25 31.25 49.25 49.25 - E 10.0 10.0 14.0 14.0 14.0 10.0 10.0 14.0 14.0 14.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 30.0 30.0 - F .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 .44 - Weight Lbs. 40 35 45 50 60 40 35 45 50 60 65 60 70 70 80 65 60 70 70 80 275 300 500 530 700 750 875 950 1175 1300 Monitoring Options Standard Features Include: •Audible Alarm, Transient Counter • Door LEDs indicating unit status • Individual Module Status LEDs, and -06 Form C Dry Contacts for Remote System Integrity Monitoring and Indication of Under Voltage, Phase and/or Power Loss. Optional Features Include: • Additional SevenDigit Transient Counter for Normal Mode -03 • Additional Form C Dry Contacts NOTES: For configurations not mentioned, including caseless units for switchgear applications and ungrounded delta units, consult factory. For different levels of surge current capacity mode and/or phase, consult factory. CODE: L - N = Line to Neutral L - G = Line to Ground N - G = Neutral to Ground L - L = Line to Line *Valid for 220/380 and 240/415 per IEC. Example Model Number: F120Y30-03 100, 110, 120, 230, 240, 277, 346, 400, 480, 600 100/173, 110/190, 120/208 or 240, 230/400, 277/480, 346/600 208, 240, 380, 400, 480, 600 120/240 100/173, 110/190, 120/208, 230/400, *277/480, 346/600 3 Ensuring The High Availability Of Mission-Critical Data And Applications. Emerson Network Power, the global leader in enabling business-critical Liebert Corporation continuity, ensures network resiliency and adaptability through a family 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX of technologies — including Liebert power and cooling technologies — that protect and support business-critical systems. Liebert solutions employ an adaptive architecture that responds to changes in criticality, density and capacity. Enterprises benefit from greater IT system availability, operational flexibility, and reduced capital equipment and operating costs. Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX liebert.com Technical Support 607 724 2484 Phone 800 288 6169 Toll-Free 607 722 8713 Fax While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. © 2005 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice. All names referred to are trademarks or registered trademarks of their respective owners. ® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. SL-22006 (R9/05) Emerson Network Power. The global leader in enabling business-critical continuity. AC Power Systems Connectivity DC Power Systems Embedded Power Inbound Power Integrated Cabinet Solutions Printed in USA EmersonNetworkPower.com Outside Plant Precision Cooling Site Monitoring and Services Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2005 Emerson Electric Co.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 4 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:4c1c0db0-7675-4c21-87d4-110fb485b2ae Producer : QuarkXPress(tm) 6.1 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (*PANTONE 444 C).%%+ (PANTONE Cool Gray 7 C).%%RGBCustomColor: .393 .448 .465 (*PANTONE 444 C).%%+ .552 .562 .575 (PANTONE Cool Gray 7 C).%%EndComments Create Date : 2005:09:28 13:14:16Z Creator Tool : QuarkXPress(tm) 6.1 Modify Date : 2005:10:04 11:51:41-04:00 Metadata Date : 2005:10:04 11:51:41-04:00 Document ID : uuid:617e35c3-3043-11da-9588-000a95b4c592 Format : application/pdf Title : >Nfinity.R2 Creator : QuarkXPress(tm) 6.1EXIF Metadata provided by EXIF.tools