Emerson Bms Battery Monitoring System Brochures And Data Sheets PDS1
2015-03-30
: Emerson Emerson-Bms-Battery-Monitoring-System-Brochures-And-Data-Sheets-680016 emerson-bms-battery-monitoring-system-brochures-and-data-sheets-680016 emerson pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Chloride BMS Industrial Power for Business-Critical Continuity™ Battery Monitoring System Chloride BMS is a battery monitoring tool to effectively manage stand-by battery banks, thereby ensuring the reliability of back-up power systems. It helps minimizing the risk of failure to critical systems. BMS enables maintenance teams to easily monitor battery health status and resolve potential issues before they become costly problems. Benefits Reduced maintenance costs through preventive maintenance instead of emergency replacement Maximized battery life through smart diagnostics, regular data analysis and ontime remedial action Increased safety on site as back-up power remains available when most needed and less human presence is required in battery room Key Features 24/7 alarm notification Event Log of all activities affecting the battery bank Remote access – via TCP/IP or Modbus Automatic capture of data and report generation Individual battery impedance measure Individual and ambient battery temperature measures Individual and battery string voltage and current measures Compatible with Ni-Cd and Lead batteries, open or gas-recombination types Optical isolation to increase safety Wide choice of configurations to meet the most complex architectures Applications Chloride BMS suits all applications where safety and reliance on a battery bank is highly critical: Oil and Gas, Petrochemical and Chemical industries Power generation plants Power Transmission and Distribution Continuous process industries The power to predict battery health Chloride BMS battery monitoring system is the ultimate detection tool to predict and detect stand-by battery bank issues. Routine testing is essential to evaluate performance of any battery. The Chloride BMS continuous monitoring tool allows preventive detection of any potential anomaly: all the relevant parameters, such as voltages, current, impedance and temperature are constantly measured to allow a secure diagnostic of the battery health status. A wide scope of communication features such as emailing, SMS and serial link allows the maintenance manager to get the right information early enough to prevent power failures. By using the Link dedicated software, the user can access to real time battery status and measurements, view alarm and battery history and check alarm status of all connected cells. It is also possible to initiate and manage battery dedicated reports. Chloride BMS Chloride BMS Box - technical data Purpose The Chloride BMS box is a wall-mounted box to interconnect the monitored battery with the monitoring software tool and which allows remote indication via serial link and volt-free contacts. General Data Power supply voltage range 48VDC - 400VDC (from battery) Dimensions Height: 560mm Width: 585mm Depth: 400mm Ingress protection Frame colour Cable entry Operating temperature Storage temperature Communication Relay outputs (volt-free contacts) IP42 according to IEC60529 Grey RAL 7032 Bottom 0°C to 50°C 0°C to 70°C Com port 1 Com port 2 Ethernet RS 485 interface: Modbus ASCII or RTU protocol -Voltage fault -Temperature fault -Impedance fault -System fault Sentinel data acquisition module - technical data Purpose The Sentinel module allows to measure string values and makes data acquisition from the connected m-Senzors. Battery string measured values String voltage range 2V - 600V String current: •Measurement Range 0A - 2000A •Number of string current measures up to 5 (scaleable to 16) String ambient temperature: •Measurement range 0°C to 50°C •Number of measures up to 5. Only 1 sensor per battery room if several strings in the same battery room Acquisition of battery monoblock measured values (1) Number of monoblocks up to 160 (scaleable to 1280) Voltage (depending on battery type and m-Senzor type) from 1V to 12V (2) Impedance (depending on block voltage and m-Senzor) from 0.15 to 40 mΩ - For Lead Acid batteries ONLY Temperature(2) from -10°C to +70°C General Data Power supply voltage range 48 VDC - 110 VDC Dimensions Height: 270mm (1U) Width: 430mm Depth: 45mm Chloride BMS box Sentinel module Communication LEDs 12 status LEDs on front of the module Service port RS232 for configuration / factory setting) Digital inputs 4 (1) A monoblock represents one or more battery cells in a container. (2) Available as option. m-Senzor module technical data Purpose m-Senzor is the measurement module which can measure individual monoblock voltage, impedance and temperature. Application Lead Acid or Nickel-Cadmium Vented or Recombination Measurements Input configuration Single or Dual monoblocks sensors Nominal voltage 1V 2V 4V 6V 8V 12 V Voltage measure 0.8V - 1.9V 1.6V - 2.6V 3.2V - 5.2V 4.8V - 7.8V 6.4V - 10.4V 9.6V - 15.6V Impedance measure 0.15 - 5 mΩ 0.15 - 5 mΩ 0.15 - 5 mΩ 0.5 - 20 mΩ 0.5 - 20 mΩ 1 - 40 mΩ Temperature measure -10°C to +70°C (measure taken on negative post of battery) General Data Power supply powered by the monoblocks being monitored Interface to Sentinel BBUS (150m max cable length per BBUS port) m-Senzor module Link Battery Management Software Purpose Link is the battery management software which allows easy interfacing and understanding of battery status and alarms Recommended PC system requirements (3) Processor Intel E5400 DUAL CORE or better Operating system Windows XP Professional or greater RAM 2 GB (3) PC is not part of our scope of supply. Emerson Network Power. The global leader in enabling Business-Critical Continuity™. Link software screenshot AC Power Embedded Power Power Switching & Controls Connectivity Industrial Power Precision Cooling DC Power Infrastructure Management & Monitoring Racks & Integrated Cabinets Embedded Computing Outside Plant Services Emerson Network Power IS S.A.S 30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex - France T: +33 (0)4 78 40 13 56 F: +33(0)4 78 90 58 90 Industrial.sales.Chloride@Emerson.com EmersonNetworkPower.com Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2012 Emerson Electric Co. BMS-DSUK-Rev0-12/2012 While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Industrial Power for Business-Critical Continuity™ Battery Monitoring System
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 2 Page Layout : SinglePage XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:22a905a9-fdde-458b-8401-a4d8307b3235 Producer : Acrobat Distiller 6.0 (Windows) Create Date : 2013:01:11 11:06:03+01:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:01:11 11:07:25+01:00 Metadata Date : 2013:01:11 11:07:25+01:00 Document ID : uuid:68ef74a5-3f0b-4e77-80fb-cd73fec4fdac Format : application/pdf Creator : NLE Title : BMS PDS1.indd Author : NLEEXIF Metadata provided by EXIF.tools