Emerson Chloride Cp 60Z 5 To 60 Kva Brochures And Data Sheets

2015-03-30

: Emerson Emerson-Chloride-Cp-60Z-5-To-60-Kva-Brochures-And-Data-Sheets-680012 emerson-chloride-cp-60z-5-to-60-kva-brochures-and-data-sheets-680012 emerson pdf

Open the PDF directly: View PDF PDF.
Page Count: 2

DownloadEmerson Emerson-Chloride-Cp-60Z-5-To-60-Kva-Brochures-And-Data-Sheets-  Emerson-chloride-cp-60z-5-to-60-kva-brochures-and-data-sheets
Open PDF In BrowserView PDF
Chloride CP-60Z AC UPS System

Industrial Power for
Business-Critical Continuity™

5 to 60kVA - 1ph and 3ph output

The Chloride CP-60Z industrial
Uninterruptible Power Supply (UPS)
system is the result of latest industrial
requirements combined with R&D
innovations to offer an improved
efficiency and reduced operating costs
industrial UPS.
The Chloride CP range is designed to meet
the stringent electrical and mechanical
requirements in industrial environments.
Each Chloride CP product is based on interchangeable sub-assemblies to allow full
customization, in compliance with client’s
technical specification and with project
documentation requirements.

Benefits
 Energy savings - Improved efficiency means
reduced power consumption and smaller air
conditioning system
 Project savings - Higher input power factor and
lower inrush current allow smaller upstream
transformer, switchgear and cables and reduce
line current and losses in the cables.
 Safe and easy maintenance - Segregated
manual bypass and front access to major components improve safety and reduce MTTR
 Asset Management System - The UPS is compatible with the Emerson AMS Suite Intelligent
Device Manager which helps to ensure an
efficient preventive maintenance

Key Features
 Low Ripple Voltage to reduce battery stress
and optimize its lifetime
 Low inrush current < 4In (12-pulse) not to
oversize mains power supply
 SCR-based rectifier, 6 or 12 pulses, with
improved operation to significantly reduce
the mains’ pollution (THDi) and the input RMS
current
 Proven reliability: The unique design allows
the UPS to continuously operate at full load at a
permanent 40°C ambient temperature
 Galvanic isolation: input and output transformers are standard on the complete range.
 Ingress protection IP42 is provided as
standard to operate in the most demanding
environments
 Compatibility with Nickel-Cadmium and LeadAcid batteries, open or gas-recombination
types
 Multilingual digital graphic display with
embedded event log
 Wide choice of configurations, options, and
remote monitoring solutions

Applications
The Chloride CP-60Z is the best solution, both
cost effective and environmental friendly, to meet
industrial requirements of a wide range of sectors,
such as:
 Oil & Gas, offshore and onshore
 Refining and Petrochemical industries
 Water infrastructures
 Mining
 Transportation (rail, metro, tramway)

Custom-designed AC UPS systems to secure industrial processes
The Chloride CP-60Z is available from 5 to 60kVA in single-phase or three-phase
output configuration. It offers a wide choice of DC battery voltages (110V, 220V
or 400V) and of output voltages (from 1x110 V to 3x415V) to best fit the application.
The UPS uses patented digital Vector Control technology which increases the UPS
performances, enables active conditioning of the load and allows personalised
system settings.
The Chloride CP-60Z can be adapted for project-specific requirements. A wide
choice of industrialized extras allow system customization according to the most
demanding technical specifications.
To further improve load availability and process reliability, the system is able to
operate in dual parallel configuration, centralized or distributed, with single or
dual batteries, and can include AC bus-tie.

Chloride CP-60Z AC UPS System

Ratings - Output Power at cos phi 0.8 (kVA) vs battery voltage (Vdc)
110-120 Vdc
5
10
20
30
-

220-240 Vdc
5
10
20
30
40
50
60

Standards
400 Vdc
40
50
60

Technical Data
Input
Input voltage (other voltage on request)
Inrush current
Power factor
Frequency range
Intermediate DC circuit
Nominal DC voltage
Voltage stability
Voltage ripple (battery connected)
Current limitation
Charging characteristic
Output
Available ratings (see table above)
AC voltage:
•	Single phase
•	Three phase
Frequency
Frequency stability:
•	with internal oscillator
•	with reserve synchronism
Voltage stability (0-100% load variation):
•	static
•	dynamic
Overload inverter (in % of nominal power)
Short-circuit clearance:
•	1-ph output (in % of nominal current)
•	3-ph output (in % of nominal current)
Voltage distorsion:
with 100% linear load
with 100% non linear load
Allowable power factor
Allowable crest factor
Battery
Type
Autonomy
Battery current limitation
General Data
Rectifier efficiency
Operating temperature
Storage temperature
Relative humidity
Operating altitude
Cooling
External ingress protection
Noise
Input / output isolation
Frame colour
Dimensions

Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.

Compliance

IEC 62040 (-1, -2, -3) / 60146 (-1-1, -1-3, -2) / IEC 60950
IEC 61000-6-2 - IEC 61000-6-4
IEC 60529 / IEC 60439 / IEC 60076

Conformity

EMC Directive 2004/108/CE
Low Voltage Directive (LVD) 2006/95/CE
CE Mark

Options
Rectifier
400 VAC (380; 415) ±10%
< 8 x In (6-pulse version)
< 4 x In (12-pulse version)
up to 0.94
50 Hz (60 Hz factory setting) ±5%
110 / 120 / 220 / 240 / 400 VDC
±1% in float mode, input within tolerance
±1.5% for parallel chargers
0.25% RMS, in float mode
I nominal
IU according to DIN 41773

Battery

Output
Reserve

from 5 to 60 kVA (at PF 0.8 lagging)
230 VAC (220, 240) ; 110 VAC (115, 120)
400 VAC (380, 415) ; 220 VAC (190, 208)

System

50 Hz (60 Hz factory setting)
±0.05%
±3% (from 0.2 to 6% factory setting)
±1% (±2% for parallel systems)
VFI SS 111 - complies to IEC62040-3, class 1

Mechanical

150%/1 min - 125%/10 min
250%/100 ms - 175%/5 s
315%/100 ms - 220%/5 s (Ph-N)
<3 %
≤5 % (complies with IEC 62040-1-2)

Communication

0.5 lagging to 0.5 leading
3/1
Lead Acid or Nickel Cadmium,
vented or recombination
From few minutes to several hours,
as required and specified
0.1C (lead acid) / 0.2C (Nickel Cadmium)
up to 90 % (according to rating and config.)
From 0 to 40 °C
From -20 °C to +70 °C (battery excluded)
<90 % non condensing at 20 °C
1000 m (without system derating)
Fan-assisted with redundant monitored fans
IP 42
less than 66 dB (according to rating)
2500 VAC / 1 minute
RAL 7032
Varying according to ratings and options

12-pulse SCR rectifier
Special 3-ph input voltage (up to 3x690Vac)
Surge and/or lighning protections
Input circuit breaker
Battery circuit protection box (Fuse or circuit breaker)
Battery reversed polarity detection
Battery Low Voltage Disconnection (LVD)
Battery black start
Battery room temperature sensor for battery charge compensation
DC earth fault detection
AC earth fault detection
Output fuse switch or circuit breaker
Reserve input circuit breaker
Reserve transformer (H class)
Reserve stabilizer (servo-controlled)
Stabilizer output isolator
Dual configurations
AC distribution (circuit breakers)
Backfeed protection
Internal cabinet lighting
Auxiliary power socket
Anti-condensation heater
UPS cabinet temperature monitor
Special cabinet identification (Tag, nameplate)
Top cable entry
Special frame color
Special feet height
Special keylock
Special gland plate
Lifting eyes
2mm panels thickness
Front panel analogue meters (72x72, class 1 or class 1.5)
Transducers 4-20mA
Additional volt-free contacts
Modbus RTU (RS232 or RS485)
Modbus / TCP
Profibus
IEC61850 protocol
PPVis monitoring software
AMS compatibility kit
Passive mimic panel
Active mimic panel with integrated LEDs
Special lamp indicator on front panel (22mm diameter)

AC Power

Embedded Power

Power Switching & Controls

Connectivity

Industrial Power

Precision Cooling

DC Power

Infrastructure Management & Monitoring

Racks & Integrated Cabinets

Embedded Computing

Outside Plant

Services

Emerson Network Power IS S.A.S
30 avenue Montgolfier - BP90 - 69684 Chassieu Cedex - France
T: +33 (0)4 78 40 13 56 F: +33(0)4 78 90 58 90
Industrial.sales.Chloride@Emerson.com
EmersonNetworkPower.com

Emerson, Business-Critical Continuity and
Emerson Network Power are trademarks of
Emerson Electric Co. or one of its affiliated companies.
©2013 Emerson Electric Co.
CP60Z-DSUK-Rev0-01/2013

While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network Power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

Industrial Power for
Business-Critical Continuity™

5 to 60 kVA - 1 ph and 3ph output



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.2-c003 61.141987, 2011/02/22-12:03:51
Create Date                     : 2013:03:14 11:13:35+01:00
Metadata Date                   : 2013:03:14 11:13:41+01:00
Modify Date                     : 2013:03:14 11:13:41+01:00
Creator Tool                    : Adobe InDesign CS5.5 (7.5)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 10593 bytes, use -b option to extract), (Binary data 11980 bytes, use -b option to extract)
Instance ID                     : uuid:1788ee0a-2f1b-4b8c-8752-dd4797840831
Original Document ID            : xmp.did:77357CAC7A35E211922EFD14297DBD11
Document ID                     : xmp.did:26118FB0828CE2118380A5E9DA124AA7
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:77357CAC7A35E211922EFD14297DBD11, xmp.iid:7B357CAC7A35E211922EFD14297DBD11, xmp.iid:7FA291288235E211922EFD14297DBD11, xmp.iid:83A291288235E211922EFD14297DBD11, xmp.iid:E9E8E05A3D3AE211800BF1E10407055C, xmp.iid:D9366C692445E2118E74CCC162592B5F, xmp.iid:DF366C692445E2118E74CCC162592B5F, xmp.iid:E5ED054BBA49E211ABA7CFFFC62A6B3F, xmp.iid:229E164BBA49E211ABA7CFFFC62A6B3F, xmp.iid:F7C0F717F849E211ABA7CFFFC62A6B3F, xmp.iid:1BC58A722D50E211B5318735FBA2E623, xmp.iid:6E49D2722D50E211B5318735FBA2E623, xmp.iid:461DBC14E460E211B524B94489D39B44, xmp.iid:C6B02B523965E211B900C3774EDF04FE, xmp.iid:CEB02B523965E211B900C3774EDF04FE, xmp.iid:CA845304B16BE211AE60CC53E77A4E6E, xmp.iid:B75179CAB16BE211AE60CC53E77A4E6E, xmp.iid:C3F53B9FD26EE211862AE25754577976, xmp.iid:2D118FB0828CE2118380A5E9DA124AA7, xmp.iid:2E118FB0828CE2118380A5E9DA124AA7
History When                    : 2012:11:23 15:51:42+01:00, 2012:11:23 16:26:31+01:00, 2012:11:23 16:26:31+01:00, 2012:11:23 16:36:08+01:00, 2012:11:29 16:56:36+01:00, 2012:12:13 13:55:46+01:00, 2012:12:13 13:55:46+01:00, 2012:12:19 09:58:44+01:00, 2012:12:19 09:58:44+01:00, 2012:12:19 17:21:07+01:00, 2012:12:27 14:58:09+01:00, 2012:12:27 14:58:10+01:00, 2013:01:17 21:25:49+01:00, 2013:01:23 09:46:04+01:00, 2013:01:23 09:46:04+01:00, 2013:01:31 15:23:32+01:00, 2013:01:31 15:23:32+01:00, 2013:02:04 14:56:06+01:00, 2013:03:14 09:46:28+01:00, 2013:03:14 09:46:28+01:00
History Software Agent          : Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign CS6 (Windows), Adobe InDesign 7.5, Adobe InDesign 7.5
History Changed                 : /, /metadata, /, /, /metadata, /, /metadata, /, /, /metadata, /, /, /metadata, /, /metadata, /, /, /;/metadata, /metadata
Derived From Instance ID        : xmp.iid:CA845304B16BE211AE60CC53E77A4E6E
Derived From Document ID        : xmp.did:CEB02B523965E211B900C3774EDF04FE
Derived From Original Document ID: xmp.did:77357CAC7A35E211922EFD14297DBD11
Derived From Rendition Class    : default
Doc Change Count                : 3
Key Stamp Mp                    : AAAAAA==
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS5.5 (7.5)
EXIF Metadata provided by EXIF.tools

Navigation menu