Fisherr1061 Pneumatic Piston Rotary
Actuator
Fisher 1061 pneumatic piston rotary actuators are
used to operate splined-shaft rotary control valves
such as Vee-Balltvalves, eccentric disc valves, and
butterfly valves. The actuator/valve body linkage of
this actuator can be positioned for either
push-down-to-open or push-down-to-close action.
Additionally, the 1061 actuator can be used with a
two-position control signal for on-off service or with a
valve positioner for throttling service. An optional
handwheel actuator is also available to allow for
auxiliary or emergency manual valve operation when
the 1061 piston actuator is not in use. For complete
information on the valve positioner and the manual
handwheel actuator, refer to the appropriate bulletin.
Features
Application Flexibility–Actuator is available in
push-down-to-open or push-down-to-close
construction and may be mounted in any of four
actuator/valve body mounting positions (see figure
2).
Minimal Dead Band–Single-point linkage with
splined and clamped lever minimizes lost motion
and improves control accuracy.
Compact Construction–Compared to similar
actuators, overall size is reduced by as much as 30
percent.
1061 Actuator with FIELDVUE™ DVC6200 Digital Valve
Controller Mounted on a Fisher V500 Valve
W8380-2
Long Service Life–Rugged construction provides
stability, corrosion resistance, and protection from
deformation should the actuator be over-pressured.
Accessibility–Actuator/valve body linkage is
completely enclosed, yet the valve packing
adjustment remains accessible without removing
any parts.
Monitoring Ease–Highly visible travel indicator
allows easy determination of valve position.
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
2
Specifications
Available Configuration
Actuator Sizes: J30, J40, J60, J68, J80,
J100, and J130
Action: Double-acting pneumatic piston rotary
actuator for Jthrottling service when used with
positioner, or Jon-off service when used with
switching devices
Cylinder Operating Pressure
Minimum Recommended: J1.4 bar (20 psig)
without positioner, or J0.35 bar (5 psi) above
actuator requirement with positioner(1).
Maximum Allowable(2)
Sizes 30 and 60: 6.9 bar (100 psig)
Size 40: 10.3 bar (150 psig)
Size 68: 5.9bar(85psig)
Size 80: 10.3 bar (150 psig)
Size 100: 10.3 bar (150 psig)
Size 130: 10.3 bar (150 psig)
Valve Shaft Diameters, mm (Inch)
Size 30: J12.7 (1/2), J15.9 (5/8),J19.1 (3/4),
J22.2 (7/8), J25.4 (1), and J31.8 (1-1/4)
Sizes 40, 60, and 68: J19.1 (3/4), J22.2 (7/8),
J25.4 (1), J31.8 (1-1/4), J38.1 (1-1/2), J44.5
(1-3/4), and J50.8 (2)
Sizes 80 and 100: J44.5 (1-3/4), J50.8 (2), and
J63.5 (2-1/2)
Size 130: J76.2 (3) and J88.9 (3-1/2)
Maximum Valve Shaft Rotation
J90 degrees without travel stop or J60 degrees
with optional travel stop
Maximum Breakout Torque(1)
Size 30: Up to 282 NSm (2500 lbfSin)
Size 40: Up to 847 NSm (7500 lbfSin)
Size 60: Up to 1130 NSm (10,000 lbfSin)
Size 68: Up to 1540 NSm (13,600 lbfSin)
Size 80: Up to 5080 NSm (45,000 lbfSin)
Size 100: Up to 6290 NSm (55,700 lbfSin) with 63.5
mm (2-1/2 in.) valve shaft diameter
Size 130: Up to 19,800 NSm (175,000 lbfSin)
Stroking Time
Dependent on actuator size, rotation, and positioner
if used. If stroking time is critical, consult your
Emerson Process Management sales office.
Construction Materials
Cylinder and Cylinder Flange: Aluminum
Housing Cover: JCast iron or Jaluminum (only for
size 130)
Piston: JAluminum or JNylon-coated piston
(optional only for sizes 30 to 100)
Piston Rod: Chrome-plated stainless steel
Lever: Ductile iron
Sliding Seal: Aluminum
O-Rings: Nitrile
Housing:
Sizes 30, 40, 60, and 68: Cast iron
Sizes 80, 100 and 130: Aluminum
Mounting Yoke: Cast iron
Mounting Yoke Bushing: PTFE and steel
Material Temperature Capabilities with Standard
Elastomers(2)
-34 to 82_C(-30to180_F)
Pressure Connections
1/4 NPT internal, and for optional pipe-away vent,
3/4 NPT internal connection
Size 130 uses 1 NPT internal connection. See table 1
Travel Indication
Graduated scale and pointer located on actuator end
of valve shaft
Mounting Positions
Seefigure2
Approximate Weight
See table 2
1. Actual actuator torque available depends on specific construction and casing pressure. For information on torque requirements of the valve being considered, contact your Emerson Process
Management sales office.
2. The pressure/temperature limits in this manual and any applicable standard or code limitation for actuator should not be exceeded.
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
3
Figure 1. Sectional of Fisher 1061 Actuator
W3827-1 W2288-3
Table 1. Displacement for 90 Degree Rotation
SIZE PISTON DOWN PISTON UP
cm3Inch3cm3Inch3
30
40
60
68
80
100
130
1100
2130
4060
7210
13,000
19,100
41,100
67
130
248
440
794
1165
2508
1200
2230
4380
7110
12,900
18,800
40,200
74
136
267
434
788
1150
2454
Table 2. Approximate Weight
ACTUATOR SIZE kg Lb
30
40
60
68
80
100
130
22
29
39
56
122
135
299
49
63
86
123
246
298
660
Options
Pneumatic Instruments: J3710, J3610JP, or
J3620JP pneumatic or electro-pneumatic positioners
or JFIELDVUE DVC6200 Digital Valve Controllers are
available. Also, the 377 Series trip valves are available
with Jlock-in-last position, Jfail-up, or Jfail-down
action (for specifications, see separate bulletins).
Potentiometer: It is used for remote valve rotation
indication.
Limit Switches: JTopWorx™ DXP M21GNEB limit
switch for one through six single-pole, double-throw
contacts (see separate bulletin), JGOtproximity
switches for one or two single-pole, double-throw
contacts, or JMicro-Switches or NAMCO switches for
one or two single-pole, double-throw or double-pole,
double-throw contacts. GO proximity switch are not
available for size 80, 100 or 130 actuators.
Handwheel Actuator: The Fisher 1078 manual
declutchable actuator (see figure 3) allows auxiliary or
emergency valve operation of sizes 30 through 100
when engaged (see bulletin 61.8:1078).
Cylinder Bypass: The bypass valve is required when a
handwheel actuator is specified.
Locking Mechanism: The locking mechanism shown in
figure 4 is available for sizes J30, J40, J60, and
J68 actuators. The locking mechanism shown in
figure 5 is available for sizes J80 and J100
actuators.
FlowScannertConnections: Optional quick
disconnect connections are available for use with the
portable FlowScanner microprocessor-based
diagnostic testing unit.
Pipe-Away Vent: Some applications use natural gas or
other hazardous gases as a supply pressure to the
actuator. These applications require the actuator
housingtobevented,reducingtheaccumulationof
gases. For new constructions and retrofit kit
information, contact your Emerson Process
Management sales office with complete service
conditions.
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
4
Table 3. Mounting Styles and Positions
MOUNTING ACTION(1)
VALVE SERIES OR DESIGN VALVE SERIES OR DESIGN
BALL/PLUG
ROTATION TO
CLOSE
V250 V150, V200 and
V300
CV500 and
V500
DISC/BALL
ROTATION TO
CLOSE
V250
8510B, 8532,
8560
and 9500
Right-Hand PDTC
PDTO
CCW
CCW
A
B
A
B
A
B
CW
CW
NA
NA
B
A
Left-Hand PDTC
PDTO
CCW
CCW
NA
NA
D
C
D
C
CW
CW
C
D
C
D
Left-Hand
(Optional)(2)
PDTC
PDTO
CW
CW
NA
NA
C
D
NA
NA
NA
NA
NA
NA
NA
NA
1. PDTC–Push-down-to-close, and PDTO–Push-down-to-open.
2. A left hand ball will be required for the 3- through 12-inch Series B and the 14- to 20-inch, with or without attenuator.
Figure 2. Mounting Styles and Positions (also see table 3)
Notes:
Position 1 is standard; positions 2 through 4 (shown in dotted lines) are alternates.
2. By Emerson Process Management definition:
DForward flow is into the face side of the disc , or ball sealing surface.
DReverse flow is into the hub side of the disc or ball.
1
43A6506-A
A1579-5
LEFT-HAND
MOUNTING
STYLE C
STYLE D
STYLE B
STYLE A
RIGHT-HAND
MOUNTING
STYLE A STYLE B
STYLED STYLEC
POSITION 1
POSITION 1
FLOW
POSITION 1
POSITION 1
FLOW
4
3
24
3
33
4
4
2
2
2
STYLES
RIGHT-HAND MOUNTING
LEFT-HAND MOUNTING
1
1
1
1
Installation
The actuator is normally positioned vertically in a
horizontal pipeline. However, four mounting styles
and four positions are possible for each style (see
figure 2).
When looking in the direction of flow in the pipeline,
an actuator is right-hand mounted when it is on the
right side of the pipeline, and an actuator is left-hand
mounted when it is mounted on the left side of the
pipeline.
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
5
Figure 3. Fisher 1078 Declutchable Manual Actuator
41B0314-A
By Emerson Process Management definition, forward
flow is into the face side of the disc or ball, and reverse
flow is into the hub side of the disc or ball.
Dimensions for the 1061 actuator are shown in figure
6. These dimensions should be used in conjunction
with the mounting positions shown in figure 2.
Actuator Locking Mechanism
The 1061 actuator (sizes 30 through 100) is available
with a locking mechanism which may be used to keep
the actuator in the locked position during
maintenance shutdowns (see figures 4 and 5). The
device is intended to preventaccidentaloperationof
the valve during shutdown and does not imply or
qualify a control valve as a safety shutdown device.
Adjustable Travel Stops
An adjustable down travel stop for the 1061 size 30,
40, 60, and 68 actuators is installed in a special
actuator housing. The assembly consists of locking
screws, locknut, special end rod bearing, and special
lever.
As used here, down or downward means in a direction
toward the valve shaft and away from the piston and
diaphragm. Up or upward means in a direction away
from the valve shaft and toward the piston and
diaphragm.
The locking screw can be positioned to limit downward
travel of the actuator lever to any rotation between 0
and 90 degrees. The travel stop is installed similar to
thelockingmechanismshowninfigure4,exceptthe
travel stop does not accommodate a padlock and the
travel stop can be completely unscrewed from the
housing.
An adjustable up travel stop for the 1061 sizes 40
through 100 actuators is installed in the top of a
special actuator cylinder. The top of the special
cylinder is tapped and faced (machined) for the travel
stop. The assembly consists of a screw, locknut, and
pressure seal. The screw can be positioned to limit
upward travel of the piston to any rotation between 30
and 90 degrees. Longer screws are available to further
limit travel.
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
6
Figure 4. Actuator Locking Mechanism for Size 30, 40, 60, and 68 Actuators
MODIFIED
ACTUATOR
HOUSING
PADLOCK
(CUSTOMER
SUPPLIED)
LOCKING
MECHANISM
ACTUATOR
LEVER
34B0458-A
A6808
Figure 5. Actuator Locking Mechanism for Size 80 and 100 Actuators
MOUNTING
PLATE
SAFETY
LOCKOUT
LOCKSCREW
MODIFIED
HOUSING
LEVER
PADLOCK
CAP SCREW (4)
PADLOCK
(CUSTOMER
SUPPLIED)
44B0457-A
A6809
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
7
Table 4. Dimensions
ACTUATOR
SIZE
C E F H PY
w/o Positioner w/3610JP Pos.
mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches
30 171 6.75 378 14.88 53.8 2.12 114 4.50 175 6.88 281 11.07 73.2 2.88
40 206 8.12 425 16.75 63.5 2.50 121 4.75 186 7.31 292 11.50 76.2 3.00
60 267 10.50 406 16.00 63.5 2.50 121 4.75 186 7.31 292 11.50 76.2 3.00
68 324 12.75 483 19.00 63.5 2.50 121 4.75 186 7.31 292 11.50 76.2 3.00
80 324 12.75 714 28.12 123 4.84 213 8.38 345 13.62 452 17.81 127 5.00
100 381 15.00 714 28.12 123 4.84 213 8.38 345 13.62 452 17.81 127 5.00
130 489 19.24 926 36.47 169 6.67 291 11.46 471 18.55 578 22.74 167 6.56
Table 5. Dimensions
VALVE SHAFT DIAMETER
STYLE F MOUNTING: V-LINE, 8532, 8560, AND
ECCENTRICDISCVALVES STYLE G MOUNTING: 9500 SERIES VALVES V
T U W T U W
mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches
12.7 1/2 117 4.62 --- --- 14.3 0.56 117 4.62 --- --- 11.1 0.44 137 5.38
15.9 5/8 117 4.62 --- --- 14.3 0.56 146 5.75 31.7 1.25 11.1 0.44 137(1) 5.38(1)
19.1 and 25.4 3/4 and 1 152 6.00 31.7 1.25 14.3 0.56 146 5.75 31.7 1.25 11.1 0.44 160 6.31
31.8 and 38.1 1-1/4 and
1-1/2 235 9.25 45.9 1.81 17.5 0.69 210 8.25 50.8 2.00 17.5 0.69 148 5.81
44.5 and 50.8 1-3/4 and 2 273 10.75 50.8 2.00 20.5 0.81 241 9.50 69.8 2.75 17.5 0.69 286(2) 11.25(2)
63.5 2-1/2 337 13.25 76.2 3.00 23.8 0.94 --- --- --- --- --- --- 235 9.25
76.2 3(3) 533 21.00 127 5.00 33.5 1.32 --- --- --- --- --- --- 322 12.68
88.9 3-1/2(3) 533 21.00 127 5.00 33.5 1.32 --- --- --- --- --- --- 322 12.68
1. Dimension shown is for eccentric disc,V150, V200, V300, CV500, 8532, and 8560 valves only; For 7600 and 9500 valves, dimension “V” is 160 mm (6.31 inches).
2. Dimension shown is for size 60 and 68 actuators only; for Size 80 and 100 actuators, the dimension “V” is 235 mm (9.25 inches).
3. Dimensions shown are for V260 valves only.
Figure 6. Dimensions (also see tables 4 and 5)
12.7 AND 15.9 mm
(1/2 AND 5/8 INCH) DIA. SHAFT
19.1 mm (3/4 INCH)
AND LARGER DIA. SHAFTS
ACTUATOR/VALVE MOUNTING DIMENSIONS
SIZE 30 ACTUATOR SIZE 40 AND LARGER ACTUATORS
1/4 -18
NPT
1/4 -18
NPT
1/4 -18
NPT
F
P
E
H
YV
C
WW
TT
U
14A7224-D
14A7219-C
B0786-6
1061 Actuator
D100095X012
Product Bulletin
61.2:1061
February 2013
8
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they arenot
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
E1987, 2013 Fisher Controls International LLC. All rights reserved.
Fisher, Vee-Ball, FIELDVUE, TopWorx, GO, and FlowScanner are marks owned by one of the companies in the Emerson Process Management business unit of
Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other
marks are the property of their respective owners.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.