Emerson Fisher 1061 Data Sheet
2015-03-30
: Emerson Emerson-Fisher-1061-Data-Sheet-681931 emerson-fisher-1061-data-sheet-681931 emerson pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
Product Bulletin 1061 Actuator 61.2:1061 February 2013 D100095X012 Fisherr 1061 Pneumatic Piston Rotary Actuator Fisher 1061 pneumatic piston rotary actuators are used to operate splined-shaft rotary control valves such as Vee-Ballt valves, eccentric disc valves, and butterfly valves. The actuator/valve body linkage of this actuator can be positioned for either push-down-to-open or push-down-to-close action. Additionally, the 1061 actuator can be used with a two-position control signal for on-off service or with a valve positioner for throttling service. An optional handwheel actuator is also available to allow for auxiliary or emergency manual valve operation when the 1061 piston actuator is not in use. For complete information on the valve positioner and the manual handwheel actuator, refer to the appropriate bulletin. W8380-2 Features Application Flexibility–Actuator is available in push-down-to-open or push-down-to-close construction and may be mounted in any of four actuator/valve body mounting positions (see figure 2). Minimal Dead Band–Single-point linkage with splined and clamped lever minimizes lost motion and improves control accuracy. Compact Construction–Compared to similar actuators, overall size is reduced by as much as 30 percent. www.Fisher.com 1061 Actuator with FIELDVUE™ DVC6200 Digital Valve Controller Mounted on a Fisher V500 Valve Long Service Life–Rugged construction provides stability, corrosion resistance, and protection from deformation should the actuator be over-pressured. Accessibility–Actuator/valve body linkage is completely enclosed, yet the valve packing adjustment remains accessible without removing any parts. Monitoring Ease–Highly visible travel indicator allows easy determination of valve position. Product Bulletin 1061 Actuator 61.2:1061 February 2013 D100095X012 Specifications Available Configuration Actuator Sizes: J 30, J 40, J 60, J 68, J 80, J 100, and J 130 Action: Double-acting pneumatic piston rotary actuator for J throttling service when used with positioner, or J on-off service when used with switching devices Cylinder Operating Pressure Minimum Recommended: J 1.4 bar (20 psig) without positioner, or J 0.35 bar (5 psi) above actuator requirement with positioner(1). Maximum Allowable(2) Sizes 30 and 60: 6.9 bar (100 psig) Size 40: 10.3 bar (150 psig) Size 68: 5.9 bar (85 psig) Size 80: 10.3 bar (150 psig) Size 100: 10.3 bar (150 psig) Size 130: 10.3 bar (150 psig) Valve Shaft Diameters, mm (Inch) Size 30: J 12.7 (1/2), J 15.9 (5/8),J 19.1 (3/4), J 22.2 (7/8), J 25.4 (1), and J 31.8 (1-1/4) Sizes 40, 60, and 68: J 19.1 (3/4), J 22.2 (7/8), J 25.4 (1), J 31.8 (1-1/4), J 38.1 (1-1/2), J 44.5 (1-3/4), and J 50.8 (2) Sizes 80 and 100: J 44.5 (1-3/4), J 50.8 (2), and J 63.5 (2-1/2) Size 130: J 76.2 (3) and J 88.9 (3-1/2) Maximum Valve Shaft Rotation J 90 degrees without travel stop or J 60 degrees with optional travel stop Maximum Breakout Torque(1) Size 30: Up to 282 NSm (2500 lbfSin) Size 40: Up to 847 NSm (7500 lbfSin) Size 60: Up to 1130 NSm (10,000 lbfSin) Size 68: Up to 1540 NSm (13,600 lbfSin) Size 80: Up to 5080 NSm (45,000 lbfSin) Size 100: Up to 6290 NSm (55,700 lbfSin) with 63.5 mm (2-1/2 in.) valve shaft diameter Size 130: Up to 19,800 NSm (175,000 lbfSin) Stroking Time Dependent on actuator size, rotation, and positioner if used. If stroking time is critical, consult your Emerson Process Management sales office. Construction Materials Cylinder and Cylinder Flange: Aluminum Housing Cover: J Cast iron or J aluminum (only for size 130) Piston: J Aluminum or J Nylon-coated piston (optional only for sizes 30 to 100) Piston Rod: Chrome-plated stainless steel Lever: Ductile iron Sliding Seal: Aluminum O-Rings: Nitrile Housing: Sizes 30, 40, 60, and 68: Cast iron Sizes 80, 100 and 130: Aluminum Mounting Yoke: Cast iron Mounting Yoke Bushing: PTFE and steel Material Temperature Capabilities with Standard Elastomers(2) -34 to 82_C (-30 to 180_F) Pressure Connections 1/4 NPT internal, and for optional pipe-away vent, 3/4 NPT internal connection Size 130 uses 1 NPT internal connection. See table 1 Travel Indication Graduated scale and pointer located on actuator end of valve shaft Mounting Positions See figure 2 Approximate Weight See table 2 1. Actual actuator torque available depends on specific construction and casing pressure. For information on torque requirements of the valve being considered, contact your Emerson Process Management sales office. 2. The pressure/temperature limits in this manual and any applicable standard or code limitation for actuator should not be exceeded. 2 Product Bulletin 1061 Actuator 61.2:1061 February 2013 D100095X012 Figure 1. Sectional of Fisher 1061 Actuator W2288-3 W3827-1 Table 1. Displacement for 90 Degree Rotation PISTON DOWN SIZE 30 40 60 68 80 100 130 PISTON UP cm3 Inch3 cm3 Inch3 1100 2130 4060 7210 13,000 19,100 41,100 67 130 248 440 794 1165 2508 1200 2230 4380 7110 12,900 18,800 40,200 74 136 267 434 788 1150 2454 Table 2. Approximate Weight ACTUATOR SIZE kg Lb 30 40 60 68 80 100 130 22 29 39 56 122 135 299 49 63 86 123 246 298 660 Options Pneumatic Instruments: J 3710, J 3610JP, or J 3620JP pneumatic or electro-pneumatic positioners or J FIELDVUE DVC6200 Digital Valve Controllers are available. Also, the 377 Series trip valves are available with J lock-in-last position, J fail-up, or J fail-down action (for specifications, see separate bulletins). Potentiometer: It is used for remote valve rotation indication. Limit Switches: J TopWorx™ DXP M21GNEB limit switch for one through six single-pole, double-throw contacts (see separate bulletin), J GOt proximity switches for one or two single-pole, double-throw contacts, or J Micro-Switches or NAMCO switches for one or two single-pole, double-throw or double-pole, double-throw contacts. GO proximity switch are not available for size 80, 100 or 130 actuators. Handwheel Actuator: The Fisher 1078 manual declutchable actuator (see figure 3) allows auxiliary or emergency valve operation of sizes 30 through 100 when engaged (see bulletin 61.8:1078). Cylinder Bypass: The bypass valve is required when a handwheel actuator is specified. Locking Mechanism: The locking mechanism shown in figure 4 is available for sizes J 30, J 40, J 60, and J 68 actuators. The locking mechanism shown in figure 5 is available for sizes J 80 and J 100 actuators. FlowScannert Connections: Optional quick disconnect connections are available for use with the portable FlowScanner microprocessor-based diagnostic testing unit. Pipe-Away Vent: Some applications use natural gas or other hazardous gases as a supply pressure to the actuator. These applications require the actuator housing to be vented, reducing the accumulation of gases. For new constructions and retrofit kit information, contact your Emerson Process Management sales office with complete service conditions. 3 Product Bulletin 1061 Actuator 61.2:1061 February 2013 D100095X012 Table 3. Mounting Styles and Positions VALVE SERIES OR DESIGN MOUNTING ACTION(1) Right-Hand PDTC PDTO BALL/PLUG ROTATION TO CLOSE CCW CCW Left-Hand PDTC PDTO Left-Hand (Optional)(2) PDTC PDTO VALVE SERIES OR DESIGN V250 V150, V200 and V300 CV500 and V500 A B A B A B DISC/BALL ROTATION TO CLOSE CW CW NA NA 8510B, 8532, 8560 and 9500 B A CCW CCW NA NA D C D C CW CW C D C D CW CW NA NA C D NA NA NA NA NA NA NA NA V250 1. PDTC–Push-down-to-close, and PDTO–Push-down-to-open. 2. A left hand ball will be required for the 3- through 12-inch Series B and the 14- to 20-inch, with or without attenuator. Figure 2. Mounting Styles and Positions (also see table 3) STYLE B STYLE A 1 STYLE D LEFT-HAND MOUNTING STYLE C POSITION 1 POSITION 1 1 4 2 FLOW 2 4 3 STYLE B 3 RIGHT-HAND MOUNTING STYLE A STYLE D STYLE C 1 POSITION 1 POSITION 1 1 RIGHT-HAND MOUNTING STYLES FLOW 2 4 2 4 3 43A6506-A A1579-5 3 LEFT-HAND MOUNTING Notes: Position 1 is standard; positions 2 through 4 (shown in dotted lines) are alternates. 1 2. By Emerson Process Management definition: D Forward flow is into the face side of the disc , or ball sealing surface. D Reverse flow is into the hub side of the disc or ball. Installation The actuator is normally positioned vertically in a horizontal pipeline. However, four mounting styles and four positions are possible for each style (see figure 2). 4 When looking in the direction of flow in the pipeline, an actuator is right-hand mounted when it is on the right side of the pipeline, and an actuator is left-hand mounted when it is mounted on the left side of the pipeline. 1061 Actuator Product Bulletin 61.2:1061 February 2013 D100095X012 Figure 3. Fisher 1078 Declutchable Manual Actuator Actuator Locking Mechanism The 1061 actuator (sizes 30 through 100) is available with a locking mechanism which may be used to keep the actuator in the locked position during maintenance shutdowns (see figures 4 and 5). The device is intended to prevent accidental operation of the valve during shutdown and does not imply or qualify a control valve as a safety shutdown device. Adjustable Travel Stops An adjustable down travel stop for the 1061 size 30, 40, 60, and 68 actuators is installed in a special actuator housing. The assembly consists of locking screws, locknut, special end rod bearing, and special lever. As used here, down or downward means in a direction toward the valve shaft and away from the piston and diaphragm. Up or upward means in a direction away from the valve shaft and toward the piston and diaphragm. 41B0314-A By Emerson Process Management definition, forward flow is into the face side of the disc or ball, and reverse flow is into the hub side of the disc or ball. Dimensions for the 1061 actuator are shown in figure 6. These dimensions should be used in conjunction with the mounting positions shown in figure 2. The locking screw can be positioned to limit downward travel of the actuator lever to any rotation between 0 and 90 degrees. The travel stop is installed similar to the locking mechanism shown in figure 4, except the travel stop does not accommodate a padlock and the travel stop can be completely unscrewed from the housing. An adjustable up travel stop for the 1061 sizes 40 through 100 actuators is installed in the top of a special actuator cylinder. The top of the special cylinder is tapped and faced (machined) for the travel stop. The assembly consists of a screw, locknut, and pressure seal. The screw can be positioned to limit upward travel of the piston to any rotation between 30 and 90 degrees. Longer screws are available to further limit travel. 5 Product Bulletin 1061 Actuator 61.2:1061 February 2013 D100095X012 Figure 4. Actuator Locking Mechanism for Size 30, 40, 60, and 68 Actuators ACTUATOR LEVER MODIFIED ACTUATOR HOUSING PADLOCK (CUSTOMER SUPPLIED) LOCKING MECHANISM 34B0458-A A6808 Figure 5. Actuator Locking Mechanism for Size 80 and 100 Actuators PADLOCK MOUNTING PLATE CAP SCREW (4) SAFETY LOCKOUT LOCKSCREW PADLOCK (CUSTOMER SUPPLIED) 44B0457-A A6809 6 LEVER MODIFIED HOUSING Product Bulletin 1061 Actuator 61.2:1061 February 2013 D100095X012 Table 4. Dimensions ACTUATOR SIZE C E F P H w/o Positioner Y w/3610JP Pos. mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches 30 171 6.75 378 14.88 53.8 2.12 114 4.50 175 6.88 281 11.07 73.2 2.88 40 206 8.12 425 16.75 63.5 2.50 121 4.75 186 7.31 292 11.50 76.2 3.00 60 267 10.50 406 16.00 63.5 2.50 121 4.75 186 7.31 292 11.50 76.2 3.00 68 324 12.75 483 19.00 63.5 2.50 121 4.75 186 7.31 292 11.50 76.2 3.00 80 324 12.75 714 28.12 123 4.84 213 8.38 345 13.62 452 17.81 127 5.00 100 381 15.00 714 28.12 123 4.84 213 8.38 345 13.62 452 17.81 127 5.00 130 489 19.24 926 36.47 169 6.67 291 11.46 471 18.55 578 22.74 167 6.56 Table 5. Dimensions VALVE SHAFT DIAMETER STYLE F MOUNTING: V-LINE, 8532, 8560, AND ECCENTRIC DISC VALVES T U W STYLE G MOUNTING: 9500 SERIES VALVES T U V W mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches 12.7 1/2 117 4.62 - - - - - - 14.3 0.56 117 4.62 - - - - - - 11.1 0.44 137 5.38 15.9 5/8 117 4.62 - - - - - - 14.3 0.56 146 5.75 31.7 1.25 11.1 0.44 19.1 and 25.4 3/4 and 1 152 6.00 31.7 1.25 14.3 0.56 146 5.75 31.7 1.25 11.1 0.44 160 6.31 31.8 and 38.1 1-1/4 and 1-1/2 235 9.25 45.9 1.81 17.5 0.69 210 8.25 50.8 2.00 17.5 0.69 148 5.81 273 10.75 50.8 2.00 20.5 0.81 241 9.50 69.8 2.75 17.5 0.69 44.5 and 50.8 1-3/4 and 2 137(1) 5.38(1) 286(2) 11.25(2) 63.5 2-1/2 337 13.25 76.2 3.00 23.8 0.94 --- --- --- --- --- --- 235 9.25 76.2 3(3) 533 21.00 127 5.00 33.5 1.32 --- --- --- --- --- --- 322 12.68 88.9 3-1/2(3) 533 21.00 127 5.00 33.5 1.32 --- --- --- --- --- --- 322 12.68 1. Dimension shown is for eccentric disc, V150, V200, V300, CV500, 8532, and 8560 valves only; For 7600 and 9500 valves, dimension “V” is 160 mm (6.31 inches). 2. Dimension shown is for size 60 and 68 actuators only; for Size 80 and 100 actuators, the dimension “V” is 235 mm (9.25 inches). 3. Dimensions shown are for V260 valves only. Figure 6. Dimensions (also see tables 4 and 5) C 1/4 -18 NPT U 1/4 -18 NPT E 1/4 -18 NPT W F P W 12.7 AND 15.9 mm (1/2 AND 5/8 INCH) DIA. SHAFT H 14A7224-D 14A7219-C B0786-6 T T SIZE 30 ACTUATOR Y V 19.1 mm (3/4 INCH) AND LARGER DIA. SHAFTS SIZE 40 AND LARGER ACTUATORS ACTUATOR/VALVE MOUNTING DIMENSIONS 7 Product Bulletin 61.2:1061 February 2013 1061 Actuator D100095X012 Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user. Fisher, Vee-Ball, FIELDVUE, TopWorx, GO, and FlowScanner are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. Emerson Process Management Marshalltown, Iowa 50158 USA Sorocaba, 18087 Brazil Chatham, Kent ME4 4QZ UK Dubai, United Arab Emirates Singapore 128461 Singapore www.Fisher.com E 8 1987, 2013 Fisher Controls International LLC. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Create Date : 2013:01:31 09:53:34-06:00 Modify Date : 2013:01:31 09:54:12-06:00 Metadata Date : 2013:01:31 09:54:12-06:00 Producer : Acrobat Distiller 9.5.1 (Windows) Format : application/pdf Title : untitled Document ID : uuid:9c0cf4a3-8c81-436a-9123-e6774e779e9d Instance ID : uuid:74cd57c3-3dc0-4762-a069-3d83cc393f4a Page Count : 8EXIF Metadata provided by EXIF.tools