Field Communicator Menu Tree
FIELDVUE™ DLC3020f Digital Level Controller

Overview
Overview
 Check Status
 Primary Purpose Variables
 Shortcuts

www.Fisher.com
For the telephone number of the Emerson Process
Management sales office nearest you, contact:
In North America
Fisher Controls International LLC
1 (641) 754‐3011
In Latin America
Fisher Controls International LLC
1 (314) 746‐9900

Check Status
 Device Status:
   Good
   Failed
   Maintenance or
   Advisory
 Mode Status:
   In Service or
   Not in Service
Shortcuts
 Device Information
 Calibration/Setup Logs

DLC3020f Digital Level Controller

In Asia Pacific
Emerson Process Management
Asia Pacific Private Ltd.
(65) 6777‐8211
In Europe
Emerson Process Management Ltd.
+44 1634 895800

475 Field
Communicator

For equipment service or support needs, contact
your local Emerson Process Management sales office

www.Fisher.com
D103602X012 May 2012
FIELDVUE and Fisher are marks owned by one of the companies in the Emerson Process
Management business unit of Emerson Electric Co. Emerson, Emerson Process
Management, and the Emerson logo are trademarks and service marks of Emerson
Electric Co.
© 2012 Fisher Controls International LLC. All rights reserved.

Home
 Overview
 Configure
 Service Tools
  (on back side)
 Advanced

Manual Setup
Configure
 Instrument Setup
 Manual Setup
 Alert Setup
  (on back side)
 Calibrate
  (on back side)

Temperature Compensation
 Temperature Input
 Temperature For Compensation
  (Visible if Temperature
 Input = None only)

Calibration/Setup Log
  Methods
 View
 Restore
 Save Current
 Rename
 Delete

Upper Fluid
 Fluid Name
 Density in Use
Lower Fluid
 Fluid Name
 Density in Use

Density Tables
 Upper Fluid Density Table
 Lower Fluid Density Table 

DLC3020f Digital Level Controller
Device Information
 Device Overview
 Version Information
 Manufacturing Information
Manufacturing Information
 Lever Assembly ID
 Communication Module ID
 Sensor Module ID
 Shop Order Number
 Terminal Box Date Code
Calibration/Setup Logs
 Calibration in Use
 Calibration/Setup Log Methods

Manual Setup
 Mode
 Device
 Process Fluid (Level only)
 Process Fluids (Interface only)
 Instrument Display
 Snap Acting Control
 Options
 (continued on back side)
Process Fluids (Interface only)
 Upper Fluid
 Lower Fluid
 Change Process Fluid
 Temperature Compensation
Density Tables
Upper Fluid Density Table
Lower Fluid Density Table
 Temperature 1
 Density 1
 Temperature 2
 Density 2
 ...
 ...
 Temperature 10
 Density 10

Device Overview
 Instrument Model Number
 Instrument Serial Number
Version Information
 Device Revision
 Firmware Revision
 Hardware Revision
 Major Sensor Revision
 Minor Sensor Revision
 DD Information
Calibration In Use
 Name
 Date
 Calibration Method
 Calibrator

Device
 Variable Configuration
 Sensor Units
 Sensor Parameters
 Torque Tube
 Sensor Hardware Information
Process Fluid (Level only)
 Process Fluid
 Change Process Fluid
 Temperature Compensation
 Density Table
Density Table
 Temperature 1
 Density 1
 Temperature 2
 Density 2
 ...
 ...
 ...
 ...
 Temperature 10
 Density 10

Menu Tree applies to
Device Revision

Hardware Revision

Firmware Revision

DD Revision

1

1.0

1.0

0x03

Italics text = Method
Variable Configuration
 Type of Measurement
 Primary Value Range High
 Primary Value Range Low
 Primary Value Offset
 Primary Value Range Units

Sensor Parameters
 Displacer Length
 Displacer Volume
 Displacer Weight
 Driver Rod Length
 Instrument Mount Position
Torque Tube
 Torque Tube Material
 Compensated Torque Rate
 Torque Tube Table
Sensor Hardware Information
 Model Type
 End Connection Style
 End Connection Type
 Body Material
 Pressure Rating
 Mechanical Sensor Serial Number
 Displacer Size
 Displacer Material
 Displacer Rating
 G Dimension
 Torque Tube Material
 Torque Tube Wall
 Heat Insulator 
Temperature Compensation
 Temperature Input
 Temperature For Compensation
  (Visible if Temperature
  Input = None only)

Sensor Units
 Unit System
 Length Units
 Volume Units
 Weight Units
 Temperature Units
 Torque Rate Units
 Fluid Density Units
Torque Tube Table
 Temperature 1
 Gain 1
 Temperature 2
 Gain 2
 ...
 ...
 ...
 ...
 Temperature 10
 Gain 10

Process Fluid
 Fluid Name
 Density in Use

Manual Setup
(continued)
Configure
 Instrument Setup
 Manual Setup
 Alert Setup
 Calibrate

Manual Setup (continued)
 Mode
 Device
 Process Fluid (Level)
 Process Fluids (Interface)
 Instrument Display
 Snap Acting Control
 Options

Options
 Resource Block Tag
 Transducer Block Tag
 Write Lock
 Confirm Time
 Communication Timeout
 Function Block Available
 Features Selected
 Write Alarm
 Block Alarm
 Alert Key

Block Alarm
 Block Alarm Disabled
 Block Alarm Alarm State
 Block Alarm Unacknowledged
Write Alarm
 Disc Alarm Disabled
 Write Alarm Alarm State
 Write Alarm Unacknowledged

Resource Block Tag
 Tag Description
 Strategy
Transducer Block Tag
 Tag Description
 Strategy

Instrument Display
 Display Option
 Device Display Primary Value Units
 Decimal Places
 Display Primary Value Offset
 Scroll Message Control

Scroll Message Control
 Primary Value Bad
 Primary Value Uncertain
 Failed Alert
 Maintenance Alert
 Advisory Alert

Snap Acting Control
 Primary Value
 Primary Value Percent
 Snap Acting Control
 Snap Units
 DI1 Trip Point Settings
 DI2 Trip Point Settings

DI1 Trip Point Settings
 DI1 Action
 DI1 Trip Point
 DI1 Deadband
 DI1 Readback
DI2 Trip Point Settings
 DI2 Action
 DI2 Trip Point
 DI2 Deadband
 DI2 Readback

Write Lock
 Write Lock
 Write Priority
Communication Timeout
 Shed Remote Cascade
 Shed Remote Out
Function Block Available
 CasIn to Transducer Block
Features Selected
 Reports
 Fault State
 Write Lock
 Reannunciation

Alert Setup
Configure
 Instrument Setup
 Manual Setup
 Alert Setup
 Calibrate

Alert Setup
 Rapid Rate Limit (length/sec)
 Clear Rate Limit Alert
 PlantWeb Alert Enable
 PlantWeb Alert Reporting

PlantWeb Alert Reporting
 Failed Suppress
 Maintenance Suppress
 Advisory Suppress

Calibrate
Configure
 Instrument Setup
 Manual Setup
 Alert Setup
 Calibrate

Calibrate
 Calibration in Use
 Full Calibration (Bench)
 Full Calibration (Field)
 Expert User Calibration

Bench Calibration
 Weight
 Min/Max
 Two Point

Expert User Calibration
 Bench Calibration
 Field Calibration
 Trim Current Calibration

Field Calibration
 Simple Zero/Span
 Min/Max
 Two Point
 Two Point Time Delay
Trim Current Calibration
 Zero Trim
 Gain Trim
 Default Gain

Service Tools
Home
 Overview
 Configure
 Service Tools
 Advanced

Service Tools
 Mode
 Alerts
 Variables
 Maintenance
 Simulate

Maintenance
 Calibration/Setup Logs
 Restart Options
 LCD Test
Simulate
 Simulate Alert Conditions
 Simulate Active Alerts

PlantWeb Alert Enable
 Failed Enable
 Maintenance Enable
 Advisory Enable

Calibration in Use
 Name
 Date
 Calibration Method
 Calibrator

Simulate Active Alerts
 Failed Active
 Maintenance Active
 Advisory Active

Primary Value
 Primary Value
 Primary Value Percent

Variables
 Type of Measurement
 Primary Value
 Upper Fluid (Interface only)
 Lower Fluid (interface only)
 Process Fluid (Level only)
 Compensated Torque Rate
 Temperature Compensation
 Run Time Extremes

Upper Fluid (Interface only)
 Fluid Name
 Density in Use

Calibration/Setup Logs
 Calibration In Use
 Calibration/Setup Log Methods

Process Fluid (Level only)
 Fluid Name
 Density in Use

Calibration/Setup Log
Methods
 View
 Restore
 Save Current
 Rename
 Delete
LCD Test
 Enable/Disable LCD Test
 Device Display Test
 Display Primary Value
 Display Primary Value Percent

Lower Fluid (Interface only)
 Fluid Name
 Density in Use

Calibration In Use
 Name
 Date
 Calibration Method
 Calibrator

Run Time Extremes
 Run Time
 Time Since Reset
 Instrument Temperature
 Maximum Recorded Temperature
 Minimum Recorded Temperature
 Time Over Upper Temperature Limit
 Time Under Lower Temperature Limit
 Temperature Integral (deg-days)



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39
Producer                        : Acrobat Distiller 8.3.1 (Windows)
Modify Date                     : 2012:04:09 15:55:21-05:00
Create Date                     : 2012:04:09 15:54:29-05:00
Metadata Date                   : 2012:04:09 15:55:21-05:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:f06fdfd3-dd8e-4fa2-830e-e983d6f1bd52
Instance ID                     : uuid:b1b7b51d-e625-4c2a-a31c-aaa5f84cbdf9
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu