Product Bulletin

ValveLink Software

62.1:ValveLink Software(S2)
October 2012

D102687X102

ValveLinkt Software Signature Series
Performance Testing
ValveLink Software Signature Series factory-executed
performance testing is available for any Fisherr control
valve assembly that includes a FIELDVUEt digital valve
controller.
Signature Series performance testing creates a
benchmark of an assembled valve's performance just
prior to shipment. This benchmark provides a starting
point for future data comparison, enabling you to
track the operating condition of your control valve and
maximize valve performance.
When ordered with your FIELDVUE equipped control
valve, our factory uses the diagnostic capability of
ValveLink software to thoroughly test each valve
assembly.

Test Levels
Three levels of Signature Series tests are available, with
each level providing valuable diagnostic data. When
you order a Signature Series test, you will receive the
test results electronically from your Emerson Process
Management sales office.

Signature Series 1
Within the Signature Series 1 test level, you receive:
n Instrument Configuration

W9363-3

Signature Series 2
In addition to Signature Series 1 information, you
receive:
n Performance Step Test
n Status Monitor (0, 25, 50, 75, 100% travel)

Signature Series 3
Series 3 testing provides user specified Series 1 and 2
tests and allows customization of end points or scan
times. This capability lets you tailor the testing to your
specific requirements or process needs.

n Status Monitor (@50% travel)
n Valve Spec Sheet
n Valve Signature, as recorded from -5 to 105% input.
n Dynamic Error Band Curve, as recorded from

-5 to 105% input
n Drive Signal, as recorded from -5 to 105% input

www.Fisher.com

Signature Series 3 with Dead Band
plus Hysteresis
Provides user specifications from Series 1, 2, 3, and
Dead Band plus Hysteresis estimation per dead band
specifications. Refer to Bulletin 62.1:ValveLink
Software(S3) (D103549X012), available from your
Emerson Process Management sales office, for details.

Product Bulletin

ValveLink Software

62.1:ValveLink Software(S2)
October 2012

D102687X102

Data Comparison
If your control valve is equipped with a FIELDVUE
instrument that includes diagnostic capability, after
the valve has been in service you can use ValveLink
Software to run the same tests that were originally run
at the factory. Then, by importing the Signature Series
data into ValveLink Software, you can compare the
as‐shipped performance with the valve's current
operating condition. The current data can be
compared to the baseline data to quickly pinpoint
issues, as shown in figure 1.

Take Advantage of the
Signature Series
You can begin to take advantage of the Signature
Series by contacting your Emerson Process
Management sales office. Remember to specify your
Signature Series testing requirements when placing
your order. Emerson Process Management can provide
you with the diagnostic data you need to keep your
valves operating at top performance!
Figure 2. Performing a Diagnostic Test with
ValveLink Software Provides an Analysis of Control
Valve Operating Parameters

Figure 1. Data Comparison

ORIGINAL
TEST

NEW
TEST

INCREASED SPAN INDICATES
INCREASED FRICTION

Signature Series Availability
Signature Series testing is available for all Fisher
control valves when specified as part of the original
valve order. To order Signature Series testing, simply
specify your Signature Series testing requirements on
your Fisher control valve orders. Signature Series tests
are only available when specified as part of the original
valve order.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher, ValveLink, and FIELDVUE are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co.
Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property
of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore

www.Fisher.com
E
2 1999, 2012 Fisher Controls International LLC. All rights reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 2
XMP Toolkit                     : XMP toolkit 3.0-28, framework 1.6
About                           : uuid:23eb4ae6-7891-4927-8651-6f030d8d0c84
Producer                        : Acrobat Distiller 8.3.1 (Windows)
Modify Date                     : 2012:10:01 07:56:03-05:00
Create Date                     : 2012:09:25 10:20:01-05:00
Metadata Date                   : 2012:10:01 07:56:03-05:00
Document ID                     : uuid:58fe7411-ec42-41b2-946e-95a8e60e4d55
Instance ID                     : uuid:23eb4ae6-7891-4927-8651-6f030d8d0c84
Format                          : application/pdf
Title                           : untitled
EXIF Metadata provided by EXIF.tools

Navigation menu