Liebert® PSA™ Quick-Start Guide - 500VA/650VA, 120V IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS • Connect the UPS only to an earthed / grounded outlet that meets national and local electrical safety guidelines. • Locate the UPS near a wall outlet. Do not use an extension cord between the UPS and the outlet. • The Liebert PSA has been designed for small office/home office use only; it is NOT recommended for use in life-support applications. • In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS. • Do not attach power strips or surge suppressors to the UPS. • Do not attempt to service any parts inside the UPS except the batteries. Failure to adhere to this could cause personal injury or equipment malfunction and void the warranty. • For technical support: • Visit www.liebert.com or • Send an e-mail to upstech@emersonnetworkpower.com. This manual contains important instructions that should be followed during installation and maintenance of the UPS. • Intended for installation in a controlled environment. • Maximum ambient temperature 104°F (40°C). ! CAUTION To reduce the risk of fire, connect only to a circuit provided with 20 amperes maximum branch circuit overcurrent protection in accordance with the national code, ANSI/NFPA 70. • Do not connect equipment that may overload the UPS or demand half-wave rectification, such as a laser printer. SETUP Step 1 Inspect the Package Step 5 Check the Site Wiring Fault Indicator Inspect the package and the UPS upon receipt. Notify the carrier and dealer of visible damage. See figure at right for the location of the Site Wiring Indicator on the rear of the UPS. • Check the rear of the UPS to make sure the Site Wiring Fault indicator is NOT illuminated. Caution: If the Site Wiring Fault indicator is illuminated, have a qualified electrician check the wall receptacle wiring and fix any problems. Liebert shutdown software CD Step 6 Connect the Loads The UPS has three battery backup outlets that provide power when the UPS operates on battery (see Figure 2 below). Quick-start guide USB cable • Plug the loads into the battery backup outlets on the rear of the UPS. UPS Step 2 Decide Where to Place the UPS Caution: Do not connect a laser printer to the UPS. The UPS must be placed indoors, protected from water, direct sunlight and excessive heat. Step 7 Connect the Network Surge Protection The UPS has two RJ-45 jacks for network lines (see Figure 2 below). Provide at least 4" (100mm) of clearance on all sides of the unit for proper ventilation. • Connect a single-line network cable into the RJ-45 network surge protection IN jack on the rear of the UPS. • Connect an RJ-45 cable from the OUT jack on the rear of the UPS to a port on a PC or network device such as a router. Step 3 Charge the UPS Battery Before Use The UPS battery is not charged before shipping. It MUST be charged before use. • Connect the UPS power cord to a wall outlet and charge for at least eight hours. Step 8 Set Up Liebert shutdown software Note: If battery is placed in storage, charge the battery every six months if kept at 5°F to 85°F (-15°C to 29°C)—or every three months if kept at 86°F (30°C) or higher. To start using the Liebert shutdown software: Step 4 Start the UPS After the battery is fully charged: • Turn on the UPS by pressing the On/Off button (see Figure 1 below). LED 1 should be illuminated (green), indicating the UPS is operating in Normal Mode. • Install the Liebert shutdown software. See the software user manual for installation instructions. • Connect one end of the USB cable (supplied) to the USB port on the rear of the UPS. Connect the other end to a USB port on the computer. See the software user manual for operating instructions. UPS CONTROLS AND CONNECTIONS Figure 1 - Front Panel LEDs Figure 2 - Rear Panel On/Off button LED 1 (green) LED 2 (red = fault; amber = overload) ! Utility symbol Overload symbol Network Power Liebert PSA ™ RJ-45 jacks (2) network protection Input breaker Fault symbol EMERSON Site Wiring Fault indicator USB interface ® NEMA 5-15P Battery backup outlets (3) NEMA 5-15R Surge outlet (1) NEMA 5-15R AC Power System UPS Status, Alarm Conditions and Alerts Condition LED Color Solid/Flashing Audible Alarm Normal Mode LED 1 Green Solid (steady glow) (None) Battery Mode LED 1 Green Flashes every 3 seconds Every 3 seconds Battery Low LED 1 Green Flashes every 1 second till end of discharge (EOD) Every 1 second Overload LED 2 Amber Solid (steady glow) until load drops or breaker trips Continuous Battery Replacement LED 2 Red Flashes every 1 second for 5 seconds only Every 1 second for 5 seconds only Fault LED 2 Red Solid (steady glow) until UPS shuts down after 5 seconds Continuous until UPS shuts down REPLACING THE BATTERY To replace the battery: 1. Turn off all connected loads, then turn off the UPS (batteries are NOT hot-swappable). 2. Use a Phillips head screwdriver to remove the two screws from the bottom edge of the front panel. 3. Slide the panel downward and remove it. 4. Gently pull the battery out of the UPS. 5. Remove the black wire from the negative (-) terminal and the red wire from the positive (+) terminal. 6. Verify that the replacement battery matches the dimensions and battery type in the Specifications section below. 7. Connect the battery leads to the new battery. Be sure to reconnect the red wire to the positive (+) terminal and the black wire to the negative (-) terminal. Steps 2 and 3 Steps 4 and 5 Note: Small sparks may occur at the battery connectors during reconnection. 8. Slide the battery into the UPS. 9. Close the front panel and replace the two screws from Step 2. Dispose of the old battery properly at an appropriate recycling facility. TROUBLESHOOTING If the UPS malfunctions during operation, check the following chart for proper adjustment. For further assistance, please contact your local Emerson Network Power representative. Problem Possible Causes Solutions The UPS may not be turned on. • Press the On/Off button to turn on the UPS. The power cord may not be connected properly. • Connect the power cord securely into a wall outlet. The upstream input circuit breaker may be tripped. • Reset the input circuit breaker. LED 1 flashes (green) every 3 seconds, but there is no output power. Battery voltage may be too low. • Recharge the UPS for 8 hours. Alarm buzzer beeps continuously although utility power is normal. The UPS may be overloaded (check LED 2). • Disconnect some equipment from the UPS. UPS does not provide expected backup time. The UPS battery reached end of life. • Replace the internal battery. The UPS is on and connected to input power, but fails to operate properly. Utility power may be outside the unit’s operating range. • If utility power is normal, try reconnecting input power and restarting the UPS. Utility power is normal, but LED 1 is not illuminated. SPECIFICATIONS Model Number PSA500MT3-120U PSA650MT3-120U 500/300 650/390 Net Weight, lb. (kg) 14.1 (6.4) 14.6 (6.6) Shipping Weight, lb. (kg) 15.9 (7.2) 16.3 (7.4) Capacity (VA/W) Dimensions - W x D x H, in. (mm) 3.7 x 14 x 6.7 (95 x 356 x 171) On-Line Input Voltage 84-140VAC On-Line Frequency 50/60Hz ±5Hz Output Voltage (Utility Power Normal) Typical 97-129VAC Output Voltage (Battery Operation) 120VAC ±5% On-Battery Wave Form Stepped sinewave Battery Type - VDC x Ah x Quantity 12V x 7Ah x 1 Typical Recharge Time 6-8 hours to 90% Battery Run Time* - Full Load 3-5 minutes Battery Run Time* - Half Load 10 minutes Audible and Visual Audible alarm / LED Backup Outlets NEMA 5-15R (3) Surge Outlets NEMA 5-15R (1) Operating Temperature, °F (°C) 32 to 104 (0 to 40) Storage Temperature, °F (°C) 5 to 104 (-15 to 40) Operating / Storage Relative Humidity 0%-90%, non-condensing EMI Classification FCC Part 15 Class B Agency Safety Transportation UL 1778, c-UL Listed ISTA Procedure 1A Certification * Battery run time may vary depending on load © 2008 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice. ® Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners. SL-23300_REV0_04-08 Technical Support / Service United States 800-222-5877 (Outside U.S. 614-841-6755) upstech@emersonnetworkpower.com Web site: www.liebert.com 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2003:07:16 21:05:42Z Creator Tool : FrameMaker 8.0 Modify Date : 2008:05:06 12:49:02-04:00 Metadata Date : 2008:05:06 12:49:02-04:00 Format : application/pdf Creator : . Title : Document ID : uuid:3c6d062f-5494-4dce-bbc4-ca8ceb85451d Instance ID : uuid:604c4d5b-ab19-4836-97b5-eb020449918f Page Count : 2EXIF Metadata provided by EXIF.tools