- Chapter 1. Introduction
- 1.1 Preface
- 1.2 Overview
- 1.3 Function Descriptions
- 1.3.1 Rectifier Control
- 1.3.2 Converter Control
- 1.3.3 System Components Monitoring and System Alarms Generation
- 1.3.4 Operating Data Acquisition and Data Logs
- 1.3.5 Battery Management
- General Battery Management
- Spec. No. 588820300 Battery Rack System (Lithium Ion Battery Configuration)
- Battery Charge Temperature Compensation
- Battery Equalize Charge and Battery Charge Current Limit
- High and Low Battery Temperature Alarms
- Battery Thermal Runaway Management (BTRM) Feature
- Battery Discharge Test and Battery Test Logs
- Battery LVD (Low Voltage Disconnect)
- Battery Capacity Prediction
- Battery Block and Battery Midpoint Monitoring
- Enhanced Battery Monitoring with SM-BRC
- Thermal Runaway Detection and Management
- 1.3.6 Intelligent Power Matching (Energy Optimization Mode)
- 1.3.7 Power Split Feature
- 1.3.8 Diesel Management Feature
- 1.3.9 PLC (Programmable Logic Controller) Function
- 1.3.10 Supervisory Module (SM Modules) Monitoring
- 1.3.11 Hybrid Control Function
- 1.3.12 Maximum Current Limit Function
- Chapter 2. Operation
- 2.1 Local Indicators
- 2.2 Passwords and Access Levels
- 2.3 Local Keypad and Display Access
- 2.4 WEB Interface Access
- 2.5 Common Tasks Performed via the Local Keypad and/or Web Interface
- 2.5.1 Backing Up the Configuration
- 2.5.2 Reloading a Backed-Up Configuration
- 2.5.3 Reloading the Configuration File Stored in the ACU+ Controller
- 2.5.4 Downloading a Configuration or an Application ("All") Package into the ACU+ Controller
- 2.5.5 Rebooting the Controller
- 2.5.6 Changing the Local LCD Display Contrast
- 2.5.7 Disabling the Local Keypad Sound
- 2.5.8 Changing the Date
- 2.5.9 Changing the Time
- 2.5.10 Adding, Deleting, and Modifying Users
- 2.5.11 Assigning Severity Level to Alarms
- 2.5.12 Assigning Relays to Alarms
- 2.5.13 Changing the Names of Items Displayed in the LCD and Web-Interface Menus
- 2.5.14 Viewing Alarms
- 2.5.15 Clearing Rectifier Lost, Rectifier Communication Fail, Converter Lost, Converter Communication Fail, and All Converter Comm Fail Alarms
- 2.5.16 Clearing SMTemp Lost and SMTemp Probe Alarms
- 2.5.17 Clearing Battery Alarms
- 2.5.18 Clearing Logs
- 2.5.19 Clearing the Maintenance Alarm
- 2.5.20 Viewing the ACU+ Controller’s Device Inventory
- 2.5.21 Updating the ACU+ Controller’s Device Inventory
- 2.5.22 Programming the Audible Alarm Feature
- 2.5.23 Blocking Alarms
- 2.5.24 Configuring the ACU+ Identification of Rectifiers and Assigning which Input Phase is Connected to the Rectifiers
- 2.5.25 Configuring the ACU+ Identification of Converters
- 2.5.26 Viewing/Changing the Float Voltage Setting
- 2.5.27 Viewing/Changing the Equalize Voltage Setting
- 2.5.28 Setting Digital Inputs
- 2.5.29 Setting Temperature Sensors
- 2.5.30 Setting Battery Charge Temperature Compensation
- 2.5.31 Setting Auto Equalize
- 2.5.32 Setting Battery Parameters
- 2.5.33 Setting Battery Capacity Parameters
- 2.5.34 Setting Battery Block and Battery Midpoint Monitoring (if equipped with an EIB Assembly)
- 2.5.35 Setting IP Communications Parameters
- 2.5.36 Setting External Shunts (connected to the EIB Assembly)
- 2.5.37 Setting External Shunts (connected to the SM-DU+ Assembly)
- 2.5.38 Setting the Load Current Alarm
- 2.5.39 Placing the System in Float or Equalize Charge Mode
- 2.5.40 Manually Forcing Relays
- 2.5.41 Manually Forcing LVDs
- 2.5.42 Using the Relay Test Feature
- 2.5.43 Spec. No. 588820300 Battery Rack System (Lithium Ion Battery Configuration)
- 2.6 Available Alarms
- 2.7 Power Split Feature
- Chapter 3. Local Display Menus
- Chapter 4. WEB Interface Menus
- 4.1 Overview
- 4.2 Homepage
- 4.3 Menu Navigation Window
- 4.4 Device Information Menu
- 4.5 Quick Settings Menu
- 4.6 Query Menu
- 4.7 Maintenance Menu
- 4.7.1 Network Configuration Sub-Menu
- 4.7.2 NMS (Network Management System) Configuration Sub-Menu
- 4.7.3 HLMS (High Level Management System) Configuration Sub-Menu
- 4.7.4 Edit PowerSplit Sub-Menu
- 4.7.5 User Information Settings Sub-Menu
- 4.7.6 Clear Data Sub-Menu
- 4.7.7 Restore Factory Defaults Sub-Menu
- 4.7.8 Download Sub-Menu
- 4.7.9 Retrieve ‘SettingParam.run’ File Sub-Menu
- 4.7.10 Time Sync Sub-Menu
- 4.7.11 System Inventory Sub-Menu
- 4.8 Configuration Menu
- Chapter 5. Accessing the Controller via a Network Management System (NMS)
- Chapter 6. Replacement Procedures
- Chapter 7. Specifications