Emotiv FLEX01 EEG Headset User Manual

Emotiv Inc EEG Headset

User manual

        EPOC Flex  User Manual   Last updated: June 12, 2018 Copyright EMOTIV, Inc.   EMOTIV EPOC Flex Manual 1 of 15
 Table of Contents EPOC Flex 1 User Manual 1 Table of Contents 2 Introduction 3 Safety Precautions 3 Technical Specifications 4 Compliance Accreditation 5 Controller Assembly› 6 Charging and LED Indicators 7 Electrode Assemblies 8 Example Electrode placement 8 EPOC Flex Cap 10 Specifying Cap Size 11 Package ContentsAssembly - Quick Start 13 Assembly Quick Start 15 Cleaning and Maintenance 16    EMOTIV EPOC Flex Manual 2 of 15
 Introduction This document is intended to help you get started using the EPOC Flex. The EPOC Flex is a                                   32-channel, flexible EEG system. It was built on the award winning EPOC+ technology and is                             designed for researchers who would like to have a more flexible sensor placement and / or                               greater density of sensors. The reference sensors can be placed in any location on the ear with                                 included earclips. EmotivPRO v1.4+ is required for operation.   If you have any queries beyond the scope of this document, please contact us through our                               online support.  Safety Precautions ● EPOC Flex is a consumer product, it is not intended to use be used for in-patient health                                 care or in hazardous environments. ● EPOC Flex is designed to be used at room temperature; rapid changes in temperature                           will affect the performance of the amplifiers and increase the noise floor. ● EPOC Flex can be used with gel or saline based sensors. ● WARNING: EPOC+ is powered by a Lithium-Polymer battery that is rated for operation                         in <45C environments. It is not user replaceable, please contact support if you suspect a                             fault or have any questions.  ● WARNING: Do not open the enclosure. Doing so will void the warranty and can damage                             the headset. ● WARNING: Do not charge EPOC Flex while wearing the device. In the unlikely event                           your PC has a faulty power supply you and your headset could unintentionally become                           the ground path and so If EPOC Flex detects a USB connection when turned on it will                                 stop communicating.       EMOTIV EPOC Flex Manual 3 of 15
 Technical Specifications No. of Channels 32 (plus CMS/DRL references) Channel names (International 10-20 locations) Configurable on standard 72 channel 10-20 map. Sampling method Sequential sampling. Single ADC Sampling rate 128 SPS (1024 Hz internal) EEG Resolution 14 bits 1 LSB = 0.51μV (16 bit ADC, 2 bits instrumental                       noise floor discarded) Max Slew Rate 32.64uV/sample (Compression required for BLE data           transmission) Bandwidth 0.2 - 45Hz, digital notch filters at 50Hz and 60Hz Filtering Built in digital 5th order Sinc filter Dynamic range (input referred) +/- 4.12 uV Coupling mode AC coupled Connectivity Proprietary 2.4GHz wireless, BLE(coming soon) Battery Capacity. LiPo battery 680mAh Battery life (typical) 9 hours Impedance Measurement Real-time contact quality using patented system IMU Part ICM-20948 (support coming soon) Accelerometer 3-axis +/-8g Gyroscope 3-axis +/- 2000 dps Magnetometer 3-axis +/- 12 gauss MEMS Sampling 16 Hz MEMS Resolution 16-bit  Sensor Material Sintered Ag/AgCl can be used with gel     EMOTIV EPOC Flex Manual 4 of 15
 Compliance Accreditation  FCC ID Number 2ADIH-FLEX01 and IC ID Number: 12769A-FLEX01.  EMOTIV has undertaken testing and confirms:  This device complies with the radio equipment directive (2014/53/EU).  This device complies with part 15 of the FCC Rules. Operation is subject to the following two                                 conditions: (1) This device may not cause harmful interference, and (2) this device must accept                             any interference received, including interference that may cause undesired operation.   This equipment has been tested and found to comply with the limits for a Class B digital device,                                   pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable                             protection against harmful interference in a residential installation. This equipment generates,                     uses and can radiate radio frequency energy and, if not installed and used in accordance with                               the instructions, may cause harmful interference to radio communications. However, there is no                         guarantee that interference will not occur in a particular installation. If this equipment does                           cause harmful interference to radio or television reception, which can be determined by turning                           the equipment off and on, the user is encouraged to try to correct the interference by one or                                   more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is                                   connected. - Consult the dealer or experienced person for help.  This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.  This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,                 Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to                     the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause                     undesired operation of the device.  Please Note: Changes or modifications not expressly approved by the party responsible                       for compliance could void the user's authority to operate the equipment. EMOTIV EPOC Flex Manual 5 of 15
     EMOTIV EPOC Flex Manual 6 of 15
 Controller Assembly›  The EPOC Flex controller pictured above has 16 channels connected on the left + CMS input                               and 16 channels on the right + DRL output. These channels are connected in two rows A-H and                                   J-Q, In software L or R is added in front to make it LA, LB, etc and RA, RB, etc. These labels                                           allow users to easily trace signal problems from the name shown on software to the sensor. The                                 connectors shown are JST PHD-18VS which are easily sourced from digikey if replacements                         are required.     EMOTIV EPOC Flex Manual 7 of 15
 Charging and LED Indicators  The EPOC Flex has a single RGB LED to indicate power on and charging as shown in the table                                     below.   Action LED Colour Power OFF / Battery Flat OFF Powered On BLUE USB connected / Charging ORANGE Charge complete GREEN Firmware failure Fade On - Fade Off Blue USB connected / powered On WHITE  It is recommended that your headset is fully charged prior to taking recordings. The charge time                               depends on the remaining capacity in the Lithium Polymer cell and can take up to four hours. If                                   the EPOC Flex LED does not turn blue on power on it requires charging. Please use the                                 provided USB Micro-B cable to recharge using any usb port.  Note 1: The headset will charge faster if connected to a dedicated USB port.  Note 2: If the headset it heavily depleted or hasn’t been used for a few months, leave it                                   connected for 24hrs.        EMOTIV EPOC Flex Manual 8 of 15
 Electrode Assemblies Emotiv has developed the EPOC Flex to use EasyCap Multi-rode gel sensors that are                           pre-configured and easy to setup. The electrodes are attached to 150mm of tinsel wire and                             terminated with JST gold plated crimps. This length is designed to be long enough to reach any                                 position on the cap.   Electrodes are colour coded, blue for left, red for right and black for references. In addition each                                 sensor will be individually labelled with the channel name connected. The aim of this colour                             coding is simple, when troubleshooting you can quickly identify the colour and channel name in                             the software and quickly find the electrode on the cap.  There will be excess wire once the cap is fitted, we recommend that you place a cap over the                                     top to stop these wires catching. If your research involves minimising motion artifacts keeping                           the excess wire secured will be required, either by tidying down the wire or feeding through                               adjacent empty holes. If a cap with electrode leads cut to length is required please contact us.   We know that researchers can have different needs for references, so we have included                           earclips and adhesive pads that fit the electrodes.   Example Electrode placement Below is an example image showing the electrode placement as per the initial setup in EmotivPRO. This placement gives good coverage of the entire head, with the pod fitted in the back pocket.  EMOTIV EPOC Flex Manual 9 of 15
    EMOTIV EPOC Flex Manual 10 of 15
 EPOC Flex Cap   The standard EPOC Flex cap follows the official 10-20 system and has 72 openings as shown                               above. The controller has two pockets it can be placed in on the cap, one is fitted about Cz and                                       the other Iz.   The caps can be ordered in our standard sizes are 54, 56 and 58 cm in a black high comfort                                       material in a caucasian cut. Other sizes, hole positions, materials and cuts are available please                             contact online support for further information.   EMOTIV EPOC Flex Manual 11 of 15
 Specifying Cap Size  Specifying the right cap size is critical for keeping for ensuring the sensors are in the right place when taking measurements. Our supplier recommends measuring the head diameter in the horizontal circumference as shown in the image below.   Once you have the measurement for your test subjects you specify the closest size to the ones available for example 54.5cm → 54cm, 59cm → 58cm, etc. If you need larger or smaller sizes please contact support.     EMOTIV EPOC Flex Manual 12 of 15
 Package Contents  When you receive your order you will find a package that looks like this:  <White Box >   With this shipping box will be the EPOC Flex Package  <Image>   Please note if you order more than one cap or electrode set these will be in the shipping box.  EPOC Flex is designed to allow users to buy the components required to meet their research                               need. When you open the box you will find the following:   1. Controller 2. Universal USB Receiver (included with         Controller)   3. EasyCap Emotiv Custom Cap 4. Electrode Sensors EMOTIV EPOC Flex Manual 13 of 15
  <IMAGE> 5. Micro-B to A USB cable Earclips + adhesive pads     EMOTIV EPOC Flex Manual 14 of 15
 Assembly Quick Start  We recommend that you use a polystyrene head when setting up the cap as this will make                                 setup easier. 1.  Remove the cap, electrode trees and controller from the packaging. 2. Fit the controller to the cap with the emotiv logo as pictured above. 3. Fit the blue wire tree into the left side of the controller and the red wire tree into the right                                       side.  4. Starting with LA position your sensors into the cap, we recommend that you try to keep                               left and right as a mirror image to make setup simple. See our example layout above. 5. The cap is now ready for fitting onto the test subject.  6. Please plug in the universal USB receiver into your computer and ensure the power                           switch is to the right a blue LED will turn on indicating power on. You should also see the                                     lights on the receiver change to indicate it is receiving data.   Cleaning and Maintenance       EMOTIV EPOC Flex Manual 15 of 15

Navigation menu