EnOcean PTM330U 902.875MHz transmitter User Manual users manual

EnOcean GmbH 902.875MHz transmitter users manual

users manual

Download: EnOcean PTM330U 902.875MHz transmitter User Manual users manual
Mirror Download [FCC.gov]EnOcean PTM330U 902.875MHz transmitter User Manual users manual
Document ID1996655
Application IDl8IQO7iT5vyd2wY8HyOObw==
Document Descriptionusers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize88.17kB (1102096 bits)
Date Submitted2013-06-20 00:00:00
Date Available2013-06-20 00:00:00
Creation Date2013-05-16 11:31:23
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2013-05-16 11:31:23
Document Titleusers manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Dr. Wolfgang Heller

USER MANUAL
V1.2
Transmitter Module
PTM 33x / PTM 33xC / PTM 330U
May 16, 2013
Observe precautions! Electrostatic sensitive devices!
Patent protected:
WO98/36395, DE 100 25 561, DE 101 50 128,
WO 2004/051591, DE 103 01 678 A1, DE 10309334,
WO 04/109236, WO 05/096482, WO 02/095707,
US 6,747,573, US 7,019,241
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2
May 16, 2013 1:31 PM
Page 1/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
REVISION HISTORY
The following major modifications and improvements have been made to the first version of
this document:
No
0.81
0.85
0.90
1.00
1.01
1.02
1.03
1.10
1.2
Major Changes
CFG Pin: For test purposes only
Antenna length 868 MHz changed to 86 mm; upper limit of operating temperature
reduced to 65 °C
Equivalent energy pulse definition added
Max. supply voltage for programming interface added in 2.4. Digital input parameters added in 2.3. FCC / IC grants added in 4.2 and 4.3.
TX power increased to 3 dBm at antenna input; Chapter Related Documents added; misleading table removed in 3.3
Figure corrected in 3.4
3.4 modified
Meander structures increased; PTM 330U added
Included certification information for PTM 330U
Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany
www.enocean.com, info@enocean.com, phone ++49 (89) 6734 6890
© EnOcean GmbH
All Rights Reserved
Important!
This information describes the type of component and shall not be considered as assured
characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry
and specifications are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com.
As far as patents or other rights of third parties are concerned, liability is only assumed for
modules, not for the described applications, processes and circuits.
EnOcean does not assume responsibility for use of modules described and limits its liability
to the replacement of modules determined to be defective due to workmanship. Devices or
systems containing RF components must meet the essential requirements of the local legal
authorities.
The modules must not be used in any relation with equipment that supports, directly or
indirectly, human health or life or with applications that can result in danger for people,
animals or real value.
Components of the modules are considered and should be disposed of as hazardous waste.
Local government regulations are to be observed.
Packing: Please use the recycling operators known to you.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 2/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
TABLE OF CONTENT
RELATED DOCUMENTS ................................................................................... 4
2.1
2.2
2.3
2.4
2.5
FUNCTIONAL DESCRIPTION ............................................................................ 7
3.1 Block diagram ............................................................................................... 7
3.2 Pin out ......................................................................................................... 7
3.3 Pin Description and operational characteristics .................................................. 8
3.4 Configuration Interface .................................................................................. 9
3.5 Absolute maximum ratings (non operating) ...................................................... 9
3.6 Maximum Ratings (operating) ....................................................................... 10
3.7 Radio telegram ............................................................................................ 11
3.7.1 Normal operation ..................................................................................... 11
3.7.2 User defined operation ............................................................................. 12
3.8 Transmit timing ........................................................................................... 12
4.1
4.2
4.3
4.4
4.5
4.6
GENERAL DESCRIPTION ................................................................................. 4
Basic Functionality ......................................................................................... 4
Technical Data .............................................................................................. 4
Physical Dimensions....................................................................................... 5
Environmental Conditions ............................................................................... 6
Ordering Information ..................................................................................... 6
APPLICATIONS INFORMATION ....................................................................... 13
How to connect an energy harvester .............................................................. 13
How to generate an equivalent energy pulse ................................................... 13
Antenna ..................................................................................................... 14
Layout recommendations ............................................................................. 15
Soldering information PTM 332/332C ............................................................. 16
Transmission range ..................................................................................... 17
AGENCY CERTIFICATIONS ............................................................................ 18
5.1 CE approval ................................................................................................ 18
5.2 FCC (United States) Certification ................................................................... 19
5.2.1 PTM 330C and PTM 332C FCC LIMITED MODULAR APPROVAL ........................ 19
5.2.2 PTM 330C and PTM 332C FCC LIMITED MODULAR APPROVAL Certificate ......... 21
5.2.3 PTM 330U FCC (United States) Single Transmitter Approval .......................... 22
5.2.4 FCC (United States) Regulatory Statements ............................................... 23
5.3 IC (Industry Canada) Certification ................................................................. 24
5.3.1 PTM 330C and PTM 332C IC (Industry Canada) Certification ......................... 24
5.3.2 PTM 330C / PTM 332C Industry Canada Certification Document ..................... 25
5.3.3 PTM 330U IC (Industry Canada) Certification .............................................. 26
5.3.4 Industry Canada Regulatory Statements ..................................................... 27
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 3/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
RELATED DOCUMENTS
In addition to this document additional information is available on our web site:
 Proposal for mechanical integration with ECO 200 in 2D and 3D format
 Footprint with positions of pads available in Protel and Gerber format
 AN102: Antenna Basics – Basic antenna design considerations for EnOcean based products
GENERAL DESCRIPTION
2.1
Basic Functionality
The radio transmitter module PTM 330 from EnOcean enables the implementation of wireless sensors and switches
without batteries.
Key applications are handheld remote controls or industrial
switches.
Functional Principle
When an energy pulse is supplied (e.g. by ECO 200 from
EnOcean) an RF telegram is transmitted including a unique
32-bit module ID, the polarity of the energy pulse, and the operating status of 4 digital inputs. The RPS telegram content can be configured if other content is needed.
PTM 330 can be connected to ECO 200 via a contact spring. There are two meander structures on the PCB which allow usage of a rubber pad to set the level of two digital inputs.
Alternatively PTM 330 can be mounted as an SMD component onto a host PCB. In this case
energy supply pins and digital input pins are accessible via contact pads.
Product variants
 PTM 330: 868 MHz variant, pre-installed whip antenna, delivery in card board box
 PTM 332: 868 MHz variant, no pre-installed antenna, delivery as tape & reel
 PTM 330C: 315 MHz variant, pre-installed whip antenna, delivery in card board box
 PTM 332C: 315 MHz variant, no pre-installed antenna, delivery as tape & reel
 PTM 330U: 902 MHz variant, pre-installed whip antenna, delivery in card board box
2.2
Technical Data
Power supply
ECO 200 or equivalent energy pulse
Antenna
pre-installed whip antenna PTM 330/330C/330U
external 50 Ohm or whip antenna PTM 332/332C
Frequency
868.3 MHz (PTM 33x) / 315.0 MHz (PTM 33xC) / 902.875 MHz (PTM 330U)
Transmission power
typ. 3 dBm at antenna base
Data rate / Modulation type
Telegram type
125 kbps / ASK(315MHz, 868MHz), FSK(902MHz)
RPS of type 2 (allows interpretation of operating two buttons simultaneously)
Digital inputs
Transmission range
© 2010 EnOcean | www.enocean.com
up to 200 m free field, up to 30 m indoor
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 4/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
2.3
Physical Dimensions
PCB dimensions
© 2010 EnOcean | www.enocean.com
26.2 x 21.15 x 3.5 mm
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 5/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
2.4
Environmental Conditions
Operating temperature
-25 °C … +65 °C
Storage temperature
-40 °C … +85 °C
Storage temperature in Tape&Reel
-20 °C … +50 °C
Humidity
2.5
0% … 93% r.h., non-condensing
Ordering Information
Type
Ordering Code
PTM 330
S3001-A330
PTM 332
S3001-A332
PTM 330C
S3031-A330
PTM 332C
S3031-A332
PTM 330U
S3051-A330
© 2010 EnOcean | www.enocean.com
Frequency
868.3 MHz
868.3 MHz
315.0 MHz
315.0 MHz
902.875 MHz
Note
Whip antenna mounted
Card board box
No antenna mounted
Tape & Reel
Whip antenna mounted
Card board box
No antenna mounted
Tape & Reel
Whip antenna mounted
Card board box
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 6/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
FUNCTIONAL DESCRIPTION
3.1
Block diagram
At power-up by an energy pulse at AC1, AC2 a DC voltage is provided to the internal micro
controller. The microcontroller reads the polarity of the supply voltage pulse and the status
of the digital inputs A0, A1, B0, B1. After that 3 identical radio telegrams calculated from
the status of these inputs are transmitted.
PTM33x
CFG
A0
A1
RF_WHIP
B0
µC
B1
RF
GND
GND
3.2
RF_50
Polarity
Detection
Pin out
AC1
AC2
GND
CFG
B0
GND
B1
A0
GND
© 2010 EnOcean | www.enocean.com
A1
Power
Converter
AC1
AC2
T1
T4
T3
T8
T6
AC2
T5
T2
16
AC1
15
AC2
14
GND
13
V+
12
GND
11
RF_50
10
GND
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 7/27
T7
T9
AC1
RF_WHIP
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
3.3
Pin Description and operational characteristics
Symbol
Function
Characteristics
GND
V+
Ground connection
For test purposes only
O-Button Rocker B
Must be connected to GND
Do not connect
Digital input, leave open or connect to GND
Internal pull-up
Digital input, leave open or connect to GND
Internal pull-up
Digital input, leave open or connect to GND
Internal pull-up
Digital input, leave open or connect to GND
Internal pull-up
Internal pull-up
ECO 200 or equivalent energy pulse
ECO 200 or equivalent energy pulse
Output for whip antenna
50 Ohm output for external antenna, not available for PTM 330U
See 3.4
B0
I-Button Rocker B
B1
O-Button Rocker A
A0
I-Button Rocker A
A1
CFG
AC1
AC2
RF_WHIP
RF_50
For test purposes only
Input for ECO 200
Input for ECO 200
RF output
RF output
T1-9
Configuration Interface
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 8/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
3.4
Configuration Interface
Via the programming interface the telegram content can be modified.
The interface is shown in the figure below:
USB
USB <= > SPI
interface
Reset
PROG_EN
ADIO7
SCSEDIO0
SCLKDIO1
WSDADIO2
RSDADIO3
SPI
Dolphin Studio, or EOPx
PTM 330
PTM
EnOcean provides EOPx (EnOcean Programmer, a command line program) and Dolphin
Studio (Windows application for chip configuration, programming, and testing) and the
USB/SPI programmer device as part of the EDK 300 developer’s kit. In order to contact
PTM 330 programming and testing points a needle bed adapter is needed.
Pad
Symbol
Function
Characteristics
T1
T2
T3
T4
T5
T6
VDD
GND
SCSEDIO0
SCLKDIO1
WSDADIO2
RSDADIO3
RESET
Supply voltage
Ground connection
SPI chip select
SPI serial clock
SPI input
SPI output
Reset
Interface
Interface
Interface
Interface
Interface
Interface
Interface
down
ADIO7
Sync output
T7
T8
T9
3.5
PROG_EN
Enable programming mode
to
to
to
to
to
to
to
programmer; Max. 3.3 V
programmer
programmer
programmer
programmer
programmer
programmer, internal pull
Interface to programmer
HIGH: programming mode active
LOW: operating mode
Internal pull-down
Absolute maximum ratings (non operating)
Symbol
AC1
AC2
GND
A0
A1
B0
B1
Parameter
Supply voltage
Ground connection
Min
Max
6.4
Units
Voltage digital input pins
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 9/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
3.6
Maximum Ratings (operating)
Symbol
AC1
AC2
GND
A0
A1
B0
B1
Parameter
Supply voltage
Ground connection
Min
Max
6.0
Units
Voltage digital input pins
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 10/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
3.7
Radio telegram
3.7.1 Normal operation
In default configuration PTM 33x transmits the same telegrams as a PTM 200 radio switch:




Telegram type RPS: There are two message types depending on how many buttons
(A0, A1, B0, B1) have been pressed (connected to GND)
o N-message: Only one or two buttons have been pressed.
o U-message: No pushbutton was pressed when activating the energy generator, or more than two pushbuttons have been pressed.
Unique factory programmed 32 bit ID
DATA_BYTE2, DATA_BYTE1, DATA_BYTE0=0
DATA_BYTE3 and STATUS as follows:
N-message:
DATA_BYTE3:
RID
UD
RID
UD
PO
SRID
SUD
SA
PR
(2
(1
(1
(2
(1
(1
bit)
bit)
bit)
bit)
bit)
bit)
SRID
SUD
SA
Rocker ID, A=0, B=1
UD=1  O-button, UD=0  I-button
Polarity, see table below
Second Rocker ID
(Second) SUD=1  O-button, SUD=0  I-button
SA=1  Second action (2 buttons pressed
simultaneously), SA=0  No second action
STATUS:
Reserved
T21
Reserved
T21
NU
RP_COUNTER
NU
(2
(1
(1
(4
bit)
bit)
bit)
bit)
© 2010 EnOcean | www.enocean.com
RP_COUNTER
For future use
NU=1  N-message.
Repeater level: 0 is original message (not repeated)
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 11/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
U-message:
DATA_BYTE3:
BUTTONS
BUTTONS
PR
Reserved
(3 bit)
Number of simultaneously pressed buttons, as following:
0 = 0 Button
1 = not possible
2 = not possible
3 = 3 or 4 buttons
4 = not possible
5 = not possible
6 = not possible
7 = not possible
PO
Reserved
(1 bit)
(4 bit)
Polarity, see table below
STATUS:
Reserved
T21
Reserved
T21
NU
RP_COUNTER
NU
(2
(1
(1
(4
RP_COUNTER
bit)
bit)
bit)
bit)
For future use
NU=0  U-message.
Repeater level: 0 is original message (not repeated)
The polarity PO is defined as follows:
AC1
AC2
PO
3.7.2 User defined operation
Via the configuration interface it is possible to define different content of DATA_BYTE3 and
define if a N-message or U-message shall be sent. This allows for example to transmit
other RORG=F6 telegrams, e.g. “Mechanical handle”, as described in the EnOcean Equipment Profiles defined by EnOcean Alliance.
For details please refer to the EnOcean Equipment Profiles 2.1 specification.
http://www.enocean-alliance.org/fileadmin/redaktion/enocean_alliance/pdf/EnOcean_Equipment_Profiles_EEP2.1.pdf
3.8
Transmit timing
The setup of the transmission timing allows avoiding possible
of other EnOcean transmitters as well as disturbances from
transmission cycle, 3 identical subtelegrams are transmitted
sion of a subtelegram lasts approximately 0.7 ms. The delay
sion bursts is affected at random.
© 2010 EnOcean | www.enocean.com
collisions with data packages
the environment. With each
within 40 ms. The transmisbetween the three transmis-
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 12/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
APPLICATIONS INFORMATION
4.1
How to connect an energy harvester
PTM 330 can be connected to ECO 200 without soldering. ECO
200 provides contact springs which can directly be connected
to contact pads of PTM 330. The contact pads on the bottom of
the PCB are shown below (left). A second orientation where
PTM 330 is rotated 180° with respect to ECO 200 is also possible as shown with dashed lines.
4.2
How to generate an equivalent energy pulse
PTM330 can also be operated from an external equivalent energy pulse.
As the source impedance is not known a procedure is defined how to find the needed duration of the pulse.
The pulse must provide a voltage between 5 V and 6 V for maximum 10 ms time.
storage capacitor
The length of this supply pulse needs to be defined by measuring the remaining voltage on
the storage capacitor after the 3rd subtelegram, according to the following procedure:
1) Discharge the storage capacitor (see photo) completely
2) Apply a short pulse, voltage between 5 V to 6 V which charges the capacitor
3) Measure the voltage drop at the storage capacitor to ground (between pin 13 and
pin 12) while the sub-telegrams are being transmitted with an oscilloscope
4) The remaining voltage shortly after the 3rd sub-telegram should be 2.5 to 3.0 V
1st
2nd
3rd
2.5-3.0V
10
© 2010 EnOcean | www.enocean.com
15
20
25
30
35
40
ms
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 13/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
4.3
Antenna
315 MHz
Option 1: 150 mm wire, connect to RF_WHIP
Option 2: A 50 Ω antenna can be connected to RF_50.
In this case the limited modular FCC/IC approval is not valid!
An FCC/IC approval is then needed for the end device!
868 MHz
Option 1: 86 mm wire, connect to RF_WHIP
Option 2: A 50 Ω antenna can be connected to RF_50
902 MHz
64 mm wire, connect to RF_WHIP
Specification of the whip antenna; L=150 mm @ 315 MHz,
L=86 mm @ 868 MHz, L=64 mm @ 902 MHz
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 14/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
4.4
Layout recommendations
Proposal for foot print on host PCB
Keep out area on host PCB. No copper surface area allowed!
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 15/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
4.5
Soldering information PTM 332/332C
PTM 332 has to be soldered according to IPC/JEDEC J-STD-020C standard.
PTM 332 shall be handled according to Moisture Sensitivity Level MSL4 which means a floor
time of 72 h. PTM 332 may be soldered only once, since one time is already consumed at
production of the module itself.
Once the dry pack bag is opened, the desired quantity of units should be removed and the
bag resealed within two hours. If the bag is left open longer than 30 minutes the desiccant
should be replaced with dry desiccant. If devices have exceeded the specified floor life time
of 72 h, they may be baked according IPC/JEDEC J-STD-033B.
Devices packaged in moisture-proof packaging should be stored in ambient conditions not
exceeding temperatures of 40 °C or humidity levels of 90% r.h.
PTM 332 modules have to be soldered within 6 months after delivery!
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 16/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
4.6
Transmission range
The main factors that influence the system transmission range are type and location of the
antennas of the receiver and the transmitter, type of terrain and degree of obstruction of
the link path, sources of interference affecting the receiver, and “Dead” spots caused by
signal reflections from nearby conductive objects. Since the expected transmission range
strongly depends on this system conditions, range tests should categorically be performed
before notification of a particular range that will be attainable by a certain application.
The following figures for expected transmission range are considered by using a PTM, a
STM or a TCM radio transmitter device and the TCM radio receiver device with preinstalled
whip antenna and may be used as a rough guide only:





Line-of-sight connections: Typically 30 m range in corridors, up to 100 m in halls
Plasterboard walls / dry wood: Typically 30 m range, through max. 5 walls
Line-of-sight connections: Typically 30 m range in corridors, up to 100 m in halls
Ferroconcrete walls / ceilings: Typically 10 m range, through max. 1 ceiling
Fire-safety walls, elevator shafts, staircases and supply areas should be considered as
screening.
The angle at which the transmitted signal hits the wall is very important. The effective wall
thickness – and with it the signal attenuation – varies according to this angle. Signals
should be transmitted as directly as possible through the wall. Wall niches should be
avoided. Other factors restricting transmission range:
 Switch mounted on metal surfaces (up to 30% loss of transmission range)
 Hollow lightweight walls filled with insulating wool on metal foil
 False ceilings with panels of metal or carbon fiber
 Lead glass or glass with metal coating, steel furniture
The distance between EnOcean receivers and other transmitting devices such as computers, audio and video equipment that also emit high-frequency signals should be at least
0.5 m
A summarized application note to determine the transmission range within buildings is
available as download from www.enocean.com.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 17/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
AGENCY CERTIFICATIONS
The modules have been tested to fulfil the approval requirements for CE (PTM 33x) and
FCC/IC (PTM 33xC, PTM 330U) based on the built-in firmware.
5.1
CE approval
The modules bear the EC conformity marking CE and conform to the R&TTE EU-directive on
radio equipment. The assembly conforms to the European and national requirements of
electromagnetic compatibility. The conformity has been proven and the according documentation has been deposited at EnOcean. The modules can be operated without notification and free of charge in the area of the European Union, and in Switzerland. The following
provisos apply:
EnOcean RF modules must not be modified or used outside their specification
limits.
EnOcean RF modules may only be used to transfer digital or digitized data.
Analog speech and/or music are not permitted.
The final product incorporating EnOcean RF modules must itself meet the essential requirement of the R&TTE Directive and a CE marking must be affixed
on the final product and on the sales packaging each. Operating instructions
containing a Declaration of Conformity has to be attached.
If the transmitter is used according to the regulations of the 868.3 MHz band,
a so-called “Duty Cycle” of 1% per hour must not be exceeded. Permanent
transmitters such as radio earphones are not allowed.
The module must be used with only the following approved antenna(s).
Type
Parameter
Value
Wire/Monopole at RF_WHIP Maximum gain
1.0 dBi
External antenna at RF_50
Antenna type
Passive
Impedance
~50 Ohm
Maximum gain
≤ 0 dBd
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 18/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.2
FCC (United States) Certification
5.2.1 PTM 330C and PTM 332C FCC LIMITED MODULAR APPROVAL
This is an RF module approved for Limited Modular use operating as an intentional transmitting device with respect to 47 CFR 15.231(a-c) and is limited to OEM installation.
The module is optimized to operate using small amounts of energy, and may be powered
by a battery.
The module transmits short radio packets comprised of control signals, (in some cases the
control signal may be accompanied with data) such as those used with alarm systems, door
openers, remote switches, and the like.
The module does not support continuous streaming of voice, video, or any other forms of
streaming data; it sends only short packets containing control signals and possibly data.
The module is designed to comply with, has been tested according to 15.231(a-c), and has
been found to comply with each requirement.
Thus, a finished device containing the PTM 330C/PTM 332C/PTM 330U radio module can be
operated in the United States without additional Part 15 FCC approval (approval(s) for unintentional radiators may be required for the OEM’s finished product), under EnOcean’s FCC
ID number.
This greatly simplifies and shortens the design cycle and development costs for OEM integrators. The module can be triggered manually or automatically, which cases are described
below.
Manual Activation
The radio module can be configured to transmit a short packetized control signal if triggered manually. The module can be triggered, by pressing a switch, for example.
The packet contains one (or more) control signals that is(are) intended to control something at the receiving end. The packet may also contain data.
Depending on how much energy is available from the energy source, subsequent manual
triggers can initiate the transmission of additional control signals. This may be necessary if
prior packet(s) was(were) lost to fading or interference. Subsequent triggers can also be
initiated as a precaution if any doubt exists that the first packet didn’t arrive at the receiver.
Each packet that is transmitted, regardless of whether it was the first one or a subsequent
one, will only be transmitted if enough energy is available from the energy source.
Automatic Activation
The radio module also can be configured to transmit a short packetized control signal
if triggered automatically. Again, the packet contains a control signal that is intended to
control something at the receiving end and may also contain data.
As above, it is possible for the packet to get lost and never reach the receiver. However, if
enough energy is available from the energy source, and the module has been configured to
do so, then another packet or packets containing the control signal may be transmitted at a
later time.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 19/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
OEM Requirements
In order to use EnOcean’s FCC ID number, the OEM must ensure that the following conditions are met:

End users of products, which contain the module, must not have the ability to alter the
firmware that governs the operation of the module. The agency grant is valid only when
the module is incorporated into a final product by OEM integrators.

The end-user must not be provided with instructions to remove, adjust or install the
module.

The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. This includes a clearly visible label on the outside of the final product.
Attaching a label to a removable portion of the final product, such as a battery cover, is
not permitted. The label must include the following text:
PTM330C/PTM332C
Contains FCC ID: SZV-PTM33XC
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (i.) this device may not cause harmful interference and
(ii.) this device must accept any interference received, including interference that
may cause undesired operation.
When the device is so small or for such use that it is not practicable to place the statement above on it, the information required by this paragraph shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be placed on the container in which the device is marketed. However, the FCC
identifier or the unique identifier, as appropriate, must be displayed on the device.
The user manual for the end product must also contain the text given above.

The module must be used with only the following approved antenna(s).
Part Number
N.A.
Type
Wire/Monopole
Gain
1.0 dBi

The OEM must ensure that timing requirements according to 47 CFR 15.231(a-c) are
met.

The OEM must sign the OEM Limited Modular Approval Agreement with EnOcean
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 20/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.2.2 PTM 330C and PTM 332C FCC LIMITED MODULAR APPROVAL Certificate
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 21/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.2.3 PTM 330U FCC (United States) Single Transmitter Approval
PTM 330U is an RF module approved by the FCC as Single Transmitter with the following
ID:
FCC ID:
SZV-PTM330U
The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements
are met. This includes a clearly visible label on the outside of the final product. Attaching a
label to a removable portion of the final product, such as a battery cover, is not permitted.
The label must include the following text:
PTM330U
Contains FCC ID: SZV-PTM330U
The enclosed device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (i.) this device may not cause harmful interference and
(ii.) this device must accept any interference received, including interference that
may cause undesired operation.
When the device is so small or for such use that it is not practicable to place the statement
above on it, the information required by this paragraph shall be placed in a prominent location in the instruction manual or pamphlet supplied to the user or, alternatively, shall be
placed on the container in which the device is marketed. However, the FCC identifier or the
unique identifier, as appropriate, must be displayed on the device.
The user manual for the end product must also contain the text given above.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 22/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.2.4 FCC (United States) Regulatory Statements
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by manufacturer could void the
user’s authority to operate the equipment.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
Consult the dealer or an experienced radio/ TV technician for help.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 23/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.3
IC (Industry Canada) Certification
5.3.1 PTM 330C and PTM 332C IC (Industry Canada) Certification
PTM 330C and PTM 332C have been granted an IC number as outlined below:
IC:
5713A-PTM33XC
In order to use EnOcean’s IC number, the OEM must ensure that the following conditions
are met:
Labeling requirements for Industry Canada are similar to those required by the FCC.
The Original Equipment Manufacturer (OEM) must ensure that IC labeling requirements are
met. A clearly visible label on the outside of a non-removable part of the final product must
include the following text:
PTM 330C / PTM 332C:
Contains IC: 5713A-PTM33XC
The OEM must sign the OEM Limited Modular Approval Agreement with EnOcean.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Pour utiliser le numéro IC EnOcean, le OEM doit s'assurer que les conditions suivantes sont
remplies:

Les exigences d'étiquetage pour Industrie Canada sont similaires à ceux exigés par la
FCC. Le fabricant d'équipement d'origine (OEM) doit s'assurer que les exigences en
matière d'étiquetage IC sont réunies. Une étiquette clairement visible à l'extérieur d'une
partie non amovible du produit final doit contenir le texte suivant:
PTM 330C / PTM 332C:
Contains IC: 5713A-PTM33XC
Contient le module d'émission IC: 5713A-PTM33XC
 L'OEM doit signer l'accord OEM limitée Approbation modulaire avec EnOcean
 IMPORTANT! Tous les changements ou modifications pas expressément approuvés par la
partie responsable de la conformité ont pu vider l’autorité de l’utilisateur pour actioner
cet équipment.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 24/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.3.2 PTM 330C / PTM 332C Industry Canada Certification Document
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 25/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.3.3 PTM 330U IC (Industry Canada) Certification
PTM 330U has been granted an IC number as outlined below:
IC:
5713A-PTM330U
Labeling requirements for Industry Canada are similar to those required by the FCC.
The Original Equipment Manufacturer (OEM) must ensure that IC labeling requirements are
met.
A clearly visible label on the outside of a non-removable part of the final product must include the following text:
PTM 330U:
Contains IC: 5713A-PTM330U
Pour utiliser le numéro IC EnOcean, le OEM doit s'assurer que les conditions suivantes sont
remplies:
Les exigences d'étiquetage pour Industrie Canada sont similaires à ceux exigés par la FCC.
Le fabricant d'équipement d'origine (OEM) doit s'assurer que les exigences en
matière d'étiquetage IC sont réunies.
Une étiquette clairement visible à l'extérieur d'une partie non amovible du produit final doit
contenir le texte suivant:
PTM 330U:
Contains IC: 5713A-PTM330U
Contient le module d'émission IC: 5713A-PTM330U
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 26/27
USER MANUAL
V1.2
PTM 33X / PTM 33XC / PTM 330U
5.3.4 Industry Canada Regulatory Statements
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: (1) this device may not cause interference, and (2)
this device must accept any interference, including interference that may cause undesired
operation of the device.
IMPORTANT! Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
This Class B digital apparatus complies with Canadian ICES-003.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes: (1)
l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter
tout brouillage radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement.
IMPORTANT! Tous les changements ou modifications pas expressément approuvés par la
partie responsable de la conformité ont pu vider l’autorité de l’utilisateur pour actioner cet
équipment.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
© 2010 EnOcean | www.enocean.com
PTM 33x / PTM 33xC / PTM 330U User Manual V1.2 | Page 27/27

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 27
Language                        : de-DE
Tagged PDF                      : Yes
Author                          : Dr. Wolfgang Heller
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2013:05:16 11:31:23
Modify Date                     : 2013:05:16 11:31:23
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SZV-PTM330U

Navigation menu