EnOcean STM350U Temperature and Humidity Sensor with transmitter User Manual

EnOcean GmbH Temperature and Humidity Sensor with transmitter

User Manual

Download: EnOcean STM350U Temperature and Humidity Sensor with transmitter User Manual
Mirror Download [FCC.gov]EnOcean STM350U Temperature and Humidity Sensor with transmitter User Manual
Document ID3734137
Application IDFYGPvUoLl5ok++IOXr7/Vg==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize32.78kB (409807 bits)
Date Submitted2018-01-30 00:00:00
Date Available2018-01-30 00:00:00
Creation Date2017-12-28 14:11:01
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2017-12-28 14:11:01
Document TitleUser Manual
Document CreatorMicrosoft® Word 2010
Document Author: Matthias Kassner

USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
ETHSU Easyfit Temperature and Humidity Sensor
21.12.2017
Observe precautions! Electrostatic sensitive devices!
Patent protected:
WO98/36395, DE 100 25 561, DE 101 50 128,
WO 2004/051591, DE 103 01 678 A1, DE 10309334,
WO 04/109236, WO 05/096482, WO 02/095707,
US 6,747,573, US 7,019,241
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 1/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
REVISION HISTORY
The following major modifications and improvements have been made to this document:
Version
1.0
Author
MKA
Reviewer
MKA
Date
22.12.2017
Major Changes
First release
Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany
www.enocean.com, info@enocean.com, phone +49 (89) 6734 6890
© EnOcean GmbH, All Rights Reserved
Other trademarks and trade names are those of their respective owners.
Important!
This information describes the type of component and shall not be considered as assured
characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry
and specifications are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com.
As far as patents or other rights of third parties are concerned, liability is only assumed for
modules, not for the described applications, processes and circuits.
EnOcean does not assume responsibility for use of modules described and limits its liability
to the replacement of modules determined to be defective due to workmanship. Devices or
systems containing RF components must meet the essential requirements of the local legal
authorities.
The modules must not be used in any relation with equipment that supports, directly or
indirectly, human health or life or with applications that can result in danger for people,
animals or real value.
Components of the modules are considered and should be disposed of as hazardous waste.
Local government regulations are to be observed. Packing: Please use the recycling operators known to you.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 2/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
TABLE OF CONTENT
RELATED DOCUMENTS ................................................................................... 4
GENERAL DESCRIPTION ................................................................................. 5
2.1 Basic functionality ......................................................................................... 5
2.2 Technical Data .............................................................................................. 6
2.3 Environmental conditions ............................................................................... 6
2.4 Ordering Information ..................................................................................... 6
2.5 Physical dimensions ....................................................................................... 7
2.5.1 Mechanical Outline..................................................................................... 7
FUNCTIONAL DESCRIPTION ............................................................................ 8
3.1 Simplified firmware flow chart ......................................................................... 8
3.2 Simplified device block diagram ...................................................................... 9
3.3 Radio telegram format ................................................................................... 9
3.3.1 Teach-in telegram ..................................................................................... 9
3.3.2 Transmit timing ......................................................................................... 9
Application Information ................................................................................ 10
4.1 Transmission range ..................................................................................... 10
5.1
5.2
5.3
5.4
Regulatory information................................................................................. 11
FCC (United States) Certificate ...................................................................... 12
FCC (United States) Regulatory Statement ..................................................... 12
IC (Industry Canada) Certificate .................................................................... 13
IC (Industry Canada) Regulatory Statement ................................................... 13
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 3/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
RELATED DOCUMENTS
This document describes operation of ETHSU modules with their built-in firmware.
We recommend following our application notes, in particular AN001: EnOcean Wireless Systems – RANGE PLANNING GUIDE, AN002: RANGE EXTENSION WITH ENOCEAN Concept design of extending range with EnOcean networks and AN010: Short-Range Devices, Indoor Radio Propagation.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 4/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
GENERAL DESCRIPTION
2.1
Basic functionality
EnOcean EasyFit ETHSU is a wireless and maintenance
free temperature and humidity sensor. It requires no
external components and provides on-board a calibrated temperature and humidity sensor.
Power supply is provided by a small pre-installed solar
cell or an external 3 V backup battery.
An energy storage element is installed in order to
bridge periods with no supply from the energy harvester.
The module provides an internal cyclic wake up every
100s. After wake up, the internal microcontroller reads
the status of the temperature and humidity sensor. A
radio telegram will be transmitted in case of a significant change of measured temperature or measure humidity.
In case of no relevant input change, a redundant retransmission signal (heartbeat) is sent
randomly within 8 to 15 minutes to announce the current values.
In addition to the cyclic wake-up, a wake up can be triggered externally using the input for
the occupancy button or the internal LRN button.
Key product features
 Fully autonomous operation under sufficient lighting with pre-installed solar cell
 Factory calibrated on-board temperature and humidity sensor
 Integrated energy storage and charging circuit
 Integrated LRN button and TX indicator LED
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 5/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
2.2
Technical Data
Antenna
Frequency
Data rate/Modulation type
Radiated Output Power (typ.)
On-board Power Supply
Auxiliary Power Supply
Operation time in darkness @ 25°C
Start-up time from empty energy store
Input parameters
Temperature sensor performance
Humidity sensor performance
Measurement range:
Resolution:
Accuracy:
Measurement range:
Resolution:
Accuracy:
EnOcean Equipment Profile
2.3
Helix antenna
902.875 MHz
125 kbps / FSK
100 dBμV/m
Pre-installed solar cell
Illumination 50-100000 lux
Option for backup battery (CR1225)
typ. 4 days after full charge
typ. < 5 min @ 400 lux / 25 °C
incandescent or fluorescent light
Temperature and humidity sensor
LRN button
-20°C … +60 °C
0.1 K
±0.5 K across entire range
0 % r.h. … 100 % r.h.
0.4 % r.h.
±4.5 % r.h. across entire range
±3.0 % r.h. between 20 … 80 % r.h.
A5-04-03
Environmental conditions
Operating and Storage temperature
Absolute Maximum: -20 °C … +60 °C
Recommended1: +10 °C…+30 °C
36 months after delivery2
Shelf life (in absolute darkness)
Operating and storage humidity
Maximum: 0% … 93% r.h., non-condensing
Recommended: < 60% r.h.
The module shall not be placed on conductive materials, to prevent discharge of
the internal energy storages. Even materials such as conductive foam (ESD protection) may have negative impact.
2.4
Ordering Information
Type
ETHSU
Ordering Code
S3051-D350
Frequency
902.875MHz
Recommended for maximum life of energy storage capacitor
Deep discharge of the energy storage leads to degradation of performance. Therefore
products have to be taken into operation after 36 months.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 6/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
2.5
Physical dimensions
Product dimensions
87±1 x 21±1 x 14±1 mm
Product weight
25 g
2.5.1 Mechanical Outline
Detailed drawings are available from EnOcean.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 7/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
FUNCTIONAL DESCRIPTION
3.1
Simplified firmware flow chart
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 8/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
3.2
Simplified device block diagram
3.3
Radio telegram format
ETHSU transmits telegram data according to EEP (EnOcean Equipment Profile) A5-04-03
which encodes a temperature range of Temperature -20 ... 60°C with 10 Bit and a Humidity
range of 0 ... 100 % r.h.
with 8 Bit.
3.3.1 Teach-in telegram
If the user presses the LRN button then the module transmits a teach-in telegram.
With this special teach-in telegram it is possible to identify the manufacturer of a device
and the function and type of a device via the EEP or GP used.
By default EnOcean Manufacturer ID is set. Customers should configure the module to use
their own Manufacturer ID.
3.3.2 Transmit timing
The setup of the transmission timing allows avoiding possible collisions with data packages
of other EnOcean transmitters as well as disturbances from the environment.
With each default transmission cycle, 3 identical sub-telegrams are transmitted within
40ms. Transmission of a sub-telegram lasts approximately 1.2ms. The delay between the
three transmission bursts is affected at random.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 9/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
Application Information
4.1
Transmission range
The main factors that influence the system transmission range are type and location of the
antennas of the receiver and the transmitter, type of terrain and degree of obstruction of
the link path, sources of interference affecting the receiver, and “Dead” spots caused by
signal reflections from nearby conductive objects. Since the expected transmission range
strongly depends on this system conditions, range tests should categorically be performed
before notification of a particular range that will be attainable by a certain application.
The following figures for expected transmission range may be used as a rough guide only:
 Line-of-sight connections: Typically 30 m range in corridors, up to 100 m in halls
 Plasterboard walls / dry wood: Typically 30 m range, through max. 5 walls
 Ferroconcrete walls / ceilings: Typically 10 m range, through max. 1 ceiling
 Fire-safety walls, elevator shafts, staircases and supply areas should be considered as
screening.
The angle at which the transmitted signal hits the wall is very important. The effective wall
thickness – and with it the signal attenuation – varies according to this angle. Signals
should be transmitted as directly as possible through the wall. Wall niches should be avoided. Other factors restricting transmission range:
 Switch mounted on metal surfaces (up to 30% loss of transmission range)
 Hollow lightweight walls filled with insulating wool on metal foil
 False ceilings with panels of metal or carbon fiber
 Lead glass or glass with metal coating, steel furniture
The distance between EnOcean receivers and other transmitting devices such as computers, audio and video equipment that also emit high-frequency signals should be at least
0.5 m.
A summarized application note to determine the transmission range within buildings is
available as download from www.enocean.com.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 10/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
Regulatory information
ETHSU has been certified according to FCC (US) and ISED (CA) regulations.
Changes or modifications not expressly approved by EnOcean could void the user's authority to operate the equipment.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 11/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
5.1
FCC (United States) Certificate

5.2
FCC (United States) Regulatory Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may
cause undesired operation.
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure,
the antenna(s) used for this transmitter must be installed to provide a separation distance
of at least 20 cm from all persons and must not be co-located or operating in conjunction
with any other antenna or transmitter
Warning
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Interference
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 12/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
5.3
IC (Industry Canada) Certificate

5.4
5.4.1
IC (Industry Canada) Regulatory Statement
English version
This radio transmitter has been approved by Industry Canada to operate with the antenna
types listed with the maximum permissible gain indicated. Antenna types not included in
this list, having a gain greater than the maximum gain indicated for that type, are strictly
prohibited for use with this device.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is
subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to ICES-003. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.

Consult the dealer or an experienced radio/TV technician for help
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 13/14
USER MANUAL
ETHSU – EASYFIT TEMPERATURE AND HUMIDITY SENSOR
5.4.2
French version
PRUDENCE: Changements ou modifications pourraient annuler le droit de l'utilisateur à utiliser l'équipement non autorisées.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de
sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité
nécessaire à l'établissement d'une communication satisfaisante.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
1. L’appareil ne doit pas produire de brouillage, et
2. L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d’en compromettre le fonctionnement.
Ces limites sont conçues pour fournir une protection raisonnable contre les interférences
nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre
une énergie de radiofréquence et, s'il n'est pas installé et utilisé conformément a ux instructions, il peut causer des interférences nuisibles aux communications radio. Cependant,
il n'existe aucune garantie que des interférences no se produiront pas dans une installation
particulière.
Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision, ce
qui peut être déterminé en mettant l'équipement hors et sous tension, l'utilisateur est encouragé à essayer de corriger l'interférence par une ou plusieurs des mesures suivantes:

Réorienter ou déplacer l'antenne de réception.

Augmentez la distance entre l'équipement et le récepteur.

Connecter l'équipement à une sortie sur un circuit différent de celui sur lequel le récepteur est branché.

Consulter le revendeur ou un technicien radio / télévision expérimenté pour de l'aide
© 2017 EnOcean | www.enocean.com
F-710-017, V1.0
ETHSU User Manual | v1.0 | December 2017 | Page 14/14

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 14
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Matthias Kassner
Creator                         : Microsoft® Word 2010
Create Date                     : 2017:12:28 14:11:01-07:00
Modify Date                     : 2017:12:28 14:11:01-07:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SZV-STM350U

Navigation menu